Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B08-0010 plan index
LANDMARK CONDOMINIUMS LANDMARK CONDOMINIUMS VAIL,COLORADO VAIL,COLORADO � �� O 0 o W� °� W� DESCRIPTION OF MODIFICATIONS: � �� � LANDMARK ND MINIUM SHEET INDEX a t� o� �� SHEET INDEX o o w� o� �� p � O W o~ LL~ DESCRIPTION OF MODIFICATIONS: � Q �a o a W a N Q y� o a W a VA1L, COLOR/1ll0 w o � o —d � 0 GENERAL STRUCTURAL A-000 COVER SHEET • • • • S-000 MATERIAL TAKEOFFS II • A-001A DRAWWG INDEX • • • • • S-001 GENERAL NOTES • • • • A-0018 SITE MAP,SYMBOLS AND ABBREVIATIONS . . . . . S-002 STANDARD CONCRETE DETAILS • • • • A-001C BUILDING PROJECT DATA AND BUILDING CQDE REQUIREMENTS • • S-003 STANDARD COMPOSITE STEEL DETAILS • • • • • A-001D BUILDING PROJECT DATA AND BUILDING CODE REQUIREMENTS S-004 STANDARD STEEL CONNECTION DETAILS • • • DESIGN ARCHITECT INTER/ORS A-001E BUILDING PROJECT DATA AND BUILDWG CODE REQUIREMENTS Q S-005 STANDARD STEEL CONNECTION DETAILS • • • FRITZLEN PIERCE ARCHITECTS TORCHIA ASSOCIATES,INC. A-001 F EGRESS PLANS S-006 LIGHT&GAUGE STANDARD DETAILS • • • 1650 E.Vail Valley Dr., C-� 750 N. Orleans St. TOV-1 TOWN OF VAILCALCULATIONS SETBACK/SITECOVERAGE • • • • • V211, Co 81657 Suite 500 TOV-2 TOWN QF VAIL CALCULATIONS HEIGHT CALCS,DENSITY,SNOW STORAGE • • • • • S-101 KEY PLAN&SOUTH ELEVATION • • • • TOV-3 MALL AND GARAGE LEVEL EXiT DIAGRAMS AND AREA SEPARATION RATINGS • • S-102 MALL LEVEL FOUNDATION PLAN . . . . 970-476-6342 CF11C8g0, IL 60610 TOV-4 FIRSTAND SECOND LEVEL EXIT DIAGRAMSANDAREASEPARATION RATINGS • • S-103 GARAGE LEVELPLAN • • • • . www.vailarchitects.com 312-664-3346 TOV-5 THIRD AND FOURTH LEVEI EXIT DIAGRAMS AND AREA SEPARATION RATINGS • • S-104 FIRST LEVEL PLAN • • • • • www.torchia.com TOV-6 FIFTH AND SIXTH LEVEL EXIT DIAGRAMS AND AREA SEPARATION RATINGS • • S-105 2ND LEVEL PLAN • • • • • TOV-7 SEVENTH LEVEL EXIT DIAGRAMS AND AREA SEPARATION RATINGS • • TOV-8 EIGHTH LEVEL EXIT DIAGRAMS AND AREA SEPARATION RATINGS . S-106 3RD LEVEL PLAN • • • • • ARCHITECT OF RECORD STRUCTURAL ENGINEER TOV-9 ADA STANDARD DETAILS . S-107 4TH LEVEL PLAN • • • • • A. EPSTEIN& SONS INTL.,INC. REDW/NE ENGINEERS 5-108 STH LEVELPLAN • • • • • TOV-10 OVERALL GARAGE CONSTRUCTION STAGING PLAN • 6Q0 W. Fulton 0105 E. Beaver Creek Blvd. TOV-11 OVERALL 1 ST LEVEL CONSTRUCTION STAGING PLAN . S-109 6TH LEVEL PLAN • I • • • • TOV-12 BUILDING SECTIONS S-110 7TH LEVEL PLAN(LdFT&ELEV EQUIP) • • • • . 9th Floor Suite 204A, PO BOX HOOJ S-111 roweR-arH�EVE�Pv�N . Chicago, IL 60661 Avon, Co 81620 S-111T TOWER-8TH LEVEL PLAN • • • • • 312-454-9100 970-748-0711 s-i i2 ROOF PLAN • • • • • www.epstein-isi.com CIVIL S-112T TOWER-ROOF PLAN • • • • • M/E/P& ENGINEER CIVIL ENGINEER c-oi civi�covER sHEEr . . . . S301 BUILDING SECTION • • • • • AEC ALP/NE ENG/NEERING,INC C-02 EXISTING CONDITIONS PLAN . . . . . S-302 BUILDING SECTIONS • • • • • C-03 GRADING PLAN • • • • • S303 BUILDING SECTION . . . • PO Box 8489 34510 Highway 6 C-04 STORM DRAIN AND PHONE PLAN • • • • • S-304 NORTH BUILDING ELEVATION . . . . 40801 US 6&24, Ste 214 Unit A-9, PO BOX 97 C-04A WATER AND SEWER PLAN • • S-305 SOUTH BUI�DING ELEVATION • • • • Avon, CO 8�62� Edwards, Co 81632 C-05 SUB-ORAINAGE PLAN • • • • S-306 ROOF SECTIONS • • • 970-748-8520 970-926-3373 C-06 DETAIL SHEET • • • • C-07 DETAIL SHEET • • S-401 BRACING ELEVATIONS • • • • • LANDSCAPE ARCHITECT FIRE PROTECTION S-402 BRACING ELEVATIONS • • • • • SONESMAC BFPE LANDCAPING S 403 BRACING DETAILS • • • S-404 BRACING DETAILS • . P.O. Box 115 P.O. Box 1068 Avon, Co 81620 Westminster, Co 80Q36 L-1 LANDSCAPING PLAN . . . . . s-5o� FouN�arioN oErAi�s 970-949-6490 303-426-0342 S-502 FOUNDATION DETAILS ARCHITECTURAL S-502 FOUNDATION DETAILS AD-002 MALL LEVEL EXISTING AND DEMOLITION PLAN • • • • • S-511 FLOOR FRAMING DETAILS • • AD-003 GARAGE LEVEL EXISTING AND DEMOLITION PLAN • • • • • S-512 FLOOR FRAMING DETAILS • • AD-004 LEVEL ONE EXISTING AND DEMOLITION PIAN • • • • • S-513 FLOOR FRAMING DETAILS • • AD-005 LEVEL TWO EXISTING AND DEMOLITION PLAN • • • • • S-514 FIOOR FRAMING DETAILS-ENTRY BLDG. • • AD-006 LEVEL THREE EXISTING AND DEMOLITION PLAN • • • • • S-515 DETAILS • • AD-007 LEVEL FOUR EXISTING AND DEMOLITION PLAN • • • • • AD-008 LEVEL FIVE EXISTING AND DEMOLITION PLAN • • • • • S-521T TOWER-ROOF DETAILS • AD-009 LEVEL SIX EXISTING AND DEMOLITION PLAN • . • • • • S-521 ROOF DETAILS • • • AD-010 LEVEL SEVEN EXISTING AND DEMOLITION PLAN • • • • S-522 ROOF DETAILS • • AD-011 LEVEL EIGHT EXISTING AND DEMOLITIQN PLAN . . . 5-523 ROOF DETAILS • • • S-524 ROOF ENLARGED PLANS A-002 OVERALLMALLLEVEL • • • • • S-525 CHIMNEY PLANS AND SECTIONS • • A-003 OVERALL GARAGE LEVEL • • S-526 CHIMNEY PLANS AND SECTIONS • • A-004 OVERALL 1 ST LEVEL FLOOR PLAN • • • S-527 CHIMNEY PLANS AND SECTIONS • • A-005 OVERALL 2ND LEVEL FLOOR PLAN • • • S-528 ROOF DETAILS-ENTRY BUILDING • • A-006 OVERALL 3RD LEVEL FLOOR PLAN • • S-529 ROOF DETAILS-ENTRY BUILDING • • A-007 OVERA�L 4TH�EVEL FIOOR PLAN • A-008 OVERALL 5TH LEVEL FLOOR PLAN • • • S-701 TRUSS ELEVATIONS AND DETAILS • • • • • A-009 OVERALL 6TH LEVEL FLOOR PLAN • • • S-703 ARCH ELEVATIONS AND DETAILS • • A-010 OVERALL 7TH LEVEL FLOOR PLAN • • A-011 OVERALL 8TH LEVEL FLOOR PLAN • • • A-012 OVERALL ROOF PLAN • • • MECHANICAL A-102 ENLARGED MAIL LEVEL FLOOR PLAN • • • • • M-100 MECHANICAL SCHEDULE,IEGEND AND SEQUENCE OF OPERATION . • . A-103 ENLARGED GARAGE LEVEL F�OOR PLAN • • • • • M-101 MECHANICAL SCHEDULES • • • • A-104 ENLARGED FIRST LEVEL FLOOR PLAN • • • • • M-102 MECHANICAL SCHEDU�ES • • • • A-105 ENLARGED 2ND LEVEL FLOOR PLAN • • • • • M-103 HEATING AND DOMESTIC WATER BOILER PIPING DIAGRAM • • • • A-106 ENLARGED 3RD LEVEL FLOOR PLAN • • • • • M-104 SNOWMELT SYSTEM BOILER PIPING DIAGRAM • • A-107 ENLARGED 4TH LEVEL FLOOR PLAN • • • • • M-105 MECHANICAL DETAILS • • A-108 ENLARGED 5TH LEVEL FLOOR PLAN • • • • • A-109 ENLARGED 6TH LEVEL FLOOR PLAN • • • • • M-201 MALL�EVEL MECHANICAL PIPWG&PARTIA�HVAC PLAN • • • • A-110 ENLARGED 7TH LEVEL FLOOR PLAN • • • • • M-202 MECHANICAL SITE,PARTIAL 1 ST LEVEL&MECHANICAL ROOM PLANS I . • • • A-111 ENLARGED STH LEVEL FLOOR PLAN • • • • • M-203 TYPICAL UNITS 51 -57,62-65 HVAC PLANS • • • • • A-112 ENLARGED ROOF PLAN • • • • • M-204 TYPICAL UNIT 61 AND 7TH LEVEL HVAC PLANS • • • • • M-205 4THLEVEL INTERSTITIAL MECHANICAL PIPING AND HVAC PLAN • • • • • A-202 ENLARGED MALL LEVEL RCP • • M-206 5TH LEVEL MECHANICAL PIPWG AND REFRIGERATION PLAN • • • • • A-203 ENLARGED GARAGE LEVEL RCP • • M-207 6TH LEVEL MECHANICAL PIPING AND REFRIGERATION PLAN • • • • • A-204 ENLARGED FIRST LEVEL RCP • • • M-208 7TH LEVEL MECHANICAL PIPING AND REFRIGERATION PLAN • • • • A-205 ENLARGED SECOND LEVEL RCP • • M-209 PARTIAL MALL AND 5TH LEVEL RADIANT HEATING PLAN • • • • A-206 ENLARGED THIRD LEVEL RCP • • • M-210 6TH LEVEL RADIANT HEATING PLAN • • • • A-207 ENLARGED FOURTH LEVEL RCP • • M-211 7TH LEVEL RADIANT AND SNOW MELT PLAN • • • • A-208 ENLARGED FIFTH LEVEL RCP • • • M-212 HVAC ROOF ENLARGED PLAN • • • • • A-209 ENLARGED SIXTH LEVEL RCP • • • A-210 ENLARGED SEVENTH LEVEL RCP • • • M300 MECHANICAL DIAGRAMS AND DETAILS M-301 MECHANICAL DIAGRAMS AND DETAILS A-301 OVERALL BUILDING ELEVATIONS • • • • • M-302 MECHANICALDIAGRAMSANDDETAILS A-401 BUILDING SECTION • • • • A-402 BUILDINGSECTION • • • • A-403 BUI�DINGSECTION . . . . PLUMBING A-404 BUILDING SECTION • • • • P-�00 PLUMBING GENERAL NOTES LEGEND AND SCHEDULE • • • A-405 BUILDING SECTION • • P-101 PLUMBING DETAILS&DIAGRAMS • • A-410 BUILDING ENVELOPE ELEVATIONS,SECTIONSAND DETAILS • • • . P-201 MALL LEVEL SANITARY SEWER AND VENT PLAN • • • • A-411 BUILDING ENVELOPE ELEVATIONS,SECTIONSAND DETAILS . • . • P-202 GARAGE LEVEL SANITARY SEWER AND VENT PLAN • • • • • A-412 BUILDING ENVELOPE ELEVATIONS,SECTIONSAND DETAILS • • • • P-203 4TH LEVEL INTERSTITIAL SANITARY SEWER AND VENT PLAN • • • • • A-413 BUILDING ENVELOPE E�EVATIONS,SECTIONS AND DETAILS . . P-204 5TH LEVEL FLOOR SANITARY SEWER AND VENT PLAN • • • • A-414 BUILDING ENVELOPE ELEVATIONS,SECTIONS AND DETAILS • . • • P-205 5TH LEVEL CEILING SANITARY SEWER AND VENT PLAN • • • A-415 BUILDING ENVELOPE ELEVATIONS,SECTIONS AND DETAILS . • . • P-206 6TH LEVEL SANITARY SEWER AND VENT PLAN • • • • A-416 BUILDING ENVELOPE ELEVATIONS,SECTIONS AND DETAILS . . . . P-207 7TH LEVEL SANITARY SEWER AND VENT PLAN • • • • A-417 BUILDING ENVELOPE ELEVATIONS,SECTIONS AND DETAILS . . . . P-208 PLUMBING ROOF ENIARGED PLAN • • • • A-419 BUI�DING ENVELOPE ELEVATIONS,SECTIONS AND DETAILS . • • • P-209 MALL LEVEL DOMESTIC WATER&GAS PLAN • • • • A-421 CONDO TOWER ENLARGED ELEVATIONS AND PLANS • • • • P-210 GARAGE LEVEL DOMESTIC WATER&GAS PLAN I • • • • A-422 ENLARGED PLAN,SECTION&ELEVATIONS • • • P-211 4TH LEVEL INTERSTITIAL DOMESTIC WATER AND GAS PLAN • • A-423 GARAGE SUPPLY&EXHAUST FAN SECTIONS,RETAINING WALL DETAILS • • • • P-212 5TH LEVEL DOMESTIC WATER&GAS PLAN • • • • A-424 CONDO TOWER ROOF ELEVATIONS,SECTIONS AND DETAILS . . . . P-213 6TH LEVEL DOMESTIC WATER&GAS PLAN • • • • P-214 7TH LEVEL DOMESTIC WATE RPLAN • • A-500 BUIIDING ENVELOPE TYPICAL DETAILS • • • P-215 5TH LEVEL GAS PLAN • • A-501 ENLARGED DETAILS • • • • P-216 6TH LEVEL GAS PLAN • • A-502 ENLARGED PLANS,SECTIONS&ELEVATIONS • • • • P-217 7TH LEVEL GAS PLAN • A-503 ENLARGED PLANS,SECTIONS&ELEVATIONS . A-504 ENLARGED PLANS,SECTIONS&ELEVATIONS . P-300 PLUMBWG DIAGRAMS AND DETAILS A-505 ENLARGED PLANS,SECTIONS 8 ELEVATIONS P301 PLUMBING DIAGRAMS AND DETAILS P-302 PLUMBINGDIAGRAMSANDDETAILS A-701 STAIR PLANS AND SECTIONS • • A-702 STAIR PLANS AND SECTIONS • A-703 MISC.STAIRS AND RAMPS PIAND AND SECTIONS • • ELECTRICAL A-704 CAR RAMP TUNNEL • • A-705 ELEVATOR PLANS&SECTIONS • • • • • E-100 ELECTRICAL ONE-LINE DIAGRAM • A-706 ELEVATOR PLANS&SECTIONS E-�01 ELECTRICAL LEGEND,SPECIFICATIONS AND DETAILS . . . . A-707 ELEVATOR PLANS&SECTIONS E-102 DEMAND LOAD CALCULATIONS • • • E-103 PANEL SCHEDULES . . . . A-901 PARTITION TYPES • • • E-104 PANEL SCHEDULES • A-902 PARTITION TYPES • • • E-105 PANEL SCHEDULES E-105 PANELSCHEDULES • • NO. REVISIONS/ISSUANCES DATE A-905 HEAD JAMB AND SILL DETAILS • A-906 WINDOW DETAILS E-201 MALL LEVEL POWER AND SYSTEMS PLAN • • • • • A-907 WINDOW DETAILS E-202 GARAGE LEVEL POWER AND SYSTEMS PLAN-WEST • • • E-203 GARAGE LEVEL POWER AND SYSTEMS PLAN-EAST • . . • A-910 DOOR SCHEDULE • • • E-204 1st FLOOR POWER AND SYSTEMS PLAN • • • A-911 DOOR TYPES,FRAMES AND DETAILS • • E-205 2nd FLOOR POWER AND SYSTEMS PLAN • • • A-912 W INDOW SCHEDULE,TYPES,FRAMES AND DETAILS . . E-206 PARTIAL 3rd,4th&8th FLOOR PQWER AND SYSTEMS PLANS • . . E-207 5th FLOOR POWER AND SYSTEMS PLAN • • • E-208 6th FLOOR POWER AND SYSTEMS PLAN • • • TOTALS E-209 7th FLOOR POWER AND SYSTEMS PLAN • • • E-210 8th FLOOR POWER AND SYSTEMS PLAN • • E-2�1 ROOF POWER AND SYSTEMS PLAN • • • INTERIORS E-301 MALL�EVEL LIGHTING PLAN • • • • I-101 UNIT 100 PLAN,FLOOR 01 FLOOR PLANS AND SCHEDULES . . . . . E302 GARAGE LEVEL LIGHTING PLAN-WEST • • • • • I-102 UN�T 200 PLAN,FLOOR 02 FLOOR PLANS AND SCHEDULES • • . • • E303 GARAGE LEVEL LIGHTING PLAN-EAST • • • • • I-103 UNIT 300 PLAN,FLOOR 03 FLOOR PLANS AND SCHEDULES . . . . . E-304 1 st FLOOR LIGHTING PLAN • • • I-104 UNIT 400 PLAN,FLOOR 04 FLOOR PLANS AND SCHEDULES . • . • . E305 2nd FLQOR LIGHTING PLAN • • • I-105 UNIT 51 PLAN,FLOOR 05 FLOOR PLANS AND SCHEDULES . . • . . E306 PARTIAL 3rd&4th FLOOR UGHTING PLANS . . . I-106 UNIT 52 PLAN,FLOOR 05 FLOOR PIANS AND SCHEDULES • . . . . E-307 5th FLOOR LIGHTING PLAN . • . • 4 REISSUE FOR PERMIT 9 03/12/08 I-107 UNIT 53 PLAN,FLOOR 05 FLOOR PLANS AND SCHEDULES . • . . • E-308 6th FLOOR LIGHTING PLAN • • • I-108 UNIT 54 PLAN,FLOOR OS FLOOR PLANS AND SCHEDULES . . . . E-309 7th FLOOR LIGHTING PLAN • • • 3 ISSUE FOR PERMIT/BID/100� CDs 01/18/08 I-109 UNIT 55 PLAN,FLOOR 05 FLOOR PLANS AND SCHEDULES • • • • • I-110 UNIT 56 PLAN,FLOOR 05 FLOOR PLANS AND SCHEDULES . . . . . Z 100% DES. DEVELOPMENT/GMP 10/01/07 I-111 UNIT 57 PLAN,FLOOR 05 FLOOR PLANS AND SCHEDULES • • • • • I-112 UNIT 57,FLOOR 05 FLOOR PLANS . . . . . FIRE PROTECTION 1 50q DESIGN DEVELOPMENT 08 16 07 I-113 UNIT 61 PLAN,FLOOR 06 FLOOR PtANS AND SCHEDULES • • . • • I-114 UNIT 61 FLOOR 06 AND LOFT FLdOR PLANS • • • • • FP-101 FIRE PROTECTION MALL LEVEL PLAN • • • • . N0. REVISIONS/ISSUANCES DATE I-115 UNIT 62 FLOOR PLANS AND SCHEDULES • • • • • FP-102 FIRE PROTECTION GARAGE LEVEL PLAN • • • • I-116 UNIT 62 LOFT FLOOR PLANS • • • • • FP-103 FIRE PROTECTION 1ST LEVEL PLAN • • • • . SHEEf TITLE I-117 UNIT 63 FLOOR PLANS AND SCHEDULES • • . . • FP-104 FIRE PROTECTION 2ND&3RD FLOOR PLAN • • • • • I-118 UNfT 63 LOFT FLOOR PLANS • • • • • FP-105 INTERSTITIAL SPACE/FOURTH LEVEL&FIFTH LEVEL • • • • • D RA W I N G I-119 UNIT 64 FLOOR PLANS AND SCHEDULES . . . FP-106 SIXTH LEVEL 8 SEVENTH LEVEL • • • • • I-120 UNIT 64 LOFT FLOOR PLANS • • • • • I-121 UNTI 65 FLOOR PLANS AND SCHEDULES , , � � � FP-107 MISCELLANEOUS&DETAILS • • • • • I-122 UNIT65LOFTPLANS . . . . . INDEX I-123 UNIT 66 FLOdR PLANS AND SCHEDULES • • • • I-124 UNIT 66 LOFT FLOOR PLANS • • • • • I-125 MALL FLOOR PLANS AND SCHEDULES • . • • FIRE ALARM I-126 GARAGE FLOOR PLANS AND SCHEDULES • • • FA-101 FIRE ALARM MALL LEVEI PLAN • • • • • FA-102 FIRE ALARM GARAGE LEVEL PLAN • • • • . CARL GERGITS PROJECT MANAGER I-201 5TH FLOOR TYPICAL ELEVATIONS • • • • FA-103 FIRE ALARM FIRST LEVEL PLAN • • • • • I-202A 6TH FLOOR TYPICAL E�EVATIONS • • • • FA-104 FIRE ALARM 2ND&3RD LEVEL PLAN • • • • • I-202B 6TN F�OOR MEZZANINE ELEVATIONS • • FA-105 INTERSTITIAL SPACE/FOURTH LEVEL&FIFTH LEVEL • • • • . EDWARD CURLEY ARCHITECT/ENGINEER I-203 COMMON AREA ELEVATIONS • • • FA-106 FIRE ALARM 6TH&7TH�EVEL PLAN • • • • • I-206 LOBBY ELEVATIONS FA-107 FIRE ALARM MISCELLANEOUS • • • • 272.�0 PROJECT NUMBER I-300 DETAILS • • • • 1301 DETAILS • • • • SCALE 1302 FIREPLACE ENLARGED PLANS AND ELEVATIONS • • • • TELECOM/SECURITY I-303 RECEPTION DESK PLANS AND ELEVATIONS I • • , H.CHO DRAWN BY CHECKED BY SHEEf NUMBER � SEAL C�2007 A. Epstein and Sons International, Inc. All rights reserved.