Loading...
HomeMy WebLinkAboutA11-0030TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES WW ' OM ' BTU[ III OWNER APPLICANT CONTRACTOR Desciption Valuation Job Address: 531 LIONSHEAD MALL VAIL Location.....: LIONSHEAD ARCADE UNIT 206 Parcel No...: 210106314006 Project No MARIO CONCHA & ASSOCIATES LL 07/14/2011 PO BOX 1768 VAIL CO 81658 ACME ALARM COMPANY P.O. BOX 883 RIFLE CO 81650 License: 154 -S ACME ALARM COMPANY CLINT BARTELS PO BOX 883 RIFLE CO 81650 License: 0000003233 INTERIOR REMODEL $1,200.00 Permit #: All -0030 Status ...: ISSUED Applied..: 07/14/2011 Issued . .: 07/29/2011 Expires . .: 01/25/2012 07/14/2011 Phone: 970 - 625 -3398 07/29/2011 Phone: 970 - 625 -3398 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Electrical --------- > $0.00 Total Calculated Fees - -> $333.00 DRB Fee --------- > $0.00 Additional Fees ---------- > ($117.00) Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $216.00 Will Call --------- > $0.00 Payments ------------------ > $216.00 TOTAL FEES--> $333 .00 BALANCE DUE--- - - - - -> $0.00 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Approvals: Item: 05600 FIRE DEPARTMENT 07/14/2011 mvaughan Action: AP CONDITIONS OF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALT. BE MADE TW EN'rV401'R HOURS IN A CE BY TELEPH AT 970 -479- FRO "B Ba.A 5 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL,, COLORADO Statement Statement Number: R110000893 Amount: $216.00 07/29/201102:11 PM Payment Method: Check Init: LC Notation: 412042 / ACME ALARM ----------------------------------------------------------------------------- Permit No: All -0030 Type: ALARM PERMIT Parcel No: 2101 - 063 - 1400 -6 Site Address: 531 LIONSHEAD MALL VAIL Location: LIONSHEAD ARCADE UNIT 206 Total Fees: $216.00 This Payment: $216.00 Total ALL Pmts: $216.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts PF 00100003112300 PLAN CHECK FEES 216.00 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 -2128 Fax: 970 - 479 -2452 Web: www.vailgov.com development Review Coordinator FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Pr Address: I (Number) (Street) (Suite #) Building /Complex Name: Lbw','�ErS Contractor Information: Company: krh t' 0 Y Company Address: P.O. Q 0 X 8 City: ( M C State: C 0 Zip: 'K L-SO Contact Name: -G cn� Pa� Contact Phone: Q U-[o 5 ` S S 3 S E -Mail C� ac e-lectl '- nom, C Ur L Town of Vail Contractor Registration No.: X . Contractor Signature (required) Property Information Parcel #: (For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or visit www.eaglecounty.us/patie) Tenant Name: Owner Name: Complete Valuation for Fire Alarm Permit Fire Alarm $: A J Office Use: Project #: PkS IL V a I t i ) Building Permit #: _l] i - i as Alarm Permit #: A I , - 00 3o Lot #: Block # Subdivision: Detailed Description of Work: _ U"J : T .moo C` ern �1�- -e � t,�; S c_ %�� ..►c9 p-r` �j �.S PS (use additional sheet if necessary) Does a Fire Alarm Exist? Yes M No ( ) Does a Sprinkler System Exist? Yes (4 No ( ) Work Class: New ( ) Addition ( ) Remodel ()id Repair Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family) Commercial ( ) Restaurant ( ) Other ( ) Date Received: JUL 12 2011 TOWN OF VAIL 29- May -09 Acme Alarm Company PO Box 883 Rifle, CO 81650 Phone 970 -625 -3398 Fax 970 -625 -0870 "We Set The Standards for Security!" coLoRROO 6 Q �� SILENT , KNIGHT N NFPA ® T Lionshead Arcade Unit 206 6/20/11 Permit Scope and Sequence Overview: Acme Alarm Company will install 3 smoke detectors with sounder bases in unit while under construction. Component Configuration: While unit 206 is under construction there will need to be smoke detection added to the bedrooms and tied into the existing fire alarm system. The existing fire alarm system is a Gamewell 650 panel. The new devices will consist of XP -95 Smokes mounted on Sounder Bases for local and general alarm. The devices will be mounted on the walls as this building is a prefab concrete ceiling. Backup System: Power to the fire alarm system is backed up two fold. Primary AC power to the system is backed by generator. The secondary backup is provided by one set of 33AH batteries. The voice evacuation system shall be backed up in each of the distributed panels by twelve amp hour batteries. Notes: 1. All connections will be terminated on terminal strips and or switchable crossbar connections to adequately be able to service and troubleshoot the system. 2. Dedicated 120 AC power to be provided to fire control panel and auxiliary power supplies including locking breaker at breaker panel by job site electrician. (20 amp minimum) 3. Two phone lines are to be provided to the panel and will precede any switch equipment. 4. All current draws shall be field verified. Time Frame: 2 days Gamewell - FIRE CONTROL INSTRUMENTS by Honeywell XP95 -P Description The Gamewell -FCI XP95 -P analog addressable photoelec- tric sensor operates with the Gamewell -FCI analog addres- sable Fire Alarm Control Panels (FACPs). The photoelectric sensor digitally transmits its address and the chamber's analog values to the FACP for analysis. The photoelectric sensor is distinguished by the clear status LED, which flashes red briefly when the device is polled and turns on continuously when the device is in alarm. Operation The XP95 -P photoelectric sensor constantly monitors its sensing chamber and its internal electronics. The results are then reported along with the unit's address through the integral communications electronics located in the sensor head. The XP95 photoelectric sensor utilizes a patented smoke chamber and infrared smoke sensing design. The infrared emitter generates a burst of light every second, or in response to direct interrogation. In clean air, the photo diode receives no light from the emitter because of the arrangement of the chamber. When smoke enters the chamber, it scatters light from the emitter onto the photo diode receptor in proportion to smoke char- acteristics and density. As the smoke content in the cham- ber increases, the signal from the photo diode receptor increases. This information is processed and conditioned by an on- board, advanced - technology ASIC and digitally transmitted to the FACP. Trouble and Alarm conditions of the XP95 sensors are actually determined at the control panel. The status infor- mation of each sensor is analyzed for off - normal conditions by the FACP. If the sensor reports a condition that matches its programmed trouble signature, the FACP will detect that the sensor is in trouble and will follow its programmed response sequence. If the status reported matches the alarm signature, the FACP will follow the programmed alarm response for the specific device in alarm. When a sensor is in alarm, the integral LED in the sensor's housing will light continuously. Photoelectric Smoke Sensor lip•- % 3 C -• CV t � ' U XP95 -P Features • Compatible with the Gamewell -FCI 600 Series analog addressable control panels • Fits 4.0" (10.16 cm) or 6.0" (15.24 cm) ultra -low- profile E -Z fit bases • Audible alarm sounder base • Four -wire relay base • Address is stored in the sensor base • Address is set by XPert addressing card • Two -color status LED • Infrared smoke sensing design • Continuous communications • Optional remote LED An ISO 9000 -2000 Company SIGNALING uL FM MEA LISTED Appr.VEd 51195 APPROVED 149 -99 -E GAMEWELL -FCI 12 Clintonville Road, Northford, CT 06472 -1610 USA • Tel: (203) 484 -7161 • Fax: (203) 484 -7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell -FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell- fci.com CS -2054 Rev. a1 page 1 of 2 Operation (Continued) The XP95 -P photoelectric device is connected to a two - wire SLC carrying both data and a 17 to 28 VDC supply voltage, and is insensitive to loop connection polarity. A remote LED indicator may be connected. The device is compatible with point -or group - addressable relay and sounderbases. Engineer's Specifications The contractor shall furnish and install, where indicated on the plans, photoelectric smoke sensors with one of the several addressable mounting base options available. The combination sensor head and twist -lock mounting base shall be UL Listed and UL Listed as compatible with the Gamewell -FCI 600 Series analog addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The photo- electric smoke sensor shall be the Gamewell -FCI model XP95 -P. Specifications Standby Current: 340 pA Alarm LED Current: 0.00434 A Remote Alarm addressable (55000 -650) Output: 0.004 A @ 5 VDC Temperature Range: 32 °F to 140 °F (0° C to 60° C) Relative Humidity: (non- condensing) 0% to 95% Recommended (four -wire) with XPert addressing card Spacing: Meets the 30 ft. (9.1 m) spacing guidelines in NFPA 72 Chapter 2. However, this spacing is based on 71112 ideal conditions and is to be used 30203 as a layout guide only. Appropriate installation - specific engineering is required. Ordering Information Model Description XP95 -P Photoelectric sensor, analog addressable (55000 -650) XP95 -134 4.0" (10.16 cm) mounting base with XPert addressing card (45681 -2101) XP95 -136R4 6.0" (15.24 cm) relay base (four -wire) with XPert addressing card XP95- B6SNDR 6.0" (15.24 cm) mounting base with XPert addressing card and audible alarm sounder in the base 71112 Additional blank XPert addressing cards 30203 Remote LED (24 V) on single gang plate GAMEWELL -FCI 12 Clintonville Road, Northford, CT 06472 -1610 USA • Tel: (203) 484 -7161 • Fax: (203) 484 -7118 CS -2054 Rev. at page 2 of 2 www.gamewell - fci.com Gamewell FIRE CONTROL INSTRUMENTS by Honeywell 0200SO Description The B200SR Series sounder bases set a new stan- dard for performance, installation, and aesthetics. The B200SR is designed for new and existing dwell- ing unit applications. It offers maximum flexibility in installation, configuration, and operation to meet or exceed the UL °268 and UL° 464 requirements. The B200SR is fully compatible with the existing B501 BH- Series sounder base installations. By removing a jumper, the device enables users to select one of two B501- supported tones (ANSI Temporal 3 or Continuous). With its attractive aesthetics, the B200SR is ideal for applications where appearance is critical. For exam- ple, the sounder base employs a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface -mount boxes. In addition, the mounting plate enables pre- wiring of all connec- tions to simplify the installation. The housing is installed with the mounting plate and is locked in position with two retaining screws. The retaining screws are covered by the installed sensor head for added tamper resistance. Specifications Physical Specifications Base Diameter: 6.875" (17.46 cm) Base Height: 2.0" (5.08 cm) less sensor Shipping Weight: 0.50 lb. (227 gm) Operating Temperature Range: 32° to 120° F (0° to 49° C) Operating Humidity 10% to 93% relative humidity Range: (non- condensing) Electrical Specifications External Supply Voltage 16 to 33 VDC (VFWR) External Supply Standby Current: 500 pA maximum Alarm Current: 35 mA maximum SLC Operating Voltage: 15 to 32 VDC SLC Standby Current: 300 pA maximum Sound Output: Greater than 85 dBA mini- mum — measured in a UL reverberant room at 10 ft. 24 Volts (in continuous tone) UL is a registered trademark of Underwnters Laboratories Inc Intelligent Sensor Sounder Base B200SR Features • Tone selection via an onboard jumper • UL° 268 and UL° 464 compliant • Pre -wire mounting plate fits various junction box sizes • Fully compatible with the existing B501 BH- Series sounder base installations • Mechanical locking feature prevents the removal of the attached sensor head Ordering Information Part Number Description B200SR Intelligent Sensor Sounder Base An ISO 9000 -2000 Company SIGNALING U� FM I I LISTED APPROVED S1911 S1911 3035027 7135 -1653 :213(B200SRA) GAMEWELL -FCI 12 Clintonville Road, Northford, CT 06472 -1610 USA • TeL (203) 484 -7161 • Fax: (203) 484 -7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell -FCI for their use. 02009 by Honeywell International Inc. All rights reserved. www.gamewell4ci.com 9021 -60553 Rev. A page 1 of 1