BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address:
292 West Meadow Drive
(Number) (Street) (Suite #)
Building/Complex Name: Vail Public Library
Contractor Information
Business Name: Town of Vail
Business Address: 1309 Elkhorn Drive
City Vail State: CO Zip: 81657
Contact Name: Todd Oppenheimer
Contact Phone: 479-2161
Contact E-Mail: toppenheimer@vailgov.com
Contractor Registration Number: GC will provide after contract
X� !t� I�.� �.- _
Owner/Owner's Repr sentative Signature (Required)
Project Information
Owner Name: I own ot vail �O( - D(aN- �'7-D�S
Parcel #: Vail Lionshead #2, Block 1, Library
(For Parcel #, contact Eagle County Assessors OHice at (970-328-8640 or visit
www.eag lecou nt y. us/pa tie )
Project #: PR � I I "
DRB #:
BuildingPermit#: iC7�����`.�
Lot #: Block # Subdivision:
Work Class: New ( ) Addition ( ) Aiteration ( �/ )
Type of Building:
Single-Family ( ) Duplex ( ) Multi-Family ( )
Commercial (�/) Other ( )
Work Type
Interior (✓ ) Exterior ( ) Both ( )
Valuation of
Work
Work Included Plans Included
Electrical (�/)Yes ( )No ( )Yes ( )No
Mechanical ( )Yes ( )No ( )Yes ( )No
Plumbing ( )Yes ( )No ( )Yes ( )No
Bui�ding (,�)Yes ( )fvo ( )Yes ( )No
Value of all work being performed: $
(value based on IBC Section 109.3 & IRC Section 108.3�
Electrical Square Footage
Detailed Scope and Location of Work: Replacement of book stacks, cabinets and counters with associated electrical and
communication wiring; Replacement of light fixtures; Replacement of carpet; Moving existing walls.
(use additional sheet if necessary)
For Office Use Only:
Fee Paid: I��c. W A►U� ExC.�Pr Ec.�ccQ►ea�
Received From:
Cash Check #
CC: Visa / MC Last 4 CC # exp date:
Auth #
Date Received:
oc��ad�
JUL 13 1U11
TOWN OF VAIL
01-Jan-I 1
Indoor Environmental Services, Inc
Dba: Q Consulting, Inc.
Town Of Vail
Site 6 — Library
292 W Meadow Dr, Vail, Colorado
Asbestos Inspection Report — Page 1 of 2
March 1, 2011
John Gallegos
Facilities Manager
Town of Vail
On February 26, 2011, Quentin Danziger conducted an asbestos inspection of the suspect
materials throughout the building. Asbestos was NOT found, as described below.
Homogenous Description Number of % Asbestos Square Type/Friable?
Area Sam les Feet
O1 Texture 3 Non Detect
02 Sheetrock/JC 3 Non Detect
03 Floor Tile 3 Non Detect
Under Carpet
in Copy Room
with 2 Mastics
04 Office Ceilin 3 Non Detect
OS Bathroom 3 Non Detect
Ceilin
BACKGROUND:
The Town of Vail requested an asbestos inspection of this building. Roofing materials
were not seen, but inspection was limited due to snow. If suspect roofing material
such as tar paper is found during remodel, contact Quentin at 970-390-0087.
This inspection includes only suspect materials that are visible to the inspector. If other
suspect materials become visible during demolition, they must be sampled before they
are disturbed. Examples of suspect materials include but are not limited to: linoleum,
floor tile, ceiling tile, mastic, sheetrock, joint compound, roofing materials, etc. There are
over 3000 known asbestos containing materials.
SAMPLING PLAN:
Colorado State Requirements - For each homogenous area of less than 1000 square
feet, a minimum of three samples must be collected in random areas. For each
Indoor Environmental Services, Inc
Dba: Q Consulting, Inc.
Town Of Vail
Site 6 — Library
292 W Meadow Dr, Vail, Colorado
Asbestos Inspection Report — Page 2 of 2
homogenous area of 1000 — 5000 square feet, a minimum of five samples must be
collected in random areas. Areas of 5001 square feet or greater require a minimum of 7
samples. These laws are defined by the EPA (AHERA) and Colorado State Regulation 8.
Determination of homogenous sampling areas — Homogenous Areas are determined by
type of suspect material, texture, color and location.
Determination of random sampling areas — The samples were collected in a random
manner.
Thank you for using Q Consulting, Inc. We are proud to be your local indoor air quality
consultants. We look forward to working with you in the future.
Quentin Danziger, BS, CIE, ABI — Colorado Asbestos Inspector Certification # 12781
Indoor Environmental Services, Inc.
Dba Q Consulting, Inc.
970-390-0087
QConsultingInc@yahoo.com
EMSL Analytical, Inc.
— 7330 S. Alton Way E3tiildincg 12 Suite A, Centeniiial, cC} 80112
Pt,U�,e.: �., s� t��-� s���=�; � � �:4��i� ��
A"" Quentin Danziger
Q Consulting, Inc.
PO Box 997
Vail, CO 81658
Fax Phone: (970) 390-0087
Project: TOV - Vail Library
customer ID:
customer Po:
Received:
EMSL Order:
EMSL Proj:
Analysis Date:
I NES78
03/01/11 9:00 AM
221100660
Town of Vail
3/1/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance °/, Fibrous % Non-Fibrous % Type
01-01 Te�Qure White/Yellow 100% Non-fibrous (other) None Detected
227100660-0001 Non-Fi brous
Heterogeneous
01-02 Te�Qure
221f00660-0002
01-03 Te�Qure
227f00660-0003
02-01-Texture
221100660-0004
02-01-Joint
Compound
221f00660-0004A
SheeVock/J C
Sheetrock/JC
White/Yellow
Non-Fibrous
Heterogeneous
White/Yellow
Non-Fibrous
Heterogeneous
White/Yellow
Non-Fibrous
Heterogeneous
White
Non-Fibrous
Homogeneous
100% Non-fibrous (other)
100% Non-fibrous (other)
100% Non-fibrous (other)
100% Non-fibrous (other)
None Detected
None Detected
None Detected
None Detected
02-01-Drywall Sheetrock/JC Brown/White 10% Cellulose 85% Non-fibrous (other) None Detected
zziioosso-0004s Fibrous 5% Glass
Heterogeneous
02-02-Texture SheeVock/JC Brown/White 100% Non-fibrous (other) None Detected
221100660-0005 Non-Fi brous
Heterogeneous
Irrtial report from03�01/2011 17:12:15
,4nayst(s)
Erin Orthun (9) Erin Orthun, Laboratory Manager
Molly Walker (18) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples repoAed and may not be reproduced, except in full, without written approval by EMSL. E
no responsibility for sample collection actiNties or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This repoA must not be use
client lo claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federel govemment. Non-fiable organically bound matenals present a problam i
theretore EMSL recommends graNmetnc reduction prior to analysis. Samples recaieed in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical, Ina Cenlennial, CO NVLAP Lab Coda 200828-0
TestReport PLM-7.23.0 Prin�ed:3/1/20115:25:15PM
0
EMSL Analytical, Inc.
— 7330 S. Alton Way Building 12 Suite A. Centennial,±'C't £3Q11?,
Pht7nE: (3u'� `iG_,';00 t� 03r '.1-i.;C�i� � � � � � ,�
A�'� Quentin Danziger
Q Consulting, Inc.
PO Box 997
Vail, CO 81658
Fax Phone: (970) 390-0087
Project: TOV - Vail Library
customer ID:
Customer PO:
Recei�ed:
EMSL Order:
EMSL Proj:
Analysis Date
INES78
03/01/11 9:00 AM
221100660
Town of Vail
3/1/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance °/, Fibrous % Non-Fibrous % Type
02-02-Joint SheeVock/JC White 100% Non-fibrous (other) None Detected
Compound Non-Fibrous
22 U 00660-OOOSA
Homogeneous
02-02-Drywall Sheetrock/JC Brown/White 10°/a Cellulose 85% Non-fibrous (other) None Detected
2ziioosso-000se Fibrous 5% Glass
Heterogeneous
02-03-Texture Sheetrock/JC TaMNhite 100% Non-fibrous (other) None Detected
zz�ioosso-000s Non-Fibrous
Heterogeneous
02-03-Joint Sheetrock/JC White 100% Non-fibrous (other) None Detected
Compound Non-Fibrous
221f00660-0006A
Homogeneous
02-03-Drywall Sheetrock/JC Brown/White 10% Cellulose 85% Non-fibrous (other) None Detected
221100660-0006B Fibrous 5% Glass
Heterogeneous
03-01-Tan Mas6c Floor Tile Under Tan 100°/a Non-fibrous (other) None Detected
221f00660-0007 Carpet-Copy Non-Fibrous
Room Homogeneous
Irrtial report from Oy01/2011 17:12:15
Ariayst(s)
Erin Orthun (9) Erin Orthun, Laboratory Manager
Molly Walker (18) or other approued signatory
EMSL maintains liability limited to cost of analysis. This rapoA relales only to the samples raporled and may not be reproduced, except in full, without wntten approval by EMSL. E
no responsibility for sample collection actiHties or analytical method limitations. Interpretation and use of test results are the responsibility oi tha client. This raport must not be use
cliant to claim product cartification, approval, or endorsement by NVLAP, NIST or any aqency of the federal go�,emment. Non-fnable organically bound matenals present a problem i
therefore EMSL recommends gretimetric raduction prior to analysis. Samples raceieed in good condition unless otherwise noted.
Samples analyzed Dy EMSL Analytical, Inc. Centennial, CO NVLAP Lab Coda 200828-0
Test Report PLM-7.23.0 Printed: 3/1/2011 5:25:15 PM
2
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial. CO 80112
F I�,�,T�::: j u a� .{�i)..5'On f.�:ax�. (3031 741-1400 Ei7kiil: �� i...��� ,!� ,ritsLc_",in
A�TM'� Quentin Danziger
Q Consulting, Inc.
PO Box 997
Vail, CO 81658
Fax
Project: TOV - Vail Library
Phone: (970) 390-0087
customer ID:
customer Po:
Receiued:
EMSL Order:
EMSL Proj:
Analysis Date:
INES78
03/01/11 9:00 AM
221100660
Town of Vail
3/1 /2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance °/, Fibrous % Non-Fibrous % Type
03-01-Floor Tile Floor Tile Under White 100% Non-fibrous (other) None Detected
221f00660-0007A Carpet-Copy Non-Fibrous
Room Homogeneous
03-01-Black Mastic Floor Tile Under Black
zz��oosso-000�e Carpet- Copy Non-Fibrous
Room Homogeneous
03-02-Tan Mastic Floor Tile Under Tan
221100660-0008 Carpet - Copy Non-Fibrous
Room Homogeneous
03-02-Floor Tile Floor Tile Under White
221100660-0008A Carpet-Copy Non-Fibrous
Room Homogeneous
03-02-Black Mastic Floor Tile Under Black
221100660-0008B Carpet - Copy Non-Fibrous
Room Homogeneous
03-03-Tan Mastic
221100660-0009
03-03-Floor Tile
221100660-0009A
Floor Tile Under Tan
Carpet - Copy Non-Fibrous
Room Homogeneous
Floor Tile Under White
Carpet-Copy Non-Fibrous
Room Homogeneous
Iritial report from03�01/2011 17:12:15
,4rraryst(s)
Erin Orthun (9)
Molly Walker (18)
100% Non-fibrous (other)
100% Non-fibrous (other)
100% Non-fibrous (other)
100% Non-fibrous (other)
100% Non-fibrous (other)
100% Non-fibrous (other)
Erin Orthun, Laboratory Manager
or other approued signatory
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
EMSL mainlains liability limited to cost ot analysis. This repoA relates only to the samples reported and may not be reproduced, except in full, without wntten approval by EMSL. E
no responsibility tor sample collection actiHties or analytical method limitations. Interprelation and use of test results ere the responsibility of the client. This report must not be use
client to claim product ceAification, approval, or andorsement by NVLAP, NIST or any agency of the Tederal go�emment. Non-fnable organically bound matenals present a problem i
therefore EMSL recommends graHmetric reduction pnor to analysis. Samples recei�ed in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical, Inc. Centennial, CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Prin�d: 3/1/2011 5:25:15 PM
3
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, CentenniaL CO 80112
PhOrY�'.: (;03)7410-5700 Fdx iS0;1�'4�-1.1UC l!ri4�iL f'a•i?veritfL ,� �
A�'� Quentin Danziger
Q Consulting, Inc.
PO Box 997
Vail, CO 81658
Fax
Project: TOV - Vail Library
Phone: (970) 390-0087
customer ID:
customer Po:
Recei�ed:
EMSL Order:
EMSL Proj:
Analysis Date:
INES78
03/01/11 9:00 AM
221100660
Town of Vail
3/1/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance °/, Fibrous % Non-Fibrous % Type
03-03-Black Mastic Floor Tile Under Black 100°/a Non-fibrous (other) None Detected
221f00660-0009B Carpet-Copy Non-Fibrous
Room Homogeneous
04-01 Office Ceiling White 80% Min. Wool 10% Non-fibrous (other) None Detected
221100660-0010 Fibrous 10% Perlite
Heterogeneous
04-02 Office Ceiling White 80% Min. Wool 10% Non-fibrous (other) None Detected
221f00660-0011 Fibrous 10% Perlite
Heterogeneous
04-03 Office Ceiling White 80% Min. Wool 10% Non-fibrous (other) None Detected
zz�ioosso-oo�2 Fibrous 10% Perlite
Homogeneous
05-01 Bathroom Ceiling Brown/White 40% Cellulose 10% Non-fibrous (other) None Detected
221100660-0013 Fibrous 40% Min. Wool 10% Perlite
Heterogeneous
05-02 Bathroom Ceiling BrowrUWhite 40% Cellulose 10% Non-fibrous (other) None Detected
221100660-0014 Fibrous 40% Min. Wool 10% Perlite
Heterogeneous
05-03 Bathroom Ceiling TaNWhite 40% Cellulose 10% Non-fibrous (other) None Detected
zziioosso-oois Fibrous 40% Min. Wool 10% Perlite
Heterogeneous
Iritial report from 03/01/2011 17:12:15
Analyst(s)
Erin Orthun (9) Erin Orthun, Laboratory Manager
Molly Walker (18) or other approred signatory
�:MSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without wntten approval by EMSL. E
o responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be use
lient to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federel go�emment. Non-fnable organically bound matenals present a problem i
ierefore EMSL recommends graWmetnc reduction pnor to analysis. Samples recei�ed in good condition unless otherwise noted.
�amples analyzed by EMSL Analytical, Ina Centennial, CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Prin4ed: 3/1/2011 5:25:15 PM THIS IS THE LAST PAGE OF THE REPORT. 4