Loading...
HomeMy WebLinkAboutB11-0220NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 0', MAorVk . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: 1311 -0220 Job Address: 1815 GORE CREEK DR VAIL Location......: BOTH HALVES Parcel No....: 210312306017 OWNER WELLES, DAVID EDWIN 1815 W GORE CREEK DRIVE A VAIL CO 81657 APPLICANT PARADISE DEMOLITION AKA BONAFIDE DEMOLITION P.O. BOX 2343 VAIL CO 81658 License: 655 -S CONTRACTOR PARADISE DEMOLITION AKA BONAFIDE DEMOLITION P.O. BOX 2343 VAIL CO 81658 License: 655 -S 07/19/2011 07/19/2011 Phone: 970-904-0173 07/19/2011 Phone: 970-904-0173 Description: REPLACING WOOD SHAKE ROOF WITH ASPHALT ARCHITECTURAL SHINGLE ON BOTH HALVES OF DUPLEX. Project #: Applied.....: Issued... PRJ 11 -0090 07/19/2011 07/26/2011 Occupancy: Type Construction: Valuation: $10,000.00 ...... ............................... ............ �..,............... «..,....... FEE SUMMARY .,.......,.............,,.>.,................. ..,....,...,..,.....,.......... Building Permit ------ - - - - -> $181.25 Bldg Plan Check ----- - - - - -> $117.81 Use Tax Fee------------------ - - - - -> $0.00 Electrical Permit ---- - - - - -> $0.00 Elec Plan Check ------ - - - - -> $0.00 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees--------------- - - - - -> ($5.00) Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $0.00 Will Call- - - -- -- - - - - -- -> $5.00 TOTAL PERMIT FEES --- ---------- > $299.06 Payments -- ---------------------------- > $299.06 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:0 PM. 0- ,tort Signa re Owner or Contractor Date 6 Print Name combination permit_012811 1• TOWN 104F CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0220 Owner: WELLES, DAVID EDWIN BOTH HALVES combination permit-012811 Address: 1815 GORE CREEK DR VAIL Location: OVAk' TOWN OF REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0220 Owner: WELLES, DAVID EDWIN BOTH HALVES Address: 1815 GORE CREEK DR VAIL Location: Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110000848 Amount: $186.25 07/26/201111:16 AM Payment Method: Check Init: LC Notation: #2143 / DAVID E. WELLES, PARADISE DEMOLITION ----------------------------------------------------------------------------- Permit No: Bll -0220 Type: COMBINATION BLDG PERMIT Parcel No: 2103 - 123 - 0601 -7 Site Address: 1815 GORE CREEK DR VAIL Location: BOTH HALVES Total Fees: $304.06 This Payment: $186.25 Total ALL Pmts: $304.06 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 BUILDING PERMIT FEES 181.25 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADOCopy Reprinted on 01 -07 -2013 at 16:50:54 01/07/2013 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R110000806 Amount: $117.81 07/19/201102:20 PM Payment Method: Check Init: DR Notation: CK# 2134 DAVID WELLES ----------------------------------------------------------------------------- Permit No: Bll -0220 Type: COMBINATION BLDG PERMIT Parcel No: 2103 - 123 - 0601 -7 Site Address: 1815 GORE CREEK DR VAIL Location: BOTH HALVES Total Fees: $304.06 This Payment: $117.81 Total ALL Pmts: $304.06 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 117.81 I t Department, of Community Development: 75 South Frontage Road y ,.k Vail, Colorado 8'i65Y 4 r Tel: 970 - 479 - 2128.• } � Web: www.vailgov.com Development Review Coordinator • BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: IS 15— ids G0QLL GZF-LK nfZ (Number) (Street) / (Suite #) / Building /Complex Name: Q A Contractor Information Business Name: f ILCCI a beelo r `0c, Business Address: Po LC a 3 y 5 City 4, t State: O Zip: 6 S Contact Name: JGtSaI, Contact Phone: 970-33 1 I y S Contact E -Mail: PG�G�&Ae cteMdAi -110 i�o +ma;k , Coo, Contractor Registration Number: Project #: pp DRB #: MS l [ DD80 Building Permit #: I) I I— n a;a C-) Lot #: Block # Subdivision: Work Class: New ( ) Addition ( ) Alteration ( � ) Type of Building: Single - Family ( ) Duplex (✓f Multi - Family ( ) Commercial( ) Other( ) Work Type: Electrical X 1 zzz_11, Mechanical Owner /Owner's Representative Signature (Required) Plumbing Interior ( Work Included )Yes (x)No )Yes (()No )Yes (�, )No Exterior (✓f Both ( ) Valuation of Plans Included Work )Yes ( )No )Yes ( )No )Yes ( )No Project Informatio r Building (Yes ( )No ( )Yes ( )No U Owner Name: bOw r (� I W 2 S Value of all work being performed: $ / (�} U Vo Parcel #:,14)9 - 1.73'06 ` 0 /9' f-) 10 3- /.13 - 06 017 (value based on IBC Section 109.3 & IRC Section 708.3) (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us /patie) Electrical Square Footage Detailed Scope and Location of Work: 1�Q - 5 n��2 ���� U5t,!c. 61t GSDhai 71(Chl�eJ,C& �c- 1v►0u)XJr C�__nAa _St qt r-_ (use additional sheet if necessary) For Office Use Only: Fee Paid: Received From:[M)� W P Cash Check # L( CC: Visa / MC Last 4 CC # exp date: Auth # Date Received: �} -- AX 14 20), 01- Jan -II I it .2Y D f � l t 12 el - 33,8' J D �r i IT l?' ell JQ I - I ;z /96 Wos+ Goce_ C necr bev 54,v �evu,trot, CI ,p -7//2 ; p; +r-4 oP AoW JUL 14 2011 TOWN OF VAIL Page 14 SNOW GUARD 809 TECHNICAL INFORMATION Snow Guard Guidelines DETERMINING THE PROPER AMOUNT OF TORQUE FOR SET SCREWS will vary depending on the type and gauge of metal roofing. The recommended method for determining proper torque is to install one unit first, with blade on the uphill side. After tightening the set screws, loosen and remove the unit, inspecting the indentations created in the seam to see that proper compression was obtained. Remember, the screw closest to the blade is the real workhorse as it derives its strength from the blade, and if extra torque is needed, apply it to this screw. WHEN MECHANICALLY FASTENING SNOW GUARDS, use sealant or neoprene washers to ensure watertight seals. It is imperative to secure these products to a structural membrane rafter or purlin at least 1.5 inches deep. Berger Building Products, Inc (BBPI) snow guards are devices that are attached to the roof structure in order to provide uniform retention and control the snow from avalanching in large sheets. The snow guards need to be applied in sufficient quantity according to a prescribed pattern in order to be effective. Snow Guards are intended to reduce snow movement and provide for a controlled melt and breakdown of the snow mass into smaller sections. Snow guard placement will vary from region to region and will be influenced by roof pitch, the lengths of roof runs and roof features. Local installation customs may not be the best guide for placement. Additional information can be found in Sheet Metal and Air Conditioning Contractors' National Association (SMACNA) architectural sheet metal manual. Ultimately a qualified professional should determine placement. Use Of Snow Guards On Low -Slope Roofs Snow guards help slow the momentum of a potential snow slide. On low -slope roofs (those with pitches less than 3:12), snow does not typically slide off in the same manner. Under these circumstances, it is often better to allow the snow to naturally clear itself from the roof as quickly as possible or to manually remove it if needed. Therefore, snow guards are not recommended for low -slope roof applications. Check with the roof manufacturer for specific product application limits and observe roof safety guidelines. *Snow Guard Pattern Requirements Typical For Shingled Roofing Berger will provide a custom snow guard pattern recommendation. Please contact us at 800 - 523 -8852 for your custom layout. Snow guard patterns provided by Berger are only recommendations. Actual snow guard patterns should be approved by a licensed architect. RIDGE (Top of Roof) 6 to 8 ft. 2nd group same as 1st between groups group with spacing pattern reversed as shown X X X X X X X X X X X X X X 2nd group should be approx. 6 to 8ft. X X X X X X X X X X X X X X X from 1st group; additional 3rd row is same as 1st row. groups may be needed Up 15 in. or X X X X X X X X X X X X X X depending on overall 2 rows of shingles length of run. 6to8ft. 2nd row stagger 15 in. between groups over central to 1st row, and 15 in. up roof or 2 rows of shingles above fat row X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Start 1st row at or above exterior X X X X X X X X X X X X X X X load bearing wall EAVE (Bottom of Roof) Positioning of Berger snow guards required for effective use: 1 every 40 inches over entire roof, or 2 groups of 3 staggered rows on 30 inch centers with 1 group at the eave and 1 group midway on roof slope. On long slopes, multiple groups with 6 ft. space separation maximum. Snow guards should never be placed beyond the bearing wall on an extended roof section. This can result in ice damming and cause structural damage. Berger Building Products, Inc (BBPI) warrants that the products it manufactures shall be free from material defects. Should any of the products prove defective, the obligation of BBPI under this warranty shall be limited to replacement of the defective product or at our option the cost of the product originally shipped by Berger. This warranty is expressly in lieu of all other warranties expressed or implied including the warranties of merchantability and fitness for a particular purpose. There are no warranties, which extend beyond the description on the face hereof. BBPI in no event, whether claim is based on warranties, contract negligence or otherwise, is liable for incidental or consequential damages. Berger Building Products, Inc (BBPI) will not be responsible for misapplication or modification of product, incorrect material or defects that were obvious at time of installation. Any consequential damage, schedule delays, additional labor, and or equipment rental costs will not be BBPI responsibility. Any BBPI product warranty claim is limited solely to Berger Building Products, Inc. (800) 523 -8852 Fax (215) 355 -7738 www.bergerbuildingproducts.com BERGER Quality Building Products Since 1874 Page 14 SNOW GUARD 809 TECHNICAL INFORMATION Snow Guard Guidelines DETERMINING THE PROPER AMOUNT OF TORQUE FOR SET SCREWS will vary depending on the type and gauge of metal roofing. The recommended method for determining proper torque is to install one unit first, with blade on the uphill side. After tightening the set screws, loosen and remove the unit, inspecting the indentations created in the seam to see that proper compression was obtained. Remember, the screw closest to the blade is the real workhorse as it derives its strength from the blade, and if extra torque is needed, apply it to this screw. WHEN MECHANICALLY FASTENING SNOW GUARDS, use sealant or neoprene washers to ensure watertight seals. It is imperative to secure these products to a structural membrane rafter or purlin at least 1.5 inches deep. Berger Building Products, Inc (BBPI) snow guards are devices that are attached to the roof structure in order to provide uniform retention and control the snow from avalanching in large sheets. The snow guards need to be applied in sufficient quantity according to a prescribed pattern in order to be effective. Snow Guards are intended to reduce snow movement and provide for a controlled melt and breakdown of the snow mass into smaller sections. Snow guard placement will vary from region to region and will be influenced by roof pitch, the lengths of roof runs and roof features. Local installation customs may not be the best guide for placement. Additional information can be found in Sheet Metal and Air Conditioning Contractors' National Association (SMACNA) architectural sheet metal manual. Ultimately a qualified professional should determine placement. Use Of Snow Guards On Low -Slope Roofs Snow guards help slow the momentum of a potential snow slide. On low -slope roofs (those with pitches less than 3:12), snow does not typically slide off in the same manner. Under these circumstances, it is often better to allow the snow to naturally clear itself from the roof as quickly as possible or to manually remove it if needed. Therefore, snow guards are not recommended for low -slope roof applications. Check with the roof manufacturer for specific product application limits and observe roof safety guidelines. *Snow Guard Pattern Requirements Typical For Shingled Roofing Berger will provide a custom snow guard pattern recommendation. Please contact us at 800 - 523 -8852 for your custom layout. Snow guard patterns provided by Berger are only recommendations. Actual snow guard patterns should be approved by a licensed architect. RIDGE (Top of Roof) 6 to 8 ft. 2nd group same as 1st between groups group with spacing pattern reversed as shown X X X X X X X X X X X X X X 2nd group should be approx. 6 to 8ft. X X X X X X X X X X X X X X X from 1st group; additional 3rd row is same as 1st row. groups may be needed Up 15 in. or X X X X X X X X X X X X X X depending on overall 2 rows of shingles length of run. 6to8ft. 2nd row stagger 15 in. between groups over central to 1st row, and 15 in. up roof or 2 rows of shingles above fat row X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Start 1st row at or above exterior X X X X X X X X X X X X X X X load bearing wall EAVE (Bottom of Roof) Positioning of Berger snow guards required for effective use: 1 every 40 inches over entire roof, or 2 groups of 3 staggered rows on 30 inch centers with 1 group at the eave and 1 group midway on roof slope. On long slopes, multiple groups with 6 ft. space separation maximum. Snow guards should never be placed beyond the bearing wall on an extended roof section. This can result in ice damming and cause structural damage. Berger Building Products, Inc (BBPI) warrants that the products it manufactures shall be free from material defects. Should any of the products prove defective, the obligation of BBPI under this warranty shall be limited to replacement of the defective product or at our option the cost of the product originally shipped by Berger. This warranty is expressly in lieu of all other warranties expressed or implied including the warranties of merchantability and fitness for a particular purpose. There are no warranties, which extend beyond the description on the face hereof. BBPI in no event, whether claim is based on warranties, contract negligence or otherwise, is liable for incidental or consequential damages. Berger Building Products, Inc (BBPI) will not be responsible for misapplication or modification of product, incorrect material or defects that were obvious at time of installation. Any consequential damage, schedule delays, additional labor, and or equipment rental costs will not be BBPI responsibility. Any BBPI product warranty claim is limited solely to Berger Building Products, Inc. (800) 523 -8852 Fax (215) 355 -7738 www.bergerbuildingproducts.com SNOW RETENTION SYSTEMS Page 6 8/09 Snow Meister Snow Guard Series for Metal X11 pcs. per On. These non - penetrating devices are for traditional double lock standing seam roofs 1.0" deep x .250" wide. They fit both 1' and 1 -112" high ,. BERGER 'A +M"J� Colors. Black E -Coat Epoxy Primer Cast Aluminum requires a final color coat by contractor. Painted Aluminum and Polished Bronze � Quality Building Products Since 1874 SNOW RETENTION SYSTEMS Page 6 8/09 4;' V. This heavy -duty snow guard is available in copper and stainless steel for corrugated, flat, slate and asphalt shingled roofs. The superior design of the Pro 100 includes a 1 -inch gusset that reinforces the shoe, which makes this snow guard 5 times stronger than traditional residential snow guards. The Pro 100 has been tested to withstand a 300 -pound point load at any location when applied to the gusset side of the shoe. Simply insert the slotted bar under the slate or shingle, engage a nail with one of the conveniently placed slots and pull to fully secure the bar. This style snow guard provides fast installation and is ideal for existing or new construction applications with asphalt shingled roofs. Stainless Steel Code I Price I Code I Price SGCP100 SGSP100 This is a modified Berger #100 Snow Guard. The #100 shoe is attached to a shorter, solid bar /strap, and is designed for easy installation on shingle roofs. Copper Stainless Steel l Code Price Code Price SGC100HP SGS100HP (800) 523 -8852 Fax (215) 355 -7738 www.bergerbuildingproducts.com Snow Meister Snow Guard Series for Metal X11 pcs. per On. These non - penetrating devices are for traditional double lock standing seam roofs 1.0" deep x .250" wide. They fit both 1' and 1 -112" high ,. seams. The symmetrical design rotates 180 degrees to match seam lock orientation. Painted Aluminum is available in Custom 'A +M"J� Colors. Black E -Coat Epoxy Primer Cast Aluminum requires a final color coat by contractor. Painted Aluminum and Polished Bronze � require extended lead time and are not subject to cancellation or return. `Polished Bronze is a non - stock, special order. ;e Apo r \ Mill Finished Cast Aluminum Painted Cast Aluminum Black E -Coat Primer Cast Alum. Polished Bronze Code Price Code Price Code Price Code Price Code U. S. Patent 6,499,259 SG -1 MF Price SG -1C SL -1 MF SG -1 EBK SL -1C SG -1 PBZ' SL -1 EBK 4;' V. This heavy -duty snow guard is available in copper and stainless steel for corrugated, flat, slate and asphalt shingled roofs. The superior design of the Pro 100 includes a 1 -inch gusset that reinforces the shoe, which makes this snow guard 5 times stronger than traditional residential snow guards. The Pro 100 has been tested to withstand a 300 -pound point load at any location when applied to the gusset side of the shoe. Simply insert the slotted bar under the slate or shingle, engage a nail with one of the conveniently placed slots and pull to fully secure the bar. This style snow guard provides fast installation and is ideal for existing or new construction applications with asphalt shingled roofs. Stainless Steel Code I Price I Code I Price SGCP100 SGSP100 This is a modified Berger #100 Snow Guard. The #100 shoe is attached to a shorter, solid bar /strap, and is designed for easy installation on shingle roofs. Copper Stainless Steel l Code Price Code Price SGC100HP SGS100HP (800) 523 -8852 Fax (215) 355 -7738 www.bergerbuildingproducts.com Snow Meister Snow Guard Series for Metal X11 pcs. per These non - penetrating Cast Aluminum devices are for single lock T seam roofs 1.0' deep x .575' wide. The symmetrical design ,. rotates 180 degrees to match seam lock orientation. Painted Aluminum is available in Custom Colors. Black E -Coat Epoxy Primer A Cast Aluminum requires a final color coat by contractor. Painted Aluminum requires an extended lead time and is not subject to � cancellation or return. Mill Finished Cast Aluminum Painted Cast Aluminum Black E -Coat Primer Cast Aluminum ? Code Price Code Price Code Price U. S. Patent 6,499,259 SL -1 MF SL -1C SL -1 EBK 4;' V. This heavy -duty snow guard is available in copper and stainless steel for corrugated, flat, slate and asphalt shingled roofs. The superior design of the Pro 100 includes a 1 -inch gusset that reinforces the shoe, which makes this snow guard 5 times stronger than traditional residential snow guards. The Pro 100 has been tested to withstand a 300 -pound point load at any location when applied to the gusset side of the shoe. Simply insert the slotted bar under the slate or shingle, engage a nail with one of the conveniently placed slots and pull to fully secure the bar. This style snow guard provides fast installation and is ideal for existing or new construction applications with asphalt shingled roofs. Stainless Steel Code I Price I Code I Price SGCP100 SGSP100 This is a modified Berger #100 Snow Guard. The #100 shoe is attached to a shorter, solid bar /strap, and is designed for easy installation on shingle roofs. Copper Stainless Steel l Code Price Code Price SGC100HP SGS100HP (800) 523 -8852 Fax (215) 355 -7738 www.bergerbuildingproducts.com 03 -27 -2012 Inspection Request Reporting ' Page 6 4:10 pm Vail, C_ Of Wjj 0'60 Requested Inspect Date: Wednesday, March 28 2012 Site Address: 1815 GORE CREEK DID VAIL BOTH HALVES A/P /D Information Activity: B11 -0220 Type: COMBO Sub Type: ADUP Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: WELLES, DAVID EDWIN Contractor: PARADISE DEMOLITION Phone: 970 - 904 -0173 Description: REPLACING WOOD SHAKE ROOF WITH ASPHALT ARCHITECTURAL SHINGLE ON BOTH HALVES OF DUPLEX. Requested Inspection(s Item: 90 BLDG -Final Requestor: Comments: follow up Assigned To: J GON Action: 3 26 (?- A Inspection History Item: 90 BLDG -Final Time Exp: Requested Time: 03:00 PM Phone: Entered By: JMONDRAGON K REPT131 Run Id: 14281