HomeMy WebLinkAboutB11-0227NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 6 ,. mwN OFVAII Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: 1311 -0227 Project #: PRJ11 -0373 Job Address: 4295 NUGGET LN VAIL Applied.....: 07/26/2011 Location......: Issued...: 07/26/2011 Parcel No....: 210112306001 OWNER ROBERT C. MAYNOR JR TRUST 07/26/2011 JEFFREY DALE MAYNOR TRUSTEE 1405 DARNELL ST HUNSTVILLE AL 35801 APPLICANT JOHNNY ELECTRIC 07/26/2011 Phone: 970 - 376 -1463 CELL # P.O. BOX 3968 Avon CO 81620 License: 137 -E CONTRACTOR JOHNNY ELECTRIC 07/26/2011 Phone: 970 - 376 -1463 CELL # P.O. BOX 3968 Avon CO 81620 License: 137 -E Description: PULL NEW SERVICE TO REPLACE EXISTING Occupancy: Type Construction: Valuation: $6,000.00 .................................................. ............................... FEE SUMMARY Building Permit -- - - - - -> $125.25 Bldg Plan Check ----- - - - - -> $81.41 Use Tax Fee------------------ - - - - -> $0.00 Electrical Permit --- - - - - -> $287.50 Elec Plan Check ------ - - - - -> $186.88 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees ---------- – -------- > ($206.66) Plumbing Permit - - ---> $0.00 Plmb Plan Check - - - - -> $0.00 Recreation Fee ----- ---- ------- > $0.00 Investigation -------- ----- -------- > $0.00 Will Call --------------- — ---- – ------ > $5.00 TOTAL PERMIT FEES ------------ –> $479.38 Payments ------------------------ -- ----- > $479.38 BALANCE DUE --- – ------------ – ----- > $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TW NTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 _+ _u _- Sr ature of Owner or Contractor Date .SD tinn �, U"�SS Print NIame combination permit - 012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit* B11 -0227 Address: 4295 NUGGET LN VAIL Owner: ROBERT C. MAYNOR JR TRUST Location: combination permit-012811 TOWN OF VAILh REQUIRED INSPECTIONS AND STATUSES Permit* B11 -0227 Address: 4295 NUGGET LN VAIL Owner: ROBERT C. MAYNOR JR TRUST Location: Item: 00120 ELEC -Rough Item: 00190 ELEC -Final Item: 00090 BLDG -Final combination permit-012811 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R110000846 Amount: $479.38 07/26/201111:03 AM Payment Method: Check Init: JRM Notation: ----------------------------------------------------------------------------- Permit No: Bll -0227 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 123 - 0600 -1 Site Address: 4295 NUGGET LN VAIL Location: Total Fees: $479.38 This Payment: $479.38 Total ALL Pmts: $479.38 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- EP 00100003111100 ELECTRICAL PERMIT FEES 287.50 PF 00100003112300 PLAN CHECK FEES 186.88 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 t TOWN OF VAIC' y 00 c.ci ! [e_'._h Project #: V CL AS BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: ' 4 L.v (aumber) (Street) (Suite #) Building /Complex Name: Contractor Information {{ Business Name: 'Cl'eak "' / Business Address: L2 ^ee ;Pt` City State: CL') Zip: 91631 Contact Name:, �T'04^' L[ G/ Contact Phone: C70 _ 3 - 1'W 3 Contact E -Mail: Jbkhh aK'm LfGe - " �A-C_ •CoN1 X Owner /Owrr Representative Signature (Required) Applicant Information DRB #: 1 -- k " t Building Permit #: U k — u 2?_- Lot #: Block # Subdivision: Work Class: New ( ) Addition ( ) Alteration ( Type of Building: Single - Family Z ) Duplex( ) Multi - Family ( ) Commercial( Other( ) Work Type: Interior ( ) Exterior Both ( ) ical Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 www.vailgov.com Development Review Coordinator Valuation of Work Included Plans Included Work ( Yes ( )No ()()Yes ( )No 6OA0.Oa ( )Yes ( )No ( )Yes ( )No ( )Yes ( )No ( )Yes ( )No ( )Yes ( )No ( )Yes ( )No Applicant Name: 5 AX4, QC C, , Z6d%/.L_ f Plumbing Applicant Phone: Applicant E -Mail: Project Information Owner Name: Parcel #: 2 10 t 1 06 00 1 (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www. ea g I ecou nty. us /patie) Value of all work being performed: $ (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage Detailed Scope and Location of Work: &1i Iv 5 e , 6 - ,, ty rPplots c)(i (use additional sheet if necessary) For Office Use OnC /.y - Fee Paid: T. Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Ar _n G Date Received: (p�CECnIEOWIE(� JUL 25 2011 IUI TOWN OF VAIL 01 -Jan -I 1 Free NEC Electrical Load Calculation Software ZenFixit! Free NEC Electrical Load Calculator Home >Site Map >Safety! >Contact Me! > Page 1 of 4 Don't see What you were looking for? Search This Site... ► Pirl_ search Search Is by G000le Load Calc Calculation HVAC Load Electrical Wiring Load Measurement NEC Standard Method Single Family Residential - Electric Service Entrance Load Calculator Enter plain numbers in cells without text or labels. If you leave any cells empty they will be calculated as zero. Total Square feet of dwelling 2650 Total # of Small Appliance Branch circuits (must be at least 2). If you have gas appliances which require a 120v branch circuit include them here. i 2 Total # of Laundry Branch circuits (must be at least 1) 1 Fastened in place Electrical appliances - Do not include gas appliances in this section. Use nameplate rating in volt -amps or watts - If appliance is rated in amps then volt -amps = amps * volts. Voltage value is either 120 or 240. So, for a 120 volt appliance which is rated at 15 amps, 120 volts * 15 amps = 1800 volt -amps. Total # of water heaters 1 Volt -amp rating of water heater 4500 Total # of trash compactors Volt -amp rating of trash compactor 1500 Total # of dishwashers Volt -amp rating of dishwasher 1200 Total # of disposals 1 Volt -amp rating of disposal 900 � JUL 2 2011 TOWN OF VAIL Total # of microwave ovens 1 What's the Difference between Watts and Volt -Amps? Volt -amps as the name implies = volts amps, but watts also = volts * amps, so what is the difference? Volt -amp ratings represent a maximum value, whereas Watt ratings are more like an average value over time. For some appliances both ratings have the same value, and for others there is a large difference. Imagine an oven that draws lots of current while it is preheating, but then may use very little for several minutes at a time once it is heated up. When there is a difference then volt -amps will be the larger . of the two, and the ratio of watts /volt -amps is called the power factor, and is represented as either a decimal (0.8) or a percentage (80 %). Confused? Don't sweat it, just use which ever value is on the appliance name plate or the larger of the i two in the rare case that both might be listed. http:// www. zenfixit .com/load_calculations.shtml 7/25/2011 Free NEC Electrical Load Calculation Software Page 2 of 4 Volt -amp rating of microwave oven 1500 Total # of range hoods 1 Volt -amp rating of range hood 600 Other fastened in place appliances - use this section to define things like spas which aren't specified above. Total # of other fastened in place appliance #1 0 Volt -amp rating of other fastened in place appliance #1 Total # of other fastened in place appliance #2 0 Volt -amp rating of other fastened in place appliance #2 Total # of other fastened in place appliance #3 0 Volt -amp rating of other fastened in place appliance #3 Total # of clothes dryers 1 V olt -amp rating of clothes dryer (must be at least 5000) 5000 Total # of Ranges 1 Volt -amp rating of Range 10000 Total # of Ovens - Note: If there is a range, and no additional oven then don't put anything here. 1 Volt -amp rating of Oven 3000 Total # of Cooktops - Note: If there is a range, and no additional cooktop then don't put anything here. 0 Volt -amp rating of Cooktop 6000 http: / /www.zenfixit.com/load calculations. shtml 7/25/2011 Free NEC Electrical Load Calculation Software Page 3 of 4 Total # of Other cooking appliance over 1750 volt -amps Volt -amp rating of Other cooking appliance over 1750 volt -amps 12000 Volt -amp rating of Larger of Heating OR Air conditioning system - always include air handler. For heat pump include compressor and the maximum amt of electrical heat that can be energized while compressor is running. 10000 Voles rating of Largest Single Motor (usally the HVAC compressor or air handler motor) 800 Service voltage is assumed to be 240 Calculate Load This is a simple free program for calculating electrical load for single family residential dwellings. This calculation determines the size of your electric service entrance (and meter) and main electrical panel based upon your potential load usage. If you are thinking about adding on or building a new house, then this calculator will help you to determine if your existing entrance is big enough or if you will have to spend a considerable amount to upgrade. Your local codes department will probably let you use a larger service entrance than the minimum if you want (up to a point), but you can't (and don't want to) have one that is even a little bit too small. This program calculates total service load based upon the 2005 National Electrical Code Article 220. A balanced load is assumed. Note: This program makes quick work of a lengthy calculation. In many cases you can use the values for volt -amp nameplate ratings that are provided and you will still get pretty good results (as an estimate only). Also this program does not have any provisions for usage allocation in the case of multiple major appliances circuits, so you will notice that if you input that the dwelling has more than one dryer circuit for example (maybe one in the basement and another in a main floor utility area) then it will show that you need to have a much bigger service entrance, but this isn't really correct in all cases because the code recognizes that you probably don't usually have a dryer plugged into both of them at the same time. If however, you have a second dryer outlet in an area of the house which might be used as a separate habitation the inspector will probably count the extra appliance circuit against the total load, and make you get a bigger entrance, because of the likely potential for simultaneous use - for example if the basement not only has a dryer plug, but also it's own full bath and a kitchenete area, and an exterior entrance. When in doubt, contact your local codes authority before you do anything expensive. Table 310.15(6) Conductor Types and Sizes for 120 /240 -Volt, 3 wire, Single Phase Dwelling Services and Feeders. Conductor Types RHH, RHW, RHW -2, THHN, WHHW -2, SE, USE, USE -2 http:// www. zenfixit .com/load_calculations.shtml 7/25/2011 Service Copper Copperor Copper or Feeder clad rating Aluminum in Amperes �n�n 100 �n�n 110 1/0 � 125 n 2/0 — �nr� � 150 inn http:// www. zenfixit .com/load_calculations.shtml 7/25/2011 Free NEC Electrical Load Calculation Software uu�u 3/0 � 250 � 225 4/0 � 300 � 250 250 � 350 � 300 350 � 500 � 350 400 � 600 � 400 Site Map http://www.zenfixit.com/load Page 4 of 4 7/25/2011 Results for Load Calculations Page 1 of 1 Results for Load Calculation / 6-2,.2u P� Minimum Service Entrance Size = Round up to standard size for service entrance. Use your back button to try again. np— http:// www .zenfixit.com/load.php ?squareft= 2650 &smallapps =2 &laundrys = l &al =1 &al w... 7/25/2011 08 -01 -2011 Inspection Request Reporting Page 12 4:41 Dm Vail, CO - City Of Requested Inspect Date: Tuesda , Auggust 02, 2011 Site Address: 4295 N�GGET LN VAIL A/P /D Information Activity: B11 -0227 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: ROBERT C. MAYNOR JR TRUST Contractor: JOHNNY ELECTRIC Phone: 970 - 376 -1463 CELL # Description: PULL NEW SERVICE TO REPLACE EXISTING Reauested Inspection(s Item: 190 ELEC -Final Requestor: Comments: 376 -1463 Assigned To: S R Action: Time Exp: V' Requested Time: 08:00 AM Phone: Entered By: MHAEBERLE K Insaection Histo Item: 120 ELEC -Rough ** Approved ** 07/28/1 T Inspector: sgremmer Action: AP APPROVED Comment: Service and underground Item: 190 ELEC -Final Item: 90 BLDG -Final R£PT131 Run Id: 13372