HomeMy WebLinkAboutF11-0038 CUT SHEETS11 Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpnVW Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent /F1 3. F1 Res 49 Recessed Pendent /FP 4. F1 Res 49 CCP Pendent 5. F1 Res 58 Pendent 6. F1 Res 58 Recessed Pendent /F1 7. F1 Res 58 Recessed Pendent /FP 8. F1 Res 58 CCP Pendent 9. F1 Res 44 & 58 HSW 10. F1 Res 44 & 58 HSW Recessed HSW /F2 11. F1 Res 44 SWC 12. F1 Res 76 Pendent 13. F1 Res 76 Recessed Pendent /F1 14. F1 Res 76 Recessed Pendent /FP 15. F1 Res 76 CCP Pendent Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258 -93 -E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers Product Description Model F1Res Pendent sprinklers (Figs. 1, 2, 3 & 4) combine excellent durability, high sensitivity glass -bulb and low profile decorative design. The 3mm glass -bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow F1 Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard *). Upon fire conditions, rising heat causes a sprinkler's heat - sensitive glass -bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. F1 Res 44 & 58 Recessed HSW/F2 F1 Res 44 SWC Technical Data: • Thermal Sensor: Nominal 3mm glass -bulb • Sprinkler Frame: Brass Casting • Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: 1 12 ' NPT 91/2) • KT 4.9 (AcLo - F1 Res 49 Pendal Spnnkler 5.8 (Actual) - F1 Res 58 Pendant & HSW SpriW 7.6 (Actual) - F1 Res 76 Pendent Sprinkler 4.4 (Actual) - F1 Res 44 HSW Sprinkler • Density: Minimum 0.10 gprr Residential Sprinklers for Design Density of .10 gpm/ft Bulletin 176 Rev. A F1 Res 49,58 & 76 F1 Res 49,58 & 76 Recessed Pendent/ F1 Recessed Pendent /FP F1 Res 49, 58 & 76 CCP Pendent * Effective date 7/12/02 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 Res Sprinklers are used for Residential Fire Protection according to UL 1626 Standard *. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. When using F1 Residential Sprinklers for systems design to NFPA 13D or NFPA 13R, use listed area of coverage and minimum flow and pressure requirements shown in Bulletin 135. For systems designed to NFPA 13, use information in this bulletin. The number of design sprinklers shall be the most hydraulically demanding sprinklers as required by NFPA 13. Flows and pressures can not be below the baseline flows and pressurers. NFPA 13 For residential sprinkler systerris designed to NFPA 13, a minimum density of 0.1 gpm /ft must be provided over the "design area" that includes the four (4) hydraulically most demanding sprinklers for the actual coverage areas being protected by the 4 sprinklers. The minimum required discharge from each of the four most hydraulically demanding sprinklers shall be the greater of the following: 1.The flow rates given in the Reliable Residential Sprinkler Technical Bulletins referenced in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area (for actual coverage areas less than or between those indicated in the respective technical bulletin, it is required to use the minimum required flow for the next largest coverage area); or 2.A minimum discharge density of 0.1 gpm/ft 2 applied over the "design area" consisting of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. The maximum dimension of the actual coverage area cannot be any greater than the maximum coverage area indicated in the technical bulletins referenced in Table A. Design Note: Using the A = S x L method to determine the sprinkler protection area of coverag-9 in accordance with NFPA 13, apply the 0.1 gpm /ft density to this area to determine the minimum required flog. Compare this flow to the minimum 0.05 gpm /ft cULus Listed flow for the appropriate coverage area in the technical bulletin for the specific residential sprinkler. If the flow stated in the techni al bulletin is less than the calculated 0.1 gpm /f' density flow required, the .1 density flow must then be used in the equation Q =KVP, solving for P, to establish the minimum required pressure using the sprinkler K- factor. Note: In many cases the listed flow of individual residential sprinkler may exceed the required minimum 0.05 gpm /ft density. Reliable has available residential sprinklers with larger K- factors (K =5.8 and K =7.6) that wi provide lower pressure demands for 0.1 gpm /ft densities in NFPA 13 residential applications. Example No. 1 Room Size= 12 ft x 20 ft (3.6 m x 6.1 m) Coverage Area= 12 x 20 = 240 ft (22.3 m 2 ) Flow @ 0.10 gpm /ft density= 240 x 0.10 = 24 gpm Using an F1 Res 49 Pendent Sprinkler, K =4.9 Pressure= (24/4.9) = 24 psi (1.65 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) coverge area using the baseline density of 0.05 gpm /ft will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, the minimum flow required is 24 gpm @ 24 psi (90.8 L/min @ 1.65 bar). Example No-2 Room Size= 8 ft x 20 ft (2.4 m x 6.1 m) Coverage Area= 8 x 20 = 160 ft (14.9 m 2 ) Flow @ 0.10 gpm /ft density= 160 x 0.10 = 16 gpm Using an F1 Res 49 Pendent Sprinkler, K =4.9 Pressure= (16/4.9) = 10.7 psi (0.74 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) coverye area using the baseline density of 0.05 gpm /ft will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, the minimum flow required is 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Example No. 3 Room Size= 10 ft x 16 ft (3.0 m x 4.91 m) Coverage Area= 10 x 16 = 160 ft (14.9 m 2 ) Flow @ 0.10 gpm /ft density= 160 x 0.10 = 16 gpm Using an F1 Res 76 Pendent Sprinkler, K =7.6 The baseline flow for a 16 ft x 16 ft coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 Umin @ 0.52 bar). Example No. 4 Room Size= 14ftx 18ft (4.3mx5.5m) Coverage Area= 14 x 18 = 252 ft (23.6 m 2 ) Flow @ 0.10 gpm /ft density= 252 x 0.10 = 25.2 gpm (94.6 L/min) Using an F1 Res 76 Pendent Sprinkler, K =7.6 Pressure= (252/7.6) = 11 psi (0.76 bar) The baseline flow and pressure of an 18 ft x 18 ft coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 25.2 gpm @ 11 psi (94.6 L /min @ 0.76 bar). In general residential sprinklers require flows and pressures as listed for 0.05 densities to achieve the proper spray pattern so the flows and pressures at 0.05 density are the baseline flows and pressures. Flows and pressures below the listed 0.05 density shall not be used. 2. Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model F1 Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 Res recessed HSW sprinklers • Model F1 Res 49, 58 & 76 Pendent use only the Model GFR2 Sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Note: A'leak tight" sprinkler joint can be obtained with the following torque: • 3 /4 " NPT (R3/4) - 14 -20 ft-Ibs (19 - 27.1 N -m) • 1 /2 " NPT (R1/2) - 8 -18 ft -Ibs (10.8 - 24.4 N -m) Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. • Model F1 Res 49, 58 & 76 Recessed Pendent/ F1 /1 n � ol _ w� F1 escutcheon, /" (19mm) adjustment 1.35FCO3 Fig, 1 Note: See escutcheon table for dimensions. 2 1 /.' IIOLC 04 (5 -1 1 15/16' Dw. 1 • X 1 12' RE fI 4. RJRN C UMIL )ACMI A 6O S, SPRMx([R WRENCH @OSS. 1 I EACE nmNC 10 _ cExn+C DMl[l/SIOM J/16 -15/16 (F1 ESCUICIEON) J fY / / // / evu�vv 3116 -11/16 (f2 CSCUICNEON) 4AN5l,1EN, 4NaYa 1/6 (,.2m i 135FO02A 2 27132' DK [72.2 -1 Fig. 2 3. Technical Data: F1 Res 49 Pendent and Recessed Pendent Nominal Sprinkler Max, Max. Inch (mm) Inch (mm) Sprinkler Thread Orifice Temp. Pressures Ambient Actual ht Len S he Inch Rati 17 64.3 Tem Factor Inch 16.7(l 14) (mm) OF °C l °F °C '' /z" NPT ( R 1 /2) (mm) Y,11 � T '' /'s (11) 151 7 69 175 (12) 150 1 66 4.9 2.25 (57) Escutcheon *. F1 or F2. Data: T yp e Adjustment "A" Face of fitting to ceili Sprinkler Identification Number (SIN R3516 Inch (mm) Inch (mm) Inch (mm F1 %(19.0) Min. =Y (19.1) Max. =1' " (38.1) / _,/ (4.7 -24.0) B F2 % (12.7) Min.= 1 %" (23.8) Max. =1' " 38.1 ' /,s _, (4.7 - 17.4) " Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 & 58 Recessed Pendent Sprinkler * *Baseline flows and pressures for 0.05 density Deflector - to - ceiling Maximum 1" (25mm) to 4" (100mm) Max. Sprinkler Spacing ft m Flow m (Lm) 9Pp Pressure p sl (bar) Sprinkler Identification Number (SIN R3516 12 x 12 3.6x3.6 13 49 7.0 0.48 14 x 14 4.3x4.3 13 49 7.0 0.48 16 x 16 4.9x4.9 13 49 7.0 0.48 18 x 18 5.5x5.5 17 64.3 12.0 0.83 20 x 20 (6.14.1) 20 (75.7) 16.7(l 14) *Deflector - to - ceiling Maximum 4 00mm) to &' (203mm) Max. Sprinkler Spacing ft m Flow 9Pm (Lpm) Pressure psi (bar) Sprinkler Identification Number SIN R3516 12 x 12 (3.6x3.6) 15 57 9.4 0.65 14 x 14 4.3x4.3 16 60.5 10.6 0.73 16 x 16 4.9x4.9 17 64.3 12.0 0.83 18 x 18 5.5x5.5 19 72 15.0 1.0 20 x 20 6.1 x6.1 22 83.2 20.2(l.4 "Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7" (178mm) 2. Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent * *Baseline flows and pressures for 0.05 density Max. Sprinkler Nominal Sprinkler Max. Max. Sprinkler Thread Orifice Temp. pressure Ambient K Length Size Inch Rail no psi Tem P. Factor Inch OF I °C 16 61 (mm) (bar) OF °C (mm) '' /z" NPT ( R 1 /2) /. (13) 155 175 68 79 175 (12) 100 150 38 5.8 66 2.25 (57) * *Baseline flows and pressures for 0.05 density Max. Sprinkler Flow Pressure Ceiling -to- Sprinkler Spacing gp m ( L p m ) ( ) r bar Deflector Identification ft m 7.6 0.53 Inch mm Number SIN 12 x 12 3.6x3.6 16 61 (25- 00) R3513 14 x 14 43x4.3 16 61 7.6 0.53 16 x 16 4.9x4.9 16 61 7.6 0.53 18 x 18 5.5x5.5 19 72 10.8 0.75 20 x 20 (6.1 x6.1) 22 (83.3) 14.4 (1.0) "Calculate for a .10 density but in no case go below the baseline flows & pressures 4. Technical Data: F1 Res 76 Pendent and Recessed Pendent • Model F1 Res 49, 58 & 76 Pendent D 2 518" [66.7mm] DIA. 2 5/16" DIA, HOLE IN CEILING (58.7mm) CUP 1- _ . 1 --- '�� - - - "' 1 ° x1/2" REDUCER CUP \\ I 4 CEILING �— - MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION COVER ADJUSTMENT I HEIGHT 3 5116" DIA. 7 35FG04C [84.1 mm) F1 RES 49. 58 & 76 CCP PEND. Fig. 3 NOTE: The F1 Res 76 will use a 1" x 3 /" reducer. • Model F1 Res 49, 58 & 76 Recessed Pendent/ FP u- FP push -on /thread -off escutcheon 2 518 Du. [66.7mm] HOLE IN CEILING AAmc -- - Sprinkler (5 &7-1 CUP Thread Orifice � Pressure Ambiert L ength K I I - --1--- -- I X I / ?' REDUCER Size Inch I psi T Facbr Inch m NAx. ` - -- - EACE or EImNc 0 r0 CE OE GELLING (mm) °F °C (bar) °F °C - AQ/USrA1ENr (mm) %" NPT (Rj , Y32' (13 5) 155 175 68 1 79 100 150 38 66 7.6 2.25 (57) T YPe Adjustment " Face of fitting to ceiling -- , _ Inch (mm) Inch (mm) Inch (mm) * ase ine ows an ressures for 0.05 den P F1 3, ( 9 .0) IMi�= 1 N (38.1) %6 - ' %6 (4.7 - 24.0) Max. Sprinkler _ - - -- sprinkler SItY F2 '/z (12.7) Min.= l% (23.8) Max. -1/" 38.1) %6 -,, ,6 (4.7-17.4) Spacing Flo ° Pressure .. . Identification ft m 9Pm (Lpm) psi (bar) Number SIN 12x12 3.6x3.6 21 76(0.53) 14 x 14 4.3x4.3 21 7.653) 16 x 16 4.9x4.9 21 7.6 0.53 R7618 *Calculate for a .10 density but in no case 18 x 18 5.5x5.5 21 7.6 (0.53) go below the baseline flows & pressures 20 x 20 (6.1x6.1) 23 9 2 (0.63) • Model F1 Res 49, 58 & 76 Pendent D 2 518" [66.7mm] DIA. 2 5/16" DIA, HOLE IN CEILING (58.7mm) CUP 1- _ . 1 --- '�� - - - "' 1 ° x1/2" REDUCER CUP \\ I 4 CEILING �— - MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION COVER ADJUSTMENT I HEIGHT 3 5116" DIA. 7 35FG04C [84.1 mm) F1 RES 49. 58 & 76 CCP PEND. Fig. 3 NOTE: The F1 Res 76 will use a 1" x 3 /" reducer. • Model F1 Res 49, 58 & 76 Recessed Pendent/ FP u- FP push -on /thread -off escutcheon 2 518 Du. [66.7mm] HOLE IN CEILING 2 5116 ON. (5 &7-1 CUP I I - --1--- -- I X I / ?' REDUCER I J aN 1/JG m NAx. ` - -- - EACE or EImNc 0 r0 CE OE GELLING \` DIMENSION 112 [13-] -X. - AQ/USrA1ENr A I Fig. 4 5. Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent / FP *Baseline flows and pressures for 0.05 density FP Data ..A,,: Max. Sprinkler Flow Spacing ft W gpm (Lpm) 12 x 12 3.6x3.6 13 49 r- -- Sprinkler Identification Number (SI 7.0 0.48 R3516 14 x 14 4.3x4.3 CCP Options Dat 7.0 0.48 16 x 16 4.9x4.9 NorNnal Sprinkler OCP A�tlbll/ NWC Max 20x20 6.1x6.1 ni "A" 16.7 1.14 Inch Thread orifice Temp. T � Pressure Ambient K �� Cover Adjustment (bar) H CCP Height She InCh R*rg T� F hch Inch mm oC Inch_ (mm) of (mm) of °C , ,C (bar) of °C 57 (m m) / 12.7 38 5 24 Y(RNPT ' % (11) 155 1 68 l 135 57 1 175 (12) 100 38 4.9 57 s 4.7 s 19 *Baseline flows and pressures for 0.05 density FP Data ..A,,: Max. Sprinkler Flow Spacing ft W gpm (Lpm) 12 x 12 3.6x3.6 13 49 Pressure psi (bar) Sprinkler Identification Number (SI 7.0 0.48 R3516 14 x 14 4.3x4.3 13 49 7.0 0.48 16 x 16 4.9x4.9 14 53 8.2 0.56 18 x 18 5.54.5 18(68.1 13.5 0.93 20x20 6.1x6.1 20 75.7 16.7 1.14 FP Position ..A„ Inch mm Max. Recessed Y16 11 Min. Recessed 1 24 Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP *Baseline flows and pressures for 0.05 de nsity Max. Sprinkler Flow Spacing gpm (Lpm) Nominal Sprinkler ccP AY MML I Max R3513 SpMdw Thread Orifice TUTP T aT41 Pressure Arnllient K Length Size Inch RlAng 57 psi Temp. Factor hd1 2.25 (57 (mm) °F (bar) (MM) of °C oC of IC NPT R /z '/i (13) 155 68 135 57 175 (12) 100 38 5.8 2.25 (57) *Baseline flows and pressures for 0.05 de nsity Max. Sprinkler Flow Spacing gpm (Lpm) Pressure psi (bar) Sprinkler Number N' 12 x 12 3.6x3.6 16 61 7.6 0.53 R3513 14 x 14 4.3x4.3 16 61 7.6 0.53 16 x 16 4.9x4.9 16 61 7.6 0.53 18 x 18 5.5x5.5 19 72) 10.8 0.75 1 20x 20(6.14.1) 22(833) Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Nominal SpriidNa�� Max Max Spdrida Thread Orifice TemR Size Inch Railing (mm) °F °C T Pressure yob psi °F °C Ambient Teri¢ K Fackm Levillh (rim) °F °C 3 /," NPT (R3 /� '%z (13.5 155 175 68 79 135 57 1 17,5(12) 100 150 _ 38 66 7 ' 6 2.25 (57 *Baseline f lows and Max. Sprinkler Flow Spacing ft m gpm(Lprn) 12 x 12 (3.64.6 ) 21 14 x 14 4.3x4.3 21 _ 16 x 16 4.9x4.9 21 18 x 18 5.5x5.5 22 20 x 20 (6.1 x6.1) 25 ressures for 0.05 density Pressure Sprinkler psi (bar) Identification Number SIN 7.6 0.53 7.6 0.53 7.6 0.53 R7618 8.4 0.58 10.8 (0.74) *Calculate for a .10 density but in no case go below the baseline flows & pressures A • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW /F2 F2 escutcheon, y" (13mm) adjustment Technical Data: F1 Res 44 HSW & HSW /F2 Escutcheon, F2, Data: Nominal ' Max. N1ax. Sprir�fder Thread Orifloe T� Pressure A K am Irtcht psi T Fkllor � (mm) OF c 1 (bar) cF °C (mm) Type Adjustment Face of�i ng Inch (mm) Inch mm F2 13 3 /, - 4.7- 17.4), 1 /2" NPT y• (10) 175 68 1 75 (12) 150 66 4.4 2.45 (62) *Baseline flows and pressures for 0.05 density 4 -6 (101 -152) A 16x18 4.94.5 15 18 x 18 5.54.5 Max. Sprinkler Ceiling -to- Sprinkler Temp. Flow Pressure Sprinkler Spacing Deflector Rating j gpm Psi (bar) Identification ft (m) Inch mm OF ( °C) (fpm) 17 64.4 Number (SIN) 12 x 12 (3.6x3.6 ) 20 75.7 155 68 175 79 12 45.4 -- 75(0.52 ) 14 x 14 43x4.3 155 (68) 175 (791 14 53.0 102(0-71 16x16 4.9x4.9 4 -6 (101 -152) 155 16x18 4.94.5 15 18 x 18 5.54.5 155 16 x 20 4.9x6.1 155 12 x 12 3.6x3.6 6-12 (152 -305) 155 14 x 14 43x4.3 155 16 x 16 4.9x4.9 155 16 x 18 4.94.5 155 16 x 20 (4.9x6.1) 155 175 (79) 16 60.6 13.3 0.92 R3531 175 79 18 68.1 16.8 1.16 175 79 19 72.0 18.7(l.29 175 79 23 87.1 27.4(l.89) 175 79 14 53.0 10.2 0.71 175 79 16 60.6 13.3 0.92 175 79 17 64.4 15.0 1.04 175 79 20 75.7 20.7 1.43 175 (79) 23 (87.1) 27.4 (1.89) 'Calculate for a .10 density but in no case go below the baseline flows & pressures 7. Model F1 Res 44 SWC N, 1 rMM a' to 12' 1101,60mm To 1 1 1e' (31.75mm] Maximum 30e.80mm] Face Of Fitting TURN TO COVER THEN , To Wall Dimension TURN 0 ADJUST UNTIL P� TIGHT AGAINST WALL. 1' X 1/2' Reducer Recommended ,1 " Wou H.I. 2 5116' 2 518' (58.7imm] - -- - - -�- 3 5116' [66.58mm] DA.. ' Dio. [Be. A., TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER `' 21 1 32' WRENCH BOSS. / (e2.07mm] usrc6T 112' [12.70mm] Adjustment F1 RES 44 SWC Fig, 5 Technical Data: F1 Res 44 SWC Nominal Sprinlder CMWT Max, Max. Spri-ider Thread Orifice Temp. Rah y RMSS.Lfe anjjmtTemp Factor hd Sho Inch (mm) F IC 9 C (bar) (mm) Iz(R1)T %" (10) 155 68 135 57 175 (12) 100 38 4.4 2.45 (62) *Baseline flows and pressures for 0.05 density 'Calculate for a .10 density but in no case go below the baseline flows & pressures i Technical Data: F1 Res 58 HSW & HSW /F2 *Baseline flows and pressures for 0.05 density Max. Sprinkler Sprinkler Temp. Spacing Ceilin g -ton- Rating ft (m) Inch mm) OF (°C) Nominal Sprinkler Max. Max. (101-152) 155 68 Escutcheon, F2, Data: Sprinkl Ad'ustmtxK Face of Fitting Thread Orifice Temp. Pressure Ambient K Length Type Inch (mm) to wall Sbae Inch Ra1i psi Tem • Factor Inch Inch mm 16 x 20 4.9x6.1 (mm) °F °C (►ter) OF °C 5.8 (mm) 2.45 (62) F2 13 3 - 4.7 - 17.4 1 /2" NPT R'/2 %" ( 1 155 175 68 79 175 (12) 100 150 38 66 *Baseline flows and pressures for 0.05 density Max. Sprinkler Sprinkler Temp. Spacing Ceilin g -ton- Rating ft (m) Inch mm) OF (°C) ROW gpm (Lpm) Pressure psi (bar) Sprinkler ification Number (SIN) 12 x 12 3.6x3.6 (101-152) 155 68 175 (79) 16 60.6 7.6 (0.53 R3533 14 x 14 4.3x4.3 155 68 175 79 18 68.2 9.7 0.67 16 x 16 4.9x4.9 155 68 175 79 21 79.5 13.2 0.91 16 x 18 4.9x5.5 155 68 175 79 25 94.7 18.6(l.28 16 x 20 4.9x6.1 155 68 175 79 29 109.8 25 1.73 12 x 12 3.6x3.6 6-12 (152 -305) 155 68 175 79 22 83.3 14.4 1.0 14 x 14 4.3x4.3 155 68 175 79 22 83.3 14.4 1.0 16 x 16 4.9x4.9 155 68 175 79 26 98.4 20.1 1.39 16 x 18 4.9x5.5 155 68 175 79 31 117.4 28.6(l.97 *Calculate for a .10 density but in no case go below the baseline flows & pressures Finishes Standard Finishes Sprinkler F1 F2 FP Escutcheons Bronze Brass Chrome Plated Bright Chrome Plated White Pol ester Coated White Painted Special Appil cation Finishes Sprinkler F1 F2 Escutcheons Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 0 Maintenance Model F1 Res 49, F1 Res 58 & F1 Res 76 Sprinklers should be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non - operation. Model F1 RES 49 Residential Sprinkler Specifications Model F1 Res 49 & 58 Pendent Sprinklers shall be [cULus Listed] [New York City MEA Approved (258- 93 -E)] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector -to- ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a' /2' NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer and top - loaded extruded cup with 3 mm glass bulb containin no plastic parts, and having a temperature rating of T155 °F (68 0 C)] [175 °F (79 0 C)]. Sprinklers shall have a nominal K- factor of 4.9 & 5.8. Standard finish: [Bronze] [Chrome - plated] [White Polyester] [Special finish - specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 49 & 58, SIN R3516 & R3513 (Bulletin 135). Model F1 Res 49 & 58 Recessed Pendent/F1, Model F1 Res 49 & 58 Recessed Pendent/F2, Model F1 Res 49 & 58 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258- 93 -E)] low flow residential recessed pendent sprinklers engine red to provide a minimum design density of 0.10 gpm /ft'over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector -to- ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a' /2 NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer and top - loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155 °F (68 0 C)] [175 °F (79 0 C)]. Sprinklers shall have a nominal K- factor of 4.9 (70). Standard finish: [Bronze] [Chrome - plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1 /2" adjustment (Model F2)] [with 3 /d' adjustment (Model F1)] [of push -on and thread off design with 1 12 " adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 49 & 58 Recessed Pendent/Fl] [Model F1 Res 49 & 58 Recessed Pendent/F2] [Model F1 Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513 (Bulletin 135). Model F1 Res 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258- 93 -E)] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.10 gpm /ft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ' /z" NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer and top - loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155 °F (68 0 C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a 1 /2 " cover plate adjustment. Cover plate temperature rating shall be 135 °F (57 0 C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 49 & 58 CCP, SIN R3516 & R3513 (Bulletin 135). 10. Model F1 Res 44 & 58 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258- 93 -E)] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.10 gpm /ft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [4112] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 1 12" NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer and top - loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155 °F (68 0 C)] [175 °F (79 0 C)]. Sprinklers shall have a nominal K- factor of 5.8. Standard finish: [Bronze] [Chrome - plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model F1 Res 58, SIN R3513 (Bulletin 135). Model F1 Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two -piece escutcheon with 1 12 " adjustment (Model F2). Standard finish shall be [ brass][bright chrome] [white painted] [Special finish - specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 58/F2, SIN R3513 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.10 gpm /e over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3 /4" NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer and machined cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155 °F (68 0 C)] [175 °F (79 0 C)]. Sprinklers shall have a nominal K- factor of 7.6. Standard finish: [Bronze] [Chrome - plated] [White Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3 /4" NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer and machined cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155 °F (68 0 C)] [175 °F (79 0 C)]. Sprinklers shall have a nominal K- factor of 7.6. Standard finish: [Bronze] [Chrome - plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two -piece escutcheon [with 1 /2 " adjustment (Model F2)] [with 3 /4" adjustment (Model F1)] [of push -on and thread off design with 1 12 " adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/Fl] [Model F1 Res 76 Recessed Pendent /1 [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engin eyed to provide a minimum design density of 0.10 gpm /Rover the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3 /4" NPT thread. Water seal assembly shall consist of a Teflon- coated Belleville spring washer and machined cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155 °F (68 0 C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a 1 /2 " cover plate adjustment. Cover plate temperature rating shall be 135 °F (57 °C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). 11. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by O The Reliable Automatic Sprinkler Co., Inc. Relle ia bi (800) 431 -1588 Sales Offices Recycled (800) 848 -6051 Sales Fax ®Paper (914) 829 -2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 05/08 PM 9999970322 Ja 0 R I ble A Residential Flat Concealed Sprinkler engineered for a minimum design density of 0.05 gpm/ft with low GPM requirements. Features 1. Very low water flow requirements. 2. 'h" (13mm) Total adjustment. 3. Thread- On/Thread -Off or Push- On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258 -93 -E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- tial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30, RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler de- flector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprin- kler patterns. The combination of speed of operation and high dis- charge pattern required for residential sprinklers has dem- onstrated, in fire testing, an ability for controlling residen- tial fires, and thereby providing significant evacuation time for occupants. The RFC30, RFC43 and RFC49 Sprinklers provide the best form of fire protection by combining an attractive ap- pearance and Y2" (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing Bulletin 006 Rev. F Model RFC30 (SIN RA0611) Model RFC43 (SIN RA0612) Model RFC49 (SIN RA0616) Residential Flat Concealed Sprinklers the most dependable fire protection available, an automat- ic sprinkler system. The RFC30, RFC43 and RFC49 are UL Listed Residential Sprinklers to be installed in the residential portions of any occupancy in accordance with NFPA 13, 13R, & 13D. The RFC30, RFC43 and RFC49 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC30, RFC43 and RFC49, for residential installa- tions, use a 165 °F (74 °C) fusible solder link in a tuning fork style sprinkler frame with a drop -down deflector. This as- sembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135 °F (57 °C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler inside to 0 0 0 M T The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 ceiling temperature. The subsequent operation of the sol- der link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop -down deflector is properly located below the ceiling. The residential distri- bution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 /s inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler /cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler /cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART Temperature Rating OF THE SPRINKLER /CUP ASSEMBLY. MODEL RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135 °F RATED COVERS. Note: A leak tight Y2" NPT (R1/2) sprinkler joint can be ob- tained with a torque of 8 -18 ft -lbs (10,8 - 24,4 N -m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Cover assemblies provide up to 1 /2 " ( 13mm) of adjust- ment. Turn the cover clockwise until the flange is in con- tact with the ceiling. For the push -on /thread -off option, the cover assembly is pushed onto the cup and final adjust- ment is made by turning the cover clockwise until the skirt flange makes full contact with the ceiling. Cover removal requires turning in the counter - clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressur- ization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Sprinkler Cover Plate Max. Ambient Temp. 165 °F /74 °C 135 °F /57 °C I 100 °F /38 °C Installation Data: RFC30 (SIN RA0611) Thread K Factor Sprinkler Maximum Minimum Minimum Required Size K Factor Spacing Distance to Distance between Sprinkler Discharge Flow Press. inch (mm) '/2" (15mm) ft. (m) Wall s p rinklers 8(2.43) 12 (45) 7.8 (0.54) ft. (m) ft. (m) gpm (Lpm) psi (bar) '/2 (15mm) 3.0 12 x 12 (3.6x3.6) 6(1.83) 8(2.43) 9(34.1) 9.0 (0.62) 1 12" (15mm) 3.0 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 10 (37.8) 11 (0.76) Note: 1 bar = 100 Kpa Installation Data: RFC43 (SIN RA0612) Thread Size Inch (mm) K Factor Sprinkler Spacing ft. (m) Maximum Distance to Wall Minimum Distance between sprinklers Minimum Required Sprinkler Discharge Flow Press. ft (m) ft. (m) gpm (Lpm) psi (bar) '/2" (15mm) 4.3 12 x 12 (3.6x3.6) 6(1.83) 8(2.43) 12 (45) 7.8 (0.54) Y2" (15mm) 4.3 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13 (49) 9.1 (0.63) /2" (15mm) 4.3 16 x 16 (4.9x4.9) 8(2.43) 8(2.43) 13 (49) 9.1 (0.63) Y2" (15mm) 4.3 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 18 (68) 17.5(l.21) '/2 (15mm) 4.3 20 x 20 (6.0x6.0) 10 (3.05) 8(2.43) 21 (79) 23.8(l.64) Note: 1 bar = 100 Kpa Installation Data: RFC49 (RA0616) Thread Size inch (mm) K Factor Sprinkler Spacing ft. (m) Maximum Distance to Wall Minimum Distance between sprinklers Minimum Required Sprinkler Discharge Flow Press. ft. (m) ft. (m) gpm (Lpm) psi (bar) 1 12" (15mm) 4.9 12 x 12 (3.6x3.6) 6(1.83) 8(2.43) 13 (49) 7.0 (0.48) h" (15mm) 4.9 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13 (49) 7.0 (0.48) 12" (15mm) 4.9 16 x 16 (4.9x4.9) 8(2.43) 8(2.43) 13 (49) 7.0 (0.48) '/2 (15mm) 4.9 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 17 (64.3) 12.0 (0.83) 12" (15mm) 4.9 20 x 20 (6.0x6.0) 10 (3.05) 8(2.43) 20 (75.7) 16.7(l.14) Note: 1 bar = 100 Kpa FOR SLOPED CEILING APPLICATIONS SEE RASCO BULLETIN 035. 2. Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler cover plate assem- bly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. Model RFC30, RFC43 and RFC49 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential con- cealed sprinklers with drop -down deflector and adjust- able flat cover plate engineered for a minimum design density of 0.05 gpm /ftz. Sprinkler frame and deflector shall be of bronze frame construction having a' /2 NPT thread. Thermal element shall consist of an approved black - painted beryllium- nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon- coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K- factor shall be nominal 3.0 (44), 4.3 (62.4), and 4.91 (70) having a 5 /, ", 3 / 8 " and 7 /,6 " orifice. Temperature rating shall be Ordinary 165 °F (74 0 C); cover plate temperature rating to be 135 °F (57 0 C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allowing a' /2" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop -down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop -down sprinkler deflector from dam- age, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty - specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 (Bulletin 006), Model RFC43, SIN RA0612 (Bulletin 006) or Model RFC49, SIN RA0616 (Bulletin 006). Ordering Information Cover Plate Finishes M Specify: Standard Finishes 1. Sprinkler Model 2. Cover Plate Finish Chrome 3. Thread -On or White Push -On Feature Special Application 1" x 112" REDUCING TEE OR ELBOW L I r 92' [66.55mm) 2 " [58.42mm] DIA I HOLE IN CEILING CUP CEILING " [ 12.70 —] MAX. COVER ADJUSTMENr CC P COVER PLA rE ASSEMBLY 34" [84.21mml DIA. 2" [50.8-1 1 MAX. FACE OF FITTING rO FACE OF CEILING DIMENSION 1 J" [4.96, m] ooa rA COVER PLATE: 1 /2 " L12.7mml ADJUSTMEN Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome (1) Other colors and finishes avail- able. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warran- ties. 3. Reliable... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® Recycled Re'; (800) 431 -1588 Sales Offices Paper �� (800) 848 -6051 Sales Fax Revision lines indicate updated or new data. ' (914) 829 -2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A 02111 PM 9999970261