Loading...
HomeMy WebLinkAboutB06-0196 Revision 49 IR 11440 Bulletin 125HKS HILL GLAZIER STUDIO REVIEVNED By BULLETIN PROJECT: Four Seasons Resort at Vail Vail, Colorado OWNER: Black Diamond Resort— Vail, LLC Vail Development 09, LLC Barclays Capital Real Estate 200 Park Avenue New York, NY 10017 (212) 412 -1664 ARCHITECT: HKS Inc, Hill Glazier Studio 925 Alma Street Palo Alto, CA 94301 PROJECT #: 11247 / 02028 ARCHITECT'S BULLETIN #: 125 DATE OF ISSUANCE: 01/25110 Description: Item #1 — Ski Rental and Sales Office Revision Revised level 5 admin /retail area per owner's direction. See A2052 and A3052, revised door schedule, MCN #78, ECN #52, and revised lighting drawings and specs Item #2 — Mechanical Change Notice #78 Retail Area Revisions Item #3 — Mechanical Change Notice #79 Loading Dock Sequence of Operations Item #4 — Mechanical Site Instruction #91 Cooling Tower Freeze Protection Item #5 — Mechanical Site Instruction #92 Multi -Zone AHU Control Item #6 — Electrical Change Notice #52 Ski Boot Renovation Attachments: (List attached documents that support description) Architectural Drawings, dated 01/25/10, includes sheets A2052 and A3052. Door Schedule, 1 page, dated 1/25/10 Mechanical Change Notice #78, dated 12/29/09, includes sheets M2052 and M3052, all dated 01/20/10 Mechanical Change Notice #79, dated 1/18110, includes sheets M5221 and M2061, all dated 01/19/10 Mechanical Change Notice #91, dated 1/18/10, includes sheets M522, all dated 01/18/10 �► Mechanical Change Notice #92, dated 1/18/10, includes sheets M522, all dated 01/19/10 HKS RIEN, HILL GLAZIER STUDIO a Electrical Change Notice #52, dated 1/22/10, includes sheets E2.05.2.2 and E3.05.2, all dated 01/22/10 Lighting Drawings, LT5.3 and LTC5.3, dated 1/22/10 Dimming Specification, dated 1/22/10, 1 page End of Bulletin Lighting Equipment Schedule, dated 1/22/10, 11 pages Remote Control Station Schedule, dated 1/22/10, 11 pages Lighting Cut Sheet, type J, J.1, J.2 & J.3, 2 pages 1 HILL GLAZIER BULLETIN #125 A r c h i t e c t s Issue Date 1/25/10 SECTION 08001 - DOOR_�C ,EPIJEE J i Door Exterior / Door Door HDWR Closer HDWR FIN. OPENING SIZE DOOR FRAME Armor(A) / Mop(M) / No. Location Interior Ra' LEVEL 5 HGA Project Number 02028 yp see legend) Width Height T hick Mat'I Fin at'I Finish Kick(K) Plate Remarks PR 3'-6" PR 3'-6" P 3' -0" ' -0' T -6" PR 4' -0" T-6" ' -0" 7'- 3 7- " 3'-6" 7 T-0 7'-6" 3' -0 8'-0" T -6" 3' 7 - 3 - T -0" 7' -0" PR T -0" T -0" -0" T 9 1 -W 14' 29'-0 1 -3" PR 7- — 7-0" 3' -0" 7 - " T-0", 2' -0" 7'- T -0 - T -0' -0" 7' 2'-6" ' TV' 3 -0" — 7 r -o , , 7' -0" T -0" 7' -0" T-0' T -6" 3'-0" 7' -6" 3 -0 -6" 3 -0" -0" 3. 6 T -0" -0" 7-6 3 7' '-0 7- T T -0" S-0' -0" -0" 7'-0' 7'- 3'-0 7 -0 -6" =30 -. _. 7 = 6 . -0 7 3. 3-0 . , 7147 ' P _0 -0„ 7 PR 3' T- 6 - P R 3 -0" R T -0" 7' Four Seasons Resorts Vail, Colorado Page 9 of 24 �j� �rPI�7Le1� 0 "B B i�jL'� Four Seasons Resorts Vail, Colorado Page 9 of 24 1AXXX MMM GROUP Mr. John Curtis Hill Glazier Studio 1 Vail Road Vail, Colorado 81657 Project: Vail Colorado - Four Seasons Hotels and Resorts Medh.ahica C hifi §e Notice Mechanical Change Notice No. Revision: 78 Issue Date : Tuesday, December 29, 2009 Project Number. 1807286 -000 The follow ing items are proposed changes to the contract for this project. Unless noted below, work is not to proceed until authorized by a change order. All material and workmanship are to be described in the contract documents unless otherwise stated. Please submit an itemized quotation for changes to the contract value and /or to the project schedule. Title: Retail Area Revisions Reason for Change: OWNER This change is a result of Ownership's request to revise the 5th floor area formally housing the Logo Shop. Please note that the sprinkler layout will need to be revised to reflect the architectural changes. Refer to M2.05.2 for HVAC revisions. Refer to M3.05.2 for piping revisions. END OF MECHANICAL CHANGE NOTICE Adrian Duta MMM Group 11MI M Group Limited - Consulting Engineers 100 Commerce Valley Drive West, Thornhill, ON Canada L3T 0A1 Bus: 905 -882 -1100 Fax: 905-882-7282 Website: www.mmm.ca M ) Mecharcal • +ANXX MMM GROU P Change Notice Mr. John Curtis Hill Glazier Studio 1 Vail Road Vail, Colorado 81657 Mechanical Change Notice No. 79 Project: Vail Colorado - Four Seasons Hotels and Resorts Revision: Issue Date: Project Number: Monday, January 18, 2010 1807286 -000 The follow ing Revs are proposed changes to the contract for this project. Unless noted below, w ork is not to proceed until authorized by a change order. All material and w orknwship are to be descrbed in the contract documents unless otherwise stated. Please submt an itemized quotation for changes to the contract value and/or to the project schedule. Title: Loading Dock Sequence of Operations Reason for Change: This change is issued as a clarification of the intended sequence of operations for the loading dock exhaust system Refer to attached drawing M5.22.1 for the control sequence. Refer to attached drawing M2.06.1 for the floor plan. 4 Adrian Duta MMM Group MMM Group Limited - Consulting Engineers 100 Commerce Valley Drive West, Thornhill, ON Canada L3TOA1 Bus:905 -882 -1100 Fax: 905 -882 -7282 Website: w w w .mrm.ca Medical A#AXXX MMMGROUP V Site Instru #ion Mr. John Curtis Site Instruction No: 91 Hill Glazier Studio 1 Vail Road Issue Date: Monday, January 18, 2010 Vail, Colorado 81657 Project 1807286.000 Project: Vail Colorado - Four Seasons Hotels and Resorts Site instructions are issued only for the purpose of recording any clarification or interpretation of the contract document or giving direction on problems resulting from field conditions. These instructions are subject to the provisions of the contract and w tl not affect the contract. Should the Contractor require a change in the contract price or time, he shall advise the Architect w ithin seven days of receipt of this instruction. Cooling Tower Freeze Protection This instruction is issued as a clarification of the control sequence for the cooling tower during free cooling mode. Refer to attached drawing M5.22 for details. , 4 — Adrian Dula MMM Group cc: Inspection - M M Group MM Group - Consulting Engineers 100 Commerce Valley Drive West, Thornhill 0nL3T0A1 Bus: 905 -882 -1100 Fax: 905 -882 -7282 uVrwchlasgrs11shn Mechanical MANN& MMM GROUP Site Instruction Mr. John Curtis Site Instruction No: gQ 3 Hill Glazier Studio 1 Vail Road Issue Date: Monday, January 18, 2010 Vail, Colorado 81657 Project 1807286 -000 Project: Vail Colorado - Four Seasons Hotels and Resorts Site Instructions are issued only for the purpose of recording any clarltication or interpretation of the contract document or giving direction on problens resulting from field conditions. These instructions are subject to the provisions of the contract and will not affect the contract. ShoWd the Contractor require a change in the contract price or time, he shall advise the Architect w Rhin seven days of receipt of this instruction. Multi Zone AHU Control This instruction is issued in response to RFI -2871 to clarify the control diagram with regards to the multizone air handling units Installed on site. Please refer to attached drawing M5.22 for details. 0 Adrian Duta MMM Group cc: Inspection - MMM Group MMM Group - Consulting Engineers 100 Commerce Valley Drive West, Thornhill OnL3T OA1 Bus: 905- 882 -1100 Fax: 905 -882 -7282 txVreW2rsgmsi1.sfm I`\` MMM GROUP John Curtis HKS Hill Glazier Studio 1 Vail Road Vail Colorado 81657 970 - 476 -7849 Project: VAIL COLORADO - Four Seasons Hotels & Resorts 1 Vail Rd, Vail CO Electrical Change Notice Electrical Change Notice No. Revision: Issue Date Project Number. 52 Friday, January 22, 2010 1807286 -000 The following items are proposed changes to the contract for this project. Unless noted below, work is not to proceed until authorized by a change order. All material and workmanship are to be described in the contract documents unless otherwise stated. Please submit an itemized quotation for changes to the contract value and/or to the project schedule. Title: Ski Boot Renovation Reason for Change: The purpose of this change is to revise the Logo Shop Area 546 on Level 5 to suit the new requirements. 1.0 General 1.1. Delete existing luminaires, power outlets and system outlets from area defined in attached sketches. 2.0 Level 5, Area 2 Area Plan Power & Signal - Dwg. E2.05.2 (Not Re- issued) 2.1. Revise power and systems in Logo Shop area and surrounding rooms as per attached sketch SKE- 2.05.2.2. 1.0 Level 5, Area 2 Area Plan Lighting/Reflected Ceiling - Dwg. E3.05.2 (Not Re-fssued) 2.2. Revise lighting in Logo Shop area and surrounding rooms as per attached sketch SKE- 3.05.2.1. End of ECN #52 cc: Inspection - Rybka Smith & Ginsler Limited Rybka, Smith & Ginsler Limited - Consulting Engineers 18 Champlain Boulevard, Toronto, Ontario M3H 2Z1 Bus: 416 - 398 -6020 Fax: 416 - 398 -6361 Night Line: 416- 398 -6090 E -mail: info @rybka.com Website: www.rybka.com P5849iww . ..... - U jT -80 - CONFERENCE 1 1 �5650 I U -S2-16 ------------ ] I. 1 j!P5B 56F I n' -T 11"51349 . ..... .... . ARRIVAL p ..... - --- --- . ....... .. ........ i 1345 AGM R5 • -01 fcu�' i P51351 D A - ER' R�.849.1 --- i.-j .-I it .1- . . ............. - - --- - -- ---- ...... .... 4 - -- - --------- 547' Yom ........ . ..... .. . . .......... . .AD L . . ....... .. - ----- --------- 1 4 01 CL 7 . ....... . ... ..... K P5E P,5 11; REQUEST FRS SALES 6 �---OFFICE— ib FRji F -U HELP 9 .... ..... . .. ...... ..... ........ P51J25 __ _. - 546A 5B CLOSET 41 !P51342 PM JPS2 14 546D PS MF 842 HE 25 SKL )T 1 FITTING RE", L/" 546B E5 6-g 51341 P P5 32 AL .... . ...... . ...... ....... ... ......... ... . . ... ............ MV i 545 1447 SO READ THIS DWG, IN CONJUNCTION WITH DRAWING #E- JOB FOUR SEASON - VAIL, COLORADO Scale Date JAN. 22.10 A AM& DRAWING TITLE LEVEL-05, AREA-2, Drawn TG MMM GROUP AREA PLAN, BY "Ill I IM-1., Lioni..l POWER & SIGNAL - SKI BOOT RENOVATION Checked TG Consul Lin Engl... re By "11-11*i Job Toronto, Ontario, M3H 221 Number 1807286005 Telephone: 416-398,6020 Drawing INumber I SKE-2,052.2 Q, 5 D D SALES I I - FFICE�, i 546 . 504 C A.I I ' I � GI .._.. - gt ._ _ 11 9 L' A. i _. HIGH LEVEL _. l ' GALLERY 545 E21.2 * P -- :. P - -� - - - �Y Z46 C C % E46: 4 (2)A.4 E24 (4 A.4 (2)A.4 e READ THIS DWG. IN CONJUNCTION WITH DRAWING #E- Q JOB FOUR SEASON - VAIL, COLORADO Scale '"` Date JAN. 22.10 Drawn DRAWING TITLE LEVEL -05, AREA -2, TG MMM GROUP AREA PLAN, Rgbes. 6-1th & oils]- United LIGHTINGAEFLECTED CEILING - SKI BOOT RENOVATION Checked By TG C"su l ting Enginasrs is C —'pl.m aeo]e.erd. Toronto. 0-1i. M3H 2Z7 Job Number 1807286005 T el c c n on e: 416.398 -6020 Drawing Number SKE- 3.05.2.1 0: \07 \180728600 \Electr1cal \plots \E3.05.2.dwg January 22, 2oio Bulletin #225 ` t ' Four Seasons Vail — Vail Colorado DIMMING SPECIFICATION: Lutron Grafik 7000 Zone Dimming VA Load Auxiliary Number Channel Load Type Description Equipment Ski Shop Lutron Grafik Eye (2) GRX - 3504 -A -WH SS1 1 2020 INC /LV Linear Wallwasher (b) SS2 2 400 INC /LV Downlight (a) SS3 3 225 INC /LV Desk Accent SS4 4 125 INC /LV Art Accent (a) SS5 5 goo INC /LV Wall Washer (a)(b) SS6 6 300 INC /LV Under shelves light (a) SS7 Spare SS8 Spare Sales Office SO1 1 300 INC /LV Pendant 502 2 125 INC /LV Art Accent (a) SO3 3 188 INC /LV Art Accent (a) SO4 4 375 INC /LV Display Case Accent SOS 5 125 INC /LV Desk Accent SO6 6 100 INC /LV Wallwasher SO7 7 200 INC /LV Desk Accent SO8 8 400 INC /LV Wall sconces SOg g 500 INC /LV Down Light (a) Auxiliary Equipment (a) Provide Lutron Toroidal Choke sized as close to the load as possible or next higher size -load not to exceed l000 watts (b) Zone requires Lutron Power Booster, NGRX -PB -WH (c) Normal /Emergency Circuit (d) Zone requires Lutron Fluorescent Interface GRX - FDBI -16A -120 (e) Zone requires GFCI Breaker Load Type Abbreviations INC/LV = Incandescent: Magnetic Low Voltage ELV = Electronic Low Voltage NCC = Neon /Cold Cathode ND = Non -Dim FDB = Fluorescent Dimming Ballast LED = Light Emitting IOD January 22, 2010 — Bulletin #125 Four Seasons Vail — Vail, Colorado LIGHTING EQUIPMENT SCHEDULE Type Description A Recessed Low Voltage PAR 36 Adj ustable Fixture Champagne Cone 41/8" Aperture A.1 Recessed Low Voltage Adjustable Fixture AR1ii Version Champagne Cone 41/8 " Aperture A.2 Recessed Low Voltage Adjustable Fixture A11=1 Version Champagne Cone 41/8 " Aperture A.3 Recessed Low Voltage Adjustable Fixture ARiii Version Champagne Cone 41/8 " Aperture A.4 Recessed Low Voltage PAR :t6 Adjustable Fixture Champagne Cone 41/8" Aperture A.5 Deleted B Recessed Par 3o Downlight Champagne Cone 5" Aperture Manufacturer No. Lama Kurt Versen GE SoPAR36/VNSP K7411 -BG Voltage 120/12 Kurt Versen Phillips 120 /12 K7422 -BG ALU111MM- 75W- G53- 12V -8D Kurt Versen Osram Sylvania SoAR111 /4° 120 112 K7411 -13G Kurt Versen Phillips 12042 K7412 -BG ALU111MM-75W-GS3-12V- 24D Kurt Versen GE 5oPAR36 /NSP 120/12 K7411 -BG Kurt Versen C7327 -BG GE 7SPAR3o /H /FL25° 120 Page 2 January 22, 2010 Four Seasons Vail — Colorado LIGHTING EQUIPMENT SCHEDULE Type Description Manufacturer Lamp Voltage C Recessed Lensed Wallwasher Kurt Versen GE iooPAR38 /HIR /FL40 120 Champagne Cone E7528 -BG 5 7/8" Aperture D Recessed Small Aperture A -Lama Kurt Versen GE ioo /goW 120 Downlight C7319-BG Champagne Cone 41/8" Aperture E Low Voltage Recessed Downlight Kurt Versen GE Q5oMR16 /C /N5Pi5O 120/12 Champagne Cone K7301 -BG (EXT) 41/8" Aperture F Low Voltage Recessed Kurt Versen GE Q5oMR16 /C /NSP15 120/12 Adjustable Downlight K7430 -BG (EXT) Champagne Cone 41/8" Aperture G Deleted G.1 Recessed Lensed Wallwasher Kurt Versen GE 50PAR2o/H /NFL25° 120 Champagne Cone E7S26 -BG 41/8" Aperture G.2 Recessed Lensed Wallwasher Kurt Versen Philips 120 Champagne Cone WE526 5oPAR2o /HAL /SPL /NFL3o° 41/8" Aperture Brass base required Wet Locations H Recessed Small Aperture Par 20 Kurt Versen GE 5oPAR2o /H /NFL25° 120 Downlight (Front of House) C73oo -BG -MOD 4" Aperture Modified for 6" Depth Modified for 6" Depth H.1 Recessed Small Aperture Par 20 Kurt Versen GE 5oPAR2o /H /NFL25° 120 Downlight C73oo -BG Champagne Cone 41/8" Aperture I Not Used J Recessed Small Aperture A -Lama Kurt Versen GE loo /goW 120 Downlight C7322 -BG 5" Aperture Gold Trim Page 3 January 22, 2010 Four Seasons Vail — Colorado LIGHTING EQUIPMENT SCHEDULE Type Description Manufacturer Lama Voltasm 11 Recessed Small Aperture A -Lamp Kurt Versen GE ioo /goW 120 Double - Wallwasher E7522 -BG -D (Front of House) Double Wallwasher 5" Aperture Gold Trim J.2 Recessed Small Aperture A -Lamp Kurt Versen GE ioo /goW 120 Downlighht- Wallwasher E7522 -13G- Wallwasher 1.3 Recessed Small Aperture A -Lamp Kurt Versen GE ioo /goW 120 Downlight- Wallwasher E7522 -BG -C _5 Aperture Gold Trim Corner Wallwasher K.1 Linear Incandescent Strip Alexandra & Co. 3 Watt Incandescent Frosted 120/24 With Festoon Sockets (a) IllumiLite 2 1/4" O.C. Series 78 Remote magnetic transformers 78- XX- AF- B- U -T2 -G required. Refer to manufacturer's chart for recommended wire size. Lengths to be field verified. Contractor is responsible for ordering the necessary T2 terminals on the second end of the strip. Strips must be ordered from the factory with terminal connectors on both ends of the light strip to make tandem connecting possible. Contractor to provide 10% overage of spare lamps. K.2 Linear Incandescent Strip Alexandra & Co. 5 Watt Incandescent Frosted 120124 With Festoon Sockets (a) IllumiLite 21/4" O.C. Series 78 Remote magnetic transformers 78- XX- AG- B- U -T2 -G required. Refer to manufacturer's chart for recommended wire size. Lengths to be field verified. Contractor is responsible for ordering the necessary T2 terminals on the second end of the strip. Strips must be ordered from the factory with terminal connectors on both ends of the light strip to make tandem connecting possible. Contractor to provide 10% overage of spare lamps. January 22, 2010 Four Seasons Vail — Colorado LIGHTING EQUIPMENT SCHEDULE Type Description Manufacturer K.3 Linear Incandescent Strip Alexandra Lighting Co. With Festoon Sockets (7a IllumiLite 21/4"0 Series 78 Remote magnetic transformers 78- XX- AG- B- U -T2 -G required. Refer to manufacturer's chart for recommended wire size. Lengths to be field verified. Contractor is responsible for ordering the necessary T2 terminals on the second end of the strip. Strips must be ordered from the factory with terminal connectors on both ends of the light strip to make tandem connecting possible. Contractor to provide lo% overage of spare lamps. L DELETED L.1 DELETED M DELETED N Picture Light -XXX Length Alexandra Lighting Co. S Watt Picture Light Series 794 Lamps 4" o.c. 794 -PB- XX -X -X -X Specify Projection Unlacquered Polished Length and projection to be determined Brass after art is selected O Not Used P Recessed A -Lamp Downlight Kurt Verse Champagne Cone C7321 -BG 5 7/8" Aperture Q Recessed Low Voltage Double Lensed Amerlux Linear Wallwasher LW WCDR- 35 -MR16- Drywall R EMOTE -M W- 120 -XX Lamps 6" o.c. Finish Color TBD Contractor responsible for verifying exact length per field measurements Page 4 Lamp Voltage io Watt Incandescent Frosted 120/24 SWT3 GE 15oA/W Soft White GE Q35MR36 /C /SP20° (FRA) 120/12 120 120/12 Page 5 January 22, 202.0 Four Seasons Vail - Colorado LIGHTING EQUIPMENT SCHEDULE tae Description Manufacturer Lamp Voltage R Recessed Low Voltage Small Aperture Sylvan Alesco GE 25R14SC /SP 120/12 Downlight A8600TB- ALR1425 Included Remote transformer required Contractor to provide shop drawings showing transformer layout and sizes S Low Voltage Linear Lighting for Roberts Step -Lite Lamps included 120/12 Banquets and for Mirrors at Spa RA -12 Series Remote Transformer Required RA- 12- EB -CL -XX Lengths to be field verified S.1 Linear LED Night Light Roberts Step -Lite Lamps included 120/12 12 Vdc drive required RW12- LED -285oK T Recessed T -4 Downlight in Ballroom Kurt Versen GE 25oT -4 /Frosted 120 Champagne Trim C7394 -BG 7 1 /4" Aperture U.1 Surface Mounted 2 ft. Incandescent Alkco Supplied with fixture 120/12 Strip Fixture HG23 /10 /SGD V Recessed Floor Column Uplights (al BK Lighting GE Q5oMR16 /C /NSP15° (EXT) 120/12 Living Room MR16 Recessed Fixture 4 -5/8" Diameter CUS- 1403 -22 Finish to match floor W iW Profile G2- Narrow Beam LED Color Kinetics LED Included 120/24 Fixture to supply the following 15 W /FT. Contractor to field measure for exact pieces of equipment length. 1o° x 11o° Beam Angle (a) Aux Box 103 - 000021 -01 (b) Mayer 3 103 - 000019 -00 (c) iW PDS -15o 509 - 000001 -00 (d) iW Profile G2 Narrow Beam _ 501 - 000010 -01 W.1 Linear LED in Handrail Alexandra Co. Lamps included . µ io /x2 12W per Linear Feet 24L- XX- C -6 -12- Voltage 120 120 120 220 120/12 120/12 120/12 120 120 120/12 120/12 Page 6 January 22, 2010 Four Seasons Vail — Colorado LIGHTING EQUIPMENT SCHEDULE Type Description Manufacturer Lamp W2- 1/2- P2 -D -1 X Cold Cathode Neotek, Inc. 12oma (High Power Factor) 817.640.4300 Incandescent White 2400K, 25mm (6 Watts per Linear ft.) Y.3 Surface Mounted 3 ft. Fluorescent Strip Columbia GE Fixture CN- 3 -1 -39 -EB5 -120 F39W/T5 / /HO Y.4 Surface Mounted 4ft. Fluorescent Columbia GE Strip Fixture CN- 4 -1 -54- EB5 -120 F54W/T5 /83o /HO Z Porcelain Socket Keyless Leviton GE 15oA /W AA MR16 Exterior Monopoint Wall B -K Lighting GE Q5oMR16 /C /NFL25 Mounted Grazer Night Star II (EXZ) NSI I -7- BZP -13 With Canopy BC6 -BZP BB Exterior Step Light B -K Lighting GE Q5oMR16 /C /NSP15 Must be mounted a minimum of 12" Step Star (EXT) above tred. SS -6 -BZP -A Remote transformer required. CC Exterior Recessed Ground Uplight B -K Lighting GE Q5oMR16 /C /NSP15 Remote transformer required B- HP2- MR -RS -6 -BZP -CPC (EXT) (no honeycomb baffle) DD Surface Horizontal- mounted Closet Lightolier (2) GE 6oA19/W Light Opalux 6 34 8 EE Recessed Spa Corridor Foot Lights 10 Lighting LED o- o1- SL- A- 3K- 100 -2 -0 FF Recessed Wet Location Spa Shower BEGA 2oWG4 Lights 1121 Included GG Recessed Low Voltage Double Lensed Amerlux GE 035MR16 /C /SP20° Linear Wall Grazer LWGCDR- 35 -MR16- (FRA) Lamps Space 6 "o.c. Remote -MW- 120 -XX -WET WET location Finish Color TBD Contractor responsible for verifying exact length per field measurements Voltage 120 120 120 220 120/12 120/12 120/12 120 120 120/12 120/12 KK LL MM NN 00 PP QQ Deleted Wall Mounted Path Light Bega Page 7 January 22, 2010 Tree Mounted Downlight BK Lighting Four Seasons Vail — Colorado Delta Star LIGHTING EQUIPMENT SCHEDULE Tree Strap Type Description Manufacturer Lamp GG.1 Recessed Low Voltage Double Lensed Amerlux GE 035MR16 /C /SP20° Linear Wall Grazer LWGCDR- 35 -MR16- (FRA) Lamps Space 6" o.c. Remote -MW- 120 -XX A- CUS36 -B -BZP Finish Color TBD Contractor responsible for verifying exact length per field measurements HH Exterior Fountain Light Hydrel 1ooQ LAMP INCLUDED Contractor to determine conduit entries 44:L3 -1000- 120- FLC -NM- and cord length. XX- XX -LPI II Not Used JJ Entry Pole Neri Pole 1ooMH Lamp to be horizontal mounted 8016.00 Neri Lantern ARCO LA500 KK LL MM NN 00 PP QQ Deleted Wall Mounted Path Light Bega Black Finish 2295 -P Tree Mounted Downlight BK Lighting Delta Star DS -8- BZP -9 -A with Tree Strap TS- MB- Z- BZP -XX Tree Mounted Uplight with Adjustable BK Lighting Power Pie up to 36" Delta Star DS -7- BZP -9 -A with adjustable power pipe PP- A- CUS36 -B -BZP Not Used Emergency Path Light NOT USED 27 Watt CF Twin 4 -P Osram /Sylvania #FT24 DL /83o /ECO GE Q5oMR16 /C /FL40° (EXN) GEQ50MR16 /25° FX Luminaire 20 Watt Demilite DL- 2o- 18R -BZ Xenon Voltage 120/12 120 120 277 120/12 120/12 120/12 Voltage 120/12 120/12 120 120 120/12 120/12 120/12 120 Page 8 January 22, 2010 Four Seasons Vail — Colorado LIGHTING EQUIPMENT SCHEDULE Type Description Manufacturer Lamp RR Recessed Hydrel GE Q5oMR16 /C /NSPi5* Wet Location 4800- SQ- B- M75- 12 -FL- (EXT) Whirlpool Fixture CLC- NM- 3445B-RG- ? ? ? -LP SS Surface Mounted BK Lighting GE QSoMR16 /C /NFL25° Monopoint Fixture DS- 7- BZP -9 -B (EXZ) with BC4 -BZP TT Recessed Niche Mount Wet Location Hydrel 2000 Watt PAR64 Lamp Pool Fixture 4427- B- P6410001- 12o -NSP- Included Bronze Finish CLC-NM-34B-RG-CSLXX- With Rock Guard LPI Contract responsible for verifying length of cord (CSLXX) UU Bollard Louis Poulsen BYS411ooW /H PS/ED Medium /120/ COR -TEN V V Deleted WW Deleted XX Vail US Long Life HPSiooEi7 Citypole TOVSS9644PH City to Select YY Retail Recessed Belfer Virtual Axis GE Multi -Point Fixture io' 161- XX- BP- HP- I -DT -WH Q5oMR16 /HIR /CG10 YY.1 Retail Recessed Belfer Virtual Axis GE Multi -Point Fixture S' 161 -XX BP HP -1 DT -WH QS0MR16 /HIR /CG10 YY_z Retail Recessed Belfer Virtual Axis GE Multi -Point Fixture 4' 161- XX- BP- HP- I -DT -WH 05oMR16 /HIR /CG10 ZZ Wallmount Door Exit Light BK Lighting GE Q37MR16 /C /CG40 El Capitan EC -5- BZP -9 -B AAA Deleted AAA.1 Deleted BBB Deleted Voltage 120/12 120/12 120 120 120/12 120/12 120/12 120 January 22, 2010 Four Seasons Vail — Colorado Page g LIGHTING EQUIPMENT SCHEDULE ape Description Manufacturer Lama Voltage CCC Deleted DDD Deleted EEE Deleted FFF Deleted GGG Deleted GGG.i Deleted HHH Recessed Step Light Belfer Lighting 3.75 Watt 120/ Must be mounted a minimum of 12" 331oFP- XX- R -31 -24 Lamp Included 24 above tread iii Surface Mounted Quartz Uplight White Belfer Lighting GE (2)Qioo /DC /Frosted 220 723o -WH KKK Surface Mounted 4' -0" Linear Cove Focal Point GE F32T8 /SP3o /ECO 120 Light with T8 Lamp FCVA-26-iT8-iC-120-D- Lutron Dimmable Ballast Required CV -HW -4' KKK.1 Surface Mounted 3' -0" Linear Cove Focal Point GE F25T8 /SP3o /ECO 3.20 Light with T8 Lamp FCVA-26-iT8-2C- 220 -D- Lutron Dimmable Ballast Required CV -HW -3' LLL Surface Mounted z' -o" Linear Ts Bartco Lighting Sylvania FPi4 /830 120 Fluorescent Fixture BFL -1 4 Remote Ballast Required MMM Surface Mounted - A' -o" Linear TS Bartco Lighting Sylvania FP21 /830 120 Fluorescent fixture in the display case BF- CH- 21 -X -XX at Logo Shop Remote Ballast Required Electrical Contractor to verify length of cable and feed location prior to ordering NNN Recessed PAR 18 Wall Washer Kurt Versen GE 12oPAR /H /FL30 120 5 7/8" Aperture E7528 -BG 000 Not Used PPP Not Used January 22, 2010 Four Seasons Vail — Colorado LIGHTING EQUIPMENT SCHEDULE Page io Type Description Manufacturer Lamp QQQ Recessed in wall LED Floor Washlight Erco Lighting Blue LED CARLON FLOORBOX 337 w /Silver finish Per Manufacture's spec LWR Dimmable Duplex Wall Receptacle and Lutron (Receptacle) 33858.023— Control Gear NTR-1s- DFDU -BR- CPW0441 33 - Housing Lutron (Receptacle) RRR Recessed Small Aperture A -Lamp Kurt Versen GE loo /9oW Wallwasher E7519 -BG RP- FDU -10 -COLOR Champagne Cone 41/8" Aperture SSS PAR20 Cove medium base Belfer Lighting Philips incandescent extrusion 2502- 12- S -F -xx 5oPAR2o /HAL /SPL /NFL30 Straight With linera spread lens Brass bass required_ Sockets at 12" O.0 (part# LP2052) for each Contractor to filed measure for exact lamp length LFR Dimmable Duplex Floor Receptacle Lutron (Receptacle) and Plug NTR-I5- DFDU -GR- Contractorto hold plugs and install CPW0441 on all lamps during installation Lutron (Receptacle) NTR-2o- DFDU -GR- CPW0442 Lutron (Plug) RP- FDU -10 -COLOR Voltage 120/30 120 120 CARLON FLOORBOX P/N E976RFB CARLON ACTIVATION KIT P/N E97AK2 CARLON FLOORBOX E976RFB LWR Dimmable Duplex Wall Receptacle and Lutron (Receptacle) Plus NTR-1s- DFDU -BR- CPW0441 Contractor to hold plugs and install on all Lutron (Receptacle) lamps during installation NTR-2o- DFDU -BR- CPW0442 Lutron (Plug) RP- FDU -10 -COLOR Voltage 120/30 120 120 Page ii January 22, 2010 Four Seasons Vail — Colorado LIGHTING EQUIPMENT SCHEDULE Type Description Manufacturer Lamp Voltage Note #i: Lighting consultant, Bouyea & Associates, will travel to the jobsite and supervise final adjustments (aiming) to all adjustable light fixtures. The electrical subcontractor shall provide six (6) electricians to work with the lighting consultant for a period of four (4) days. Most of this work will occur after sundown (plan: 7pm -3am). The contractor should also be prepared to supply ladders and manlifts to reach the recessed fixtures. Note #2: Electrical subcontractor to hold an allowance of $2,000.00 US dollars to supply additional lamps for fixtures to be used in the focusing of lighting phase of the project. The lighting consultant, Bouyea & Associates, will supply a list of lamps to be purchased within 4 -6 weeks of their trip to the jobsite to focus the lighting. Contractorto receive these lamps and store them at thejobsite. The unused portion of lamps is then to be turned over to the hotel as attic stock. BULLETIN IM0 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description Controlled TBD G7- AR- W000 -0 -120 Grafik 7000 Central Processor TBD PJ62- ADPT -1 Jack Adaptor TBD NTOMX- 62J -WH TBD OMX -RS232 Touch Screen Interface TBD (3) OMX -AV LV Contact Closure Interface TBD GR6HHP Hand Held Programmer r1 Electrical Room G -502 NTOMX - HHPJ -WH All (By Residence Club Hand Held Program Jack Lobby) White Finish r2 Stair 'U' NTOMX - HHPJ -WH All S -519 Hand Held Program Jack (By Lobby Bar) White Finish r3 Concierge Vestibule NTOMX - HHPJ -WH All R -3 Hand Held Program Jack White Finish r4 SKI /Golf Bag NTOMX - HHPJ -WH All Storage Hand Held Program Jack Room 513 White Finish January 22, 2010 BULLETIN #125 Page 2 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description Controlled r5 Maid's Room NTOMX - HHPJ -WH All G -519 Hand Held Program Jack (By Exterior) White Finish r6 Valet Room NTOMX - HHPJ -WH All 534 Hand Held Program Jack White Finish r7 Service Station NTOMX - HHPJ -WH All 352 Hand Held Program Jack White Finish r8 Door Check NTOMX - HHPJ -WH All 355A Hand Held Program Jack White Finish r9 Coat Check NTOMX- HHPJ -WH All 372 Hand Held Program Jack White Finish r10 Wall Niche NTOMX - HHPJ -WH All Meeting Room 1 Hand Held Program Jack White Finish r11 Wall Niche NTOMX - HHPJ -WH All Meeting Room 2 Hand Held Program Jack White Finish r12 Vestibule NTOMX - HHPJ -WH All 373 Hand Held Program Jack White Finish **Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. January 22, 2010 BULLETIN #125 Page 3 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description Controlled r13 Vestibule NTOMX - HHPJ -WH All 375 Hand Held Program Jack White Finish r14 Hallway NTOMX - HHPJ -WH All 305 Hand Held Program Jack White Finish r15 Hallway NTOMX- HHPJ -WH All 305 Hand Held Program Jack White Finish r16 Janitor's Closet NTOMX - HHPJ -WH All 389 Hand Held Program Jack White Finish r17 Boardroom NTOMX - HHPJ -WH All 378 (To be mounted Hand Held Program Jack In base cabinet) White Finish r18 Electrician's Room NTOMX - HHPJ -WH All 218 Hand Held Program Jack White Finish r19 Office NTOMX - HHPJ -WH All 234 Hand Held Program Jack White Finish r20 Storage NTOMX - HHPJ -WH All 233 Hand Held Program Jack White Finish "Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. January 22, 2010 BULLETIN #125 Page 4 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description Controlled r21 Spa Administration NTOMX - HHPJ -WH All 242 Hand Held Program Jack White Finish r22 Mechanical Room NTOMX - HHPJ -WH All 265 Hand Held Program Jack White Finish r23 Janitor's Closet NTOMX - HHPJ -WH All 253 Hand Held Program Jack White Finish r24 Vestibule NTOMX - HHPJ -WH All 275A Hand Held Program Jack White Finish r25 Prep Room NTOMX - HHPJ -WH All 285 Hand Held Program Jack White Finish r26 Janitor's Closet NTOMX - HHPJ -WH All 269 Hand Held Program Jack White Finish r27 ** Vestibule NTOMX-KS-CF-XX-CPN3254 E1 -E55 538 NTOMX- 4S- NRL -XX LL1 -LL8 Key Control Station with LB1 -LB11 4 Scenes, Off 1-1 -1-9.4 Two -gang Faceplate: NT- T21T13- FB -XX -E * *Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. - * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. January 22, 2010 BULLETIN #125 Page 5 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description Controlled r28 ** Stair'U' NTOMX-KS-CF-XX- CPN3254 E1 -E55 S -519 NTOMX -4S- NRL -XX LL1 -LL8 Key Control Station with LBl -LB11 4 Scenes, Off 1-1 -1-9.4 Two -gang Faceplate: NT- T21T13- FB -XX -E r29 ** Electrical Closet NTOMX- KS- CF -XX- CPN3254 RL1 -RL10 G -502 NTOMX -4S- NRL -XX Key Control Station with 4 Scenes, Off Two -gang Faceplate: NT -T21 T13- FB -XX -E r30 ** Service Station NTOMX- KS- CF -XX- CPN3254 R1 -R14 352 NTOMX -4S- NRL -XX PD1 -PD5 Key Control Station with 4 Scenes, Off Two -gang Faceplate: NT-T21 T1 3-FB-XX-E r31 ** Janitor's Closet NTOMX- KS- CF -XX- CPN3254 E1 -E54 363 NTOMX4S- NRL -XX MP1 -MP7 Key Control Station with BQP1 -BQP5 4 Scenes, Off BP1 -BP12 Two -gang Faceplate: NT- T21T13- FB -XX -E r32 ** Hallway NTOMX- KS- CF -XX- CPN3254 BQP1 -BQP5 C -305 NTOMX -4S- NRL -XX BPI-BP12 Key Control Station with E1 -E54 4 Scenes, Off MP1 -MP7 Two -gang Faceplate: NT- T2lT13- FB -XX -E * *Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. January 22, 2010 BULLETIN #125 Page 6 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDU Control Zones Station Location Description Controlled r33 ** Janitor's Closet NTOMX- KS- CF -XX- CPN3254 ML1 -ML22 253 NTOMX -4S- NRL -XX WL1 -WL16 Key Control Station with 4 Scenes, Off Two -gang Faceplate: NT- T21T13- FB -XX -E r34 ** Vestibule NTOMX- KS- CF -XX- CPN3254 TC1 -TC7 275A NTOMX -4S- NRL -XX TR1 -TR12 Key Control Station with 4 Scenes, Off Two -gang Faceplate: NT- T21T13- FB -XX -E r35 ** Electrical Room NTOMX- KS- CF -XX- CPN3254 E1 -E54 218 NTOMX -4S- NRL -XX SR1 -SR8 Key Control Station with Y1 -Y6 4 Scenes, Off KC1 — KC6 Two -gang C1 -05 Faceplate: NT- T21T13- FB -XX -E r36 Hallway OMX- RACP- 1A -XX -E Partition Control C -305 Area Partition Control BA1 -BA6.2 Engraved BB1 -BB5.8 Requires Lutron Backbox r37 BALLROOM OMX- 5C- DW- XX- CPN2174 M1 -1 4 Scene, Off Preset Station BP1 -BP12 Engraved` * *Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. January 22, 2010 BULLETIN #125 Page 7 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description Controlled r38 Vestibule OMX- RACP- 1A -XX -E Partition Control Area Partition Control BQA1- BQA5.4 Engraved BQB1- BQB5.4 Requires Lutron Backbox r39 Meeting Room 1 OMX- 5C- DW- XX- CPN2174 M1 -1 4 Scene, Off Preset Station M1 -5 Engraved r40 Meeting Room 1 OMX- 5C- DW- XX- CPN2174 M1 -1 4 Scene, Off Preset Station M1 -5 Engraved r41 Meeting Room 2 OMX- 5C- DW- XX- CPN2174 M2 -1 4 Scene, Off Preset Station M2 -5 Engraved r42 Meeting Room 2 OMX- 5C- DW- XX- CPN2174 M2 -1 4 Scene, Off Preset Station M2 -5 Engraved r43 Banquet Room A OMX- 5C- DW- XX- CPN2174 BQA1- BQA5.4 4 Scene, Off Preset Station Engraved r44 Banquet Room A OMX- 5C- DW- XX- CPN2174 BQA1- BQA5.4 4 Scene, Off Preset Station Engraved r45 Banquet Room B OMX- 5C- DW- XX- CPN2174 BQB1- BQB5.4 4 Scene, Off Preset Station Engraved r46 Banquet Room B OMX- 5C- DW- XX- CPN2174 BQB1- BQB5.4 4 Scene, Off Preset Station Engraved "Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is' reactivated. - * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. January 22, 2010 BULLETIN #125 Page 8 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description Controlled r47 Ball Room A OMX- 5C- DW- XX- CPN2174 BA1 -BA6.2 4 Scene, Off Preset Station Engraved r48 Ball Room A OMX- 5C- DW- XX- CPN2174 BA1 -BA6.2 4 Scene, Off Preset Station Engraved r49 Ball Room B OMX- 5C- DW- XX- CPN2174 BB1 -BB5.8 4 Scene, Off Preset Station Engraved r50 Ball Room B OMX- 5C- DW- XX- CPN2174 BB1 -BB5.8 4 Scene, Off Preset Station Engraved r51 Private Dining OMX- 5C- DW- XX- CPN2174 PD1 -PD5.2 4 Scene, Off Preset Station Engraved r52 Spa Reception OMX- 5C- DW- XX- CPN2174 SR1 -SR8 4 Scene, Off Preset Station Engraved r53 Salon OMX- 5C- DW- XX- CPN2174 S1 -S8 4 Scene, Off Preset Station Engraved r54 Storage 233 OMX- 5C- DW- XX- CPN2174 FC1 -FC5 4 Scene, Off Preset Station Engraved "Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. January 22, 2010 BULLETIN #125 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Station Location r55 Fire Command r56 Wall Niche Meeting Room 1 r57 Wall Niche Meeting Room 2 r58 Banquet Room A r59 Banquet Room B Page 9 Zones Description Controlled OMX- 5C- DW- XX- CPN2174 EX1 -EX27 4 Scene, Off Preset Station ST1 -ST4 Engraved T1 -T2 OMXSL-5-4SNRL-SQ- M1 -1 - 5G- XX- CPN3319 M 1 -5.3 Requires Lutron Backbox 241 -114 OMXSL-5-4SNRL-SQ- M2 -1 5G- XX- CPN3319 M2 -5 Requires Lutron Backbox 241 -114 OMXSL- 5- 4SNRL -SQ- BQA 5G- XX- CPN3319 Requires Lutron Backbox 241 -114 OMXSL- 5- 4SNRL -SQ- BQB 5G- XX- CPN3319 Requires Lutron Backbox 241 -114 1- BQA5.4 1- BQB5.4 r60 Ball Room A OMXSL- 6- 4SNRL -SQ- BA1 -BA6.2 6G- XX- CPN3319 Requires Lutron Backbox 241 -113 r61 Ball Room B OMXSL- 6- 4SNRL -SQ- BB1 -BB5.8 6G- XX- CPN3319 Requires Lutron Backbox 241 -113 "Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. January 22, 2010 BULLETIN #125 Page 10 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description Controlled r62 Presidential Suite OMX- 5C- DW- XX- CPN2174 P1 -P10 Entry 4 Scene, Off Preset Station r63 Presidential Suite OMX- 5C- DW- XX- CPN2174 P1 -P10 . Living 4 Scene, Off Preset Station r64, r65 Presidential Suite (2) OMX- 5C- DW- XX- CPN2174 P1 -P10 Dining Vestibule 4 Scene, Off Preset Station Two -gang Faceplate: AR- M2M2- DW2 -XX -E r66 REST OMX- 5C- DW- XX- CPN2174 R1 -R14 SERVICE STATION r67 Presidential Suite NTOMX - HHPJ -WH All Entry Closet Hand held Program Jack White Finish r68 Boardroom Entry OMX- 5C- DW- XX- CPN2174 BD1 -BD5 4 Scene, Off Preset Station r69 Boardroom Control OMXSL- 5- 45NRL -SQ- BD1 -BD5 Niche 5G- XX- CPN3319 Requires Lutron Backbox 241 -114 . "Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. . * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399. i January 22, 2010 BULLETIN #125 Page 11 FOUR SEASONS VAIL — Vail, Colorado REMOTE CONTROL STATION SCHEDULE Control Zones Station Location Description riation Controlled r70 Wall Niche OMXSL- 5- 4SNRL -SQ- M1 -1.1 —Ml-5.3 Meeting Room 1 OMX- RACP- 1A -XX -E M2- 1.1- M2 -5.3 Area Partition Control Partition Control Engraved r71 Sales Office OMX- 5C- DW- XX- CPN2174 S01 -S09 4 Scene, Off Preset Station r72 Sales Office OMX- 5C- DW- XX- CPN2174 S01 -S09 Conf_ Room 4 Scene, Off Station "Keyed scene select allows for clean -up scene selection when key is inserted and turned right. When key is returned to center position and removed, system returns to prior state, time clock is reactivated. * * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.