HomeMy WebLinkAboutB06-0196 Revision 49 IR 11440 Bulletin 125HKS
HILL GLAZIER STUDIO
REVIEVNED By
BULLETIN
PROJECT: Four Seasons Resort at Vail
Vail, Colorado
OWNER: Black Diamond Resort— Vail, LLC
Vail Development 09, LLC
Barclays Capital Real Estate
200 Park Avenue
New York, NY 10017
(212) 412 -1664
ARCHITECT: HKS Inc,
Hill Glazier Studio
925 Alma Street
Palo Alto, CA
94301
PROJECT #: 11247 / 02028
ARCHITECT'S
BULLETIN #: 125
DATE OF
ISSUANCE: 01/25110
Description:
Item #1 — Ski Rental and Sales Office Revision Revised level 5 admin /retail area per owner's direction.
See A2052 and A3052, revised door schedule, MCN #78, ECN #52, and revised lighting
drawings and specs
Item #2 — Mechanical Change Notice #78 Retail Area Revisions
Item #3 — Mechanical Change Notice #79 Loading Dock Sequence of Operations
Item #4 — Mechanical Site Instruction #91 Cooling Tower Freeze Protection
Item #5 — Mechanical Site Instruction #92 Multi -Zone AHU Control
Item #6 — Electrical Change Notice #52 Ski Boot Renovation
Attachments: (List attached documents that support description)
Architectural Drawings, dated 01/25/10, includes sheets A2052 and A3052.
Door Schedule, 1 page, dated 1/25/10
Mechanical Change Notice #78, dated 12/29/09, includes sheets M2052 and M3052, all dated 01/20/10
Mechanical Change Notice #79, dated 1/18110, includes sheets M5221 and M2061, all dated 01/19/10
Mechanical Change Notice #91, dated 1/18/10, includes sheets M522, all dated 01/18/10
�► Mechanical Change Notice #92, dated 1/18/10, includes sheets M522, all dated 01/19/10
HKS RIEN,
HILL GLAZIER STUDIO a
Electrical Change Notice #52, dated 1/22/10, includes sheets E2.05.2.2 and E3.05.2, all dated 01/22/10
Lighting Drawings, LT5.3 and LTC5.3, dated 1/22/10
Dimming Specification, dated 1/22/10, 1 page
End of Bulletin
Lighting Equipment Schedule, dated 1/22/10, 11 pages
Remote Control Station Schedule, dated 1/22/10, 11 pages
Lighting Cut Sheet, type J, J.1, J.2 & J.3, 2 pages
1
HILL GLAZIER BULLETIN #125
A r c h i t e c t s Issue Date 1/25/10
SECTION 08001 - DOOR_�C ,EPIJEE
J i
Door Exterior / Door Door HDWR Closer HDWR FIN. OPENING SIZE DOOR FRAME Armor(A) / Mop(M) /
No. Location Interior Ra'
LEVEL 5
HGA Project Number 02028
yp see legend) Width Height T hick Mat'I Fin at'I Finish Kick(K) Plate Remarks
PR 3'-6"
PR 3'-6"
P 3' -0"
' -0'
T -6"
PR 4' -0"
T-6"
' -0"
7'-
3
7- "
3'-6"
7
T-0
7'-6"
3' -0
8'-0"
T
-6"
3'
7 -
3
-
T -0"
7' -0"
PR T -0"
T -0"
-0"
T
9 1 -W
14'
29'-0
1 -3"
PR 7-
— 7-0"
3' -0"
7 - "
T-0", 2' -0"
7'-
T -0 -
T -0'
-0"
7'
2'-6"
'
TV'
3 -0"
— 7 r -o , ,
7' -0"
T -0"
7' -0"
T-0'
T -6"
3'-0"
7' -6"
3 -0
-6"
3 -0"
-0"
3. 6
T -0"
-0"
7-6
3
7'
'-0
7-
T
T -0"
S-0'
-0"
-0"
7'-0'
7'-
3'-0
7
-0
-6"
=30 -. _.
7 = 6 .
-0
7
3.
3-0 . ,
7147
'
P _0
-0„
7
PR 3'
T- 6 -
P R 3 -0"
R T -0"
7'
Four Seasons Resorts
Vail, Colorado
Page 9 of 24
�j� �rPI�7Le1� 0
"B
B
i�jL'�
Four Seasons Resorts
Vail, Colorado
Page 9 of 24
1AXXX MMM GROUP
Mr. John Curtis
Hill Glazier Studio
1 Vail Road
Vail, Colorado
81657
Project:
Vail Colorado - Four Seasons Hotels and Resorts
Medh.ahica
C hifi §e
Notice
Mechanical Change Notice No.
Revision:
78
Issue Date : Tuesday, December 29, 2009
Project Number. 1807286 -000
The follow ing items are proposed changes to the contract for this project. Unless noted below, work is not to proceed until authorized by a
change order. All material and workmanship are to be described in the contract documents unless otherwise stated. Please submit an
itemized quotation for changes to the contract value and /or to the project schedule.
Title: Retail Area Revisions
Reason for Change: OWNER
This change is a result of Ownership's request to revise the 5th floor area formally housing the Logo Shop. Please
note that the sprinkler layout will need to be revised to reflect the architectural changes.
Refer to M2.05.2 for HVAC revisions.
Refer to M3.05.2 for piping revisions.
END OF MECHANICAL CHANGE NOTICE
Adrian Duta
MMM Group
11MI M Group Limited - Consulting Engineers
100 Commerce Valley Drive West, Thornhill, ON Canada L3T 0A1
Bus: 905 -882 -1100 Fax: 905-882-7282
Website: www.mmm.ca
M )
Mecharcal
• +ANXX MMM GROU P Change
Notice
Mr. John Curtis
Hill Glazier Studio
1 Vail Road
Vail, Colorado
81657
Mechanical Change Notice No.
79
Project:
Vail Colorado - Four Seasons Hotels and Resorts
Revision:
Issue Date:
Project Number:
Monday, January 18, 2010
1807286 -000
The follow ing Revs are proposed changes to the contract for this project. Unless noted below, w ork is not to proceed until authorized by a
change order. All material and w orknwship are to be descrbed in the contract documents unless otherwise stated. Please submt an
itemized quotation for changes to the contract value and/or to the project schedule.
Title: Loading Dock Sequence of Operations
Reason for Change:
This change is issued as a clarification of the intended sequence of operations for the loading dock exhaust system
Refer to attached drawing M5.22.1 for the control sequence.
Refer to attached drawing M2.06.1 for the floor plan.
4
Adrian Duta
MMM Group
MMM Group Limited - Consulting Engineers
100 Commerce Valley Drive West, Thornhill, ON Canada L3TOA1
Bus:905 -882 -1100 Fax: 905 -882 -7282
Website: w w w .mrm.ca
Medical
A#AXXX MMMGROUP V
Site
Instru #ion
Mr. John Curtis Site Instruction No: 91
Hill Glazier Studio
1 Vail Road Issue Date: Monday, January 18, 2010
Vail, Colorado
81657 Project 1807286.000
Project:
Vail Colorado - Four Seasons Hotels and Resorts
Site instructions are issued only for the purpose of recording any clarification or interpretation of the contract document or giving direction
on problems resulting from field conditions. These instructions are subject to the provisions of the contract and w tl not affect the contract.
Should the Contractor require a change in the contract price or time, he shall advise the Architect w ithin seven days of receipt of this
instruction.
Cooling Tower Freeze Protection
This instruction is issued as a clarification of the control sequence for the cooling tower during free cooling mode.
Refer to attached drawing M5.22 for details.
, 4 —
Adrian Dula
MMM Group
cc: Inspection - M M Group
MM Group - Consulting Engineers
100 Commerce Valley Drive West, Thornhill 0nL3T0A1
Bus: 905 -882 -1100 Fax: 905 -882 -7282
uVrwchlasgrs11shn
Mechanical
MANN& MMM GROUP Site
Instruction
Mr. John Curtis Site Instruction No: gQ
3
Hill Glazier Studio
1 Vail Road Issue Date: Monday, January 18, 2010
Vail, Colorado
81657 Project 1807286 -000
Project:
Vail Colorado - Four Seasons Hotels and Resorts
Site Instructions are issued only for the purpose of recording any clarltication or interpretation of the contract document or giving direction
on problens resulting from field conditions. These instructions are subject to the provisions of the contract and will not affect the contract.
ShoWd the Contractor require a change in the contract price or time, he shall advise the Architect w Rhin seven days of receipt of this
instruction.
Multi Zone AHU Control
This instruction is issued in response to RFI -2871 to clarify the control diagram with regards to the multizone air
handling units Installed on site.
Please refer to attached drawing M5.22 for details.
0
Adrian Duta
MMM Group
cc: Inspection - MMM Group
MMM Group - Consulting Engineers
100 Commerce Valley Drive West, Thornhill OnL3T OA1
Bus: 905- 882 -1100 Fax: 905 -882 -7282
txVreW2rsgmsi1.sfm
I`\` MMM GROUP
John Curtis
HKS Hill Glazier Studio
1 Vail Road
Vail Colorado
81657
970 - 476 -7849
Project:
VAIL COLORADO - Four Seasons Hotels & Resorts
1 Vail Rd, Vail CO
Electrical
Change Notice
Electrical Change Notice No.
Revision:
Issue Date
Project Number.
52
Friday, January 22, 2010
1807286 -000
The following items are proposed changes to the contract for this project. Unless noted below, work is not to proceed until authorized by a
change order. All material and workmanship are to be described in the contract documents unless otherwise stated. Please submit an
itemized quotation for changes to the contract value and/or to the project schedule.
Title: Ski Boot Renovation
Reason for Change:
The purpose of this change is to revise the Logo Shop Area 546 on Level 5 to suit the new requirements.
1.0 General
1.1. Delete existing luminaires, power outlets and system outlets from area defined in attached sketches.
2.0 Level 5, Area 2 Area Plan Power & Signal - Dwg. E2.05.2 (Not Re- issued)
2.1. Revise power and systems in Logo Shop area and surrounding rooms as per attached sketch SKE-
2.05.2.2.
1.0 Level 5, Area 2 Area Plan Lighting/Reflected Ceiling - Dwg. E3.05.2 (Not Re-fssued)
2.2. Revise lighting in Logo Shop area and surrounding rooms as per attached sketch SKE- 3.05.2.1.
End of ECN #52
cc: Inspection - Rybka Smith & Ginsler Limited
Rybka, Smith & Ginsler Limited - Consulting Engineers
18 Champlain Boulevard, Toronto, Ontario M3H 2Z1
Bus: 416 - 398 -6020 Fax: 416 - 398 -6361 Night Line: 416- 398 -6090
E -mail: info @rybka.com Website: www.rybka.com
P5849iww . ..... - U
jT
-80
-
CONFERENCE
1 1 �5650 I
U -S2-16
------------ ] I. 1
j!P5B
56F I
n'
-T
11"51349
. ..... .... .
ARRIVAL
p ..... - --- --- . ....... .. ........ i
1345
AGM R5
• -01
fcu�'
i P51351
D
A - ER' R�.849.1 --- i.-j .-I it
.1- . . ............. - - --- - -- ----
...... .... 4 - -- -
---------
547'
Yom ........ . .....
.. . . .......... .
.AD
L . . ....... .. - ----- ---------
1 4 01 CL
7 . ....... . ... .....
K
P5E
P,5 11;
REQUEST FRS SALES
6
�---OFFICE—
ib
FRji
F -U
HELP 9
.... ..... . .. ...... ..... ........
P51J25 __ _.
- 546A
5B CLOSET
41
!P51342 PM
JPS2 14 546D
PS
MF 842
HE
25 SKL )T
1 FITTING
RE", L/"
546B
E5 6-g
51341
P
P5 32
AL .... . ...... . ......
....... ...
......... ...
. . ... ............
MV
i 545
1447
SO
READ THIS DWG, IN CONJUNCTION WITH DRAWING #E-
JOB FOUR SEASON - VAIL, COLORADO Scale
Date JAN. 22.10
A AM& DRAWING TITLE LEVEL-05, AREA-2, Drawn TG
MMM GROUP AREA PLAN, BY
"Ill I IM-1., Lioni..l POWER & SIGNAL - SKI BOOT RENOVATION Checked TG
Consul Lin Engl... re By
"11-11*i Job
Toronto, Ontario, M3H 221 Number 1807286005
Telephone: 416-398,6020
Drawing
INumber I SKE-2,052.2
Q,
5
D D SALES
I I - FFICE�,
i 546
. 504
C A.I I '
I � GI
.._..
- gt ._
_ 11
9
L'
A.
i
_.
HIGH LEVEL
_.
l '
GALLERY
545
E21.2
* P
--
:. P
- -� -
- -
�Y
Z46 C
C
%
E46:
4
(2)A.4 E24
(4 A.4
(2)A.4
e
READ THIS DWG. IN CONJUNCTION WITH DRAWING #E-
Q
JOB FOUR SEASON - VAIL, COLORADO
Scale
'"`
Date
JAN. 22.10
Drawn
DRAWING TITLE
LEVEL -05, AREA -2,
TG
MMM GROUP
AREA PLAN,
Rgbes. 6-1th & oils]- United
LIGHTINGAEFLECTED CEILING -
SKI BOOT RENOVATION
Checked
By
TG
C"su l ting Enginasrs
is C —'pl.m aeo]e.erd.
Toronto. 0-1i. M3H 2Z7
Job
Number
1807286005
T el c c n on e: 416.398 -6020
Drawing
Number
SKE- 3.05.2.1
0: \07 \180728600 \Electr1cal \plots \E3.05.2.dwg
January 22, 2oio
Bulletin #225 ` t '
Four Seasons Vail — Vail Colorado
DIMMING SPECIFICATION:
Lutron Grafik 7000
Zone
Dimming
VA
Load
Auxiliary
Number
Channel
Load
Type
Description
Equipment
Ski Shop
Lutron Grafik Eye (2) GRX - 3504 -A
-WH
SS1
1
2020
INC /LV
Linear Wallwasher
(b)
SS2
2
400
INC /LV
Downlight
(a)
SS3
3
225
INC /LV
Desk Accent
SS4
4
125
INC /LV
Art Accent
(a)
SS5
5
goo
INC /LV
Wall Washer
(a)(b)
SS6
6
300
INC /LV
Under shelves light
(a)
SS7
Spare
SS8
Spare
Sales Office
SO1
1
300
INC /LV
Pendant
502
2
125
INC /LV
Art Accent
(a)
SO3
3
188
INC /LV
Art Accent
(a)
SO4
4
375
INC /LV
Display Case Accent
SOS
5
125
INC /LV
Desk Accent
SO6
6
100
INC /LV
Wallwasher
SO7
7
200
INC /LV
Desk Accent
SO8
8
400
INC /LV
Wall sconces
SOg
g
500
INC /LV
Down Light
(a)
Auxiliary Equipment
(a) Provide Lutron Toroidal Choke sized as close to the load as possible or next higher size -load not to exceed l000 watts
(b) Zone requires Lutron Power Booster, NGRX -PB -WH
(c) Normal /Emergency Circuit
(d) Zone requires Lutron Fluorescent Interface GRX - FDBI -16A -120
(e) Zone requires GFCI Breaker
Load Type Abbreviations
INC/LV = Incandescent: Magnetic Low Voltage ELV = Electronic Low Voltage
NCC = Neon /Cold Cathode ND = Non -Dim
FDB = Fluorescent Dimming Ballast
LED = Light Emitting IOD
January 22, 2010 — Bulletin #125
Four Seasons Vail — Vail, Colorado
LIGHTING EQUIPMENT SCHEDULE
Type Description
A
Recessed Low Voltage PAR 36
Adj ustable Fixture
Champagne Cone
41/8" Aperture
A.1
Recessed Low Voltage Adjustable
Fixture
AR1ii Version
Champagne Cone
41/8 " Aperture
A.2
Recessed Low Voltage Adjustable
Fixture
A11=1 Version
Champagne Cone
41/8 " Aperture
A.3
Recessed Low Voltage Adjustable
Fixture
ARiii Version
Champagne Cone
41/8 " Aperture
A.4
Recessed Low Voltage PAR :t6
Adjustable Fixture
Champagne Cone
41/8" Aperture
A.5
Deleted
B
Recessed Par 3o Downlight
Champagne Cone
5" Aperture
Manufacturer No. Lama
Kurt Versen GE SoPAR36/VNSP
K7411 -BG
Voltage
120/12
Kurt Versen Phillips 120 /12
K7422 -BG ALU111MM- 75W- G53- 12V -8D
Kurt Versen Osram Sylvania SoAR111 /4° 120 112
K7411 -13G
Kurt Versen Phillips 12042
K7412 -BG ALU111MM-75W-GS3-12V-
24D
Kurt Versen GE 5oPAR36 /NSP 120/12
K7411 -BG
Kurt Versen
C7327 -BG
GE 7SPAR3o /H /FL25° 120
Page 2
January 22, 2010
Four Seasons
Vail — Colorado
LIGHTING EQUIPMENT SCHEDULE
Type
Description
Manufacturer
Lamp
Voltage
C
Recessed Lensed Wallwasher
Kurt Versen
GE iooPAR38 /HIR /FL40
120
Champagne Cone
E7528 -BG
5 7/8" Aperture
D
Recessed Small Aperture A -Lama
Kurt Versen
GE ioo /goW
120
Downlight
C7319-BG
Champagne Cone
41/8" Aperture
E
Low Voltage Recessed Downlight
Kurt Versen
GE Q5oMR16 /C /N5Pi5O
120/12
Champagne Cone
K7301 -BG
(EXT)
41/8" Aperture
F
Low Voltage Recessed
Kurt Versen
GE Q5oMR16 /C /NSP15
120/12
Adjustable Downlight
K7430 -BG
(EXT)
Champagne Cone
41/8" Aperture
G
Deleted
G.1
Recessed Lensed Wallwasher
Kurt Versen
GE 50PAR2o/H /NFL25°
120
Champagne Cone
E7S26 -BG
41/8" Aperture
G.2
Recessed Lensed Wallwasher
Kurt Versen
Philips
120
Champagne Cone
WE526
5oPAR2o /HAL /SPL /NFL3o°
41/8" Aperture
Brass base required
Wet Locations
H
Recessed Small Aperture Par 20
Kurt Versen
GE 5oPAR2o /H /NFL25°
120
Downlight (Front of House)
C73oo -BG -MOD
4" Aperture
Modified for 6" Depth
Modified for 6" Depth
H.1
Recessed Small Aperture Par 20
Kurt Versen
GE 5oPAR2o /H /NFL25°
120
Downlight
C73oo -BG
Champagne Cone
41/8" Aperture
I
Not Used
J
Recessed Small Aperture A -Lama
Kurt Versen
GE loo /goW
120
Downlight
C7322 -BG
5" Aperture Gold Trim
Page 3
January 22, 2010
Four Seasons Vail — Colorado
LIGHTING EQUIPMENT SCHEDULE
Type Description
Manufacturer
Lama Voltasm
11 Recessed Small Aperture A -Lamp
Kurt Versen
GE ioo /goW 120
Double - Wallwasher
E7522 -BG -D
(Front of House)
Double Wallwasher
5" Aperture Gold Trim
J.2 Recessed Small Aperture A -Lamp
Kurt Versen
GE ioo /goW 120
Downlighht- Wallwasher
E7522 -13G- Wallwasher
1.3 Recessed Small Aperture A -Lamp
Kurt Versen
GE ioo /goW 120
Downlight- Wallwasher
E7522 -BG -C
_5 Aperture Gold Trim
Corner Wallwasher
K.1 Linear Incandescent Strip
Alexandra & Co.
3 Watt Incandescent Frosted 120/24
With Festoon Sockets (a)
IllumiLite
2 1/4" O.C.
Series 78
Remote magnetic transformers
78- XX- AF- B- U -T2 -G
required. Refer to manufacturer's chart
for recommended wire size. Lengths to
be field verified. Contractor is
responsible for ordering the necessary
T2 terminals on the second end of the
strip. Strips must be ordered from the
factory with terminal connectors on
both ends of the light strip to make
tandem connecting possible. Contractor
to provide 10% overage of spare lamps.
K.2 Linear Incandescent Strip
Alexandra & Co.
5 Watt Incandescent Frosted 120124
With Festoon Sockets (a)
IllumiLite
21/4" O.C.
Series 78
Remote magnetic transformers
78- XX- AG- B- U -T2 -G
required. Refer to manufacturer's chart
for recommended wire size. Lengths to
be field verified. Contractor is
responsible for ordering the necessary
T2 terminals on the second end of the
strip. Strips must be ordered from the
factory with terminal connectors on
both ends of the light strip to make
tandem connecting possible. Contractor
to provide 10% overage of spare lamps.
January 22, 2010
Four Seasons Vail — Colorado
LIGHTING EQUIPMENT SCHEDULE
Type Description Manufacturer
K.3
Linear Incandescent Strip
Alexandra Lighting Co.
With Festoon Sockets (7a
IllumiLite
21/4"0
Series 78
Remote magnetic transformers
78- XX- AG- B- U -T2 -G
required. Refer to manufacturer's chart
for recommended wire size. Lengths to
be field verified. Contractor is
responsible for ordering the necessary
T2 terminals on the second end of the
strip. Strips must be ordered from the
factory with terminal connectors on
both ends of the light strip to make
tandem connecting possible. Contractor
to provide lo% overage of spare lamps.
L
DELETED
L.1
DELETED
M
DELETED
N
Picture Light -XXX Length
Alexandra Lighting Co.
S Watt Picture Light
Series 794
Lamps 4" o.c.
794 -PB- XX -X -X -X
Specify Projection
Unlacquered Polished
Length and projection to be determined
Brass
after art is selected
O
Not Used
P
Recessed A -Lamp Downlight
Kurt Verse
Champagne Cone
C7321 -BG
5 7/8" Aperture
Q
Recessed Low Voltage Double Lensed
Amerlux
Linear Wallwasher
LW WCDR- 35 -MR16-
Drywall
R EMOTE -M W- 120 -XX
Lamps 6" o.c.
Finish Color TBD
Contractor responsible for verifying
exact length per field measurements
Page 4
Lamp
Voltage
io Watt Incandescent Frosted 120/24
SWT3
GE 15oA/W
Soft White
GE Q35MR36 /C /SP20°
(FRA)
120/12
120
120/12
Page 5
January 22, 202.0
Four Seasons Vail - Colorado
LIGHTING EQUIPMENT SCHEDULE
tae Description Manufacturer Lamp Voltage
R
Recessed Low Voltage Small Aperture
Sylvan Alesco
GE 25R14SC /SP
120/12
Downlight
A8600TB- ALR1425
Included
Remote transformer required
Contractor to provide shop
drawings showing
transformer layout and
sizes
S
Low Voltage Linear Lighting for
Roberts Step -Lite
Lamps included
120/12
Banquets and for Mirrors at Spa
RA -12 Series
Remote Transformer Required
RA- 12- EB -CL -XX
Lengths to be field
verified
S.1
Linear LED Night Light
Roberts Step -Lite
Lamps included
120/12
12 Vdc drive required
RW12- LED -285oK
T
Recessed T -4 Downlight in Ballroom
Kurt Versen
GE 25oT -4 /Frosted
120
Champagne Trim
C7394 -BG
7 1 /4" Aperture
U.1
Surface Mounted 2 ft. Incandescent
Alkco
Supplied with fixture
120/12
Strip Fixture
HG23 /10 /SGD
V
Recessed Floor Column Uplights (al
BK Lighting
GE Q5oMR16 /C /NSP15° (EXT)
120/12
Living Room
MR16 Recessed Fixture
4 -5/8" Diameter
CUS- 1403 -22
Finish to match floor
W
iW Profile G2- Narrow Beam LED
Color Kinetics
LED Included
120/24
Fixture
to supply the following
15 W /FT.
Contractor to field measure for exact
pieces of equipment
length.
1o° x 11o° Beam Angle
(a) Aux Box
103 - 000021 -01
(b) Mayer 3
103 - 000019 -00
(c) iW PDS -15o
509 - 000001 -00
(d) iW Profile G2
Narrow Beam
_
501 - 000010 -01
W.1
Linear LED in Handrail
Alexandra Co.
Lamps included . µ
io /x2
12W per Linear Feet
24L- XX- C -6 -12-
Voltage
120
120
120
220
120/12
120/12
120/12
120
120
120/12
120/12
Page 6
January 22, 2010
Four Seasons Vail — Colorado
LIGHTING EQUIPMENT SCHEDULE
Type
Description
Manufacturer
Lamp
W2- 1/2- P2 -D -1
X
Cold Cathode
Neotek, Inc.
12oma
(High Power Factor)
817.640.4300
Incandescent White
2400K, 25mm
(6 Watts per Linear ft.)
Y.3
Surface Mounted 3 ft. Fluorescent Strip
Columbia
GE
Fixture
CN- 3 -1 -39 -EB5 -120
F39W/T5 / /HO
Y.4
Surface Mounted 4ft. Fluorescent
Columbia
GE
Strip Fixture
CN- 4 -1 -54- EB5 -120
F54W/T5 /83o /HO
Z
Porcelain Socket Keyless
Leviton
GE 15oA /W
AA
MR16 Exterior Monopoint Wall
B -K Lighting
GE Q5oMR16 /C /NFL25
Mounted Grazer
Night Star II
(EXZ)
NSI I -7- BZP -13
With Canopy
BC6 -BZP
BB
Exterior Step Light
B -K Lighting
GE Q5oMR16 /C /NSP15
Must be mounted a minimum of 12"
Step Star
(EXT)
above tred.
SS -6 -BZP -A
Remote transformer required.
CC
Exterior Recessed Ground Uplight
B -K Lighting
GE Q5oMR16 /C /NSP15
Remote transformer required
B- HP2- MR -RS -6 -BZP -CPC
(EXT)
(no honeycomb baffle)
DD
Surface Horizontal- mounted Closet
Lightolier
(2) GE 6oA19/W
Light
Opalux 6 34 8
EE
Recessed Spa Corridor Foot Lights
10 Lighting
LED
o- o1- SL- A- 3K- 100 -2 -0
FF
Recessed Wet Location Spa Shower
BEGA
2oWG4
Lights
1121
Included
GG
Recessed Low Voltage Double Lensed
Amerlux
GE 035MR16 /C /SP20°
Linear Wall Grazer
LWGCDR- 35 -MR16-
(FRA)
Lamps Space 6 "o.c.
Remote -MW- 120 -XX -WET
WET location
Finish Color TBD
Contractor responsible for verifying
exact length per field measurements
Voltage
120
120
120
220
120/12
120/12
120/12
120
120
120/12
120/12
KK
LL
MM
NN
00
PP
QQ
Deleted
Wall Mounted Path Light
Bega
Page 7
January 22, 2010
Tree Mounted Downlight
BK Lighting
Four Seasons Vail — Colorado
Delta Star
LIGHTING EQUIPMENT SCHEDULE
Tree Strap
Type Description
Manufacturer
Lamp
GG.1 Recessed Low Voltage Double Lensed
Amerlux
GE 035MR16 /C /SP20°
Linear Wall Grazer
LWGCDR- 35 -MR16-
(FRA)
Lamps Space 6" o.c.
Remote -MW- 120 -XX
A- CUS36 -B -BZP
Finish Color TBD
Contractor responsible for verifying
exact length per field measurements
HH Exterior Fountain Light
Hydrel
1ooQ LAMP INCLUDED
Contractor to determine conduit entries
44:L3 -1000- 120- FLC -NM-
and cord length.
XX- XX -LPI
II Not Used
JJ Entry Pole
Neri Pole
1ooMH
Lamp to be horizontal mounted
8016.00
Neri Lantern
ARCO LA500
KK
LL
MM
NN
00
PP
QQ
Deleted
Wall Mounted Path Light
Bega
Black Finish
2295 -P
Tree Mounted Downlight
BK Lighting
Delta Star
DS -8- BZP -9 -A with
Tree Strap
TS- MB- Z- BZP -XX
Tree Mounted Uplight with Adjustable
BK Lighting
Power Pie up to 36"
Delta Star
DS -7- BZP -9 -A with
adjustable power pipe PP-
A- CUS36 -B -BZP
Not Used
Emergency Path Light
NOT USED
27 Watt CF Twin 4 -P
Osram /Sylvania
#FT24 DL /83o /ECO
GE Q5oMR16 /C /FL40°
(EXN)
GEQ50MR16 /25°
FX Luminaire 20 Watt
Demilite DL- 2o- 18R -BZ Xenon
Voltage
120/12
120
120
277
120/12
120/12
120/12
Voltage
120/12
120/12
120
120
120/12
120/12
120/12
120
Page 8
January
22, 2010
Four Seasons Vail — Colorado
LIGHTING EQUIPMENT SCHEDULE
Type
Description
Manufacturer
Lamp
RR
Recessed
Hydrel
GE Q5oMR16 /C /NSPi5*
Wet Location
4800- SQ- B- M75- 12 -FL-
(EXT)
Whirlpool Fixture
CLC- NM- 3445B-RG- ? ? ? -LP
SS
Surface Mounted
BK Lighting
GE QSoMR16 /C /NFL25°
Monopoint Fixture
DS- 7- BZP -9 -B
(EXZ)
with BC4 -BZP
TT
Recessed Niche Mount Wet Location
Hydrel
2000 Watt PAR64 Lamp
Pool Fixture
4427- B- P6410001- 12o -NSP-
Included
Bronze Finish
CLC-NM-34B-RG-CSLXX-
With Rock Guard
LPI
Contract responsible for verifying length
of cord (CSLXX)
UU
Bollard
Louis Poulsen
BYS411ooW /H PS/ED
Medium /120/ COR -TEN
V V
Deleted
WW
Deleted
XX
Vail
US Long Life
HPSiooEi7
Citypole
TOVSS9644PH
City to Select
YY
Retail Recessed
Belfer Virtual Axis
GE
Multi -Point Fixture io'
161- XX- BP- HP- I -DT -WH
Q5oMR16 /HIR /CG10
YY.1
Retail Recessed
Belfer Virtual Axis
GE
Multi -Point Fixture S'
161 -XX BP HP -1 DT -WH
QS0MR16 /HIR /CG10
YY_z
Retail Recessed
Belfer Virtual Axis
GE
Multi -Point Fixture 4'
161- XX- BP- HP- I -DT -WH
05oMR16 /HIR /CG10
ZZ
Wallmount Door Exit Light
BK Lighting
GE Q37MR16 /C /CG40
El Capitan
EC -5- BZP -9 -B
AAA
Deleted
AAA.1
Deleted
BBB
Deleted
Voltage
120/12
120/12
120
120
120/12
120/12
120/12
120
January 22, 2010
Four Seasons Vail — Colorado
Page g
LIGHTING EQUIPMENT SCHEDULE
ape
Description
Manufacturer
Lama
Voltage
CCC
Deleted
DDD
Deleted
EEE
Deleted
FFF
Deleted
GGG
Deleted
GGG.i
Deleted
HHH
Recessed Step Light
Belfer Lighting
3.75 Watt
120/
Must be mounted a minimum of 12"
331oFP- XX- R -31 -24
Lamp Included
24
above tread
iii
Surface Mounted Quartz Uplight White
Belfer Lighting
GE (2)Qioo /DC /Frosted
220
723o -WH
KKK
Surface Mounted 4' -0" Linear Cove
Focal Point
GE F32T8 /SP3o /ECO
120
Light with T8 Lamp
FCVA-26-iT8-iC-120-D-
Lutron Dimmable Ballast Required
CV -HW -4'
KKK.1
Surface Mounted 3' -0" Linear Cove
Focal Point
GE F25T8 /SP3o /ECO
3.20
Light with T8 Lamp
FCVA-26-iT8-2C- 220 -D-
Lutron Dimmable Ballast Required
CV -HW -3'
LLL
Surface Mounted z' -o" Linear Ts
Bartco Lighting
Sylvania FPi4 /830
120
Fluorescent Fixture
BFL -1 4
Remote Ballast Required
MMM
Surface Mounted - A' -o" Linear TS
Bartco Lighting
Sylvania FP21 /830
120
Fluorescent fixture in the display case
BF- CH- 21 -X -XX
at Logo Shop
Remote Ballast Required
Electrical Contractor to verify length of
cable and feed location prior to ordering
NNN
Recessed PAR 18 Wall Washer
Kurt Versen
GE 12oPAR /H /FL30
120
5 7/8" Aperture
E7528 -BG
000
Not Used
PPP
Not Used
January 22, 2010
Four Seasons Vail — Colorado
LIGHTING EQUIPMENT SCHEDULE
Page io
Type
Description
Manufacturer
Lamp
QQQ
Recessed in wall LED Floor Washlight
Erco Lighting
Blue LED
CARLON FLOORBOX
337 w /Silver finish
Per Manufacture's spec
LWR Dimmable Duplex Wall Receptacle and
Lutron (Receptacle)
33858.023— Control Gear
NTR-1s- DFDU -BR-
CPW0441
33 - Housing
Lutron (Receptacle)
RRR
Recessed Small Aperture A -Lamp
Kurt Versen
GE loo /9oW
Wallwasher
E7519 -BG
RP- FDU -10 -COLOR
Champagne Cone
41/8" Aperture
SSS
PAR20 Cove medium base
Belfer Lighting
Philips
incandescent extrusion
2502- 12- S -F -xx
5oPAR2o /HAL /SPL /NFL30
Straight
With linera spread lens
Brass bass required_
Sockets at 12" O.0
(part# LP2052) for each
Contractor to filed measure for exact
lamp
length
LFR Dimmable Duplex Floor Receptacle Lutron (Receptacle)
and Plug NTR-I5- DFDU -GR-
Contractorto hold plugs and install CPW0441
on all lamps during installation Lutron (Receptacle)
NTR-2o- DFDU -GR-
CPW0442
Lutron (Plug)
RP- FDU -10 -COLOR
Voltage
120/30
120
120
CARLON FLOORBOX
P/N E976RFB
CARLON ACTIVATION
KIT P/N E97AK2
CARLON FLOORBOX
E976RFB
LWR Dimmable Duplex Wall Receptacle and
Lutron (Receptacle)
Plus
NTR-1s- DFDU -BR-
CPW0441
Contractor to hold plugs and install on all
Lutron (Receptacle)
lamps during installation
NTR-2o- DFDU -BR-
CPW0442
Lutron (Plug)
RP- FDU -10 -COLOR
Voltage
120/30
120
120
Page ii
January 22, 2010
Four Seasons Vail — Colorado
LIGHTING EQUIPMENT SCHEDULE
Type Description Manufacturer Lamp Voltage
Note #i: Lighting consultant, Bouyea & Associates, will travel to the jobsite and supervise final adjustments (aiming) to all
adjustable light fixtures. The electrical subcontractor shall provide six (6) electricians to work with the lighting
consultant for a period of four (4) days. Most of this work will occur after sundown (plan: 7pm -3am). The contractor
should also be prepared to supply ladders and manlifts to reach the recessed fixtures.
Note #2: Electrical subcontractor to hold an allowance of $2,000.00 US dollars to supply additional lamps for fixtures to be used
in the focusing of lighting phase of the project. The lighting consultant, Bouyea & Associates, will supply a list of
lamps to be purchased within 4 -6 weeks of their trip to the jobsite to focus the lighting. Contractorto receive these
lamps and store them at thejobsite. The unused portion of lamps is then to be turned over to the hotel as attic stock.
BULLETIN IM0
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control
Zones
Station Location
Description
Controlled
TBD
G7- AR- W000 -0 -120
Grafik 7000 Central Processor
TBD
PJ62- ADPT -1
Jack Adaptor
TBD
NTOMX- 62J -WH
TBD
OMX -RS232
Touch Screen Interface
TBD
(3) OMX -AV
LV Contact Closure Interface
TBD
GR6HHP Hand Held Programmer
r1 Electrical Room G -502
NTOMX - HHPJ -WH
All
(By Residence Club
Hand Held Program Jack
Lobby)
White Finish
r2 Stair 'U'
NTOMX - HHPJ -WH
All
S -519
Hand Held Program Jack
(By Lobby Bar)
White Finish
r3 Concierge Vestibule
NTOMX - HHPJ -WH
All
R -3
Hand Held Program Jack
White Finish
r4 SKI /Golf Bag
NTOMX - HHPJ -WH
All
Storage
Hand Held Program Jack
Room 513
White Finish
January 22, 2010
BULLETIN #125
Page 2
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control
Zones
Station
Location
Description
Controlled
r5
Maid's Room
NTOMX - HHPJ -WH
All
G -519
Hand Held Program Jack
(By Exterior)
White Finish
r6
Valet Room
NTOMX - HHPJ -WH
All
534
Hand Held Program Jack
White Finish
r7
Service Station
NTOMX - HHPJ -WH
All
352
Hand Held Program Jack
White Finish
r8
Door Check
NTOMX - HHPJ -WH
All
355A
Hand Held Program Jack
White Finish
r9
Coat Check
NTOMX- HHPJ -WH
All
372
Hand Held Program Jack
White Finish
r10
Wall Niche
NTOMX - HHPJ -WH
All
Meeting Room 1
Hand Held Program Jack
White Finish
r11
Wall Niche
NTOMX - HHPJ -WH
All
Meeting Room 2
Hand Held Program Jack
White Finish
r12
Vestibule
NTOMX - HHPJ -WH
All
373
Hand Held Program Jack
White Finish
**Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior state, time clock is
reactivated.
* * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.
January 22, 2010
BULLETIN #125
Page 3
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control
Zones
Station
Location
Description
Controlled
r13
Vestibule
NTOMX - HHPJ -WH
All
375
Hand Held Program Jack
White Finish
r14
Hallway
NTOMX - HHPJ -WH
All
305
Hand Held Program Jack
White Finish
r15
Hallway
NTOMX- HHPJ -WH
All
305
Hand Held Program Jack
White Finish
r16
Janitor's Closet
NTOMX - HHPJ -WH
All
389
Hand Held Program Jack
White Finish
r17
Boardroom
NTOMX - HHPJ -WH
All
378 (To be mounted
Hand Held Program Jack
In base cabinet)
White Finish
r18
Electrician's Room
NTOMX - HHPJ -WH
All
218
Hand Held Program Jack
White Finish
r19
Office
NTOMX - HHPJ -WH
All
234
Hand Held Program Jack
White Finish
r20
Storage
NTOMX - HHPJ -WH
All
233
Hand Held Program Jack
White Finish
"Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior state, time clock is
reactivated.
* * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.
January 22, 2010
BULLETIN #125
Page 4
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control
Zones
Station Location
Description
Controlled
r21 Spa Administration
NTOMX - HHPJ -WH
All
242
Hand Held Program Jack
White Finish
r22 Mechanical Room
NTOMX - HHPJ -WH
All
265
Hand Held Program Jack
White Finish
r23 Janitor's Closet
NTOMX - HHPJ -WH
All
253
Hand Held Program Jack
White Finish
r24 Vestibule
NTOMX - HHPJ -WH
All
275A
Hand Held Program Jack
White Finish
r25 Prep Room
NTOMX - HHPJ -WH
All
285
Hand Held Program Jack
White Finish
r26 Janitor's Closet
NTOMX - HHPJ -WH
All
269
Hand Held Program Jack
White Finish
r27 ** Vestibule
NTOMX-KS-CF-XX-CPN3254
E1 -E55
538
NTOMX- 4S- NRL -XX
LL1 -LL8
Key Control Station with
LB1 -LB11
4 Scenes, Off
1-1 -1-9.4
Two -gang
Faceplate: NT- T21T13- FB -XX -E
* *Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior state, time clock is
reactivated. -
* * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.
January 22, 2010
BULLETIN #125 Page 5
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control
Zones
Station
Location
Description
Controlled
r28 **
Stair'U'
NTOMX-KS-CF-XX- CPN3254
E1 -E55
S -519
NTOMX -4S- NRL -XX
LL1 -LL8
Key Control Station with
LBl -LB11
4 Scenes, Off
1-1 -1-9.4
Two -gang
Faceplate: NT- T21T13- FB -XX -E
r29 **
Electrical Closet
NTOMX- KS- CF -XX- CPN3254
RL1 -RL10
G -502
NTOMX -4S- NRL -XX
Key Control Station with
4 Scenes, Off
Two -gang
Faceplate: NT -T21 T13- FB -XX -E
r30 **
Service Station
NTOMX- KS- CF -XX- CPN3254
R1 -R14
352
NTOMX -4S- NRL -XX
PD1 -PD5
Key Control Station with
4 Scenes, Off
Two -gang
Faceplate: NT-T21 T1 3-FB-XX-E
r31 **
Janitor's Closet
NTOMX- KS- CF -XX- CPN3254
E1 -E54
363
NTOMX4S- NRL -XX
MP1 -MP7
Key Control Station with
BQP1 -BQP5
4 Scenes, Off
BP1 -BP12
Two -gang
Faceplate: NT- T21T13- FB -XX -E
r32 **
Hallway
NTOMX- KS- CF -XX- CPN3254
BQP1 -BQP5
C -305
NTOMX -4S- NRL -XX
BPI-BP12
Key Control Station with
E1 -E54
4 Scenes, Off
MP1 -MP7
Two -gang
Faceplate: NT- T2lT13- FB -XX -E
* *Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior state, time clock is
reactivated.
* * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.
January 22, 2010
BULLETIN #125 Page 6
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDU
Control
Zones
Station
Location
Description
Controlled
r33 **
Janitor's Closet
NTOMX- KS- CF -XX- CPN3254
ML1 -ML22
253
NTOMX -4S- NRL -XX
WL1 -WL16
Key Control Station with
4 Scenes, Off
Two -gang
Faceplate: NT- T21T13- FB -XX -E
r34 **
Vestibule
NTOMX- KS- CF -XX- CPN3254
TC1 -TC7
275A
NTOMX -4S- NRL -XX
TR1 -TR12
Key Control Station with
4 Scenes, Off
Two -gang
Faceplate: NT- T21T13- FB -XX -E
r35 **
Electrical Room
NTOMX- KS- CF -XX- CPN3254
E1 -E54
218
NTOMX -4S- NRL -XX
SR1 -SR8
Key Control Station with
Y1 -Y6
4 Scenes, Off
KC1 — KC6
Two -gang
C1 -05
Faceplate: NT- T21T13- FB -XX -E
r36
Hallway
OMX- RACP- 1A -XX -E
Partition Control
C -305
Area Partition Control
BA1 -BA6.2
Engraved
BB1 -BB5.8
Requires Lutron Backbox
r37
BALLROOM
OMX- 5C- DW- XX- CPN2174
M1 -1
4 Scene, Off Preset Station
BP1 -BP12
Engraved`
* *Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior state, time clock is
reactivated.
* * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.
January 22, 2010
BULLETIN #125 Page 7
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control Zones
Station
Location
Description
Controlled
r38
Vestibule
OMX- RACP- 1A -XX -E
Partition Control
Area Partition Control
BQA1- BQA5.4
Engraved
BQB1- BQB5.4
Requires Lutron Backbox
r39
Meeting Room 1
OMX- 5C- DW- XX- CPN2174
M1 -1
4 Scene, Off Preset Station
M1 -5
Engraved
r40
Meeting Room 1
OMX- 5C- DW- XX- CPN2174
M1 -1
4 Scene, Off Preset Station
M1 -5
Engraved
r41
Meeting Room 2
OMX- 5C- DW- XX- CPN2174
M2 -1
4 Scene, Off Preset Station
M2 -5
Engraved
r42
Meeting Room 2
OMX- 5C- DW- XX- CPN2174
M2 -1
4 Scene, Off Preset Station
M2 -5
Engraved
r43
Banquet Room A
OMX- 5C- DW- XX- CPN2174
BQA1- BQA5.4
4 Scene, Off Preset Station
Engraved
r44
Banquet Room A
OMX- 5C- DW- XX- CPN2174
BQA1- BQA5.4
4 Scene, Off Preset Station
Engraved
r45
Banquet Room B
OMX- 5C- DW- XX- CPN2174
BQB1- BQB5.4
4 Scene, Off Preset Station
Engraved
r46
Banquet Room B
OMX- 5C- DW- XX- CPN2174
BQB1- BQB5.4
4 Scene, Off Preset Station
Engraved
"Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is
returned to center position and removed, system returns to prior
state, time clock is'
reactivated.
- * * *OMS- 5C-
DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.
January 22, 2010
BULLETIN #125
Page 8
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control
Zones
Station Location
Description
Controlled
r47 Ball Room A
OMX- 5C- DW- XX- CPN2174
BA1 -BA6.2
4 Scene, Off Preset Station
Engraved
r48 Ball Room A
OMX- 5C- DW- XX- CPN2174
BA1 -BA6.2
4 Scene, Off Preset Station
Engraved
r49 Ball Room B
OMX- 5C- DW- XX- CPN2174
BB1 -BB5.8
4 Scene, Off Preset Station
Engraved
r50 Ball Room B
OMX- 5C- DW- XX- CPN2174
BB1 -BB5.8
4 Scene, Off Preset Station
Engraved
r51 Private Dining
OMX- 5C- DW- XX- CPN2174
PD1 -PD5.2
4 Scene, Off Preset Station
Engraved
r52 Spa Reception
OMX- 5C- DW- XX- CPN2174
SR1 -SR8
4 Scene, Off Preset Station
Engraved
r53 Salon
OMX- 5C- DW- XX- CPN2174
S1 -S8
4 Scene, Off Preset Station
Engraved
r54 Storage 233
OMX- 5C- DW- XX- CPN2174
FC1 -FC5
4 Scene, Off Preset Station
Engraved
"Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior
state, time clock is
reactivated.
* * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.
January 22, 2010
BULLETIN #125
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control
Station Location
r55 Fire Command
r56 Wall Niche
Meeting Room 1
r57 Wall Niche
Meeting Room 2
r58 Banquet Room A
r59 Banquet Room B
Page 9
Zones
Description Controlled
OMX- 5C- DW- XX- CPN2174 EX1 -EX27
4 Scene, Off Preset Station ST1 -ST4
Engraved T1 -T2
OMXSL-5-4SNRL-SQ- M1 -1 -
5G- XX- CPN3319 M 1 -5.3
Requires Lutron Backbox 241 -114
OMXSL-5-4SNRL-SQ-
M2 -1
5G- XX- CPN3319
M2 -5
Requires Lutron Backbox 241 -114
OMXSL- 5- 4SNRL -SQ-
BQA
5G- XX- CPN3319
Requires Lutron Backbox 241 -114
OMXSL- 5- 4SNRL -SQ-
BQB
5G- XX- CPN3319
Requires Lutron Backbox 241 -114
1- BQA5.4
1- BQB5.4
r60 Ball Room A OMXSL- 6- 4SNRL -SQ- BA1 -BA6.2
6G- XX- CPN3319
Requires Lutron Backbox 241 -113
r61 Ball Room B OMXSL- 6- 4SNRL -SQ- BB1 -BB5.8
6G- XX- CPN3319
Requires Lutron Backbox 241 -113
"Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior state, time clock is
reactivated.
* * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.
January 22, 2010
BULLETIN #125
Page 10
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control
Zones
Station Location
Description
Controlled
r62 Presidential Suite
OMX- 5C- DW- XX- CPN2174
P1 -P10
Entry
4 Scene, Off Preset Station
r63 Presidential Suite
OMX- 5C- DW- XX- CPN2174
P1 -P10
. Living
4 Scene, Off Preset Station
r64, r65 Presidential Suite
(2) OMX- 5C- DW- XX- CPN2174
P1 -P10
Dining Vestibule
4 Scene, Off Preset Station
Two -gang
Faceplate: AR- M2M2- DW2 -XX -E
r66 REST
OMX- 5C- DW- XX- CPN2174
R1 -R14
SERVICE STATION
r67 Presidential Suite
NTOMX - HHPJ -WH
All
Entry Closet
Hand held Program Jack
White Finish
r68 Boardroom Entry
OMX- 5C- DW- XX- CPN2174
BD1 -BD5
4 Scene, Off Preset Station
r69 Boardroom Control
OMXSL- 5- 45NRL -SQ-
BD1 -BD5
Niche
5G- XX- CPN3319
Requires Lutron Backbox 241 -114
. "Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior state, time clock is
reactivated.
. * * *OMS- 5C- DW- XX -CPN 2174 stations
require Lutron provided backbox, part number 241 -399.
i
January 22, 2010
BULLETIN #125 Page 11
FOUR SEASONS VAIL — Vail, Colorado
REMOTE CONTROL STATION SCHEDULE
Control Zones
Station Location Description riation Controlled
r70 Wall Niche OMXSL- 5- 4SNRL -SQ- M1 -1.1 —Ml-5.3
Meeting Room 1 OMX- RACP- 1A -XX -E M2- 1.1- M2 -5.3
Area Partition Control Partition Control
Engraved
r71 Sales Office OMX- 5C- DW- XX- CPN2174 S01 -S09
4 Scene, Off Preset Station
r72 Sales Office OMX- 5C- DW- XX- CPN2174 S01 -S09
Conf_ Room 4 Scene, Off Station
"Keyed scene select allows for clean -up scene selection when key is inserted and turned right.
When key is returned to center position and removed, system returns to prior state, time clock is
reactivated.
* * *OMS- 5C- DW- XX -CPN 2174 stations require Lutron provided backbox, part number 241 -399.