HomeMy WebLinkAboutVAIL VILLAGE FILING 1 BLOCK 6 LOT 6 RIVA RIDGE NORTH UNIT 645.PDF , � l� �C'�l
rn' �
� �,
. -� �`
� � �
- � �
_ 'I.�L.
� D E M 0 L I T I � N N ❑ T E S ; G E N E R A L N ❑ T ES � ROOM FlNISH SCHEDULE DOOR 3CHEDULE REVISIONS s� � � ��
FLOOR ARl� TYPE ���� DOOR A�AT. FRAf�IE B�AAT. REA�A��S � �
BASE vnon� H�cr+r Tr+iac
1, THE CONTRACT�R SHALL INSPECT ALL EXISTING CONDITIONS, VERIFY ALL ❑N—SITE WALLS
1 A 2'-4" 6'-8 1'/e' S_C WOOD WOOD FLUSH
O MASTER BATHR�OM DIMENSI�NS, STRUCTURAL SYSTEMS, EQUIPMENT AND BUILDING SERVICE REQUIRMENTS CEILING 02 A 2'—s" s'—$ �'j; S C WOOD WOOD FLUSH
� A� REMOVE EXISTING WALLS, DR�PPED CLG„ D�OR AND FRAME AS INDICATED, PRI�R TO C�MMENCEMENT �F W�RK, ❑RGTNAL BUILDING PLANS SHOULD BE REVIEWED s A z�—e° s�—s �'/;' s C wOOD WooD FLUSH
FL�f]R C❑VERING AND BASE AS REQUIRED FOR NEW MASTER BATH TO ASSESS THE ENTIRE SC�PE OF THE PR�JECT WHEN P�SSIBLE� ** ** ** ** �
CONFIGURATI�N CSEE F"L��R PLAN> 2� THE C[]NTRACT�R SHALL BE RE�PONSIBLE F�R C�ORDINATION WITH ALL ❑THER 4 B 2'—s" 6'-8 1%s S C WOOD WOOD BI—FO�o
PATCH WALL AS REQUIRED TO MATCH EXISTING. TRADES INCLUDING THE EXISTIrG STRUCTURAL ELEMENTS OF THE BUILDING, 1 CARPET - VERIFY TYPE & STYLE w/ OWNER
2 CERAMIC 11LE - VERIFY TYPE & STYLE w/ OWNER 5 B 3'-0" 6'-8' 1%s S C WOOD WOOD BI-FOLD
B) REMOVE ALL PLUMBING FIXTURERS, CAP ❑FF 3, THE C�NTRACT�R SHALL PROVI]�E ALL ELEMENTS �F THE SYSTEMS AS INTENDED BY 3 WOOD - VERIFY Tl'PE & STYLE w/ OWNER sO C 4'-0" 6'-8 1% S C WOOD WOOD HORIZ SLIDER
EXISTING �AV, PLUMBING IN WALL, 7HE DESIGN TO RESULT IN C�MPLETE AND WORKABLE SYSTEMS IN ACCORDANCE WITH ALL 4 TRAVER1lNE - VERIFY w/ owNER
C) REMOVE EXISTING C�NCRETE TOPPING AND STATE AND L�CAL C❑DES, SAFE�Y STANDARDS AND GOVERNING ❑RDINANCES� 5 GYPSUM WALLBOARD - PAINTED 7O C 6'-0" 6'-8 1%s S C WOOD WOOD HORIZ SLIDER
PLYW❑OD SUB-FL❑�RING AS REQUIRED FC1R THE � 6 MOISTURE RESISTANT GYPSUM WALLBOARD - PAINTED 3
4, THE CONTRACTOR SHALL BE RE.P�NSIBLE F�R REMOVAL OF ALL DEBRIS FROM OS A 2'—s" s'—s' �/;' S C WOOD WOOD POCKET DOOR
REL�CATIDN �F THE PLUMBING FIXTURERS, VENT AND THE PROJECT SITE IN ACCaRDAtiCE WITH ALL APPLICABLE TOWN OF VAIL REQUIREMENTS. 7 CERAMIC TILE OVER M.R GYP e�
DRAIN LINES, <SEE FLO❑R PLAN AND RISER DIAGRAMS) FLOOR TO CEILING, ALL WALLS � TUB AND/OR SHWR
PATCH FL��R 7❑ MATCH EXISTING, 5, MAINTAIN ALL APPLICABLE FIRE RATINGS AT ALL VERT, AND HOR, PENETRATIONS, s GYPBD ovER tx2 w� FURRING STRIPS � 16" o c DOOR TVPE3
I,E, MECHANICAL AND ELECTRICPL SERVICE RUNS� OVER EXISTING GYP op CEILING SMOOTH PAINTED FINISH DOOR NOTES:
O MASTER BEDR�OM 6, IF ANY CLARIFICATION OF DRA4'INGS ARE REQUIRED ❑R ANY 9 HARDWOOD FLOORING - VERIFY TYPE & STYLE w/ * REPLACE FRONT DOOR LOCKS AND
DISCREPANCIES N�TICED BY THE GENERAL CONTRACT�R ❑R w/ oWNER, & INSTALL AS PER MFGR'S RECOMMENDATIONS � � � � � � � � PRO\'IDE OWNER w� 2 KEYS �
A) REM❑VE EXISTING WALLS, DROPPED CLG„ D�ORS AND FRAMES AS INDICATED, 10 T&G WD ClG - VERIFY TYPE & STYLE w/ � � � � � � � � VERIFY STYLE w OWNER
FLO�R C❑VERING AND BASE AS REQUIRED FOR NEW MASTER BEDROOM CL�SET HIS SUBS DURING THE BIDDING PROCESS, THEY SHALL BRING w/ OWNER & INSTALL OVER 2x4 WD SLEEPERS FASTENED /
CONFIGURATI�N <SEE FL��R PLAN> THEM TO THE ATTENTION pF TFE ARCHITECT FDR CLARIFICATI�N, TO EXISTING WOOD TRUSSES w/ CABINET SCREWS
PATCH WALLS AS REQUIRED T❑ MATCH EXISTING, -" "-'
7. FRAMING — STUD WALL SHALL BE 2x4 WO�D STUDS @ 24' c/c � � � � � � � �
O ENTRY/F�YER <INTERI�R) WITH <1> 2x4 P,T, S LL PL & Cl) 2x4 TOP PL,, ❑R 3 5/8' MTL, STUDS FlNISH NOTES:
8, ALL W�[]D IN CONTACT WITH CONCRETE SHALL BE P,T, * FINISH IN CLOSETS AR� THE SAME AS THE
A) REM�VE EXISTING WALLS, DR�PPED CLG, D�OR AND FRAME AS INDICATED, 9, ALL OTHER STUD WALL. HEADER> C2) 2x6 WITH SPACER� ROOM THEY OPEN INTO A B C
FLO�R C�VERING AND BASE AS REQUIRED F�R NEW ENTRY, �
PATCH WALL AS REQUIRED T❑ MATCH EXISTING, 10, ALL CONSTRUCTI�N SHALL BE I� GOOD CONSTRUCTI�N PRACTICE� * COORDINATE ALL FINISHES w� OWNER PLY' WD PLATF'❑RM w/ 2x4 STUD FRAME VER I FY ALL NEW F I XTURE STYLES & n
B) REM�VE EXISTING BENCH, PATCH WALL AS REQUIRED T❑ 11. ALL PR�DUCTS USED SHALL BE INSTALLED AS PER MFGR'S INSTRUCTI�NS, * ALL FLOORS FINISHES AND BASE TO BE NEW - AR�UND DR�P IN TUB w/ TRAVERTINE COL�RS w/ ❑WNER, Nw
MATCH EXISTING, F I N I SH , VER I FY w/ OWNER, F+i
C) REL❑CATE EXISTING FRONT D�OR AS PER ❑WNERS REQUEST. MAINTAINE ALL VERIFY WITH OWNER HAND HELD B I DET w/ H❑T & COLD O
APPLICABLE FIRE C�DES, * ALL ExISTING WALLS, REMAINING, TO BE PATCHED AS REQ'D AND TEMP, GL, SHWR, ENCL. WATER BY W. C. VERIF�Y STYLE w/
�WNER t- ,
O ST�RAGE PAINTED - VERIFY COLOR & TEXTURE w/ OWNER M I CA VAN I TY w/ TRAVERT I NE TOP & v
6" BACKSPLASH w/ MIRROR ❑VER r�
A) REMOVE EXISTING CLOSET WALLS, DR�PPED CLG. CAS REQ'D) D❑❑R II FULL LENGHT T❑ CE I L I NG V 1
AND FRAME, FL��R COVERING AND BASE IN THIS AREA, I VER I FY C�L�R w/ ❑WNER �
AS REQUIRED F�R NEW P�WDER R�OM CDNFIGURATIC7N, <SEE FL��R I
PLAN) PATCH WALL AS REQUIRED T❑ MATCH EXISTING, I �
B) REMOVE EXISTING CONCRETE T�PPING AND � I � ('-�.,
PLYW�OD SUB-FL��RING AS REQUIRED FOR THE �❑CATIDN I ^
❑F NEW POWDER R�[JM FIXTURERS, VENT AND �
DRAIN �INES, CSEE FL��R PLAN AND RISER DIAGRAMS) - - � �
PATCH FLOOR T❑ MATCH EXISTING, @�
II I � MASTER BATH U�
O BATH #2 � �
A) REM❑VE EXISTING WALL AS INDICATED F�R NEW CLOSET C�NFIG„ MASTER BATH 4 4 5 �
+9'-0" CLG. 4" z� 2° 4' 8' —10"
F"LOQR C�VERING AND BASE IN THIS AREA, �
PATCH WALL AS REQUIRED TO MATCH EXISTING. (I II � �
B) REM�VE EXISTING LAV,, VANITY AND WATER CLOSET AND PREPARE 2 I 1 CLOSET '�' H
F'OR NEW FIXTURERS AS REQUIRED, 1 3 5 $ O7 II � �
C) REM❑VE EXISTING DO❑R AND FRAME ��R INSTALLATI�N OF l -'� � O
NEW D��R AND FRAME. CSEE FL❑❑R PLAN) I �/� � ��-9�-0" CLG ) Z= OO � ` � O
MASTER BEDRD�M �u ��./ 'y � � Q
D) REM�VE EXISTING CONCRETE T�PPING AND �
PLYW❑�D SUB-FLD❑RING AS REQUIRED F�R THE L�CATI�N MASTER BEDROOM rtc, - vERIFY SHLVS, �
❑F' NEW P�WDER RDOM AND NEW LAUNDRY FIXTURE VENT AND �� STYLE w/ OWNER 36' HI TRAVERTINE �
DRAIN LINES, CSEE �L❑OR PLAN AND RISER DIAGRAMS> . 1 3 5 8 4" 18" WAINSC�AT �1
PATCH FLODR T❑ MATCH EXISTING, �� O , ��
�
� (VAULTED CLG ) O Q � �
O BEDRO�M #2 O
r A) REMOVE EXISTING D��RS, FRAMES AND WALL AS REQUIRED �ALC, BALC� • • � r ,
� - -- - - - -F"L�P INSTALLATI�N �F NEW DD�RS, PATCH WALL AS BEDROOM Z � � v
, REQUIRED T❑ MATCH EXISTING, `
r, B) PR�VIDE �PPENING IN EXISTING WALL AS REQ'D F�R THE ' � � 3 4 7 O O ^
INSTALLATIDN ❑F THE NEW 150 AMP, ELEC, PANEL AND MAIN SERVICE. STAIR STAIR � �
CSEE ELEC, PLAN) PATCH WALL T❑ MATCH EXISTING, � (VAULTED CLG ) � � H
� FDYER DN � DN � d- �
� KITCHEN
� 6 � BATH 2 6 �I FOYER C� W �
A) REM❑VE ALL BASE ANMD UPPER CABINETS, APPLIANCES, (I Z 2 7 � II � O �
PLUMBING FIXTURES, FLO�R COVERING AND BASE IN THIS AREA,
9 3 5 5
PATCH WALL AS REQUIRED T❑ MATCH EXISTING, � /-}-9�-0�� CLG.1 �� H ^
BEDRD�M #2 PR�VIDE 'L_AZY SUSAN" ` / �i VAULTED CLG � H �
B) REMOVE EXISTING DR�FFED S[7F"F'IT AND LUMIN�US CEILING AND I N BASE CAB I NET MICA VANITY Wi �N Q� O H O
LIGHT FIXTURES, AND PR�VIDE ❑PENINGS AS REQ'D FOR L�CATI�N 6• BACKSPLASH w/ MIRROR �VER � � �
❑F NEW RECESSED F'IXTURES CSEE ELEC, PLAN), PATCH CEILING T❑ FULL LENGHT TO CEILING
MATCH EXISTING, �}}
B A T H 7T� EX I ST I NG VERIFY COLOR w/ ❑WNER
O LIVING/DINING RDOM 125 AMP, � O PA EL50 AMP O H �
ELEC, PANEL_ MCSHELVE IFY ELEC � H
STYLE w/ ❑WNER STACKED WASHER/ �
A) REM�VE EXISTING WALL, PKT, D�OR AND FRAME AS INDICATED, 3 • DRYER - VENT r, �f,
FL��R C�VERING AND BASE AS REQUIRED FOR NEW BEDR��M #3 PR�VIDE C�PPER WATER O AS PER CODE w ^ �"� O
CONFIGURATION CSEE FL❑�R PLAN)
PATCH WALL AS REQUIRED T❑ MATCH EXISTING, ��--- ��� I �/;� S T Cl R� / E N T R Y L I NE F�R I CE MAKER �� � 4 � LAU N DRY � � �
B) REMOVE EXISTING C�NCRETE TOPPING AND — � N REF. ��� � 4" 2' -9" 9 3 5 5
PLYWOIJD SUB-FLO�RING AS REQUIRED F�R THE RE-L�CATI�N � —� � � N Z
��T�bEF'L���B�BR�AM��T�{'pS��+1G NEW WALL - SEE FL�OR PLAN, IC � S � � RANGE & OVEN w/ O � � O �-I-9�-O" CLG � W �
KITCHEN �I DUCTLESS MICROWAVE � Mc� - VERIFY ca o
C) REMOVE EXISTING M�SS ROCK FINISH AND HEARTH AT EXISTING 7 STYLE w/ OWNER �,
FIREPLACE� REPLACE w/ GYPBOARD T❑ MATCH EXISTING WALLS� � � II AB�VE 2' -8" DOUBLE � 1� (2) 2x12 HEADER o �
SINK w/ @ CLG HT� WRAPPED �+
D) REMOVE EXISTING C�NCRETE T�PPING AND _� — -• M I N. DISP. w/ WOOD T❑ MATCH , W �
PLYW�OD SUB-FLODRING AS REQUIRED F"�R THE L�CATION — N I � �v. R"+ c�� ►-
❑F NEW LAUNDRY FIXTURE'S VE�1T AND _ � — � I \� I I � I DW I /� Z � ^
DRAIN LINES, <SEE FL�OR PLAN AND RISER DIAGRAMS> _� _ �1 � a� ` , , �,,.� N ^
PATCH FL�OR T❑ MATCH EXISTING, o
E) REM�VE EXISTING CONCRETE T�PPING AND � 9 � � y�a �
PLYWDOD SUB-FL�QRING AS REQUIRED F�R THE L�CATION t6' -9' • Fi�� iN WALL T❑ MIRROR (- � �
( 4 CO TEMP, GL, SHWR. MATCH EXISTING BASE TO V �
❑F' NEW 150 AMP. ELECTRICAL SERVICE AS REQ'D, w y
<SEE ELEC. PLAN> PATCH FL�OR T❑ MATCH EXISTING� ENCLOSURE M,C, - VERIFY � O c��' � � �
VERIFY ALL NEW STYLE w/ OWNER C-
I � � KITCHEN FIXTURE STYLES & VINYL ~"� W ,r
O BATH #3 — _ __ — COLORS w/ OWNER POWDER ROOM SHELVING _ � U = �
O U �
A) REM�VE EXISTING WALLS, DODR AND FRAME AS INDICATED, � 9 9 4 7 9 3 5 5 ¢ Q ¢ d
F L❑O R C�V E R I N G A N D B A S E A S R E Q U I R E D F O R N E W B A T H #3 8 I � �-f-9'-O�� C L G.� �-1-9�-0'� C L G ) -1 � �"
C❑NFIG UR AT I�N C S E E F L��R P L A N> - I'I I'' 4 ` U 7 S �
PATCH WALL AS REQUIf2ED T� MATCH EXISTING, II \� W W --- 3' � ° ,
MICA VANITY w/
LI V I N G/D I N I N G P.0 0 M I 6' BACKSPLASH w/ MIRROR ❑VER �G�� Q °d
B) REM❑VE EXISTING LAV„ VANITY AND WATER CL�SET AND PREPARE DEMOLITI�N PLAN/ FULL LENGHT T❑ CEILING '�`
� 10 FLDOR PLAN LIVING DINING RO�M VERIFY COLOR w/ ❑WNER BATH 3 ENCLOSURE
F"OR NEW FIXTURERS AS REQUIRED, TEMP. GL, SHWR,
lo BEDRD❑M #3 BATH #3 SYMB�LS 9 9 4 7 2 2 � '
� (VAULTED CL(� � EXISTING fIREPLACE T❑ REMAIN , �-{-9'—O�� CLG ) '
A> REMOVE EXISTING WALLS, DO�RS AND FRAMES AS INDICATED, as Is
FL❑�R C�VERING AND BASE AS REQUIRED F�R NEW BEDROOM #3 � �
, � EXISTING TO REMAIN , T n of Va11 Commun�ry DESIGNED BY,
C�NFIGURATI�N CSEE Fl.O�R PLAN) NEW HEARTH <MIN DIM�s> VER I FY ALL NEW Oevela ment
PATCH WALL AS REQUIRED T❑ MATCH EXISTING, co VERIFY FINISH w/ OWNER � p
+i __ +i F I XTURE STYLES & DRAWN BY.
7 EXISTING T❑ BE REM�VED
-- " " CoLORS w� ❑WNER, Plan Heatth Flre �,
I � '�,.(!
�� EXISIING DOOR TO BE REMOVED � 4ppfOV2d ❑ ❑ � CHECKED BY. �� '*a
BEDR��M #3 � 1 �
- -- O�n�ed ❑ ❑ � L, JOB #. 92209
, NEW 4' INTERIDR PARTITI�N BEDROOM .3
alidEty of Per�mt DATE 04/14/92
1 3 5 8 5 3�� (u) 1a U C� C
BALCEXISTING DOOR TO REMAIN (VAULTED CLG ) r?,; �ssuance or gra ng of a �utmit ar a�iproe��l ot ptans a Sheet:
� B A L C� s�:acrftcatians shsll r, �e c.onstri�ed to �ae a pe�r�it inr, or
ry ��y of ihe provisio�ts ofi th�s co
�� e �ur�sdieation. The issuan�e � �� �
� d �erm�t basetl upon plans, spec9f►cations and other data sh I �� �� ' �
° --- ---�---- J n�= prevent the bu►Id�ng offfc�al from thereaftEr requirmg t a
� Q NEw DD�R — SEE DDOR SCH, c�rr�ction of errors in said plans, spec�fications and Oth
y data "
. v � EM � � ITIDN P � aN F� � ❑ ClR P � AN ��ATE: �-2�-� �- - ��,
SCALE� 1/4' = 1'-0' i� DEM�LITI�N N�TE � _ �_ � 1 0 f�
O SEE LIST THIS SHT. SCALE� i/4 - 1 0 '
, 1 �
� - - -- — � � - - - - --- __ _______�___________ _____. - . __ _____ _ ,.�.,_ .��._
.
_i . �
^ / � �11�.
REVISIONS BY
�_`�" C.� rJT- / \v�-1��- � �'��' � � _ I -ro
� v� � �� v��` -r,� �
• �� ��.�"I�o �3ClST+-Go �T�r: �V.tr � � �Ct�I-I�C,� Y�►.»"-T�t-�-tl 1�t"
r,�--t ----� Zt�
�� ��� �
3�i 1 � t-�,t, '
Gii
3"c� 2���
n
'fi� }1?�V 3`� r� t-1�1L �' Y
� ' f+kTo �}ST��� 3�'c� ��{�i�"i�vc. Zt��
- 2'� l►�t° �sr�
�`� \v��` �, � �
��rV�'�12- �t�f 1 l.�-�,�.�1��..`1* �'iA�-�"�� �T� _� \
_�
�
� �
P � UMBIN � �' ISER DIAGRAMS
.
N❑ SCALE ^
NEW TUH AND SHOWER - RELOCATE �
EXISTING DRAIN AS REQ'D O
(I V
i
i � ,' � ,
�
� 2' Jd" VENT UP - I �
(I LOOP INT� EXISTING w
VENT IN MASTER BATH �
i•I I _�
�,�; � 3 � �
I �V _� �,�� �
II II EXTEND EXISTING -
3' �" LINE T❑ NEW �
LAV WqTER CL�SET W� �
��"Ti � LOCATtON
�F�-�'�Ut.��.t'"�' � �
2' �' DRAIN LINE - TIE ��
�� INT❑ EXISTING 3',Pl ��
� WETSTACK DOWN �� O
� O M'�
' � �
Fr �
� �
� Q o
�� STAIR STAIR � p
�f�t , , �
�^ - -` - - - - — - -- - - I ,I�+Tt' �P D N I D N �j ('1� �/
� � p O �
�� ��
w � � H
PR�V I DE COPPER WATER 2' A�VENT UP ,�j � r, �
' �..lD�,,, L I NE F�R I CE MAKER N�w VENT @ POWDER RM � w �
0 �
(���T ELEC 150 AMP, TTE NEW 3',0' EL C 150 AMP. H •
��W F= PANEL LINE INT❑ EXfSTING PANEL � � �
(�(,�}.}'�'� 3' �" WETSTACK if� � �---I O
`L� �
PROVIDE C❑PPER WATER � � t�
LINE F�R ICE MAKER _ __ �� � _ _ _�� � O � � �
�� � � � � �
REF, REF. � � �
w � � o
RANGE & �VEN w/ � � � O �G}}A��- � Q 3� � STACKED WASHER/ � � � E"'�
DUCTLESS MICROWAVE � � DRYER - OUTLET BOX
ABOVE � DDUBLE O � DDUBLE Q 2' ,� �_
SINK
Q , DISP� SINK w/ 2' f�" LO�P VENT
• � DISP, AB�VE Z
t�6 c'� t7 �
Q I D W I I r (1�� C.'TVI�.. � ' p w I I W �
N
�-�-VP � Q
I
.L1 L - �-° — t �- - -1- — — —— o �
�� o
� 2' ,0' VENT L�OP 2' f! VENT UP ' I � � �
INTO EXISTING LO�P INT❑ \ /
�'�� VENT AT BATH #2 EXISTING VENT AT BATH #2 �—J V ~ �
�'� }l � x ��` EXTEND EX2STING Z � �
�/� �v 2' ,0' SINK DRAIN LIN S H N
AS REQ'D f�R NEW 3NK 'Z � J
�Mii"IF�2/ TD ���' N���I M��� �Q.1�t�� LOCATION - SLOPE MN 1/4' PER FT, (/) ¢ � �� �
J
(�I�.t1►k� �, Ft��� . . _ V W �
W � �
� ~ ~
_ � m
� � � �
� ¢ ¢ �
� �
� m
' DESIGNED BY
DRAWN BY�
CHECKED BY
JOB #• 92209
DATE. 04/14/92
-�--�---� S he e t:
c a L*.a�5.� +"'.a-�y, !R3'^ c'�''1.� �Rt, '� �i�
�� 4t
,r �a v.,,,�� F�X '�tis xy � v, .� � � r��
E � ECTRICA � F� � ❑ OR P � AN P � UMBING F� � � � R P � AN �Y;� �� � � � w+� ���� �� �
� SCALE� 1/4' = 1'-0' SCALE� 1/4' = 1'-0'
¢ ,� �t�i�1��: U iy �'��t i ! �
' N�TE� N❑TE�
i CONTRACT❑R T� PROVIDE AS-BUILT DRAWING UPON C❑MPLETI�N, C❑NTRACTOR T❑ PROVIDE AS-BULT DRAWING UP❑N C�MPLETI�N, J 2 2 Of: 2
�Y----- - --.. ._.___._...-•- ----DAT�.1.�.2�!:�..._
/
�
r 4 �,