Loading...
HomeMy WebLinkAboutDRB110480 FORTH PERMIT 8-11-11DN DN REF. 1 A4 . 1 2 A4 . 1 3 A4 . 1 10 " RE M O V E E X I S T I N G DE C K I N G . N E W L I V I N G RO O M F L O O R F I N I S H O N 3/ 4 " S U B F L O O R O N EX I S T I N G D E C K J O I S T A T PO R T I O N O F E X T E N D E D RO O M . P R O V I D E U N D E R FR A M I N G A N D M I N . R - 3 8 BL O W N - I N I N S U L A T I O N I N FL O O R . RE M O V E E X I S T I N G WI N D O W A N D F R A M E WA L L F O R N E W W I N D O W (E G R E S S ) NE W R O O F T O B E C O N S T R U C T E D TO O V E R L A P E X I S T I N G S T O N E PI E R / C O L U M N . R E M O V E E X I S T I N G DR Y E R V E N T A N D E X T E N D S T O N E TO T H E U N D E R S I D E O F N E W R O O F ST R U C T U R E . EX I S T I N G R O O F O N S C I S S O R T R U S S E S I S T O BE R E M O V E D . N E W R O O F T O B E R E F A M E D AT T H E E X I S T I N G R I D G E H E I G H T . N E W R O O F RA F T E R S A R E T O B E 1 4 " I - J O I S T S W I T H R - 5 6 BL O W N - I N I N S U L A T I O N 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number DateREVISIONS 8/11/2011 10:08:32 AM 1159 Sandstone Drive, Vail, CO Lot 5, Block 1, Lion's Ridge Filing 4 A0.0 COVER SHEET0408Richard Forth Residence Permit Set 8-11-11Renovation and Addition Ri c h a r d F o r t h R e s i d e n c e Re n o v a t i o n a n d A d d i t i o n 11 5 9 S A N D S T O N E D R I V E VA I L , C O L O R A D O No.DescriptionDateGRFA ALLOWED Single-family residential 0.40 of site area 10,000 sq. ft., plus= 4,000 SQ.FT.0.13 of site area > 10,000 sq. ft.(11,736)= 1,526 SQ. FT.TOTAL ALLOWED= 5,526 SQ. FT.EXISTING GRFA= 3,944 SQ. FT.TOTAL PROPOSED GRFA= 104 SQ. FT.PROJECT TOTAL PROPOSED=4,048 SQ. FT.LOT AREA = .499 ACRES x 43,560 SQ. FT. = 21,736.44 SQ. FT.SITE COVERAGE ALLOWED (20% OF SITE) = 4,347 SQ. FT.SITE COVERAGE EXISTING= 2,309 SQ. FT.SITE COVERAGE PROPOSED = 2,369 SQ. FT (60 SQ. FT.ADDED)LANDSCAPE AREA (60% OF SITE) =13,042 SQ. FT.EXISTING DRIVE AREA= 1,673 SQ.FT.EXISTING PATIO AREA= 262 SQ. FT.EXISTING BUILDING FOOTPRINT= 2,096 SQ. FT.= 4,031 SQ. FT.EXISTING LANDSCAPE AREA (UNCHANGED)21,736 SQ. FT. - 4,031 SQ. FT. = 17,705 SQ. FT. TOTAL LANDSCAPE (81.5%)TOWN OF VAIL ZONING DISTRICT:Single-FamilyZONING SUMMARY (SEE SHEET A0.1 FOR CALCS)HEIGHT LIMIT = 33'-0"HEIGHT EXISTING = (NO REVISION TO HEIGHT PROPOSED AT RIDGES)NEW DORMER PROPOSED HT ABOVE DRIVE= 29'-0"PARKING SPACES REQUIRED: 2 SPACES PARKING SPACES EXISTING: 2 SPACESSITE DISTURBANCE ALLOWED (60% OF SITE) = 13,042 SQ. FT.SITE DISTURBANCE ADDITIONAL PROPOSEDNONE Single Family Residence Owner: Richard Forth 100 Park Ave. W1501 Denver, Colorado 80205 Location: 1159 Sandstone Drive, Vail, CO 81657 Lot 5, Block 1, Lion's Ridge Filing 4 Parcel #2103-014-15-016PROJECT / CODE SUMMARY Class of Work: Renovation and Addition Type of Construction: Type V-N Type of Occupancy: R3 (single family)Levels: 2-story +basement Architect: Martin Manley Architects Agent: John G. Martin Architect PO Box 1587 Eagle, Colorado 81631 Phone: 970-328-0592 Fax:970-328-1273 E-mail:john@martinmanleyarchitects.com Contractor: Gillette llc PO Box 5821 Vail, CO 81658 970-390-7981VICINITY MAP 1 / 4 " = 1 ' - 0 " 1 02 M a i n L e v e l - D E M O RO O F W I L L B E E X T E N D E D T O C O V E R E X I S T I N G PI E R / C O L U M N . D R Y E R V E N T T O B E D E L E T E D . A S M A L L E R , NE W W I N D O W S W I L L B E I N S T A L L E D I N T H E E X I S T I N G OP E N I N G T O C O R R E C T R O O F W I N D O W I N T E R F A C E W E S T L I V I N G R O O M W A L L A N D R O O F W I L L BE C O N S T R U C T E D T O MA K E A SY M M E T R I C A L L Y EL E V A T I O N O N T H E RO O F A N D W I N D O W DE C K H A L F W A L L W I L L B E R E M O V E D A N D A N E W R A I L I N G M A T C H I N G T H E E X I S T I N G SH A L L B E I N S T A L L E D . A T I N T E R F A C E I F W A L L A N D L I V I N G R O O M R O O F , A 6 " C U R B SH A L L R E M A I N . T H I S W I L L F L A S H T O TH E E X I S T I N G R O O F A N D B E C A P P E D W I T H A M E T A L C A P F L A S H I N G . EX T E R I O R C O L O R S RO O F I N G : A S P H A L T S H I N G L E S , P R E S I D E N T I A L S H A K E , T L ( T R I P L E L A M I N A T E ) CO L O R : W E A T H E R E D W O O D FL A S H I N G A N D D R I P E D G E S : CO L O R : M A T C H E X I S T I N G CE M E N T S T U C C O S Y S T E M : CO L O R A N D T E X T U R E : M A T C H EX I S T I N G RA I L I N G : MA T C H E X I S T I N G S T Y L E , PR O F I L E A N D C O L O R TI M B E R A N D W O O D F A S C I A : CO L O R A N D T E X T U R E : M A T C H EX I S T I N G WI N D O W : MA T C H E X I S T I N G C O L O R ST O N E V E N E E R : MA T C H E X I S T I N G R I V E R R O C K INSULATION VALUES NEW ROOF STRUCTURE INSULATION = R-56 BLOWN-IN (14")NEW WALL CONSTRUCTION INSULATION = R-23 BLOWN-IN (5 1/2")NEW FLOOR AT LIVING RM CANTILEVER INSULATION = R-38 BLOWN-IN NEW WINDOW AND PATIO DOOR = U-VALUE OF 0.30 MIN.Drawing List Sheet NumberSheet Name A0.0COVER SHEET A0.1GRFA CALCULATIONS A2.1LOWER AND MAIN LEVEL PLANS A2.2ROOF AND UPPER LEVEL PLAN A3.1EXTERIOR ELEVATIONS A4.1BUILDING SECTIONS C1ILC SURVEY Grand total: 74spacesrequired4+spacesexistingCORRECTEDPLANS: RECEIVED BYTOWN OFVAIL8/11/11 DN DNREF.600 SFEXISTING GARAGE ALLOWANCE AREA 1496 SFEXISTING LOWER LEVEL AREA.2205 SFEXISTING MAIN LEVEL AREA OVER 5'-0" HT 45 SFADDITIONAL GRFA AT MASTER 60 SFADDITIONAL GRFA AT LIVING ROOM25 SFArea UNDER 5' 34 S F Ar e a U N D E R 5 ' 920 SFEXISTING UPPER LEVEL AREA 185 SFEXISTING AREA OVER-16'9' - 6" 01 L o w e r L e v e l 0" W A L L S U R F A C E A R E A = 8 4 3 S . F . EX P O S E D S U R F A C E = 8 4 3 S . F . UN E X P O S E D S U R F A C E = 0 S . F . 9' - 6 " 16' - 0" 01 . 9 M a s t e r L e v e l 12 ' - 8 " 02 M a i n L e v e l 13 ' - 8 " 01 L o w e r L e v e l 0" 03 U p p e r L e v e l 23 ' - 8 " W A L L S U R F A C E A R E A = 6 1 0 S . F . EX P O S E D S U R F A C E = 2 4 9 S . F . UN E X P O S E D S U R F A C E = 3 6 1 S . F . 02 M a i n L e v e l 13 ' - 8 " 01 L o w e r L e v e l 0" 03 U p p e r L e v e l 23 ' - 8 " W A L L S U R F A C E A R E A = 4 6 8 S . F . EX P O S E D S U R F A C E = 0 S . F . UN E X P O S E D S U R F A C E = 4 6 8 S . F . 01 . 9 M a s t e r L e v e l 12 ' - 8 " 02 M a i n L e v e l 13 ' - 8 " 01 L o w e r L e v e l 0" W A L L S U R F A C E A R E A = 6 3 4 S . F . EX P O S E D S U R F A C E = 3 8 1 S . F . UN E X P O S E D S U R F A C E = 2 5 3 S . F . 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number DateREVISIONS 8/11/2011 10:09:41 AM 1159 Sandstone Drive, Vail, CO Lot 5, Block 1, Lion's Ridge Filing 4 A0.1 GRFACALCULATIONS0408Richard Forth Residence Permit Set 8-11-11Renovation and AdditionNo.DescriptionDate 1/8" = 1'-0"101 Lower Level 1/8" = 1'-0"202 Main Level 1/8" = 1'-0"303 Upper Level 1 / 8 " = 1 ' - 0 " 4 GR F A E L E V A T I O N - F R O N T 1 / 8 " = 1 ' - 0 " 5 GR F A E L E V A T I O N - E A S T 1 / 8 " = 1 ' - 0 " 6 GR F A E L E V A T I O N - B A C K 1 / 8 " = 1 ' - 0 " 7 GR F A E L E V A T I O N - W E S T GR F A C A L C U L A T I O N S : (T O W N O F V A I L O R D I N A N C E N O . 1 4 S E R I E S 2 0 0 4 ) BA S E M E N T P E R C E N T A G E C A L C U L A T I O N S : TO T A L W A L L S U R F A C E = 2 , 5 5 5 S Q . F T . TO T A L U N E X P O S E D W A L L S U R F A C E = 1 , 0 8 2 S Q . F T . PE R C E N T A G E O F U N E X P O S E D W A L L S U R F A C E = 4 2 % LO W E R L E V E L A R E A =2 , 0 9 6 S Q . F T . GA R A G E A L L O W A N C E -6 0 0 S Q . F T . TO T A L L O W E R L E V E L A R E A 1 , 4 9 6 S Q F T . AD J U S T E D L O W E R L E V E L 1 , 4 9 6 S Q . F T . x . 4 2 = 6 3 4 S . F . Ar e a S c h e d u l e ( E n t i r e B u i l d i n g ) Na m e A r e a L e v e l EX I S T I N G L O W E R L E V E L A D J U S T E D A R E A 6 3 4 S F 0 1 L o w e r L e v e l EX I S T I N G M A I N L E V E L A R E A O V E R 5 ' - 0 " H T 2 2 0 5 S F 0 2 M a i n L e v e l EX I S T I N G U P P E R L E V E L A R E A 9 2 0 S F 0 3 U p p e r L e v e l EX I S T I N G A R E A O V E R - 1 6 ' 1 8 5 S F 0 3 U p p e r L e v e l Gr a n d t o t a l : 4 3 9 4 4 S F Ar e a S c h e d u l e f o r a d d e d G R F A Na m e A r e a L e v e l AD D I T I O N A L G R F A A T M A S T E R 4 5 S F 0 2 M a i n L e v e l AD D I T I O N A L G R F A A T L I V I N G R O O M 6 0 S F 0 2 M a i n L e v e l Gr a n d t o t a l : 2 1 0 4 S F 8 Pe r s p e c t i v e o f D e m o l i t i o n 9 Pe r s p e c t i v e o f N e w C o n s t r u c t i o n DN DN REF. 1 A4 . 1 2 A4 . 1 3 A4 . 1 1 A4 . 1 13 ' - 5 " 3' - 6" 2 A4 . 1 10 1 10 2 10 3 10 4 3 A4 . 1 10 " 1" 3' - 5 " 3' - 7 1 / 2 " 5 1 / 2 " 12 ' - 6 " 4' - 0 " 3' - 6 1/2"1' - 0"4' - 0"3 1/2"3' - 10"6' - 4"3' - 10"5 1/2"3' - 9 1/2"1' - 0" 8' - 1" 5 1/2" 18' - 1"5 1/2" 10 5 7' - 0 1 / 2 " 5' - 2 1 / 4 " NE W F L O O R F I N I S H O N 3 / 4 " SU B F L O O R O N E X I S T I N G DE C K J O I S T A T P O R T I O N O F EX T E N D E D R O O M . P R O V I D E UN D E R F R A M I N G A N D M I N . R- 3 8 B L O W N - I N I N S U L A T I O N IN F L O O R . NE W 4 0 x 6 0 C A S E M E N T W I N D O W U- V A L U E = 0 . 3 0 M I N . RE U S E X I S T I N G P A T I O D O O R S . TR A N S O M S T O B E D I C A R D E D 1 10 8 NE W 1 0 ' - 0 W I D E x 8 ' - 0 " TA L L P A T I O D O O R W I T H CE N T E R P A I R O P E R A T I O N . U- V A L U E = 0 . 3 0 M I N . 6' - 3 " 6' - 3 " 1' - 0 " 7' - 0 1 / 2 " 5 1 / 2 " 28' - 1" 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number DateREVISIONS 8/11/2011 10:09:42 AM 1159 Sandstone Drive, Vail, CO Lot 5, Block 1, Lion's Ridge Filing 4 A2.1 LOWERANDMAINLEVELPLANS0408Richard Forth Residence Permit Set 8-11-11Renovation and Addition 1/4" = 1'-0"101 Lower LevelNo.DescriptionDate 1 / 4 " = 1 ' - 0 " 2 02 M a i n L e v e l Door Schedule Ma r k D e s c r i p t i o n W i d t h H e i g h t C o m m e n t s L e v e l 10 1 S i n g l e - S o l i d 2 ' - 6 " 7 ' - 0 " 0 2 M a i n L e v e l 10 2 S i n g l e - S o l i d 2 ' - 6 " 7 ' - 0 " 0 2 M a i n L e v e l 10 3 S l i d i n g P a t i o 6 ' - 0 " 8 ' - 0 " r e - u s e e x i s t 0 2 M a i n L e v e l 10 4 S i n g l e - S o l i d 2 ' - 6 " 7 ' - 0 " 0 1 . 9 M a s t e r L e v e l 10 5 S i n g l e - S o l i d 2 ' - 0 " 6 ' - 8 " 0 1 . 9 M a s t e r L e v e l 10 6 K o l b e U l t r a S e r i e s I n s w i n g H a n d i c a p S i l l 1 W i d e P a t i o D o o r 2' - 6"8' - 0"01.9 Master Level 10 7 K o l b e U l t r a S e r i e s I n s w i n g H a n d i c a p S i l l 1 W i d e P a t i o D o o r 2' - 6"8' - 0"01.9 Master Level 10 8 P a t i o - O u t - s w i n g 5 ' - 0 " 8 ' - 0 " 0 2 M a i n L e v e l Gr a n d t o t a l : 8 Window Schedule Ma r k D e s c r i p t i o n W i d t h H e i g h t Head HeightSill HeightLevelType Mark 1 3 ' - 4 " 4 ' - 1 1 1 / 8 " 8 ' - 0 " 3 ' - 0 7 / 8 " 0 2 M a i n L e v e l H H H Gr a n d t o t a l : 1 1 A4 . 1 2 A4 . 1 3 A4 . 1 DE C K H A L F W A L L W I L L B E R E M O V E D A N D A N E W R A I L I N G M A T C H I N G T H E E X I S T I N G SH A L L B E I N S T A L L E D . A T I N T E R F A C E I F WA L L A N D L I V I N G R O O M R O O F , A 6 " C U R B SH A L L R E M A I N . T H I S W I L L F L A S H T O TH E E X I S T I N G R O O F A N D B E C A P P E D WI T H A M E T A L C A P F L A S H I N G . 1 A4 . 1 2 A4 . 1 3 A4 . 1 WO O D S H A K E R O O F I N G I S T O B E R E M O V E D O V E R EN T I R E H O M E A N D N E W L A Y E R O F F U L L C O V E R A G E WA T E R P R O O F I N G M E M B R A N E I N S T A L L E D . N E W R O O F I S TO B E A S P H A L T S H I N G L E S , P R E S I D E N T I A L S H A K E , T L (T R I P L E L A M I N A T E ) RE P L A C E E X I S T I N G D R I P E D G E S A N D F L A S H I N G A S RE Q U I R E D . M A T C H E X I S T I N G C O L O R O F D R I P ED G E S / F L A S H I N G . NE W R O O F EX T E N S I O N / ST R U C T U R E NE W R O O F T O B E R E F A M E D A T T H E E X I S T I N G R I D G E H E I G H T . NE W R O O F R A F T E R S A R E T O B E 1 4 " I - J O I S T S W I T H R - 5 6 B L O W N - IN I N S U L A T I O N NE W D O R M E R 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number DateREVISIONS 8/11/2011 10:10:02 AM 1159 Sandstone Drive, Vail, CO Lot 5, Block 1, Lion's Ridge Filing 4 A2.2 ROOFANDUPPERLEVELPLAN0408Richard Forth Residence Permit Set 8-11-11Renovation and AdditionNo.DescriptionDate 1/4" = 1'-0"103 Upper Level 1 / 4 " = 1 ' - 0 " 2 04 R o o f P l a n 02 Main Level 13' - 8"01 Lower Level 0" 00 G A R A G E F L O O R -2 ' - 0 " 03 Upper Level 23' - 8" 1 A4 . 1 2 A4 . 1 01 . 9 M a s t e r L e v e l 12 ' - 8 " 3 A4 . 1 5' - 2 1 / 4 " DE C K H A L F W A L L W I L L B E R E M O V E D A N D A N E W R A I L I N G M A T C H I N G T H E E X I S T I N G SH A L L B E I N S T A L L E D . A T I N T E R F A C E I F WA L L A N D L I V I N G R O O M R O O F , A 6 " C U R B SH A L L R E M A I N . T H I S W I L L F L A S H T O TH E E X I S T I N G R O O F A N D B E C A P P E D WI T H A M E T A L C A P F L A S H I N G . EX I S T I N G R O O F O N S C I S S O R T R U S S E S I S T O B E RE M O V E D . N E W R O O F T O B E R E F A M E D A T T H E EX I S T I N G R I D G E H E I G H T . N E W R O O F R A F T E R S AR E T O B E 1 4 " I - J O I S T S W I T H R - 5 6 B L O W N - I N IN S U L A T I O N . F A S C I A A T N E W R O O F I S T O MA T C H T H E E X I S T I N G D E S I G N A N D M A T E R I A L NE W D O R M E R NE W F A S C I A T O MA T C H E X I S T I N G AT R O O F EX T E N S I O N NE W V E R T I A L T & G SI D I N G A T M A S T E R EL E M E N T . M A T C H EX I S T I N G S I Z E , TE X T U R E , A N D C O L O R OF O T H E R S I D I N G O N HO M E RO O F EX T E N S I O N . EX T E N D ST O N E T O UN D E R S I D E OF S O F F I T NE W 4 0 " X 6 0 " WI N D O W M I N . U - VA L U E = 0 . 3 0 Li v i n g R m Ex t e n s i o n NE W 1 0 x 1 6 T I M B E R UN D E R M A S T E R CA N T I L E V E R A N D BE D R O O M CA N T I L E V E R NE W 4 P A N E L D O O R 1 0 ' - 0 " x 8 ' - 0 " MI N . U - V A L U E = 0 . 3 0 28' - 11 3/4" AD D N E W T I M B E R S A T LI V I N G R O O M R A K E R O CL A D D E X I S T I N G T O MA T C H S I Z E O F N E W TI M B E R S 02 Main Level 13' - 8"01 Lower Level 0"13' - 8" 00 G A R A G E F L O O R -2' - 0"03 Upper Level 23' - 8"01.9 Master Level 12' - 8"RELOCATED EXISTING DOORS.EXISTING TRANSOM NOT TO BE USED WE S T L I V I N G R O O M W A L L A N D R O O F W I L L BE C O N S T R U C T E D T O MA K E A S Y M M E T R I C A L L Y EL E V A T I O N O N T H E RO O F A N D W I N D O W 02 M a i n L e v e l 13 ' - 8 " 01 L o w e r L e v e l 0" 00 G A R A G E F L O O R -2 ' - 0 " 03 U p p e r L e v e l 23 ' - 8 " 01 . 9 M a s t e r L e v e l 12 ' - 8 " 02 M a i n L e v e l 13 ' - 8 " 01 L o w e r L e v e l 0" 03 U p p e r L e v e l 23 ' - 8 " 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number DateREVISIONS 8/11/2011 10:10:55 AM 1159 Sandstone Drive, Vail, CO Lot 5, Block 1, Lion's Ridge Filing 4 A3.1 EXTERIORELEVATIONS0408Richard Forth Residence Permit Set 8-11-11Renovation and AdditionNo.DescriptionDate 1/4" = 1'-0"1ELEVATION - FRONT 1/4" = 1'-0"2ELEVATION -WEST 1 / 8 " = 1 ' - 0 " 3 EL E V A T I O N - B A C K 1 / 8 " = 1 ' - 0 " 4 EL E V A T I O N - E A S T WOOD SHAKE ROOFING IS TO BE REMOVED OVER ENTIRE HOME AND NEW LAYER OF FULL COVERAGE WATERPROOFING MEMBRANE INSTALLED. NEW ROOF IS TO BE ASPHALT SHINGLES, PRESIDENTIAL SHAKE, TL (TRIPLE LAMINATE)REPLACE EXISTING DRIP EDGES AND FLASHING AS REQUIRED. MATCH EXISTING COLOR OF DRIP EDGES/FLASHING. 02 Main Level 13' - 8"01 Lower Level 0"00 GARAGE FLOOR -2' - 0"03 Upper Level 23' - 8"4' - 0" 6' - 6" 6' - 0"01.9 Master Level 12' - 8"7' - 11 7/8"03 Upper Level 23' - 8"11' - 0"9' - 6"6' - 0 1/8"01.9 Master Level 12' - 8"RAILING PROFILE TO MATCH EXISTINGLINE OF EXISTING TRUSS BEING REMOVEDNEW ROOF TO BE REFAMED AT THE EXISTING RIDGE HEIGHT.NEW ROOF RAFTERS ARE TO BE 14" I-JOISTS WITH R-56 BLOWN-IN INSULATION NEW DORMER 7' - 6 3/4"TENSION CABLE - RE: STRUCT. DWGS. MA I N F L O O R L E V E L B E Y O N D EX I S T I N G F L O O R J O I S T S & R - 3 8 I N S U L A T I O N FASCIA DETAIL:MATCH EXISTING 01.9 Master Level 12' - 8"970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number DateREVISIONS 8/11/2011 10:11:10 AM 1159 Sandstone Drive, Vail, CO Lot 5, Block 1, Lion's Ridge Filing 4 A4.1 BUILDINGSECTIONS0408Richard Forth Residence Permit Set 8-11-11Renovation and AdditionNo.DescriptionDate 1/4" = 1'-0"1Section 1 1 / 4 " = 1 ' - 0 " 2 Se c t i o n 2 1 / 4 " = 1 ' - 0 " 3 Se c t i o n T h r u M a s t e r B a t h