Loading...
HomeMy WebLinkAboutB11-0280NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES �, ��• �� �� ��� Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0280 Job Address: 610 W LIONSHEAD CR VAIL Location......: LANDMARK UNIT 704 Parcel No....: 210106330075 OWNER CERO S.E. 08/18/2011 URB PUERTO NUEVO 322 AVE DE DIEGO STE 301 SAN JUAN PR 00920-2223 APPLICANT TNT RENOVATIONS LLC O8/18/2011 Phone: 970-471-3246 987 RUBY LN LEADVILLE CO 80461 License: 987-B CONTRACTOR TNT RENOVATIONS LLC 08/18/2011 Phone: 970-471-3246 987 RUBY LN LEADVILLE CO 80461 License: 987-B Description: INTERIOR REMODEL WITH MASTER BATH RECONFlGURATION. CHANGE FLOORING, COUNTERS, PLUMBING FIXTURES AND PAINT. ADD A/C UNIT AND INSTALL NEW APPLIANCES. Occupancy: R-2 Type Construction: ...................x„x........_...,..,..,..�....«.,..........,.,.,........,,,,�..,.,.. FEE SUMMARY ,.... Building Permit -----------> $776.75 Bldg Plan Check ----------> $504.89 Electrical Permit ---------> $172.50 Elec Plan Check -----------> $112.13 Mechanical Permit ------> $640.00 Mech Plan Check ---------> $160.00 Plumbing Permit --------> $60.00 Plmb Plan Check ---------> $15.00 Project #: Applied.....: Issued. . . : PRJ 11-0456 08/18l2011 10/03/2011 Valuation: $69,000.00 Use Tax Fee-----------------------> $1,180.00 Restuarant Plan Review--------> $0.00 Additional Fees--------------------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 TOTAL PERMIT FEES-------------> $3,641.27 Payments------------------------------> $3,641.27 BALANCE DUE-----------------------> $0.00 .,..,....�.....� ..................,....>....,......�.........�................................x......................�..............+............,�...,...�.....*..��:.....�........_.. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:OOAM- OOP � � � � l� `1 1 � Signature of Owner or Contractor Dat �nJ `(�i1� f} ✓�.�. '� �'l.�%�N��%L— Print Name combination permit_012811 3 � TiI�V�V OF VAI� . ....,,x .........................................................................................................................................................x,..,................ CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: 611-0280 Address: 610 W LIONSHEAD CR VAIL Owner: CERO S.E. Location: LANDMARK UNIT 704 ........................................................x,....,...................,,,...............................,.....,,�......,..........>.....�.......,........,...........,... Cond: CON0012117 Sprinkler system reconfiguration required in drop ceiling areas to accomodate mechanical equipment proposed. combination permit_012811 . ._ : - � ! V�1iM V� i��' . ***«*„*.**«.,.,**.***«*******.,**««..,*********.*********«********.,*«********««,..,***«**.,«„**************«*******.*******«******,.**«*******«*******.,****** Permit #: B11-0280 Owner: CERO S.E. UNIT 704 REQUIRED INSPECTIONS AND STATUSES Address: 610 W LIONSHEAD CR VAIL Location: LANDMARK ******�****�***,,.,.****.,,***********«««*«****************,,,,..***************«***************************„*****«********«*,.****«**,*************„**.,*** Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00070 BLDG-Misc. Item: 00120 ELEC-Rough Item: 00190 ELEC-Final Item: 00200 MECH-Rough Item: 00220 PLMB-Rough/D.W.V. Item: 00230 PLMB-Rough/Water Item: 00240 PLMB-Gas Piping Item: 00290 PLMB-Final Item: 00310 MECH-Heating Item: 00315 PLMB-Gas Piping Item: 00320 MECH-Exhaust Hoods Item: 00330 MECH-Supply Air Item: 00340 MECH-Misc. Item: 00390 MECH-Final Item: 00542 PLAN-FINAL Item: 00090 BLDG-Final combination permit_012811 *******************************************�*****************************************+****** TOWN OF VAIL, COLORADO Statement **********�*******�************************�*******************+**************************** Statement Number: R110001379 Amount: $3,386.96 10/03/201102:34 PM Payment Method: Check Init: SAB Notation: 1295 - TNT RENOVATIONS ----------------------------------------------------------------------------- Permit No: B11-0280 Type: COMBINATION BLDG PERMIT Parcel No: 2101-063-3007-5 Site Address: 610 W LIONSHEAD CR VAIL Location: LANDMARK UNIT 704 Total Fees: $3,641.27 This Payment: $3,386.96 Total ALL Pmts: $3,641.27 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code BP 00100003111100 EP 00100003111100 MP 00100003111100 PF 00100003112300 PP 00100003111100 UT 11000003106000 WC 00100003112800 Description BUILDING PERMIT FEES ELECTRICAL PERMIT FEES MECHANICAL PERMIT FEES PLAN CHECK FEES PLUMBING PERMIT FEES USE TAX 4°s WILL CALL INSPECTION FEE Current Pmts 776.75 172.50 640.00 537.71 60.00 1,180.00 20.00 ----------------------------------------------------------------------------- %2 � i-. "_ a. �.�n___.:1�-�_.._"M......1.'.... 75 South Fr.ontage -i=. � - Vaii, C�.lorado::t .:,�r y, . :( � • ' ..:��el _9��-�79 , r . _ Fa3c�-;:97yQ ���9 TRANSMITTAL FORM Revision Submittals: 1. "Fieid Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved 8� the permit is re-issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: �( � -t��8 �o Project Street Address: Attention: ( ) Revisions (c.�� sponse to Correction Letter � L. �[�' c/attached copy of correction letter ( ) Deferred Submittal ( ) Other (Number) (Street) (Suite #) Building/Complex Name: 1 -+'lNal'�'(�'G ��L, Contact Information: Company: ��1�7T PGINc�J ��/� S �� L Company Address: ��� �w� �7 City: (. �� l.(�G State: �.� Zip: b �y, �o � Contact Name: �(��� ��^t,��v'2- Contact Phone: C( � c) �-l1 l'�a�-{ b E-Mail �,n} �r�U�C��c)!�Slv , nC.� Revised ADDITIONAL Valuations (Labor 8� Materials) (DO NOT include original valuation) Building: Plumbing: Electrical: Mechanical: Total: $ � $ $ $ $ Description / List of Changes: �' � � Gi�-S v �uqp� � �.�J � S2t�'� � � l� C.�v�-C� C�c.. C�Gv�C�C. �✓�- /'t //: l.� ,r, .� ��.n� G � .r�a.�7,1� �l�VY�.✓l :�� � `� � Gr�� �•�e c� s T �� Q � �� J- �o.-u-e.- 4i✓�C,�!�.cl.�J G S UC� � � � ��JSP�T �� v��� � �O � ��� � 1�,r e.\ � �-� € � �l` �� ` 3 ! _- �Q fw� ��V. 1Y � L �. � � �\e�.�'rc:�..� 1 � w � ��-e � �� I� 1 l s �.�,� —ca.i I(use additional sheet if necessary) Date Received: � � � Q �/� � D" SEP 2 0 2011 OF VAI L O1-Jan-10 � �� TNT Renovations LLC Date: 9/15/2011 Re: 610 W Lionshead Cr Unit 704 Dear Mr. Haeberle We have reviewed the building comments in your 8/31/2011 letter regarding the above referenced project and have generated the following responses. Your initial comments are included. BUILDING COMMENTS Architectural Comments Sheet A2.1 9. Plans to reflecf building type, occupancy classification, and applicable codes. See Town of Vail submittal requirements. No changes to exisCing building construction type or occupancy classification are anticipated with the remodel scope of work. The 2009 International Code Family, with Town of Vail Amendments, and the Z008 National Electrical Code, with Town of Vail Amendments are the codes app/icable to the project. 2. Plans fo be sealed by a licensed architect if penetrating fire assemblies with mechanical equipment Please provide cross-sectiona/ details for proposed installafions. Please see r•evised HVAC plans. New duct penetrations of�re rated assemblies are not anticipated. 3/ "Piping penetrations of assemblies is anticipated at exterior to enter unit and interior walls to supply air handler surface mounted units. One small sof�'tt is purposed within existing frre assemblies for living and dining s�aace. 3. Provide flame spreads classification for the proposed flooring showing compliance for the building type. Reference section 603 IBC Proposed flooring- rated clnss 2. Thermal resistance ISO �30Z �.�5 �-U.Ob 1 m2 K/W Fire classif►cation EN ISO 9239-1 C fl...BS476.7 class 2. Please see attached data sheet. 4. Obtain a DRB approval for the HVAC and decking materials prior to resubmittal. Please see attached DRB approval for H6'AC. Decki►ag l�as been omitted from the job Scope of Work. Sheet A2.4 1. Show on plans the ceiling height of all spaces. Reference Town of Vail submittal requirements. Please see att��clled �fcrn with ce�lilig heights. Mechanical Comments: Sheet M-1 1. Provide a minimum 20 x 30 access for each air handler. Reference section 306.31MC All but one of purposed units are surfaced mount configuration. A pane120x30 will be provided and large enough to remove the largest piece of equipment as required by section 306.3 2. Plans do not reflect the required condensafe drains per section 307 of the IMC. Revise plans. Please see revised planstor proposed condensate drainage strategies. Electrical Comments: 1. Provide complete electrical plans for review. See Town of Vail submittal requirements. Please see attached electrical plans a�1d load calculatior�s. PLANNING COMMENTS DRB approval required prior to resubmittal. aRR c�����r�u�rcrt rr�� ludecl i�i r�et�� r°ei�isei� sii[�n�it�tnl. FIRE COMMENTS Reviewed and accepted PUB�IC WORKS COMMENTS NA Thank you for your consideration and review. Sincerely, Todd Turner TNT Renovations LLC. Tn��in ni \/�il ponc7 � � � DATA SHEET Harmonics Skyline Maple & Harvest Oak Laminate Flooring SKU#: 239-539 & 239-549 Flooring Available Exclusively Through Costco Version 1/2/08 Method Parameters Norm Requirements Sky Maple & Harvest OakValues Technical data Plank Thickness Total gmm Foam Thickness Thickness Zmm Plank dimensions 10mm 6-1/8" x 54-11/32" Planks per carton 9 planks Sq Ft per plank 2.32 SF Sq Ft per carton 20.86 SF Tongue & groove Uniclic License Underlayment (foam) type Cross-linked polyolefin Overall Performance Class (wear, EN 13329 class 21,22,23 impact, swell, stain, fade, burn, etc.) class 31,32 CE EN 14041 Notified body 0380-1161 Warranty Residential Only Details printed in each carton 35 years Wear resistance EN 13329 >=4000 >=4000 Wear class EN 13329 AC 4 AC 4 Moisture swellin EN 13329 after 24h immersion <= 18% <=8% General aspect of installed EN 13329 lipping <=0.15mm <=0.10mm flooring opening betw. Joints <=020mm <=0.10mm general fl atness length o��a�e<=oso% �o��ex<=, 00% concave<=0 50% �o��a,<=, oow general fl atness width oo��a��<=o is% �o <=o zow oncavec0 15% ca .<=oso% Brinell hardness NF B 51-126 mean hardness 6.7 Mpa Impact resistance bi ball EN 13329 IC 2 IC 2 Scratch resistance EN 438-2, 14 Charge >= 3.0 N B.ON Staining EN 438-2, 15 group 1,2 class 5 class 5 group 3 class 4 class 5 group 4 -------------- class 4 Light fastness EN 438-2, 16 Bleu reference class 6 > 6 Burning cigaret EN 438-2, 18 class 4 class 5 Displacement of furniture EN 424 foot 0.1 mm/32kg no change feet foot 3mm/100 kg no change foot 2mm/100 kg no change Castor chairs EN 425 25000 cycles Type W(EN 12529) no change Dimensional variations NF B 54 - 011 variation length AND width <=0.10% Formaldeh de emission EN 717-1 E1, <0.020ppm A-static EN 1815 charge human body <=2.OkV 23°C and 25% rel. Hum idity Slip resistance EN 13893 European Ramp Test DS ASTM C1028 Static Coefficient of Friction: Dry ADA Standard = 0.60 0.69 Sound reduction ASTM E90 & E492 Favored Levels >= 60 STC = 66 IIC = 68 Thermal resistance ISO 8302 0.051 - 0.061 m2°K/W Underfloor heatin on condit. of appropr. subfl oor Ask for specific information OK fire classification EN ISO 9239-1 Cn BS 476.7 class 2 DIN 4102.14 B� Rev: 6/25/08 HarmonicsTechnical Services Department • 1000 Cal Oak Road, Oroville, CA 95965 � Ph: (888) 459-9220 • Fax: (530) 534-0306 • Email: HarmonicsTechService@cal-flor. com � Job Name : Purchaser: Submitted To : Submitted By : Unit DesiQnation : Schedule No.: Capacities : Coolinq Capacitv Btu/h) 24,200 Power Input (W, Coolinq) 80 Heatinq Capacitv Btu/h) 27,300 Power Input (W, Heatinq) 80 Cooling Nominal Test Condition : Heating Nominal Test Condition : Indoor : 80.6�� DB / 662"P WB Indoor : 68'F DB / 59`F WB Outdoor 95r DB / 75.2"F WB Outdoor 44.6'r DB / 42.8'F WB Pipe Length : 25k per indoor unit Pipe Length �. 25ft per indoor unit Level Difference �. Oft Level Difference �. Oft Power Supply : Power Supplv (V,Ph,Hz) 230/208.1,60 Minimum Circuit Amqacity (A� 1.6 Maximum Overcurrent Protection (A) 15 Full Load Amps (A1 0.4 Fan : Fan Tyoe Sirocco Fan Quantitv 2 Fan Motor Output (IM 80 Air Flow Rate (CFM, H/M/L, Hiqh Static Mode) 600/530/355 External Static Pressure (inAq, Hiqh Static Mode) 0.08 Air Flow Rate (CFM, H/M/L, Standard Mode) 600/530/355 External Static Pressure (inAq, Standard Mode) 0 Drive BLDC Direct Refrigerant Piping : Refrigerant R410A Control Electronic Expansion Valve Liquid Side Pipinq (inches, O.D) 3/8 G S d P� � h O D) 5/8 RU Li v��- Location : Date : For : ❑ Reference ❑ A�proval ❑ Construction Model No.: 'L MULT/ �I /.. ��,,,� _ . � ��� '�: � _ `-��.-.•.<;a __— r' � �� r �i � ' __t— fi � �� I43 5/16 ,�� i With Suction Grille _, �� R • as i e iping (inc es, Drain Pipinq (inches, O.D, I.D) 1 1/4, 1 _ - Unit Data : � % -- With Suction Grille � Air Filter Mesh Type, Washable ,; ' 8 Suction Canvas Sound Pressure (d6(A), H/M/L Cool, 4.9ft center) 46/43/37 � Weiqht (Ibs) 57 Standard Features : • One Year Functional Parts Warranty • Built-in Drain Pump • ESP Control • Auto Changeover (available with Multi V Sync II) • Auto Restart • BLDC Fan Motor • Self Diagnosis • 24 Hour On/Off Timer, Weekly Timer • Group Control • Two Thermistor Control Accessory Option : • Wireless Remote Controller - PQWRHDFO (PQRCUSAO needed) • Standard Type Wired Remote Controller - PQRCUSAO • Simple Type Wired Remote Controller - PQRCUCAO • Simple for Hotel Type Wired Remote Controller - PQRCFCSO • Dry Contact without Case - PQDSA • Dry Contact with Case (1 Contact Point) - PQDSB • Dry Contact with Case (2 Contact Points) - PQDSBC • Suction Grille - PBSG640 • Suction Canvas - PBSC40 .` . . + \\� - � / . .__ � � �m � �� � �, � � . ., . � � . . .. _ . � o� 46 13/16 i 3/16 43 5/16 �� 11116 ^ w Suction Grille - PBSG640 Suction Canvas - PBSC40 �� 1�� Li uid Side Pi e Connection � Gas Side Pi e Connection �:.3; Drain Pi e Connection �` Power Su I Connection - Air Dischar e Su I NOte : tP AirSuction Return LG Elechonics Inc. HVAC Division ��'� LG Electronics USA 2008 SD-ARNU243B4G2-VER1 1000 Sylvan Avenue, Englewood Cliffs, NJ 07632 / www.lgusa.com www.lghvaacom Specifications and information in this submittal data are subject to change without notice. � �s� �t���;�� Job Name : Submitted To : Submitted By : Unit Desianation : Schedule No.: Capacities : Coolinq Capacity (Btu/h) 7,500 Power Input (W Coolinq) 40 Heatinq Capacitv (Btu/h) 8,500 Power Input (W Heatinq) 40 Cooling Nominal Test Condition . Heating Nominal Test Condition . Indoor 80 6 � DB I 662`P WB Indoor 68 T DB / 59`P WB Outdoor : 95'F DB / 752"� N!B Outdoor : 44.6'P DB / 42.8'F WB Pipe Length : 25ft per indoor unit Pipe Length : 25ft per indoor unit Level Difference �. Oft Level Difference : Oft Power Supply : Power Suqplv (V Ph,Hz) 230/208,1,60 Minimum Circuit Ampacitv (Al 1.3 Maximum Overcurrent Protection (A) 15 Full Load Amps (A) 0.2 Fan : Fan Tyqe Cross Flow Fan Quantitv 1 Fan Motor Output (1M 20 Air Flow Rate (CFM. H/M/U 265/230/210 Drive BLDC Direct Refrigerant Piping : Refrigerant R410A Control Electronic Expansion Valve Liquid Side Pipinq (inches O.D) 1/4 Gas Side Pipinq (inches, O.�) 1/2 Drain Pipinq (inches, O.D, I.D) 1 1/4, 1 Unit Data : Air Filter Mesh Type, Washable Sound Pressure (d6(A), H/M/L Cool, 4.9ft front) 40/38/37 Weipht (Ibs Unit) 25 Weight (Ibs, Front Panel PT-UMA) 3 Standard Features : • One Year Functional Parts Warranty • Built-in Drain Pump • ESP Control • Plasma Air Purifying System • Auto Changeover (available with Multi V Sync II) • Auto Restart • BLDC Fan Motor • Self Diagnosis • 24 Hour On/Off Timer, Weekly Timer • Group Control • Two Thermistor Control Accessory Option : • Wireless Remote Controller - PQWRHDFO • Standard Type Wired Remote Controller - PQRCUSAO • Simple Type Wired Remote Controller - PQRCUCAO • Simple for Hotel Type Wired Remote Controller - PQRCFCSO • Dry Contact without Case - PQDSA • Dry Contact with Case (1 Contact Point) - PQDSB • Dry Contact with Case (2 Contact Points) - PQDSBC • Front Panel - PT-HJC Location : P.O. No. : Architect : . ■'- - ■ �.. . . ■ . . .•- . V TM Series - 1l2 Ton Indoor Unit 'L r 1 Way Ceiling Cassette Type MULT/ V._ .��. �= Note : . i i � ■ C � �i ... �`� : 7?; u'I�.• ` • I� Li uid Side Pi e Connection �2; Gas Side Pi e Connection :i' Drain Pi e Connection 4'. Power Su I Connection - Air Dischar e Su I ��- Air Suction Return LG Electronics Inc. HVAC Division �n LG Eleclronlcs USA 2008 SD-ARNU073TJC2-VER1 1000 Sylvan Avenue, Englewood Cliffs. NJ 07632 / www.lgusa.com www.lghvac.com Specifications and information in this submittal data are subject to change without notice. �� 1 j�j C �� uJ ✓v� Job Name : Purchaser: Engineer : Submitted To : Submitted By : Unit Desiqnation : Schedule No.: Location : P.O. No. : Architect : Date : For : ❑ Reference ❑ Approval � Construction Model No.: Submittal Data : ARNU073TJC2 Multi V T"" Series -1/2 Ton Indoor Unit •� 1 Way Ceiling Cassette Type Capacities : Cooling Capacitv (Btu/h) 7,500 Power Inqut (W, Coolinq) 40 Heating Capacitv (Btu/h) 8 500 Power Input (W, Heatinq) 40 Cooling Nominal Test Condition : Heating Nominal Test Condition Indoor � 80.6�� DB / 662`r WB Indoor : 68"F DB / 59'r WB Outdoor 95'F DB / 752'P WB Outdoor 44.6'F DB / 42.8"F WB Pipe Length : 25ft per indoor unit Pipe Length : 25ft per indoor unit Level Difference �. Oft Level Difference �. Oft Power Supply : Power Suoplv N,Ph,Hz) 230/208.1.60 Minimum Circuit Ampacitv (A) 1 3 Maximum Overcurrent Protection (Al 15 Full Load Amps (A) 0.2 Fan : Fan Tyqe Cross Flow Fan Quantitv 1 Fan Motor Outaut (1M 20 Air Flow Rate (CFM, H/M/U 265/230/210 Drive BLDC Direct Refrigerant Piping : Refrigerant R410A Control Electronic Expansion Valve Lipuid Side Pipinq (inches, O.D) 1/4 Gas Side Pipinq (inches, O.D) 1/2 Drain Piqinq (inches, O.D, I.D) 1 1/4, 1 Unit Data : Air Filter Mesh Type, Washable Sound Pressure (dB(A), H/M/L Cool, 4.9ft front) 40/38/37 Weight (Ibs, Unit) 25 Weiqht (Ibs. Front Panel PT-UMA) 3 Standard Features : • One Year Functional Parts Warranty • Built-in Drain Pump • ESP Control • Plasma Air Purifying System • Auto Changeover (available with Multi V Sync II) • Auto Restart • BLDC Fan Motor • Self Diagnosis • 24 Hour On/Off Timer, Weekly Timer • Group Control • Two Thermistor Control Accessory Option : • Wireless Remote Controller - PQWRHDFO • Standard Type Wired Remote Controller - PQRCUSAO • Simple Type Wired Remote Controller - PQRCUCAO • Simple for Hotel Type Wired Remote Controller - PQRCFCSO • Dry Contact without Case - PQDSA • Dry Contact with Case (1 Contact Point) - PQDSB • Dry Contact with Case (2 Contact Points) - PQDSBC • Front Panel - PT-HJC M[a/LT/ V.. . '� .'. � �: Note : . •�-�!• ' — — ' - � � � .�, ,�`; . �fa; J'.I�� . ` I Li uid Side Pi e Connection Gas Side Pi e Connection { Drain Pi e Connection �1' Power Su I Connection - Air Dischar e Su I 6 Air Suction Return LG Electronics Inc. HVAC Division �.c) lG Electronics USA 2008 SD-ARNU073TJC2-VER1 1000 Sylvan Avenue, Englewood Cliffs, NJ 07632 / www.lgusa.com www.lghvaacom Specifications and information in this submittal data are subject to change without notice. �� COAfNJk17v OE�ELOwAEtiT Project Name: CERO S.E. - A/C Project Description: Participants: Design Review Board ACTION FORM Department of Community Developme�t 75 South Frontage Road, Vail, Colorado 81657 te1:970.479.2139 fax:970.479.2452 web: www.vailgov.com DRB Number: DR6110400 INTERIOR REMODEL WITH MASTER BATH RECONFIGURATION. CHANGE FLOORING, COUNTERS, PLUMBING FIXTURES AND PAINT. ADD A/C UNIT AND INSTALL NEW APPLIANCES. OWNER CERO S.E. 08/30/2011 URB PUERTO NUEVO 322 AVE DE DIEGO STE 301 SAN JUAN PR 00920-2223 APPLICANT TNT RENOVATIONS LLC 08/30/2011 Phone: 970-471-3246 987 RUBY LN LEADVILLE CO 80461 License: 987-B CONTRACTOR TNT RENOVATIONS LLC 08/30/2011 Phone: 970-471-3246 987 RUBY LN IEADVILLE CO 80461 License: 987-B Project Address: 610 W LIONSHEAD CR VAIL LANDMARK UNIT 704 Location: Legal Description: Lot: 1 Block: 1 Subdivision: LANDMARK CONDOMINIUMS Parcel Number: 2101-063-3007-5 Comments: SEE CONDITIONS Motion By: Second By: Vote: Conditions: BOARD/STAFF ACTION Action: STAFFAPP Date of Approval: 09/O1/2011 Cond: 8 � (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond: 202 (PLAN): Approval of this project shali lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Cond: CON0012124 1. The applicant shall paint the AC unit to match the adjacent wall, as proposed. Planner: DRB Fee Paid: $250.00 � ��� �._�_ � ��� Department of Community Development"�'' � �� �� -� " ,��- ,� � 75 South Frontage Road �' . . ��� � � .�° �;_, � �`.�p �. .y,� �� , �� Vail, Colorado 81�657� �. � � rr -4� " �, � � � � '� ���. � � � � `� . �Te(: � 970-479-2128; � � �,,, � � .�, � ��� . ,. � � � ' , � � > ; .�,� . �, ;q-�� ' 3 ,-r Web: wwv�.vaitgov:com ,� �,� ' � � � �u„;� ���. , _, , � �� Developinent Review Coordinator � 9. � X¢ - , ��. } . n;v���..3K�� �:l � ,t ��' t� . . . . .. .s__ . . .. .. k »�:;�.:� 'mu�".i E � �Q{ �a F�fs�a 1.��, , � r � >....,... _s. , , .- .., _.,.b.s_w+ a �- - . _..�,..�..�».rxsa BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: Project #: � � � – � � C] � /� � �% 1l1/ . LICWS I�Pr � C.Q.. �� (Number) (Street) (Suite #) DRB #: g p � tt���M �'TIZ � Building Permit #: �I ` ` � ��j � Buildin /Com lex Name: f�l I- Z t o�?SN� Lot #: � Block #� Subdivision: _ F'I �1 � � � Contractor Information ----- _ _. ___ __ . __._. ___ ----- --___ ____., ;� � i Business Name: r� � 1����(J ���(�s Work Class: New ( ) Addition ( ) Alterat�on (� Business Address: ��� �k$� �--V�� Type of Building: City c,.��ia4�l,/lL...(�C_ State: �U Zip: 6( Single-Family () Duplex () Multi-Family (� �- � Commercial ( ) Other ( ) Contact Name: � G�� �—��,/�/ C� Contact Phone: �'� O L{ � �–� o��'i �O Work Type: Interior �) Exterior () Both () Contact E-Mail: � c��IVS Valuation of Contrac r�2egistration Number. ��'J ��� �/ork Included Plans Included Woric � „�;; -, Electrical ( )Yes ( )No ( )Yes ( )No �(� X ' � �_ (�CY �, - �-'� �" "�--��// Mechanical ( �es ( )No ( �Yes ( )No ��� Ow /ern Owner's Representative Signature (Required) Plumbing ( �es ( )No (�Yes ( )No �IC Project Information � � FBuilding (./�es ( )No (�)Yes { )No � � Owner Name: M S. ��G� �ro�I I�CL � � :J� Value of all work being pe�formed: $ Parcel #: O� I D� D�� ,� CX�� S �value based on IBC Section 109.3 & IRC Section 108.3% (For Parcel #, contact Eagle County Assessors Office at (970328-8640 or visit www.eaglecounty.us/patie) Electrical Square Footage � C,k� r\ Detailed Scope and Location of Work: �,/� �5��� j� ��,/�v�n�,� (,.J� j�.(°,�5�� 4�,�,�� � . G� R � cX>-.�.� ` �i � ��—e_ � o.r�c� `��..� \ �� � ��_ c�. � �� 4' �-�% `� �� �.-� �—,� 2'� sc.� � (use additional sheet if necess ry j' i For Office Use Only: Date Received: Fee Paid: �r��, � � D Received From: a�� i s 20j� Cash Check # CC: Visa / MC Last 4 CC # exp date: TOWN OF VAIL Auth # O l-Jan-11 ,� � State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmfui asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testinq repuired? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two-Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single-family dwelling: any dwelling unit that is used primarily for a single family, including multi-family/condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified abatement contractor. The clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: � Will not disturb more than the threshold limits identified above. dTested negative, or at 1% or below (1 copies of test results included) � Tested positive at more than 1%, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos-containing materials, so buildings of � age require testing. • The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire_inspectors@vailgov.com 970-479-2252 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303-692-3158 asbestos@state.co.us www.cdphe.state.co.us O 1-Jan-11 . u � :-�a ��L � ) �} � 5� t,� 3,��-� 2 5A� ��fis � �sa�� �I i s% t�JaS(1f,C' r h� ��ro�� �t�-r er � c�u��, �,°kt°P �au�rt� �ry� �ari�m�� � %�`� i � J � ��� % �j��� W - ���.�ow , : �,�40 � ; �oo�l ; 5�000� : 3, o00 �1 ; lf_S OD txI ; s�'o� � ���; I �S� � �.�o.�� ��1��'�-- 8,000� � 17,185� ��, ��sw � ��� = 6, ��y� 6���y�,,� �,��� � ly �7�� - 6�'6h��;�'x 2Sa��-� f jS,soou� r��c� �N � t" �U� � �c�' � � ��S`o � cJ �r�-�a�� 1�18�`�I�y ISS�Ot�r 6�0�� � 3�ij ��Y� �36, 8�ti W�2o �r/ = 177, ��- SGr���� l S �DO.i� � l� 1 �.�. 1''�u� sfi�G�er �ti�, �, �.fi /� �y� �%�-�n�� L%1'-��. C C�[�D�I[� D AUG 2 3 2011 TOWN OF VAIL � �.,_.,� _ , - - , ���-. * - --Foothlll5 Environmental, Inc. Industrial Hygiene, Safety & Environmentat Services May 27, 2011 Todd Turner TNT Renovations 987 Ruby Lane Leadville, CO 80461 Re: Limited Asbestos Inspection at 610 W Lionshead Circle #704, Vail, Colorado FEI Project No. (AS11116) Mr. Turner, Foothills Environmental Inc. (FEI) conducted a limited asbestos inspection on May 23, 2011, of suspect asbestos materials that may be impacted during renovation activities at the residence located at 610 W Lionshead Circle #704, Vail, Colorado. At your request the inspection was limited to suspect drywall materials located in the main level hall bathroom, main level east bedroom, master bathroom and all ceilings in the unit that may be disturbed during renovation activities. Mr. Derek D'Avignon, an asbestos inspector certified by the Colorado Department of Public Health & Environment (#10177), conducted the limited asbestos inspection. Aerobiology Laboratory, an independent laboratory accredited by the National Voluntary Accreditation Program (NVLAP) and the American Industrial Hygiene Association (AIHA), analyzed the samples utilizing Polarized Light Microscopy (PLM). A limited bulk sampling of suspect building materials was conducted to identify any Asbestos Containing Material (ACM) that would be impacted by planned renovation activities in the unit. An ACM is defined by the EPA as a material with an asbestos content of greater than one percent (1%) by area. Select bulk samples of suspect building materials were collected from areas that could be impacted by the remediation effort. Only the textured drywall located within the main level hall bathroom, main level east bedroom, master bathroom and all ceilings was inspected for ACM. FEI did not inspect outside of the proposed scope of work, underground conduit, electrical panels instruments or other appurtenances. None of the samples collected for this limited inspection contained asbestos. Foothills Environmental, Inc. 1320 Simms Street, Suite 102, Golden, CO 80401 (303) 232-2660 1 DESCRIPTION The building is a residential condominium unit located in a seven-story building. The original date of construction is unknown. BULK SAMPLE INSPECTION SUMMARY Suspect Materials • Drywall • Drywall joint compound � Drywall tape • Drywall texture (orange peel) Asbestos Containing Materials (ACM) greater than 1% • None of the samples collected for this limited inspection contained asbestos. The following table summarizes the analytical results of the suspect materials collected for this project: Sample Material Description Sample Location Analytical Results Number 610-704-01 Drywall with joint compound Basement Wall ND* and oran e eel texture 610-704-02 Drywall with joint compound Basement Wall ND* and oran e eel texture 610-704-03 Drywall with joint compound gasement Wall ND* and oran e eel texture * = Multiple Layers ND = None Detected Copies of analytical results are attached to this report for your reference Note: There may be additional suspect asbestos containing materials located under/behind building materials that were not sampled as part of this limited inspection. If additional suspect materials are discovered they should be presumed to be asbestos until sampling and analysis proves otherwise. Foothills Environmental, Ina 1320 Simms Street, Suite 102, Goldeq CO 80401 (303) 232-2660 2 CONCLUSIONS and RECOMMENDATIONS: The Colorado Department of Public Health and Environment (CDPHE) and the Environmental Protection Agency (EPA) define an Asbestos Containing Material (ACM) as a material containing more than 1% asbestos. None of the materials sampled in this limited inspection survey contained asbestos. No further actions are required concerning asbestos containing materials for this proposed project. LIMITATIONS This report describes the locations and conditions of ACM identified in the residence during the inspection. FEI represents that our services are performed within the limits prescribed by applicable regulations and in a manner consistent with the level of care and skill ordinarily exercised by other professional consultants under similar circumstances. No other representation is made to the client, expressed or implied, and no warranty or guarantee is included or intended. This report should not be used as a bid document or Project Design as it does not include components of the design requirements set forth in Colorado Regulation No. 8, Section III.C.3 Please do not hesitate to contact me at (303) 232-2660 if you have any questions regarding this report. Best regards, s` ��-�"�� � . - Derek D'Avignon, Asbestos Inspector # 10177 Attachments - Laboratory Analytical Report Foothills Environmental, Inc. 1320 Simms Street, Suite 102, Golden, CO 80401 (303) 232-2660 3 � A�rzc-,biotoqy Labarzarorzy ASSUL'�lA1tS, INC(�Itl'UIZAItL? ��r.s �.r+►�,aa�a� Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood,CO 80401 3032323746 www.aerobioloqv.net Client Name Foothills Em�ironmental ���� �� Date Collected: OS/23/1 l Street address 1320 Simms St Ste 10_ Date Received: OS/24/1 I City, State ZIP Golden, CO 80401 � Date Analyzed: OS/24/1 I Attn: Lvle Ardourel NVLAP Lab Code 200860-0 Date Reported: OS/24/1 l Client Project Name: Landmark #70-1 Project ID: 1 1006257 Job ID Tesc Requesced: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/1 l6, July 1993. Sample Identification Homo- Layer Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/Layer ge„eous Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sam le Number �Y.�N Percentage Percenta e Percenta e Com osition 11006257-IA White Compound w/White Paint N 8% ND 100 C 610-704-01 l 1006257-1B Green/Tan Drywall N 92% ND 10 90 G 1 1006257-2A White Tape N 5% ND 95 5 11006257-26 White Compound N 5% ND 100 C 610-704-02 11006257-2C White Compound w/White Paint N 5% ND 100 C 1 1006257-2D White Joint Compound N 5% ND 100 C 11006257-2E Tan/White Drywall N 80% ND l0 90 G 11006257-3A White Tape N 5% ND 95 5 610-704-03 11006257-3B White Joint Compound N 10% ND 100 C l 1006257-3C White Texture w/White Paint N l0% ND l00 C Page 1 of 3 A = Amosite AC = Actinolite �/ �� x� /' � �j; �/ AN = Anthophyllite �t,�,.SL_, �'��� �!I � ` cz�`�� ��l�*- '�''�``" CHRY=Chrysotile CR = Croc�dolite TR = Tremolite ic ar egrzyn au nappe Trace=Less Than 1% Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 3032323746 Q = Quartz P = Perlite C = Carbonates B = Binder G = Gypsum D=Diatoms M = Mica T=Tar NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC .dICRU�SIG�GC�v LAC���ftATC�Ry ASSUCtAI t5. INCC�ItI'(�KAI tL� f%�esrsar�e+�t �-t�i�awa�� ClientName FoothillsEnvironmental St�eetaddress 1320 $imms StSte 102 Ciry, State ZIP Golden, CO 80401 Attn: Lvle Ardourel Client Project Name: Landmark Ii704 Certificate of Analysis �I�1dQ ` �� NVLAP Lab Code 200860-0 Tesc Requesced: 3002, Asbestos in Bulk Samples Method: Polarized LiQht Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerobioloav.net Date Collected: OS/23/11 Date Received: OS/24/1 1 Date Analyzed: OS/24/1 1 Date Reported: OS/24/ll Project ID: l 1006257 Job [D Sample Identification Homo- Layer Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/Layer geneous percentage Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sam le Number (Y/N Percenta e Percenta e Com osition 610-704-03 11006257-3D Tan/White Drywall N 75% ND 10 90 Ci Page 2 of 3 A = Amosite AC = Actinolite �� ��' � /� AN = Anthophyllite �I,���� �fx'°-':j''�"'"'" CHRY=Chrysotile CR = Crocidolite TR = Tremolite ic ar egrzyn au nappe Trace=Less Than 1% Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected 13949 W. Colfas Ave. Suitz 205, Lakewood CO 80401, 303232.3746 Q = Quartz P = Perlite C = Carbonates B = Binder G = Gypsum D=Diatoms M = Mica T=Tar NTR = Non-Asbestifonn TR NAC = Non-Asbestiform AC /�t�zc�L�ivlc�yy LAt�c��uaivr=Y Atiti(><'IAItS, INC:OIt1�C)I2AIF1) �� C`�r Foothills Environmental 1320 Simms St Ste 102 Golden, CO 80401 Lyle Ardourel Client Project Name: Landmurk #7U-4 General Notes Certiticate of Analysis a�da��� NVLAP Lab Code 200860-0 Date Collected: Date Received: Date Analyzed: Date Reported: Project ID: Job ID: 13949 W. Colfax Ave s��ce zos Lakewood, CO 80401 303.232.3746 www.aerobioloqv net OS/23/ 11 OS/24/ 1 I OS/24/I1 OS/24/II 11006257 ♦ ND indicates no asbestos was detected; the method detection limit is i fiber. ♦ Trace or °<1" indicates asbestos was identified in the sample, but the concentration is less than 1%. ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the asbestiform varietv of the mineral reibekite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected bv PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under the NESHAPS regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to retum the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discazding. A shipping and handling charge will be assessed for the return of any samples. ♦ Aerobiology does not gaurantee the reuslts of tape lifts, microvacs, wipe, and/or debris sa�nples. Accurate analysis cannont be prefonned due to particle size, media used, and/or amout of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that dre samp/e area does not coi�tain. It means t/re ana/yst could not identify asbes�os in the speciftc sample for Nte reasons listed above. Notes Reauired bv NVLAP ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP-approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 ��� .,,. �,� , � � �� � 01-04-2012 Inspection Request Re�ortin va�i r_n _ c�fi, n Requested Inspect Date: Thursday , January 05, 2012 Site Address: 610 W LIONSHEAD CR VAIL LANDMARK UNIT 704 � Page 5 A/P/D Information Activity: 611-0280 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: R-2 Insp Area: Owner: CERO S.E. Contractor: TNT RENOVATIONS LLC Phone: 970-471-3246 Description: INTERIOR REMODEL WITH MASTER BATH RECONFIGURATION. CHANGE FLOORING, COUNTERS, — PLUMBING FIXTURES AND PAINT. ADD A/C UNIT AND INSTALL NEW APPLIANCES. �� R�nspection s ' Item: 542 PLAN-FINAL Requestor: TNT RENOVATIONS LLC � Comments: 471-3246 Assigned To: BGIBSON Action: Ti xp: 1--- _-- �— Item: 90 BLDG-Final Requestor: TNT RENOVATIONS LLC Comments: 471-3246 Assigned To: J DRAGON Action: Time Exp: Item: 190 ELEC-Final Requestor: TNT RENOVATIONS LLC Comments: 471-3246 Assigned To: JMO ON Action: Time Exp: Item: 290 PLMB-Final Requestor: TNT RENOVATIONS LLC Comments: 471-3246 Assigned To: JM D GON Action: ; Time Exp: Item: 390 MECH-Final Requestor: TNT RENOVATIONS LLC Comments: 471-3246 Assigned To: J AGON Action: Time Exp: '�4�.�-(�` 11/�UIV1 i �j �c ��� � � J � � S�( 2 Inspection History Item: 30 BLDG-Framing "" Approved "' 10/31/11 Inspector: sgremmer Comment: Item: 50 BLDG-Insulation Item: 60 BLDG-Sheetrock Nail "� Approved `" REPT131 Requested Time: 08:00 AM Phone: 970-471-3246 Entered By: JMONDRAGON K Requested Time: 01:00 PM Phone: 970-471-3246 Entered By: JMONDRAGON K Requested Time: 10:30 AM Phone: 970-471-3246 Entered By: JMONDRAGON K Requested Time: 11:00 AM P hone: 970-471-3246 Entered By: JMONDRAGON K Requested Time: 11:30 AM Phone: 970-471-3246 Entered By: JMONDRAGON K Action: AP APPROVED __ _ _ _ _ Run Id: 13955