Loading...
HomeMy WebLinkAboutB11-0292 NOTE: TH/S PERMIT MUST BE POSTED ON JOBS/TE AT ALL T/MES � . .,� �ou�o���u ,. Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0292 Project #: PRJ11-0354 Job Address: 1290 WESTHAVEN CR VAIL Applied.....: 08/24/2011 Location......: Issued... : 09/16/2011 Parcel No....: 210312403005 OWNER SEP-HAVEN LLC 08/24/2011 12770 MERIT DR STE 1000 DALLAS TX 75251 APPLICANT HOEFT BUILDERS WEST�NC 08/24/2011 Phone:970-904-1959 PO BOX 6332 AVON CO 81620 License: 1078-B CONTRACTOR HOEFT BUILDERS WEST INC 08l24/2011 Phone:970-904-1959 PO BOX 6332 AVON CO 81620 License: 1078-B Description: ADDIT�ON OF RETAINING WALLS, PATHS,PATIOS,GAS FIREPIT, SPA,PLANTING AND LANDSCAPE LIGHTING. Occupancy: Type Coristruction: Valuation: $103,000.00 .........................,,..,.....,..,,.,.........,,.......,..,.................... FEE SUMMARY .,.....,..........,...,..,.,...................,,......,..,,.......,,,,.,.....,,. Building Permit-----------> $1,010.55 Bldg Plan Check----------> $656.86 Use Tax Fee-----------------------> $1,860.00 Electrical Permit---------> $201.25 Elec Plan Check-----------> $130.81 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $60.00 Mech Plan Check---------> $15.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $30.00 Plmb Plan Check---------> $7.50 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 TOTAL PERMIT FEES-------------> $3,991.97 Payments------------------------------> $3,991.97 BALANCE DUE-----------------------> $0.00 ......................................___......,..,,......,...,.......,......�.............,,.,...........�.......,.....,,.,,................,,.,.................,,.............,...,...,.. DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the town's zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHAL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:OOAM-4:00� � 9- /6-/� Signa re o Ow r or Contractor Date P�r.� k Na ��� Print Name combination permit_012811 � i ������� a ..............,.....,,_.,,...,,_.....,.__...._,......_.._..,,._.,...........,,...x.............,...«....,«......�......«.........,,.....�...,,...,,....,...........,�.............�...,,..,_... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: B11-0292 Address: 1290 WESTHAVEN CR VAIL Owner: SEP-HAVEN LLC Location: .................................................................».......,...............�...........,,,,,......................................,......,,,...x.,,,................... combination permit_012811 . l 1 V f1l� tf��� , *.**.,*..,.«.*.,,,..**..*«**„**„«****«„«„*„«««,...*.*,«**.*�*****�*************««*„******«.,.,**«««««*««««...,.***,.*********«««««**«*.,,«,,.,,,*****,.**.***««*«** REQUIRED INSPECTIONS AND STATUSES Permit#: 611-0292 Address: 1290 WESTHAVEN CR VAIL Owner: SEP-HAVEN LLC Location: *,,,,..**.**********,.****,,*�,.��,�*,.,.*�*,,********„******««**„*,,**„************,.**********,.**�******„*****�*******************.,****«.,«�**«„*.************* Item: 00010 BLDG-FOOTING Item: 00020 BLDG-Foundation/Steel Item: 00030 BLDG-Framing Item: 00070 BLDG-Misc. Item: 00120 ELEC-Rough Item: 00190 ELEC-Final Item: 00200 MECH-Rough Item: 00220 PLMB-Rough/D.W.V. Item: 00230 PLMB-Rough/Water Item: 00240 PLMB-Gas Piping Item: 00250 PLMB-Pool/Hot Tub item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00542 PLAN-FINAL Item: 00090 BLDG-Final combination permit_012811 i ' , ��511- p3S�� 12-29-2014 Inspection Request Re orting Page 10 7:44 a m !A!?�` Requested Inspect Date: Monday December 29, 2014 Site Address: 1290 WESTHAVEN CR VAIL A/P/D Information Activity: 611-0292 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: SEP-HAVEN LLC Contractor: HOEFT BUILDERS WEST INC Phone: 970-904-1959 Description: ADDITION OF RETAINING WALLS, PATHS, PATIOS, GAS FIREPIT, SPA, PLANTING AND LANDSCAPE LIGHTING. Requested Inspection(s) Item: 542 PLAN-FINAL Requested Time: 08:30 AM Requestor: Phone: Comments: Expired Assigned To: GRUT� I Entered By: MHAEBERLE K Action: � Time Exp: Comment: na e inspec re-vegetation due to snow, a re-inspection is required in the spring. Comment: Unable to �nspect landscaping due to winter conditions. Re-inspections required. Item: 90 BLDG-Final Requested Time: 03:00 PM Requestor: Phone: Comments: Exp ired Assigned To: SGREM� I Entered By: MHAEBERLE K Action: ✓1�' Time Exp: Comment: wai ing or e anning department to sign o Comment: Permif exte sion from last inspection dafe Inspection History Item: 10 BLDG-FOOTING "'Approved ** 09/30/11 Inspector: JRM Action: AP APPROVED Comment: Item: 20 BLDG-Foundation/Steel *"Approved'" 09/30/11 Inspector: JRM Action: AP APPROVED Comment: Item: 30 BLDG-Framing '"Approved "* 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 70 BLDG-Misc. "*Approved "* 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 120 ELEC-Rough "'Approved*" 09/22/1 i Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC-Final **Approved'" 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough "Approved `* 09/30/11 Inspector: JRM Action: AP APPROVED Comment: SNOWMELT Item: 220 PLMB-Rough/D.W.V. "`Approved "" 11/21/1 T Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB-Rough/Water ""Approved** 11/21/1 T Inspector: sgremmer Action: AP APPROVED REPT131 Run Id: 14758 *****+*****************************�***+****++***+++++*+************++****************+*+*** TOWN OF VAIL, COLORADO Statement ******************+++**++*+***+***********�******************************�+***+*+********�** Statement Number: R110001238 Amount: $3,335.97 09/16/201112:52 PM Payment Method:Credit Crd Init: LC Notation: CREDIT CARD FROM PATRICK J HOEFT, HOEFT BUILDERS WEST ----------------------------------------------------------------------------- Permit No: B11-0292 Type: COMBINATION BLDG PERMIT Parcel No: 2103-124-0300-5 Site Address: 1290 WESTHAVEN CR VAIL Location: Total Fees: $3, 991.97 This Payment: $3, 335.97 Total ALL Pmts: $3, 991.97 Balance: $0.00 ***+*******************************************************************************�******** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 1, 010.55 EP 00100003111100 ELECTRICAL PERMIT FEES 201.25 MP 00100003111100 MECHANICAL PERMIT FEES 60.00 PF 00100003112300 PLAN CHECK FEES 154.17 PP 00100003111100 PLUMBING PERMIT FEES 30.00 UT 11000003106000 USE TAX 4% 1, 860.00 WC 00100003112800 WILL CALL INSPECTION FEE 20.00 ----------------------------------------------------------------------------- .. . . _ _ , _ . ., .. � , �� � .� � ; � `:��s Department,of Communf#y Development ' ��� �;� � �;�� '� 3 Y ���,;� ' �_..�, 75 South Frontage Ro�d� . � ;. � : � -�'��.:� � - .� �� �, � '� ��� �� � ��'� r, � � Vail, CQlora.do 8�3.6.5��� �, � � �'fi�.�- °� ��,: �°��,: � Tei: 9�0-479 2'�2�-� f� '� � �,� � �'��4�.��� �;=,.� � $ Fa3c: 97f3-4�'9�24��� �f� � ,��`�,�,.''� �` �, ; ` ,'� � ,� ` €;� �- _ �� ��: � �' �`_� � • � ��.�h; �� VYOb WWW Vai�fllf�O �,������, . � �.�,.�<°� . .�� ,- ;, � ��<<. .,a �s _ � �, � ���` . - Deve7vpinenf=Re�r�einr Corsrd�trt�t� � � "' E������ .%�� � �� -��' _ . ����. ��� � �"��� , . y�� s , : � �_ �� ��` „ � , _.. . . s r' ., -�.F„�_�....�__' ;r_ .,�.,��.k .,r< -p`�-"' &,�,x �, ._� ,, .,�_a:°.s.._.� - �. ; TRANSMITTAL FORM Revision Submittals: 1. "Field SeY'of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved&the permit is re-issued. 3. Fees for reviewing revisions are$55.00 per hour(2 hour minimum), and are due upon issuance. Permit#(s)informationrvappliesto: � LLW�_.__. _.... _____. .___._.__.._�.,_�_,_._.. . . _._�� Attention: ( ) Revisions � � ( ) Response to Correction Letter ; R�' a� attached copy of correction letter ' ( ) Deferred Submittal ; ( ) Other Project Street Address: ; `•'�` �l l�u v`�L � � Description/List of Changes: ;(Number) (Street) (Suite#) T � ')„� �w� , �!4 / f�; r ' Building/Complex Name: N �"f ��� 5 � ln o � Y r � ,�. �Contact Infor ation: . �_�..�_ ...�.,.o_,._..,, _�,�. ...��.,_F �.,,�_.�.,.....,�,.„.._..� ��/ s Company:, ut, f �, � t✓f �l�L� ;CompanyAddress: �� ��( 6�32- . ��IE�rs �C.�.�, �e. � , � , L�a.D, City_ ��)U v► State:�Zip: �I O �^�a• � , ��).� : `Contact Name: �i � �c � HoiTt — `Contact Phone: ��D � ����'f��% � 'E-Mail �ati�Lk ��oLTfib.��'Ut�� 1.�C�jf � � ��'� i � Revised ADDITIONAL Valuations(Labor 8�Materials) '(DO NOT indude original valuation) Building: $ � ;(use additional sheet if necessary) ! _........_.. ___ . .._.....__.. _...__... . __....... Plumbing: $_�? Date Receiv �( """ ' Electrical: $ 6 � `� � � �� Mechanical: $ � ���:+ � � �d;� ;Total: $ ' - f TO WN OF °_�__....___..__�.__...___..__.__,__.__._.---_._____.___,____�__._._____.__.�..� VqIL O l-Jan-10 Patrick Hoeft To: Martin Haeberle Subject: RE: 1290 Westhaven Circle B11-0292 From: Martin Haeberle jmailto:MHaeberle@vailgov.com] ,, Sent: Tuesday, September 06, 2011 1:50 PM ' To: 'patrick@hoeftbuilderswest.com' Cc: JR Mondragon Subject: 1290 Westhaven Circle B11-0292 Please revise plans to reflect the following and resubmit two sets. 1. Town of Vail amended code requires the following: I Section 414.4 IFGC Fire pits serving all residential units require automatic shut-off controls with a maximum timer of thirty(30) minutes and may only be served by a 3/4"gas pipe. Indicate on plans the required shutoff device for the fire pit. P�EASE SEE ATTACHED 2. Boulder wall design to be sealed by the registrant PLEASE SEE ATTACHED 3. Show compliance with the barrier requirements of the spa per section AG105 IRC PLEASE REFER TO SHEET LC 2.1 FOR RE�i!SED DETAIL 4. Indicate that CO detectors have been installed through out the home or are to be installed. PLEASE REFER TO SHEET LC 1.0 FOR REVISED DETAIL 5. 5. Indicate a pool/spa cover of a min. R-12 is to be used. PLEASE REFER TO SHEET LC 2.1 FOR REVISED DETAIL Thank you Martin Martin Haeberle Building Official Community Development rowN oF vAi� ; 970.479.2142 970.376.2672 vailgov.com twitter.com/vailgov � :;y.�K�I.i_ FI1r11.GRr1DE �:;'`'�,`n�:� , ,p' HEF: NUTF H REF:Iv'OTE 6 REF: ,.�`�Tr , — — f i f � 2� � �`i== tRlaX! I � ` ` --� ► � � I �i � ; _' ��r�iin} � � � � �� � � i Q 1 — � 2i3H�m�n) W---� 1 � 2� \ CUT FACE � � REF: NOTF I i��� .: �n���.txl � � 6ACKFILL REF: NC;T�o / —f QRAIN CiRA�dEL REF: NOTE 3 / \FINISH GRADE \ / '''pnin) J \ � ! ------- -;��---� _,=i-1 �n��;�. �� DRAIN PIP� REF� NOTF '�' NOTES: 1. Bouiders with minimum size of 2'. Embed first course a minimum of 12"below adjacent final graded ground surface. 2. Minimum 4"diameter perforated drain pipe sloped to gravity outlet. N�L. Pq �f..s-....�.�L 3. 3/a"screened rock as drain gravel. Cover top side with filter fabric such as Mira ' �,J;' �s � • � 4. Slope cut face to a safe/stable grade. _ . �_ • 5. Slopes between tiers and above wall graded no steeper than 2 horizontal to rt .� • 6. On-site granular soil compacted to minimum 90% of standard Proctor density(SP }. :� � 622� : •� � • 4 � =:� �� : . c!'l�l��p�A1,����P�O E p� �p�0 111 230A ~ c�CPt�CI''�1 TYPICAL BOULDER WALL SLOPE DETAIL FIG. 1 -_?'+10RTN•aAy�lArt G_0'E��+viCAl Department of Community Development 75 South Frontage Road TOWN OF VAIL " va�i, co$�ss� Tel:970-479-2128 www.vailgov.com Development Review Coordinator , BUILDING PERMIT APPLICATION (Separate applications are required for alarm &sprinkler) Project Street Address: ��'� �_�'�C"'..J� Project#: 1290 Westhaven Circie (Number) (Street) (Suite#) DRB#: �ti��� �,�� ( Building/Complex Name: Building Permit#:�� �C1oZ�� Contractor Information Lot#: Block# Subdivision: Business Name: Hoeft Builders West INC 1078-B Work Class: New( ) Addition ( ) Alteration(✓) Business Address: PO Box 6332 Avon CO 81620 Type of Building: City State: Zip: Patrick Hoeft/Hoeft Builders West INC Single-Family(✓) Duplex( ) Multi-Family( ) Contact Name: Commercial( ) Other( ) Contact Phone: 970 904 1959 atrick hoeftbuilderswest.com �Nork Type: Interior( ) Exterior(✓) Both( ) Contact E-M ' • �° Valuation of X ` Work Included Plans Included Work Owner/Owner's pre ti e Signature(Required) Electrical (✓ )Yes ( )No ( )Yes (✓ )No � Applicant Information Mechanical (�)Yes ( )No ( )Yes (✓ )No OU Applicant Name: Sephaven LLC Plumbing (� )Yes ( )No ( )Yes (✓)No j�_ Applicant Phone: 970 904 1959 Building ( ✓jS'es ( )No ( )Yes ( )No 9� Applicant E-Mail: Patrick@hoeftbuilderswest.com Value of all work bein g performed: $ b (value based on IBC Section 109.3 8 IRC Section 108.3� Project Information Sephaven LLC Electrical Square Footage �.l�� Owner Name: Parcel#: 2103-124-0300-5 (For Parcel#,contact Eagle County Assessors Office at(970-32&8640 or visit www.eaglecounty.us/patie) Detailed Scope and Location of Work: Addition of hot tub pit for self contained hot tub at west side of house, addition of fire pit at west side of house additions of boulder walls to accomodate new landscape layout and repair existing stairs to meet code. (use additional sheet if necessary) For Office Use Only: Date Received: (� �, n ` 1 Fee Paid: �(QS�.�O D LC U !� LJ \�/ � Received From: Pf�}TQ1Ck AUG 2 3 2011 Cash Check# CC: Visa / MC Last 4 CC # �� exp date: n 1 Auth # D39gR9 ��rR�� 3• HoEFr TOWN OF VAIL �� 2 Lv 5 oi-.raz,-i t . Patrick Hoeft ��A N/� � From: Mario[mario@avonplumbers.com] Sent: Tuesday, August 23, 2011 7:41 AM To: Patrick Hoeft Subject: RE: Avon Plumbing - 1290 Westhaven Cr. i Patrick, 'I There is a 2" underground medium pressure gas supply line from the gas meter to the location of inechanical units on the east side of the house. From existing gas pressure regulator at this location we will install one 1- 1/2" underground gas line for the exterior fire pit(450,000 BTU) and one 1" underground line for exterior BBQ , (100,000 BTU). The distance from the gas pressure regulator to the patio is about 80'. Old underground gas ', supply line will be disconnected and abandoned as it would not supply enough gas for both appliances and old I stub-outs would not work for new locations. I Please let me know if you need any moqre details or if you need any drawings for TOV. I Thank you, Mario On Tue, 23 A 2011 07:26:12 -0600, Patrick Hoeft wrote: Looks great, I still n the load calcs though for the permit can you get those to me. From: Mario mailto:mario avon lumbers. Sent: Friday,August 19,2011 1:40 PM To: Hoeft Builders West, Inc.-Patrick Subject:Avon Plumbing- 1290 Westhaven Cr. Patrick, attached is a proposal for the ins ation of gas supply lines at 0 Westhaven Cr. Please let me know i fyou have any questions. Thank you, Mario Avon Plumbing, Inc. i r Load Caiculation 1290 Westhaven Circle 3/18/11 . � 1�. l • General Lighting and Receptacle Demand Load: 6500 sq. ft. x 3VA= 19500 220.3(a) , 1,500 VA x 2= 3000 220.16(a) 1,500 VA x 1 = 1500' 220.16(b) actual connected lighting load: 39,830; �� Total connected load: 44,330 ---- —--- - _ — ---- ----- -- ___ - - — ---------- -- 3,000 VA @ 100%= 3,000 220.11 ' VA 35%= 41,3301 14465.5' Total general lighting and Receptacle demand load: 17,466' -- - - -- ------- -T Range demand load: 000! _ ____ _ ___ 12,OOOVA 8, 220.19 Dryer Load: 5,000' 220.18 5,000 x 3 15,OOOI _ ___ __ -_ __ - - - �- - Fixed appliance load: Dishwasher 1.2 kva x 2 2,400 Garbage disposal .8 kva x 2 1600 Sub-Zero 1.2 kva x 2 2,400 Steam shower 9.6 kva x 1 9,600 Hot tub t2 kva x 1 12,0(}0 _ - -_ _ _ -__ _ _--- ----- Total fixed appliance load: 28,000 A-Phase Electric, LLC 970-926-4443 y Load Calculation 1290 Westhaven Circle 3/18/11 Heating load: ' Boiler 50 2 100 Pump 50 11 550 Heat Tape 1100 6 6,600 Total heating load: 7,250 -- --- - --- __ ___ 25%of largest motor: 1,200 Totals: -___ _ _ _- -- ---- General lighting and receptacles: 17,466 Range: 8,000 Dryer: 15,000 Fixed appliance: 28,000 Heating: 46,300 25%of largest motor: 1,200 --- - ---- — - TotaL• 1159 kva 483.2 amps Installed Service Size: 600A 120/240 Secondary Conductors: paralle1350kcmil CU Distance from vault to meter: 210' A-Phase Electric, LLC 970-926-4443 LEVEL 4 PANEL A-7 _ _ _ _ .__ ._ 150A _ _ _ _ __ _ _ _ _ _ _ LEVEL 3 ___ _ _-- --_._ _.. _ PANEL PANEL PANEL A-3 A 5 A'r8 2QOA 15�A 15� A , -- -------- --------- ---_----------------------- LEVEL 2 __ __ _ , __ . _._ ---_ ._._ - - __ i i __, PANEL i A�4 20bA LEVEL 1 PANEL ' I , ww , � O PANEL PANEL lJl.1l.X.�.J ----__ (� CT . _. . PANEL I I jMQ�P : Ail A2 A'3 �00/� 8 A 20 A � ! 6010A � �'� SI N -------- �----— �20�240 � �L�PHASE ! _ ___ _ -- — I - ---- � _._-- _ '._ _._._ _ __ __--- - — ' SINGLE-LINE WIR/NG D/AGRAM DRAWN BY CHECKED DATE SCALE SHEET NO. 1290 WESTHAVEN CIRCLE VAIL, CO A-PHASE 3/18/11 NONE � � ELECTRIC w - ' � Hli�������rth-I'�i��l,�l. �..�c��ir�lini�.il, In� � P �l�_'��l:�,unti R�>�iJ I?� � Gl�m�����.l ti��iint:,(���I��ra�l�,ti l b��l I'h��nr:�)i0-��+�-7�Jtib HEPWORTH-PAWLAK GEOTECHNICAL �.,\ ,�-;, ,i�; ��;� cnr.ul: h�,�_. �3h�,.�,rrih.��mi August 22, 2011 Ceres Landscape Architecture Attn: Paul Heding � P. O. Box 2134 I� Eagle, Colorado 81632 I' (paul�,ceres-�lt us•com) I, I Job No. I 11 230A !� i Subject: Recommendations for Stacked Boulder Wall Slope Design, Lot 26, Glen Lyon Subdivision, 1290 Westhaven Circle, Vail, Colorado Dear Paul: As requested, we are providing recommendations for design of the proposed stacked boulder wall slope at the subject site. The services were performed in accordance with our agceement for professional engineering services to Ceres Landscape Architecture, dated July 29, 2011. A review of the site was made on August 17, 2011. Hepworth- Pawlak Geotechnical previously performed a subsoil study for the residence foundation design on Lot 26 and presented our fmdings in a report dated June 27, 2001, Job No. 401 157. Site Conditions: The boulder covered slope is proposed to extend east from the existing boulder walls and terraces constructed for Lot 26 residence, and onto Lot 27. The new terraces will involve cut and fill depths typically up to 4 to 5 feet and include a spa and fire pit on relatively level ground. The existing terrain is moderate to steep sloping, natural north facing hillside covered with a mixed aspen and pine tree forest. Most of the dead pine trees have been rernoved from the uphil] parts of Lots 26 and 27. The hillside slopes up from Westhaven Circle at about 25%then increases gradually to about 30 to 50% through the proposed stacked boulder slope area. Lot 27 is vacant. No indications of hillside slope instability, such as seeps or slumps were observed within or adjacent to the project area. The existing stacked boulder walls on Lot 26 where they will tie into the proposed walls appear to be performing adequately although we have not performed any review or analysis of the constructed wall sections. For our previous subsoil study, a boring was drilled on the lower part of the lot. The boring encountered clayey silty sand with gravel and cobbles and no free water to the depth drilled of 25 feet in June 2001. Recommendations: Stacked boulder walls slope up to about 5 feet tall to retain shallow cuts and fills should be feasible with proper design and construction. The boulder walls are designed as gravity retaining structures with adequate section for stability. The individual tiers should be limited to 4 feet exposed height. The walls 3 feet or more in retained height should be provided with an underdrain system to prevent buildup of ['arker il��.�4�}1-711�) � <:�,1�-+racir, ti�,rin:,�. r 1�)-(��i-751i? • �il��rrrh�,rn� �)7l�-=}6ti-I�>,��? � � Ceres Landscape Architecture August 22, 201 l Page 2 hydrostatic pressure. A typical detail for the stacked boulder wall slope section is provided on Figure 1, attached. The boulders should be subangular shape and minimum 2 feet in size(or larger) with the larger boulders placed at the bottom of the wall. The base width of the walls should be a � minimum '-/3 the wall height. The base of the wall should be keyed below the ground ' surface at least 1 foot and bear on the natural granular soils. The topsoil should be I removed and loosened soils should be moistened and compacted �rior to placing the I boulders. The face of the wall slwuld be battered back at about '/2 horizontal to 1 vertical. � The space between and behind the boulders can be backfilled with 3/-inch drain rock. A '�I filter fabric, such as Mirafi 140 N, should separate the on-site soils from the drain rock. Graded slopes between the wall tiers and above the walls should be graded at 2 horizontal � to I vertical or flatter and vegetated to prevent erosion. We should observe the excavation and construction of the boulder walls to evaluate compliance with our recommendations. The recommendations presented in this report are based on our review of the project site and our experience in the area. Exploration to evaluate the subsurface conditions for slope stability analysis has not been performed. Variations could be encountered during construction and change the recommendations presented in this report. We should evaluate the bearing conditions and compaction ofbackfill for the individual walls at the time of construction. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH — PAWLAK GEOTCHNICAL, INC. �N�L• Fq ,..�....�. ,;�v6�� �� �' j�.e s � Steven L. Pawlak, P.E. �; � �2�� ; . . . o'� ��// 1 0`��-;. "2��/ `'��i Rev. by: DAY �'` ��'c%r;.�t Ea:'o ,.� �,O ��`' j ;JF'LJ�-fl0. SLP/ljg Attactvnent: Figure 1 - Typical Boulder Wall Slope Detail Job No. I 11 230A Gec�tECh EACKRLL FiNAL GRADE BOULDER(TYP) REF: NOTE 6 REF:NOTE 6 REF: NOTE 1 f i / \ ' zr H==4'(max) � ' � ' � I 1' l '� �� � � �� ���� I 12"(min) � � / 2/3H(min) i � 2� ` CUT FACE � REF: NOTE 4 H=4'(max) \ / BACKFILL � REF: NOTE 6 � �' DRAIN GRAVEL REF: NOTE 3 / \ — FMISH GRADE \ � � t 2"(min) .� 2/3H (min) DRAIN PIPE REF: NOTE 2 NOTES: 1. Boulders with minimum size of 2'. Embed first course a minimum of 12"below adjacent final graded ground surface. 2. Minimum 4"diameter perforated drain pipe sloped to gravity outlet. 3. 3/"screened rock as drain gravel. Cover top side with filter fabric such as Mirafi 140N. 4. Slope cut face to a safe/stable grade. 5. Slopes between tiers and above wall graded no steeper than 2 horizontal to 1 vertical. 6. On-site granular soil compacted to minimum 90°,6 of standard Proctor density(SPD). 111 230A ��C�'t�C�l TYPICAL BOULDER WALL SLOPE DETAIL FIG. 1 HEPWORTH-PAWLAK GE�iECHNICAL .� 01-02-2013 Inspection Request Reporting Page 1 4•13 t�m Vail, CO -�tTOf Requested Inspect Date: Thursday,Janua 03 2013 Site Address: 1290 WESTHAVE�C�i VAIL A/P/D Information Activity: 611-0292 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: SEP-HAVEN LLC Contractor: HOEFT BUILDERS WEST INC Phone: 970-904-1959 Description: ADDITION OF RETAINING WALLS,PATHS, PATIOS,GAS FIREPIT,SPA,PLANTING AND LANDSCAPE LIGHTING. Reauested Inspection(s�l�►°�v�J�-�i Item: 90~BtBG-Final Requested Time: 03:30 PM Requestor: Phone: Comments: follow u Assigned To: JMON�RAGON Entered By: JMONDRAGON K Action: Time Exp� Comment: wai ing or e p anning department to sign off— ��1.n�v'��.C, "fO '`ti•'�,�"f �t�sGapT"'� �uG -�o w i`�y. Ga�-sl%��i'r,S. ��- T n.Sp��'6h �G!/C+^'r� . r� � Insuection Historv Item: 10 BLDG-FOOTING "Approved" 09/30/11 Inspector: JRM Action: AP APPROVED Comment: Item: 20 BLDGFoundation/Steel '*Approved" 09/30/11 Inspector: JRM Action: AP APPROVED < Comment: Item: 30 BLDG-Framing "Approved" 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 70 BLDG-Misc. "Approved" 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 120 ELEC-Rough *"Approved" 09/22/1 i Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC-Final "Approved`* 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough "Approved" 09/30/11 In�sp ector: JRM Action: AP APPROVED Comment: SIYOWMELT Item: 220 PLMB-Rough/D.W.V. '"Approved" 11/21/1T Inspector: sgremmer Action: APAPPROVED Comment: Item: 230 PLMB-Rough/Water "'Approved" 11/21/1 i Inspector: sgremmer Action: AP APPROVED Comment: Item: 240 P�MB-Gas Piping "Approved" 09/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 250 PLMB-PooUHot Tub '*Approved'* 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 290 PLMB-Final "Approved'* 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 390 MECH-Final *'Approved" 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 533 PLAN-TEMP.C/O *'Approved" REPT131 Run Id: 14636 J � � .�.-� 12-29-2014 Inspection Request Reporting Page 10 7'44 am Vail, CO - Citv �f Requested Inspect Date: Monday December 29, 2014 Site Address: 1290 W�STHAVEN CR VAIL A/P/D Information Activity: B11-0292 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: SEP-HAVEN LLC Contractor: HOEFT BUILDERS WEST INC Phone: 970-904-1959 Description: ADDITION OF RETAINING WALLS, PATHS, PATIOS, GAS FIREPIT, SPA, P NTING AND LANDSCAPE LIGHTING. Requested Inspection(s1 �• � �` I � 1 Item: 542 PLAN-FINAL R es ed Time: 08:30 AM Requestor: /�� " Phone: Comments: Ex ired Assigned To: G�UTHER �� Entered By: MHAEBERLE K Action: Time Exp: Comment: na e o mspec re-v getation due to snow, a re-inspection is required in the spring. Comment: Unable to inspect landscaping due to winter conditions. Re-inspections required. Item: 90 BLDG-Final Requested Time: 03:00 PM Requestor: Phone: Comments: Exp ired Assigned To: SGREMMER Entered By: MHAEBERLE K Action: Time Exp: Comment: wai ing or e p anning department to sign o Comment: Permif extension fromlast inspection daie Inspection History Item: 10 BLDG-FOOTING **Approved'* 09/30/11 Inspector: JRM Action: AP APPROVED Comment: Item: 20 BLDG-Foundation/Steel *'Approved"" 09/30/11 Inspector: JRM Action: AP APPROVED Comment: Item: 30 BLDG-Framing ""Approved** , 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: i \ Item: 70 BLDG-Misc. "'k Approved** 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 120 ELEC-Rough `*Approved"" 09/22/1'f Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC-Final *'Approved'" 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough **Approved""' 09/30/11 Inspector: JRM Action: AP APPROVED Comment: SNDWMELT Item: 220 PLMB-Rough/D.W.V. "*Approved*" 11/21/1 T Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB-Rough/Water ""Approved*" 11/21/1T Inspector: sgremmer Action: APAPPROVED REPT131 Run Id: 14758 � 11-16-2011 Inspection Request Reporting Page 17 4:45 pm Vail,Sc�j=Gitv Of Requested Inspect Date: Thursday November 17 2011 Site Address: 1290 WESTHAVEN CR�AIL A/P/D Information (°251�"b3S� Activity: B11-0292 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: SEP-HAVEN LLC Contractor: HOEFT BUILDERS WEST INC Phone: 970-904-1959 (���.� Description: ADDITION OF RETAINING WALLS, PATHS, PATIOS, GAS FIREP T, SPA, PLANTING AND LANDSCAPE LIGHTING. �� • � T� � ���. �,�, Requested Inspection(s) �Go �'"�� �br� ��'� �� ' � ���'� Item: 542 PLAN-FINAL � ���� 5 �'�;�Requested Time: 09:00 AM Requestor: � c � Phone: Comments: 904-1959 rye `� `N� C�e Assigned To: BGIBSON �` �" �v'� -�h Entered By: MHAEBERLE K Action: Time Exp: 1�`�I�� Item: 90 BLDG-Final � �' Requested Time: 02:30 PM Requestor. �'V Phone: Comments: 904-1959 Assigned To: JMONDRAGON Entered By: MHAEBERLE K Action: Time Exp: Item: 30 BLDG-Framing Requested Time: 01:00 PM Requestor: Phone: Comments: 904-1959 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: Item: 220 PLMB-Rough/D.W.V. Requested Time: 02:00 PM Requestor: Phone: Comments: 904-1959 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: Item: 230 PLMB-RoughlWater Requested Time: 02:30 PM Requestor: Phone: Comments: 904-1959 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: Item: 250 PLMB-Pool/Hot Tub Requested Time: 03:00 PM Requestor: Phone: Comments: 904-1959 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: Item: 290 PLMB-Final Requested Time: 03:30 PM Requestor: Phone: Comments: 904-1959 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: Item: 390 MECH-Final Requested Time: 04:00 PM Requestor: Phone: Comments: 904-1959 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: REPT131 Run Id: 13781