HomeMy WebLinkAbout10-039 20110714 Parking Column
Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy · Suite 110 · Lakewood, CO 80228-2845 www.KCE-Denver.com LAKEWOOD (303) 989-1223 (303) 989-0204
FAX GRAND JUNCTION (970) 241-7700 (970) 241-7783 FAX Job No. 10-039 Location: Second Level Parking Column on Gridlines EA and E-18.7 Total Cubic Yards: 2 Supplier: Lafarge Ticket No:
85909777 Mix Design No: RMXCE45DG8V Slump: 3.75 Air Content: 7.5 Wet Unit Weight: 137.4 Concrete Temperature: 86 Air Temperature: 81 Test Date: 07/14/11 Time Test Taken: 2:36 PM Design
Strength: 5000 Amount of Water Added at Site: 5 Remarks: Set No. 64 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado inch(es) % pcf °F °F psi at 28
days gallons *Refer to ASTM C39/C39M-05 Age (days) Total Load (lbs) Diameter (in.) Area (sq. in.) Compressive Strength (psi) Type of Fracture* Tom Kassmel, P.E. 1309 Elkhorn Drive Vail,
CO 81657 Town of Vail, Department of Public Works/Transportation 7 44221 4.01 12.63 3500 2 28 62500 3.99 12.50 5000 2 28 68141 4.00 12.57 5420 2 28 67900 4.00 12.57 5400 Average: 5270
2