Loading...
HomeMy WebLinkAboutB11-0319NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWN O Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: 811 -0319 Job Address: 770 POTATO PATCH DR VAIL Location......: UNIT 6 Parcel No....: 210106319006 OWNER DONALD LANPHERE 770 POTATO PATCH DRIVE UNIT 6 VAIL CO 81657 APPLICANT PAINTING BY JESSE LLC PO BOX 6581 AVON CO 81620 License: C000003093 CONTRACTOR PAINTING BY JESSE LLC PO BOX 6581 AVON CO 81620 License: C000003093 09/07/2011 Phone: 847-858-8804 09/07/2011 Phone: 970-376-1031 09/07/2011 Phone: 970-376-1031 Project #: Applied.....: Issued... PRJ10 -0821 09/07/2011 09/16/2011 Description: REMOVE GARAGE STORAGE, ADD STAIRCASE TO CRAWLSPACE, UPDATE ELECTRICAL FOR HEAT Occupancy: Type Construction: Valuation: $51,000.00 ........ ............................... ........ ............................... FEE SUMMARY ...............,............................. ........................,...... Building Permit ------ - - - - -> $650.75 Bldg Plan Check ----- - - - - -> $422.99 Use Tax Fee------------------ - - - - -> $820.00 Electrical Permit ---- - - - - -> $115.00 Elec Plan Check ------ - - - - -> $74.75 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $852.00 Will Call ------------------------------ > $10.00 TOTAL PERMIT FEES --- ---------- > $3,146.74 Payments -- ---------------------------- > $3,146.74 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHA L BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 P Signature of Owner or Contractor Dat Print Name combination permit_012811 OVATUL TOWN CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0319 Owner: DONALD LANPHERE UNIT 6 combination permit_012811 Address: 770 POTATO PATCH DR VAIL Location: TOWN OF OVWL REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0319 Owner: DONALD LANPHERE UNIT 6 Address: 770 POTATO PATCH DR VAIL Location: Item: 00120 ELEC -Rough Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00060 BLDG - Sheetrock Nail Item: 00190 ELEC -Final Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110001236 Amount: $2,602.28 09/16/201112:34 PM Payment Method:Credit Crd Init: LC Notation: CREDIT CARD FROM JESSE L NIETO, PAINTING BY JESSE ----------------------------------------------------------------------------- Permit No: 1311 -0319 Type: COMBINATION BLDG PERMIT Parcel No: 2101- 063 - 1900 -6 Site Address: 770 POTATO PATCH DR VAIL Location: UNIT 6 Total Fees: $3,146.74 This Payment: $2,602.28 Total ALL Pmts: $3,146.74 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- BP - - - - -- 00100003111100 ------ ------------------ - - - - -- BUILDING PERMIT FEES ------ - - - - -- 650.75 PF 00100003112300 PLAN CHECK FEES 68.28 PN 00100003153000 INVESTIGATION FEE (BLDG) 1,053.25 UT 11000003106000 USE TAX 4% 820.00 WC 00100003112800 WILL CALL INSPECTION FEE 10.00 TOWN OF VAIL, COLORADO Statement ***#**#*****####**####*##**********###*#***********#####***** # # # # * * * * # # # # * * * # # # * * * * * * * * * * * ** Statement Number: R110001160 Amount: $544.46 09/07/201101:46 PM Payment Method:Credit Crd Init: LC Notation: CREDIT CARD FROM JESSE L. NIETO, PAINTING BY JESSE ----------------------------------------------------------------------------- Permit No: Bit -0319 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 063 - 1900 -6 Site Address: 770 POTATO PATCH DR VAIL Location: UNIT 6 Total Fees: $2,093.49 This Payment: $544.46 Total ALL Pmts: $544.46 Balance: $1,549.03 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- EP 00100003111100 ELECTRICAL PERMIT FEES 115.00 PF 00100003112300 PLAN CHECK FEES 429.46 BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street d ess t 770 ��� (Number) (Street) (Suite #) Building /Complex Name: yC��G�T'� P Project #: �s �Q —(�Z fi DRB #: Building Permit #: 7 1p Lot #: Block # Subdivision: Contractor Informat) n Business Name: .,,�� �� b � L-�C- Work Class: New ( ) Addition ( ) Alteration ( ) Business Address: / 1 4 ISK City l�Or� State: too Zip: �IC Zr) Type of Building: Single-Family( ) Duplex (� Multi - Family ( ) r -- Contact Name: � �Sf Cr �� � Commercial ( ) Other( ) Work Type: Interior (x) Exterior( ) Both( ) Contact Phone: ^ / Contact E -Mail: _:z ;J_L✓y 1 op /y o (, 6i Valuation of Work Included Plans Included Work Contractor Registration Number: /J X A-r f2`, -� Electrical (})Yes ( )No ( )Yes ( )No � Mechanical ( )Yes ( )No ( )Yes ( )No Plumbing ( )Yes ( )No ( )Yes ( )No Building (MY es ( )No ( )Yes ( )No 7 �� wner's Representative Signature (R quired) Project Information Owner Name: Parcel #: (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us/patie) Value of all work being performed: $ (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage /� p Detailed Scope and Location of Work: (use additional sheet if necessary) For Office Use Only- Fee Paid: �144• Date Received: 0 `1, UJ SEP 0 7 2011 L e, Received From. S,S e �. i e % � Cash Check # CC: Vis 7/MC Last 4 CC # exp date: 3 Auth # TOWN OF VAIL 01 -Jan -I I State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testinci required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two - Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single - family dwelling: any dwelling unit that is used primarily for a single family, including multi - family /condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State - certified abatement contractor. The air clearance letter or form must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: Will not disturb more than the threshold limits identified above. Tested negative, or at 1% or below (1 copies of test results included) Tested positive at more than 1 %, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos - containing materials, so buildings of gny age require testing. • The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos - containing product categories was set aside and did not take effect." - CDPHE Asbestos test results should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire _ inspectors @vai Igov.com 970 - 479 -2252 www.vailciov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303 - 692 -3158 asbestos@state.co.us wv,fw.cdphe.state.co.us 01- Jan -11 Health HealthSafe Inspections Inc 1052 Vine St Aspen CO 81611 970 - 920 -2100 Jim Baker, ACAC Board Certified CIE, CMRS, CMI, CSDS CDPHE Asbestos Building Inspector Certification #13437 ASBESTOS REPORT 09/06/2011 Painting by Jesse, LLC (Contractor) Don & Amy Lanphere (Condominium Owner) 770 Potato Patch Dr, #6 Vail, CO 81657 WTI) 904 :'_461/;30 @t-11 �Mll 770 Potato Patch Drive, #6, Vail, Colorado 81657 �K•]�•];7•�• • :.. • ; • • ► lulu • ; Colorado State Regulation 8 requires a State certified Asbestos Building Inspector to inspect and sample for suspect asbestos containing materials (ACM) prior to the disturbance, removal or demolition of more than 32 square feet of surfacing materials (e.g., drywall and associated textures, acoustic sprays and joint compounds), 50 feet of asbestos covered/insulated pipe or materials which would fill a 55 gallon drum. The regulations require a minimum of 3 samples per homogenous suspect material for up to 1,000 square feet of surface, and more samples beyond 1,000 square feet, etc.. In order for the contractor to proceed with restoration, renovation or demolition the suspect materials have to be sampled and analyzed by a NVLAP accredited laboratory by polarized light microscopy PLM methods. The Client needs to remove and renovate code violation installations in the garage and crawlspace. In order to perform this work an asbestos building inspection was necessary prior to any removal of suspect ACM. An inspection was conducted by Jim Baker of HealthSafe Inspections, Inc. during the afternoon of Thursday, August 25, 2011. Suspect materials which would be disturbed during the demolition in the garage and the remodel/renovation in the crawlspace were sampled. The materials covering more than 32 square feet but less than 1,000 square feet of homogenous surfacing material were identified requiring a minimum of 3 samples in the garage and 6 samples in the crawlspace and hatch closet due to two different dates of installations with two different textures and suspect joint compounds totaling 9 all together. There was no vinyl flooring, caulking, adhesives or other suspect building materials which would be disturbed. in 1. lt"MIXAW�� The bulk samples were analyzed by PLM by a NVLAP accredited laboratory in accordance with Colorado State Regulation 8 for the presence of asbestos mineral fibers. All 9 randomly distributed samples from the garage and crawlspace were: NONE DETECT See supporting Reservoirs Environmental, Inc. data: report # 219547 -1. All drywall and applied textures and joint compounds in the garage installation and crawlspace hatch closet and substructure area can be removed and disposed of in any landfill as normal construction debris. No asbestos abatement is necessary. Sincerely Submitted, Jim Baker Current Certifications: Colorado Asbestos Building Inspector ( #13437) http: / /www.cdphe.state.co.us/ap /asbestos /index.html American Council for Accredited Certification Board Awarded Certifications: 1. Council - Certified Mold Remediation Supervisor (CMRS) 2 2. Council- Certified Microbial Investigator (CMI) 3. Council- Certified Indoor Environmentalist (CIE) 4. Council - Certified Structural Drying Supervisor (CSDS) h!W: / /www.acac.or2 REI �Re Fervoirs Environmental, Inc. September 6, 2011 Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 219547 -1 Project # / P.O. # Lanphere Project Description: 770 Potato Patch #6, Vail Jim Baker Health Safe Inspections 1052 Vine St. Aspen CO 81611 Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program ( NVLAP), Lab Code 101896 -0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 219547 -1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303 - 964 -1986. Sincerely, Jeanne Spencer Orr President Analyst(s): Paul D. LoScalzo Michael Scales Anita Grigg Bethany Nichols Anya Angst Wenlong Liu Adam Humphreys Robert R. Workman Jr. Jennifer Jones P: 303 -964 -1986 5801 Logan Street, Suite 100 Denver, CO 80216 1- 866 -RESI -ENV F: 303 -477 -4275 www.reilab.com Page 1 of 3 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896 -0 TDH Licensed Laboratory # 30 -0136 TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O. Client Project Description: Date Samples Received: Analysis Type: Turnaround: Date Analyzed: RES 219547 -1 Health Safe Inspections Lanphere 770 Potato Patch #6, Vail August 26, 2011 PLM, Short Report 3 -5 Day September 2, 2011 Page 2 of 3 Client Sample Number a ID Number L A Sub Y Physical Part E Description ( %) R Mineral i Visual ; Estimate (% Non Asbestos Fibrous Components on- Fibrous Component N GARDRYWL -1 EM 787242 A Gray /brown drywall 100 ND 20 80 GARDRYWL -2 EM 787243 A Gray /brown drywall 100 ND 15 85 GARDRYWL -3 EM 787244 A Gray /brown drywall 100 ND 20 80 CRWLJT -1 EM 787245 A White tape 10 ND 90 10 B White compound w/ gold paint 10 ND 0 100 C Brown /white drywall 40 ND 50 50 D White compound 40 ND 0 100 CRWLJT -2 EM 787246 A White compound w/ white paint 2 ND 0 100 B White compound 2 ND 0 100 C White tape 3 ND 90 10 D White compound w/ tan paint 4 ND 0 100 E White /brown drywall 89 ND 20 80 CRWLJT -3 EM 787247 A White compound w/ gold paint 15 ND 0 100 B White tape 15 ND 90 10 C White compound 15 ND 0 100 D Brown /white drywall 55 ND 60 40 w ND =None Detected TR= Trace, < I % Visual Estimate Trem- Act= Tremolite- Actinolite Note: Further analysis by TEM is recommended for organically bound material (i.e. floor tile) if PLM results are <I %, Data QA� RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896 -0 TDH Licensed Laboratory # 30 -0136 TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O. Client Project Description: Date Samples Received: Analysis Type: Turnaround: Date Analyzed: RES 219547 -1 Health Safe Inspections Lanphere 770 Potato Patch #6, Vail August 26, 2011 PLM, Short Report 3 -5 Day September 2, 2011 Page 3 of 3 Client Sample Number a ID Number L A Sub Y Physical Part E Description ( %) R low Mineral visual 1 Estimate (% Non Asbestos Fibrous Components on- Fibrous Components ( %) CLSTJT -1 EM 787248 A White compound 2 ND 0 100 B White tape 3 ND 90 10 C White compound w/ white paint 4 ND 0 100 D White /brown drywall 91 ND 15 85 CLSTJT -2 EM 787249 A White compound 5 ND 0 100 B White tape 10 ND 90 10 C White compound w/ white paint 10 ND 0 100 D White /brown drywall 75 ND 25 75 CLSTJT -3 EM 787250 A White tape 2 ND 90 10 B White compound 3 ND 0 100 C White compound w/ white paint 4 ND 0 100 D White /brown drywall 91 ND 15 85 ND =None Detected TR= Trace,. <I %Visual Estimate , Trenr Act= Tremol ite- Actinolite Note: Further analysis by TEM is recommended for organically bound material (i.e. floor tile) if PLM results are =1 %. Data QA Due Date: Due Time: (n- 5801 Login SL Denvor. CO e021G • Ph..^-g3 56a1188 - Fax 303477 275 • Toll Frco 8W RESI•ENV Pager: 303.509 -2098 RES 219547 JOD IF Page 1 of _I rr vrrrcr�cty t Com_pany: t y: kP CONTACT INFORM ATION: Clotonnmoa cooa: Aodroa Addra s �-- I- J!1C�r• _ � : .� n5 .�Op_ w_ �% % O��i,�= 4� Phom: Fatc FmC Projoa Number andlor P.O. s; ._ r,� Colvpwr. i' - 366 Ej� F,nnt CcWpvQar. CJ�I a s r -- Prolog OosalptbNLacalbn; ,7 D Oala Dobwrnblo EmoA 141oross: C b�tiker d-) S C'E ris.nc ASBESTOS LABORATQRY HOURS: Weekda s: 7am - 7 m REQUESTED ANALYSIS VALID MATRIX CODES PLM /PCM / TEM RUSH (Same Day) ^ PRIORITY (Next Day) STANDARD I LAB NOTES: (Rush PCM - 2hr, TEM s $hr.) ! I Air = A Bulk a B CHEMISTRY LABORATORY HOURS: Weekda s: Sam - 5 m Oust ■ 0 1 Paint = P Metal(s) J Oust _ RUSH _ 24 hr. -__,3 -5 Day Soil ■ S Wipe = W RCRA 8 / Metals & Welding "Prior notification Is 1 c Swab = SW F =Food Fume Scan/ TCLP — RUSH _„ 5 day _10 day roquirod for RUSH O - Drinking Water = DW Wasto Water = WW turnarounds. Organics _ 24 hr, ,__ 3 day __5 Day v c 'b * a y a ; W O 0= Other "ASTM E 1792 MICROBIOLOGY LABORATORY HOURS: Weekdays gam - 6pm a a " m m o w approved wipe modal only E.coli 0167:H7, Coliforms, Saureus _ 24 hr. _2 Day _ 3-B Day Salmonella, Q g E g Listeria, E.coli, APC, Y $ M _ a8 Hr, ,_•3 -5 Day ^ to o Mold !RUSH 24 Hr 48 Hr 3 D 5 Day "'Yvrnuround ++++ g appsi a w I ;' o a O O iS I dmus vttabllnh a t ;.borrtory Pnorlty. Subjeotto lobvrntoty volufno and nro not puarante.^.Q Addrtlonel rvoa aPPly for att9rhoum, viuc kenda and holidays.•' Special Instructions: T �i to ro r o ^ + • . bb� ; $ c tc z o ¢= d 8 °s 'o @ at d V �g , Date Time EM Nurnber(Labomlory Client sample ID number (Sample ID's must be unique) w a a a a tnuiO <uivyri� Q O a x c E< S O td •• m u Collected Collected UsoOnry) a ►W MICROBIOLOGY a% -1 y ... � 7L mMdotyy hhlmm alp z A �•D R,(%,j s•--- 2— s 4 C R W i_ _ J j I 1 j r-j 5 P, V., T-2- ( 1 L{ S 1 17— L{ ? t g L Z 4 a 9 C. L_�! - LE S G Number of samples received; 4-1 J NOTE RE! vd11 analyze Incoming ur pies bsaa n info n rdoolvod and wig nol be rosoonsiblo for errors er emissions In ratr.u,r - ......m._ .__ ,._ .____...__. __:_,_ _. —am or custody snau constitute an oroytimlyervises ogreomenl vdlh payment terms or NET 30 deys, allure to aomply with _ - _ - - -� aurora nor suotns*m m W rolla" samples for roquoated payment loans -W rosult In a 1.5% monthly Intorost suA;Nvgc. in uished B L r �! Date/Time: ✓rf Sample Condition: On Ice Sealed et )oratory Use Only // ( C'2.1c , ✓. eived By: !/' �.. _ .•L, lTime: L ' t ( C Temp. (F% Yes / N Date o Yes / No Y /No t•= �!_c =C �'--�C Its: Contact Phone Email Fax Date Time Initials Contact Phone Email Fax Date Tima Initials Contact Phone Email Fax Date Tfmn InA;etc r•....,.._. „�___ _ .. _ 7-2011—version 1 CC) -)cTeCi�,� TOTAL EAST WALL AT CRAWLSPACE OVER 5' TALL =122 S.F. AREA OF CRAWL SPACE WALL COVERED BY GRADE =72 S.F UPPER LEVEL MASTER SUITE 483 sq. ft. LI cr s c re s er b gr e th ex lore i TOTAL WEST WALL AT CRAWLSPACE OVER STALL =217 S.F. AREA OF CRAWL SPACE WALL COVERED BY GRADE /UNIT 5 =217 S.F. I TOTAL NORTH WALL AT CRAWLSPACE OVER 5' TI LL =200 S.F. AREA OF CRAWL SPACE WALL COVERED BY G DE =200 S.F. AVERAGE HEIGHT AT — — WALL — TOTAL SOUTH WALL AT CRAWLSPACE OVER 5'rALL =200 S.F. AREA OF CRAWL SPACE WALL COVERED BY G DE =71 S.F. 11 IN7. Upper Level Area = 705 s.f. STORAGE % 17 sq. ft. SITTING AREA /LANDING 97 sq. ft. I Crawll Space over 5-0" tall Area 615 s.f. with 75% reduction for below grade adjusted Crawlspace area = 153.75 s.f. TOTAL WALL SURFACE =739 S.F. TOTAL WALL SURFACE =560 S.F. CRAWLSPACE AREA REDUCTION OF 75% � v _�- �''� Total GRFA Area = ,v Total Garage AL = I SUMMARY GARAGE 369 sq. ft. I I ROOM II TO BE II REMOVED I I Garage Level Area = 416 s.f. Upper Level Area= Main Level Area = Lower Level Area = Adjusted Crawlspace area= 1UNIT45 UNFINISHED CRAWLSPACE 516 saa ft. FINISHED LADDER 0 sq. ft FINISHED CRAWL SPACE 194 sq. ft. UN 51 INISHED ALSPACE sq. _ft_ 705 s.f. 925 s.f. 818 s.f. 153.75 s.f. 2,601.75 s.f. 416 s.f. Crawl Space over 5' -0" tall Area = 615 s.f. Main Level Area = 925 s OFFICE/ , TOW ,L 14;4 LANDING /\ REVIEWED FOR CODE 48 sq. ft./ ��ti�J COMFLIA G i Date: pill By: L. Code: ,�9 LOWER LEVEL 758 sq. ft. " 0 W J Z W Q LL od LU C U� .LW ° fir E ff o a U o �P: X11 J wN N LLJ in J a o �' CD o °' 0 2 V a Z ° wo> N CV I.P., 0 w U) W F— _J Sunken Lower Level N Bedroom Area = 818 s. CD G FA CALCULATION SHEET Q 4 UNIT #5 1 UNIT #6 CRAWLSPACE EXISTING SHIPS LADDER TO BE REMOVED - 11' -0» 6' -11" 5' -11J" PARTY WALL STAIR 2 '?\t 2' -4j„ UNIT #5 I UNIT #6 EGRESS WINDOW SILL @ 40 "' A.F.F. Parcel Number 2101- 063 -19 -006 Tax Area SC103 - VAIL (TOWN) - SC1 3 Situs Address 000770 POTATO PATC DR #6 Legal Summary Subdivision: 770 POTATO PATCH DRIVE CONDO Unit: 6 Owner Name LANPHERE, ANN MARIE & DONALD J. Owner Address 1741 E RIDGEWOOD LN GLENVIEW, IL 60025 CRAWLSPACE Ln N 2'- 1 N" Architect: Jeffrey P Manley AIA (CO Lic # 400519) Martin Manley Architects PO box 1587 Eagle, CO 81631 Phone: 1- 970 - 328 -5151 e -mail: jeff@martinmanleyarchitects.com CODE: 2009 IBC Type of Construction V -N Type of Occupancy: R2 Q0 i N I i Ln } W z QN O Od LL OL F � W� GO O� JEFF Y P ANLEY Z °� i Q m E �- 01 r 40 519 Q D AR BUILDING OUTLINE 1 VERIFY CRAWLSPACE VENTILATION REQUIREMENTS FOR CRAWLSPACE AREA UNDER UNIT 6. PROVIDE 1 S.F. VENTILATION OPENINGS FOR EACH 150 S.F. OF CRAWLSPACE. AREA OF UNFINISHED CRAWLSPACE= 521 S.F. 521/150 = 3.47 S.F. OF OPENING ALTERNATE IS TO PROVIDE MECHANICAL VENTILATION FAN TO MEET REQUIREMENTS THE FINISHED CRAWLSPACE DOES NOT NEED VENTILATION 2 ACCESS VIA THE STAIR MINIMUM SIZE IS 18 "x24" 3 THE FLOOR ABOVE THE CRAWLSPACE SHALL HAVE A MINIMUM INSULATION R -VALUE OF 30 4 THE DIRT WITHIN THE UNFINISHED n Oj Ua� CRAWL PACE AREA IS TO BE A MINIMUM �pW LOW THE TOP OF CONCRETE UNDATION WALLS AND CONCRETE COMPLY ERIOR STEM WALLS. CORRECT THE INa°AR&OND THE INTERIOR WOOD ®ate FRAMED UMNS Code CRAWLSPACE LEVEL (D SCALE: 1 /4' �' -0" Z ° m w z W U z C LD J 2 o ^cn W C7 t o U) <am �(Doom L o co L) a o Z a .@ > �a CL J � U 0 N a 0 o a ' 1' -4 WITHIN THE THE - VERIFY EXISTING HEADER IS FINISHED CRAWLSPACE, '- ADEQUATELY SUPPORTED AND THE EXISTING DRYWALL SPAMS OPENING BEFORE WALLS IS TO BE REMOVED ARE REMOVED. ADEQUATELY TO PROVIDE VERIFICATION / INSPECTION BY THE BUILDING OFFICIAL FOR Finished crawlspace CONFORMITY TO 2009 IBC AND ELECTRICAL CODE. UNIT #5 I UNIT #6 EGRESS WINDOW SILL @ 40 "' A.F.F. Parcel Number 2101- 063 -19 -006 Tax Area SC103 - VAIL (TOWN) - SC1 3 Situs Address 000770 POTATO PATC DR #6 Legal Summary Subdivision: 770 POTATO PATCH DRIVE CONDO Unit: 6 Owner Name LANPHERE, ANN MARIE & DONALD J. Owner Address 1741 E RIDGEWOOD LN GLENVIEW, IL 60025 CRAWLSPACE Ln N 2'- 1 N" Architect: Jeffrey P Manley AIA (CO Lic # 400519) Martin Manley Architects PO box 1587 Eagle, CO 81631 Phone: 1- 970 - 328 -5151 e -mail: jeff@martinmanleyarchitects.com CODE: 2009 IBC Type of Construction V -N Type of Occupancy: R2 Q0 i N I i Ln } W z QN O Od LL OL F � W� GO O� JEFF Y P ANLEY Z °� i Q m E �- 01 r 40 519 Q D AR BUILDING OUTLINE 1 VERIFY CRAWLSPACE VENTILATION REQUIREMENTS FOR CRAWLSPACE AREA UNDER UNIT 6. PROVIDE 1 S.F. VENTILATION OPENINGS FOR EACH 150 S.F. OF CRAWLSPACE. AREA OF UNFINISHED CRAWLSPACE= 521 S.F. 521/150 = 3.47 S.F. OF OPENING ALTERNATE IS TO PROVIDE MECHANICAL VENTILATION FAN TO MEET REQUIREMENTS THE FINISHED CRAWLSPACE DOES NOT NEED VENTILATION 2 ACCESS VIA THE STAIR MINIMUM SIZE IS 18 "x24" 3 THE FLOOR ABOVE THE CRAWLSPACE SHALL HAVE A MINIMUM INSULATION R -VALUE OF 30 4 THE DIRT WITHIN THE UNFINISHED n Oj Ua� CRAWL PACE AREA IS TO BE A MINIMUM �pW LOW THE TOP OF CONCRETE UNDATION WALLS AND CONCRETE COMPLY ERIOR STEM WALLS. CORRECT THE INa°AR&OND THE INTERIOR WOOD ®ate FRAMED UMNS Code CRAWLSPACE LEVEL (D SCALE: 1 /4' �' -0" Z ° m w z W U z C LD J 2 o ^cn W C7 t o U) <am �(Doom L o co L) a o Z a .@ > �a CL J � U 0 N a 0 o a A N LEVEL ENTRY 07 sq. ft,% .,o xll" 1/. �owr+ of Vail REVIEWED F OR CODE COMPLI Date: By. �4 ;ode: ----- MAIN LEVEL 750 sq. ft. 00 9 pr J- 400519 SFD ARG� 04- RT.EE.VEL DEMOLITION PLAN E: = 1' -0, } W J E Z m w m Q 0' O O m F LL u 5L O .2 W a ;, m Z E • � M �.. Q m $ E O N a 0 Z 0 a� U o J 2 *o �05 o NNW z� 4' I..V C7 U O � (6 N (D (D O 0 a m o z .@ U a o> � Q CL co � J q a N O O N Q e o a N L -- MAIN LEVEL ELEV. = 8488.9' aS i NEW SPIRAL STAIR,-1 BEDROOM ELEV. = 8478.7' FINISHED CRAW SPACE C54 d- T UPPER ELEV. = 8501.5.1' CRAWL SPACE ENTRY ELEV. = 8493.1' GARAGE ELf . = 8491.7' OFFICE LANDING LOWER ELEV. = 8480.2' Town of Vail REVIEWED FOR COut COMPLIA 1 1' Date: By: 0 Cod e. GO JEF P JNLEY 40 5 9 IL �F AR 0 BUILDING SECTION SCALE: 1 /4" m 1' -0" } W J E z m� w ` " LL U L 2 OJ •z�� a Q m $ E f" a Q N Z 0 QZ 0 (�1 J (� o NW 0 L (n CE cc Qa- 0 @U s—ZO_ a C— w Q U c J J � U N N O M .o P a 01 -09 -2012 Inspection Request Re orting / Page 3 4:32 pm Vail, CO C ty Of � � 21 Requested Inspect Date: Tuesday January 10, 2012 Site Address: 770 POTATO PATCH DR VAIL UNIT 6 A/P /D Information Activity: Bl l -0319 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: DONALD LANPHERE Phone: 847 - 858 -8804 Contractor: PAINTING BY JESSE LLC Phone: 970 - 376 -1031 Description: REMOVE GARAGE STORAGE, ADD STAIRCASE TO CRAWLSPACE, UPDATE ELECTRICAL FOR HEAT Requested Inspection(s) Item: 90 BLDG -Final Requestor: PAINTING BY JESSE LLC Comments: 376 -10 1 Assigned To: AGON Action: Time Exp: Item: 190 ELEC -Final Requestor: PAINTING BY JESSE LLC Comments: 376 -1031 Assigned To: J ON Action: Time Exp: Inspection Histo Item: 120 ELEC -Rough ** Approved ** 10/17/11 Inspector: sgremmer Comment: Item: 30 BLDG - Framing ** Approved ** 10/10/11 Inspector: Martin Comment: Provide electrical inpsection Garage ok 10/17/11 Inspector: sgremmer Comment: Item: 50 BLDG - Insulation ** Approved ** 10/17/11 Inspector: sgremmer Comment: Item: 60 BLDG - Sheetrock Nail ** Approved ** 10/18/11 Inspector: sgremmer Comment: Item: 190 ELEC -Final Item: 90 BLDG -Final REPT131 Requested Time: 08:30 AM Phone: 970 - 376 -1031 Entered By: JMONDRAGON K Requested Time: 08:00 AM Phone: 970 - 376 -1031 Entered By: JMONDRAGON K Action: AP APPROVED Action: DN DENIED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Run Id: 14014