Loading...
HomeMy WebLinkAboutF11-0046 VK462mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data April 8, 2011 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com 1. description Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for instal- lation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to ½” (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling fin- ish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. listings and approvals cUlus listed: Category VNIV Fm approval: Class 2015 nYc approved: MEA 89-92-E, Volume 32 vds approved: Certificate G4080021 lpcB approved: Ref. No. 096e/12 ce certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 Refer to Approval Chart 1 and Design Criteria on page 54c for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 54d for FM Approval requirements that must be followed. 3. technical data Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* maximum Working pressure: sprinkler vk463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. high-pressure (hp) sprinklers can be identified by locating “250” stamped on the deflector. sprinkler vk462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric†) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimumoperatingpressureforLPC��andCEinimum operating pressure for LPC�� and CE Approvals ONLY is 5 psi (0.35 bar). †Metric K-factor measurement shown is when pressure is measured in ��ar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. material standards: Sprinkler ��ody: ��rass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor ��ronze UNS-C51000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy ��ulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 ��utton: ��rass UNS-C36000 Screws: 18-8 Stainless Steel ��elleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor ��ronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-f, dated February 25, 2011. (Revised LPC�� Approval. Removed UL listing from 165 °F Cover 15394. Obsoleted sprinkler 14697.) viking technical data may be found on the viking corporation’s Web site at http://www.vikinggroupinc.com. the Web site may include a more recent edition of this technical data page. Sprinkler 54a technical data April 8, 2011 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) cover assembly materials: Cover: Copper UNS-C11000 ��ase: ��rass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic ordering information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: sprinkler: ��ase Part No. 13503A or HP ��ase Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155°/68° = ��, 175°/79° = D, 200°/93° = E For example, sprinkler VK463 with a 155°F/68°C temperature rating = 13667A��. cover plate assembly: ��ase Part No. 13504 (2-3/4” diameter), ��ase Part No. 13642 (3-5/16“ diameter), or ��ase Part No. 15394 (square cover plate, 3-5/16” diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, ��rushed Chrome = F-/��, ��right ��rass = ��, Antique ��rass = ��-/A, ��rushed ��rass = ��-/��, ��rushed Copper = E-/��, Painted White = M-/W, Painted Ivory = M-/I, Painted ��lack = M-/�� Temperature Suffix (°F/°C): 135°/57° UL (139°/59° FM and LPC��) = A, 165°/74° = C For example, cover 13504 with a Polished Chrome finish and a 165°F/74°C temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135°F (57°C) temperature rated cover plate only. Refer to the Approval Chart. available Finishes and temperature ratings: Refer to Table 1. accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/�� (available since 2006), or ��. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. sprinkler cabinet: Part No. 01731A (available since 1971) 4. installation Refer to appropriate NFPA Installation Standards. 5. operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availaBilitY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. gUarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 54b mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data April 8, 2011 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com taBle 1: availaBle sprinkler temperatUre ratings and Finishes sprinkler temperature classification sprinkler nominal temperature rating1 maximum ambient ceiling temperature2 temperature rating of cover assembly (required)Bulb color Ordinary 155°F (68°C)100°F (38°C)135°F (57°C) cULus 139°F (59°C) FM and LPC��Red Intermediate 175°F (79°C)150°F (65°C)165°F (74°C)Yellow Intermediate 200°F (93°C)150°F (65°C)165°F (74°C)Green cover plate Finishes: Polished Chrome, ��rushed Chrome, ��right ��rass, Antique ��rass, ��rushed ��rass, ��rushed Copper, Painted White, Painted Ivory, or Painted ��lack Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 ��ased on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinkler 54c Figure 1: identification of custom paint color for concealed covers Figure 2: square cover assembly 15394 technical data April 8, 2011 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) Sprinkler 54d design criteria - Ul (Also refer to Approval Chart 1 above.) cUlus listing requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. note:concealedsprinklersmustbeinstalledinneutralornegativepressureplenumsonly.ote: concealed sprinklers mustbeinstalledinneutralornegativepressureplenumsonly.ust be installed in neutral or negative pressure plenums only. • • • • • • important: always refer to Bulletin Form no. F_091699 - care and handling of sprinklers. also refer to page sr1-3 or Qr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in accordance with the latest edition of viking technical data, the appropriate standards of nFpa, lpcB, apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. approval chart 1 (Ul) mirage® concealed pendent sprinklers vk462 and vk463 sprinkler Base part no.1 sin npt thread size nominal k-Factor maximum Water Working pressure listings and approvals4 (refer also to design criteria below.) inch mm U.s.metric2 cUlus5 nYc vds lpcB standard response applications 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)----AY1, CZ1 AY1, ��Z1 AY1, CZ17 Quick response applications 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AV1, ��X1 AV1, ��W16 ------ 13667A VK463 1/2”15 5.6 80.6 250 psi (17.2 bar)3 AV1, ��X1 AV1, ��W16 ------ sprinkler temperature ratings A - 155°F (68°C) �� - 175°F (79°C) and 200°F (93°C) C - 200°F (93°C) cover plate assembly temperature ratings8 V - 135°F(57°C)cULusListedcover13504135°F (57°C) cULus Listed cover 135041, 136421 (large diameter), or 153941 (square cover plate) W - 165°F (74°C) cover 135041 or 136421 (large diameter) X - 165°F(74°C)cover13504165°F (74°C) cover 135041, or 136421 (large diameter) Y - 135°F (57°C) cover 135041 LPCB Approved as 139°F (59°C) Z - 165°F (74°C) cover 135041 cover plate assembly Finishes9 1 - Polished Chrome, ��rushed Chrome, ��right ��rass, Antique ��rass, ��rushed ��rass, ��rushed Copper, Painted White, Painted Ivory, or Painted ��lack Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in ��ar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 The Water Working Pressure rating is stamped on the deflector. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of ��uildings, MEA Number 89-92-E, Vol. 32. 7 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 The 135/139 °F cover has an orange label. The 165 °F cover has a white label. 9 Painted finish consists of Polyester ��aked Enamel. Otherpaintcolorsareavailableonrequestwiththesamelistingsasthestandardpaintcolors.Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data April 8, 2011 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com Sprinkler 54e design criteria - Fm (Also refer to Approval Chart 2 above.) Fm approval requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response non-storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. note: the Fm installation guidelines may differ from cUlus and/or nFpa criteria. important: always refer to Bulletin Form no. F_091699 - care and handling of sprinklers. also refer to page sr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in ac- cordance with the latest edition of viking technical data, the appropriate standards of nFpa, Fm global, lpcB, apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. approval chart 2 (Fm) mirage® standard response concealed pendent sprinkler vk462 sprinkler Base part no.1 sin npt thread size nominal k-Factor maximum Water Working pressure Fm approvals3 (refer also to design criteria below.)inch mm U.s.metric2 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AW1, ��X1 sprinkler temperature ratings A - 155°F (68°C) �� - 175°F (79°C) and 200°F (93°C) cover plate assembly temperature ratings4 W - 139°F(59°C)cover13504139°F (59°C) cover 135041, 136421 (large diameter), or 153941 (square cover plate) X - 165°F(74°C)cover13504165°F (74°C) cover 135041, 136421 (large diameter), or 15394153941 (square cover plate) cover plate assembly Finishes5 1 - Polished Chrome, ��rushed Chrome, ��right ��rass, Antique ��rass, ��rushed ��rass, ��rushed Copper, Painted White, Painted Ivory, or Painted ��lack Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in ��ar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 The 139°F cover has an orange label. The 165°F cover has a white label. 5 Painted finish consists of Polyester ��aked Enamel. Otherpaintcolorsareavailableonrequestwiththesamelistingsasthestandardpaintcolors.Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. technical data April 8, 2011 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) Form No. F_103005 Sprinkler 54f Figure 4: sprinkler dimensions and cover installation Figure 3: sprinkler installation and correct Use of Wrenches Replaces page 54a-f, dated February 25, 2011. (Revised LPC�� Approval. Removed UL listing from 165 °F Cover 15394. Obsoleted sprinkler 14697.)