HomeMy WebLinkAboutB11-0309 comment letter
Date: 9/08/2011
Re: 122 East Meadow Drive / B11-0309
Dear Mr. Loff,
RESPONSE INSTRUCTIONS
● Submit three complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified.
● Please respond in writing to each comment with a response letter addressing each comment.
BUILDING COMMENTS
Architectural Comments:
1. Plans to be fully dimensional and to scale per Town of Vail submittal requirements
2. Indicate Type of Building construction and proposed roof covering classification. Reference section 1505.1 IBC
3. Description indicates “PVC roof” please clarify materials and the associated ASTM standard to be used for the installation. Is this a thermoplastic roof system? See section 1507.13
IBC. Provide information on the plans.
4. Description on permit indicates a flat roof. A minimum of ¼” per foot slope is required or plans to be designed by a structural engineer to address potential ponding.
5. Show required roof drainage to include secondary drains per section 1503.4 IBC.
6. Indicate size of drains showing compliance with section 1503.4 IBC and the IPC.
PLANNING COMMENTS
Reviewed and accepted
FIRE COMMENTS
NA
PUBLIC WORKS COMMENTS
1. A right of way permit is required accompanied by a construction staging plan. To be submitted and approved prior to issuance of a building permit. Contact Leonard Sandoval at 479-2198
Sincerely,
Martin A. Haeberle
Chief Building Official