HomeMy WebLinkAboutA11-0048TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970 - 479 -2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT
Job Address: 68 E MEADOW DR VAIL
Location.....: VAIL VILLAGE INN PHASE 3 UNIT 301
Parcel No...: 210108254019
Project No
OWNER ENCHANTED MESA EXEMPT
C/O FREDERICK S. OTTO
PO BOX 3149
VAIL
CO 81658
APPLICANT COMMERCIAL SPECIALISTS
PO BOX 3913
EAGLE
CO 81631
License: 161 -S
CONTRACTOR COMMERCIAL SPECIALISTS
21 MARMOT LANE UNIT B5
EAGLE
CO 81631
License: C000003355
Desciption: INTERIOR REMODEL
Valuation: $5,610.00
CORP 09/13/2011
OF WE 09/13/2011
OF WE 10/10/2011
Permit #: A 11 -0048
Status ...:
ISSUED
Applied..:
09/13/2011
Issued . .:
10/10/2011
Expires. .:
04/07/2012
Phone: (970) 328 -1951
Phone: 970 - 328 -1951
************************************* * * * + * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * + * * * * * * **
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN AD VA_NF-E BY TELEPHONE AT 970- 479 -2252 FROM 5:00 AM - 5 PM.
SIGNATURE OF WNER OR CONTRACTOR FOR HIMSELF AND OWNEF
Electrical --------- >
$0.00
Total Calculated Fees - ->
$498.38
DRB Fee --------- >
$0.00
Additional Fees ---------- >
$0.00
Investigation ---- >
$0.00
Total Permit Fee--- - - - - ->
$498.38
Will Call --------- >
$0.00
Payments ------------------ >
$498.38
TOTAL FEES -->
$498.38
BALANCE DUE--- - - - - ->
$0.00
Approvals:
Item: 05600
FIRE DEPARTMENT
09/21/2011
mvaughan
Action: AP
CONDITIONS OF APPROVAL
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN AD VA_NF-E BY TELEPHONE AT 970- 479 -2252 FROM 5:00 AM - 5 PM.
SIGNATURE OF WNER OR CONTRACTOR FOR HIMSELF AND OWNEF
TOWN OF VAIL, COLORADO Statement
Statement Number: R110001437 Amount: $498.38 10/10/201102:41 PM
Payment Method: Check Init: SAB
Notation: 11179 - COMM.
SPECIALISTS OF WESTERN COL
-----------------------------------------------------------------------------
Permit No: All -0048 Type: ALARM PERMIT
Parcel No: 2101- 082 - 5401 -9
Site Address: 68 E MEADOW DR VAIL
Location: VAIL VILLAGE INN PHASE 3 UNIT 301
Total Fees: $498.38
This Payment: $498.38 Total ALL Pmts: $498.38
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
BP 00100003111100 FIRE ALARM PERMIT FEES 210.38
PF 00100003112300 PLAN CHECK FEES 288.00
of Community Development
75 South Frontage Road
Vail, Colorado 81657
Tel: 970 - 479 -2128,
Fax: 970- 479 -2452
Web: www.vailgov.com
lopment Re iv�e� ,Co rd n to ,
0", 01W
A A""
ALARM PERMIT
Commercial and Residential Fire Alarm shop drawings are required at the time of application
submittal and must included information listed on the 2nd page of this form. Application will
not be accepted without this information.
Project Street Address:
68 EAST MEADOW DRIVE 301
(Number) (Street) (Suite #)
Building /Complex Name: VAIL VILLAGE INN PHASE III
Contractor Information:
Company: COMMERCIAL SPECIALISTS
Company Address: 210 MARMOT LANE UNIT 135
City: EAGLE State: CO Zip: 81631
Contact Name: TIM WARD
Contact Phone: 970.328.1951
E -Mail TIM @CSWCFIRE.COM
Town of Vail Contractor Registration No.: S -161
Dl9i1a11y signed by Tim Ward
ON Ti, Ward, — COMMERCIAL SPECIALISTS, —NICET
Tim Ward IV 911594 TIM@CSIG1 COM, c =US
X Date: 2017 09.09 1151:45 -06'00'
Contractor Signature (required)
Property Information
Parcel #: 210108254019
(For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or
visit www.eaglecounty.us /patie)
Tenant Name: FRANCO RESIDENCE
Owner Name: FRANCO
Complete Valuation for Fire Alarm Permit:
Fire Alarm $: $5,610.00
Office Use: n
Project #:
Building Permit #: - ?)I
Alarm Permit #: A / l �
Lot #: Block # Subdivision:
Detailed Description of Work: ADDING SEVEN (7) NEVI
SMOKE DETECTORS AND FIVE (5) SPEAKERS
TO THE EXISTING NFS -640 FIRE ALARM
SYSTEM.
(use additional sheet if necessary)
Does a Fire Alarm Exist? Yes ( +) No( )
Does a Sprinkler System Exist? Yes ( +) No( )
Work Class:
New ( ) Addition ( ) Remodel ( +) Repair ( )
Retro -Fit ( ) Other ( )
Type of Building:
Single - Family ( ) Duplex ( ) Multi - Family (+ )
Commercial ( +) Restaurant ( ) Other ( )
Date Received: F N�SEP LE a W TE
0 9 7011
TOWN OF VAIL
29- May -09
FAPT- 851(A)
Acclimate@ PIusTM Multi- Sensor
DN- 6937:C
* NOTI FI E R"
Low - Profile Intelligent Detector by Honeywell
Intelligent/Addressable Devices
General
The Notifier FAPT- 851(A) Acclimate(g) PIusTm detector is an
intelligent, addressable, multi- sensing, low- profile detector
designed for use with Notifier Onyx and CLIP series Fire Alarm
Control Panels.
The Acclimate Plus detector uses a combination of photoelec-
tric and thermal sensing technologies to increase immunity to
false alarms. Unlike traditional intelligent detectors, the Accli-
mate Plus detector has a microprocessor in the detector head
that processes alarm data. As a result, the Acclimate Plus
detector adjusts its sensitivity automatically, without operator
intervention or control panel programming.
Areas where the Acclimate Plus detector is especially useful
include office complexes, schools, college campuses, manu-
facturing and industrial facilities, and anywhere else the use of
a particular area may change. The Acclimate Plus detector
automatically adjusts its sensitivity to the environment.
FlashScan (U.S. Patent 5,539,389) is a communication proto-
col developed to greatly enhance the speed of communication
between analog intelligent devices and compatible systems.
Intelligent devices communicate in a grouped fashion. If one of
the devices within the group has new information, the panel's
CPU stops the group poll and concentrates on single points.
The net effect is response speed greater than five times that of
earlier designs.
Features
• Automatically adjusts sensitivity levels without operator
intervention or programming. Sensitivity increases with
heat.
• Microprocessor- based, combination photo and thermal
technology.
• FlashScanO and CLIP system compatible (NFS -320, NFS -
640, NFS2 -640, NFS -3030 and NFS2 -3030)
• Addressable - analog communication.
• Sleek, low- profile design.
• Two -wire SLC connection.
• Direct -Dial entry of address: (1 — 159 on FlashScan sys-
tems; 1 — 99 on CLIP systems).
• Addresses can be viewed and changed without electronic
programmers.
• Dual bi -color LED design provides 360° viewing angle.
• LEDs lock red when in alarm. In FlashScan, LEDs flash
green in standby for normal condition.
• Built -in tamper- resistant feature.
• Constructed of off -white fire - resistant plastic, designed to
commercial standards, and offers an attractive appearance.
• SEMS screws for wiring of the separate base.
• Several base options, including relay, isolator, and sounder.
• Built -in functional test switch activated by external magnet.
• Listed to UL 268.
• Capable of heat -only alarm mode, enabled by a special
command from the panel. Smoke alarms are ignored.
• Low- temperature signal at 45 °F +/— 10 °F (7.22 °C +/-
5.54 °C).
6937Pno1.1P9i!I'
FAPT- 851(A) in B71OLP base (base ordered
separately)
Specifications
Sensitivity: auto - adjusting levels: 1 to 2 % /ft. and 2 to 4 % /ft.
with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4 % /ft. with
systems; fixed - sensitivity levels: 1, 2, and 4 % /ft. with classic
CLIP systems; 0.5, 1, 2, 3, and 4 % /ft. with FlashScan systems.
Size: 2.0" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in
B501 base, 6.1" (15.5 cm) diameter installed in B710LP base.
Shipping weight: 5.2 oz. (147 g).
Operating temperature: 0 °C to 38 °C (32 °F to 100 °F).
Operating altitude: up to 10,000 feet.
UL- Listed velocity range: 0 — 4000 ft. /min. (12192 m /min.),
suitable for installation in ducts.
Relative humidity: 10% — 93% noncondensing.
Thermal sensing rating: fixed - temperature setpoint 135 °F
(57 °C).
ELECTRICAL SPECIFICATIONS:
Voltage range: 15 — 32 volts DC peak.
Standby current (max. avg.): 300 pA.
Loop resistance: 50 ohms maximum; varies according to
control panel used. Refer to panel installation manuals.
LED current (max.): 6.5 mA Q 24 VDC (''ON ").
Installation
The FAPT- 851(A) plug -in detector uses a separate base to
simplify installation, service, and maintenance. A special tool
allows maintenance personnel to plug -in and remove detec-
tors without using a ladder. Suitable mounting base boxes
include:
4.0" (10.16 cm) square box.
3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box
Single -gang box (except relay or isolator base).
NOTE: The FAPT- 851(A) detector has the unique ability to adjust
sensitivity according to the environment, based on heat and
smoke levels. Avoid installing these detectors in locations that are
susceptible to rapid and high temperature changes. An example of
an incorrect application would be near or in line with the output of a
self - contained heater.
DN- 6937:C • 10/26/2010— Pagel of 2
Agency Listings and Approvals
These listings and approvals apply to the modules specified in
this. In some cases, certain modules or applications may not
be listed by certain approval agencies, or listing may be in pro-
cess. Consult factory for latest listing status.
• UL Listed: S1115
• ULC Listed: S1115
• MEA Listed: 225 -02 -E
• FM Approved
• CSFM:7272- 0028:0206
• U.S. Coast Guard: 161.002/42/1 (NFS -640)
• Lloyd's Register: 02/60007 (NFS -640)
• Maryland State Fire Marshal: Permit # 2122
Ordering Information
NOTE: "A" suffix indicates ULC Listed model.
FAPT -851: Low - profile intelligent multi- sensor detector. Must
be mounted to one of the bases listed below.
FAPT -851 A: Same as FAPT -851 but with ULC Listing.
INTELLIGENT BASES
B501 (A): Flangeless mounting base.
B200S(A): Intelligent sounder base capable of producing
sound output in high or low volume with ANSI Temporal 3,
ANSI Temporal 4, continuous tone, marching tone, and custom
tone.
B200SR(A): Intelligent sounder base capable of producing
sound output with ANSI Temporal 3 or continuous tone.
Replaces the B501 BH series bases in retrofit applications.
B710LP: Flanged mounting base. (6.1 ", 15.5 cm diameter)
B71OLPA: Flanged mounting base, ULC Listed.
B224RB: Relay base Screw terminals: up to 14 AWG (2.0
mm Relay type: Form -C. Rating: 2.0 A @ 30 VDC resistive;
0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive.
Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm)..
B224RBA: Relay base, ULC Listed.
B224BI: Isolator base. Dimensions: 6.2" (15.748 cm) x 1.2"
(3.048 cm). Maximum: 25 devices between isolator bases.
B224BIA: Isolator base, ULC Listed.
ACCESSORIES:
F110: Retrofit replacement flange for older high profile bases.
Converts bases for use with FlashScan@ detectors.
RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S.
single -gang electrical box. Supported by B710LP(A) and
B501 (A) bases only.
SMB600: Surface mounting kit for use with B710LP(A).
BCK -20OB: Black detector covers, box of 10.
MO2- 04 -00: Test magnet.
MO2- 09 -00: Test magnet with telescope stick.
XR2B: Detector removal tool. Allows installation and /or
removal of FlashScan@ Series detector heads from base in
high ceiling installations.
T55- 127 -010: Detector removal tool without pole.
XP -4: Extension pole for XR2B. Comes in three 5 -ft. sections.
Notifier0, ONYX (5, FlashScanO, and Acclimate@ are registered trademarks
and Acclimate Plus— is a trademark of Honeywell International Inc.
02010 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
'SO 9oo1
This document is not intended to be used for installation purposes.
We try to keep our product information up -to -date and accurate.
We cannot cover all specific applications or anticipate all requirements.
ENCINEERINC 9 MANUFACTURING
QUALITY SYSTEMS
All specifications are subject to change without notice.
Made in the U.S. A.
For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118.
www.notifier.com
Page 2 of 2 — DN- 6937:C • 10/26/2010
D N- 60054: E
Intelligent Bases N
1350111 (A), B2OOS(A), B2O0SR(A) J N QT I F I E R
B21OLP(A), B2241 BI(A), B224RB(A) by Honeywell
Mounting Kits, and Accessories
General
Intelligent FlashScan@ and CLIP mounting bases and kits pro-
vide a variety of ways to install NOTIFIER detectors in any
application. Intelligent detectors can be mounted in either
flanged or flangeless bases depending on junction box selec-
tion (see Junction Box Selection Guide). Across this product
line, detectors plug in easily to the base with SEMS screws,
and models employ various 12 to 24 AWG wire ranges.
Relay, isolator, and sounder bases can be used to meet
local code requirements. Relay bases provide one Form -C
contact relay for control of auxiliary functions such as door clo-
sure and elevator recall. Isolator bases allow loops to continue
to operate under fault conditions and automatically restore
when the fault is removed. Sounder bases are available in
temporal and non - temporal pattern versions depending on
whether the signal is to be used for evacuation purposes.
4r
Flangeless Mounting Base
B501 (A)
i
Flanged Mounting Base
B210LP(A)
Specifications
Diameter:
— B501: 4.1" (104 mm).
— B224BI, B224RB, B210LP: 6.1" (155 mm).
— B200S /SR: 6.875" (17.46 cm).
Wire gauge:
— B224BI, B224RB: 14 to 24 AWG.
— B210LP, 8501, B200S /SR: 12 to 24 AWG.
Temperature range:
— B224BI, B224RB, B200S /SR: 32 °F to 120 °F (0 °C to
49 °C).
— B210LP, B501: -4 °F to 150 °F ( -20 °C to 66 °C).
Humidity range: 10% to 93% RH, non - condensing.
System temperature and humidity ranges: This system
meets NFPA requirements for operation at 0 °C to 49 °C (32 °F
to 120 °F); and at a relative humidity (noncondensing) of 85%
at 30 °C (86 °F) per NFPA, and 93% t 2% at 32 °C t 2 °C
(89.6 °F t 1.1 °F) per ULC. However, the useful life of the sys-
tem's standby batteries and the electronic components may be
adversely affected by extreme temperature ranges and humid-
ity. Therefore, it is recommended that this system and all
peripherals be installed in an environment with a nominal room
temperature of 15 °C to 27°C (60 °F to 80 °F).
Electrical Ratings
FOR B200S /SR:
External supply voltage: 16 to 33 VDC (VFWR)
Standby current: 500 pA maximum.
Alarm current:
— B200S: 25 mA maximum at high - volume setting;
15 mA maximum at low- volume setting.
— B200SR: 35 mA maximum.
SLC operating voltage: 15 to 32 VDC.
SLC standby current: 300 pA.
"s
Sounder Base
B200S(A), B200SR(A)
�! e
Relay Base
B224RB(A)
Sound output: measured in a UL reverberant room at 10 feet,
24 Volts (continuous tone).
— B200S, high - volume: Greater than 85 dBA minimum.
— B200S, low- volume: Greater than 75 dBA minimum.
— B200SR: Greater than 85 dBA minimum.
FOR B224RB, B224BI:
Operating voltage: 15 to 32 VDC (powered by SLC).
Standby ratings: <500 pA maximum @ 24 VDC.
Set time (B224RB only): short delay 55 to 90 msec; long
delay 6 to 9 seconds.
Reset time (13224RB only): 20 msec maximum.
Relay characteristics (B224RB only): two -coil latching relay;
one Form -C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9
A @ 110 VDC, and 3.0 A @ 30 VDC.
Product Line Information
INTELLIGENT BASES
8501: Flangeless mounting base.
B501 A: Flangeless mounting base, ULC Listed.
B501 BP: Bulk pack of B501 (10).
B21OLP: Flanged mounting base.
B21OLPA: Flanged mounting base, ULC listed
B21 OLPBP: Bulk pack of B21 OLP (10).
B20OS: Intelligent addressable sounder base capable of pro-
ducing sound output in high or low volume with ANSI Temporal
3, ANSI Temporal 4, continuous tone, marching tone, and cus-
tom tone.
B200SA: Same as B200S with ULC - listing.
B200SR: Intelligent sounder base capable of producing sound
output with ANSI Temporal 3 or continuous tone.
B200SRA: Same as B200SR with ULC - listing
DN- 60054:E • 7/22/2011 — Page 1 of 2
B224RB: Relay base.
B224RBA: Relay base, ULC Listed.
B224BI: Isolator base.
6224BIA: Isolator base. ULC Listed.
MOUNTING KITS AND ACCESSORIES
SMB600: Surface mounting kit, flanged.
F110: Retrofit flange for converting high - profile bases to low -
profile.
F110BP: Bulk pack of F110 (10).
F210: Accessory flange ring for B210LP(A) base (new
design). 6 -inch diameter.
F210BP: Bulk pack of F210 (10).
RA10OZ: Remote LED annunciator.
RA10OZA: Remote LED annunciator, ULC Listed.
MO2- 04 -00: Detector test magnet.
MO2- 09 -00: Test magnet with telescoping handle.
XR2B: Detector removal tool for current heads (T55- 127 -010
included).
Junction Box Selection Guide
XR2: Detector Remove Tool for use with low profile detector
heads, and FSL -751.
XP -4: Extension pole for XR2 /B (5 to 15 ft/1.524 to 4.572 m).
T55- 127 -010: Detector removal head.
BCK -20OB: Black detector kit, package of 10 (for use with
photo and ion detectors).
WCK -20OB: White detector kit, package of 10 (for use with
photo and ion detectors).
Agency Listings and Approvals
The listings and approvals below apply to intelligent bases as
noted. In some cases, certain modules or applications may not
be listed by certain approval agencies, or listing may be in pro-
cess. Consult factory for latest listing status.
• UL Listed: S911
• ULC Listed: S911
• FM Approved
• MEA: 22 -95 -E, 205 -94 -E Vol. 2; 257 -06 -E
• CSFM: 7300 - 1653:0126, 7135 - 1653:0213, 7300 - 0028:0173,
7300 - 1653:0109
Base Models
Single
Gang
3.5" Oct.
4.0" Oct.
4.0" Sq.
4.0" Sq.
with 3.0"
mud ring
50 mm
60 mm
70 mm
75 mm
B200S,B200SR
Yes
Yes
Yes
Yes
Yes
No
No
No
No
B501
No
Yes
No
No
Yes
Yes
Yes
Yes
No
B21OLP
Yes
Yes
Yes
Yes
Yes
No
No
No
No
B224RB
No
Yes
Yes
Yes
No
No
Yes
Yes
Yes
B224BI
No
Yes
Yes
Yes
No
No
No
Yes
Yes
NOTE: Box depth contingent on base and wire size.
Refer to National Electric Code or applicable local codes for appropriate recommendations.
FlashScan ®, NOTIFIER® and System Sensor(R) are registered trademarks
of Honeywell International Inc.
02011 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
1S0 9001 This document is not intended to be used for installation purposes.
We try to keep our product information up -to -date and accurate. KKNM
We cannot cover all specific applications or anticipate all requirements. MOM
ENCIMEEINC 6 MANIIINTIAINC All specifications are subject to change without notice.
QUALITY SYSTEMS Made in the U.S. A.
For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118.
www.notifier.com
Page 2 of 2 — DN- 60054:E • 7/22/2011
SpectrAlert® Advance
Indoor Selectable Output Speaker Strobes and
Dual Voltage Evacuation Speakers
dn- 60327:a2
(�J NOTIFIER"
by Honeywell
General
The SpectrAlert Advance Series of speakers and speaker
strobes is designed to reduce ground faults. The plug -in design
allows the installer to pre -wire mounting plates and dress the
wires before plugging in the speakers. The plastic cover pre-
vents nicked wires by covering exposed speaker components.
This design also allows faster installations with instant feedback
to ensure that wiring is properly connected, rotary switches to
select voltage and power settings, and 11 field selectable can-
dela settings for wall and ceiling speaker strobes.
The low total harmonic distortion of the SP speaker offers high
fidelity sound output while the SPV speaker offers high volume
sound output for use in high ambient noise applications.
SpectrAlert Advance makes installation easy
• Attach a universal mounting plate to a 4" x 4" x 2 -1/8" back
box. Flush mount applications are achievable without the
need for an extension ring.
• Connect the notification appliance circuit or speaker wiring to
the PEMS terminals on the mounting plate.
• Attach the speaker or speaker strobe to the mounting plate
by inserting the product tabs into the mounting plate grooves.
Rotate the device into position to lock the product pins into
the mounting plate terminals. The device will temporarily hold
in place with a catch until it is secured with a captured mount-
ing screw.
Features
• Plug -in design
• Protective cover isolates speaker components, reduces
ground faults
• Electrical compatibility with existing SpectrAlert products
• Field selectable candela settings on wall and ceiling units:
— Standard: 15, 15/75, 30, 75, 95, 110, 115
— High: 135, 150, 177, 185
• Shorting spring on mounting plate tests continuity before
installation
• Rotary switch simplifies field selection of speaker voltage and
power settings
• Universal mounting plate for wall- and ceiling -mount units
• Compatible with System Sensor synchronization protocol
• SP speakers offer high fidelity sound output
• SPV speakers offer high volume sound output
• Automatic selection of 12 or 24 volt operation at 15 and 15/75
candela
• No extension ring required
• Ceiling and wall mount application
• Optional tamper resistant Torx head screw included
Specifications
PHYSICAL SPECIFICATIONS
Operating Temperature: 32 °F to 120 °F (0 °C to 49 °C)
Humidity Range: 10 to 93% non - condensing
Dimensions, Wall- Mount:
SIPS Speaker Strobe: 6.0 "L x 5.0 "W x 4.7 "D
(includes lens and speaker)
. W
SPSV Speaker Strobe: 6.0 "L x 5.0 "W x 4.9 "D
(includes lens and speaker)
SP Speaker: 6.0 "L x 5.0 "W x 2.8 "D
SPSV Speaker: 6.0 "L x 5.0 "W x 2.9 "D
Dimensions, Ceiling- Mount:
SIPS Speaker Strobe: 6.8 "Dia x 4.7 °D
(includes lens and speaker)
SPSV Speaker Strobe: 6.8 °Dia x 4.8 "D
(includes lens and speaker)
SP Speaker: 6.8 "Dia x 2.8 "D
SPSV Speaker: 6.8 "Dia x 2.9 "D
ELECTRICAUOPERATING SPECIFICATIONS
Nominal Voltage (speakers): 25 Volts or 70.7 Volts (nominal)
Maximum Supervisory Voltage (speakers): 50VDC
Strobe Flash Rate: 1 flash per second
Nominal Voltage (strobes): Regulated 12VDC /FWR or regu-
lated 24DC /FWR
Operating Voltage Range (includes fire alarm panels with
built -in sync): 8 to 17.5V (12V nominal) or 16 to 33V (24V
nominal)
Operating Voltage with MOIL Sync Module: 9 to 17.5V (12V
nominal) or 17 to 33V (24V nominal)
Frequency Range: 400 to 4000 Hz
Power: 1 /4, 1 /2, 1, 2 watts
Agency Listings and Approvals
In some cases, certain modules may not be listed by certain
approval agencies, or listing may be in progress. Consult fac-
tory for latest listing status.
• UUULC Listed: S4048
• MEA:10 -08 -E
• CSFM:7320- 1653:201
• FM Approved
dn- 60327:a2 • 5/28/10 — Page 1 of 2
UL Maximum Strobe Current Draw (mA RMS)
o
Volts
to
Vol
C
FWR
DC
FWR
3
128
66
71
M751
2
148
77
81
Standard
A
NA
94
96
Candela
A
NA
158
153
Range
95
NA
NA
181
176
110
NA
NA
202
195
115
NA
NA
210
205
High
135
NA
NA
228
207
Candela
150
NA
NA
246
220
Range
177
NA
NA
281
251
185
NA
NA
286
258
Sound Output
UL ever eran
Wall Mount SP Series
86
83
80
77
Wall Mount SPV Series
90
87
84
81
Ceiling Mount SPC Series
86
83
80
77
Ceiling Mount SPCV Series
90
87
84
81
Wall Mount SIPS Series
85
82
79
76
Wall Mount SPSV Series
89
86
83
80
Ceiling Mount SPSC Series
85
82
79
76
Ceiling Mount SPSCV Series
1 89
86
83
80
Architectural /Engineering
Specifications
GENERAL
SpectrAlert Advance speaker and speaker strobes shall mount to a
4' x 4" x 2 -1/8" backbox. A universal mounting plate shall be used for
mounting ceiling and wall products. The notification appliance circuit and
amplifier wiring shall terminate at the universal mounting plate. Also,
SpectrAlert Advance speaker strobes when used with the Sync Circuit.
Module accessory, shall be owered from a non -coded notification appli-
ance circuit output and shall operate on a nominal 12 or 24volts. When
used with the Sync.Circuit Module, 12 volt rated notification appliance cir-
cuit outputs shall operate between nine and 17.5 volts; 24 volt rated notifi-
cation appliance circuit outputs shall operate between 17 and 33 volts.
Indoor SpectrAlert Advance products shall operate between 32 °F and
120 °F from a regulated DC, or full -wave rectified, unfiltered power supply.
Speaker strobes shall have field - selectable candela settings including 15,
15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185.
SPEAKER
The speaker shall be a System Sensor SpectrAlert Advance model
dual - voltage transformer speaker capable of operating at 25.0 or
7 .7 nominal Vrms. It should be listed to UL/ULC 1480 and shall be
approved for fire protective service. The speaker shall have a frequency
rangqe of 400 to 4000Hz and shall have an operating temperature between
32 °F and 120 °F. Speaker shall have power taps and voltage that are
selected by rotary switches.
SPEAKER STROBE COMBINATION
The speaker strobe shall be a System Sensor SpectrAlert Advance model
listed to UL1480 and UUULC 1971 and be approved for fire
protective signaling systems. Speaker shall be capable of operatingg at
25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have aire-
quency range of 400 to 4000Hz. Speaker shall have power tops which are
selected by rotary switch. The strobe shall comply with the NFPA 72
requirements for visible sigqnaling appliances, flashing at 1Hz over the
strobe's entire operating vottage range. The strobe light shall consist of a
xenon flash tube and associated lens /reflector system.
SYNCHRONIZATION MODULE
The module shall be a System Sensor Sync Circuit model MDL listed to
UL/ULC 464 and shall be approved for fire protective service. The module
shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a
4- 11/16" x 4- 11/16" x 2 -1/8" backbox. The module shall also control two
Style Y (class B) circuits or one Style Z (class A) circuit. The module shall
synchronize multiple zones. Daisy chaining two or more synchronization
modules together will synchronize all the zones they control. The module
shall not operate on a coded power supply.
Ordering Information
NOTE: (W) indicates white coloring; (R), red.
NOTE: 'A "suffix indicates ULC- Listed model.
WALL MOUNT
SP(W)(R)(A): Speaker only.
SP(W)(R)V(A): Speaker only, high dB; white.
SPS(W)(R)(A) *: Speaker strobe, selectable candela (15, 15/75,
30, 75, 95, 110, 115).
SPS(W)(R)H(A) *: Speaker strobe, selectable candela, high cd
(135, 150, 177, 185).
SPS(W)(R)V(A) *: Speaker strobe, selectable candela, high dB.
CEILING MOUNT
SPC(W)(R)(A): Speaker only.
SPC(W)(R)V(A): Speaker only, high dB.
SPSC(W *)(R)(A): Speaker strobe, selectable candela (15, 15/
75, 30, 50, 75, 95, 110, 115)
SPSC(W *)(R)H(A): Speaker strobe, selectable candela, high
cd (135, 150, 177, 185)
SPSC(W *)(R)V(A): Speaker strobe, selectable candela, high
dB (15, 15/75, 30, 50, 75, 95, 110, 115).
SPSC(W *)(R)VH(A): Speaker strobe, selectable candela, high
d8, high cd (135, 150, 177, 185).
ACCESSORIES
RFP(A): Retrofit plate (5 pack), red.
RFPW(A): Retrofit plate (5 pack), white.
SPBBSC(A): Ceiling mount backbox skirt, red.
SPBBSCW(A): Ceiling mount backbox skirt, white.
SPBBS(A): Wall mount backbox skirt, red.
SPBBSW(A): Wall mount backbox skirt, white.
TR(A): Wall mount trim ring, red.
TRW(A): Wall mount trim ring, white.
TRC(A): Ceiling mount trim ring, red.
TRCW(A): Ceiling mount trim ring, white.
*NOTE: Add -P to model number for plain housing (no 'FIRE'
marking on the cover), e.g. SPSW -P
SpectrAlert@ is a registered trademark of Honeywell International Inc.
02010 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
1S0 �oo� This document is not intended to be used for installation purposes.
We try to keep our product information up -to -date and accurate.
We cannot cover all specific applications or anticipate all requirements.
ENCINEERINC IL MANUFACNRINC All specifications are subject to change without notice.
QUALITY SYSTEMS Made in the U.S. A.
For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118.
www.notifier.com
Page 2 of 2 - dn- 60327:a2 •5/28/10