Loading...
HomeMy WebLinkAboutA11-0048TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Job Address: 68 E MEADOW DR VAIL Location.....: VAIL VILLAGE INN PHASE 3 UNIT 301 Parcel No...: 210108254019 Project No OWNER ENCHANTED MESA EXEMPT C/O FREDERICK S. OTTO PO BOX 3149 VAIL CO 81658 APPLICANT COMMERCIAL SPECIALISTS PO BOX 3913 EAGLE CO 81631 License: 161 -S CONTRACTOR COMMERCIAL SPECIALISTS 21 MARMOT LANE UNIT B5 EAGLE CO 81631 License: C000003355 Desciption: INTERIOR REMODEL Valuation: $5,610.00 CORP 09/13/2011 OF WE 09/13/2011 OF WE 10/10/2011 Permit #: A 11 -0048 Status ...: ISSUED Applied..: 09/13/2011 Issued . .: 10/10/2011 Expires. .: 04/07/2012 Phone: (970) 328 -1951 Phone: 970 - 328 -1951 ************************************* * * * + * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * + * * * * * * ** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN AD VA_NF-E BY TELEPHONE AT 970- 479 -2252 FROM 5:00 AM - 5 PM. SIGNATURE OF WNER OR CONTRACTOR FOR HIMSELF AND OWNEF Electrical --------- > $0.00 Total Calculated Fees - -> $498.38 DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00 Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $498.38 Will Call --------- > $0.00 Payments ------------------ > $498.38 TOTAL FEES --> $498.38 BALANCE DUE--- - - - - -> $0.00 Approvals: Item: 05600 FIRE DEPARTMENT 09/21/2011 mvaughan Action: AP CONDITIONS OF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN AD VA_NF-E BY TELEPHONE AT 970- 479 -2252 FROM 5:00 AM - 5 PM. SIGNATURE OF WNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADO Statement Statement Number: R110001437 Amount: $498.38 10/10/201102:41 PM Payment Method: Check Init: SAB Notation: 11179 - COMM. SPECIALISTS OF WESTERN COL ----------------------------------------------------------------------------- Permit No: All -0048 Type: ALARM PERMIT Parcel No: 2101- 082 - 5401 -9 Site Address: 68 E MEADOW DR VAIL Location: VAIL VILLAGE INN PHASE 3 UNIT 301 Total Fees: $498.38 This Payment: $498.38 Total ALL Pmts: $498.38 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 FIRE ALARM PERMIT FEES 210.38 PF 00100003112300 PLAN CHECK FEES 288.00 of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 -2128, Fax: 970- 479 -2452 Web: www.vailgov.com lopment Re iv�e� ,Co rd n to , 0", 01W A A"" ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: 68 EAST MEADOW DRIVE 301 (Number) (Street) (Suite #) Building /Complex Name: VAIL VILLAGE INN PHASE III Contractor Information: Company: COMMERCIAL SPECIALISTS Company Address: 210 MARMOT LANE UNIT 135 City: EAGLE State: CO Zip: 81631 Contact Name: TIM WARD Contact Phone: 970.328.1951 E -Mail TIM @CSWCFIRE.COM Town of Vail Contractor Registration No.: S -161 Dl9i1a11y signed by Tim Ward ON ­Ti, Ward, — COMMERCIAL SPECIALISTS, —NICET Tim Ward IV 911594 TIM@CSIG1 COM, c =US X Date: 2017 09.09 1151:45 -06'00' Contractor Signature (required) Property Information Parcel #: 210108254019 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: FRANCO RESIDENCE Owner Name: FRANCO Complete Valuation for Fire Alarm Permit: Fire Alarm $: $5,610.00 Office Use: n Project #: Building Permit #: - ?)I Alarm Permit #: A / l � Lot #: Block # Subdivision: Detailed Description of Work: ADDING SEVEN (7) NEVI SMOKE DETECTORS AND FIVE (5) SPEAKERS TO THE EXISTING NFS -640 FIRE ALARM SYSTEM. (use additional sheet if necessary) Does a Fire Alarm Exist? Yes ( +) No( ) Does a Sprinkler System Exist? Yes ( +) No( ) Work Class: New ( ) Addition ( ) Remodel ( +) Repair ( ) Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family (+ ) Commercial ( +) Restaurant ( ) Other ( ) Date Received: F N�SEP LE a W TE 0 9 7011 TOWN OF VAIL 29- May -09 FAPT- 851(A) Acclimate@ PIusTM Multi- Sensor DN- 6937:C * NOTI FI E R" Low - Profile Intelligent Detector by Honeywell Intelligent/Addressable Devices General The Notifier FAPT- 851(A) Acclimate(g) PIusTm detector is an intelligent, addressable, multi- sensing, low- profile detector designed for use with Notifier Onyx and CLIP series Fire Alarm Control Panels. The Acclimate Plus detector uses a combination of photoelec- tric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the Accli- mate Plus detector has a microprocessor in the detector head that processes alarm data. As a result, the Acclimate Plus detector adjusts its sensitivity automatically, without operator intervention or control panel programming. Areas where the Acclimate Plus detector is especially useful include office complexes, schools, college campuses, manu- facturing and industrial facilities, and anywhere else the use of a particular area may change. The Acclimate Plus detector automatically adjusts its sensitivity to the environment. FlashScan (U.S. Patent 5,539,389) is a communication proto- col developed to greatly enhance the speed of communication between analog intelligent devices and compatible systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features • Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor- based, combination photo and thermal technology. • FlashScanO and CLIP system compatible (NFS -320, NFS - 640, NFS2 -640, NFS -3030 and NFS2 -3030) • Addressable - analog communication. • Sleek, low- profile design. • Two -wire SLC connection. • Direct -Dial entry of address: (1 — 159 on FlashScan sys- tems; 1 — 99 on CLIP systems). • Addresses can be viewed and changed without electronic programmers. • Dual bi -color LED design provides 360° viewing angle. • LEDs lock red when in alarm. In FlashScan, LEDs flash green in standby for normal condition. • Built -in tamper- resistant feature. • Constructed of off -white fire - resistant plastic, designed to commercial standards, and offers an attractive appearance. • SEMS screws for wiring of the separate base. • Several base options, including relay, isolator, and sounder. • Built -in functional test switch activated by external magnet. • Listed to UL 268. • Capable of heat -only alarm mode, enabled by a special command from the panel. Smoke alarms are ignored. • Low- temperature signal at 45 °F +/— 10 °F (7.22 °C +/- 5.54 °C). 6937Pno1.1P9i!I' FAPT- 851(A) in B71OLP base (base ordered separately) Specifications Sensitivity: auto - adjusting levels: 1 to 2 % /ft. and 2 to 4 % /ft. with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4 % /ft. with systems; fixed - sensitivity levels: 1, 2, and 4 % /ft. with classic CLIP systems; 0.5, 1, 2, 3, and 4 % /ft. with FlashScan systems. Size: 2.0" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in B501 base, 6.1" (15.5 cm) diameter installed in B710LP base. Shipping weight: 5.2 oz. (147 g). Operating temperature: 0 °C to 38 °C (32 °F to 100 °F). Operating altitude: up to 10,000 feet. UL- Listed velocity range: 0 — 4000 ft. /min. (12192 m /min.), suitable for installation in ducts. Relative humidity: 10% — 93% noncondensing. Thermal sensing rating: fixed - temperature setpoint 135 °F (57 °C). ELECTRICAL SPECIFICATIONS: Voltage range: 15 — 32 volts DC peak. Standby current (max. avg.): 300 pA. Loop resistance: 50 ohms maximum; varies according to control panel used. Refer to panel installation manuals. LED current (max.): 6.5 mA Q 24 VDC (''ON "). Installation The FAPT- 851(A) plug -in detector uses a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug -in and remove detec- tors without using a ladder. Suitable mounting base boxes include: 4.0" (10.16 cm) square box. 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box Single -gang box (except relay or isolator base). NOTE: The FAPT- 851(A) detector has the unique ability to adjust sensitivity according to the environment, based on heat and smoke levels. Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a self - contained heater. DN- 6937:C • 10/26/2010— Pagel of 2 Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S1115 • ULC Listed: S1115 • MEA Listed: 225 -02 -E • FM Approved • CSFM:7272- 0028:0206 • U.S. Coast Guard: 161.002/42/1 (NFS -640) • Lloyd's Register: 02/60007 (NFS -640) • Maryland State Fire Marshal: Permit # 2122 Ordering Information NOTE: "A" suffix indicates ULC Listed model. FAPT -851: Low - profile intelligent multi- sensor detector. Must be mounted to one of the bases listed below. FAPT -851 A: Same as FAPT -851 but with ULC Listing. INTELLIGENT BASES B501 (A): Flangeless mounting base. B200S(A): Intelligent sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces the B501 BH series bases in retrofit applications. B710LP: Flanged mounting base. (6.1 ", 15.5 cm diameter) B71OLPA: Flanged mounting base, ULC Listed. B224RB: Relay base Screw terminals: up to 14 AWG (2.0 mm Relay type: Form -C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm).. B224RBA: Relay base, ULC Listed. B224BI: Isolator base. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). Maximum: 25 devices between isolator bases. B224BIA: Isolator base, ULC Listed. ACCESSORIES: F110: Retrofit replacement flange for older high profile bases. Converts bases for use with FlashScan@ detectors. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S. single -gang electrical box. Supported by B710LP(A) and B501 (A) bases only. SMB600: Surface mounting kit for use with B710LP(A). BCK -20OB: Black detector covers, box of 10. MO2- 04 -00: Test magnet. MO2- 09 -00: Test magnet with telescope stick. XR2B: Detector removal tool. Allows installation and /or removal of FlashScan@ Series detector heads from base in high ceiling installations. T55- 127 -010: Detector removal tool without pole. XP -4: Extension pole for XR2B. Comes in three 5 -ft. sections. Notifier0, ONYX (5, FlashScanO, and Acclimate@ are registered trademarks and Acclimate Plus— is a trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 'SO 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEERINC 9 MANUFACTURING QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 2 of 2 — DN- 6937:C • 10/26/2010 D N- 60054: E Intelligent Bases N 1350111 (A), B2OOS(A), B2O0SR(A) J N QT I F I E R B21OLP(A), B2241 BI(A), B224RB(A) by Honeywell Mounting Kits, and Accessories General Intelligent FlashScan@ and CLIP mounting bases and kits pro- vide a variety of ways to install NOTIFIER detectors in any application. Intelligent detectors can be mounted in either flanged or flangeless bases depending on junction box selec- tion (see Junction Box Selection Guide). Across this product line, detectors plug in easily to the base with SEMS screws, and models employ various 12 to 24 AWG wire ranges. Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form -C contact relay for control of auxiliary functions such as door clo- sure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in temporal and non - temporal pattern versions depending on whether the signal is to be used for evacuation purposes. 4r Flangeless Mounting Base B501 (A) i Flanged Mounting Base B210LP(A) Specifications Diameter: — B501: 4.1" (104 mm). — B224BI, B224RB, B210LP: 6.1" (155 mm). — B200S /SR: 6.875" (17.46 cm). Wire gauge: — B224BI, B224RB: 14 to 24 AWG. — B210LP, 8501, B200S /SR: 12 to 24 AWG. Temperature range: — B224BI, B224RB, B200S /SR: 32 °F to 120 °F (0 °C to 49 °C). — B210LP, B501: -4 °F to 150 °F ( -20 °C to 66 °C). Humidity range: 10% to 93% RH, non - condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0 °C to 49 °C (32 °F to 120 °F); and at a relative humidity (noncondensing) of 85% at 30 °C (86 °F) per NFPA, and 93% t 2% at 32 °C t 2 °C (89.6 °F t 1.1 °F) per ULC. However, the useful life of the sys- tem's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15 °C to 27°C (60 °F to 80 °F). Electrical Ratings FOR B200S /SR: External supply voltage: 16 to 33 VDC (VFWR) Standby current: 500 pA maximum. Alarm current: — B200S: 25 mA maximum at high - volume setting; 15 mA maximum at low- volume setting. — B200SR: 35 mA maximum. SLC operating voltage: 15 to 32 VDC. SLC standby current: 300 pA. "s Sounder Base B200S(A), B200SR(A) �! e Relay Base B224RB(A) Sound output: measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone). — B200S, high - volume: Greater than 85 dBA minimum. — B200S, low- volume: Greater than 75 dBA minimum. — B200SR: Greater than 85 dBA minimum. FOR B224RB, B224BI: Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 pA maximum @ 24 VDC. Set time (B224RB only): short delay 55 to 90 msec; long delay 6 to 9 seconds. Reset time (13224RB only): 20 msec maximum. Relay characteristics (B224RB only): two -coil latching relay; one Form -C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0 A @ 30 VDC. Product Line Information INTELLIGENT BASES 8501: Flangeless mounting base. B501 A: Flangeless mounting base, ULC Listed. B501 BP: Bulk pack of B501 (10). B21OLP: Flanged mounting base. B21OLPA: Flanged mounting base, ULC listed B21 OLPBP: Bulk pack of B21 OLP (10). B20OS: Intelligent addressable sounder base capable of pro- ducing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and cus- tom tone. B200SA: Same as B200S with ULC - listing. B200SR: Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. B200SRA: Same as B200SR with ULC - listing DN- 60054:E • 7/22/2011 — Page 1 of 2 B224RB: Relay base. B224RBA: Relay base, ULC Listed. B224BI: Isolator base. 6224BIA: Isolator base. ULC Listed. MOUNTING KITS AND ACCESSORIES SMB600: Surface mounting kit, flanged. F110: Retrofit flange for converting high - profile bases to low - profile. F110BP: Bulk pack of F110 (10). F210: Accessory flange ring for B210LP(A) base (new design). 6 -inch diameter. F210BP: Bulk pack of F210 (10). RA10OZ: Remote LED annunciator. RA10OZA: Remote LED annunciator, ULC Listed. MO2- 04 -00: Detector test magnet. MO2- 09 -00: Test magnet with telescoping handle. XR2B: Detector removal tool for current heads (T55- 127 -010 included). Junction Box Selection Guide XR2: Detector Remove Tool for use with low profile detector heads, and FSL -751. XP -4: Extension pole for XR2 /B (5 to 15 ft/1.524 to 4.572 m). T55- 127 -010: Detector removal head. BCK -20OB: Black detector kit, package of 10 (for use with photo and ion detectors). WCK -20OB: White detector kit, package of 10 (for use with photo and ion detectors). Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S911 • ULC Listed: S911 • FM Approved • MEA: 22 -95 -E, 205 -94 -E Vol. 2; 257 -06 -E • CSFM: 7300 - 1653:0126, 7135 - 1653:0213, 7300 - 0028:0173, 7300 - 1653:0109 Base Models Single Gang 3.5" Oct. 4.0" Oct. 4.0" Sq. 4.0" Sq. with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B200S,B200SR Yes Yes Yes Yes Yes No No No No B501 No Yes No No Yes Yes Yes Yes No B21OLP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224BI No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. FlashScan ®, NOTIFIER® and System Sensor(R) are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. KKNM We cannot cover all specific applications or anticipate all requirements. MOM ENCIMEEINC 6 MANIIINTIAINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 2 of 2 — DN- 60054:E • 7/22/2011 SpectrAlert® Advance Indoor Selectable Output Speaker Strobes and Dual Voltage Evacuation Speakers dn- 60327:a2 (�J NOTIFIER" by Honeywell General The SpectrAlert Advance Series of speakers and speaker strobes is designed to reduce ground faults. The plug -in design allows the installer to pre -wire mounting plates and dress the wires before plugging in the speakers. The plastic cover pre- vents nicked wires by covering exposed speaker components. This design also allows faster installations with instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 11 field selectable can- dela settings for wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while the SPV speaker offers high volume sound output for use in high ambient noise applications. SpectrAlert Advance makes installation easy • Attach a universal mounting plate to a 4" x 4" x 2 -1/8" back box. Flush mount applications are achievable without the need for an extension ring. • Connect the notification appliance circuit or speaker wiring to the PEMS terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Rotate the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mount- ing screw. Features • Plug -in design • Protective cover isolates speaker components, reduces ground faults • Electrical compatibility with existing SpectrAlert products • Field selectable candela settings on wall and ceiling units: — Standard: 15, 15/75, 30, 75, 95, 110, 115 — High: 135, 150, 177, 185 • Shorting spring on mounting plate tests continuity before installation • Rotary switch simplifies field selection of speaker voltage and power settings • Universal mounting plate for wall- and ceiling -mount units • Compatible with System Sensor synchronization protocol • SP speakers offer high fidelity sound output • SPV speakers offer high volume sound output • Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela • No extension ring required • Ceiling and wall mount application • Optional tamper resistant Torx head screw included Specifications PHYSICAL SPECIFICATIONS Operating Temperature: 32 °F to 120 °F (0 °C to 49 °C) Humidity Range: 10 to 93% non - condensing Dimensions, Wall- Mount: SIPS Speaker Strobe: 6.0 "L x 5.0 "W x 4.7 "D (includes lens and speaker) . W SPSV Speaker Strobe: 6.0 "L x 5.0 "W x 4.9 "D (includes lens and speaker) SP Speaker: 6.0 "L x 5.0 "W x 2.8 "D SPSV Speaker: 6.0 "L x 5.0 "W x 2.9 "D Dimensions, Ceiling- Mount: SIPS Speaker Strobe: 6.8 "Dia x 4.7 °D (includes lens and speaker) SPSV Speaker Strobe: 6.8 °Dia x 4.8 "D (includes lens and speaker) SP Speaker: 6.8 "Dia x 2.8 "D SPSV Speaker: 6.8 "Dia x 2.9 "D ELECTRICAUOPERATING SPECIFICATIONS Nominal Voltage (speakers): 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers): 50VDC Strobe Flash Rate: 1 flash per second Nominal Voltage (strobes): Regulated 12VDC /FWR or regu- lated 24DC /FWR Operating Voltage Range (includes fire alarm panels with built -in sync): 8 to 17.5V (12V nominal) or 16 to 33V (24V nominal) Operating Voltage with MOIL Sync Module: 9 to 17.5V (12V nominal) or 17 to 33V (24V nominal) Frequency Range: 400 to 4000 Hz Power: 1 /4, 1 /2, 1, 2 watts Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in progress. Consult fac- tory for latest listing status. • UUULC Listed: S4048 • MEA:10 -08 -E • CSFM:7320- 1653:201 • FM Approved dn- 60327:a2 • 5/28/10 — Page 1 of 2 UL Maximum Strobe Current Draw (mA RMS) o Volts to Vol C FWR DC FWR 3 128 66 71 M751 2 148 77 81 Standard A NA 94 96 Candela A NA 158 153 Range 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL ever eran Wall Mount SP Series 86 83 80 77 Wall Mount SPV Series 90 87 84 81 Ceiling Mount SPC Series 86 83 80 77 Ceiling Mount SPCV Series 90 87 84 81 Wall Mount SIPS Series 85 82 79 76 Wall Mount SPSV Series 89 86 83 80 Ceiling Mount SPSC Series 85 82 79 76 Ceiling Mount SPSCV Series 1 89 86 83 80 Architectural /Engineering Specifications GENERAL SpectrAlert Advance speaker and speaker strobes shall mount to a 4' x 4" x 2 -1/8" backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes when used with the Sync Circuit. Module accessory, shall be owered from a non -coded notification appli- ance circuit output and shall operate on a nominal 12 or 24volts. When used with the Sync.Circuit Module, 12 volt rated notification appliance cir- cuit outputs shall operate between nine and 17.5 volts; 24 volt rated notifi- cation appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 °F and 120 °F from a regulated DC, or full -wave rectified, unfiltered power supply. Speaker strobes shall have field - selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. SPEAKER The speaker shall be a System Sensor SpectrAlert Advance model dual - voltage transformer speaker capable of operating at 25.0 or 7 .7 nominal Vrms. It should be listed to UL/ULC 1480 and shall be approved for fire protective service. The speaker shall have a frequency rangqe of 400 to 4000Hz and shall have an operating temperature between 32 °F and 120 °F. Speaker shall have power taps and voltage that are selected by rotary switches. SPEAKER STROBE COMBINATION The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UUULC 1971 and be approved for fire protective signaling systems. Speaker shall be capable of operatingg at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have aire- quency range of 400 to 4000Hz. Speaker shall have power tops which are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible sigqnaling appliances, flashing at 1Hz over the strobe's entire operating vottage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync Circuit model MDL listed to UL/ULC 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 4- 11/16" x 4- 11/16" x 2 -1/8" backbox. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Ordering Information NOTE: (W) indicates white coloring; (R), red. NOTE: 'A "suffix indicates ULC- Listed model. WALL MOUNT SP(W)(R)(A): Speaker only. SP(W)(R)V(A): Speaker only, high dB; white. SPS(W)(R)(A) *: Speaker strobe, selectable candela (15, 15/75, 30, 75, 95, 110, 115). SPS(W)(R)H(A) *: Speaker strobe, selectable candela, high cd (135, 150, 177, 185). SPS(W)(R)V(A) *: Speaker strobe, selectable candela, high dB. CEILING MOUNT SPC(W)(R)(A): Speaker only. SPC(W)(R)V(A): Speaker only, high dB. SPSC(W *)(R)(A): Speaker strobe, selectable candela (15, 15/ 75, 30, 50, 75, 95, 110, 115) SPSC(W *)(R)H(A): Speaker strobe, selectable candela, high cd (135, 150, 177, 185) SPSC(W *)(R)V(A): Speaker strobe, selectable candela, high dB (15, 15/75, 30, 50, 75, 95, 110, 115). SPSC(W *)(R)VH(A): Speaker strobe, selectable candela, high d8, high cd (135, 150, 177, 185). ACCESSORIES RFP(A): Retrofit plate (5 pack), red. RFPW(A): Retrofit plate (5 pack), white. SPBBSC(A): Ceiling mount backbox skirt, red. SPBBSCW(A): Ceiling mount backbox skirt, white. SPBBS(A): Wall mount backbox skirt, red. SPBBSW(A): Wall mount backbox skirt, white. TR(A): Wall mount trim ring, red. TRW(A): Wall mount trim ring, white. TRC(A): Ceiling mount trim ring, red. TRCW(A): Ceiling mount trim ring, white. *NOTE: Add -P to model number for plain housing (no 'FIRE' marking on the cover), e.g. SPSW -P SpectrAlert@ is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1S0 �oo� This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEERINC IL MANUFACNRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 2 of 2 - dn- 60327:a2 •5/28/10