Loading...
HomeMy WebLinkAboutB11-0343NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES ,. �'li� DF 6'A.ti.` ` Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0343 Job Address: 595 VAIL VALLEY DR VAIL Location......: MANOR VAIL UNIT 460 Parcel No....: 210108122011 OWNER PHENMAN, S.A. DE C.V. 09/20/2011 VIENA NO. 4 PH COLONIA JAREZ DELEGACION MIGUEL HIDALGO MEXICO DF 06600 APPLICANT NEDBO CONSTRUCTION INC 09/20/2011 Phone: 970-845-1001 PO BOX 3419 VAIL CO 81658 License: C000003087 CONTRACTOR NEDBO CONSTRUCTION INC 09/20/2011 Phone: 970-845-1001 PO BOX 3419 VAIL CO 81658 License: C000003087 Description: REMODEL EXISTING KITCHEN LAYOUT. ADD/CAHNGE EXISTING PANTRY TO BEDROOM AND BATHROOM. Occupancy: R-2 Type Construction: Project #: Applied.....: Issued. . . : P RJ 11-0544 09/20/2011 09/27/2011 Valuation: $130,000.00 .........................................«......,.........................,...... FEE SUMMARY ................................,..,...,........,,,............_............... Building Permit -----------> $1,161.75 Bldg Plan Check ----------> $755.14 Use Tax Fee-----------------------> $2,400.00 Electrical Permit ---------> $391.00 Elec Plan Check -----------> $254.15 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $120.00 Mech Plan Check ---------> $30.00 Additional Fees--------------------> $0.00 Plumbing Permit --------> $120.00 Plmb Plan Check ---------> $30.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 TOTAL PERMIT FEES-------------> $5,282.04 Payments------------------------------> $5,282.04 BALANCE DUE-----------------------> $0.00 firt++#htrlrxx/w V xt�f*xitxi�xktewRitet`t`4t(x*x***k'Rftr*Rt`**kk*Xwii#fwiR4t`trRilf*il11`trt(ff(i(f1`1trt4Ylkt�kffil'�RMY`MYrkYeff%'fFfF�kY`YlY(�R*fF�k*!'kY#YrYrffAYeRYtrffftY'#4Y'#f%�4i4f#Yr'R1ef�IrwR�RifR#�*****4t(1`1(4*rt%#*rt*YrYrYrM'iFY`YIfY`frtw�,FfY`iY DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:OOAM-4:00 / � � �_2�_% � Signature of Ow ntractor Date Print Name combination permit_012811 � � 1 VW� V� 1'l1tL ; .....,, ...............................................................................................x,..........,..............,.,.....,.,,,,,........,,...........,............,...... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: 611-0343 Owner: PHENMAN, S.A. DE C.V. MANOR VAIL UNIT 460 Address: 595 VAIL VALLEY DR VAIL Location: ......,, ...............,,....»,...,.......................,.......,...,,......,,...,,..,....,,,,............,..,.,..............................,......,,,............,...,.....,,..,,.. Cond: CON0012191 Changes to sprinkler system or fire alarm system shall take place under separate permitting. Smoke detectors shall be a minimum of three feet from return air vents. combination permit_012811 , # Ta�V�I f�F YA� ' ...*****�*****.,***********„�****„*******�.�******.,******�********..************,.,,.********�**************************,.**********„**w*,**.**.*,,,*** REQUIRED INSPECTIONS AND STATUSES Permit #: B11-0343 Owner: PHENMAN, S.A. DE C.V. MANOR VAIL UNIT 460 Address: 595 VAIL VALLEY DR VAIL Location: ******************„*„***��,.,.,..,,,«„*«**�**********««**«***************„**«„«*******„*««**«**********,.,,«***«********************«****«*««*************** Item Item Item Item Item Item Item Item Item Item 00120 ELEC-Rough 00200 MECH-Rough 00220 PLMB-Rough/D.W.V. 00230 PLMB-Rough/Water 00030 BLDG-Framing 00060 BLDG-Sheetrock Nail 00190 ELEC-Final 00290 PLMB-Final 00390 MECH-Final 00090 BLDG-Final combination permit_012811 **********************************�**++**************************************************+** TOWN OF VAIL, COLORADO Statement **************************************�*�*************************************************** Statement Number: R110001328 Amount: $4,599.70 09/27/201111:56 AM Payment Method: Check Init: SAB Notation: 40727 - NEDBO CONSTRUCTION ----------------------------------------------------------------------------- Permit No: B11-0343 Type: COMBINATION BLDG PERMIT Parcel No: 2101-081-2201-1 Site Address: 595 VAIL VALLEY DR VAIL Location: MANOR VAIL UNIT 460 Total Fees: $5,282.04 This Payment: $4,599.70 Total ALL Pmts: $5,282.04 Balance: $0.00 ****************************************************************�*************************+* ACCOUNT ITEM LIST: Account Code BP 00100003111100 EP 00100003111100 MP 00100003111100 PF 00100003112300 PP 00100003111100 UT 11000003106000 WC 00100003112800 Description BUILDING PERMIT FEES ELECTRICAL PERMIT FEES MECHANICAL PERMIT FEES PLAN CHECK FEES PLUMBING PERMIT FEES USE TAX 4% WILL CALL INSPECTION FEE Current Pmts 1,161.75 391.00 120.00 386.95 120.00 2,400.00 20.00 � � �� #���a L, � �,.: �,, . ;� � , .� �_ , ,,�; �:���! F� !�� �,�,�, ' Department of Community Development �. �� a�� 75 South Frontage Road '� ° `� � �'` � ' ;"` Vail Colorado 81657 ,�� . � ` �*� � Tel: 970-479-2128, .: � �, �� � ! � ° ,. �� � . w���' ' Web: www.vail ov.com �; `` ��,..:� � - ,,�.�` , 9 �,�":�_�. , Development Review Coordinator �,� �� �. �., .;� �;� . , i�''�*�:, a{ �. � . � `� � w-.� �� �w � -• BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: s��s U�� � �P�,�I�cY l�r. ���� (Number) (Street) (Suite #) Building/Complex Name: l�lG11G�' Vk�� Contractor Information Business Name: %'�Q��a Ct;�s��u�j�n yt riC Business Address: i�v %�jac 3 iii�j City �N� � State: l� Zip: fS��O S� Contact Name: l�lli�� �j�sln? Contact Phone: _ C1 %% OZ(o� Contact E-Mail: ►^U�%ie � !ud , ��� Contractor.fiegistration Numb : /�} / x �"�� ,�%'1/ ` Owner/Owner's Represe ative Signature (Required) Project #: rjC,J / I — (7 S�/ �/ DRB #: �(//�} - Building Permit #: — ` Lot #: _ Block # Subdivision: Work Class: New ( ) Addition ( ) Alteration (j�) Type of Building: Single-Family ( ) Duplex ( ) Multi-Family ( ) Commercial � Other ( ) Work Type: Interior () Exterior () Both (',�j Electrical Mechanical Plumbing Project Informatiot� Building Owner Name: ]-'h.�Yrl'►Y,�y� . 5, A �� [ �f Parcel#:_ Zlb� -pg� - Z _Djj (For Parcel #, contact Eagle County Assessors Office at (970328-8640 or visit www. ea g lecou nty. u s/patie) Detailed Scope and Location of Work: Valuation of Work Included Plans Included Work ( )Yes ( )No ( )Yes ( )No j� D ��(j ( )Yes ( )No ( )Yes ( )No iv�(�vL� ( )Yes ( )No ( )Yes ( )No 0 � U � U ( )Yes ( )No ( )Yes ( )No _ �L���OC��j Value of all work being performed: $ I��� (value based on IBC Section 709.3 & IRC Section 108.3� Electrical Square Footage � �% /7 k +ni/ � i � t�ictlldrl/ �r� IS.�+r r�m �nr.l ,6h'f4rCC7Yt I � (use additional sheet if necessary) For Office Use Only: Fee Paid: � (o$a 3y Received From: �d��iF �Ep�,> Cash Check # 4 Dlo 9 9 CC: Visa / MC Last 4 CC # exp date: Auth # Date Received: � C�1� ; , Vi ,� � �L.� L� � i_i �� � � ��� i � �.o.: TOWN OF VAIL O l-Jan-I 1 State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testina reauired� ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two-Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single-family dwelling: any dwelling unit that is used primarily for a single family, including multi-family/condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified abatement contractor. The clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: � Will not disturb more than the threshold limits identified above. � Tested negative, or at 1% or below (1 copies of test results included) � Tested positive at more than 1%, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos-containing materials, so buildings of � age require testing. • The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fi re_i nspectors@va i Igov. co m 970-479-2252 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303-692-3158 asbestos@state.co. us www.cdphe state co us O1-1an-11 � ■ ons� �n Asbestos Inspection and Sampling Report Manor Vail Lodge - Unit 460 585 Vail Valley Dr, Vail, Colorado 81657 Presented To: Mr. Mark Stevenson Nedbo Construction PO Box 3419 Vail, CO 81658 Performed & Prepared By: Mr. Steve Shurtliff DS Consulting, Inc. PO Box 6864 Avon,CO 81620 (303) 378-1544 Project Details: Project Number: 4641 Conducted: August 31, 2011 EXECUTIVE SUMMARY On August 31, 2011, Mr. Steve Shurtliff with DS Consulting, Inc. (DSC) performed a limited asbestos inspection and performed asbestos bulk-sampling within Unit 460 of the Manor Vail Lodge located at 585 Vail Valley Dr, Vail, Colorado, in order to identify potentially hazardous friable and non-friable asbestos- containing materials (ACM) within a portion of the above-referenced, single-family in which renovation activities are schedule, which include removing a few walls and drilling access holes for speakers throughout the unit. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material (ACM) as a material containing more than 1% asbestos. Mr. Shurtliff collected a total of three (3) asbestos bulk-samples from the following locations within the residence: Drywall Wall Texture • Main Level Closet Wall • Main Level Laundry Room Wall • Loft Ceiling All three (3) bulk-samples were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) accredited lab in Denver, Colorado. All three (3) bulk-samples reported as none-detect for asbestos -(see Appendix B for laboratory report). 2 PROJECT OVERVIEW I. Introduction A limited asbestos inspection and bulk-sampling for ACM was conducted at 585 Vail Valley Dr, Unit 460, Vail, Colorado, by Mr. Shurtliff on August 31, 2011 at the request of Mr. Mark Stevenson with Nedbo Construction. Mr. Shurtliff is a Colorado State Certified Building Inspector; having EPA Accreditation #15413 (see Appendix A for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non-friable ACM within portions of the residence that may be impacted by renovation activities. II. Structural Design The structure is a wood-framed, two-level, single-family residence within the Manor Vail Lodge. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a limited number of bulk-samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk-samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk-samples was performed on the "date reported," as listed in the bulk-sample analysis report. IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: Surfacing Material: sprayed or troweled onto structural building member. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one- tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response-action recommendations for asbestos-containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1% within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1% within the bulk-sample, or all bulk-samples in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a"TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1% unless it is analyzed by the point-count method to be less than 1%. V. Inspector Comments No asbestos-containing material was identified during the bulk-sampling conducted at 585 Vail Valley Dr, Unit 460, Vail, Colorado. A total of three (3) bulk-samples of drywall texture were collected from the above-referenced residence. All three (3) bulk-samples reported as none-detect for asbestos. 4 VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent-asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at 585 Vail Valley Dr, Unit 460, Vail, Colorado, on August 31, 2011. ND=None-detect. *The quantities of materials listed in this report are general approximations used specifically to determine the number of bulk-samples of each material to be collected. These quantities should not be used for any other purpose. On-site verification of the exact quantity of material is required for bidding purposes. � ��. .� ' 1 ���. .� � � Sample #: DW1-1 Sample #: DW1-2 Sample Description: Drywall Texture Sample Description: Drywall Texture Sample Location: Main Level Closet Wall Sample Location: Main Level Laundry Room Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: 200ftz Material Quantity: 200ftz Material Condition: Good Material Condition: Good Layers - Asbestos Content: Layers - Asbestos Content: White tape - ND White texture w/white paint - ND White joint compound - ND Tan/white drywall - ND White texture w/white paint - ND Tan white d wall - ND Recommendations: GENERAL - See Section VII Recommendations: GEIVERAL - See Section VII � ��. .� , � Sample #: DW1-3 Sample Description: Drywall Texture Sample Location: Loft Ceiling Material Classification: Surfacing Material Material Quantity: 200ftz Material Condition: Good Layers - Asbestos Content: White com ound w tan aint - ND Recommendations: GENERAL - See Section VII VII. Recommendations GENERAL: The laboratory results of the potential ACM sampled at 585 Vail Valley Dr, Unit 460, Vail, Colorado, indicate the bulk-samples of drywall texture collected from the residence reported as none- detect for asbestos. No professional abatement activities are recommended to remove the above- referenced material. 5 DISCLAIMER AND LIMITATIONS DSC performed the activities included in this report in a manner consistent with the level of care and expertise exercised by members of the environmental consulting profession. DSC performed all activities in accordance with all applicable federal, state, and local regulations, generally accepted standards and professional practice. No warranty is either expressed or implied. DSC assumes no responsibility or liability for error in public information utilized, statements from sources other than DSC, or developments resulting from situations outside the scope of this project. This report and the details provided within outline the inspection activities on the date(s) indicated, the limited number of bulk-samples collected, and the laboratory results of those bulk-samples. The laboratory results contained in this report apply specifically to the materials in which bulk-samples were collected. The results do not include or apply to any other materials within the structure that were not sampled but may contain asbestos. Additional inspection and bulk-sampling activities would be required to determine if any other materials contain asbestos. The information contained in this report is intended as supplementary material and is NOT to be used as the scope of work for abatement activities. DSC can provide a full scope of work for abatement upon request. The results of any surfacing material indicated in this report also include any associated overspray with that material, e.g., under carpet, above suspended ceilings, etc. C� APPENDIX A - INSPECTOR CERTIFICATION STATE OF COLORADO :�sEir s�ros � C;ERT11� IC.<�7'ION�` � Culoradu L)�p;u�tnxn� uf Public tle:dth cmd F.m iromm�nt �� Air Pollution (bnu�ul Divuion ,..}l. ...�. '` .;_ y , , J; ��IIS ililllll'i (�7;1� %: � -'1 Steve Shurtliff `� ` M� F ' ('crtification \u: l ja l i � ' ��)x ,. has met the reyuiremen?s o1 �S-', -�0?. ('.R.S. and Au t)uality ('ontrol �p :''`i C:om�izission ltegulalion N��. A. Part B. <and in h�rcb�� certiticd hy thc ;�j state of C'olorado in thc ti>Ilu�� in� disciplinc: t w� ,' ' =' �i1 ���,- Building Inspector* ::; ; � i.ti��a: e�i,��oi�i y {� � '� �-� ' '� kxpireson G�I�2011 �� � i � � � � , � � `�• �` �� �� r J r �' �' i �i. ` � �� k : I}. A +vLu f � � , AuWonzoOaP(.UReorexnlaaw �,$j' - �i `` � I 7'ki.r /' rhJ onlr w�tih �h� v.. .. n of. . r rn� tArniu upyn �r� �.a� �nA � nunr y' � iy �]. ^�+ '. �� trrti�cu w nlhr0iaiplinr.pml�JeDmr. a 1�1-.` �; . ..:.- `�. i i�' " '�, �i�.�: ,.. �... : .. . J"cAl I �Ye'�y : \ ��$`�� 1".r�" g �'� �+ ±.sl° � �iF' � ~+L'p Ww ✓.1� t$ ,� VF . . .. �.. . , ... „ �+ , .... . .�'G'. APPENDIX B - LABORATORY REPORT �l A�aobioloc�y Laboaa�roay ASSOC:IATES, INCGORPORATE(� 1�A.ar �r� �,l�r�u/ Client Name DS Consulting Street address �366 Flatrock Ct City, State ZIP Morrison, CO 80465 Attn: Stcvc ShurtlitT Client Project Name: Manor Vail-460 Certificate of Analysis ��dQ��� NVLAP Lab Code 200860-0 Tesc Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Matenals. EPA-600/R-93/I 16, July 1993. 13949 W. Colfa�c Ave Suite 205 Lakewood, CO 80401 303232.3746 ewvw aerobioloov.net Date Collected: 08/31/11 Date Received: 09/Ol/11 Date Malyzed: 09/07/] 1 Date Reported: 09/08/11 ProjectlD: 11010294 Job ID: Homo- La er Non-Asbestos Non-Fibrous Matnx Sample Identification physical Description of Sample/Layer geneous y Asbestos Detected Asbestos Percentage Fiber Matenal Material Client Lab Sam le Number �y�� Percentage Percenta e Percenta e Com osition I 1010294-1A White Tapc N 5% ND 95 5 11010294-1 B White Joint Compound N 5% ND 100 C DWl-1 11010294-1C White Texture w/White Paint N 10°/a ND 100 C 11010294-1D Tan/WhiteDrywall N 80% ND 10 90 G 11010294-2A White Texture w/White Paint N 35% ND 100 C DWl-2 1 IO10294-2B Tan/White Drywall N 65% ND 10 90 G DW 1-3 11010294-3 White Compound w/Tan Paint N 100% ND 100 C A = Amos�[e AC = Actinoli[e � AN = Mthophyllite � � �% � �.{����/�-���� CHRY=Chrysotile t.��— CR = Croc�dolite TR = Tremolite Ric Wegrzyn Pau Knappe Trace=LessThan 1% Laboratory Malyst Asbestos L.aboratory Supervisor ND=None Detected Page 1 of 2 13949 W. Colfau Ave. Suite 205, lakewood CO 8040I, 303.2323746 � _ �uartz r = renne C = Carbonates B = Binder G = Gypsum D=Diatoms M = Mica T=Tar NTR = Non-Asbestiform TR NAC = Non-Asbes[iform AC AEfZOb10IOCjy LAbORATOR�/ ASSOCIATES, INCORPORATED 1/�rr.�x; C.bl�r� Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerobiology.net DS Consulting 5366 Flatrock Ct Monison, CO 80465 Steve Shurtliff Client Project Name: Manor Vail-460 a�dQ�a> NVLAP Lab Code 200860-0 Date Collected: 08/31/I 1 Date Received: 09/O1/i l Date Analyzed: 09/07/11 Date Reported: 09/08/11 Project ID: 11010294 Job ID: Ceneral Notes ND indicates no asbestos was detected; the method detection limit is 1%. ♦ Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than 1%. ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current tenns and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples. ♦ Aerobiology does not guarantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to particle size, media used, and/or amount of material given. Analysis of these materials should be preformed by a TEM. A resu[t of ND does not indicate thallhe sample area daes not contain asbestos. !t means the analyst cou[d not identify asbestos in the specific samp[e for the reasons listed abov� Notes Required bv NVLAP ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless i[ bears the name of a NVLAP-approved signatory. ♦ Any reproduction of this document mus[ include the entire document in order for the report to be valid. Page 2 of 2 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 •�? - �� �� 12-15-2011 Inspection Request Reporting Page 6 4:46 pm Vail, C� - CitTpf Requested Inspect Date Site Address A/P/D Information Activity: 611-0343 Type: COMBO Const Type: Occupancy: Owner: PHENMAN, S.A. DE C.V. Contractor: NEDBO CONSTRUCTION INC Description: REMODEL EXISTING KITCHEN LAYOUT. BATHROOM. Requested Inspection(s) Item: 90 BLDG-Final Requestor: Comments: 977- 326 Assigned To: J GON Action: Time Exp: Item: 290 PLMB-Final Requestor: Comments: 977-0326 Assigned To: J O ON Action: Item: 390 MECH-Final Requestor: Comments: 977-0326 Assigned To: J AGON Action: �' Time Exp: Time Exp: Friday, December 16, 2011 595 VAIL VALLEY DR VAIL MANOR VAIL UNIT 460 Sub Type: AMF Status: ISSUED Use: R-2 Insp Area: Phone: 970-845-1001 ADD/CAHNGE EXISTING PANTRY TO BEDROOM AND Requested Time: 10:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 10:00 AM Phone: Entered By: MHAEBERLE K Requested Time: 09:30 AM Phone: < G �/ Inspection Historv � Item: 120 ELEC-Rough '* Approved *" �'�� 11/04/1 i Inspector: MD Action: AP APPROVED Comment: Item: 200 MECH-Rough 11/10/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: provide specs for dyer vent or booster see can see at final Item: 220 PLMB-Rough/D.W.V. Item: 230 PLMB-Rough/Water Item: 30 BLDG-Framing Item: 60 BLDG-Sheetrock Nail Item: 190 ELEC-Final *' Approved `* 12/14/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 290 PLMB-Final Item: 390 MECH-Final Item: 90 BLDG-Final Entered By: MHAEBERLE K REPT131 Run Id: 13897