Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B11-0345
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES �. �aw�oe�� 4 Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0345 Job Address: 675 LIONSHEAD PL VAIL Location......: 35 UNITS TO BE LISTED Parcel No....: 210106326001 OWNER ARRABELLE AT VAIL SQUARE LLC 09/20/2011 IN CARE OF NAME VAIL RESORTS MANAGEMENT CO 390 INTERLOCKEN CRESCENT STE 1000 BROOMFILED CO 80021 APPLICANT ENCORE ELECTRIC INC. 09/20/2011 Phone: 303-934-1234 2107 WEST COLLEGE AVE ENGLEWOOD CO 80110 License: C000003184 CONTRACTOR ENCORE ELECTRIC INC. 09/20/2011 Phone: 303-934-1234 2107 WEST COLLEGE AVE ENGLEWOOD CO 80110 License: C000003184 Project #: Applied.....: Issued. . . : PRJ 11-0546 09/20/2011 10/11 /2011 Description: PROVIDE AND INSTALL TWO NEW CAN LIGHTS ON EXISTING SWITCH LEGS IN 35 UNITS, REPLACE SWITCHES WITH NEW OWNER SUPPLIED DEVICES Occupancy: Type Construction: Valuation: $20,000.00 .............................................«......,....+........................ FEE SUMMARY .........................._...,...............,,.,,............,,..,............ Building Permit -----------> $321.25 Bldg Plan Check ----------> $208.81 Use Tax Fee-----------------------> $200.00 Electrical Permit ---------> $690.00 Elec Plan Check -----------> $448.50 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $0.00 Mech Plan Check ---------> $0.00 Additional Fees--------------------> ($530.06) Plumbing Permit --------> $0.00 Plmb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $5.00 TOTAL PERMIT FEES-------------> $1,343.50 Payments-------------------------°---> $1,343.50 BALANCE DUE-----------------------> 50.00 ................,..............�..........�.............«.......,,,..�..�...�...x..�............_...................:....,....................��.x..............�......,........_.......... DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. � ����'% � �°�<< �� � ignature of Owner or Contractor Date l'�'-���� ✓'� -�� '`?� Print Name combination permit_012811 � .. � 1 V 11lM V� IliiL , f�k�rtwrt#Yf Y'Yra!}i(LkY`#1(R4##frRi!**'4f f rt4i( Rf �R#*teR1�#Y'#RR*rtM'h#*R*Y`Y'f it1`'k1��kYwRR*f f w***Y`YrYe***kY'f *+tfrki#*�kYrk*t�#�Mf Yr*tertl`rtY'Yf **M'kNtrR1`1`Y.Y`#frf *YeYeYf k*MkY`�Rit**�1'Y(irt`1`*�kYrfiiR1`#rtrtrtf 1�4#�kwf 4Y'�kYrtf w#�iFX*/�#'frkf RirkRt'!1�*YrR CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: 611-0345 Address: 675 LIONSHEAD PL VAIL Owner: ARRABELLE AT VAIL SQUARE LLC Location: 35 UNITS TO BE LISTED ....................................»..,................................,,...........,....,.......,.....,,......,..,..............,...,...».....,,......,...,..,..........,....,...�, combination permit_012811 i ..: � TaWN �F �A� . *.***..**************,x****.*****�**�**********,*,***�*************************************,.***..****************************************,**....***,***,.* REQUIRED INSPECTIONS AND STATUSES Permit #: 611-0345 Address: 675 LIONSHEAD PL VAIL Owner: ARRABELLE AT VAIL SQUARE LLC Location: 35 UNITS TO BE LISTED ***«*****„**«*«***«**�*****.****«*****.,**************«***.«*************«*�,�********«.,***«****„**«****.,,,*««***.,**************,.***«*******«,.********** Item: 00120 ELEC-Rough item: 00190 ELEC-Final combination permit_012811 ********************+***************************************�******************************* TOWN OF VAIL, COLORADO Statement *********+************************�*******++*****+****************************************** Statement Number: R110001445 Amount: $895.00 10/11/201111:23 AM Payment Method: Check Init: SAB Notation: 2303 - ENCORE ELECTRIC ----------------------------------------------------------------------------- Permit No: B11-0345 Type: COMBINATION BLDG PERMIT Parcel No: 2101-063-2600-1 Site Address: 675 LIONSHEAD PL VAIL Location: 35 UNITS TO BE LISTED Total Fees: $1,343.50 This Payment: $895.00 Total ALL Pmts: $1,343.50 Balance: $0.00 ******************�********+****+*********************************************************�* ACCOUNT ITEM LIST: Account Code -------------------- EP 00100003111100 UT 11000003106000 WC 00100003112800 Description ------------------------------ ELECTRICAL PERMIT FEES USE TAX 4% WILL CALL INSPECTION FEE Current Pmts 690.00 200.00 5.00 New Can Liqht � � i S241 MAGNETIC DOOR SWITGH ENTRY 2 �CONDUCTOR 3 S564 )UCTOR ROOM � � ANNUNCIATOR EXISTING 3 !CONDUCTOR S1 , S217R5RF2 SWITCH � z - � ENTRY LINE VOLTAGE PC502 RF �S TRANSCEIVER 3 �CONDUCTOR T1 IEC E528RF FAN COIL UNIT �� A THERMOSTAT LOW VOLTAGE CONTROL S3 S217D4RF2 CIRC � ��'� SWITCH C BED LEFT LINE VOLTAGE S2 S4 , S217R5RF1 S217D4RF2 CIRC SWITCH � —� �-S SWITCH D LIVING AREA BED RIGHT LINE LINE VOLTAGE VOLTAGE � S1 0 S2 S5 S217R5RF1 CIRC E�� SWITCH E PICTURE LINE VOLTAGE REAaNG �� S3 .. _ _ _� _.. _ ... _. �'v1 _ � ,,, - _; - _ - . � SEP 14 2011 CABLE LEGEND ue� �. v� — — — C�10. 24ANG min m, CA75 a CA78 pxixred _� n��� .r. (T.). 18–B cable mhYnun u� va� DEVICE LEGEND 5241 �� Naqietk Doar s��n (s�a�) T1 ""cau °gna Th"�'i°► (628R� e�+ca►i s2�i s� SX � s�t� r��,ner s� lNCON RF Communicatbn DESIGN NOTES: 1. INNCOM S217 series switches require 3 conductors to function: Phase, Neutral, and Ground. 2. Wattage ratings on S217s must not be exceeded. Ratings are 500 Watts for Standard Non—Dimming and 400 Watts for Dimming. 3. S563 and S564 are existing INNCOM equipment. 4. Switch M is a master switch and is an existing switch. Switch is not needed with INNCOM solution. 5. INNCOM devices require uniterrupted power for proper operation. 6. INNCON thermostat T2 is a slaved thermostat and does not directly control the FCU. READING �� � ; �3 �J'v' � i v � ; - �r r� i ��.,.�.� FlRFPIA(E S5 � .���� S � �����E � E = d V a �o �"^ i�-= $,��� e � c� ZJ " #� g � s� � � � �� W � W W Q � � —� � W c� � � Q Q � � � � Q Q Arrabelle Resort INNCOM Cable Diagram Standard Unit SCALE: Not To Scale PROJECT � XlIX DRAWN BY: WSH DATES: 09 May 2011 s��r: 3 / � � � � � , '�� o� �,l� ` �� ___ � �� _ ______�_ � ... �� ; , i I � � � _�:�.. 4`� ---/ € � � � � I � i � [ � ' � �� � '� _ =� �I � CIRCUIT t - __ ; j k i � � sz�-3 � � CIRCUIT H - �: IiJ New Can Lipht G 0 CIRCUIT C 3a • • S4 aRCUir c aRCUir � CABLE LEGEND � �o. va�uge — — — C�le, 2M1MG minNnum, ��a��s� ___,o-- n�t� .r. (r.), 18-8 c�ls mhYnum ��� DEVICE LEGEND 5241 NNCbY 11ayi.tk Door Sdtch (5t41) Tl NNC011 Digftd Theimoatal ��� NNC011 5217 Saiee Sritdi ��. $X � Sritdi tManbs �sj NNCOAI RF Canmunication ' '� DESIGN NOTES: _. . ��� 1. INNCOM S217 series switches require 3 conductors to function: Phase, Neutral, and Ground. 2. Wattage ratings on S217s must not be exceeded. I Ratings are 500 Watts for Standard Non—Dimming , and 400 Watts for Dimming. CIRCUIT F 3. S563 and S564 are existing INNCOM equipment. 4. Switch M is a master switch and is an existing SEE switch. Switch is not needed with INNCOM solution. NOTE 6 5. INNCOM devices require uniterrupted power for \ proper operation. �� 6. INNCON thermostat T2 is a slaved thermostat and n_LS6 does not directly control the FCU. ��-. S� � ° � � � i --�'-` � �� CIRCUIT A _ � CIRCUIT J CIRCUIT K � � �41 � SEE S9 S10 NOTE 4 � � ��cTt`�t�� ; _ � ... CIRCUIT B �,1 _._ __�_ � '� � �UIT L �� CIRCUIT 0 ` M � CIRCUIT N , S13 S11 � � � � _, ;; S14 S1 , � �m� - • • i __ ! � � � � � � � G�RCIJIT M�� � � ��� � ___._ �� ._�_ _ � ._ _._. � _ .___ � �.,�� :i � �_ I �,';� _ New Can Light �,� SEP 14 2011 � ���� �� ���� � �w�, - � �� oW 3 O�� H� � ■���� ■e��ao Us �o �� � =LL� Z���� � �; ��� � N . °j � � � � �� W � � W Q _� � J � W c� m � Q Q � � � � Q Q REVISIONS DATE No DESCRIPTION Added two room 06May11 C types Added lighting D9Muy11 D fixtures to all room t es Updated lighting 09LIuy11 E in Staidard UnR Arrabelle Resort INNCOM Cable Diagram Room 228 SCALE: Not To Scale PRO�CT � XXX DRAWN BY: W�I DAlES: 09 May 2011 s��t a / � New Can Liaht �, � � ��m_m. _ w.� , � . _ _____ _ _ _ _ _ _ � �� � �-� �, . � � �; � � E[,y J ����- , [ �°,a��� ; ° , � � _ ��...� � - — - -- � i . � . � �, E r � ; . ...... __. ...._ __.J fI � e� ��� [l � .... �. • ��_, _ 5 3 r s^ _ • M'M � �s..� �-�� � CABLE LEGEND INIC011 Lo� Vdtaoe — — — �0. 24AVIC mininum, cn�s « c��a p.r.r.a �_ ,��� .� cT.>, 1&B code mhYnun Lirc Vdtage DEVICE LEGEND S241 INNCON Yaqietk Doa S�itch (5241) Ti H+ca� oqxd n,�,t� (a� r�ca►� s2�i s� SX � s.� Numnx er ? RNCON RF Communtcation DESIGN NOTES: 1. INNCOM S217 series switches require 3 conductors to function: Phase, Neutral, and Ground. 2. Wattage ratings on S217s must not be exceeded. Ratings are 500 Watts for Standard Non—Dimming and 400 Watts for Dimming. 3. S563 and S564 are existing INNCOM equipment. 4. Switch M is a master switch and is an existing switch. Switch is not needed with INNCOM solution. 5. INNCOM devices require uniterrupted power for proper operation. 6. INNCON thermostat T2 is a slaved thermostat and does not directly control the FCU. _.._..... __. _...��._,w... �,,„������I��(�`� � ''' 1 i' SEP 14 2011 ' Refaence Drawings � ����� ■����' F � V d � U���� Z LL c Z � � � qN� • `M Z �''g � � � � � O V / W � W �J � � � � � W cr� � � Q Q � � � � Q Q REVISIONS DATE No DESCRIPTION Added two room O6May11 C types Added lighting �a�11 D fixtures to all room t Updated I'�ghting 09Mny11 E in Stmdard Unit Arrabelle Resort INNCOM Cable Diagram ROOM 214 & 314 SCALE: Not To Scale PROJECT � XXX DRAWN BY: WSH DATES: 09 May 2011 SHEET: 6 / 7 ******r**�***********s�***************r*************�*******s**�*****s**�**r*r********�***** TOWN OF VAIL, COLORADO Statement *******�*****�*«*�***�********��******�*�*�************�******+��******��*******�*�**r*****� Statement Number: R110001255 Amount: $448.50 09/20/201109:42 AM Payment Method: Check Init: LC Notation: #2296 / encore electric inc ----------------------------------------------------------------------------- Permit No: B11-0345 Type: COMBINATION BLDG PERMIT Parcel No: 2101-063-2600-1 Site Address: 675 LIONSHEAD PL VAIL Location: 35 UNITS TO BE LISTED Total Fees: $1,343.50 This Payment: $448.50 Total ALL Pmts: $448.50 Balance: $895.00 **************************s*****�*******************�***�***�****�***s*****************��*** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 448.50 ----------------------------------------------------------------------------- rowN oF vai�i Project Street Address: 675 Lionshead Place Department of Community Development 75 South Frontage Road � 1 Vail, CO 81657 Tel: 970-479-2128 ( www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) (Number) (Street) (Suite #) Building/Complex Name: Arrabelle Contractor Information Business Name: Encore Electric Business Address: P.O. Box 8849 City Avon State: CO Zip: 81620 Contact Name: R. J. Vik Contact Phone: 970-471-0800 Contact E-Mail: rj.vik@encoreel c.com X ! Owner r's s tative Signature (Req ' ed) Applicant Information Applicant Name: Encore Electric (R. J. Vik) Applicant Phone: 970-949-9277 Project #: DRB #: �I� Building Permit #: 17 �` � (1 �� 7 Lot #: Block # Subdivision: Work Class: New ( ) Addition ( ) Alteration ( ✓ ) Type of Building: Single-Family ( ) Duplex ( ) Multi-Family ( ) Commercial (✓ ) Other ( ) Work Type: Interior (✓) Exterior () Both () Valuation of Work Included Plans Included Work Electrical ( ✓ )Yes ( )No ( ✓ )Yes ( )No �20,000 Mechanical ( )Yes ( )No ( )Yes ( )No Plumbing ( )Yes ( )No ( )Yes ( )No Building ( )Yes ( )No ( )Yes ( )No Applicant E-Mail: rj.vik@encoreelectric.com Value of all work being performed: $ 20,000 (value based on IBC Section 109.3 & IRC Section 108.3� Project Information Arrabelle at Vail Square Electrical Square Footage Owner Name: Parcel #: 2101-063-26-001 (For Parcel �, contact Eagle County Assessors Office at (970-328-8640 ar visit www.eaglecounty. us/patie) Detailed Scope and Location of Work: Provide and install two new can lights on existing switch legs in 35 units. Replace switches with new owner-supplied devices. (use additional sheet if necessary) For Office Use Only: Fee Paid: Received From: Cash Check # _ CC: Visa / MC Last 4 CC # Auth # exp date: Date Received: ,I��C�►��MC »��� i ; (K'�` SEP 1 �I 2011 � ; -� u i .. TC�WN OF VAIL 0 -Jan-11 OO Page 1 of 2 Calculite° Evolution Incandescent Open Downlight C4P20D 91/2" Dia. C4120 (Non-IC) 0 �� �3/4 12� ` �� 12 3/8" O.A. 91/4" � �• 1/2"� Ceiling C4PZODCLW / C4AIC Ceiling Cutout: 51/1G' (129 mm) Dia. Reflector Trim 9 1/2" Dia.— 0 ��4�� 13 3/4" t� � Adjustment 143/8' (mountingbars O.A. � / �l �ncluded) �/ 41/2" Aperture PAR20/PAR16/BR19/R20 Reflector Trim C4A120 � C4AIC (Non-IC AirSeal�) 10' 141/4" (IC AirSeal�� 7 3/4" min." � 81/4" max. I * 7 3/4" min. is for up to 3/4" thick ceiling C4P20D CLW Specular Clear, White Flange C4P20D CLP Specular Clear, Palished Flange C4P20D Q Add suffix. See optians far ather finishes. / � �13 3/4" to 24" Adjustment \/ �l (mounting b: included) 41/2"Dia.� C4P20DCLW/C4120or 53/4"Dia. C4P20DCLW/C4A120 Frame-In Kit Nan-IC Non-IC AirSeal� IC-AirSeal� C4120 C4A120 C4AIC 50W PAR20 50W PAR20 50W PAA20 75W PAA16 75W PAA16 75W PAA16 75W BR19, A20 75W BR19, R20 75W BR19, A20 Nan-IC Remadeler C4120RM 50W PAR20 75W PAR16 75W BR19, R20 Features 1. Reflector: 16 ga. Alzak� aluminum, 50° visual cutoff to lamp and lamp image. Available with painted white or polished flange. Interchangeable with other Evolution 41/2" line voltage trims. 2. Socket Harness: Spring tension clips snap into die-cast aluminum top at pre-focused positions ensuring correct optical alignment. Medium base porcelain socket with nickel plated screw shell, No. 18 SF-1 leads, and keyed plug-in quick cannector for pawer cannectian ta junction bax. 3. Frame-In-Kit: Compatible Frame-In Kits are listed above; see separate specification sheet for details. Non-IC and Non-IC AirSeal� - Insulation must be kept 3" away from flxture sides and wiring compartments and must nat be placed above fixture in a manner which will entrap heat. IC-AirSeal� - Fixture may be in direct cantact with insulation. Options and Accessories Retlector Finishes' Comiort Clear Diffuse CCD Specular Gold GD Specular Black BK White WH 'Specify desired flange W White, P Polished Labels UL Listed (suitable for damp locationsl, I.B.E.W. Alzak` is a registered trademark af ALCOA. US and Foreign Patents Pending. Job Name: Cat. No.: Lamp(s): Noter. Type: Lightolier a Genlyte Thamas Company www.lightalier.cam 631 Airport Road, Fall River, MA 02720 • 1508� 679-8131 • Fax (5081674-4710 We reserve the right to change details of design, materials and finish. OO 2003 Genlyte Thomas Group LLC (Lightolier Division� • B0403 � 1 � � �� � � �' � � � 1 � � 1'1 � � � Calculite° Evolution Incandescent Open Downlight PageZof2 Spacing Aatio = 0.6 CerOfied Test Fepart Na. OB38FA Compu[ed By lSl Program "Test-Li[e" Fecessed Open Aeflecmr pownlight 41/1' Dia. Aperture, Specular Clex Finish Reflecror SOW PAF7Q NFl Syivania Lamp. Luman FatinB = 530 LMS. Candlepower Summary Mgle Mean CP Lumens 0 14i3 5 1186 175 �0 1036 15 879 236 20 565 15 159 135 ao ea 35 I6 73 40 12 a5 3 4 50 0 55 0 0 60 0 ss a a �a a 75 a a BO 0 es a a sa o 2analLurtrena Md Percentages Zone Lumens %lamp %Luminaire 0-30 448 92.09 94]fi 0-a0 511 96.49 99.18 0-60 514 97.17 99.98 0-90 515 97.79 100.00 d0-W 3 JO J2 so-so a os a� �ate: July 19, 1999 9a-iea o .00 00 Preparedfor �-�80 st5 stts iaa.oa Lightalier, Fall River, MA �' E�tineMy=9z1% '• Tested According Ta IES Pmcedures. Test Distance Exceeds Five Tmes The Greatest luminous Opening Of Luminaire. Coefficients of Utilization % Effective Ceiling Cavity Reflectance 80 I 70 I 50 I 30 I 10 � 0 °k Wall Reflectance 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 1.11 1.09 1.08 1.09 1.07 1.06 .05 1.04 1. U3 .01 1.01 1.00 .98 .98 .97 .95 2 1.061.04 1.021.05 1.02 1.01 .021.00 .98 .99 .98 .96 .97 .96 .94 93 0 3 1.031.00 .971.01 .99 .97 .99 .97 .95 .97 .95 .94 .95 .94 .93 .91 � 4 1.00 .96 .94 .99 .96 .93 .97 .94 .92 .95 .93 .91 .93 .92 .90 .89 �' S .96 .93 .9� .95 .92 .90 .94 .91 .89 .92 .90 .88 .91 .89 .88 .87 � 6 94 .90 .88 .93 .90 .BB .92 .89 .87 .91 .88 .87 .90 .88 .86 .85 g 7 91 .88 .85 .91 .87 .85 .89 .87 .85 .88 .86 .84 .88 .85 .84 .83 � 8 .88 .85 .83 .88 .85 .82 .87 .84 .82 .86 .84 .82 .86 .83 .81 .81 9 .86 .83 .80 .86 .83 .80 .85 .82 .BO .84 .81 .80 .84 .81 .79 .79 10 .84 .81 .78 .84 .81 .78 .83 .80 .78 .82 .80 .78 .82 .79 .78 .77 Conversion Factors 20°h floor Caviry Reflectance 35W, SOW PAR20 NFI: Clear, C.U.x 1.0; Diffuse/Gold, C.U.x 0.95; Black, C.U.z 07 60W, 75W PAR16 NFL: Clear, C.U.x 0.90; Diffuse/Gold, C.U.x 0.85; Alack, C.U.x 0.6 C4P20D 41/2" Aperture PAR20/PAR16/BR19/R20 Reflector Trim Spacing Ratio =1.0 Certlfied Test Feport Na. 0839FP Computed By l51 Pmgram ^Test-Lite" flecessed Open fleflecmr Oownlight � 41/Z' Oia. Aperture, Specular Clear Finish Peflecmr � 75W Ai0 GE Lamp. Wmen Faong = fi50 LMS. CandlepowerSummary �'�� r Angle Mean CP Lumens �. � 0 479 5 479 4fi � ;-� 10 489 � 15 509 147 ' 70 500 � 75 447 199 1 �o a�s i � � .. 35 197 131 _ . 40 110 � 45 25 32 � 50 3 � 55 1 1 60 0 ���� fi5 0 0 I1�111 �o a '--' 75 0 0 ! Bp p r 85 0 0 � � C so a ,___. Zonal Lumens Md Percentages 2ane Lumens %Wmp %L�vninaire 0-30 387 59.60 70.3) 0-a0 518 79.69 94.09 0-60 55� 84.69 99.99 0-90 550 8470 100 00 a0-90 32 5.01 591 sa-s� a ai oi sa-ieo a o0 00 0480 50 B4J� t00.00 ° EtticiencY=64.7% •• Tested Accarding Ta IES Pmcedures. Test Oistance E�eeds Five Tmes The Greatest Luminous Opening Of Luminaire Date: July 19, 1999 Preparedfor Lightolier, Fail River, MA t 2 0 3 a 4 � 5 'a 6 � � °o B � 9 10 Coefficients of Utilization % Effective Ceiling Cavity Reflectance 80 70 50 30 10 0 % Wall Reflectance 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 95 .93 .92 .94 .92 .90 .90 .89 .88 .87 .86 .85 .84 .83 .83 .81 90 .87 .85 .88 .86 .84 .86 .84 .82 .83 .82 .80 .81 .80 .79 .77 85 .82 .79 .84 .81 .78 .82 .79 .77 .80 .78 .76 .78 .76 .75 .74 81 .77 .74 .80 .76 .73 .78 .75 .73 .76 .74 .72 .75 .73 .71 .70 76 .72 .69 .75 .71 .69 .74 .71 .68 .73 .70 .68 .71 .69 .67 .66 73 .68 .65 ..72 .68 .65 .71 .67 .64 .70 .6fi .64 .68 .66 .64 .63 68 .64 .61 ..68 .64 . fi 1 .67 .63 .61 .66 .63 . fi 0 . fi 5 . fi 2 .60 .59 65 .6U .57 .64 .60 .57 .63 .60 .57 .63 .59 .57 .62 .59 .56 .55 61 .57 .54 .61 .57 .54 .60 .56 .53 .59 .56 .53 .58 .55 .53 .52 58 .53 .50 .57 .53 .50 .57 .53 .50 .Sfi .52 .50 .56 .52 .50 .49 20°� Floor Cavity Reflectance Conversion Factors 30W to 75W R20: Clear, C.U.x 1.00; Diffuse/Gold, C.U.x 0.9; Black, C.Ux OA5 Type: Lightolier a Genlyte Thomas Company www.lightolier.com 631 Airport Aoad, Fall River, MA 02720 •(508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. OO 2003 Genlyte Thomas Group LLC ILightolier Division) • 80403 � N � � � f� � � '° �..�..� � � ^ J L.-__-� - 1 - � �� - � �I � � - ' - - 111 - � �I I- D3�15 PANEL LWH4A SECTION #1 PROJECT: ARRABELLE NEW HOTEL LIGHTS ENGINEER: SOH PROJECT #: 11081 VOLTAGE: 120/208V, 3P, 4W MOUNTING: SURFACE MAINS: 250A MCB TYPE: SEIMENS AIC: 10K PHASE PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION HEAT TRACE DECK DRAINS 1000 20 1 1 2 1 20 360 HOTEL #228 AIR CONDITIONING 1000 20 2 3 4 1 20 885 HOTEL #228 " 1000 5 6 1 20 1460 HOTEL #228 AC PUMP 500 20 1 7 8 1 20 1600 HOTEL #228 HOTEL #342 31 20 1 9 10 1 20 360 HOTEL #226 Hotel #344/334 31 20 1 11 12 1 20 885 HOTEL #226 HOTEL #352/336 31 20 1 13 14 1 20 1460 HOTEL #226 HOTEL #360/338 31 20 1 15 16 1 20 1600 HOTEL #226 HOTEL #362/340 31 20 1 17 18 1 20 360 HOTEL #334 HOTEL #359 31 20 1 19 20 1 20 885 HOTEL #334 HOTEL #361 31 20 1 21 22 1 20 1460 HOTEL #334 HOTEL #363 31 20 1 23 24 1 20 1600 HOTEL #334 HOTEL #352 360 20 1 25 26 1 20 360 HOTE� #336 HOTEL #352 885 20 1 27 28 1 20 885 HOTEL #336 HOTEL #352 1460 20 1 29 30 1 20 1460 HOTEL #336 HOTEL #352 1600 20 1 31 32 1 20 1600 HOTEL #336 HOTEL #358 360 20 1 33 34 1 20 360 HOTEL #338 HOTEL #358 885 20 1 35 36 1 20 885 HOTEL #338 HOTEL #358 1460 20 1 37 38 1 20 1460 HOTEL #338 HOTEL #358 1600 20 1 39 40 1 20 1600 HOTEL #338 HOTEL #360/338 360 20 1 41 42 1 20 360 HOTEL #340 LOAD CALCULATION SUMMARY NOTE: LOADS FROM SECTION #2 INCLUDED IN DEMAND LOAD CALCULATIONS CALCULATED POWER FACTOR: NEW LOADS ADDED TO CIRCUITS HIGHLIGHTED IN BOLD, 2 LIGHTS E ap�P ��sr��, 0.97 CIRCUIT ADDING 100 WATTS AT EACH CIRCUIT. „___ CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AN �=- --� '� '�� LIGHTING 28500 79 28500 79 • c 29840 �' RECEPTACLES 16920 47 13460 37 ~ ? �s��c, �� F�;�,'1 MECHANICAL 11554 38 12054 39 .�S {,��,aa��,:' KITCHEN 0 0 I� ��i- �,�� ;�, �i-��� i-�, ���, 0 0 � TOTAL 56974 163 ' � � � � !_ ' ' '�, _ %� _�� � 14 156 ;IDi _. ;� � , 9/28/2011 � TOWN OF VAIL PANEL LWH4A SECT 2 PROJECT: ARRABELLE NEW HOTEL LIGHTS ENGINEER: SOH PROJECT #: 11081 VOLTAGE: 120/208V, 3P, 4W MOUNTING: SURFACE MAINS: 250A MLO TYPE: SEIMENS AIC: 10K PHASE PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION HOTEL #360 885 20 1 43 44 1 20 885 HOTEL #340 HOTEL #360 1460 20 1 45 46 1 20 1460 HOTEL #340 HOTEL #360 1600 20 1 47 48 1 20 1600 HOTEL #340 HOTEL #362 360 20 1 49 50 1 20 360 HOTEL #342 HOTEL #362 885 20 1 51 52 1 20 885 HOTEL #342 HOTEL #362 1460 20 1 53 54 1 20 1460 HOTEL #342 HOTEL #362 1600 20 1 55 56 1 20 1600 HOTEL #342 HOTEL #363 360 20 1 57 58 1 20 360 HOTEL #344 HOTEL #363 885 20 1 59 60 1 20 885 HOTEL #344 HOTEL #363 1460 20 1 61 62 1 20 1460 HOTEL #344 HOTEL #363 1600 20 1 63 64 1 20 1600 HOTEL #344 HOTEL #361 360 20 1 65 66 1 20 360 HOTEL #359 HOTEL #361 885 20 1 67 68 1 20 885 HOTEL #359 HOTEL #361 1460 20 1 69 70 1 20 1460 HOTEL #359 HOTEL #361 1600 20 1 71 72 1 20 1600 HOTEL #359 HOTEL #226 0 20 1 73 74 1 20 100 CONTROL POWER DECK HT HOTEL #228 0 20 1 75 76 1 20 360 4 PLEX RECEPTACLE HEAT TRACE DECK DRAINS 1000 20 1 77 78 1 20 0 SPARE HEAT TRACE DECK DRAINS 1000 20 1 79 80 1 20 0 SPARE HEAT TRACE DECK DRAINS 1000 20 1 81 82 1 20 0 SPARE HEAT TRACE DECK DRAINS 1000 20 1 83 84 1 20 31 HOTEL #358 LOAD CALCULATION SUMMARY a �f�;'; CALCULATED POWER FACTOR: NEW LOADS ADDED TO CIRCUITS HIGHLIGHTED IN BOLD, 2 LIGHTS E oP '� ''`.•`' 0.97 CIRCUIT ADDING 100 WATTS AT EACH CIRCUIT. '�_-- —f r CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND Ati ' a 29840 s• LIGHTING 15200 42 15200 42 �s �� ,'' RECEPTACLES 16920 47 13460 37 �'s `� � MECHANICAL 6091 20 6341 21 S'�A`�'�� KITCHEN 0 0 0 0 TOTAL 38211 109 �� i i'; j'' i', \/ / 5001 100 ���,� � � � �,� � � ; _, �I ;'��� SEP 2 8 2011 I� 9/28/2011 � TOWN OF VAIL PANEL LWHSA SECTION #1 PROJECT: ARRABELLE NEW HOTEL LIGHTS ENGINEER: SOH PROJECT #: 11081 VOLTAGE: 120/208V, 3P, 4W MOUNTING: SURFACE MAINS: 250A MCB TYPE: SEIMENS AIC: 10K PHASE PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION HOTEL #208 360 20 1 1 2 1 20 360 HOTEL #206 HOTEL #208 885 20 1 3 4 1 20 885 HOTEL #206 HOTEL #208 1360 20 1 5 6 1 20 1360 HOTEL #206 HOTEL #208 1600 20 1 7 8 1 20 1600 HOTEL #206 HOTEL #208 360 20 1 9 10 1 20 360 HOTEL #206 HOTEL #212 360 20 1 11 12 1 20 360 HOTEL #210 HOTEL #212 885 20 1 13 14 1 20 885 HOTEL #210 HOTEL #212 1360 20 1 15 16 1 20 1360 HOTEL #210 HOTEL #212 1600 20 1 17 18 1 20 1600 HOTEL #210 HOTEL #212 360 20 1 19 20 1 20 360 HOTEL #210 HOTEL #216 360 20 1 21 22 1 20 360 HOTEL #214 HOTEL #216 885 20 1 23 24 1 20 885 HOTEL #214 HOTEL #216 1360 20 1 25 26 1 20 1360 HOTEL #214 HOTEL #216 1600 20 1 27 28 1 20 1600 HOTEL #214 HOTEL #216 360 20 1 29 30 1 20 360 HOTEL #214 HOTEL #220 360 20 1 31 32 1 20 360 HOTEL #214 HOTEL #220 885 20 1 33 34 1 20 885 HOTEL #218 HOTEL #220 1360 20 1 35 36 1 20 1360 HOTEL #218 HOTEL #220 1600 20 1 37 38 1 20 1600 HOTEL #218 HOTEL #220 360 20 1 39 40 1 20 360 HOTEL #218 SPARE 0 20 1 41 42 1 20 360 HOTEL #218 ��L LOAD CALCULATION SUMMARY NOTE: LOADS FROM SECTION #2 INCLUDED IN DEMAND LOAD CALCULATIONS �'^E��'';� ���a � �' � C A L C U L A T E D P O W E R F A C T O R: N E W L O A D S A D D E D T O C I R C U I T S H I G H L I G H T E D I N B O L D, 2 L I G H T S E A C H — �-- - 3=� 0.99 CIRCUIT ADDING 100 WATTS AT EACH CIRCUIT. a 2984� r ' ��s �,^`, CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AM � LIGHTING 25200 70 25200 70 '�ss,����,��,,•' RECEPTACLES 35640 99 22820 63 ��� MECHANICAL 3430 11 . — ---- 3470 11 KITCHEN 0 0 �'� �' � ��� �"�� �' ' � � ���� � � � � � 0 0 � �� I ��_: ��� � �_�__�� � I \ i �!_�_: TOTAL 64270 180 3; u� 51490 144 9i2si2o�� I TOWN OF VAIL '� PANEL LWH5A PROJECT: ARRABELLE NEW HOTEL LIGHTS ENGINEER: SOH PROJECT #: 11081 VOLTAGE: 120/208V, 3P, 4W MOUNTING: SURFACE MAINS: 250A MLO TYPE: SEIMENS AIC: 10K PHASE PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION HOTEL #224 360 20 1 43 44 1 20 360 HOTEL #222 HOTEL #224 885 20 1 45 46 1 20 885 HOTEL #222 HOTEL #224 1360 20 1 47 48 1 20 1360 HOTEL #222 HOTEL #224 1600 20 1 49 50 1 20 1600 HOTEL #222 HOTEL #224 360 20 1 51 52 1 20 360 HOTEL #222 HOTEL #322 360 20 1 53 54 1 20 360 HOTEL #320 HOTEL #322 885 20 1 55 56 1 20 885 HOTEL #320 HOTEL #322 1360 20 1 57 58 1 20 1360 HOTEL #320 HOTEL #322 1600 20 1 59 60 1 20 1600 HOTEL #320 HOTEL #322 360 20 1 61 62 1 20 360 HOTEL #320 HOTEL #326 360 20 1 63 64 1 20 360 HOTEL #324 HOTEL #326 885 20 1 65 66 1 20 885 HOTEL #324 HOTEL #326 1360 20 1 67 68 1 20 1360 HOTEL #324 HOTEL #326 1600 20 1 69 70 1 20 1600 HOTEL #324 HOTEL #326 360 20 1 71 72 1 20 360 HOTEL #324 SPARE 0 20 1 73 74 1 20 0 SPARE SPARE 0 20 1 75 76 1 20 0 SPARE SPARE 0 20 1 77 78 1 20 0 SPARE SPARE 0 20 1 79 80 1 20 0 SPARE SPARE 0 20 1 81 82 1 20 0 SPARE SPARE 0 20 1 83 84 1 20 0 SPARE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR: NEW LOADS ADDED TO CIRCUITS HIGHLIGHTED IN BOLD, 2 LIGHTS EACH CUt''p � rSr^ '; 0.99 CIRCUIT ADDING 100 WATTS AT EACH CIRCUIT. �-_ --- _ r __ � CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AI4 .'� a- 2984� T LIGHTING 10800 30 10800 30 v ?� �s `� : RECEPTACLES 15120 42 12560 35 FS �'�,;: MECHANICAL 1470 5 __ -- �� 1510 5 ���n;�,��''�` TOTAL�� 27390 7�7 ; � � �� � ����, � � �. � `' � �� � 0 0 . I I 24870 70 si2ai2o� � TOWN OF VAiL PANEL LWH5B ROJECT: ARRABELLE NEW HOTEL LIGHTS ROJECT #: 11081 OUNTING: SURFACE ENGINEER: VOLTAGE: MAINS: AIC: PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C HOTEL #306 360 20 1 1 2 1 20 360 HOTEL #306 885 20 1 3 4 1 20 885 HOTEL #306 1360 20 1 5 6 1 20 1360 HOTEL #306 1600 20 1 7 8 1 20 1600 HOTEL #312 360 20 1 9 10 1 20 360 HOTEL #312 360 20 1 11 12 1 20 360 HOTEL #312 885 20 1 13 14 1 20 885 HOTEL #312 1360 20 1 15 16 1 20 1360 HOTEL #312 1600 20 1 17 18 1 20 1600 HOTEL #312 360 20 1 19 20 1 20 360 HOTEL #316 360 20 1 21 22 1 20 360 HOTEL #316 885 20 1 23 24 1 20 885 HOTEL #316 1360 20 1 25 26 1 20 1360 HOTEL #316 1600 20 1 27 28 1 20 1600 HOTEL #316 360 20 1 29 30 1 20 360 SPARE 0 20 1 31 32 1 20 360 SPARE 0 20 1 33 34 1 20 360 SPARE 0 20 1 35 36 1 20 885 SPARE 0 20 1 37 38 1 20 1360 DECK SNOWMELT CONTRO 100 20 1 39 40 1 20 1600 SPARE 0 20 1 41 84 1 20 360 LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR: NEW LOADS ADDED TO CIRCUITS HIGHLIGHTED IN BOLD, 2 LIGHTS EACH 0.99 CIRCUIT ADDING 100 WATTS AT EACH CIRCUIT. CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND Ati LIGHTING 12600 35 12600 35 RECEPTACLES 18000 50 14000 39 MECHANICAL 1815 6�__..��.__,--v..__...___._______________ 1855 6 KITCHEN 0 0 i i 1 j�,� l,; i I i�1�� I i' �� f 0 0 TOTAL 32415 91 . ; �j � - ' ; i ' ;2g455 80 '� [J i� �." ... .. �� „ 9/28/2011 �_____TOWN OF VAIL SOH 120/208V, 3P, 4W 100A MLO 10K DESCRIPTION HOTEL #308 HOTEL #308 HOTEL #308 HOTEL #308 HOTEL #308 HOTEL #310 HOTEL #310 HOTEL #310 HOTEL #310 HOTEL #310 HOTEL #314 HOTEL #314 HOTEL #314 HOTEL #314 HOTEL #314 HOTEL #314 HOTEL #318 HOTE� #318 HOTEL #318 HOTEL #318 HOTEL #318 `a 29840 �' � T �� �� � �, � �r �S�i(�NA� 4�$_.J�J` � y `i 03-14-2012 Inspection Request Re orting Page 14 4:22 pm Vail, CO - Citv O� ��11- OS�f (l� Requested Inspect Date: Thursday March 15, 2012 Site Address: 675 LION�HEAD PL VAIL 35 UNITS TO BE LISTED A/P/D Information Activity: B11-0345 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type: Occupancy : Use: Insp Area: Owner: ARRABELLE AT VAIL SQUARE LLC Contractor: ENCORE ELECTRIC INC. Phone: 303-934-1234 Description: PROVIDE AND INSTALL TWO NEW CAN LIGHTS ON EXISTING SWITCH LEGS IN 35 UNITS, REPLACE SWITCHES WITH NEW OWNER SUPPLIED DEVICES Requested Inspection(s) Item: 190 ELEC-Final Requestor: ENCORE ELECTRIC INC. Comments: 401-1127 Assigned To: O D Action: > Time Exp: Item: 120 Item: 190 /� ��I � ugh ai Requested Time: 10:30 AM Phone: 303-934-1234 Entered By: JMONDRAGON K REPT131 Run Id: 14235