HomeMy WebLinkAboutB11-0351NOTE: TH/S PERM/T MUST BE POSTED ON JOBSITE AT ALL T/MES ,. ��o�u�i�� ° Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0351 Job Address: Location......: Parcel No....: 186 FOREST RD VAIL 210107115006 OWNER SNOW FOREST CHALET LLC 09/21/2011 GARFIELD& HECHT PO BOX 5450 AVON CO 81620 CONTRACTOR MAXIMUM COMFORT POOL & SPA I 09/21/2011 PO BOX 2670 VAIL CO 81658 License: C000003297 APPLICANT SNOW FOREST CHALET LLC 09/21/2011 GARFIELD& HECHT PO BOX 5450 AVON CO 81620 Phone: 970-949-6339 Description: RENOVATION OF EXISTING PATIO, ADDING OUTDOOR POOL, RENOVATION FO EXISTING SPA MECHANICAL AND SNOWMELT BOILERS. ADDING 46 SQUARE FEET ENCLOSING PARTIAL EXTERIOR DECK. REVISIONS TO SITE RETAINING WALL. Occupancy: R-3 Type Construction: VB Project #: Applied.....: Issued. . . : P RJ 11-0454 09/21 l2011 12/13/2011 Valuation: $585,569.00 ..,,,.....,,.,, ....................�.......,.....,.............,...,,,,.,.x........... FEE SUMMARY ._..................,,,........_.....�.,..,,..>,,........,,,,.,..................._ Building Permit -----------> $3,651.75 Bldg Plan Check ----------> $2,373.64 Use Tax Fee-----------------------> $11,511.38 Electrical Permit ---------> $920.00 Elec Plan Check -----------> $598.00 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $4,660.00 Mech Plan Check ---------> $1,165.00 Additional Fees--------------------> $0.00 Plumbing Permit --------> $120.00 Plmb Plan Check ---------> $30.00 Recreation Fee--------------------> $6.90 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 TOTAL PERMIT FEES--------------> $25,386.67 Payments-------------------------------> 525,386.67 BALANCE DUE------------------------> $0.00 _,....,. .................................._..».,,.....,..........,...,,.,.......__........,,...»...._.,..,,...,...................,........,..........,.........,...........,._.......,,. DECLARATIONS I hereby acknowledge that 1 have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. Signature of Owner or Contractor Print Name combination permit_012811 Date wxxw������xxwwww�xw..ww�������wxwwxr+xxrrwww���xwxww���xewwwwx����wwwwwwx��t��:www��x��x�wwwrxw���x��wwww�xx�x��www������x��wwr�x��xxxx+xwxw�wwxxxw�:xxwwwew�x��xxxx�x�t�xww+�+�x+r�� CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: 611-0351 Address: 186 FOREST RD VAIL Owner: SNOW FOREST CHALET LLC Location: ..................................................................................................................................................................................... Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 Cond: 44 (BLDG 2009): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R314 OF THE 2009 IRC, IF APPLICABLE UNLESS A MONITORED FIRE ALARM SYSTEM IS REQUIRED. combination permit_012811 � # 1 V�� V� Fi3ii/ i *,tw,+**,r***,ttx,r*,r**r*r*,t W ****,tr***,r*r,r***+e*w�**,r,r*r+**r******,tr*t,t**r*w,r*+t***r***x***��+rtnt***w,r,rrrr*terr*********,rxrt,t**tr**x,�x,+w,rr*r,rr,t**,trrwrr+,t**,+www*r* REQUIRED INSPECTIONS AND STATUSES Permit #: 611-0351 Address: 186 FOREST RD VAIL Owner: SNOW FOREST CHALET LLC Location: „*�***«««*****************,,,,**«****,.******�***�„«««�«**,.,�****«********«**�*�x**�*********,,,,««�********.,««******�«.,*****««***********«„*«*«**«.,******* Item: 00020 BLDG-Foundation/Steel 11/14/2011 By: JRM Action: AP Comments: PAD FOR VAULT ONLY Item: 00010 BLDG-FOOTING 12/05/2011 By: sgremmer Action: PI Comments: slab on grade Item: 00120 ELEC-Rough 12/05/2011 By: sgremmer Action: PI Comments: conduits under slab 06/29/2012 By: sgremmer Action: PI Comments: underground from meter to street will do street cut in September Item: 00110 ELEC-Service Item: 00130 ELEC-Conduit Item: 00220 PLMB-Rough/D.W.V. 11/23/2011 By: JRM Action: PA Comments: WATER LINE 100 # AIR TEST Item: 00200 MECH-Rough 11/04/2011 By: JRM Action: PI Comments: PARTIAL MECH ROUGH. VENTS THRU CHASE ONLY INSPECTED 11/23/2011 By: JRM Action: PA Comments: SNOW MELT MAINS 100 # AIR TEST 12/02/2011 By: JRM Action: PA Comments: SNOW MELT POOL DECK 100 # AIR TEST Item: 00240 PLMB-Gas Piping 11/23/2011 By: JRM Action: AP Comments: 3 LINES 20 # AIR TEST Item: 00250 PLMB-Pool/Hot Tub Item: 00410 Special Inspect-progress rept Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00420 Special Inspect-final rept Item: 00022 PLAN-ILC FRAMING Item: 00390 MECH-Final 06/13/2012 By: sgremmer Action: AP Item: 00290 PLMB-Final Item: 00542 PLAN-FINAL Item: 00190 ELEC-Final Item: 00090 BLDG-Final combination permit_012811 ***+****************+*******+*******************+******************+************************ TOWN OF VAIL, COLORADOCopy Reprinted on 02-19-2013 at 14:24:53 02/19/2013 Statement *******************************+*********************�***************«***********��***+***** Statement Number: R130000100 Amount: 5235.68 02/19/201302:24 PM Payment Method: Check Init: CG Notation: ck 50150 maximum comfort pool ----------------------------------------------------------------------------- Permit No: B11-0351 Type: COMBINATION BLDG PERMIT Parcel No: 2101-071-1500-6 Site Address: 186 FOREST RD VAIL Location: Total Fees: $25,386.67 This Payment: $235.68 Total ALL Pmts: $25,386.67 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 PF 00100003112300 Description Current Pmts ------------------------------ ------------ BUILDING PERMIT FEES 9.50 PLAN CHECK FEES 226.18 ----------------------------------------------------------------------------- 11 -25 -2013 Inspection Request Reporting 4:07 Dm Va>IJ,_(10_- _pity- fl __ -- Requested Inspect Date: Tuesday, ovember 26, 2013 Site Address: 186 FOREST RD VAIL Page 1 A /P /D Information Activity: 611 -0351 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occuppancy: Use: R -3 Insp Area: Owner: SNOW FOREST CHALET LLC Contractor: MAXIMUM COMFORT POOL & SPA INC Phone: 970 - 949 -6339 Description: RENOVATION OF EXISTING PATIO ADDING OUTDOOR POOL RENOVATION FO EXISTING SPA MECHANICAL AND SNOWMELT BdILERS. ADDING 46 SQUANE FEET ENCLOSING PARTIAL EXTERIOR DECK. REVISIONS TO SITE RETAINING WALL. - Reguested I t' nsoec on is, Item: 542 PLAN -FINAL Requested Time: 09:15 AM Requestor: Phone: Comments: 331 -1650 (f�G / 2 Assigned on: R J '! �I 7 Entered By: MHAEBERLE K Action: Time Exp: Z � w/ Cowl Item: 10 BLDG - FOOTING Requested Time: 09:00 AM Requestor: Phone: Comments: 331 -1650 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: Comment: slab on grade Item: 30 BLDG - Framing Requested Time: 10:00 AM Requestor: Phone: Comments: 331 -1650 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: Item: 50 BLDG - Insulation Requested Time: 11:00 AM Requestor: Phone: Comments: 331 -1650 Assigned To: MHAEBERLE Entered By: MHAEBERLE K Action: Time Exp: Item: 60 BLDG - Sheetrock Nail Requestor: Comments: 331 -1650 Assigned To: MHAEBERLE Action: Time Exp: Item: 90 BLDG -Final Requestor: Comments: 331 -1650 Assigned To: MHAEBERLE Action: Time Exp: Comment: ee pecia npsection Reprot Electrical Final Planning final Item: 250 PLMB -Pool /Hot Tub Requestor: Comments: 331 -1650 Assigned To: MHAEBERLE Action: Time Exp: REPT131 Requested Time: 11:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 12:00 PM Phone: Entered By: MHAEBERLE K Requested Time: 09:30 AM Phone: Entered By: MHAEBERLE K Run Id: 14655 e'3-?- - /0:3-0 11 -27 -2013 Inspection Request Reporting Page 1 4:05 pm Vail, CO - City Of Requested Inspect Date: Fridayy November 29 2013 Site Address: 186 FOREST RD VAIL A /P /D Information Activity: 1311 -0351 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occupancy: Use: R -3 Insp Area: Owner: SNOW FOREST CHALET LLC Contractor: MAXIMUM COMFORT POOL & SPA INC Phone: 970 - 949 -6339 Applicant: SNOW FOREST CHALET LLC Description: RENOVATION TTBLDR OUTDOOR OL RENOVATION TAL PA MECAN AND SNOW ME bIS ADDING SQUANE FEET ENCLOSING PARTIAL EXTERIOR DECK. REVISIONS TO SITE RETAINING WALL. Comment: RECEIVED THREE SETS OF REVISION PAGES (SHEET C1.2). ROUTED TO BIN D -1, PW AND RACHEL (DRB APP FOR THESE CHANGES SUBMITTED AT SAME TIME). - DRHOADES Comment: fire alarm and sprinkler system shall be modified for interior addition. - MVAUGHAN Comment: sent comments by email returned to C -3 - MHAEBERLE Comment: Transferred $250 000 to B11 -0412 er Martin. Separated out work into 2 permits. - DRHOADES Comment: RECEIVED RESOONSE TO CORRECTIONS. ROUTED TO BIN F -1 (BUNDLED WITH ORIGINAL SETS) AND BILL G. SCANNED TRANSMITTAL FORM AND ASSOCIATED PAPERWORK. - DRHOADES Comment: SCANNED APPLICATION. ROUTED TO BIN C-3, RACHEL AND FIRE. - DRHOADES Comment: Martin has for review - MHAEBERLE Comment: Building approved returned plans to F -1 awaiting PW and Planniong apppproval - MHAEBERLE Comment: RECEIVED 4 SETS OF REVISIONS SHOWING CHANGING THE MEC HANICAL VAULT FROM POURED CONCRETE TO BLOCK WALL. THICKENED SLAB FOOTING. ROUTED TO BIN A -2. - DRHOADES Comment: RECEIVED A LETTER FROM SOLGREEN ENGINEERING AND PROPERTY SOLUTIONS (VIAL MICHAEL CHARLES OF MAX. COMFORT STATING THAT A SPECIAL INSPECTION OF THE POOL IS NOT REQUIRED. STRUCTURAL EL�MENTS UNDER THE POOL WILL. SCANNED DOCUMENT AND ROUTED TO MARTIN FOR HIS APPROVAL. - DRHOADES Comment: Office set (not approved) moved to C -3. - RFRIEDE Comment: response to corrections routed to Rachel Dimond - BGIBSON Requested Inspections Item: 90 BLDG -Final Requested Time: 02:00 PM Requestor: MAXIMUM COMFORT POOL & SPA INC Phone: 970 - 949 -6339 Comments: 331 -1650 Assigned To: SGREMMER Entered By: JMONDRAGON K Action: Time Exp: Comment: ee pecia npsection Reprot Electrical Final Planning final Inspection History 1r1Ct� Item: 20 BLDG - Foundation /Steel ** Approved 11/14/11 Inspector: JRM Action: AP APPROVED Comment: PAD FOR VAULT ONLY Item: 10 BLDG - FOOTING 12/05/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: slab on grade Item: 120 ELEC -Rough ** Approved ** 12/05/1 i Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: conduits under slab 06/29/12 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: underground from meter to street will do street cut in September 11/05/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 110 ELEC - Service ** Approved ** 11/05/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 130 ELEC- Conduit '* Approved ** 11/05/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 220 PLMB - Rough /D.W.V. *' Approved ** 11/23/1T Inspector: JRM Action: PA PARTIAL APPROVAL Comment: WATERLINE 100 # AIR TEST Item: 200 MECH -Rough '* Approved ** 11/04/11 Inspector: JRM Action: PI PARTIAL INSPECTION Comment: PARTIAL MECH ROUGH. VENTS THRU CHASE ONLY INSPECTED 11/23/11 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: SHOW MELT MAINS 100 # AIR TEST 12/02/11 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: SNOW MELT POOL DECK 100 # AIR TEST REPT131 Run Id: 14778 TOWN OF VAIL' Department of Community Development 75 South Frontage Road Vail, CO 81657 1) 00 Tel: 970 -479 -2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM D"I"MI "PliE"O 6A A1' SAM Di"t Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: Attention: (q Revisions //yy 3 ( ) Response to Correction Letter /'g -%% - r �3,L n6 _attached copy of correction letter ()Deferred Submittal PL�L,�J�t)JtJG, rL) () Other P/`roject Street Address: dam, � (Number) (Street) (Suite #) Description / List of Changes: Building /Complex Name: Contractor Informa�tiionn Business Name: / ►�Ti� �OAj�d%L7S���,NF }� 1. I . Business Address: City State: Zip: Contact Name: //r ���F Gf1FJgit'L� (use additional sheet if necessary) Contact P E /)W, Gf►�!'l Revised ADDITIONAL Valuations (Labor & Materials) nta -M , (DO NOT include original valuation) Building: $ _ (C)fo, o Ow /Owner's Representative Signature (Required) Plumbing: $ Applicant Information / Electrical: $ Applicant Name: % u 67'L 6/E Mechanical: $ Applicant Phone: Total: $ A,�,, Applicant E- Mail: For Office Use Only: Fee Paid: Received From: Cash ' Check # _ CC: Visa / MC Last 4 CC # Auth # exp. date: Date Received: JAN 0 4 2012 TOWN OF VAIL 01- Oct -11 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0351 Job Address: 186 FOREST RD VAIL Location......: Parcel No....: 210107115006 OWNER SNOW FOREST CHALET LLC 09/21/2011 GARFIELD& HECHT PO BOX 5450 AVON CO 81620 CONTRACTOR MAXIMUM COMFORT POOL & SPA 109/21/2011 Phone: 970 - 949 -6339 PO BOX 2670 VAIL CO 81658 License: C000003297 APPLICANT SNOW FOREST CHALET LLC 09/21/2011 GARFIELD& HECHT PO BOX 5450 AVON CO 81620 Description: RENOVATION OF EXISTING PATIO, ADDING OUTDOOR POOL, RENOVATION FO EXISTING SPA MECHANICAL AND SNOWMELT BOILERS. ADDING 46 SQUARE FEET ENCLOSING PARTIAL EXTERIOR DECK. REVISIONS TO SITE RETAINING WALL. Project #: Applied.....: Issued... PRJ 11 -0454 09/21/2011 12/13/2011 Occupancy: R -3 Type Construction: VB Valuation: $585,569.00 .,,....« .......................«...,............. ..........,,,.......,.......... FEE SUMMARY ....,,..,........,............,................ ,...............,.............. Building Permit ------ - - - - -> $3,642.25 Bldg Plan Check ----- - - - - -> $2,367.46 Use Tax Fee------------------ - - - - -> $11,511.38 Electrical Permit ---- - - - - -> $920.00 Elec Plan Check ------ - - - - -> $598.00 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $4,660.00 Mech Plan Check ---- - - - - -> $1,165.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $120.00 Plmb Plan Check ---- - - - - -> $30.00 Recreation Fee--------------- - - - - -> $6.90 Investigation------------------ - - - - -> $0.00 Will Call- - - - - -- ---- -- - - -- -> $20.00 TOTAL PERMIT FEES --- ---------- > $25,150.99 Payments -- ---------------------------- > $25,150.99 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. Sign u're of O e r Contractor Date Pri rit Name combination permit_012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0351 Address: 186 FOREST RD VAIL Owner: SNOW FOREST CHALET LLC Location: Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 Cond: 44 (BLDG 2009): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R314 OF THE 2009 IRC, IF APPLICABLE UNLESS A MONITORED FIRE ALARM SYSTEM IS REQUIRED. combination permit_012811 TOWN OV�ATL REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0351 Address: 186 FOREST RD VAIL Owner: SNOW FOREST CHALET LLC Location: Item: 00020 BLDG - Foundation /Steel 11/14/2011 By: JRM Action: AP Comments: PAD FOR VAULT ONLY Item: 00010 BLDG - FOOTING 12/05/2011 By: sgremmer Action: PI Comments: slab on grade Item: 00120 ELEC -Rough 12/05/2011 By: sgremmer Action: PI Comments: conduits under slab Item: 00110 ELEC - Service Item: 00130 ELEC- Conduit Item: 00220 PLMB- Rough /D.W.V. 11/23/2011 By: JRM Action: PA Comments: WATER LINE 100 # AIR TEST Item: 00200 MECH -Rough 11/04/2011 By: JRM Action: PI Comments: PARTIAL MECH ROUGH. VENTS THRU CHASE ONLY INSPECTED 11/23/2011 By: JRM Action: PA Comments: SNOW MELT MAINS 100 # AIR TEST 12/02/2011 By: JRM Action: PA Comments: SNOW MELT POOL DECK 100 # AIR TEST Item: 00240 PLMB -Gas Piping 11/23/2011 By: JRM Action: AP Comments: 3 LINES 20 # AIR TEST Item: 00250 PLMB -Pool /Hot Tub Item: 00410 Special Inspect - progress rept Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00060 BLDG - Sheetrock Nail Item: 00420 Special Inspect -final rept Item: 00390 MECH -Final Item: 00290 PLMB -Final Item: 00190 ELEC -Final Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110001768 Amount: $110.00 12/13/201104:34 PM Payment Method:Credit Crd Init: LC Notation: CREDIT CARD FROM MICHAEL CHARLES, MAXIMUM COMFORT POOL /SPA ----------------------------------------------------------------------------- Permit No: Bll -0351 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 071 - 1500 -6 Site Address: 186 FOREST RD VAIL Location: Total Fees: $25,150.99 This Payment: $110.00 Total ALL Pmts: $25,150.99 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 110.00 TOWN OF VA nEnE[]V/En NOV 30 2011 IUI TOWN OF VAIL Department of Community Development 75 South Frontage Road hoz Vail, CO 81657 Tel: 970 -479 -2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Revision Submittals: 1. "Field Set' of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: 13- 11- D 3S / Attention: Project Street Address: (Number) (Street) (Suite #) Building /Complex Name: Contractor Information Business Name: M4�. e0",-V127- �et1L IF -S4eW Business Address: City KI L. State: Zip {::5'f,Revisions () Response to Correction Letter _attached copy of correction letter (__)Deferred Submittal ( ) Other Description / List of Changes: ii 2_ IN WAM rim, b + 1M1CK&_J4JED SLAA 5P iur, • Contact Name: M« C%MA&4L S To a5oo PST_ Contact Phone: �� �D Y - yo do Conta -t` -i1: Me 6L4f_L E7S % PF? NIC�S✓�IL. �d M X ( M Owner/6wnees Representative Signature (Required) (use additional sheet if necessary) Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: Plumbing: Applicant Information �ND � Electrical: Applicant Name: �$7 LLB Mechanical: Applicant Phone: Applicant E -Mail: For Office Use Only: Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # exp. date: Auth # Total: Date Received: $_ M $ E - 0t -Oct -> t n D Z Z M v NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES TOWN 0 VAtI, Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0351 Project #: PRJ11 -0454 Job Address: 186 FOREST RD VAIL Applied.....: 09/21/2011 Location......: Issued...: 10/21/2011 Parcel No....: 210107115006 OWNER SNOW FOREST CHALET LLC 09/21/2011 GARFIELD& HECHT PO BOX 5450 AVON CO 81620 CONTRACTOR MAXIMUM COMFORT POOL & SPA 109/21/2011 Phone: 970 - 949 -6339 PO BOX 2670 VAIL CO 81658 License: C000003297 APPLICANT SNOW FOREST CHALET LLC 09/21/2011 GARFIELD& HECHT PO BOX 5450 AVON CO 81620 Description: RENOVATION OF EXISTING PATIO, ADDING OUTDOOR POOL, RENOVATION FO EXISTING SPA MECHANICAL AND SNOWMELT BOILERS. ADDING 46 SQUARE FEET ENCLOSING PARTIAL EXTERIOR DECK. REVISIONS TO SITE RETAINING WALL. Occupancy: R -3 Type Construction: VB Valuation: $585,569.00 .................................................. ............................... FEE SUMMARY ..,...,.......................,.........._...... .,.,........................,,. Building Permit ------ - - - - -> $3,642.25 Bldg Plan Check ----- - - - - -> $2,367.46 Use Tax Fee------------------ - - - - -> $11,511.38 Electrical Permit ---- - - - - -> $920.00 Elec Plan Check ------ - - - - -> $598.00 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $4,660.00 Mech Plan Check ---- - - - - -> $1,165.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $120.00 Plmb Plan Check ---- - - - - -> $30.00 Recreation Fee--------------- - - - - -> $6.90 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $20.00 TOTAL PERMIT FEES--------- - - - - -> $25,040.99 Payments ------------------------------- > $25,040.99 BALANCE DUE ------------------------ > $0.00 DECLARATIONS hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECT BEN DE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00P to 2 t Zs Signature of Owner or Contractor Date Print Name combination permit_012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0351 Address: 186 FOREST RD VAIL Owner: SNOW FOREST CHALET LLC Location: Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 Cond: 44 (BLDG 2009): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R314 OF THE 2009 IRC, IF APPLICABLE UNLESS A MONITORED FIRE ALARM SYSTEM IS REQUIRED. combination permit_012811 OVAKUTOWN OF REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0351 Address: 186 FOREST RD VAIL Owner: SNOW FOREST CHALET LLC Location: Item: 00020 BLDG - Foundation /Steel Item: 00010 BLDG - FOOTING Item: 00120 ELEC -Rough Item: 00110 ELEC - Service Item: 00130 ELEC- Conduit Item: 00200 MECH -Rough Item: 00240 PLMB -Gas Piping Item: 00250 PLMB -Pool /Hot Tub Item: 00410 Special Inspect - progress rept Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00060 BLDG - Sheetrock Nail Item: 00420 Special Inspect -final rept Item: 00390 MECH -Final Item: 00290 PLMB -Final Item: 00190 ELEC -Final Item: 00090 BLDG -Final combination permit-012811 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADOCopy Reprinted on 10 -21 -2011 at 12:09:11 10/21/2011 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R110001530 Amount: $20,108.6510/21 /201112:09 PM Payment Method: Check Init: DR Notation: CK# 48376 MAX. COMFORT ----------------------------------------------------------------------------- Permit No: Bll -0351 Type: COMBINATION BLDG PERMIT Parcel No: 2101- 071 - 1500 -6 Site Address: 186 FOREST RD VAIL Location: Total Fees: $25,040.99 This Payment: $20,108.65 Total ALL Pmts: $25,040.99 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - BP 00100003111100 - -- ------------------------ - - - - -- ------ BUILDING PERMIT FEES - - - - -- 3,642.25 EP 00100003111100 ELECTRICAL PERMIT FEES 920.00 MP 00100003111100 MECHANICAL PERMIT FEES 4,660.00 PF 00100003112300 PLAN CHECK FEES - 771.88 PP 00100003111100 PLUMBING PERMIT FEES 120.00 RF 11100003112700 RECREATION FEES 6.90 UT 11000003106000 USE TAX 4% 11,511.38 WC 00100003112800 WILL CALL INSPECTION FEE 20.00 B11 -C -351 :a ®� SOLGREEN ENGINEERING AND PROPERTY SOLUTIONS October 19, 2011 Mr. Michael Charles Maximum Comfort Pool and Spa, Inc. P.O. Box 2670 Vail, CO 81658 Subject : 186 Forest Road request for special inspection of pool. Mr. Charles, This letter addresses a request for a special inspection of the proposed pool at 186 Forest Road. A special inspection for the pool structure only is not required as it is designed and will be built in accordance with the requirements of IBC 2009 Chapter 19 and ACI 318. Those structural elements supporting the fill beneath the pool will be part of a special inspection in accordance with Table 1704.9 of the IBC 2009. Sincerely, Solgreen LLC Z4 Eric McDaniel, P.E. _J R M`Qq�.F9 •O 34298 o�•� 10 -19-II ;•�� F • .•N At A /1mm111n1101, Phone: 303 - 918 -2516 1 Email: soloreen@earthlink.net 1 6732 W. Coal Mine Ave., Suite 164, Littleton, CO 80123 -4573 TRANSMITTAL FORM Revision Submittals: 1. "Field Set' of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: Attention: () Revisions Response to Correction Letter _attached copy of correction letter () Deferred Submittal FL2 Other Project Street Address: - � &,_ 1� 1- 0 (Number) (Street) (Suite #) Description / List of Changes: Building /Complex Name: ( [ C P��soay z !� 4i 0-2 6-1 ' .t. Contact Information: Company: VI� ►l (Ntt1y( �avc��( L- �.SR'� Company Address: �' d �� K 2,670 City: V` -t' State: C-,ff> Zip: ff Contact Name: I h- 9 AEL C-9 A R LI --f Contact Phone: 7 D , (�)b �z- ceecoo E -Mail X." "Lier -10, A,�G PS vkj& • C5`4 Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: Plumbing: Electrical: Mechanical: Total: -.�5o IL 4-o 1Y2 - ►� 1 • vcnc ° A1QJ,-,0 70 { e4 (7- "'a R I I ©Y/ Z ©q ( -2 u e additional sheet if necessary) Date Received: D GCE 9ME D OCT 112011 TOWN OF VAIL 01- Jan -10 .• C� Gies Architects, Inc. P.O. Box 2195 Eagle, Co 970.328.9280 (office) www.giesarchitects.com PROPOSAL FOR ARCHITECTURAL SERVICES October 7, 2011 Martin A. Haeberle Chief Building Inspector Town of Vail 75 South Frontage Rd. West Vail, CO 81657 Re: 186 Forest Road B11 -0351 Response to comments: Architectural Comments: 1. Sheet CLI -Pool barrier per Section AG 105.2 See Sheet C1.1 and L1.1 for location of pool barrier. Pool barrier that will be used is "Protect -A- Child" 48" composite fiberglass post pool fencing See spec sheet for more info. 2 door alarms will be place at the Great Room and Bed Rm #1 sliding glass doors, See C1.1 for locations Sheet A1.1 1. Proposed glazing wall comply with sections 2404 and 1609 IBC See enclosed Glass Load Resistance Report from Oldcastle Glass- Denver, CO for window #102 on sheet A1.1 2. Maximum U values required for proposed glazing per Table 402.1.1. IECC See enclosed sheet A.1. Window schedule with U vales for proposed windows. Planning 1 Comments: 1. Pool 10' -0" fromroperty line, See Sheet C1.1 and C1.2 for 10' setback 2. Front Set back 20 , side setback 15', See Sheet C1.1 and C1.2 for correct setbacks 3. GFRA and Site Coverage Calc's , See Cover Page for revised numbers Sincerely, David R. Burns AIA 11 OCT -05 -2011 WED 10:14 AM OLDCASTLE GLASS DENVER FAX NO. 3033 -1114447 P. 01/01 Glass Load Resistance Report -- Glazing Information Edge Supports: 4 Sides Glazing Angle: 90° Lite Dimensions: Width: 120 in. Height; 74.0 in. Glass Construction (Rectangular) Double Glazed Insulating Unit Outboard Lite: { Fully Tempered } Nominal Thickness: 114 in. Project Details Project Name: Location: Comments: Air Space: 0.75 in. Inboard Lite: { Fully Tempered } Nominal Thickness: 1 /tl, In. Short Load Duration Resistance, and Deflection Data Load (— 3 sec.): 21.0 psf Load Resistance: 149 psf Approximate center of glass deflection: 0,85 in. Conclusion Based on your design Information, the load resistance Is greater than t►r equal to the specified loading. Statement of Compliance Procedures followed in determining the resistance of this window glass are in accordance with ASTM E1300 -04. Disclaimer: This aaflww6 can lie ucod to determine the load remlelance of spocifind olaas types oxponed to ur iorm lateral loads of short fir long duration eupJect to the following condltlona; The otasa I; free of edge and surface damage and has seen properly alaaod in the openlno In confonTlance with the mrYlufacluror'n recommandmians. Pracoduree exist to determino load resistance for roctangular pleas easemblles that are; o. Cont1moualy supported along all four algae, o. eontlnuou:ly aupported slon0 three edges, c. Contlnuausly aupported along two parallel odgee, and d, Corttlntrousy supported gleng one odoo, - The software usor ham the responelollity, of mearling 109 Carrmct procedures for the required application ken 1119 softwdrs. The Billfnoss of members, supporting any glass edgo sholl he sufficient that under design load, edge dedectlonF -hall not oxcaed ll where L denotes that length of the eupporled edge. The manufacturer ataten that the Safety Pluc It 0.000 Polyurethane Large Mlasllo Roale ant Inlenayor In comparable to Itx> PVa Intorlayer. For other limiting oonditlons that may apply, rarer to section 5 of ASTM E13oa and local WildIna coda -, Neither SOG nor GANA guerenteea and 0619h dsc'aime any rosponsidlllty for any panloulor results rolallno to the use of the Window Glaw pealgrl 2004 6oflwgr6 Program. SOG and GANA dlsclalm any Iloblllly for any parconnl Injury or any loos or dainage of any kind, Includnd all Indlreci, speelal, or consequential damages and lost proflte, arlslno out of or ralellno to the uco of the Window Glec; Penlgn 2004 Software Program. Prepared by: on 10/5/2011 Window Glass Design 2004 - Version [1.38] Copyright 0 2007 SDG, Inc. Page 1 of 1 r. Lowdermilk /Mitchell Mechanical, LLC PO BOX 230 WOLCOTT, COLORADO 81655 970.376.2918 and 970.376.7269 CHUCK LANGSTON 10.6.11 AEC ENGINEERING AVON CO 81620 RE: ELECTRICAL LOADS FOR NEW MECHANICAL EQUIPMENT AT 186 FOREST ROAD CHUCK, WE HAVE THE EXISTING CIRCUITS, 30 AND 32 1 BELIVE THAT FEED OUR SNOWMELT PLANT AT THE BACK OF THE HOUSE. WE WILL LOAD THOSE CIRCUITS WITH APPROXIMATELY 3.2 AMPS AND 4.9 AMPS. WE COULD USE ONLY ONE CIRCUIT, BUT I PREFER TO KEEP EACH UNIT ON A DEDICATED CIRCUIT. IN THE MAIN MECHANICAL ROOM, WE HAVE THE EXISTING 5 CIRCUITS TO WORK WITH. WE WILL USE ALL FIVE CIRCUITS AS FOLLOWS: 1) 3.2 AMPS (BOILER 1 WITH PUMP) 2) 4.2 AMPS (BOILER 2 WITH PUMP) 3) 5.1 AMPS (BOILER 3 WITH 2 PUMPS) 4) 6.2 AMPS (CONTROL PANEL WITH 4 PUMPS) 5) 2.3 AMPS (FRESH AIR VENTILATION SYSTEM AND ASSOC. CONTROLS) PLEASE DON'T HESITATE TO CALL IF YOU HAVE ANY QUESTIONS. RESPECTFULLY, SHAYNE MITCHELL Lowdermilk /Mitchell Mechanical, LLC PO BOX 230 WOLCOTT, COLORADO 81655 970.376.2918 and 970.376.7269 TOWN OF VAIL 75 SOUTH FRONTAGE ROAD WEST VAIL COLORADO 81657 October 5, 2011 RE: 186 FOREST ROAD (1311 -0351) MECHANICAL SPECIFICATIONS AND SCOPE OF WORK PROPOSED. SYSTEM 1: SNOWMELT SYSTEM: THE ORIGINAL SNOWMELT SYSTEM WAS BASED ON AN OURDOOR BOILER PLANT LOCATED BEHIND THE HOUSE. A SMALL PPORTION OF SNOWMELT WAS PROVIDED FROM THE HEATING PLANT LOCATED INSIDE THE HOUSE. THAT WILL NO LONGER BE THE CASE. ORIGINAL BOILER CAPACITY AND EFFICIENCY: 78% AFUE RATING 750,000 BTUH INPUT. 402,480 NET OUTPUT. NET OUTPUT EFFICIENCY: 54% NEW BOILER CAPACITY AND EFFICIENCY: RECEIVED 93.3% AFUE RATING 798,000 BTUH INPUT. 640,299 NET OUTPUT. DESCRIPTION OF SYSTEM MODIFICATIONS: THE ORIGIBAL PLANT WAS LOCATED OUTDOORS BEHIND THE HOUSE. THE NEW PLANT IS LOCATED IN AN UNFINISHED INTERIOR SPACE APPROXIMATELY 5' FROM THE ORIGINAL LOCATION. THE NEW PLANT IS MADE UP OF (2) LOCHINVAR KNIGHT XL KBN400. THE ORIGINAL MEDIUM PRESSURE GAS LINE IS BEING UTILIZED AND THE AMOUNT AND LENGTH OF PIPING HAS BEEN REDUCED. COMBUSTION AIR IS NOT REQUIRED AS THESE NEW PRODUCTS ARE SEALED COMBUSTION. SYSTEM 2: HOME HEATING AND DOMESTIC HOT WATER GENERATION: THE ORIGINAL SYSTEM IS LOCATED IN THE MAIN HOUSE MECHANICAL ROOM LOCATED ADJACENT TO THE GARAGE AND ACCESSED FROM AN INTERIOR HALLWAY. THIS SYSTEM PROVIDES HOME HEATING, DOMESTIC HOT WATER AND A SMALL SNOWMELTED WALKWAY. THIS PLANT WILL NO LONGER PROVIDE SNOWMELT. ORIGINAL BOILER CAPACITY AND EFFICIENCY: 78% AFUE RATING 690,000 BTUH INPUT. 416,566 NET OUTPUT. NET OUTPUT EFFICIENCY: 60% NEW BOILER CAPACITY AND EFFICIENCY: 93.3% AFUE RATING. 570,000 BTUH INPUT. 457,356 NET OUTPUT. DESCRIPTION OF SYSTEM MODIFICATIONS: THE EXISTING SYSTEM IS BASED ON (2) ATMOSPHERIC MID - EFFICIENT APPLIANCES LOCATED IN THE MECHANICAL ROOM. THIS IS A HIGH TEMP SYSTEM AND ALL CAPACITY IS FIRED FOR EVEN THE SMALLEST LOAD REQUIREMENT. THE NEW SYSTEM IS BASED ON (2) HIGH EFFICIENCY (93.3% AFUE) BOILERS THAT ARE 5 STAGES EACH. THE NEW BOILERS WILL FIRE BASED ON EXACT LOAD REQUIREMENTS ONLY AND HAVE A COMMUNICATION BUS TO MANAGE A 10:1 TURN DOWN RATIO. THE EXISTING 120 GALLON INDIRECT FIRED WATER HEATER IS BEING REPLACED WITH (2) 80 GALLON INDIRECT FIRED UNITS AND WILL HAVE A PRIORITY DEMAND ON (1) OF THE NEW BOILERS. THE NEW FLUE SYSTEM WILL BE ROUTED THROUGH THE EXISTING TYPE B -VENT VIA SCH 40 PVC FOR THE FLUE AND SCH 40 PVC FOAM CORE FOR THE COMBUSTION AIR AND EXIT THROUGH THE ROOF. COMBUSTION AIR IS NOT REQUIRED DUE THE FACT THESE ARE SEALED COMBUSTION BOILERS. WE ARE HOWEVER PROVIDING A VENTILATION SYSTEM TO COOL THE ROOM IF NECESSARY. SYSTEM 3: NEW POOL, WATER FEATURE, NEW SNOWMELT FOOTAGE: THIS IS A NEW SYSTEM TO PROVIDE FOR NEW LOADS GENERATED DUE TO NEW SWIMMING POOL, WATER FEATURE REMODEL, AND NEW SNOWMELT REQUIREMENT. SWIMMING POOL AND WATER FEATURE LOAD: 175,000 BTUH. SNOWMELT LOAD: 187,500. TOTAL CAPACITY REQUIRED: 362,500 NEW BOILER PLANT EFFICIENCY AND CAPACITY: 93.3% AFUE RATING. 500,000 BTUH INPUT. 401,190 NET OUTPUT. DESCRIPTION OF SYSTEM: THIS BOILER WILL BE PLACED IN THE MAIN HOUSE MECHANICAL ROOM AND THE FLUE WILL BE ROUTED TO THE BACK OF THE HOUSE AND EXIT NEXT TO THE NEW SNOWMELT PLANT FLUES. THE PRIMARY LOOP WILL BE ROUTED TO THE NEW POOL VAULT AND THE SNOWMELT WILL BE DISTRIBUTED FROM THE MAIN HOUSE MECHANICAL ROOM. HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS, UP T094.6% THERMAL EFFICIENCY 0 ra 11U n High ERciency Water fteaters, Boilers and Pool Resters ol Lo chin var.com 0 s COMMERCIAL BOAR ON THE SMARTEST CHOICE FOR CONDENSING BOILER PERFORMANCE Th AART SYSTEM control and an f, atures, 4�t far ahead of any commercial heating boi s and deliver ltimate ease of installation and maintenance. Wit efficiency, to Ox emissions and a fully modulating burner, it i e" for today' ironmentally focused market. Fiv sing stainl el KNIGHT XL boilers are available with 39 r inputs and re kably small ace saving footprints. All are eq installation w it intake a d exhaust runs up to 100 feet usi 4C vent materi This range f choices is ideal for light -duty ap Il hotels, schools and office buildings. For higher- demand ap can be installe utilizing the built -in cascading se heatip4WaWcity. THE KNIGHT XL BOILER reflects Lochinvar's constant commitment to providing all the options you need to serve every application. i KNIGHT XLs installed ti- and commissioned by Black & McDonald •,;�- �• ADVANCED NEGATIVE REGULATION TECHNOLOGY 0/0 KNIGHT XL safety and reliably operates with supply gas pressure as low as 4 inches water column. Negative Regulation (Neg /Reg) technology automatically adjusts fan speed that ensures the correct volume and mix of fuel and air throughout the firing range. TWO-IN -ONE STAINLESS STEEL HEAT EXCHANGER A primary heat exchanger combined with a secondary heat exchanger captures flue gas heat and condenses to utilize available latent energy. The stainless steel, pH- tolerant design features a weld - sealed assembly with no G -rings or gaskets and does not require special glycol. ASME Section IV approved and stamped. FULLY MODULATING BURNER The SMART SYSTEM allows fully modulating combustion with 5:1 turndown. The burner can fire as low as 209''. of maximum input and modulates the firing rate up to 100% as demand increases. The burner is a single stainless steel assembly covered with woven steel mesh and fires in a 3600 pattern along the entire length of the primary heat exchanger. This allows the compact KNIGHT XL to exceed the capacity of units with larger multiple burners. D I RECT VENTI N G UP TO 100 FEET Sidewall Vent Termination lopKNIGHT XL offers 7 venting options and tremendous flexibility for placement of units within the building, because it permits direct -vent air intake and exhaust runs up to 100 equivalent feet using either PVC, CPVC or AL29 -4C stainless steel vent pipe. A sidewall vent termination kit is SKI $IDEWALL VENT TERMINATION SYSTEM REFINED DESIGN PUTS MORE CONTROL AND INFORMATION AT YOUR FINGERTIPS W Advanced features include: SETPOINT TEMPERATURES • MODBUS CAPABILITY (OPTIONAL) • DHW MODULATION LIMITING • DHW NIGHT SETBACK* • 0-10 V BOILER RATE OUTPUT • 0-10V SIGNALTO CONTROLVARIABLE SPEED BOILER PUMP* • 0-10V SYSTEM PUMP SIGNAL INPUT* • HEAT DEMAND FROM 0 -10V INPUT • INSTALLER CAN PROGRAM NAME AND NUMBER INTO THE BOILER • INSTALLER ADJUSTABLE FREEZE PROTECTION PARAMETERS • SEPARATELY ADJUSTABLE SH/DHW SWITCHING TIMES* • INSTALLER ACCESS TO BMS AND RAMP DELAY SETTINGS *ERCLUSIVE TO LOCHINVAR SMART SYSTEM f \00 S HE FR AT -A -GL r SCRC! . • BLUE SCREEN YELLOW SCREEN RED SCREEN Normal system Maintenance due - shows Lockout mode. operation. the installer's name and number on the display - NEW SELECTABLE CASCADE OPTIONS When multiple KNIGHT boilers are installed together, the SMART SYSTEM built -in sequencer can be set for "Lead -Lag" cascade or "Efficiency Optimized" cascade operation. LEAD -LAG CASCADE EFFICIENCY OPTIMIZED CASCADE A A A A 0 A 0 0 The "lead" boiler modulates with demand to capacity. As demand increases, additional boilers fire and modulate to capacity. This continues, with additional boilers firing and modulating to capacity until all units are operating. Every 24 hours, the SMART SYSTEM automatically shifts the lead boiler role to the next in the sequence. distributing lead -lag runtimes equally. 7 FLEXIBLE VENTING OPTIONS Direct Vent Sidewalt Direct Vent Vertical Room Air Sidewall A A A A A A A A This feature optimizes the modulation capabilities of the Boiler Plant while evenly distributing run time across all cascaded boilers. Every 24 hours the SMART SYSTEM automatically shifts the 1st boiler on role to the next in the sequence, distributing run time equally. 541ARTSYSTE61 Coscode option ollo:vs 2 - S boi ;e!c !o be se- ,oenced. Room Air Vertical Vertical w Sidewalt Air Direct Vent Vertical* Direct Vent Sidewalt* �a 'Optional Concentric Vent Kit Sold Separately ((or 400 -601 Models) a I' • MULTI -COLOR GRAPHIC LCD DISPLAY • NAVIGATION DIAL • USB PORT • ABILITYTO CONTROL UP TO THREE DIFFERENT SETPOINT TEMPERATURES • MODBUS CAPABILITY (OPTIONAL) • DHW MODULATION LIMITING • DHW NIGHT SETBACK* • 0-10 V BOILER RATE OUTPUT • 0-10V SIGNALTO CONTROLVARIABLE SPEED BOILER PUMP* • 0-10V SYSTEM PUMP SIGNAL INPUT* • HEAT DEMAND FROM 0 -10V INPUT • INSTALLER CAN PROGRAM NAME AND NUMBER INTO THE BOILER • INSTALLER ADJUSTABLE FREEZE PROTECTION PARAMETERS • SEPARATELY ADJUSTABLE SH/DHW SWITCHING TIMES* • INSTALLER ACCESS TO BMS AND RAMP DELAY SETTINGS *ERCLUSIVE TO LOCHINVAR SMART SYSTEM f \00 S HE FR AT -A -GL r SCRC! . • BLUE SCREEN YELLOW SCREEN RED SCREEN Normal system Maintenance due - shows Lockout mode. operation. the installer's name and number on the display - NEW SELECTABLE CASCADE OPTIONS When multiple KNIGHT boilers are installed together, the SMART SYSTEM built -in sequencer can be set for "Lead -Lag" cascade or "Efficiency Optimized" cascade operation. LEAD -LAG CASCADE EFFICIENCY OPTIMIZED CASCADE A A A A 0 A 0 0 The "lead" boiler modulates with demand to capacity. As demand increases, additional boilers fire and modulate to capacity. This continues, with additional boilers firing and modulating to capacity until all units are operating. Every 24 hours, the SMART SYSTEM automatically shifts the lead boiler role to the next in the sequence. distributing lead -lag runtimes equally. 7 FLEXIBLE VENTING OPTIONS Direct Vent Sidewalt Direct Vent Vertical Room Air Sidewall A A A A A A A A This feature optimizes the modulation capabilities of the Boiler Plant while evenly distributing run time across all cascaded boilers. Every 24 hours the SMART SYSTEM automatically shifts the 1st boiler on role to the next in the sequence, distributing run time equally. 541ARTSYSTE61 Coscode option ollo:vs 2 - S boi ;e!c !o be se- ,oenced. Room Air Vertical Vertical w Sidewalt Air Direct Vent Vertical* Direct Vent Sidewalt* �a 'Optional Concentric Vent Kit Sold Separately ((or 400 -601 Models) a I' KNIGHT °XL BOILER DIMENSIONS AND SPECIFICATIONS LOW VOLTAGE BACK qM KB N 701 M13 A d`r Gr O/ s Knight A Boiler, Natural Gas, 700,000 Btu /hr input, M13 firing controls A usTAsu FRONT LEFT SIDE Oft 80 399 93.3% 373 324 42-11Y 15-11Y 27-3N' 3-3/4' 20 -3/4' 11' 14" 34' 34' 2" 18 -3/4' l' 1 -1/Y 4' 4' 280 awl 100 500 93.3% 467 406 41 -1 R" 15 -111" 31 -1R' 3 -3/4' 25 -112' 21' 14" 32 -11Y 36' Y 18' 11 1 -111' 4' 4' 310 KBM01 120 600 94.6% 567 493 42 -1 /2" 15 -1/2" 36 -1/4" 3 -3/4' 25' 11' 14' 36" 32 -3/4' 5-1(1" 19-1/Y 1' Y 4' 4' 340 KBN701 140 700 94.3% 660 574 42 -111' 15 -112" 40.114" 3 -314' 29' 13' 1r 36' 32 -3/4' 3-1/4' 23.1/P 1" Y 4' 6' 370 KBN801 160 800 94.0% 752 654 42 -1/Y 15.1/2" 45 -1/4' 3-3/4' 33.114' 23' 17' 36' 32 -3/4' 3 -114' 27 -3/4' 1" 1' 4' 6' 405 Notes: Indoor installation only. All information subject to change. Change 'N" to "L" for LP gas models. STANDARD FEATURES SMART SYSTEM FEATURES > High Voltage Terminal Strip > Up to 94.6% Thermal Efficiency > SMART SYSTEM Digital Operating Control 120 VAC / 60 Hertz / 1 Phase Power Supply > Modulating Burner with 5:1 Turndown Multi -Color Graphic LCD Display w/ Navigation Dial Three sets of Pump Contacts with Pump Relays > Direct -Spark Ignition > Three Reset Temperature Inputs Low Voltage Terminal Strip > Low NOx Operation with curves for three set point temperature inputs 24 VAC Device Relay > Sealed Combustion Built in Cascading Sequencer for up to 8 Boilers > Proving Switch Contacts > Lead Lag > Flow Switch Contacts > Low Gas Pressure Operation > Efficiency Optimization > Alarm on Any Failure Contacts > ASME Stainless Steel Heat Exchanger > Outdoor Reset Control with Outdoor Air Sensor > Runtime Contacts > ASME Certified, "H" Stamped > Programmable System Efficiency Optimizers > DHW Thermostat Contacts Gasketless Heat Exchanger > Night Setback > 3 Space Heat Thermostat Contacts > 160 psi Working Pressure > DHW Night Setback > System Sensor Contacts > 50 psi ASME Relief Valve > Anti - Cycling > DHW Tank Sensor Contacts > Highly efficient, condensing design > Outdoor Air Reset Curve > Outdoor Air Sensor Contacts > Vertical & Horizontal Direct -Vent > Ram Dela p y > Boost Temperature & Time > Cascade Contacts > 0 -10 VDC BMS External Control Contact > Category IV venting up to 100 feet > Three Pump Control > 0 -10VDC Boiler Rate Output Contacts > PVC, CPVC or AL29 -4C Venting up to 100 Feet > System Pump With Parameter for Continuous Operation > 0 -10VDC Variable Speed System Pump Signal Input > Factory Supplied Sidewall Vent Termination > Boiler Pump With Variable Speed Pump Control' 0 -10VDC Signal to Control Variable Speed Boiler Pump > Smart System Control > Domestic Hot Water Pump Contacts > Other Features > Domestic Hot Water Prioritization me Clock > Time Clock > On /Off Switch > DHW tank piped with priority in the boiler loop > Data Logging > DHW tank piped as a zone in the system with > Adjustable High Limit w/ Manual Reset the pumps controlled by the Smart System > Hours Running, Space Heating > Automatic Reset High Limit > DHW Modulation Limiting > Hours Running, Domestic Hot Water > Flow Switch > Separately Adjustable SH DHW Switching Times* > Ignition Attempts > Flue Temperature Sensor > Building Management System Integration > Last 10 Lockouts > Low Air Pressure Switch > 0 -10VDC Input to Control Modulation or Set Point > Other features > 0 -10VDC Input Signal from Variable Speed > Low Water Flow Safety Control & Indication > Tem erature &Pressure Gauge P g System Pump* > Password Security > Adjustable Leveling Legs > 0 -10VDC Modulation Rate Output > Inlet & Outlet Temperature Readout > Condensate Trap > 0 -10VDC Input to Enable /Disable call for heat > Customizable Freeze Protection Parameters > Zero Clearances to Combustible Material > Access to BMS Settings through Display > Custom Maintenance Reminderwith Contractor Info > 10 Year Limited Warranty (See Warranty) *Exclusive feature, available only from Lochinvar FIRING CODES >M9 Standard Construction )M7 California Code > M13 CSD1 / FM / GE Gap (KB501- KB801) OPTIONAL EQUIPMENT. > Alarm Bell > Condensate Neutralization Kit) > Concentric Vent Kit (KB40o- KB6o1) > High & Low Gas Pressure Switches w/ Manual Reset (KB501- KB8o1) MODBUS Communication > Low Water Cutoff w /Manual Reset & Test > SMART SYSTEM PC Software > Stainless Steel Vent Kits (KB701- KB8o1) > Stack Frame } 1 1 Y 1 I =g= AON41 Patent 111111%0 Pending -- - 111"`��� High FRiciency Rater Heaters, Butlers and Pool Heater KNIGHT° BOILER DIMENSIONS AND SPECIFICATIONS - FLOOR - STANDING MODELS Models: KBN 081 -211 Model: KBN286 KNIGHT HEATING BOILER 0 Input Heating NET Made( Mi n' Max. AFUE Capacity I=B=R WBNO51 10 50 953 45 39 WBNO81 16 BO 95.3 72 63 WBN106 21 105 95.4 94 82 WBN151 30 150 95.5 135 119 WBN211 42 210 95.7 190 165 KBN081 16 80 95.3 72 63 KBN106 21 105 95.4 94 82 KBN151 30 ISO 95.5 135 119 KBN211 42 210 95.7 190 165 KBN286 57 285 96.0 260 126 I Notes: Indoor insta lit 'on only. All information subject [ SMART SYST M EATURES ,6 > SMART SYSTEM Digital Operating Contra[ > Multi -Color Graphic LCD Display with Navigation Dial and Soft Keys > Three Setpoint Temperature Inputs > Built -in Cascading Sequencer for up to 8 Boilers Lead Lag Efficiency Optimization > Outdoor Reset Control with Outdoor Air Sensor > Programmable for Three Reset Temperature Inputs > Programmable System Efficiency Optimizers Night Setback w /Overide Function DHW Night Setback w /Overide Function > Anti - Cycling > Outdoor Air Reset Curve > Ramp Delay Boost Temperature & Time > Three Pump Control System Pump with Parameter for Continuous Operation > Boiler Pump with Variable Speed Pump Control* > Domestic Hot Water Pump > Domestic Hot Water Prioritization > DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the Smart System > DHW Modulation Limiting > Separately Adjustable SH /DHW Switching Times* > Building Management System Integration > 0 -10VDC Input to Control Modulation or Set Point > 0 -10VDC Modulation Rate Output 0.10VDC Input Signal from Variable Speed System Pump* 0 -10VDC Input to Enable /Disable call for heat A FRONT A AOJUS'J�BIE� WALL -MOUNT MODELS ,6 N J 0 FLUE-/ AIR MLET SIDE 1e-,rz- Models: WBN051 -211 TOP E4�c- *wcu D G I—T J11IrOROEN _ LtRAM BOTTOM *Exclusive feature, available only from Lochinwr > High Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply )Three Sets of Pump Contacts > Low Voltage Terminal Strip 24 VAC Device Relay Proving Switch Contacts flow Switch Contacts Alarm on Any Failure Contacts > Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts > 0 -10VDC BMS External Control Contact 0 -10VDC Boiler Rate Output Contacts 0 -10VDC Variable Speed System Pump Signal Input 0 -10VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts > Time Clock > Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts Access to BMS Settings through Graphic LCD Display Maintenance Reminder Custom Maintenance Reminder with Contractor Info Installer Ability to De- activate Service Reminder Low -Water Flow Safety Control & Indication Dual Level Password Security Customizable Freeze Protection Parameters > Energy Star — QuaBfied > Up to 96% DOE AFUE Efficiency > Modulating Burner with 5:1 Turndown > Direct -Sparc Ignition > Low -NOx Operation > Feld Convertible from Natural to LP Gas > ASME Stainless Steel Heat Exchanger > 30 psi ASME Relief Valve > Vertical & Horizontal Direct -Vent > PVC, CPVC or SS Venting up to 100 feet > Factory Supplied Sidewall Vent Termination > Smart System Control > Condensate Trap > Other Features > Automatic Reset High Limit > Adjustable High Limit w /Manual Reset > Boiler Circulating Pump > Adjustable Leveling Legs (KB Models only) > Wall -Mount Bracket (WB Models only) > Zero Clearances to Combustible Materials > 12 -Year Limited Warranty (See Warranty for Details) OPTIONAL EQUIPMENT > Modbus Communication )Condensate Neutralization Kit > Flow Switch > Low -Water Cutoff w /Manual Reset & Test > Alarm Bell Concentric Vent Kit SMART SYSTEM PC Software Stack Frame FIRING CODES )M9 Standard Construction >M7 California Code ox, , TrE g /ym ILI = n ® ®O ® Patent Pending M E M B E R CS-11 AIrY ETaine> Wale. Aeuwx, Beiktb W RM AeHen DIMENSIONS AND SPECIFICATIONS I Conn. Conn. 29-1/4 15-314 NA 10-3/4 10-31 2 6-314 NA 3-1/4 4-1 2 -314 1!2 1 2 2 130 29.1/4' 15 -3/4 NA 10-3/4 10-3/4 2 6-3/4' NA 3 -1/4x V 2 -3/4" 1/1' 1 2" 2" 130 29.114° 15 -314" NA 10-3/4 0 374' 3 -1R' 5-1/f NA 3 -114' 4-1/4 2 -314 1 1 f 2' 134 19 -114x0 -374' NA 15-3/4 8-1/2' 3 -1R' 5-1 NA 8-3/4 9-31 1 -1 1 1 3 3 162 29=1/4 _ 25" NA 2 12 3-1 5-1/2 NA 13" 14 1 -i 1 1 3 —3--177 33 -1 /4 14 5-3/4 3 NF1 22 1 -3/4 6-11 NA 1 1 3 3 125 33 -1 /4' 14" 6-1/2' S 3144 -1R' 1 -112' 20 -112' 22' 1 -3/4' 6-1R° NA 1 1 3 129 33 -1 /4' 18' 12 -114 1 11 R 10" 1 -3/8° 21 -1/4' 23' 1 -3/4" 12' NA 1 1 3 3 157 33-1% 12 -1/4' 161 15 3/4' 14 1/4' S -1/4' 21 -1/4' 23° 1 3/4" 16 114° NA 1 1 3 3 111 42 -1/4 - - 19 -3/4' 12 -3/4 13 -1/2' C _ 2' 34" 31' 11 -3/4 - 4-1/4" NA 3/4' 1 -1 /4' - 4 4' 224 to change. Change 'N' to 'L "(or LP gas models. 0— STANDARD FEATURES *Exclusive feature, available only from Lochinwr > High Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply )Three Sets of Pump Contacts > Low Voltage Terminal Strip 24 VAC Device Relay Proving Switch Contacts flow Switch Contacts Alarm on Any Failure Contacts > Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts > 0 -10VDC BMS External Control Contact 0 -10VDC Boiler Rate Output Contacts 0 -10VDC Variable Speed System Pump Signal Input 0 -10VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts > Time Clock > Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts Access to BMS Settings through Graphic LCD Display Maintenance Reminder Custom Maintenance Reminder with Contractor Info Installer Ability to De- activate Service Reminder Low -Water Flow Safety Control & Indication Dual Level Password Security Customizable Freeze Protection Parameters > Energy Star — QuaBfied > Up to 96% DOE AFUE Efficiency > Modulating Burner with 5:1 Turndown > Direct -Sparc Ignition > Low -NOx Operation > Feld Convertible from Natural to LP Gas > ASME Stainless Steel Heat Exchanger > 30 psi ASME Relief Valve > Vertical & Horizontal Direct -Vent > PVC, CPVC or SS Venting up to 100 feet > Factory Supplied Sidewall Vent Termination > Smart System Control > Condensate Trap > Other Features > Automatic Reset High Limit > Adjustable High Limit w /Manual Reset > Boiler Circulating Pump > Adjustable Leveling Legs (KB Models only) > Wall -Mount Bracket (WB Models only) > Zero Clearances to Combustible Materials > 12 -Year Limited Warranty (See Warranty for Details) OPTIONAL EQUIPMENT > Modbus Communication )Condensate Neutralization Kit > Flow Switch > Low -Water Cutoff w /Manual Reset & Test > Alarm Bell Concentric Vent Kit SMART SYSTEM PC Software Stack Frame FIRING CODES )M9 Standard Construction >M7 California Code ox, , TrE g /ym ILI = n ® ®O ® Patent Pending M E M B E R CS-11 AIrY ETaine> Wale. Aeuwx, Beiktb W RM AeHen �, PmswK£ ;,E6vL*xo(t a/I MEDlufn PRsSSt)IZE 'rdrRL. 3 Of 2-n MF7Et, TRANSMITTAL FORM Revision Submittals: 1. "Field Set' of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: /-035 1L'0 Project Street Address: (Number) (Street) Building /Complex Name: Contact Information: Company: Company Address: City: Contact Name: Contact Phone: E -Mail State: Zip: Attention: () 5ovisions (vponse to Correction Letter L�iG G)4AINJAW _attached copy of correction letter () Deferred Submittal Other Description / List of Changes: (Suite #) 1 �i-EC LT �� • 4 Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: $ Plumbing: $ Electrical: $ Mechanical: I Total: i i r 3 00C-' ['IC -LO SET- oyr= ©sect, SEr Oil` ove oFFICE Sir F2 035/ �uE SEr Fo/r� Pte, gl! -Oyler (use additional sheet if necessary) Date Received: ��IC�[E Ub[Er OCT 07 2011 IU TOWN OF VAIL 01 -Jan-10 Department, of Community Development 75 South Frontage Road Vail, Colorado- . &i.s57' Tel: 970- 479 -21 2F " n Fax: 970 -479 -2 452 Web: wwvi.vailgov.coir, a< Development Review, Coordinator TRANSMITTAL FORM Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: 3tl -0351 Attention: Project Street Address: I _L o (e rnRESTORD (Number) (Street) (Suite #) Building /Complex Name: Contact Information: Company: ]Ml%X. 1• mu- l o FORT POOL SPA Company Address: PD BOX aG7C) City: VA I L, State: 0 -Zip: Contact Name: -1 r-A. heL C<4IAP - LeS ` Contact Phone: -1 C.) -91D q - g000 ( ) Revisions ( ) Response to Correction Letter _attached copy of correction letter ( ) Deferred Submittal (wY`Other TO -A0 LAS 6 CoRpACT1 QiJ Description / List of Changes: _gaWK W VALU inpm 2EmouEn _I'Ro,m THIS REZMiT To MEW Pzjzmlr E FoR =--A, i0ja(j WAU lJbzr; �JEw PE2w►Ir- Is A,11- DyI2 E -Mail Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) g [� K Building: $ 1 tA to —I �rz250 L-`5 (use additional sheet if necessary) Plumbing: $ Date Received: Electrical: $ Mechanical: $ l D V lU f Total: $ n 01- Jan -10 TOWN OF VAII/ Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 1 a 40 ForzF_sr- Ra> (Number) (Street) (Suite #) Building /Complex Name: Contractor Information I P Project #: C (?� << - 0 -1 '� � DRB #: 1 1 0 3(og Ckr-D) Building Permit #: S l I- D 35 1 _ Lot #: Block # Subdivision: Business Name: 1" t A X I to VM L&M-PDQ-7- GAL SEN R� a�C 2 (o ?o giao O� `�,_ L /work Class: New ( ) Addition ( ) Alteration ( ) Business Address: �l Y� City :r' 93 (& r State: CO Zip:� Type of Building: Contact Name: M (COAF 1 J4 Q,�� S Single - Family (X) Duplex ( ) Multi - Family ( ) _ _ _ Commercial( ) Other( ) Contact Phone: 9 %0 " 904' y 000 Wa fZ��� 1 ACAS 1%1L• '-'�'1 Work Type: Interior ( ) Exterior (>Q Both (X) _ Contact E -Mail: Valuation of Work Included Plans Included Work Owner/ Owner's Representative Signature (Required) Electrical (X)Yes ( )No (X)Yes ( )No Applicant Informationnn�� Mechanical (X)Yes ( )No ( )Yes (X)No Z32tS� Q Applicant Name: ' i IVI IC,AAt L Cit Ae.LE S Plumbing (X)Yes ( )No ( )Yes (N)No DOD°L° Applicant Phone: �7�' �� " Li 000 Building ()<)Yes ( )No ( \.)Yes ( )No 67 y o0 Applicant E -Mail: iM G MeeLg S G A4,ASVA(L Cod Value of all work being performed: s_$ 35' ,s4-9 00 (value based on IBC Section 109.3 & IRC Section 108.3) Project Information Owner Name: Electrical Square Footage _ Parcel #: -?-(C l - 0-71 -1 5-CO (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us /patie) Detailed Scope and Location of Work: ?, E;-M 0 j)A-r) DiQ oF FX I ST'1k)(,e RATIO/ A Dou) 4.. r _ M• ♦ fu A - For Office Use Only: Fee Paid: Gn IS27- _�eceived From: ✓`t';I �Yw'►'�CiV -tt-� �'�l� Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Date Received: Yi r . C.'O,k CEC�CE[IW D SEP 15 2011 01- Jan -1 l TOWN OF VAIL ?' W N,01 VI-a ,/ BUILDING PERMIT SUBMITTAL REQUIREMENTS Residential additions /remodels (1/2 family IRC buildings) ** *Return this form with your application * ** a� 2 sets of plans required for decks ❑ 3 sets of plans required for interior remodels ❑ 4 sets of plans required for additions V Supply DRB application number (i.e. DR13090001) or copy of DRB Action Form L-` Architect stamp required on architectural plans if prepared by architect. Engineer's stamp required on all sheets of structural plans V Site plan required if any exterior work is proposed ❑ Asbestos project checklist & testing results c5" Floor plans for the unit showing all proposed work. Clearly show new, existing and 15ITT —PLA demolished walls. Provide a complete floor plan for each level of the building where work is proposed ❑ Exterior elevations with all exterior materials shown if any exterior work is proposed. For deck additions, show guardrail requirements. ❑ Roof plan and building cross section required for any additions. Show all insulation R- values at walls /floors /roof. Show class A roof covering material for any new roofs per TOV requirements ❑ Window schedule required for additions, or window replacements. Include U -value and safety glazing requirements. ❑ For additions, include energy code compliance forms (Rescheck) and heat loss calcs http: / /www.enerpycodes.gov ` ❑ Structural plans for any proposed structural work (stamped and signed by engineer). Complete foundation and framing plans ❑ Mechanical plans required for all proposed mechanical work. Show bath fan locations, size, location and efficiency of any heating equipment and venting termination locations o Show locations, types and venting of all proposed fireplaces ❑ Plumbing plans for all proposed plumbing work. Include gas piping and sizing plan Electrical plans for all proposed work. Include electrical power and lighting plans, panel schedule and load calculations Notes: t4 =o h1J 1 L4 i, W&P- kL- 04-D : l G t6AXc1 UN 17-S FACDev \BUILDING \checklists \IRC construction 022410.doc 06 -11 -2012 Inspection Request Reporting Page 10 4:27 pm Vail, CO - C tv Of Requested Inspect Date: Tuesday, June 12, 2012 Site Address: 186 IF RD VAIL A/P /D Information Activity: B11 -0351 Type: COMBO Sub Type: OTHER Status: APPROVED Const Type: Occuppancy: Use: R -3 Insp Area: Owner: SNOW FOREST CHALET LLC Contractor: MAXIMUM COMFORT POOL & SPA INC Phone: 970 - 949 -6339 Description: RENOVATION OF EXISTING PATIO, ADDING OUTDOOR POOL RENOVATION FO EXISTING SPA MECHANICAL AND SNOWMELT BOILERS. ADDING 46 SQUARE FEET ENCLOSING PARTIAL EXTERIOR DECK. REVISIONS TO SITE RETAINING WALL. Requested Inspection(s) Item: 390 MECH -Final Requestor: MAXIMUM COMFORT POOL & SPA INC Comments: 376-7269. Assigned To: J GON Action: Time Exp: Inspection History Item: 20 BLDG - Foundation /Steel ** Approved *" 11/14/11 Inspector: JRM Comment: PAD FOR VAULT ONLY Item: 10 BLDG - FOOTING 12/05/11 Inspector: sgremmer Comment: slab on grade Item: 120 ELEC -Rou h 12/05/11 Inspector: sgremmer Comment: conduits under slab Item: 110 ELEC - Service Item: 130 ELEC- Conduit Item: 220 PLMB - Rough /D.W.V. '* Approved ** 11/23/1 T Inspector: JRM Comment: WATERLINE 100 # AIR TEST Item: 200 MECH -Rough ** Approved ** 11/04/11 Inspector: JRM Comment: PARTIAL MECH ROUGH. VEN 11/23/11 Inspector: JRM Comment: SNOW MELT MAINS 100 # AIR 12/02/11 Inspector: JRM Comment: SNOW MELT POOL DECK 100 Item: 240 PLMB -Gas Pipping ** Approved ** 11/23/11 lns ector: JRM Comment: 3 L1NES 20 # AIR TEST Item: 250 PLMB -Pool /Hot Tub Item: 410 Special Inspect - progress rept Item: 30 BLDG - Framing Item: 50 BLDG - Insulation Item: 60 BLDG - Sheetrock Nail Item: 420 Special Inspect -final rept Item: 22 PLAN -ILC FRAMING Item: 390 MECH -Final Item: 290 PLMB -Final Item: 542 PLAN -FINAL Item: 190 ELEC -Final Item: 90 BLDG -Final Requested Time: 11:30 AM Phone: 970 - 949 -6339 Entered By: JMONDRAGON K Action: AP APPROVED Action: PI PARTIAL INSPECTION Action: PI PARTIAL INSPECTION Action: PA PARTIAL APPROVAL Action: PI PARTIAL INSPECTION TS THRU CHASE ONLY INSPECTED Action: PA PARTIAL APPROVAL TEST Action: PA PARTIAL APPROVAL # AIR TEST Action: AP APPROVED REPT131 Run Id: 14545 {'j-%n�,TII- OqSq 10 -31 -2013 Inspection Request Reporting r-ayv 4 21 m Vail CO C .... Of A/P /D Information Activity: Const Type: Owner. Contractor: Applicant: Description: Comment: Comment: Comment: Comment: Comment: Comment: Comment: Comment: Comment: Comment: Comment: Requested Site AddrDess: 186 aFaREST RD VAIN 2013 B11 -0351 Type: COMBO Occupancy: SNOW FOREST CHALET LLC MAXIMUM COMFORT POOL & SPA INC SNOW FOREST CHALET LLC RENOVATION OF EXISTING PATIO ADDII ewnnAi Anin enInUlnAGI T RC'l11 FRS Sub Type: OTHER Status: ISSUED Use: R -3 Insp Area: Phone: 970- 949 -6339 ATION FO EXISTING SPA ENCLOSING PARTIAL D TO BIN D -1, PW AND RACHEL 1PP FOR THESE CHANGES SUBMI I I LU A I Amt innc�. vnnvr���. -m and sprinkler system shall be modified for interior addition. - MVAUGHAN imme$nts by email returned to C-3 - MHAEBERLE p VED RESPONSE TO CORRECTIONS. R�UTED TO BIN F 1oL(BUNDLED DRHOADES ORIGINAL SETS) VEAPPLICATION. ROUTED TO BW C-AND RCHELL ANDEFIIRE.P DRHOADES DRHOADES has for review - MHApE�BERLE g g pp IVED roved SS return F REV SIONS SHOWING CHANGING THEMECHANICAIL VAULT L FROM POURED RETE TO BLOCK WALL. THICKENED SLAB FOOTING. ROUTED TO BIN A -2. - DRHOADES IVED A LETTER FROM SOLGREEN ENGINEERING AND PROPERTY SOLUTIONS (VIAL MICHAEL LES OF MAX. COMFORT�STATING THAT A SPECIAL INSPECTION OF THE POOL IS NOT IRED. STRUCTURAL EL MENTS UNDER THE POOL WILL. SCANNED DOCUMENT AND ED TO MARTIN FOR HIS APPROVAL. - DRHOADES set (not approved) moved to C -3. - RFRIEDE TCP rn_cad6ctions routed to Rachel Dimond - BGIBSON Item: 542 PLAN -FINAL Requestor: MAXIMUM COMFORT POOL SPA INC CsigneedeTo: Action: AP APPROVED Item: GRUTHER Time Exp: -,4j ate.. Item: Requestor: 90 BLDG -Final MAXIMUM COMFORT POOL & SPA INC Comments: 331 -1650 Assigned To: JMONDRAGON Time Ex Action: p: Item. 290 PLMB -Final Requestor: MAXIMUM COMFORT POOL & SPA INC Comments: 331 -1650 Assigned To: JMONDRAGON Time Ex Action: p: — Requested Time: 08:00 AM Phone: 970- 949 -6339 Entered By: JMONDRAGON K II.1.13 Requested Time: 09:00 AM Phone: 970 - 949 -6339 Entered By: JMONDRAGON K Requested Time: 08:30 AM Phone: 970 - 949 -6339 Entered By: JMONDRAGON K Inspection History Item: 20 BLD11 /14/11 Ins /pSctolr: JRM Approved " PAD FOR VAULT ONLY Action: AP APPROVED Item: Comment: 10 BLDG - FOOTING 12/05/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: slab on grade Item: 120 ELEC -Rough 12/05/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: conduits under slab 06/29/12 Inspector: sgremmer Action: PI PARTIAL INSPECTION from meter to street will do street cut in September Comment: underground Item: 110 ELEC - Service Rem: Item: 130 ELEC - Conduct roved " 220 PLMB- Rough /D.W.V. " App REPT131 Run Id: 14724