Loading...
HomeMy WebLinkAboutA11-0051�l'OWN OF VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 VAIL F[RE DEPARTMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Job Address: 291 BRIDGE ST VAIL Location.....: all of Plaza Lodge Parcel No...: 210108262001 Project No : OWNER PLAZA LODGE ASSOCIATES LTD PO BOX 5664 VAIL CO 81658 APPLICANT SUPERIOR ALARM & ELECTRONICS PO BOX 4910 09/27/2011 Permit #: A 11-0051 Status . . . : ISSUED Applied . . : 09/27/2011 Issued . . : 10/20/2011 Expires . .: 04/17/2012 09/27/2011 Phone: 970-926-8788 210 EDWARDS VILLAGE BLVD A108/A109 EDWARDS CO 81632 License: C000003083 CONTRACTOR SUPERIOR ALARM & ELECTRONICS 09/27/2011 Phone: 970-926-8788 PO BOX 4910 210 EDWARDS VILLAGE BLVD A108/A109 EDWARDS CO 81632 License: C000003083 Desciption: scope of work letter Valuation: $2,483.00 ******�**++*�**��***�*+�*���*****a***r*��******rra*�***++*+*a*�****� FEE SU MMA R Y►*+�*���**r����a***r*�*r***+t�+►***++*�*►*��*s**+***+**a■ Electrical---------> $o . oo To[al Calculated Fees--> DRB Fee---------> $381.11 $o.00 AdditionalFees----------> ($165.00) Investigation----> $o . oo Total Permit Fee--------> W i I I Cal I---------> $ z 16 . 11 $o . 00 Payments------------------> $216. 11 TOTAL FEES--> $381. 11 BALANCE DUE--------> $0 . 00 *�###��#*+k*#+k��###�4*#####**#�4*�Y+k**�t#**�##****#�#�*�I:*R��M�KR+Fi#*�3**+k*�i###*########�###*####t*#*+k#��*##k##��**��#M�*�#�##�k*#*##*�vk*4*#*#**+k Approvals: Item: 05600 FIRE DEPARTMENT 10/03/2011 mvaughan Action: AP *.«**..*�*+.�..�..*��..>�+����.�++�*�*�**.*»�.:++,...+,......,:.*.***..+**..**.��**..»*�*�.�**+,:**....+�...*.**���*:*.......+�*.+*+.++�.�.�.*. CONDITIONS OF APPROVAL *�*.*...**.��,.�, *.**�**..*.*�**.�#�.*...*�..*...*..*»,�«,:..*.#�,����.*,:.*,*����,�*...*»*�.�.*.����*�..�..�..�..*��*.�*.�.�*#�*�..*...**.*��,.. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN AJ�VANCE BY TELEPHQNE AT 970-479-2252 FROM 8:00 AM - 5 PM. SIGNATURE OF O,�UNE�dR CONTRACTOR FOR HIMSELF AND OWNEF *******************+**********************************************+++****+**************+*** TOWN OF VAIL, COLORADO Statement ******�*****+******************************************************************************* Statement Number: R110001512 Amount: $216.11 10/20/201110:29 AM Payment Method: Check Init: SAB Notation: 11656 - SUPERIOR ALARM ----------------------------------------------------------------------------- Permit No: Al1-0051 Type: ALARM PERMIT Parcel No: 2101-082-6200-1 Site Address: 291 BRIDGE ST VAIL Location: all of Plaza Lodge Total Fees: $216.11 This Payment: $216.11 Total ALL Pmts: $216.11 Balance: $0.00 *�***********************+******************+********�+*********�*****************�********* ACCOUNT ITEM LIST: Account Code -------------------- PF 00100003112300 Description Current Pmts ------------------------------ ------------ PLAN CHECK FEES 216.11 ----------------------------------------------------------------------------- FIRE ALARM PERMIT Commerdal and Residential Fire Alarm shop drawings are required at the time of application submittal and must induded information tisted on the 2nd page of this form. Applicatlon w(II not be aaepted wfthout this fnformation. .__ _ _.__ __._. _..__ _. _ _.. ...._ Project Street A/d�dress: Office Use: ��_ IJI� i d �1^CC� Project #: ��11 � U�'�` (Number) (Street) (Su te #) � � ���Q / ,�J�C Building Permit#: _` _ BuildinglComplex Name: _ w(�U �j '�1 Alarm Permit #: 17'[ �'v � � ( Contractor Infortnation: Company: J�' UI�Y'lo►^ /�larm Gu►�d ��GCiTonN Company Address: 2.� � F-d �ard s 1f �! 1��Q- �� S �iry: �wards State: �� zip: 11032 Contact Name: �lndu �.L� Contact Phone: _ q 70 - g Z lv - 8 788 E-Mail �'•lYlRU , 5ur�e�^ioY'a �arr►�Gn •C:OY'►'1 Town of Vail Contractor Registration No.: i� � Q X Contractor Sig ture (required) Property InformaUon Parcel #: Z I O�(� � 2LD 2OO �" 0� 2 (For parcel #, contad Eagle County Assessors Office at 970-328-8640 or visit www.eagtecounty.us/patie) Tenant Name: '1' I A ZA L.�d Qe Owner Name: Compiete Valuation for Fire Alarm Permit: Fire Alarm $: � �,,� � � Q�; Lot #: _ Block # _ Subdivision: Detailed Description of Work: 5Co P e o-� W�rk IC�I'G1'' a�ach�d (use additional sheet if necessary) Does a Ftre Alarm Exist? Yes� No () Does a Sprinkler System ExistT Yes,� No () Work Class: New ( ) Addition ( ) Remodel ( ) Repair� Retro-Fit ( ) OtFier ( ) Type of Building: Single-Family ( ) Duplex ( ) Multi-Family ( ) Commercial � Restaurant ( ) Other ( ) _. .... ._._... __ _ . __..... _... _.._.._ _. __..___.. Date Received: D � � � 0 V � SEP 2 2 2011 't�WN OF VAIL zs-M.,.-os �*, Su �rior f�1�rm �.. R . �. �t Fl�c�ron�cs Security, Fire, CCN, Access Control, Custom AudioNideo, and Automation September 22, 2011 Vail Fire Department Attn: Mike Vaughan 75 South Frontage Road Vail, CO 81657 Re: Plaza Lodge 291 Bridge St. Vail, CO Deaz Mike, Please find included a permit application for a monitored fre system replacement of the Silent Knight 5207 commercial fire system at the above address. Current alarm panel has an unresponsive keypad. It will be replaced with SK-5208, which is the replacement version of 5207. Current and load capacities are nominal and should not affect operation in the current configuration. Battery and voltage drop calculations will not be affected by the scope of work due to no changes to any of the circuits. These changes are in compliance with a11 NFPA fire codes. Existing devices will be compliant with the new panel. Please contact me with any questions regazding this permit. We appreciate your attention to this matter. Sincerely, -�,-��.�-- ��uv Daniel Dimitrov NICET II Certified Fire Alarm Technician Certificate # 119879 Expiration: 7/1/13 Post Office Box 4910 ♦ Edwards, Colorado 81632 ♦ Phone (970} 926-8788 ♦ Fax (970) 926-8790 www.superioralarmw.com � adminQsuperioralarmco.com SILENT KNIGHT by Honeywell Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panei with built-in UL listed communicator designed for applications requiring smoke detection, manual puli stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user fiendly tactile keys. The basic unit offers 10 zones of initiation and is expandabie up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the pertormance to handle your installation. Features • 10 zones, 8 Class B(Style B) and 2 Class A(Style .D) or Ciass B(Style B) zones, expandable to 30 zones • Supervised zone expanders and I/O modules can be mounted remotely from the main cont�ol panel • Event History Buffer (150 events) with date/time stamp • All zones are compatlble with 2- or 4-wire detectors • 8 selectabie/programmable output pattems for notification appliance circuits • Built-in Digital Ala�m Communicator Transmitter (DACT) • 4 Notlflcation Appliance Circuits • 4 programmable general purpose relays • Programmable smoke verification, pre-alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms • Programmable from the built-in control panel touchpad, remote annunciator, or Windows� SKSS downloading software • Direct connect port for on-site upldownloading with Windows� SKSS downloading software • Built-in walk test feature • Single or dual interlock water releasing capability • Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operaGon of the reset and silence functions • Programmabie AC trouble relay Built-in synchronization for appliances from AMSECO�, Gentex�, Faraday, System Sensor�, and Wheelock� Programmable date settings for Daylight Saving Time Clock source setting options for 50 Hz, 60 Hz, or intemal (uses the panel's intemal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms � 60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16' (8.73 cm) with 5/8" protruding Overall Dimensions: Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm} Operating Temp: 32° to 120° F (0° to 49° C) Humidity: 10 - 93% noncondensing Optional Accessories • SK-5235 LCD Remote Annunciator • SK-5217 10 Zone Expander (2 max. per system) • SK-5280 Statua Display Module (8 max. per system) • 7181 Fire 2one Converter • 5220 Direct Connect Module • 5824 Serial/Parallel Printer Interface Module SK-5208 • SKSS Downloading Software • Plex-2 Door Option Listings and Approvals • UL Usted • CSFM Listed • MEA approval 429-92-E Vol. XIII Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contairt a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabied as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 2 Class A (Style D) or Class B (Style B Initiatian Circuits 8 Class B (Style B) Initiation Circuits To AC Telephone Line 2 Direct Cbnnect For On-Site Programming Programmable Form C Relays Notification Appliance Circuits 5235 Remote Annunciators SBUS Devices 5280, 5217, & 5824 S��,I, This document is not intended to be used for InstallaUon purposes. We try MADE IN AMERICA to keep our product infortnatlon up-tadate and accurate. We cennot cover ICNIGHT all specific applicetions or antidpate all requirements. All specificadons are FORM# 350318 Rev C � subject to change without notice. For more information, contsct Silent m 2010 Honeywell intematlonal Inc. by NoneyWel) �ight 12 Clintonville Road, Northford; CT 08472=1610 Phone: (800) 328-0103, Faz: (203) 484-7118. www.silentknight.com Model 5207 Fire Control Panel with Digital Communicator and Accu-Zone� Your All-In-One Answer For Fire Protection. The Model 5207 is an all-in-one fuseless local evacuation control panel and digital communicator designed for applications requiring manual fire alarm, automatic fire alarm and water flow for sprinkier supervision. The basic unit offers fire alarm for one to eight zones, expandable to 16 with the optional 5210 expansion module. It is compatible with both finro- and four-wire smoke detectors. Compact, easy to install and service, it delivers the features you'd expect to find in fire systems costing much more. F��� __ 4 forrn C Relays: 24 Volts Q 2.5 amps resistive • Eight zones, 6 Class B(Style A) and 2 Class A(Style D). 8 expander zones and Class B(Style A). Zones are interchangeable using the Model 7181 Zone Converter. • UL, FM, MEA (BSA), CSFM listed and Approved. • Event Memory. • Fuseless design reduces service time. • 24 VDC power supply. • Compatible with 2- and 4-wire smoke detectors as well as water flow and sounding devices. • ANSI cadence pattem output. • Four programmable (Style Y) supervised signal circuits, including steady, pulse and temporal. � Programmable smoke veriflcation, pre-alarm delay,_and cross-zoning can minimize false alarms. • Four general purpose relays (Form C 24 V at 2.5 A resistive). • Built-in approved digitaf communicator with UL required priority reporting. • Flexible programming capabilities including up/downloading and use of remote annunciator. • Accu-Zone� diagnostics facilitate local and remote troubleshooting. • Walk Test. SZD% Spedficati0ns Operatlnp Voltage: 24 VDC Primary AC: 120 VRMS (� 60 Hz 2A Total DC Load: 5A Q 24 VDC Current: Standby 12p mA Alarm 700 mA (max) Dimensions: 16' W x 26.4" H x 4' D (40.6cmWx67cmH x 10.2 cm D) Operating Temperature: 32°F to 120°F (0°C to 49°C) Indlcator Lights: AClDC (Green) ON=System running on AC Flashing=0n DC Power Alartn (Red) ON=Supervlsory Alarm Flashfng=Fire Alarm Trouble (Yellow) ON=Trouble Condition OFF=No Troubles Silence (Yellow) ON=1f trouble or alarm has bee� silenced Memory (Yellow) ON=if an Alarm is reset Set Made Report (Yellow) ON=1f panel is in test or P�'o9rem mode Flashing=Panel reporting a� Model 5207 Fire Control Punel with Digital Communicator and Accu-Zone� Optional A�ooeasories Model 5230 Remote Annunciator This 4-wire, 16-zone remote annunciator English-language is easy to operate. Its fourteen function keys can perform the same operations as the main system annunciator, including silencing, resetting, and the displaying af alarms, troubles and alarm memory. The Model 5230 can be used to Model 4180 Status Display Module The 4180 provides 16 outputs to give alarm and trouble conditions by zone. Two units can be connected to annunciate all 16 zones on a 5207 control. The 16 outputs can be used to drive LEDs or a graphic annunciator. (Non-supervised) program all programmable options and Model 7181 Fire Zone Converter with the use of access codes prevent Gonverts Class B zones to Class A and unwanted tampering. vice versa. Zone Expanslon Model 5220 Direct Connect Module The 5210 adds eight additional Class B Used for city box and polarity reversing (Style A) zones to the 5207, enablin9 direct wire applications. use of both 2- and 4-wire smoke Model 5530 Downloading Modem SIA format modem for remote programming the 5207. 5541 Downloading Software For remote programming the 5207 with an IBM or compatlble personal computer. Requires a 5530 modem. The modem and soflware can be purchased as a package, order P/N 5561. 5260 Printerinterface Allows connection of a standard computer printer to provide a printed record of the 5207 system activity. (Printer not supplied.) detectors. Engineering Spedfiartions The contractor shall prpvide a complete electrically supervised flre alartn and communications system. The system shall contaln a flre alartn canVoUcommunicator end panel to supervise and operate heat and product of combustion detectbn devkes, alartn slpnal deNces, visual annunelatw and an integral dlgital communlcator to transmtt flre elartn and supervlsory signals to e central sfation. The controUcommunlcaror shaA be UL Iisted w FM approved for under NFPA 72 for Central Statbn, Local Protectfon, Remote Signalinp, and Auxiliary Signaling standards. It shall provide power and control for eight supervised detedbm m�es, tour aupervised alarm signal circuits and a dual phone Ilne digital communiwtor. The control/communicator shaN be expandabie to sbcteen supervised detection zones and shall be able to commun�ale to a centrel staUon fn SIA, SK FSK1, SK 4l2 or Radbnics BFSK iwmats. The controUcommunicator aheil be model 5207. There shall be tuvo Class A and six Clasa B detection zonea. They shall accommodate heat detecWrs, products ot combusdon detectors, manual pull statbns, sprinkler flow switches and gace valve supervisory switches intertnaed es permitted by NFPA 72. Products of combustbn may either be 2- or 4-wire and shall be aoes Heted by UL for use on the syetem. The detecbom m�es aAall be programmed to (1) be cross zorled so that lwo Indlvidual mnss must sense producla of combustlon, (2) automaticalry reaet a detectw to verify that products of combustbn exist, (3) aee a single detector in alarm before the alarm is sounded and a sipnal is transmitted W the eentral siadon. There shaN be four 1 amp supervisad (Style Y) alatm signal dreults. They shall cauae the notlfiratbn appliances to ring ateadylpulsing/temporel throughout the premlaes unUl reset or silenced. The control ahail be equlpped with four auxiliary relays thaf ahall be programmed to operate on (1) pr�alarm, (2) famper alarm, (3) speaal alartn, (4) tire elarm, (5) trouble, (8) no-silence, (7) alerm by specific zone (7-18). The relays shall remain energaed untll the panel Is sllenced, reset or ihe trouble condition Is deared. unless'no-aile�ce' is selacted. The control/communfcator shall havs en Integral annundator to Indicate sequentielly zonea in trouble and ayatem functbns. LEDs shall augment the display W make dear to an operator the syatem stetus. Am Integral Wuchped shall be provided w operate end interrogate the system. Vttal operetlons such as alam� apencing or reset shell be simple and obvioua to an operetor. Authorizetbn pasa eodea may or may not be used. The controUcommunicata ahall have the capability W aupervlse two telephane Unes, seize ihe phone Iine, and send lhe alarm signai on one or both Ifnes without the addftion of any more equlpment. It shall sound a bcal Vouble sipnal If the telephone service Is interrupted ta bnger that 45 seconds and tt shall transmH a signal indiceting the bss oi phone Ilne aervice W the centrai stetlon over the remaining phone Iine. A sipnal shall also be transmitted indicating the reatoral of phone aervice. The oontroVoommuNcator shall be able to report the bsa of either phone Ilne without regard to wh�h Ane feiled initielly. If both Iines feil, a bcel aipnal shall sound. The oonVOUcommunicator shall have the abiilty to aend a test slgnal to the central statbn every 24 hours. the test sipnel.shall be able to be transmitted at e spedNc Ume of day or niyhl by setting a progrem feature wlthin the penel. The alarm signels transmitted to the eentral statbn shatl indketa which of the eipht zones fs in alarm and which zones ere In Wuble; depending on which fortnat Is used. Restoral from alarm a froubb sipnab shall also be transmilted by zone. The controUcommunicetor shaN be eapable oi oommunicatlng W Slient Knight, Radionkx a Ademco cenUsl statbn receivers. � 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 Wodd Wide Web: http://www.sflentknight.com MADE IN AMERICA FORM# 350376, Rev. 12/98 Copyright O 1998 Silent Knight Superior Alarm & Electronics, Inc. PO Box 4910 210 Edwards Village Blvd, A108 Edwazds, CO 81632 Description Replacement Fire Panel SK-5208 Replacement Annunciator SK-5233 Labot: Alarm System Labor: Test & Inspecdon Permit Fees This estimate is for the replacement of tt►e compnercial fire panel at the Plaza Lodge. T'his replacement is being mandated by the Vail Fire Department, and is due to a motherboard malfunction with the onboazd keypad. The es6mate includes material and labor needed to complete the replacement of the fire panel, and the testing of a portion of the building in accordance fire code. Sales Tax - Eagle County & CO State Thank you for allowing us the opportunity to bid your project. Signature: Estimate Date Estimate # 8/9/2011 61379 Project PLAZA Qty Rate Total 1 1,143.00 1,143.00T 1 215.00 215.00T 6.5 90.00 585.00 6 90.00 540.00 1 I 388.06 Total 4.40% 388.06 59.75 52,430.81