Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B11-0374
NOTE: THIS PERM/T MUST BE POSTED ON JOBSITE AT ALL TIMES r` ������ Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0374 Project #: PRJ11-0494 Job Address: 1230 WESTHAVEN CIR VAIL Applied.....: 09/27/2011 Location......: UNIT B Issued.. . : 10/13/2011 Parcel No....: 210312107015 OWNER BRADSHAW, DAVID C 09/27/2011 65 CENTRAL PARK W UNIT 15-B NEW YORK NY 10023 CONTRACTOR EVANS CHAFFEE CONSTRUCTION G 09/27/2011 Phone:970-845-0466 MICHELLE EVANS PO BOX 8266 AVON CO 81620 License:C000003077 APPLICANT SNOWDON AND HOPKINS,ARCHITE 09/27/2011 Phone:970-476-2201 PO BOX 3340 VAIL CO 81658 License: C000001763 Description: REMODEL OF EXISTING WOOD DECK AND REPLACEMENT WITH NEW STONE/PAVED TERRACE WITH RETANING WALLS,FIREPLACE AND FREE-STANDING SPA UNIT.REPLACEMENT OF EXISTING WINDOW UNIT AT KITCHEN Occupancy: R-3 Type Construction: V Valuation: $82,500.00 .,......_.+...................,,...,,....,.,.....................,................. FEE SUMMARY ..........,.�...�.......,.......__.,..,........,..........,..................., Building Permit-----------> $874.75 Bldg Plan Check----------> $568.59 Use Tax Fee-----------------------> $1,450.00 Electrical Permit---------> $230.00 Elec Plan Check-----------> $149.50 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $300.00 Mech Plan Check---------> $75.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $15.00 Plmb Plan Check---------> $3.75 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $15.00 TOTAL PERMIT FEES-------------> $3,681.59 Payments------------------------------> $3,681.59 BALANCE DUE-----------------------> $0.00 ......,.......................x....._........................,...............x.,..=,,,,,...»......,..............._,..,......«..............a...x...........�....................,........ DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the town's zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR I�PE�'f'ION Sh�Pc BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM-4:OO,FM. ,-�" a'4,,' '-'� -C/' iC'� '13 �� gna ure of Owner or Con ctor Date �l�rZ[-�C HE.�(_.c'� Print Name T combination permit_012811 � . � �w�aFV�, . ..................................................................................................................................................................................... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 611-0374 Address: 1230 WESTHAVEN CIR VAIL Owner: BRADSHAW, DAVID C Location: UNIT B ........................................................�..,,.,.............,......,......,,..,,.,..,...............,.,,...,................,........,..........,.....,,....,,........ Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 combination permit_012811 . � � 1 V T1t! V� T� , *�***«****«***«*«********«************�******«****,,,,««**«*******„**«***.*�*******«**.«***«**«*«*«*****«*.**********************«******««**«*«*«***.,** REQUIRED INSPECTIONS AND STATUSES Permit#: 611-0374 Address: 1230 WESTHAVEN CIR VAIL Owner: BRADSHAW, DAVID C Location: UNIT B *.,**«*.,**.,***.,*******************.,****************«*,.**********„*,.*****,,.,**,.*********w**�*,,,.*«******�****************«�***********«*****«*„****«***** Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00230 PLMB-Rough/Water Item: 00240 PLMB-Gas Piping Item: 00030 BLDG-Framing Item: 00290 PLMB-Final Item: 00190 ELEC-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 ' � � 11-14-2011 Inspection Request Reporting Page 12 4:16 t�m Vail, O - itv Of �Q�`�022� r Requested Inspect Date: Tuesday, November 15, 2011 ? Site Address: 1230 WESTHAVEN CIR VAIL UNIT B A/P/D Information Activity: 611-0374 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occupancy: Use: R-3 Insp Area: Owner: BRADSHAW, DAVID C Contractor: �NVCANS CHAFFEE CONSTRUCTION GROUP Phone: 970-845-0466 Description: REMODEL OF EXISTING WOOD DECK AND REPLACEMENT WITH NEW STONE/PAVED TERRACE WINDOW UNIT AT KITCH�NIREPLACE AND FREE-STANDING SPA UNIT. REPLACEMENT OF EXISTING Reauested Inspection(s) Item: 90 BLDG-Final Requested Time: 09:30 AM Requestor: NE�ANS CHAFFEE CONSTRUCTION GROUP Phone: 970-845-0466 Comments: 418-3390 Assigned To: ON Entered By: JMONDRAGON K Action: Time Exp: Item: 190 ELEC-Final Requested Time: 08:30 AM Requestor: N�ANS CHAFFEE CONSTRUCTION GROUP Phone: 970-845-0466 Comments: 418-3390 Assigned To: JM Entered By: JMONDRAGON K Action: Time Exp: Item: 290 PLMB-Final Requested Time: 09:00 AM Requestor: N�ANS CHAFFEE CONSTRUCTION GROUP Phone: 970-845-0466 Comments: 418-3 90 Assigned To: J Entered By: JMONDRAGON K ; Action: Time Exp: Y;, Item: 390 MECH-Final Requested Time: 08:00 AM Requestor: N�ANS CHAFFEE CONSTRUCTION GROUP Phone: 970-845-0466 Comments: 418-3390 Assigned To: J t? N Entered By: JMONDRAGON K Action: Time Exp: l � ( � Inspection Historv Item: 120 ELEC-Rough Item: 200 MECH-Rough "*Approved"* 11/01/11 Inspector: JRM Action: AP APPROVED Comment: SNOW MELT 100#AIR TEST Item: 230 PLMB-Rough/Water "*Approved"" 11/01/1T Inspector: JRM Action: APAPPROVED Comment: Item: 240 PLMB-Gas Piping •"Approved'* REPT131 Run Id: 13776 � TOWN OF UAII COM DEU 75 S FROi NE RD. UAIL, N 81657 970-479 - 2324 TERMINAL I.D.; 2002 MERCHANT N; MASTERCARD ��itik�ki�1�k88381 SALE BATCH: 080350 I NU : 000010 AUTH:45906P OCT 07: 11 12:13 TOTAL $3177.81 CUSTOMER COPY TOWN OF VAIL, COLORADO Statement Statement Number: R110001425 Amount: $3,177.81 10/07/201101:17 PM Payment Method:Credit Crd Init: DR Notation: MC DAVID C. BRADSHAW ----------------------------------------------------------------------------- Permit No: Bll -0374 Type: COMBINATION BLDG PERMIT Parcel No: 2103 -121- 0701 -5 Site Address: 1230 WESTHAVEN CIR VAIL Location: UNIT B Total Fees: $3,681.59 This Payment: $3,177.81 Total ALL Pmts: $3,681.59 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description -------------- Current Pmts - - - - -- ------------------------ - - - - -- BP 00100003111100 BUILDING PERMIT FEES ------ - - - - -- 874.75 EP 00100003111100 ELECTRICAL PERMIT FEES 230.00 MP 00100003111100 MECHANICAL PERMIT FEES 300.00 PF 00100003112300 PLAN CHECK FEES 293.06 PP 00100003111100 PLUMBING PERMIT FEES 15.00 UT 11000003106000 USE TAX 4% 1,450.00 WC 00100003112800 WILL CALL INSPECTION FEE 15.00 TOWN OF UAII COM DEU 75 S FROi NE RD. UAIL, N 81657 970-479 - 2324 TERMINAL I.D.; 2002 MERCHANT N; MASTERCARD ��itik�ki�1�k88381 SALE BATCH: 080350 I NU : 000010 AUTH:45906P OCT 07: 11 12:13 TOTAL $3177.81 CUSTOMER COPY f ((� TOWN OF VAIL Department of Community Development, 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: z3 s WeFM (Number) (Street) pp (Suite #) Building /Complex Name: ha Contractor Information Business Name: Business Address: IeO /§n,( 2 6 C City �S C Zip: Contact Name: Vleom / t/ oly. Oh Contact Phone: _ / X • 4 76 • 2W/ Contact E -Mail: 4P a S �� 9Nha ��'I S • GB A& A ro X Owner /Owner's presentative gignature (Required) Applicant Information Applicant Name: /Ye. Applicant Phone: J / 7 /7 - 191 • � 711 Applicant E -Mail: 4 hr"c 2ov 6 mp. w. o-m Project Information Electrical Square Footage Owner Name: P ?�( * w � "a Parcel #: Z/0 3 / P7 P S (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us/patie) Project #: 1f — oLA q ` DRB #: M LIP �P Building Permit #: 4 1—aDL / / Lot #: � Block # Subdivision: A !� lt p Work Class: New ( ) Addition ( ) Alteration (X) Type of Building: Single - Family ( ) Duplex A) Multi - Family ( ) Commercial ( ) Other( Work Type: Interior ( ) Exterior( ) Both X Valuation of Work Included Plans Included Work Electrical (x)Yes ( )No ( )Yes (x)No Mechanical (x)Yes ( )No ( )Yes (�No I�J�i`JflO Plumbing N)Yes ( )QNo ( )Yes (X)No IMF Building (XYes ( )No (Yes ( )No DO Value of all work being performed: $ 7 7� (value based on IBC Section 109.3 & IRC Section 108.3) Gc P. foR. Detailed Scope and Location of Work: c°me / ' e 0 e S `1 ;VPs itl- w s hoelp rp -o-iii a a holkLiw v4 �aa_e -sfaa itio s ba G�tii�' _ 1Z /aUe/ti,Qu � �X s /nQ w'tti�o w tiN� a�` (use additional sheet if necessary) For Office Use Only: Fee Paid: 4553 78 Received From: Suowoepi AN oPK1�S Cash Check # / °/y CC: Visa / MC Last 4 CC # exp date: Auth # Date Received: TOWN OF VAIL SEP 1 2011 W C mpLeTG - rNis ZOfE ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R110001336 Amount: $503.78 09/27/201103:28 PM Payment Method: Check Init: SAB Notation: 1014 - SNOWDON & HOPKINS ----------------------------------------------------------------------------- Permit No: Bll -0374 Type: COMBINATION BLDG PERMIT Parcel No: 2103 - 121 - 0701 -5 Site Address: 1230 WESTHAVEN CIR VAIL Location: UNIT B Total Fees: $3,641.29 This Payment: $503.78 Total ALL Pmts: $503.78 Balance: $3,137.51 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 503.78 Bradshaw OPTIONAL LOAD CALC. PER NEC 220 -80 DESCRIPTION OF LOAD QUAN LOAD (VA) TOTAL LOAD (VA) LIGHTING AND RECEPT. (3,720 SQ.FT. X 3VA) 2800 3 8400 SMALL APPLIANCE CIRCUIT 2 1500 3000 LAUNDRY CIRCUIT 1 1500 1500 RANGE HOOD 1 1500 1500 DISPOSAL 1 1200 1200 REFRIGERATOR 2 950 1900 TRASH COMPACTOR 950 0 FREEZER 950 0 DISHWASHER 1 950 950 RANGE 1 8000 8000 STEAMER 9600 0 CIRCULATION PUMP 460 0 HUMIDIFIER 0 HOT TUB 1 9600 9600 WHIRLPOOL TUB WO/ HEATER 1500 0 BOILERS / GAS FURNACE 3 1800 5400 FAN COIL 0 AC CONDENSOR 0 POND AIRRATOR 0 DRYER 1 5000 5000 1800 0 GARAGE DOOR 1 800 800 TOTAL 47250 MOTORS: PUMPS 3 450 1350 HEATING /COOLING (LARGEST LOAD @ 100 %) 0 TOTAL @ 100% 1350 LARGEST 100% OF 10kVA 10000 40% OF REAMAINDER 14900 100 % of line 32 1350 1350 TOTAL CALCULATED LOAD: 27600 25% FUTURE FACTOR 6900 TOTAL KW 34500 VOLTAGE SINGLE PHASE: TOTAL CALCULATED VA /240V= 143.75 AMPS f U i riang e i r:::::: Engineering Submittal S010 250 L Engineering Submittal Dala • ASIME Boiler Certification - ASME "II' Stamp • ENERGY STAR Qualified • Unit complies with ANSI Z21.13 and CSA 4.9 Boiler Standards • Fully condensing — 95 AFUE efficiency • Full modulation capability from 1 5% to rated input • Modulation allows fewer and longer cycles leading to lower operating cost and longer component life • Low pressure drop heat exchanger • Control interface and logic for indirect hot water storage tank with priority • .Approved for zero clearance to combustibles (excluding vent and boiler piping) • Automatic boiler freeze protection • Anti- freeze allowed when used per manufacturer's speci- fications. • Superior grade stainless steel heat exchanger construction - 439 Grade • Self cleaning flue ways in heat exchanger • Low NOx operation exceeding SCAQ \SID 2012 regulations Project / Location: — _ Date: Consulting Engineer / Architect: Mechanical Contractor: Notes: • Digital display control panel • Use of 3" PVC, CPVC or AL29 -4C pipe for vent and air up to 30 equivalent feet each or 4 "up to (10 equivalent feet each (total length and fittings — each 90° elbow equals 5 feet and each 45 0 elbow equals 3 feet) • Limited 10 year warranty • Boost feature for low temperature startup • Light weight construction for wall mounting g g g • Standard equipment: ;� AS. 1L _) sl pressure p p re relief valve pressure and temperature gauge high limit temperature safety control outdoor temperature reset control - air vent 24 volt terminal strip with removable jumpers for manual reset or automatic reset automatic low water cutoff feature variable speed blower • !Microprocessor electronic gas and air controller • Stainless steel premix burner • Reliable spark ignition • Unique geometry — 3 consecutive baffles guide water now through the heat exchanger and around the combus- tion chamber • Nigh water content — stable temperature control and less sensitive to water flow • Electronic controls with easy to read menus, performance and trouble shooting codes • Swing out control panel for easy access and servicing • Attractive appliance design for installation in high visi- bility areas. • Boiler water supply temperature can be maintained by the Prestige, eliminating the need for a mix system to achieve the desired temperature with high limit protection Date 015109 20'4 -2 Prestige Submittal 257 . ::.<'> :. •.x , >< "{ •:<:: .... . ... . ...................... . :....:::: 4< s»» :.. .................... t:;, 4W} �.•.! t, L:•, i;`' M1.:+ r;;';•: h'':::>:: i::;:>: ii:=;: �; i;:�i:�i;::�::�::�::�i::;:::::: `/d -fQ6 f� Engineering Submittal Dala • ASIME Boiler Certification - ASME "II' Stamp • ENERGY STAR Qualified • Unit complies with ANSI Z21.13 and CSA 4.9 Boiler Standards • Fully condensing — 95 AFUE efficiency • Full modulation capability from 1 5% to rated input • Modulation allows fewer and longer cycles leading to lower operating cost and longer component life • Low pressure drop heat exchanger • Control interface and logic for indirect hot water storage tank with priority • .Approved for zero clearance to combustibles (excluding vent and boiler piping) • Automatic boiler freeze protection • Anti- freeze allowed when used per manufacturer's speci- fications. • Superior grade stainless steel heat exchanger construction - 439 Grade • Self cleaning flue ways in heat exchanger • Low NOx operation exceeding SCAQ \SID 2012 regulations Project / Location: — _ Date: Consulting Engineer / Architect: Mechanical Contractor: Notes: • Digital display control panel • Use of 3" PVC, CPVC or AL29 -4C pipe for vent and air up to 30 equivalent feet each or 4 "up to (10 equivalent feet each (total length and fittings — each 90° elbow equals 5 feet and each 45 0 elbow equals 3 feet) • Limited 10 year warranty • Boost feature for low temperature startup • Light weight construction for wall mounting g g g • Standard equipment: ;� AS. 1L _) sl pressure p p re relief valve pressure and temperature gauge high limit temperature safety control outdoor temperature reset control - air vent 24 volt terminal strip with removable jumpers for manual reset or automatic reset automatic low water cutoff feature variable speed blower • !Microprocessor electronic gas and air controller • Stainless steel premix burner • Reliable spark ignition • Unique geometry — 3 consecutive baffles guide water now through the heat exchanger and around the combus- tion chamber • Nigh water content — stable temperature control and less sensitive to water flow • Electronic controls with easy to read menus, performance and trouble shooting codes • Swing out control panel for easy access and servicing • Attractive appliance design for installation in high visi- bility areas. • Boiler water supply temperature can be maintained by the Prestige, eliminating the need for a mix system to achieve the desired temperature with high limit protection Date 015109 20'4 -2 Prestige Submittal 257 uIml ................... 7/4 NP9C Pressure Relief Valve S' Vent OfIllel 3".Combumion Alt m4l 314' WT " Connftllqn 1-1w P - 4 N" Belief Return ............ — 4 114' NPT Sailer Supply Front View :114' NPT Oft Com*elka /4' N,PT.BWW Raturn .IV MPT Boller Supply mkwk-f FUCI Infilsf ; A FIJ 1 001. N F I' Wattr %lPp�,-iRzt-lrjj (i.15 W' WAir 'W'ciallt 6,9 13.5 16.5 14.9 22.5 25.8 modulation K�afiog I- Volume cOlkilectiorm C - ('"ecticrl Divat2tmr 1.11's 11F3I1 ^; capold" NI BI I (W. N Natthful Stilt) 250 Yrttl +anc !fj 243 1 : 41- - ) - )3 ]')4 J _, .4 142 Pressure Drop Curve with Grundfos Circulators 3 2. 0 d 23.0 � 24.0 , 0.0 CL - 16.0 0 E! 12.0 5 8 10 13 15 19 26 Flow Rate (GPM) 71 4 Wsc Pressure Ram volvt , Comk"jolion Air Inlet Prestige SOLO 250 Grundfos UP26-99F Grundfos UP26-64F 6 ... Grundfos UPS16-58F/FC - Spd 3 25 Delta T GPM Available 'ystem Head in Feet UP,915-58F/FG UP26-641- U1 20 30 40 19.4 12.9 9.7 --- 4,5 8.8 6,9 13.5 16.5 14.9 22.5 25.8 Note: Ivlinimum allowable flow rate at full input: 12 gpm Solo 250 2 Side View Prestige Gas Vent Stainless fX» Sidewall Termination Kit Thangl6 Kit Part Number: IRAIAMII III I 3 Inch Vent Sidewall Termination PSVKIT02 4 Inch Vent Sidewall Termination Recommended tools: • Phillips Screwdriver • Core Drill or Hole Saw ® Indicates a potentially hazardous situation which, if ignored, can result in serious injury or substantial property damage. - - ---- I A WARNING''; Failure to follow instructions below can result in severe personal injury or damage if ignored. • Instructions are for a qualified installer/ser- vice technician. • Read all instructions before proceeding. • Follow instructions in proper order. NOTICE Indicates special instructions on installa- tion, operation or maintenance, which are important to equipment but not related to personal injury hazards. 1 EXTROV Expansion Tanks In-Line Models A E ma FXTROL" FILL-JROLc Job Name Location Engineer Specifications and Dimensions Model i Tank No. i Vol ume Acceptance Volume - Liters A B Nei ht Diameter System Conn.' Ship wt. Liters Gallons Gallons mm inches mm inches inches kg lbs. 15 1 8 --- - ----------------------------- 30 1 17 2.0 ----------------------- 4.4 3.4 0.9 --------------- 9.5 2.5 321 1 1 2Ve 1 203 -------------------------- - - --------- I ---- 381 1 15 279 8 ---------- - --- 11 1 12 ---- ---- ---- yz 2.3 -- - ---------- 4.0 5 ------------ 9 60 1 : 33 7.6 9.5 i 2.5 1 584 i 23 279 11 1 /2 7.0 14 90 1 53 ------- ! ---------------------------------- 14.0 42.0 1 - ---------- --L--! 533 1 21 390 ---------------------- ---- 15 3 /8 1 2 10.0 23 Specifications and Dimensions Model Tank Acceptance A B System Ship No. Volume Volume Heiaht i Diameter Conn. Wt, Liters Gallons Liters Gallons mm i inches mm inches inches kg lbs. 109 8 2.0 3.4 0.9 375 143 a 203 8 ' 2.7 6 110 17 4.4 9.5 2.5 441 17 3 /8 279 11 1 '2 4.5 10 111 33 7.6 9.5 i 2.5 625 244 279 11 1 /2 6.8 15 112 53 14.0 ------------- - - --------------- 42.0 1 11.3 --------------- -------------- ------------- 584 '1 23 i 390 --------------- 15 ------- - ----- V2 ------------- 10.8 --- - - - -- 24 Maximum Operating 240 °F (115 °C) Conditions ..... . Operating Temperature ............ . .... 1 ] Working Pressure 100 PSIG (7 bar) --- - ------ - -- - ------------------------------------- I ----------------------------------------------------------- --- - -------- All dimensions and weights are approximate. Contractor Contractor P.O. No. Sales Representative Model No. Ordered Rev. 03/10 Submittal data sheets can ONLY be ordered as a "Submittal Data Sheet Pack", using MC# 4400. They are not available to order on an 26 P/N 4400-026 individual basis, however each data sheet is available on the AMTROL Web Site and can be downloaded and printed for use as needed. For the most updated technical specifications, please download sheet at www.amtrol.com ® Submittal Data VJS -1 B Spirovent @ Junior Microbubble "'M Eliminator (with Sweat Connections) Job Name: Engineer: Contractor: Representative Tag Model Flow I Size Location Specifications: Shell Brass Vent Head Brass Float Non - Ferrous Seal Viton O Rincl Viton Coalescinq Medium Copper Max. Working Pressure 150 psiq Max. Operating Temperature 270 °F Notes: T (Pipe Size) 3 /4 " 1" 1 -1/4" D inches 2.6 2.6 2.6 H1 inches 6.0 7.0 7.8 h1 inches 0.8 1.4 1.5 L inches 4.1 4.5 4.5 e inches ' /1 �/2 1 /2 Weight 3.0 3.2 3.5 Rec. Flow m 6 10 15 Model No. VJS- 075TM 100TM 125TM (dimensions for reference only) © 2008 Spirotherm, Inc., 25 North Brandon Drive, Glendale Heights, IL 60139 Technical data "'t Super Brute H UP Series UPS 15- 58FC /FRC Flow range: 0 -17 U.S. gpm Head range: 0 -19.5 feet Motors: 2 -pole, single -phase Max. liquid temperature: 230 T (110 °C) Min. liquid temperature: 36 T (2 °C) Max. system pressure: 145 psi Model Spd Volts Amps Watts Hp Capacitor 3 0.75 87 1/25 10µF /180 V UPS 15- 58FC /FRC 2 115 0.66 80 1/25 10µF /180 V 1 0.55 60 1/25 10µF /180 V Without check valve With check valve Position r- 3 of 0 � 2 � 1 16 18 20 0 0 [US GPM] UPS 15 -58FC UPS 15 -58FRC B B C C r, LL1 N W n p _ aD �- F � Model type Product number UPS 15 -58FC 59896341 UPS 15 -58FRC 59896343 Note: The check valve can be removed. A B C D E F 61/2 5 1/4 4 43/16 3 35/32 6 112 5 1/4 4 4 3/16 3 35/32 System type Description Closed High speed Closed Medium speed Closed Low speed Connection type Shipping weight and size [lbs] GF 15/26 flange (2) 1/2" dia. bolt boles 7 1/4 GF 15/26 flange (2) 1/2" dia. bolt boles 7 1/4 GRU- OFOS - N 47 4 b e 10 12 14 Figure 470 & 475 BRASS BODY BALL VALVES FNW� 2 PC FULL PORT 400 WOG PUMP ISOLATION VALVE Features: • 400 WOG • Full Port • Flanged Pump Connection • by NPT End (Fig. 470) ° by Sweat End (Fig. 475) • Integral Flange (no added parts) • Blow Out Proof Stem • Adjustable Packing • Forged Brass Body & End Cap • Includes T- handle, Gasket, and Hardware 400 rn 300 a 200 Q. 100 0 50 100 150 200 250 300 350 400 Temperature (F) Weiqhts Fig. 470 - FNPT Fig. 475 - Sweat Includes T- handle, Gasket, and Hardware The FNW 470 (NPT connection) and 475 (Sweat end connection) pump isolation valve decreases installation time and the number of possible leak paths by its integral pump flange connection. Pump isolation valves make pump servicing easier by isolating the pump and providing ease of disconnect for pump removal. Size Wt. (Lbs) Fig 470 Fig 475 3/4 1.72 1.71 1 1.82 1.77 1 -1 /4 2.08 2.08 1 -112 2.60 2.66 Figure Number Matrix FNW END X END TYPE SIZE CODES 0 = NPT ENDS 3/4 = F 1 -1/4 = H 5= SWEAT ENDS 1= G 1 -1/2 = J For other valve materials or configurations, contact FNW Valve at (503) 287 -8383 for sales assistance. 4120 NE Columbia Blvd. - Portland, Oregon USA 97211 Phone: 503- 287 -8383 - Fax: 503 - 281 -9677 - www.fnwvalve.com 1% Figure 470 & 475 BRASS BODY BALL VALVES 2 PC FULL PORT 400 WOG PUMP ISOLATION VALVE E - 6 8 F--- 9 13 11 I i 11 7 ' 2 THREADED SWEAT H 0G i � 1 R fi I I 0D2 OD- - - -T- - - - 0D2 I I 3 ON I 1 I s 4 3 T2 L2 L3 L -L O B 0 117 0 374 0.512 T- Handle - - -- -- 0 787 0 433 4.000 Dimensions finches) Size OB OD OD2 Threaded Dimensions E OG H L L1 L2 L3 ON R T2 470 475 3/4 3.150 0.748 0.878 3/4" - 14 NPT 4.331 2.756 12.3822.421 Stem Packing 12.61811.220 1 0.75 1.22 0.492 0.453 0.394 1 3.150 0.984 1.126 1" - 11 -1/2 NPT 4.331 2.756 2.559 2.815 13.07111.378 0.87 1.38 0.492 0.453 0.394 1 -1/4 3.150 1.142 1.378 1 -1/4" - 11 -1/2 NPT 4.331 2.756 2.717 3.090 3.543 1.535 1.10 1.54 0.492 0.453 0.394 Ti/213.15011.457 1.628 1 -112" - 11 -112 NPT 4.331 2.756 2.913 3.465 3.917 1.732 1.10 1.73 0.492 0.453 0.394 Standard Materials Ref. No. Description Material Qty 1 Body Brass - C37700 1 2 all Brass - C37700 1 3 End Cap Brass - C37700 1 4 Seat PTFE 2 6 Stem Brass - C36000 1 7 Stem Packing PTFE 1 8 Handle Steel - AISI -1010 1 9 Handle Cover Plastic 1 Ref. No. Description Material Qty Remarks 11 Gland Nut Brass - C36000 1 12 Handle Washer ASTM G1566 1 13 Handle Nut Steel - AISI -1010 1 14 Flange Bolt Steel - AISI -1010 2 Not shown 15 Flange Nut Steel - AISI -1010 2 Not shown 16 Flange Gasket Rubber - NBR 1 Nohown t s 17 T- Handle Steel - AISI -1010 1 DOC: FNWBVP107 Ver. 5/07 © 2007 - FNW. All rights reserved. The FNW logo is a registered trademark of Ferguson Enterprises, Inc. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Always verify that you have the most recent product specifications or other documentation prior to the installation of these products. Technical data Flow range: Head range: Motors: Max. liquid temperature Min. liquid temperature: Max. system pressure: Super Brute H [ft 2E 2� 2( tE 12 8 4 0 1 UP Series UPS 26- 99FC /BFC 0 -33 U.S. gpm 0 -29 feet 2 -pole, single -phase 230 T (110 °C) 36 T (2 °C) 145 psi Model Spd Volts Amps Watts Hp Capacitor 3 1.8 197 1/6 20µF/180 V UPS 26 -99FC 2 115 1.5 179 1/6 20µF/180 V 1 1.3 150 1/6 20µF /180 V 3 0.9 196 1/6 5µF /400 V UPS 26- 99FC /BFC 2 230 0.8 179 1/6 5µF /400 V 1 0.7 150 1/6 5µF /400 V Without check valve co N _ _ With check valve N M Position S 0 4 8 12 16 20 24 28 32 36 ystem type Description Q [US GPM] ~ 3 open (BF )) and High speed 2 Closed (FC) and j open (BFC Medium speed 1 Closed (FC) and open (BFC Low speed UPS 26 -99FC UPS 26 -99BFC B B C C Q _ CO is - - W i g W I o o w -� —_ F- 0 0 F Model type Product number i Connecton type Shipping A B C D E F YP Aping weight 115 V 230 V and size fibs] UPS 26 -99BFC 52722518 52722519 6 112 6 4 7/8 3 112 37/16 35/32 GF 15/26 flange (2) 1/2" dia. bolt boles 10.3 UPS 26- 99FC /BFC 52722512 52722513 6 1/2 6 47/8 3 1/2 37116 35/32 GF 15/26 flange (2) 112" dia" bolt boles 10.3 Note: The check valve can be removed. 54 GRUNOFOS' I/ rr Figure 470 & 475 BRASS BODY BALL VALVES FNW � ' 2 PC FULL PORT 400 WOG PUMP ISOLATION VALVE Features: • 400 WOG • Full Port • Flanged Pump Connection • by NPT End (Fig. 470) ° by Sweat End (Fig. 475) • Integral Flange (no added parts) • Blow Out Proof Stem • Adjustable Packing • Forged Brass Body & End Cap • Includes T- handle, Gasket, and Hardware `''` •> .a :.r. 400 c� V) 300 a 200 a` 100 0 50 100 150 200 250 300 350 400 Temperature (F) Weiqhts Fig. 470 - FNPT Fig. 475 - Sweat Includes T- handle, Gasket, and Hardware The FNW 470 (NPT connection) and 475 (Sweat end connection) pump isolation valve decreases installation time and the number of possible leak paths by its integral pump flange connection. Pump isolation valves make pump servicing easier by isolating the pump and providing ease of disconnect for pump removal. Size Wt. (Lbs) Fig 470 Fig 475 3/4 1.72 1.71 1 1.82 1.77 1 - 114 2.08 2.08 1 -1/2 2.60 2.66 Figure Number Matrix FNW47 END = END TYPE SIZE CODES 0 = NPT ENDS 3/4 = F 1 -1/4 = H 5= SWEAT ENDS 1= G 1 -1/2 = J For other valve materials or configurations, contact FNW Valve at (503) 287 -8383 for sales assistance. 4120 NE Columbia Blvd. - Portland, Oregon USA 97211 Phone: 503- 287 -8383 - Fax: 503 - 281 -9677 - www.fnwvalve.com FNW"" Figure 470 & 475 BRASS BODY BALL VALVES 2 PC FULL PORT 400 WOG PUMP ISOLATION VALVE 6 8 13 ' 12 11 7 2 THREADED SWEAT H OG t R ' I I OD2 OD - - T - - - OD2 I I ON 1 I T2 L3 4 3 L2 L -L O B 0 217 fO 374 0.512 T- Handle - - -- -- 0.787 0.4 4.000 T Dimensions (Inches) Size OB OD OD2 Threaded Dimensions E OG H L L1 L2 L3 ON R T2 470 475 3/4 3.150 0.748 0.878 3/4" - 14 NPT 4.331 2.756 12.382 2.421 r2.618F1.220 1 0.75 1.22 0.492 0.453 0.394 1 3.150 0.984 1.126 1" - 11 -112 NPT 4.331 2.756 2.559 2.815 13.071 11.378 0.87 1.38 0.492 0.453 0.394 1 -1/4 3.150 1.142 1.378 1 -1/4" - 11 -112 NPT 4.331 2.756 2.717 3.090 13.543 11.535 1.10 1.54 0.492 0.453 0.394 1 -1/2 3.150 1.457 1.628 1 -112" - 11 -112 NPT 4.331 2.756 2.913 3.465 13.917 11.73211.10 11.73 0.492 0.453 0.394 Standard Materials Ref. No. Description Material Qty 1 Body Brass - C37700 1 2 Ball Brass - C37700 1 3 End Ca Brass - C37700 1 4 Seat PTFE 2 6 Stem Brass - C36000 1 7 Stem Packing PTFE 1 8 lHandle Not shown Steel - AISI -1010 1 9 1 Handle Cover Plastic 1 Ref. e Description Material Qty Remarks 11 Gland Nut Brass - C36000 1 12 Handle Washer ASTM G1566 1 13 Handle Nut Steel - AISI -1010 1 14 Flange Bolt Steel - AISI -1010 2 Not shown 15 Flange Nut Steel - AISI -1010 2 Not shown 16 Flan e Gasket Rubber - NBR 1 Not shown 17 IT-Handle I Steel - AISI -1010 1 DOC: FNWBVP107 Ver. 5/07 © 2007 - FNW. AN rights reserved. The FNW logo is a registered trademark of Ferguson Enterprises, Inc. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice, Aways verify that you have the most recent product specifications or other documentation prior to the installation of these products. Certilicate 848007 The Dow Chemical Company Date: 01/23/2002 Certificate 01 Analysis OCTAGON PROCESS INC OCTAGON PROCESS INC 7 350.!(ARMERIA DR COMMERCE CITY CO 80022 -0000 Gust P.O.: 4500158467(10170729) Materin e PROPYLENE CLYCOL INDUSTRIAL Cust Mt':: 1517 -004/1 vi'hicle: PLCX224786 Ship from: THE DOW CHEMICAI. COMPANY Page 1 Fax: 2019459448 UNITED STATES Dlvy Noie: 67081646 10 Spec: 00070511 -9 PLAQUEMINE LA UNITED STATE5 This material meets the requirements of the specification. The Features listed below the double spaced line ar•e monthly composites. Feature Units Results QA2301A508 Limits Minimum - --------------------------------------- kaxirnurn Method Assay calc'alated 'E wt 99.96 99.00 - ---------- ---- DOWM •------ - - - - -- 100687 Acidity 1G "wt 0.0001 AS Acetic Acid -- 0,0020 DOtdM 101370 Appearance Passes clearimatter free Visual Chlorides ppin 0.0 Color, Pt "Co 2 "" 1.0 DOWM 101867 iron ppill 0.000 "- " 10 ASTM 05386 water Content wt 0.010 - -- 0.500 - ASTM E202 - -- 0.200 ASTM F203 iYpiC21 Properties The values listed are considered physical properties and are not analyzed on a routine basis, SP-GI @ 20;200 1.0375- 1.0390 SP.Gray. @ 25/250 1, 0352 - 1.0365 This product i5 not intended for use in pharmaceutical, foo Cq£mHtic type applications. d or Nonnie W. Ulbright, Analytical Technologist PO /EO & Gerivatives For inquiries please contact Customer Service or local sales. Enriiish: 800 -232 -2436 French: 600 -565 -1255 BASIC PRODUCT DESCRIMONS: PGI AND PGI -HD HEAT TRANSFER FLUIDS PG1 fluid is a formulation of 95.5 % propylene glycol, dipotassium phosphate and water. The fluid �Ir colorless (white water). PG1 fluid has an operating temperature range of -50 F to 250 F. and solutions in water provide freeze protection to below -60 F and burst protection to below -100 F. PGI -HD fluid is a formulation of 94.0 percent propylene glycol and a specially designed industrial package of corrosion inhibitors. The fluid is dyed bright yellow to aid in leak detection. PGI -HD fluid has an operating temperature range of -50 F to 350 F and solutions in water provide freeze protection to below -60F and burst protection to below -100 F. Both fluids are practically odorless and are low in acute oral toxicity. They offer good heat transfer characteristics, good freeze and corrosion protection, and low volatility. These fluids are hygroscopic at low temperatures, which means they attract moisture from the surrounding atmosphere. Both fluids are also non - flammable in solutions up to 80 percent glycol in water. Typical Product Physical Properties Composition (% by Weight) Propylene Glycol Inhibitors and Water Color Specific Gravity (at 60/60 F)' PE of Solution (50% glycol) PG1 PGI -HD 95.5 94.0 4.5 60 Water White/O -c dyE 6 bkuc Bright Yellow 1.050 1.060 1.053 - 1.063 9.0- 10.0 9.5 -10.5 4 PREPARING SYSTEMS FOR THE ADDITION OF PGI OR PGI -HD EXHISTING SYSTEMS In existing systems, all lines and materials should be cleaned and flushed thoroughly before charging the system with PG1 fluid. This is espVcially important if fluid previously in the system is incompatible with the new inhibited glycol fluid. If a fluid containing silicates (such as automotive antifreeze) was previously used; it may be necessary to-clean silicate residues from the system. It is also important to remove all rust, scale and sediment in the system. Traces of chloride should be removed, whether from old fluid or residue from acid cleaner, because chlorides can contribute to corrosion. For heavily fouled or corroded systems, an optimum cleaning procedure includes the use of an inhibited acid followed by neutralization and phosphatization. If chemical cleaning is used, it is important that all traces of the cleaning agent be removed, and the system be tboroughly flushed with water. NEW SYSTEMS New systems are typically coated with oil, grease or a protective film during fabrication, storage or construction. Dirt, solder flux, and welding and pipe scale can also cause problems. Therefore, thorough cleaning of new systems is recommended. A solution of 1 to 2 percent trisodium phosphate can be used with water for flushing the system. System volume can be calculated during this stage by metering in the initial fill of the system, or chemical analysis of cleaning chemicals after known quantities are introduced into the system. ( ow MATERIAL SAFETY DATA SHEET INHIBITED PROPYLENE GLYCOL SECTION 1 IDENTIFICATION COMPANY NAME: CHEMICAL SPECIALTIES, INC. EMERGENCY PHONE NUMBER: 303 - 675 -0944 TRADE NAME: INHIBITED PROPYLENE GLYCOL SECTION 2 HAZARDOUS INGREDIENTS Chemical Name/ Common Name Cas# Percentage TLV Source Propylene glycol 000057 -55 -6 95% N/A Dipotassium Phosphate 007758 -114 <3% N/A Deionized Water 007732 -18 -5 <3% N/A This document is prepared pursuant to the OSHA Hazard Communication Standard (29CFR 19101200). In addition, other substances not "Hazardous" per this OSHA Standard may be listed. Where proprietary ingredient shows, the identity may be made available as provided in this standard. NFPA RATINGS (Scale 0 -4) Health Fire Reactivity Other 0 1 0 N/A SECTION 3 PHYSICAL DATA BOILING POINT: 370F, 188C SPECIFIC GRAVITY:(H2O =1) N/C VAPOR PRESSURE (mm Hg):.22 mmHg @20C ph: 9.5 -10 VAPOR DENSITY (Air 2.62 EVAPORATION RATE: unknown SOLUBILITY IN WATER: COMPLETE APPEARANCE /ODOR: clear SECTION 4 FIRE AND EXPLOSIN HAZARD DATA FLASH POINT: 215F, 102C EXTINGUISH MEDIA: NONE NEEDED SPECIAL FIRE FIGHTING PROCEDURES: NONE UNUSUAL FIRE AND EXPLOSION HAZARDS: N/A SECTION 5 REACTIVITY DATA CHEMICAL STABILITY: Stable in normal temp range (- 30F -250F) INCOMPATIBLE MATERIALS: Unknown DECOMPOSITION PRODUCTS: N/A CONDITIONS TO AVOID: NONE HAZARDOUS POLYMERIZATION: Will not occur. Job Designer Contact Snow Melting C 665 01/11 Replaces: New The Snow Detector & Melting Control 665 is designed to operate mechanical equipment to melt snow off an outdoor slab. It can be used in hydronic or electric snow melting applications. This product uses a tekmar snow /ice detection sensor in order to automatically melt snow using Pulse Width Modulation (PWM) and slab Outdoor Reset to maintain slab temperature. It is capable of controlling a single boiler, a system pump, and providing a signal when melting is enabled. Front View Side View Mounting Base 1!2" (13 mm) . •.{ f :y ; }:y t Y•" �Y \Y:�:Y:i }i } }}•t \`. : � Q ,fv'Fi {•' : 7 18" 0 .va.. —1 ♦ r " ?:': .fir pa + s "Y . °• <::: > +£r.. �. :. �t ` * .r4:.y d ,,.)�:: .:^.a... x.x. ;:;:f;Y:ti:;: ;C YYk� {� '•:4k$2:'1r. ' +, . } '}` 'y' .¢;... ) twee ar' t(tl ii:m Snw IW�cY.•L Ongel••s Vi b:•�•::• }:• }:4: ^' '�}+ .; L. . YY• . • �V V.a g ............ •r {:i ?i:4: �• } +:::Y::h:w'..: _v.y } �.,t {,., . ; v �. .': }'Yy ; \q y:K + + ti{Y? }::v: ���� v: J.v •. v: �'- 1�: iiiii 'i:{:i:Y�i'r ?iiiji }..: ?;,:. 'VbF::n�'�.i >.h v: r .i rU lit' ...... .: ....: }: •,�. ?. . },;;. . 14 m { 1 -718" (49 min) 2 -713" I-E— --->� / i/2 "Knock -o;.4 7 -518'' (72 mm) 6 3/16' (5 rnm; (x 5 back) ix 5 bottom) (193 mm) Specifications Snow Detector & Melting Control 665 Pulse Width Modulation Literature D665, A665, U665, D001, D070 Control Microprocessor control. This is not a safety (limit' control Packaged weight 3.1 lb. (1400 g) Dimensions 6 -5/8" H x 7- 9/16" W x 2- 13/16" D (170 x 193 x 72 mm) Enclosure Blue PVC plastic, NEMA type 1 Approvals CSA C US, meets class B: ICES & FCC Part 15 Ambient conditions Indoor use only, 32 to 122 °F (0 to 50 0 C), RH 590% Non- condensin Power supply 115 V (ac) =10 %. 50/60 Hz, 600 VA Relay capacity 230 V (ac) 5 A, 1/3 hp Demand 20 to 260 V (ac) 2 VA Sensors NTC thermistor, 10 kQ a 77 °F (25 °C ±0.2 °C) 13 =3892 — Included Outdoor Sensor 070 — Optional tekmar type #: 039, 040, 072, 073, 090, 091, 094 Warranty Limited 3 Year (See D665 for full warrant SPECIAL REQUIREMENTS 090 Snow /Ice Sensor or Slab Sensor. Featu ............................... • Slab Outdoor Reset • Automatic snow detection and melt control (with 090 Sensor) • Temporary Idle • Manual Override • Warm Weather Shut Down • Cold Weather Cut Out • Remote display and adjustment capabilities • Test sequence to ensure proper component operation • Equipment Exercising • CSA C US certified (approved to applicable UL standards) www.tekmarcontrols.com 1 of 2 0 2011 ttel mw' C665 - 01111 Below is a sample application drawing for this product. This application may include other tekrnar products that are required for installation. More sample applications can be found at www.tekniarcontrols.com. Sample Electrical diagram Legend B1 = Modulating Boiler (Enable only) P1 = System Pump S1 = Snow Melt Sensor S2 = Outdoor Sensor YByw �+ ','T 0. Melt Demand �t-- - Idle Demand F WWSD t Water Melling Moot 0000 Menu Item A V tekmar` Snow Detector & Melting Control 665 Pulse Width ModulaOon 1 2 7 8 Rad I Bk I al. I Y" l Brn 1.' I M2 S2 W la�.eDwnam Daannd 121 S1 B1 120 V (ac) L N ------------------------------------------------------------------------------------------------------- t ekmar' tekmar Control Systems Ltd.. Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road, C,ortroI Systeins Vernon, B.C. Canada V1 B 3K4, 250 -545 -7749, Fax 250 - 545 -0650 web Site: www.tekmarcontroIs.com Product des ;gn, software and literature are Copyright r 2011 by: 1111 specifications are subject to change Without no:!ce. 1`* 2of2 iekmar Control Systems Ltd. and tekmar Control Systems. Inc. Printed in Canada. 0665 - G1i1'.. �� Test O a an -•:d n; roe raa, ?rvc! Isssrq u :ca: F:n ivaimure boat Bass 9 J hold TO Neon la 3 —111 e 90D -03 Meek Gass B: Made in Canada by Cenedien ICES *a . Codh,d SY0. -111 FCC Pod IS Power Relays 115 V t 1(r'. 50160 H2 IUO VA 230 V (n) S A 1/3 hp Demand 20 la 260 V 1.)2 C Its Sgnal wrong must be raled.11 -1300 V. 9 ! 10 11 I 12 f 13 17 McTrldle I Heal � ` � I Malfng Sys Power 121 S1 B1 120 V (ac) L N ------------------------------------------------------------------------------------------------------- t ekmar' tekmar Control Systems Ltd.. Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road, C,ortroI Systeins Vernon, B.C. Canada V1 B 3K4, 250 -545 -7749, Fax 250 - 545 -0650 web Site: www.tekmarcontroIs.com Product des ;gn, software and literature are Copyright r 2011 by: 1111 specifications are subject to change Without no:!ce. 1`* 2of2 iekmar Control Systems Ltd. and tekmar Control Systems. Inc. Printed in Canada. 0665 - G1i1'.. �� Job Designer Contact C 090 ><` 01111 ................... Snag Melting Replaces: New The Snow /Ice Sensor 090 is an in ground sensor used with tekmar snow melting controls to automatically detect snow or ice on a driveway or walkway. The 090 has 65 ft (20 m) of wire. This product can be used in applications ranging from residential driveways to commercial building fronts such as emergency access entries. This sensor allows tekmar snow melting controls to automatically operate the snow /ice melt system only when snow or ice is present, while also providing temperature feedback to the control. Side View Top View t/a• mm) (W Specifications Snow / Ice Sensor 090, Literature D090 Packaged weight 4.4 lb (2000 ) Dimensions 1 -3/4" H x 3 -7/16 O.D. (45 x 87 O.D. mm) Sensor material Silicon brass Cable Material 65 ft. (20 m) 5 conductor stranded wire with p olyethylene jacket Approvals CSA C US Operating range -30 to 170 °F 04 to 77 °C) Included 4 #4 -40, 7/16" machined, stainless steel screws 4 #6 -32, 3/8" flathead, slotted, stainless steel screws Warranty Limited 3 Year (See D090 for full warranty) Energy Saving Features • Automatic snow /ice detection so melting systems only operate when needed Additional Features ................................. • Slab temperature reading • Long wire included so in field splicing is not necessary • Designed for long life in driveway and walkway installations • 65 ft (20 m) of cable SPECIAL REQUIREMENTS This sensor must be used with a tekmar Snow%Ice Melting Control 665, 667, or 664, and installed in a 091 socket. t&Mar &' tekmar Control Systems I_td., Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road, control systerns Vernon, B.C. Canada V18 3K4,250-545-7749, Fax. 250 -545 -0650 Web Site: www.tokmarcontrols.com Product design, software and literature are Copyright Q 2011 by: i of 1 All specifications are subject to change without notice. A' tekrnar Control Systerns Ltd. and lekniar Control Systems, Inc. Printed in Canada. C090 - 0101. 1,14! Job Designer Contact >' C 491 01/11 ................... Snow Melling Replaces: New The Snow /Ice Sensor Socket 091 is designed to provide a mounting solution for the Automatic Snow /Ice Sensor 090 or 094. It is intended to be installed directly into a concrete slab when the slab is poured, so that the 090 or 094 can be installed into it once dry. Specifications ................. .... ...................... ...- ........ Snow / Ice Sensor Socket 091 Literature D090 Packaged weight 1.5 lb (670 g), silicon brass Dimensions 3- 13/16" H x 3 -112 O.D. (97 x 89 O.D. mm) Approvals CSA C US with tekmar Snow / Ice Sensor 090 Warranty Limited 3 Year (See D090 for full warranty) SPECIAL REQUIREMENTS Must be mounted on a level slope, so that 090/094 sensor is flush with slab surface. Featu res .............................. ............................... • Provides mounting solution for Automatic Snow /Ice Sensor 090 or 094 tekMar tekmar Control Systems Ltd., Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road, Control Systems Vernon, B.C. Canada V1 B 3K4,250-545-7749, Fax. 250 - 545 -0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright c) 2011 by: 1 of 1 All specifications are subject to change without notice. 4'9k tekmar Control Systems Ltd. and tekmar Control Systems, Inc. Printed in Canada. C091 •01111. V