HomeMy WebLinkAboutDRB110466 approved plansPROJECTNORTH
DRIVEWAYEXPANSION
FACADEREMODEL
(2) SHED ROOFADDITIONS
DECKADDITION
MATCH ASPHALTMATCH GRADE
SEE SURVEY FORRIDGE ELEVATIONS
EXISTINGPATIO
RAILING REMODEL
3
'
-
6
3
/
4
"
2' - 9"
SNOW STORAGE NOTE:DRIVEWAY AREAEXISTING =
1,845 SQ. FT.
NEW =
294 SQ. FT.
TOTAL =
2,139 SQ FT.
REQUIRED SNOW STORAGE AREA30% OF TOTAL =
641 SQ. FT.
PROPOSED AREA = 650 SQ. FT.
SNOW STORAGEAREA SHOWNHATCHED
CONTRACTOR TO BUILD PHASEII DECK AROUND EXISTINGTREES
13'-6".
11' - 0"14' -0".
970.328.5151 OFFICE
PO Box 1587, Eagle, CO 81631
www.martinmanleyarchitects.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:21:58 AM
1481 Aspen Grove Lane Vail, CO 81657 A1.1
SITE PLAN + INFO
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
1" = 10'-0"
1
SITE PLAN
LOT AREA = .587 ACRES x 43,560 SQ. FT.
= 25,569 SQ. FT.SITE COVERAGE ALLOWED (20% OF SITE) = 5,114 SQ. FT.SITE COVERAGE PROPOSED
= 1,935 SQ. FT
ZONING SUMMARYGRFA PROPOSED:
TOTAL =3,373 SQ. FT.(SEE SHEET A1.2 FOR CALCS)
HEIGHT LIMIT = 33'-0"PROPOSED HEIGHT = 32'-9 1/2"PARKING SPACES REQUIRED:
3 SPACES
PARKING SPACES PROPOSED:
3 SPACES
Single Family ResidenceOwner:
Conrad & Kristina Suszynski2700 E Willamette LaneGreenwood Village, CO 80121
Location:
1481 Aspen Grove Lane, Vail, ColoradoLot 1, Block 2, Lions Ridge Filing 4
Parcel #:
2103-014-15-001Class of Work:
Renovation/addition
Type of Construction:
Type V-N
Type of Occupancy:
R3 (single family)
Levels:
2-story +basement
Architect:
Martin Manley Architect - Jeffrey P ManleyPO Box 1587 Eagle, CO 81631970.328.5151·GRFA ALLOWED :
25% lot area < 12,500 s.f. = 3,125 s.f.
10% lot area > 12,500 s.f. = 1,306 s.f.
Total =
4,431 s.f.
EXTERIOR:1. (3) shed roof additions (within existing larger roof)2. Change roofing material from cedar shingles to standing seam metal roofing.3. Addition of large glass doors leading to existing patio - North Elevation.4. Reconfigure Living Room windows and fireplace - South Elevation.5. Reconfigure Master Bedroom windows - Upper Level - South Elevation.6. Expand Dining Room (remove bay window) - West Elevation.7. Replace front door with new custom door / sidelights.8. Replace balcony railing - South Elevation.9. New deck and railing w/ sunken hot tub - West Elevation.INTERIOR:1. Remodel Living Room, open up walls, and change location of fireplace.2. Expand Dining Room and create more window area.3. Replace and redesign entire Kitchen and add french door.4. Re-design of entire east side of Main Level baths and closets.5. Master Bath pop-up roof, remodel.6. Master Bed - create walk-in-closet.7. Stairs - straighten angled riser.
GRFA CALCULATIONSBASEMENT CALCULATIONS:
(SEE SHEET A1.2)
TOTAL WALL SURFACE
= 1,668 S.F.
TOTAL EXPOSED WALL SURFACE
= 726 S.F.
PERCENTAGE EXPOSED WALL SURFACE
= 43%
PERCENTAGE UN-EXPOSED WALL SURFACE = 57%1 - LIVING AREA - EXIST
= 1,221 S.F.
1 - GARAGE - EXIST
= 537 S.F.
1 - GARAGE DEDUCTION
= (-537 S.F.)
1 - PRE-TOTAL
= 1,221 S.F.
BASEMENT DEDUCTION
= (-525 S.F.) (43%)
LEVEL 1
- GRFA TOTAL
= 696 S.F.
2 - LIVING AREA - EXIST
= 1,892 S.F.
2 - VAULTED 16' - EXIST
= 48 S.F.
2 - LIVING AREA - NEW
= 43 S.F.
LEVEL 2
GRFA TOTAL
= 1,935 S.F.
3 - LIVING AREA - EXIST
= 673 S.F.
3 - LEVEL AREA - NEW
= 21 S.F.
LEVEL 3
GRFA TOTAL
= 694 S.F.
GRFA - EXIST
= 3,309 S.F.
GRFA - NEW
= 64 S.F.
TOTAL GRFA
=3,373 S.F.VAULTED SPACES TALLER THAN 16'-0"
= 48 S.F.Drawing List
Sheet NumberSheet NameA1.1SITE PLAN + INFOA1.2AREA PLANS AND GRFA SUMMARYA2.1LOWER & MAIN PLANS & DEMOA2.2UPPER AND ROOF PLANA3.1Exterior ElevationsA3.2Exterior ElevationsA4.1LARGE SCALE BLDG SECTIONA4.2SECTIONSA5.1KITCHEN DETAILSA5.2DetailsGrand total: 10TOWN OF VAIL ZONING DISTRICT:SFR SINGLE-FAMILY RESIDENTIAL
No.DescriptionDate
1Revision 1- V-ENGR 109.15.11
SETBACKS: FRONT = 20', SIDE = 15', REAR = 15'PROJECT / CODE SUMMARYPROJECT DESCRIPTION:
TOPOGRAPHIC SURVEY (NOT TO SCALE)1481 Aspen Grove Lane, Vail, Colorado
Suszynski Renovation
DN
1143 SF
EXISTING LIVINGAREA
78 SF
EXISTING LIVINGAREA 2
537 SF
GARAGE AREA
1892 SF
EXISTING LIVINGAREA
28 SF
NEW LIVING AREA 1
695 SF
EXISTING LIVINGAREA
26 SF
NEW LIVING AREA48 SF
16' VAULTED AREA
STAIROPENING ONUPPERLEVEL DOESNOT COUNTFOR GRFA
AREA OF "EXPOSED" WALL (RED) = 62 SQ.FT.AREA OF TOTAL WALL (HATCH) = 413 SQ.FT.
AREA OF "EXPOSED" WALL (RED) = 24 SQ.FT.AREA OF TOTAL WALL (HATCH) = 371 SQ.FT.
AREA OF "EXPOSED" WALL (RED) = 403 SQ.FT.AREA OF TOTAL WALL (HATCH) = 420 SQ.FT.
AREA OF "EXPOSED" WALL (RED) = 237 SQ.FT.AREA OF TOTAL WALL (HATCH) = 464 SQ.FT.
1892 SF
SITE COVERAGE -EXISTING
15 SF
SITE COVERAGE -NEW 2
28 SF
SITE COVERAGE -NEW 1
970
.328
.5151
O
FF
IC
E
PO
B
o
x
1587
, E
ag
le
, CO 81631
www
.ma
r
tinman
le
ya
rch
ite
cts
.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:22:04 AM
1481 Aspen Grove Lane Vail, CO 81657 A1.2
AREA PLANS AND GRFA
SUMMARY
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
1/8" = 1'-0"
1
01.0 Lower Floor
1/8" = 1'-0"
2
02.0 Main Floor
1/8" = 1'-0"
3
03 Upper Level
1" = 10'-0"
4
East Elevation - COPY
1" = 10'-0"
5
North Elevation - COPY
1" = 10'-0"
6
South Elevation - COPY
1" = 10'-0"
7
West Elevation - COPY
Area Schedule (16' Vaulted Area)NameAreaLevel
16' VAULTED AREA48 SF03 Upper Level48 SF
Area Schedule (Garage Existing)NameAreaLevel
GARAGE AREA537 SF01.0 Lower Floor537 SF
Area Schedule (Living All)
NameAreaLevelNEW LIVING AREA 2Not PlacedNot PlacedEXISTING LIVING AREA1143 SF01.0 Lower FloorEXISTING LIVING AREA 278 SF01.0 Lower FloorEXISTING LIVING AREA1892 SF02.0 Main FloorNEW LIVING AREA 128 SF02.0 Main FloorEXISTING LIVING AREA695 SF03 Upper LevelNEW LIVING AREA26 SF03 Upper Level3862 SF
Area Schedule (Living Existing)NameAreaLevel
EXISTING LIVING AREA1143 SF01.0 Lower FloorEXISTING LIVING AREA 278 SF01.0 Lower FloorEXISTING LIVING AREA1892 SF02.0 Main FloorEXISTING LIVING AREA695 SF03 Upper Level3808 SF
Area Schedule (Living New)
NameAreaLevelNEW LIVING AREA 2NotPlaced
Not Placed
NEW LIVING AREA 128 SF02.0 Main FloorNEW LIVING AREA26 SF03 Upper Level54 SF
1" = 20'-0"
8
02.0 Main Floor
Area Schedule (Site Coverage)NameAreaSITE COVERAGE - EXISTING1892 SFSITE COVERAGE - NEW 215 SFSITE COVERAGE - NEW 128 SFGrand total: 31935 SF
No.DescriptionDate
1Revision 1- V-ENGR 109.15.11
DN
DN
DN
DN
DW
DN
REF.
DW
REF.
UP
DN
DN
DN
UP
DN
UP
DN
1
A4.1
1
A4.2
2
A4.2
3
A4.2
NEW DECK AND RAILINGNEW DECK TO BE CUT AROUNDEXISTING ASPEN TREE
NEW DECKAT THE SAMEELEVATIONAS EXISTINGDECK
EXISTING DECK STRUCTURE WITH NEW DECKINGSURFACE AND NEW RAILING
NEW RAILING
5
A4.2
8' - 8 1/4"7' - 4 13/16"5' - 6 5/8"
4
A4.2
11' - 6"
5 1/2"7' - 3 3/4"
X 7'-6
" tall un
it
3 panel sliding door w/ one operable panel
9' - 0" unit width1' - 8 1/2"11' - 0 1/2"
5 1/2"
(3) 36" wide X20" tall operable units in transom
12' - 11 15/16"5 1/2"2' - 10 3/8"5 1/2"
1' - 3"8"
X 9'-0" tall unit
4 panel sliding door w/ two operable center panels12' - 0" unit width
9"
4 1/2"
5' - 0"
1' - 8 1/4"
EXISTING EDGEOF FLOOR
CLAD COL. WITH WOOD TRIM7 1/2" x7 1/2". WALL BETWEENCOLUMNS.
DOWN DRAFT HOOD, VENTTHRU GARAGE AND TOWEST EXTERIOR WALL
3' - 8 3/4"1' - 5"1' - 5"
1' - 10"
5 1/2"
6' - 1 1/2"
2' - 8"
3' - 10 1/2"
3' - 0"
6' - 0 7/8"
existing opening
4' - 0 3/4"
3' - 6 1/4"8' - 2"
FIREPLACE FLUE(2) 30x72 CLAD CASEMENT WDWSABOVE (2) 30x20 CLAD AWNING WDWSFIXED UNITS WITHIN 3'-0" OF FLUE
Gas fireplace applianceHeat-N Glo 8000C(confirm with owner)
ST tileWD
ST tile WD
ST tile cpt
reuse
existing door
reuseexisting door
2' - 2"
existing
door
existingdoor
existing
door
existingdoor
6 1/2"
8"
1' - 2"
ST tile
WD
UPPER PANTRYCABINETS TO EXTENDFROM COUNTER TOCEILING
NEW IRON HANDRAIL
7' - 11 1/4"
NEW BUILT-IN BOOKCASE/CABINET
32"x80"
reuse existing32" linen bathdoor
UP
CLAD EXISTING BEAMWITH WOOD TRIMNEW COL. ONEX. GAR. BEAM
DINING100
KIT
101
LIVING RM102
HALL103
ALCOVE104
BEDROOM105
CLO106
PWDR108 BEDROOM109
CLO110
BATH111
NEW BATH FAN.VENT TO THE EASTNEW POWDER ROOM TOILETAND SINK TO TIE INTOEXISTING WATER, WASTEAND VENTING PLUMBINGLINES
REWORK EXISTING BASE BOARDHEAT AND ADD A 'SNAP-LOCK'RADIANT SYSTEM WITHIN THELIVING ROOM
REWORK EXISTINGBASE BOARD HEATAND ADD A STAPLEUP RADIANTSYSTEM UNDERTHE FLOORSHEATHING OF THEDINING ROOM ANDKITCHEN
NOTE:EXISTING BATH FANS IN BATH 111 ANDBATH 107 ARE TO REMAIN
HOT TUB ELECTRICALDISCONNECT LOCATION
5' - 5 3/8"
2' - 7 1/4"
1 1/2"
2' - 7 1/4"
ST tilecpt
EXISTING TLTLOCATION.
2' - 2"
5 1/2"
5' - 6"
1' - 0"
WOOD PANEL
2' - 8 1/2"BATH107
REMOVESOFFIT
SM CO
SMOKE DETECTORCO DETECTOR
SMSM
CO
SM
LEGENDexisting or newExisting detectors do notneed to be relocated
2' - 11"
3-panel folding door with 3 operable transom units8'-8" unit width
5 1/2"
x 7'-6" tall unit
3- panel folding door8'-8" unit width
2' - 9"
VERIFY CLEARANCE OFGUTTER AND KEEP DOORASSEMBLY AS FAR WESTAS POSSIBLE
NEW COLUMNBELOW
NEW COLUMNBELOW
16' - 1 3/16"
4' - 5"3' - 5 1/4"
2' - 8"
5' - 4"
bath light switch
2 1/2"
A5.11
oven
11' - 6"
14' - 0"
3' - 6"10' - 0"
2' - 6 3/4"
10' - 9"9' - 3"11' - 6"
REUSEEXISTINGDOOR ATNEWPOWDERROOM
REUSE EXISTINGDOOR AND JAMBAT NEWBEDROOMOPENING
EXISTINGFIREPLACE, FLUE,AND STONEWORKIS TO BEREMOVED
EXISTING BEAM TOBE CLEANED ANDPREPARED FORNEW STAINEDFINISH. OPTIONOF CLADDING INNEW MATERIALACCEPTABLE
NEW MECH.FLUE TO RUNWITHIN STAIRWALL
8' - 0 3/4"
13' - 6"
16' - 6 1/2"
10' - 8 5/8"
REMOVEDEXISTINGCHIMNEY
1
A4.1
1
A4.2
2
A4.2
5
A4.2
4
A4.2 NEW ENTRY DOORWITH SIDELITE
Phase II(NOT IN CURRENT SCOPEOF WORK)ROSE SANDSTONE ISSEALED WITH A COLORTINTING SEALER TOREMOVE THEREDDISH/PINK COLORLAYOUT OF WASHERAND DRYER ANDCOUNTERTOPS ARETO BE REWORKEDWITHIN LAUNDRYROOMNEW IRON HANDRAILPhase II(NOT IN CURRENT SCOPEOF WORK)PORTION OF EXISTINGWALL TO BE CUT DOWNTO CURB HT AND A NEWGUARD RAIL TO MATCHEXISTING IS TO BEINSTALLED
CLAD COL.WITH WOODTRIM7 1/2" x7 1/2".
Phase II(NOT IN CURRENT SCOPE OFWORK)NEW CABINETRY CUBBIES ARETO BE CUT IN UNDER THEEXISTING STAIRCONSTRUCTION AND PROJECTINTO THE MECH ROOM 2'-0".
14' - 6"9' - 8"
GARAGE001
ENTRY002
REWORK EXISTINGGARAGE DOOROPENING TOELIMINATE THEARCHED OPENING.REPAIR THE STONEWORK AS REQUIRED.
REPAIR EXISTING STONE ASREQUIRED FOR NEW DOOR SIZE.REPAIR EXISTING CEILING FORDELETION OF SOFFIT OVER THEDOOR.
SM CO
SMOKE DETECTORCO DETECTORLEGENDexisting or newExisting detectors do notneed to be relocated
SM
SM
SM
CO
NEW ENTRY DOOR WITHSIDELITES
Phase II (NOT IN CURRENTSCOPE OF WORK)ROSE SANDSTONEIS SEALED WITH ACOLOR TINTINGSEALER TOREMOVE THEREDISH/PINK COLORPhase II(NOT IN CURRENTSCOPE OF WORK)PORTION OFEXISTING WALL TOBE CUT DOWN TOCURB HT AND ANEW GUARD RAILTO MATCHEXISTING IS TO BEINSTALLED
970
.328
.5151
O
FF
IC
E
PO
B
o
x
1587
, E
ag
le
, CO 81631
www
.ma
r
tinman
le
ya
rch
ite
cts
.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:22:07 AM
1481 Aspen Grove Lane Vail, CO 81657 A2.1
LOWER & MAIN PLANS &
DEMO
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
1/4" = 1'-0"
1
02 Main Floor - New
1/8" = 1'-0"
2
02 Main Floor Existing
No.DescriptionDate
1Revision 1- V-ENGR 109.15.11
1/8" = 1'-0"
4
03 Upper Level - Existing
1/4" = 1'-0"
3
01 Lower Floor- New
1/8" = 1'-0"
5
01 Lower Floor Existing
INSULATION VALUES/ENERGY CODENEW WALLS: R-23 BLOWN-IN INSULATIONNEW CANTILEVERED FLOORS: R-38 BLOW-INNEW ROOF STRUCTURE/CLG: R-49 BLOWN-INWINDOWS AND PATIO DOORS: U-VALUE .35GENERAL ELECTRICAL NOTETHE REVISION/RELAYOU
T OF THE ELECTRICALAND LIGHTING WITHIN THE HOME SHALL BEINSTALLED WITHOUT THE ADDITION OFADDITIONAL CIRCUITS.THE NEW HOT TUB SHALL HAVE A DISCONNECTLOCATED AT THE SOUTH IF THE NEW DININGROOM WEST DOOR ASSEMBLY.
DN
16' - 6"
13' - 6"
17' - 9"17' - 9"
1
A4.1
1
A4.2
2
A4.2
3
A4.2
5
A4.2
4
A4.2
AT ENTIRE ROOF- ALL EXISTING WOOD SHAKEROOFING IS TO BE REMOVED AND NEW METALSTANDING SEAM IS TO BE INSTALLED. NEWMETALL ROOFING ON FULL COVERAGE WATERPROOF MENBRANE ON ROOF SHEATHING ONINSULATED RAFTERS.REPAIR EXISTING ROOF SHEATHING ASREQUIRED.MAINTAIN EXISTING ROOF VENTIATIONALL NEW ROOF AREAS TO RECIEVE R-49INSULATION WITHIN THE CAVITY. REFER TOSECTIONS.
2" / 12"
2" / 12"8" / 12"
8" / 12"8" / 12"
8" / 12"
8" / 12"
8" / 12"
8" / 12"
8" / 12"
8" / 12"
8" / 12"
8" / 12"
SHADED AREAARE AREAS OFNEW ROOFSTRUCTUREORSTRUCTURETHAT IS BEINGREPLACED
NEW SNOW FENCESNEW SNOW FENCE
NEW SNOW FENCE
1
A4.1
1
A4.2
2
A4.2
OFFICE
(3) 30x30 CLADAWNINGWINDOWS(HDR HT 7'-7 1/2"A.F.F.)
NEW GLASSSHOWER
NEW VANITY. COORDINATEWITH OWNER'S CABINETDESIGNER VERIFYLOCATION NEW OFPLUMBING
LIGHT SHELF
3
A4.2
5
A4.2
4
A4.2
1' - 3"4' - 3 1/2"3' - 1"7' - 0 1/2"12' - 0"5'-5".
5' - 3"
2' - 1"3' - 3"2' - 6"2' - 6"2' - 1"
5' - 10 1/2"
2' - 0 5/8"
4' - 5"
2' - 0"EQ
2'-6".
EQ
5'-11".
2' - 7 1/4"12' - 5"(1) 30x30 CLADAWNINGWINDOWS(HDR HT 7'-7 1/2"A.F.F.)
reuseexisting door
reuseexisting door
REUSE (2) 2'-0"x7'-0"CLOSET DOORS ONBARN DOOR TRACK.
EXISTING WINDOWSEXISTING WINDOWS
EXISTING WINDOWS
MASTER
BEDROOM201
OFFICE202
CLOSET203M.BATH204
WC205
REWORK EXISTINGBASE BOARDHEATER TO BE AEUROPEAN STYLERADIATOR
NOTE:BATH FAN IN BATH 205SM CO
SMOKE DETECTORCO DETECTORLEGENDexisting or newExisting detectors do notneed to be relocated
SM
SM
CO
COORDINATE FLAT CEILING HEIGHT WITH ARCH. OWNER
NEW TUB
1' - 1 1/2"
5' - 0"
2' - 6"10"
970
.328
.5151
O
FF
IC
E
PO
B
o
x
1587
, E
ag
le
, CO 81631
www
.ma
r
tinman
le
ya
rch
ite
cts
.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:22:24 AM
1481 Aspen Grove Lane Vail, CO 81657 A2.2
UPPER AND ROOF PLAN
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
1/4" = 1'-0"
1
04 Roof Plan - New
No.DescriptionDate
1Revision 1- V-ENGR 109.15.11
2
EXT - NORTH DECK - LOOKING SOUTH
4
EXT - FRONT ELEVATION- LOOKINGNORTH
5
FRONT ISOMETRIC
6
REAR ISOMETRIC
1/4" = 1'-0"
3
03 Upper Level - New
02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6"
8' - 0"9' - 0"9' - 0"
26' - 0"
1
A4.2
33' - 0"
8463' - 6"
8429' - 6"
MAXIMUM HEIGHT
NOT TO EXCEED
NEW BALCONY RAILING:AUSTRIAN STYLE
8"
12"
2"
12"
NEW LIVING ROOMWINDOWS / DOORS
NEW ENTRY DOOR / SIDELITENOTE - RIDGE ELEVATIONSSEE "PEAK LAND CONSULTANTS" SURVEYDATED 4-13-11
5
A4.2
REMOVE CHIMNEYNEW SHED ROOF
8447' - 7"
CONFIRM CLEARANCESFOR NEW FIREPLACEDIRECT VENT FLUE
NEW
NEW
EXISTINGDININGWINDOWREUSED(ARCHED TOPWINDOWREMOVED)
EXISTING
EXISTING
EXISTING
EXISTING
REPAIR EXISTING FINISHESAROUND NEW DOOR ANDWINDOW LOCATIONS
EXISTING GARAGE DOOR TO BECLAD WITH NEW TRIMSTONE AT REMOVED ARCH TOPSTONE IS TO BE REPAIREDUSING EXISTING STONE
NEW SHED ROOFFASCIA TO MATCH EXISTING
TIMBER
OUTLOOKER
SNOW FENCE
8' - 0"
3' - 3"
5' - 11 3/4"NEW3' - 6"
02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6"
1
A4.1
2
A4.2
3
A4.2
MASTER BATH DORMERNEW SHED ROOFNEW WALL / WINDOWSDINING ROOM ROOFNEW SHED ROOFNEW WALL / WINDOWS
EXISTING CHIMNEY(REMOVED)
NEW METAL ROOF:STANDING SEAMRust COLORNEW RAILINGAUSTRIAN STYLE
NEW DINING ROOM WINDOWS(RE-USE DEMO WQINDOW AT BATH)
4
A4.2
2" / 12"2" / 12"
NEW SNOW FENCES
NEW SNOW FENCES
14'-0".
970
.328
.5151
O
FF
IC
E
PO
B
o
x
1587
, E
ag
le
, CO 81631
www
.ma
r
tinman
le
ya
rch
ite
cts
.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:22:40 AM
1481 Aspen Grove Lane Vail, CO 81657 A3.1
E
x
te
r
io
r
E
leva
t
ion
s
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
1/4" = 1'-0"
2
South Elevation - NEW 1/4" = 1'-0"
1
West Elevation - NEW
1/8" = 1'-0"
3
South Elevation - EXISTING 1/8" = 1'-0"
4
West Elevation EXISTING
No.DescriptionDate
1Revision 1- V-ENGR 109.15.11
02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6"
EXISTING ROOF/WALL / WINDOWSSIDING & TRIM
02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6"9' - 0"9' - 0"8' - 0"
1
A4.2 2"
12"
2"
12"
NEW
NEW
NEW DBL FASCIA(MATCH EXISTING)NEW SIDING /TRIM(MATCH EXISTING)NEW STUCCO(MATCH EXISTING)
NEW SIDING /TRIM(MATCH EXISTING)
5
A4.2
8448' - 8 1/2"BTM OF HDR
EXISTING
EXISTINGEXISTINGEXISTING
DOOR HEADSTO ALIGN
3 1/2"1' - 11"2 1/2"3"2"
7 1/2"
3 13/16"
2' - 11 13/16"
7 1/2"5 1/2"
7/8"
4 1/4" picket spacing.(<4" clear opening between)
970
.328
.5151
O
FF
IC
E
PO
B
o
x
1587
, E
ag
le
, CO 81631
www
.ma
r
tinman
le
ya
rch
ite
cts
.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:22:56 AM
1481 Aspen Grove Lane Vail, CO 81657 A3.2
E
x
te
r
io
r
E
leva
t
ion
s
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
1/4" = 1'-0"
2
East Elevation - NEW 1/4" = 1'-0"
1
North Elevation - NEW
1/8" = 1'-0"
3
East Elevation -EXISTING
1/8" = 1'-0"
4
North Elevation -EXISTING
No.DescriptionDate
1Revision 1- V-ENGR 109.15.11
1" = 1'-0"
5
mtl picket Deckrailing detail
02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6"
1
A4.2
5' - 0"3' - 9 3/4"
NEW 30x30 CLAD AWNING WINDOWSNEW SHED ROOF WITH STANDING SEAMROOFING ON FULL COVERAGEWATERPROOF MEMBRANE ON ROOFSHEATHING ON 2x ROOF RAFTERS.INSULATE THE ROOF STRUCTURE WITHBLOWN-IN INSULATION (R-49)
NEW SHED ROOF
EXISTING BEAMCLAD WITH MEW WOOD TRIM.PROVIDE MARINE POLY. COAT DUETO WET LOCATION OFSHOWER/BATHROOM
5
A4.2
2" / 12"
2" / 12"
8' - 9 3/4"
5 1/2"
PROVIDE NEW FLAT CEILING AT SPRING POINT.INSULATE THE ROOF STRUCTURE AND CAVITY WITH BLOWN-ININSULATION (R-49)
MATCH EXISTING ROOF FASCIA DETAIL
OVERHANG1' - 11 5/8"
8456' - 1 1/2"BTM OF HDR
7' - 7 1/2"
8449' - 7 3/4"
10' - 1 3/4"
8457' - 3 3/4"PLATE HT
PLATE HT
1' - 11 5/8"
MATCH EXISTING ROOF FASCIA DETAIL
11 1/4"
9' - 2 1/2"11 1/4"
PROVIDE SLOPE ONLIGHT SHELF TILEDSURFACE FORDRAINAGE
12' - 0 3/4"
BLOWN-ININSUALTION R-23PROVIDE WALL TO ROOFFLASHING AND COUNTERFLASHING. FULLY COVERSIDE WALLS WITH FLASHING
8448' - 8 1/2"BTM OF HDR
6"
NEW STONE TILE FLOORINGIN KITCHEN AND DINING
COORDINATE DESKSTRUCTURE TO SPAN OVEREXISTING SHED ROOF
EXISTING BEAM TO BE CLEANEDAND PREPARED FOR NEW FINISHOR CLAD WITH NEW WOOD TRIM
CLAD COL. WITH WOOD TRIM 7 1/2" x7 1/2".PROVIDE SHELVING BETWEEN COLUMNS.CONFIRM SPACING WITH OWNER
10' - 0"
NEW DROPPED CLGCOORDINATE HT WITHARCHITECT OR OWNERBEFORE FRAMINGNEW SHOWER CURBAND PAN. CONNECTDRAIN TO EXISTINGPIPINGPHASE IIROSE SANDSTONG IS TOBE REPLCED WITHCOLORADO BUFFCOLOORED SANDSTONE.(CAUTION: THERE IS HEATPIPING WITHIN THE MOTARBED OF THE EXISTINGSTONE)PHASE IIPORTION OF EXISTINGWALL TO BE CUT DOWNTO CURB HT AND A NEWGUARD RAIL TO MATCHEXISTING IS TO BEINSTALLED
PHASE IINEW CABINETRY CUBBIESARE TO BE CUT IN UNDERTHE EXISTING STAIRCONSTRUCTION ANDPROJECT INTO THE MECHROOM 2'-0".
KIT
101
DINING100
HALL103
BEDROOM105
GARAGE001
ENTRY002
M.BATH204
A5.12
A5.14
970
.328
.5151
O
FF
IC
E
PO
B
o
x
1587
, E
ag
le
, CO 81631
www
.ma
r
tinman
le
ya
rch
ite
cts
.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:22:58 AM
1481 Aspen Grove Lane Vail, CO 81657 A4.1
LARGE SCALE BLDG SECT
ION
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
No.DescriptionDate
1Revision 1- V-ENGR 109.15.11
1/2" = 1'-0"
1
LARGE SCALE BUILDING SECTION
02.0 Main Floor8439' - 6"03 Upper Level8448' - 6"
1
A4.1
2
A4.2
4
A4.2
6"
NEW STEPS
LIVING RM102
DINING100
02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6"
1
A4.2
NEWWINDOWS ANDDOORS
3' - 0"16' - 0"
5
A4.2
1' - 0"
THIN STONE2 1/2"
1' - 4"
8"
THIN STONE2 1/2"
4"
7 13/16"1' - 2"
2' - 0"
12"x6" TIMBER
Gas fireplace applianceHeat-N Glo 8000C(confirm with owner)
FIREPLACE VENT.PROVIDE PROPERCLEARANCES AND 1HOUR RATED CHASETO EXTERIOR
LIVING RM102
MASTER
BEDROOM201
GARAGE001CLAD EXISTING BEAMWITH WOOD TRIM
EXISTING WALLCONSTRUCTION.REMOVED EXISTINGSOFFIT ABOVE THATVANITY AND TLT
OFFICE202
8' - 0"
02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6"
1
A4.2
8449' - 7 3/4"
LIVING RM102CLOSET203
GARAGE001
NEW SHED ROOF WITHSTANDING SEAM ROOFINGON FULL COVERAGEWATERPROOF MEMBRANEON ROOF SHEATHING ON 2xROOF RAFTERS. INSULATETHE ROOF STRUCTURE WITHBLOWN-IN INSULATION (R-49)PLATE HTNEW WALLCONSTRUCTION ANDEXTENED FLOORCONSTRUCTION.PROVIDE BLOWN-ININSUALTION R-23 ATWALL AND R-49 INFLOOR.
CLAD EXISTINGBEAM WITHWOOD TRIM
NEWCABINETWITHINWALL VOID
CLAD COL. WITH WOODTRIM 7 1/2" x7 1/2".PROVIDE SHELVINGBETWEEN COLUMNS.CONFIRM SPACING WITHOWNERCLAD NEW BEAM
MATCH EXISTING ROOFFASCIA DETAIL AND WALLSIDING
FLASHING
PROVIDENEWDROPPEDCLG AT CLO
CLOSET ROD,SHELVING ANDPANT HANGINGSYSTEM TO BEDESIGNED ANDAPPROVED BYTHE OWNR
02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"03 Upper Level8448' - 6"
4' - 0"
8' - 0"
CLAD COL. WITH WOOD TRIM 71/2" x7 1/2". PROVIDE SHELVINGBETWEEN COLUMNS. CONFIRMSPACING WITH OWNER
WOODPANELING
970
.328
.5151
O
FF
IC
E
PO
B
o
x
1587
, E
ag
le
, CO 81631
www
.ma
r
tinman
le
ya
rch
ite
cts
.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:23:01 AM
1481 Aspen Grove Lane Vail, CO 81657 A4.2
SECTIONS
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
No.DescriptionDate
1Revision 1- V-ENGR 109.15.11
1/4" = 1'-0"
1
SECTION THRU LIVING AND DININGLOOKING WEST
1/4" = 1'-0"
2
SECTION THRU LIVING ROOM ANDFIREPLACE
1/4" = 1'-0"
3
SECTION THRU BATH 107
1/4" = 1'-0"
4
SECTION THRU LIVING LOOKING NORTH
1/4" = 1'-0"
5
LIVING ROOM - FIREPLACE
DN
DW
DN
REF.
DW
REF.
2 1/2"
30" built-in sub zero
2' - 6"3/4"2' - 7 1/2"
BC
7 1/2"
Wolf Dbl OVEN DO30-2U/S
2' - 6"3"
doubleoven
END PANEL
2' - 0"
Wolf 36" Ind CT36 w/ DB
3' - 0"
SPICE
1' - 0"3' - 0"
DB
9 1/2"
2 1/2"
SINK BASE3' - 0"
2 1/2"
DISHWASHER2' - 0"
1 1/2"
2' - 4 3/4"2 5/8"
CB
2' - 9"
DB
2' - 9"
DB
2' - 9"
CB
2' - 9"
3' - 1 3/4"
1 1/2"
1 1/2"3 1/2"
1/2"
2' - 0"1"
8' - 10 3/4"5' - 6 1/2"
2' - 0"
4' - 0"
END PANEL2' - 0"
DB
1' - 2"
DB short1' - 2"
END PANEL2' - 0"
DOWN DRAFT CHASE
OUTLETON SIDE
OUTLETON SIDE
OUTLETBACK OFCAB FORGB AND DWGD BATCHFEED SWITCH
PLUG MOLDOUTLET INSIDE(ABOVECOUNTER)
(3) SWITCHES INSIDE PANEL
DB
2' - 0"
DB
2' - 0"
END PANEL
2' - 0"
OUTLET
ON SIDE
6' - 4"
6' - 0"
3' - 1 3/4"
3' - 0"
3"
2' - 6"
7 1/2"
2' - 0"
7 1/2"
3/4"
2' - 6"2 1/2"
1 1/2"
ref
coordinateclosure trim
panel
Sub-Ze
ro BI 30UG w/ gls d
r
7' - 0"6"
3' - 3"
Sharp micro
Wolf dbl ovenDO30-2U/S
1' - 3 1/2"4' - 2"1' - 9"
5' - 9"
9 1/2"
2 1/2"
3' - 0"
2 1/2"
2' - 0"
1 1/2"
dishwasher
switches
end panel2' - 0"
cook top and DB3' - 0"
spice
1' - 0"
end panel2' - 0"
DB
1' - 2"
DB short1' - 2"
end panel2' - 0"
DB
2' - 0"
DB
2' - 0"
end panel2' - 0"
970
.328
.5151
O
FF
IC
E
PO
B
o
x
1587
, E
ag
le
, CO 81631
www
.ma
r
tinman
le
ya
rch
ite
cts
.com
P
ro
je
ct num
ber
D
ateR
EV
IS
IONS
9/26/2011 8:24:18 AM
1481 Aspen Grove Lane Vail, CO 81657 A5.1
KITCHEN DE
TAILS
1105Suszynski Renovation
REVISED PERMIT SET
9-15
-11
-
No.DescriptionDate
1/2" = 1'-0"
1
KITCHEN PLAN of 02 Main Floor - New 1/2" = 1'-0"
2
BAR CABINETRY
1/2" = 1'-0"
3
EAST KITCHEN CABINETRY
1/2" = 1'-0"
4
SOUTH SIDE OF ISLAND CABINTRY
1/2" = 1'-0"
5
EAST SIDE OF ISLAND CABINETRY
1/2" = 1'-0"
6
NORTH SIDE OF ISLAND CABINETRY
1/2" = 1'-0"
7
WEST SIDE OF ISLAND CABINETRY8
3D View 1
9
Copy of INT - DR - LOOKING TOWARDKITCHEN
10
3D View 6