Loading...
HomeMy WebLinkAboutDRB110466 approved plansPROJECTNORTH DRIVEWAYEXPANSION FACADEREMODEL (2) SHED ROOFADDITIONS DECKADDITION MATCH ASPHALTMATCH GRADE SEE SURVEY FORRIDGE ELEVATIONS EXISTINGPATIO RAILING REMODEL 3 ' - 6 3 / 4 " 2' - 9" SNOW STORAGE NOTE:DRIVEWAY AREAEXISTING = 1,845 SQ. FT. NEW = 294 SQ. FT. TOTAL = 2,139 SQ FT. REQUIRED SNOW STORAGE AREA30% OF TOTAL = 641 SQ. FT. PROPOSED AREA = 650 SQ. FT. SNOW STORAGEAREA SHOWNHATCHED CONTRACTOR TO BUILD PHASEII DECK AROUND EXISTINGTREES 13'-6". 11' - 0"14' -0". 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:21:58 AM 1481 Aspen Grove Lane Vail, CO 81657 A1.1 SITE PLAN + INFO 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - 1" = 10'-0" 1 SITE PLAN LOT AREA = .587 ACRES x 43,560 SQ. FT. = 25,569 SQ. FT.SITE COVERAGE ALLOWED (20% OF SITE) = 5,114 SQ. FT.SITE COVERAGE PROPOSED = 1,935 SQ. FT ZONING SUMMARYGRFA PROPOSED: TOTAL =3,373 SQ. FT.(SEE SHEET A1.2 FOR CALCS) HEIGHT LIMIT = 33'-0"PROPOSED HEIGHT = 32'-9 1/2"PARKING SPACES REQUIRED: 3 SPACES PARKING SPACES PROPOSED: 3 SPACES Single Family ResidenceOwner: Conrad & Kristina Suszynski2700 E Willamette LaneGreenwood Village, CO 80121 Location: 1481 Aspen Grove Lane, Vail, ColoradoLot 1, Block 2, Lions Ridge Filing 4 Parcel #: 2103-014-15-001Class of Work: Renovation/addition Type of Construction: Type V-N Type of Occupancy: R3 (single family) Levels: 2-story +basement Architect: Martin Manley Architect - Jeffrey P ManleyPO Box 1587 Eagle, CO 81631970.328.5151·GRFA ALLOWED : 25% lot area < 12,500 s.f. = 3,125 s.f. 10% lot area > 12,500 s.f. = 1,306 s.f. Total = 4,431 s.f. EXTERIOR:1. (3) shed roof additions (within existing larger roof)2. Change roofing material from cedar shingles to standing seam metal roofing.3. Addition of large glass doors leading to existing patio - North Elevation.4. Reconfigure Living Room windows and fireplace - South Elevation.5. Reconfigure Master Bedroom windows - Upper Level - South Elevation.6. Expand Dining Room (remove bay window) - West Elevation.7. Replace front door with new custom door / sidelights.8. Replace balcony railing - South Elevation.9. New deck and railing w/ sunken hot tub - West Elevation.INTERIOR:1. Remodel Living Room, open up walls, and change location of fireplace.2. Expand Dining Room and create more window area.3. Replace and redesign entire Kitchen and add french door.4. Re-design of entire east side of Main Level baths and closets.5. Master Bath pop-up roof, remodel.6. Master Bed - create walk-in-closet.7. Stairs - straighten angled riser. GRFA CALCULATIONSBASEMENT CALCULATIONS: (SEE SHEET A1.2) TOTAL WALL SURFACE = 1,668 S.F. TOTAL EXPOSED WALL SURFACE = 726 S.F. PERCENTAGE EXPOSED WALL SURFACE = 43% PERCENTAGE UN-EXPOSED WALL SURFACE = 57%1 - LIVING AREA - EXIST = 1,221 S.F. 1 - GARAGE - EXIST = 537 S.F. 1 - GARAGE DEDUCTION = (-537 S.F.) 1 - PRE-TOTAL = 1,221 S.F. BASEMENT DEDUCTION = (-525 S.F.) (43%) LEVEL 1 - GRFA TOTAL = 696 S.F. 2 - LIVING AREA - EXIST = 1,892 S.F. 2 - VAULTED 16' - EXIST = 48 S.F. 2 - LIVING AREA - NEW = 43 S.F. LEVEL 2 GRFA TOTAL = 1,935 S.F. 3 - LIVING AREA - EXIST = 673 S.F. 3 - LEVEL AREA - NEW = 21 S.F. LEVEL 3 GRFA TOTAL = 694 S.F. GRFA - EXIST = 3,309 S.F. GRFA - NEW = 64 S.F. TOTAL GRFA =3,373 S.F.VAULTED SPACES TALLER THAN 16'-0" = 48 S.F.Drawing List Sheet NumberSheet NameA1.1SITE PLAN + INFOA1.2AREA PLANS AND GRFA SUMMARYA2.1LOWER & MAIN PLANS & DEMOA2.2UPPER AND ROOF PLANA3.1Exterior ElevationsA3.2Exterior ElevationsA4.1LARGE SCALE BLDG SECTIONA4.2SECTIONSA5.1KITCHEN DETAILSA5.2DetailsGrand total: 10TOWN OF VAIL ZONING DISTRICT:SFR SINGLE-FAMILY RESIDENTIAL No.DescriptionDate 1Revision 1- V-ENGR 109.15.11 SETBACKS: FRONT = 20', SIDE = 15', REAR = 15'PROJECT / CODE SUMMARYPROJECT DESCRIPTION: TOPOGRAPHIC SURVEY (NOT TO SCALE)1481 Aspen Grove Lane, Vail, Colorado Suszynski Renovation DN 1143 SF EXISTING LIVINGAREA 78 SF EXISTING LIVINGAREA 2 537 SF GARAGE AREA 1892 SF EXISTING LIVINGAREA 28 SF NEW LIVING AREA 1 695 SF EXISTING LIVINGAREA 26 SF NEW LIVING AREA48 SF 16' VAULTED AREA STAIROPENING ONUPPERLEVEL DOESNOT COUNTFOR GRFA AREA OF "EXPOSED" WALL (RED) = 62 SQ.FT.AREA OF TOTAL WALL (HATCH) = 413 SQ.FT. AREA OF "EXPOSED" WALL (RED) = 24 SQ.FT.AREA OF TOTAL WALL (HATCH) = 371 SQ.FT. AREA OF "EXPOSED" WALL (RED) = 403 SQ.FT.AREA OF TOTAL WALL (HATCH) = 420 SQ.FT. AREA OF "EXPOSED" WALL (RED) = 237 SQ.FT.AREA OF TOTAL WALL (HATCH) = 464 SQ.FT. 1892 SF SITE COVERAGE -EXISTING 15 SF SITE COVERAGE -NEW 2 28 SF SITE COVERAGE -NEW 1 970 .328 .5151 O FF IC E PO B o x 1587 , E ag le , CO 81631 www .ma r tinman le ya rch ite cts .com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:22:04 AM 1481 Aspen Grove Lane Vail, CO 81657 A1.2 AREA PLANS AND GRFA SUMMARY 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - 1/8" = 1'-0" 1 01.0 Lower Floor 1/8" = 1'-0" 2 02.0 Main Floor 1/8" = 1'-0" 3 03 Upper Level 1" = 10'-0" 4 East Elevation - COPY 1" = 10'-0" 5 North Elevation - COPY 1" = 10'-0" 6 South Elevation - COPY 1" = 10'-0" 7 West Elevation - COPY Area Schedule (16' Vaulted Area)NameAreaLevel 16' VAULTED AREA48 SF03 Upper Level48 SF Area Schedule (Garage Existing)NameAreaLevel GARAGE AREA537 SF01.0 Lower Floor537 SF Area Schedule (Living All) NameAreaLevelNEW LIVING AREA 2Not PlacedNot PlacedEXISTING LIVING AREA1143 SF01.0 Lower FloorEXISTING LIVING AREA 278 SF01.0 Lower FloorEXISTING LIVING AREA1892 SF02.0 Main FloorNEW LIVING AREA 128 SF02.0 Main FloorEXISTING LIVING AREA695 SF03 Upper LevelNEW LIVING AREA26 SF03 Upper Level3862 SF Area Schedule (Living Existing)NameAreaLevel EXISTING LIVING AREA1143 SF01.0 Lower FloorEXISTING LIVING AREA 278 SF01.0 Lower FloorEXISTING LIVING AREA1892 SF02.0 Main FloorEXISTING LIVING AREA695 SF03 Upper Level3808 SF Area Schedule (Living New) NameAreaLevelNEW LIVING AREA 2NotPlaced Not Placed NEW LIVING AREA 128 SF02.0 Main FloorNEW LIVING AREA26 SF03 Upper Level54 SF 1" = 20'-0" 8 02.0 Main Floor Area Schedule (Site Coverage)NameAreaSITE COVERAGE - EXISTING1892 SFSITE COVERAGE - NEW 215 SFSITE COVERAGE - NEW 128 SFGrand total: 31935 SF No.DescriptionDate 1Revision 1- V-ENGR 109.15.11 DN DN DN DN DW DN REF. DW REF. UP DN DN DN UP DN UP DN 1 A4.1 1 A4.2 2 A4.2 3 A4.2 NEW DECK AND RAILINGNEW DECK TO BE CUT AROUNDEXISTING ASPEN TREE NEW DECKAT THE SAMEELEVATIONAS EXISTINGDECK EXISTING DECK STRUCTURE WITH NEW DECKINGSURFACE AND NEW RAILING NEW RAILING 5 A4.2 8' - 8 1/4"7' - 4 13/16"5' - 6 5/8" 4 A4.2 11' - 6" 5 1/2"7' - 3 3/4" X 7'-6 " tall un it 3 panel sliding door w/ one operable panel 9' - 0" unit width1' - 8 1/2"11' - 0 1/2" 5 1/2" (3) 36" wide X20" tall operable units in transom 12' - 11 15/16"5 1/2"2' - 10 3/8"5 1/2" 1' - 3"8" X 9'-0" tall unit 4 panel sliding door w/ two operable center panels12' - 0" unit width 9" 4 1/2" 5' - 0" 1' - 8 1/4" EXISTING EDGEOF FLOOR CLAD COL. WITH WOOD TRIM7 1/2" x7 1/2". WALL BETWEENCOLUMNS. DOWN DRAFT HOOD, VENTTHRU GARAGE AND TOWEST EXTERIOR WALL 3' - 8 3/4"1' - 5"1' - 5" 1' - 10" 5 1/2" 6' - 1 1/2" 2' - 8" 3' - 10 1/2" 3' - 0" 6' - 0 7/8" existing opening 4' - 0 3/4" 3' - 6 1/4"8' - 2" FIREPLACE FLUE(2) 30x72 CLAD CASEMENT WDWSABOVE (2) 30x20 CLAD AWNING WDWSFIXED UNITS WITHIN 3'-0" OF FLUE Gas fireplace applianceHeat-N Glo 8000C(confirm with owner) ST tileWD ST tile WD ST tile cpt reuse existing door reuseexisting door 2' - 2" existing door existingdoor existing door existingdoor 6 1/2" 8" 1' - 2" ST tile WD UPPER PANTRYCABINETS TO EXTENDFROM COUNTER TOCEILING NEW IRON HANDRAIL 7' - 11 1/4" NEW BUILT-IN BOOKCASE/CABINET 32"x80" reuse existing32" linen bathdoor UP CLAD EXISTING BEAMWITH WOOD TRIMNEW COL. ONEX. GAR. BEAM DINING100 KIT 101 LIVING RM102 HALL103 ALCOVE104 BEDROOM105 CLO106 PWDR108 BEDROOM109 CLO110 BATH111 NEW BATH FAN.VENT TO THE EASTNEW POWDER ROOM TOILETAND SINK TO TIE INTOEXISTING WATER, WASTEAND VENTING PLUMBINGLINES REWORK EXISTING BASE BOARDHEAT AND ADD A 'SNAP-LOCK'RADIANT SYSTEM WITHIN THELIVING ROOM REWORK EXISTINGBASE BOARD HEATAND ADD A STAPLEUP RADIANTSYSTEM UNDERTHE FLOORSHEATHING OF THEDINING ROOM ANDKITCHEN NOTE:EXISTING BATH FANS IN BATH 111 ANDBATH 107 ARE TO REMAIN HOT TUB ELECTRICALDISCONNECT LOCATION 5' - 5 3/8" 2' - 7 1/4" 1 1/2" 2' - 7 1/4" ST tilecpt EXISTING TLTLOCATION. 2' - 2" 5 1/2" 5' - 6" 1' - 0" WOOD PANEL 2' - 8 1/2"BATH107 REMOVESOFFIT SM CO SMOKE DETECTORCO DETECTOR SMSM CO SM LEGENDexisting or newExisting detectors do notneed to be relocated 2' - 11" 3-panel folding door with 3 operable transom units8'-8" unit width 5 1/2" x 7'-6" tall unit 3- panel folding door8'-8" unit width 2' - 9" VERIFY CLEARANCE OFGUTTER AND KEEP DOORASSEMBLY AS FAR WESTAS POSSIBLE NEW COLUMNBELOW NEW COLUMNBELOW 16' - 1 3/16" 4' - 5"3' - 5 1/4" 2' - 8" 5' - 4" bath light switch 2 1/2" A5.11 oven 11' - 6" 14' - 0" 3' - 6"10' - 0" 2' - 6 3/4" 10' - 9"9' - 3"11' - 6" REUSEEXISTINGDOOR ATNEWPOWDERROOM REUSE EXISTINGDOOR AND JAMBAT NEWBEDROOMOPENING EXISTINGFIREPLACE, FLUE,AND STONEWORKIS TO BEREMOVED EXISTING BEAM TOBE CLEANED ANDPREPARED FORNEW STAINEDFINISH. OPTIONOF CLADDING INNEW MATERIALACCEPTABLE NEW MECH.FLUE TO RUNWITHIN STAIRWALL 8' - 0 3/4" 13' - 6" 16' - 6 1/2" 10' - 8 5/8" REMOVEDEXISTINGCHIMNEY 1 A4.1 1 A4.2 2 A4.2 5 A4.2 4 A4.2 NEW ENTRY DOORWITH SIDELITE Phase II(NOT IN CURRENT SCOPEOF WORK)ROSE SANDSTONE ISSEALED WITH A COLORTINTING SEALER TOREMOVE THEREDDISH/PINK COLORLAYOUT OF WASHERAND DRYER ANDCOUNTERTOPS ARETO BE REWORKEDWITHIN LAUNDRYROOMNEW IRON HANDRAILPhase II(NOT IN CURRENT SCOPEOF WORK)PORTION OF EXISTINGWALL TO BE CUT DOWNTO CURB HT AND A NEWGUARD RAIL TO MATCHEXISTING IS TO BEINSTALLED CLAD COL.WITH WOODTRIM7 1/2" x7 1/2". Phase II(NOT IN CURRENT SCOPE OFWORK)NEW CABINETRY CUBBIES ARETO BE CUT IN UNDER THEEXISTING STAIRCONSTRUCTION AND PROJECTINTO THE MECH ROOM 2'-0". 14' - 6"9' - 8" GARAGE001 ENTRY002 REWORK EXISTINGGARAGE DOOROPENING TOELIMINATE THEARCHED OPENING.REPAIR THE STONEWORK AS REQUIRED. REPAIR EXISTING STONE ASREQUIRED FOR NEW DOOR SIZE.REPAIR EXISTING CEILING FORDELETION OF SOFFIT OVER THEDOOR. SM CO SMOKE DETECTORCO DETECTORLEGENDexisting or newExisting detectors do notneed to be relocated SM SM SM CO NEW ENTRY DOOR WITHSIDELITES Phase II (NOT IN CURRENTSCOPE OF WORK)ROSE SANDSTONEIS SEALED WITH ACOLOR TINTINGSEALER TOREMOVE THEREDISH/PINK COLORPhase II(NOT IN CURRENTSCOPE OF WORK)PORTION OFEXISTING WALL TOBE CUT DOWN TOCURB HT AND ANEW GUARD RAILTO MATCHEXISTING IS TO BEINSTALLED 970 .328 .5151 O FF IC E PO B o x 1587 , E ag le , CO 81631 www .ma r tinman le ya rch ite cts .com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:22:07 AM 1481 Aspen Grove Lane Vail, CO 81657 A2.1 LOWER & MAIN PLANS & DEMO 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - 1/4" = 1'-0" 1 02 Main Floor - New 1/8" = 1'-0" 2 02 Main Floor Existing No.DescriptionDate 1Revision 1- V-ENGR 109.15.11 1/8" = 1'-0" 4 03 Upper Level - Existing 1/4" = 1'-0" 3 01 Lower Floor- New 1/8" = 1'-0" 5 01 Lower Floor Existing INSULATION VALUES/ENERGY CODENEW WALLS: R-23 BLOWN-IN INSULATIONNEW CANTILEVERED FLOORS: R-38 BLOW-INNEW ROOF STRUCTURE/CLG: R-49 BLOWN-INWINDOWS AND PATIO DOORS: U-VALUE .35GENERAL ELECTRICAL NOTETHE REVISION/RELAYOU T OF THE ELECTRICALAND LIGHTING WITHIN THE HOME SHALL BEINSTALLED WITHOUT THE ADDITION OFADDITIONAL CIRCUITS.THE NEW HOT TUB SHALL HAVE A DISCONNECTLOCATED AT THE SOUTH IF THE NEW DININGROOM WEST DOOR ASSEMBLY. DN 16' - 6" 13' - 6" 17' - 9"17' - 9" 1 A4.1 1 A4.2 2 A4.2 3 A4.2 5 A4.2 4 A4.2 AT ENTIRE ROOF- ALL EXISTING WOOD SHAKEROOFING IS TO BE REMOVED AND NEW METALSTANDING SEAM IS TO BE INSTALLED. NEWMETALL ROOFING ON FULL COVERAGE WATERPROOF MENBRANE ON ROOF SHEATHING ONINSULATED RAFTERS.REPAIR EXISTING ROOF SHEATHING ASREQUIRED.MAINTAIN EXISTING ROOF VENTIATIONALL NEW ROOF AREAS TO RECIEVE R-49INSULATION WITHIN THE CAVITY. REFER TOSECTIONS. 2" / 12" 2" / 12"8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12" 8" / 12" 8" / 12" 8" / 12" 8" / 12" 8" / 12" 8" / 12" SHADED AREAARE AREAS OFNEW ROOFSTRUCTUREORSTRUCTURETHAT IS BEINGREPLACED NEW SNOW FENCESNEW SNOW FENCE NEW SNOW FENCE 1 A4.1 1 A4.2 2 A4.2 OFFICE (3) 30x30 CLADAWNINGWINDOWS(HDR HT 7'-7 1/2"A.F.F.) NEW GLASSSHOWER NEW VANITY. COORDINATEWITH OWNER'S CABINETDESIGNER VERIFYLOCATION NEW OFPLUMBING LIGHT SHELF 3 A4.2 5 A4.2 4 A4.2 1' - 3"4' - 3 1/2"3' - 1"7' - 0 1/2"12' - 0"5'-5". 5' - 3" 2' - 1"3' - 3"2' - 6"2' - 6"2' - 1" 5' - 10 1/2" 2' - 0 5/8" 4' - 5" 2' - 0"EQ 2'-6". EQ 5'-11". 2' - 7 1/4"12' - 5"(1) 30x30 CLADAWNINGWINDOWS(HDR HT 7'-7 1/2"A.F.F.) reuseexisting door reuseexisting door REUSE (2) 2'-0"x7'-0"CLOSET DOORS ONBARN DOOR TRACK. EXISTING WINDOWSEXISTING WINDOWS EXISTING WINDOWS MASTER BEDROOM201 OFFICE202 CLOSET203M.BATH204 WC205 REWORK EXISTINGBASE BOARDHEATER TO BE AEUROPEAN STYLERADIATOR NOTE:BATH FAN IN BATH 205SM CO SMOKE DETECTORCO DETECTORLEGENDexisting or newExisting detectors do notneed to be relocated SM SM CO COORDINATE FLAT CEILING HEIGHT WITH ARCH. OWNER NEW TUB 1' - 1 1/2" 5' - 0" 2' - 6"10" 970 .328 .5151 O FF IC E PO B o x 1587 , E ag le , CO 81631 www .ma r tinman le ya rch ite cts .com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:22:24 AM 1481 Aspen Grove Lane Vail, CO 81657 A2.2 UPPER AND ROOF PLAN 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - 1/4" = 1'-0" 1 04 Roof Plan - New No.DescriptionDate 1Revision 1- V-ENGR 109.15.11 2 EXT - NORTH DECK - LOOKING SOUTH 4 EXT - FRONT ELEVATION- LOOKINGNORTH 5 FRONT ISOMETRIC 6 REAR ISOMETRIC 1/4" = 1'-0" 3 03 Upper Level - New 02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6" 8' - 0"9' - 0"9' - 0" 26' - 0" 1 A4.2 33' - 0" 8463' - 6" 8429' - 6" MAXIMUM HEIGHT NOT TO EXCEED NEW BALCONY RAILING:AUSTRIAN STYLE 8" 12" 2" 12" NEW LIVING ROOMWINDOWS / DOORS NEW ENTRY DOOR / SIDELITENOTE - RIDGE ELEVATIONSSEE "PEAK LAND CONSULTANTS" SURVEYDATED 4-13-11 5 A4.2 REMOVE CHIMNEYNEW SHED ROOF 8447' - 7" CONFIRM CLEARANCESFOR NEW FIREPLACEDIRECT VENT FLUE NEW NEW EXISTINGDININGWINDOWREUSED(ARCHED TOPWINDOWREMOVED) EXISTING EXISTING EXISTING EXISTING REPAIR EXISTING FINISHESAROUND NEW DOOR ANDWINDOW LOCATIONS EXISTING GARAGE DOOR TO BECLAD WITH NEW TRIMSTONE AT REMOVED ARCH TOPSTONE IS TO BE REPAIREDUSING EXISTING STONE NEW SHED ROOFFASCIA TO MATCH EXISTING TIMBER OUTLOOKER SNOW FENCE 8' - 0" 3' - 3" 5' - 11 3/4"NEW3' - 6" 02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6" 1 A4.1 2 A4.2 3 A4.2 MASTER BATH DORMERNEW SHED ROOFNEW WALL / WINDOWSDINING ROOM ROOFNEW SHED ROOFNEW WALL / WINDOWS EXISTING CHIMNEY(REMOVED) NEW METAL ROOF:STANDING SEAMRust COLORNEW RAILINGAUSTRIAN STYLE NEW DINING ROOM WINDOWS(RE-USE DEMO WQINDOW AT BATH) 4 A4.2 2" / 12"2" / 12" NEW SNOW FENCES NEW SNOW FENCES 14'-0". 970 .328 .5151 O FF IC E PO B o x 1587 , E ag le , CO 81631 www .ma r tinman le ya rch ite cts .com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:22:40 AM 1481 Aspen Grove Lane Vail, CO 81657 A3.1 E x te r io r E leva t ion s 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - 1/4" = 1'-0" 2 South Elevation - NEW 1/4" = 1'-0" 1 West Elevation - NEW 1/8" = 1'-0" 3 South Elevation - EXISTING 1/8" = 1'-0" 4 West Elevation EXISTING No.DescriptionDate 1Revision 1- V-ENGR 109.15.11 02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6" EXISTING ROOF/WALL / WINDOWSSIDING & TRIM 02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6"9' - 0"9' - 0"8' - 0" 1 A4.2 2" 12" 2" 12" NEW NEW NEW DBL FASCIA(MATCH EXISTING)NEW SIDING /TRIM(MATCH EXISTING)NEW STUCCO(MATCH EXISTING) NEW SIDING /TRIM(MATCH EXISTING) 5 A4.2 8448' - 8 1/2"BTM OF HDR EXISTING EXISTINGEXISTINGEXISTING DOOR HEADSTO ALIGN 3 1/2"1' - 11"2 1/2"3"2" 7 1/2" 3 13/16" 2' - 11 13/16" 7 1/2"5 1/2" 7/8" 4 1/4" picket spacing.(<4" clear opening between) 970 .328 .5151 O FF IC E PO B o x 1587 , E ag le , CO 81631 www .ma r tinman le ya rch ite cts .com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:22:56 AM 1481 Aspen Grove Lane Vail, CO 81657 A3.2 E x te r io r E leva t ion s 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - 1/4" = 1'-0" 2 East Elevation - NEW 1/4" = 1'-0" 1 North Elevation - NEW 1/8" = 1'-0" 3 East Elevation -EXISTING 1/8" = 1'-0" 4 North Elevation -EXISTING No.DescriptionDate 1Revision 1- V-ENGR 109.15.11 1" = 1'-0" 5 mtl picket Deckrailing detail 02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6" 1 A4.2 5' - 0"3' - 9 3/4" NEW 30x30 CLAD AWNING WINDOWSNEW SHED ROOF WITH STANDING SEAMROOFING ON FULL COVERAGEWATERPROOF MEMBRANE ON ROOFSHEATHING ON 2x ROOF RAFTERS.INSULATE THE ROOF STRUCTURE WITHBLOWN-IN INSULATION (R-49) NEW SHED ROOF EXISTING BEAMCLAD WITH MEW WOOD TRIM.PROVIDE MARINE POLY. COAT DUETO WET LOCATION OFSHOWER/BATHROOM 5 A4.2 2" / 12" 2" / 12" 8' - 9 3/4" 5 1/2" PROVIDE NEW FLAT CEILING AT SPRING POINT.INSULATE THE ROOF STRUCTURE AND CAVITY WITH BLOWN-ININSULATION (R-49) MATCH EXISTING ROOF FASCIA DETAIL OVERHANG1' - 11 5/8" 8456' - 1 1/2"BTM OF HDR 7' - 7 1/2" 8449' - 7 3/4" 10' - 1 3/4" 8457' - 3 3/4"PLATE HT PLATE HT 1' - 11 5/8" MATCH EXISTING ROOF FASCIA DETAIL 11 1/4" 9' - 2 1/2"11 1/4" PROVIDE SLOPE ONLIGHT SHELF TILEDSURFACE FORDRAINAGE 12' - 0 3/4" BLOWN-ININSUALTION R-23PROVIDE WALL TO ROOFFLASHING AND COUNTERFLASHING. FULLY COVERSIDE WALLS WITH FLASHING 8448' - 8 1/2"BTM OF HDR 6" NEW STONE TILE FLOORINGIN KITCHEN AND DINING COORDINATE DESKSTRUCTURE TO SPAN OVEREXISTING SHED ROOF EXISTING BEAM TO BE CLEANEDAND PREPARED FOR NEW FINISHOR CLAD WITH NEW WOOD TRIM CLAD COL. WITH WOOD TRIM 7 1/2" x7 1/2".PROVIDE SHELVING BETWEEN COLUMNS.CONFIRM SPACING WITH OWNER 10' - 0" NEW DROPPED CLGCOORDINATE HT WITHARCHITECT OR OWNERBEFORE FRAMINGNEW SHOWER CURBAND PAN. CONNECTDRAIN TO EXISTINGPIPINGPHASE IIROSE SANDSTONG IS TOBE REPLCED WITHCOLORADO BUFFCOLOORED SANDSTONE.(CAUTION: THERE IS HEATPIPING WITHIN THE MOTARBED OF THE EXISTINGSTONE)PHASE IIPORTION OF EXISTINGWALL TO BE CUT DOWNTO CURB HT AND A NEWGUARD RAIL TO MATCHEXISTING IS TO BEINSTALLED PHASE IINEW CABINETRY CUBBIESARE TO BE CUT IN UNDERTHE EXISTING STAIRCONSTRUCTION ANDPROJECT INTO THE MECHROOM 2'-0". KIT 101 DINING100 HALL103 BEDROOM105 GARAGE001 ENTRY002 M.BATH204 A5.12 A5.14 970 .328 .5151 O FF IC E PO B o x 1587 , E ag le , CO 81631 www .ma r tinman le ya rch ite cts .com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:22:58 AM 1481 Aspen Grove Lane Vail, CO 81657 A4.1 LARGE SCALE BLDG SECT ION 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - No.DescriptionDate 1Revision 1- V-ENGR 109.15.11 1/2" = 1'-0" 1 LARGE SCALE BUILDING SECTION 02.0 Main Floor8439' - 6"03 Upper Level8448' - 6" 1 A4.1 2 A4.2 4 A4.2 6" NEW STEPS LIVING RM102 DINING100 02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6" 1 A4.2 NEWWINDOWS ANDDOORS 3' - 0"16' - 0" 5 A4.2 1' - 0" THIN STONE2 1/2" 1' - 4" 8" THIN STONE2 1/2" 4" 7 13/16"1' - 2" 2' - 0" 12"x6" TIMBER Gas fireplace applianceHeat-N Glo 8000C(confirm with owner) FIREPLACE VENT.PROVIDE PROPERCLEARANCES AND 1HOUR RATED CHASETO EXTERIOR LIVING RM102 MASTER BEDROOM201 GARAGE001CLAD EXISTING BEAMWITH WOOD TRIM EXISTING WALLCONSTRUCTION.REMOVED EXISTINGSOFFIT ABOVE THATVANITY AND TLT OFFICE202 8' - 0" 02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"01.0 Lower Floor8430' - 6"03 Upper Level8448' - 6" 1 A4.2 8449' - 7 3/4" LIVING RM102CLOSET203 GARAGE001 NEW SHED ROOF WITHSTANDING SEAM ROOFINGON FULL COVERAGEWATERPROOF MEMBRANEON ROOF SHEATHING ON 2xROOF RAFTERS. INSULATETHE ROOF STRUCTURE WITHBLOWN-IN INSULATION (R-49)PLATE HTNEW WALLCONSTRUCTION ANDEXTENED FLOORCONSTRUCTION.PROVIDE BLOWN-ININSUALTION R-23 ATWALL AND R-49 INFLOOR. CLAD EXISTINGBEAM WITHWOOD TRIM NEWCABINETWITHINWALL VOID CLAD COL. WITH WOODTRIM 7 1/2" x7 1/2".PROVIDE SHELVINGBETWEEN COLUMNS.CONFIRM SPACING WITHOWNERCLAD NEW BEAM MATCH EXISTING ROOFFASCIA DETAIL AND WALLSIDING FLASHING PROVIDENEWDROPPEDCLG AT CLO CLOSET ROD,SHELVING ANDPANT HANGINGSYSTEM TO BEDESIGNED ANDAPPROVED BYTHE OWNR 02.0 Main Floor8439' - 6"04 Roof Plate8456' - 6"03 Upper Level8448' - 6" 4' - 0" 8' - 0" CLAD COL. WITH WOOD TRIM 71/2" x7 1/2". PROVIDE SHELVINGBETWEEN COLUMNS. CONFIRMSPACING WITH OWNER WOODPANELING 970 .328 .5151 O FF IC E PO B o x 1587 , E ag le , CO 81631 www .ma r tinman le ya rch ite cts .com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:23:01 AM 1481 Aspen Grove Lane Vail, CO 81657 A4.2 SECTIONS 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - No.DescriptionDate 1Revision 1- V-ENGR 109.15.11 1/4" = 1'-0" 1 SECTION THRU LIVING AND DININGLOOKING WEST 1/4" = 1'-0" 2 SECTION THRU LIVING ROOM ANDFIREPLACE 1/4" = 1'-0" 3 SECTION THRU BATH 107 1/4" = 1'-0" 4 SECTION THRU LIVING LOOKING NORTH 1/4" = 1'-0" 5 LIVING ROOM - FIREPLACE DN DW DN REF. DW REF. 2 1/2" 30" built-in sub zero 2' - 6"3/4"2' - 7 1/2" BC 7 1/2" Wolf Dbl OVEN DO30-2U/S 2' - 6"3" doubleoven END PANEL 2' - 0" Wolf 36" Ind CT36 w/ DB 3' - 0" SPICE 1' - 0"3' - 0" DB 9 1/2" 2 1/2" SINK BASE3' - 0" 2 1/2" DISHWASHER2' - 0" 1 1/2" 2' - 4 3/4"2 5/8" CB 2' - 9" DB 2' - 9" DB 2' - 9" CB 2' - 9" 3' - 1 3/4" 1 1/2" 1 1/2"3 1/2" 1/2" 2' - 0"1" 8' - 10 3/4"5' - 6 1/2" 2' - 0" 4' - 0" END PANEL2' - 0" DB 1' - 2" DB short1' - 2" END PANEL2' - 0" DOWN DRAFT CHASE OUTLETON SIDE OUTLETON SIDE OUTLETBACK OFCAB FORGB AND DWGD BATCHFEED SWITCH PLUG MOLDOUTLET INSIDE(ABOVECOUNTER) (3) SWITCHES INSIDE PANEL DB 2' - 0" DB 2' - 0" END PANEL 2' - 0" OUTLET ON SIDE 6' - 4" 6' - 0" 3' - 1 3/4" 3' - 0" 3" 2' - 6" 7 1/2" 2' - 0" 7 1/2" 3/4" 2' - 6"2 1/2" 1 1/2" ref coordinateclosure trim panel Sub-Ze ro BI 30UG w/ gls d r 7' - 0"6" 3' - 3" Sharp micro Wolf dbl ovenDO30-2U/S 1' - 3 1/2"4' - 2"1' - 9" 5' - 9" 9 1/2" 2 1/2" 3' - 0" 2 1/2" 2' - 0" 1 1/2" dishwasher switches end panel2' - 0" cook top and DB3' - 0" spice 1' - 0" end panel2' - 0" DB 1' - 2" DB short1' - 2" end panel2' - 0" DB 2' - 0" DB 2' - 0" end panel2' - 0" 970 .328 .5151 O FF IC E PO B o x 1587 , E ag le , CO 81631 www .ma r tinman le ya rch ite cts .com P ro je ct num ber D ateR EV IS IONS 9/26/2011 8:24:18 AM 1481 Aspen Grove Lane Vail, CO 81657 A5.1 KITCHEN DE TAILS 1105Suszynski Renovation REVISED PERMIT SET 9-15 -11 - No.DescriptionDate 1/2" = 1'-0" 1 KITCHEN PLAN of 02 Main Floor - New 1/2" = 1'-0" 2 BAR CABINETRY 1/2" = 1'-0" 3 EAST KITCHEN CABINETRY 1/2" = 1'-0" 4 SOUTH SIDE OF ISLAND CABINTRY 1/2" = 1'-0" 5 EAST SIDE OF ISLAND CABINETRY 1/2" = 1'-0" 6 NORTH SIDE OF ISLAND CABINETRY 1/2" = 1'-0" 7 WEST SIDE OF ISLAND CABINETRY8 3D View 1 9 Copy of INT - DR - LOOKING TOWARDKITCHEN 10 3D View 6