HomeMy WebLinkAboutB11-0389NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MIA OF
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B11 -0389
Project #:
Job Address: 390 S FRONTAGE RD W VAIL
Location......: 390 S FRONTAGE RD W- TRANSIT CENTER
Parcel No....: 210106407012
OWNER TOWN OF VAIL 10/03/201'
C/O FINANCE DEPT
75 S FRONTAGE RD
VAIL
CO 81657
APPLICANT ACTIVE ENERGIES SOLAR, LLC
PO BOX 7627
AVON
CO 81620
License: C000003295
CONTRACTOR ACTIVE ENERGIES SOLAR, LL(
PO BOX 7627
AVON
CO 81620
License: C000003295
10/03/2011 Phone: 970-306-4233
10/03/2011 Phone: 970-306-4233
Description:
FLUSH MOUNTED PV SYSTEM FOR TRANSIT CENTER
Occupancy: A -3 Type Construction: VB
Applied.....:
Issued...
PRJ 10 -0346
10/03/2011
10/28/2011
Valuation: $29,123.00
.. ............................... ................ ...............................
FEE SUMMARY ...... .......�,...................... <.... ...........�......,........,...
Building Permit ------ - - - - ->
$441.75
Bldg Plan Check ----- - - - - -> $287.14
Use Tax Fee------------------ - - - - ->
$382.46
Electrical Permit ---- - - - - ->
$0.00
Elec Plan Check ------ - - - - -> $0.00
Restuarant Plan Review--- - - - - ->
$0.00
Mechanical Permit - - - - - ->
$0.00
Mech Plan Check ---- - - -
- -> $0.00
Additional Fees--------------- - - - - ->
($116.35)
Plumbing Permit --- - - - - ->
$0.00
Plmb Plan Check ---- - - - - -> $0.00
Recreation Fee--------------- - - - - ->
$0.00
Investigation------------------ - - - - ->
$0.00
Will Call ------------------------------ >
$5.00
TOTAL PERMIT FEES -- ----------- >
$1,000.00
Payments -- ---------------------------- >
$1,000.00
BALANCE DUE------------------ - - - - ->
$0.00
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
8:00 AM - 4
FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
Signature of '-b' ontractor
Print Name
Date
combination permit_012811
MwNoFV�
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: B11 -0389
Owner: TOWN OF VAIL
FRONTAGE RD W- TRANSIT CENTER
Address: 390 S FRONTAGE RD W VAIL
Location: 390 S
combination permit_012811
O V�AIL
iu
,rw *r ** • trw*** r t*, t r*****r* t+ x**, r*, r****, r****+ r, r**, r, r*, r, rw*** tr*, r***, r*, r * *,r *rr * * * * *r *,r * *,r,r,r * * * * * ** r*** trr* rtrrr*, r* arxr, r*, r, r, rw*** r, r, rr, r, rrr, t* *,r * *t+r * *,r,r,r *,r *,r,r,r * * * **
REQUIRED INSPECTIONS AND STATUSES
Permit #: B11 -0389
Owner: TOWN OF VAIL
FRONTAGE RD W- TRANSIT CENTER
Address: 390 S FRONTAGE RD W VAIL
Location: 390 S
Item:
00120 ELEC -Rough
Item:
00130 ELEC- Conduit
Item:
00190 ELEC -Final
Item:
00542 PLAN -FINAL
Item:
00090 BLDG -Final
combination permit_012811
TOWN OF VAIL, COLORADO Statement
Statement Number: R110001572 Amount: $1,000.00 10/28/201108:55 AM
Payment Method: Check Init: SAB
Notation: 1572 - ACTIVE
ENERGIES
-----------------------------------------------------------------------------
Permit No: Bll -0389 Type: COMBINATION BLDG PERMIT
Parcel No: 2101 - 064 - 0701 -2
Site Address: 390 S FRONTAGE RD W VAIL
Location: 390 S FRONTAGE RD W- TRANSIT CENTER
Total Fees: $1,000.00
This Payment: $1,000.00 Total ALL Pmts: $1,000.00
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
00100003111100, GFPO ELEC PERMIT FEES- GFP012 1,000.00
TOWN OF VAN.'
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970 -479 -2128
www.vailgov.com
Development Review Coordinator
SOLAR THERMAL /PHOTOVOLTAIC PERMIT APPLICATION
(Separate applications are required for a new electrical panel or any roof alteration)
Project Street Address:
395 East Lionshead Circle
(Number) (Street) (Suite #)
Building /Complex Name: ToV Lionshead Transit•
Contractor Information
Active Energies Solar LLC
Project #:
-ek 11 I — 1�3y
DRB #:
U6 jlJ�lp3
Permit #:
Lot #:
Block # Subdivision:
Business Name.
PO Box 7627
Work Class: New ( ✓) Addition ( ) Alteration ( )
Business Address:
City Avon CO 81620
Zip: p:
Type of Building:
Single- Family ( ) Duplex( ) Multi- Family ( )
Jason Wein ast
Contact Name: g
Commercial ( ✓) Other ( )
Contact Phone: 970 - 306 -4233
Contact E -Mail: j ason@activeenerg ies.com
9
Work Type: Interior ( ) Exterior ( ) Both ( ✓ )
-
_... -__ ..
X
Solar Type:.
Owner /Owner's Representative Signature (Required)
Photovoltaic ( ✓) Solar Thermal ( )
Applicant Information
- -- -
flk_C4 -6y- � L AZ S
Applicant Name: Jason Weingast
n
Applicant Phone: 970- 306 -4233
Applicant E -Mail: Jason @activeenergies.com
Project Information Town of Vail
Owner Name:
Parcel #:
Value of all work being performed: $ 29.
(For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit
—.eaglecounty.us/patte)
(value based on IBC Section 109.3 8 IRC Section 108.3)
Detailed Scope and Location of Work: DC side of 5.55kW flush mounted PV system
(use additional sheet if necessary)
For Office Use Only:
Fee Paid:
Received From:
Cash Check #
CC: Visa / MC Last 4 CC # exp date:
Auth #
Date
D
SEP 3 0 2011
TOWN OF VAIL
IS -Jul -11
I
O
K
J
N
J
a
C
O
O
n
00
T
N
O
b
O
N
N
J
0
N
J
N
O
w
O
0 o
ON
W%
IN
0
R
D
.A
L
e u
�
m - 6
r�
J
a �
0
n (n
I d Z
n �
Q w v
- a m
...............
..a vw
OFFICE . COPY
d
m
n�
� m
m
a
D
3
c
n
0
0
--i
w D <
<
M
d N (n
rm
00 n
w s +
� d �
4
n C7
() N
(D
9 1
m
K cn
d C71
N < c C71
ID
N 7�
o m m v -° °� m w C
p_ D x x (p m= :. o c.
O d d wo u)
'� C N 3 7 0 'T,
N < C
o D $ m (o (o a (� o
� -��' (o � (7 < vt v i i oo CCD
o
V C C C C . y A II n
N p N o m w (.Ail --I
(n N CD n 3 m o D< v <
0o rn .. `° `r m
3 W N ( A (D O
D< D< y o p
m n
Q n
K
a � m
n m
0 Z - g F
m d < x
rn 9: m m
j��L
o�
o m
• ,ak
i'l w r
c
/W►
kwo
i
OJ N O _ O • -9 U ' o ' - '
O ' D
O O N N
' A(Dy S
N O G< 7 N7 (
S <O m ON
E' (D
c [n D w
w o
m nv
c
n
�o < +m m
m m u� oo m° o'
,
m
Na 0 (D
(D Z7 O �' O. N
m
O
/
D� cn
m o m
o o Z
C
cnmm �'
m C7 m rn r m
�. rn a o n
N N- a
O d N
n (O -1 O
(D O (p
,C..
v °mw>
W CD m
c
m
o
D
oC P
n
M o
c o u
O n>
> m
..a vw
OFFICE . COPY
d
m
n�
� m
m
a
D
3
c
n
0
0
--i
w D <
<
M
d N (n
rm
00 n
w s +
� d �
4
n C7
() N
(D
9 1
m
K cn
d C71
N < c C71
ID
N 7�
o m m v -° °� m w C
p_ D x x (p m= :. o c.
O d d wo u)
'� C N 3 7 0 'T,
N < C
o D $ m (o (o a (� o
� -��' (o � (7 < vt v i i oo CCD
o
V C C C C . y A II n
N p N o m w (.Ail --I
(n N CD n 3 m o D< v <
0o rn .. `° `r m
3 W N ( A (D O
D< D< y o p
m n
Q n
K
a � m
n m
0 Z - g F
m d < x
rn 9: m m
j��L
o�
o m
• ,ak
i'l w r
c
/W►
kwo
i
A - rivi..
ENF,I?( #IH
5.55kW System Size (STC)
CALCULATIONS
30 Suntech STP 1855- 24 /Adb+ black solar panels @ 185watts
30 Enphase M -190 micro - inverters 208v — 2 branches of 15/15 units
Fixed array tilt angle: 22.6°
Array azimuth: 180° (where 180° is south)
Estimated annual power production: 7,975kWh
Mounting Feet: DPW Easy Power Posts
Mounting Rail: Direct Power and Water's Power Rail P8 - Extrusion
Maximum PV System Voltage: 690.7
Voc = 45V /module
45V x 1 module = 45V
Temperature correction factor 690.7(A)
STC = 25 °C, Temperature Coefficient (Voc) _ - 0.34 % / °C
(25 °C - -40 °C) _ -65 °C
45V x ( -65 °C x (- .34 % / °C) x 1 module) + 45V = 55V
Temperature correction factor Table 690.7
For -40 °F use 1.25
45V x 1.25 = 56.3V
Maximum PV Source Circuit (String) Current:
I = 5.43A
5.43A x 1.25 = 6.8A
Maximum PV Output Circuit (Array) Current:
Qj 1 strings = 6.8A
Invertei u Cirt Ctirrent:
ZQ�A- a 208V
John Wiles, " ot oAZc Power Systems and the National Electrical Code: Suggested
Practices ", 20 El
690.8 (A)(1)
690.8 (A)(2)
690.8 (A)(3)
pdf version -,&li e atp http:/ /Nvww nmsu.edu/%7Etdi/Photovoltaics/Codes-
Stds /PVnecSuQPract.html
P age 2 of 4 9/26/2011
P,0, Box 1627, Avm 00 216201 P. 970.227.0272 i "G3.330.=0 ( F. 26640334-5 `! C x;-arw.wt veeurrg es.cazn
C
K
Z
Acvivi
E.N .12t =IFs
SOT .1lt sX-
CONDUCTOR SIZING
Pass Thru Box to AC Disconnect /Panel (for a 15 panel circuit):
Nameplate maximum continuous output current:
.92A
Maximum Output Power 190 Watts AC
190 W _ 208 V =.92A
.92A x 5 inverters per phase = 4.6A per phase per branch
4.6A x 1.73 = 8A per leg
8A x 125% = 10A
#10 THWN -2 Table 310.16
30A (90 °C column, see note 240.4(D))
Conduit fill adjustment
No Conduit Fill Adjustment
Temperature correction factor
No Temperature Correction
Overcurrent Protection Device per circuit
2 - 15A three pole breakers
-°t
O W C)
0
6
M
Table 310.15 (13)(2)(a)
Table 310.16
Per Manufacturer Specification
Alk
/ ! / ! e
L
z
(
P age 3 of 4 9/26/2011
P.0, Boz "%27, Avmi fC0.8I62a I P: 97,0 - 7 M72 t 303.330.Sd0 J F: 266.4033425 1 wwwrsLwener ies com
ArOWER -FAB
Peel off
protective
Paper
Easy Post
(bottom
of base)
Butyl
Mastic
Figure 1: Removing Protective Paper
�1/4x1'/z"
RSS PHEinox
Screw (6 places)
�
Neoprene
Bonded
Washer
(rubber side
down)
4 "_
15/16"
4"
Easy Post 1 /s "�
(press firmly
onto Roof � �f-- 4 " —+1 --f
Substrate)
CD
CAD,
,.
Fi_qure 2: Securing
Easy Post Installation Guidelines
Post to Roof
Field locate center holes
directly over LVL below.
Version 1, RevA
PCN 072210 -1
/ , * Other heights available
3�1 -o3�s
F,I:t;II. :S
SMIAR
SOLAR INSTALLATION INFORMATION
Vendor: Active Energies Solar LLC
PO Box 7627
Avon, CO 81620
(970- 306 -423 3 /info @activeenergies. com)
Site: ToV Lionshead Transit Center
395 East Lionshead Circle
Vail, CO 81657
MARTIN/MARTIN, INC.
REVIEWED FOR GENERAL ARRANGEMENT.
REVIEW SUBJECT TO COMPLIANCE WITH ALL
CONTRACT REQUIREMENTS. DETAILED
DIMENSIONS AND QUANTITIES NOT CHECKED.
EXCEPTIONS AS NOTED
Date Received 09/26/2011
Reviewer: ERS
Date Returned: 0926/2011
All AC wiring to be completed by a Colorado licensed master electrician—. _
All DC wiring to be overseen by NABCEP certified installer T-
Photovoltaic AC Disconnects located adjacent to the main service panel and meter.
Minimum Designed Temperature: -40QF
Maximum Ambient Design Temperature: 140QF
Panel Arrangement:
O
CD �
C
r GQ
rn
m ,n
X
0
Not to scale
P age 1 of 4 ' 1 a 9/26/2011
P.O Rcs "x627, Avaa; 00 21620 1 P; 470.22 ?.0272 1303.330.4 0 1 F 266.4033425 1 www,ec6veanergieszom
l
MICRO - INVERTER TECHNICAL DATA
Input Data (DQ
M190 -72- 208 -511/2
M190 -72- 240 -511/2
Recommended input power (STC)
230W
230W
Maximum input DC voltage
54V
54V
Peak power tracking voltage
22V — 40V
22V — 40V
Max. DC short circuit current
12A
12A
Max. input current
10A
10A
Output Data (AQ
Maximum output power
190W
190W
Nominal output current
920mA
800mA
Nominal voltage /range
208W1 83V-229V
240V/211V -264V
Extended voltage /range
208V/179V -232V
240W206V -269V
Nominal frequency /range
60.0/59.3 -60.5
60.0/59.3 -60.5
Extended frequency /range
60.0/59.2 -60.6
60.0/59.2 -60.6
Power factor
>0.95
>0.95
Maximum units per branch
21
15
Efficiency
Peak inverter efficiency
95.5%
95.5%
CEC weighted efficiency
95.0%
95.0%
Nominal MPP tracking
99.6%
99.6%
Mechanical Data
Operating temperature range -40 °C to +65 °C -40 °C to +65 °C
Night time power consumption 30mW 30mW
Dimensions (WxHxD) 8" x 5.25" x 1.25"
Weight 4.4 Ibs
Cooling Natural Convection — No Fans
Enclosure environmental rating Outdoor— NEMA 6
Features
Communication Powerline 13
Warranty 15 Years ' { i
Compliance UL1741 /IEEE1547 �
FCC Part 15 Class B AM
Enphase Energy Inc. 142 -00005 REV 02
u
201 1st Street, Suite 300, Petaluma, CA 94952 9 ph
877 797 4743 enphaseenergy.com ® Printed on 100 percent recycled paper. vi
N4
M
OdHI NI =1-40 WHaL IHOHS
4 ";;p
5 - SIN3K3A021dWINOLL03Sd31N1)3j51E)dHI82Li51013 -
WS NO ONIGIM on oNv skve sna oo3 -
�131N30 iISN�Ji OV3HSN0I
M11- wl-
um
III
I
I I
ICI
MIM
0
IL
O
X
HUI
co
CD
I II
x
UJ
0
CL
CD
Lo
(D >
as
CD
rq
A
cz
c0
a) CL (D
co
(D
LQ
LL
0
CD
cz
M11- wl-
um
III
I I
ICI
um
J SUN TECH
Solar powering a green future"
185 Watt
MONOCRYSTALLINE SOLAR MODULE
Suntech Black LabelTM modules are exclusively
designed and engineered for homeowners who seek a
rooftop solar solution that combines visual aesthetics
with excellent efficiency.
Features
High module conversion efficiency (up to 14.5 %),
through superior manufacturing technology
Guaranteed 0 -5W positive power output tolerance
ensures high reliability
Proprietary Gallium -F22 doping process
dramatically reduces initial light- induced
degradation to <1 %, thus delivering better power
and performance over time
Entire module certified to withstand high wind
,,. loads (2400 Pascal) and snow loads (5400 Pascal)
Trust Suntech to Deliver Reliable Performance Over Time
• World's leading manufacturer of crystalline silicon photovoltaic modules
• Unrivaled manufacturing capacity and world -class technology
• Rigorous quality control meeting the highest international standards:
ISO 9001: 2008 and 150 14001: 2004
• Certification and standards: IEC 61215, IEC 61730, conformity to CE
Industry - leading warranty
SUNTECH
g
n
25 year transferrable power output warranty:
5 year /95 %, 12 year /90%, 18 year /85 %, 25
year /80% **
Based on nominal power
Warrants 6.7% more power than the market
standard over 25 years
5 year material and workmanship warranty
* Please refer to Suntech Standard Module Installation Manual for details.
**Please refer to Suntech Product Warranty for details.
Patented surface pyramids
enhance sunlight absorption
by redirecting reflected light
to other areas on the cell
t
surface to be reabsorbed
z
7.
Suntech cells feature a
breakthrough process that
ee
replaces traditional boron
doping with gallium doping.
The effect of initial light - induced ,
degradation is dramatically
reduced, leading to greater
power output over the entire
module lifetime.
Graph is for illustration only and does not imply any guarantee of module
performance. Please check warranty for details.
@Copyright 2010 Suntech Power
®TCEc°.uS
DrW-, halny
""Il
e pYaE
AL
2 pl 100 2�✓
' z G pacas
Section A -A
I
Note: mm (inch)
Current - Voltage & Power - Voltage Curve (1855 -24)
u'
voltage M
= I- = --I- cao- _ Sao- = mo-
Temperature Characteristics
zoo
lao
1�
Iw _
Izo 3
IN 3
eo u
m
Nominal Operating Cell Temperature (NOCT)
4512 °C
Temperature Coefficient of Pmax
-0.48 %/°C
Temperature Coefficient of Voc
(Back View)
Temperature Coefficient of Isc
0.037 %/°C
_i_
= e3�eeee
e_e_ ==ee
Maximum Power at STC (Pmax)
185 W
180 W
Module Efficiency
14.5 %
14.1%
Current - Voltage & Power - Voltage Curve (1855 -24)
u'
voltage M
= I- = --I- cao- _ Sao- = mo-
Temperature Characteristics
zoo
lao
1�
Iw _
Izo 3
IN 3
eo u
m
Nominal Operating Cell Temperature (NOCT)
4512 °C
Temperature Coefficient of Pmax
-0.48 %/°C
Temperature Coefficient of Voc
-0.34 %/°C
Temperature Coefficient of Isc
0.037 %/°C
Dealer information box
Electrical Characteristics
Optimum Operating Voltage (Vmp) 36.4 V
36.0 V
Optimum Operating Current (Imp)
5.09 A
5.00 A
Open - Circuit Voltage (Voc)
45.0 V
44.8 V
Short - Circuit Current (Isc)
5.43 A
5.29 A
Maximum Power at STC (Pmax)
185 W
180 W
Module Efficiency
14.5 %
14.1%
Operating Temperature
-40 °C to +85 °C
-40 ° C to +85 ° C
Maximum System Voltage
600 V DC
600 V DC
Maximum Series Fuse Rating
15A
15A
Power Tolerance
045 W
0/ +5 W
STC: Irradiance 1000 W /mz, module temperature 25 °C, AM =1 S
unrr crosoee �nrna� cro�one_�n iad�
Maximum Power (W)
137W
133 W
Maximum Power Voltage (V)
33.2 V
32.9 V
Maximum Power Current (A)
4.11 A
4.05 A
Open Circuit Voltage (Voc)
41.3 V
40.9 V
Short Circuit Current (Isc)
4.39 A
4.30 A
Efficiency Reduction
(from 1000 W /m' to 200 W /m')
<4.5%
<4.5%
NOCT: Irradiance 800 W /m', ambient temperature 20 °C, wind speed 1 m/s
Mechanical Characteristics
Solar Cell
Monocrystalline 125 x 125 mm (5 inches)
No. of Cells
......... ...
...............................
72 (6 x 12)
.. ..
Dimensions
1 26
1580 x 808 x 35mm (62.2 x 31.8 x 1.4 Inches)
Weight
12
15.5 kgs (34.1 lbs.)
Front Glass
I 312
3.2 mm (0.13 inches) tempered glass
Frame
.......... .. .
Anodized aluminium alloy
Junction Box
IP67 rated
H +S RADOX" SMART cable 4.0 mm' (0.006 Inches'),
Output Cables
symmetrical lengths ( -) 1000 mm (39.4 inches) and
( +) 1000 mm (39.4 inches), H4 connectors (MC4
compatible)
Packing Configuration
Container
20' GP
40' GP
Pieces per pallet
26
1 26
Pallets per container
12
28
Pieces per container
I 312
728
Specifications are subject to change without further notification
[e] ENPHASE MICRO - INVERTER
The Enphase Energy Micro - Inverter System improves energy harvest,
increases reliability, and dramatically simplifies design, installation and
management of solar power systems. The Enphase System includes the
micro - inverter, the Envoy Communications Gateway, and the web -based
Enlighten monitoring and analysis website.
- Maximum energy production
PRODUCTIVE - Resilient to dust, debris and shading
- Performance monitoring per module
- MTBF of 331 years W
R E L I A B L E - System availability greater than 99.8% z
- No single point of system failure z
- Quick & simple design, installation and management
SMART - 24/7 monitoring and analysis
SA®
C US
MARTIN / MARTIN
CONSULTING ENGINEERS
Title 1./(Lv
Subject P110C I PV By E ll Sheet of i
Date °� —�� '.W i t Job no. ) - / 6 / ! 1
P = a-to J pl�2
rm ftr
a- P
c C- 6L -C 477
N E T t;('L(FT
SE(2 vrcc
L c - z)
6' �4 irk 1 %o." �,
c2 F Nf
-�. -0 1
MIfo/yC1 -T r/vv
LVL- _
�'�� - '4 -
�8 - 4 /t ' 5J8 r�
�,✓' = w c C,„ C
( =1 -U
c -- 0. �
t,J = C a � B��� s /8� r b�( 1� 10x �/rc,eF+�- k�T DL+ /N6 4 s r of ^-I
o k w r ,)i T-t (a1 f V C"vf .N tt< . ,6
1 ( ) f (REwr r ti fir- " �'/-/ c 4 D4 w C
r2 ECA- Lc vcA P FP2 Pl t
- c -o,vf6 Vt
FACTW OF II Poi e� Yavt
Cox t, ►�� � 1.15
19531 To
C,=
-o • :
°
09.26.2011f
' ,
r
Revision Submittals:
1. "Field Set" of approved plans MUST accompany revisions.
2. No further inspections will be performed until the revisions are approved & the permit is re- issued.
3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance.
Permit #(s) information applies to:
51O- Otl0'7
Project Street Address:
Attention: () Revisions
m () Response to Correction Letter
!! LA (ZT>I N _attached copy of correction letter
(t�;6eferred Submittal
( ) Other
(Number) (Street) (Suite #)
Building /Complex Name:
Contact Information:
Company: T - IXA) 1 ) 9: HAIL C TOM ASSM62)
Company Address:
City: State: Zip:
Contact Name:
Contact Phone:
k E -Mail
Description / List of Changes:
f5011.6R ASTALLArioni lw:memanphi
ki was ",40 ILU5Ir eiCAIMA
Revised ADDITIONAL Valuations (Labor & Materials)
(DO NOT include original valuation)
Building:
Plumbing:
Electrical:
Mechanical:
Total:
(use additional sheet if necessary)
Date Received: V [ n W f E C1 1 0
WN OF VAIL
I !J
or,
� R p YrtL
01 -Jan-10
TRANSMITTAL FORM
Power Rail"' Extrusions
Power Rail is an engineered profile extrusion made from Series 6000
structural aluminum. Standard finish is mill- finish aluminum.
P6 Standard Lengths
Power Rail P6- Extrusion
P8 Standard Lengths
Power Rail P8- Extrusion
Part #
P6 -84
P6 -126
P6 -162
P6 -204
P6 -240
P6 -282
P6 -324
E Part
84"
126"
162'
204"
240"
282"
324"
Weight
Unit (Ib
Pricing per Quantities
1 -19
5
(Higher
44.00
7.5
Volume Discount
65.00
9.5
Available)
83.00
12
103.00
14
120.00
16.5
139.00
19
158.00
20 -39
42.00
63.00
80.00
99.00
116.00
134.00
152.00
40 -59
41.00
60.00
7700
96.00
111.00
129.00
146.00
60 -79
40.00
59.00
74.00
92.00
10700
124.00
140.00
80 -99
38.00
56.00
72.00
88.00
103.00
119.00
135.00
100-
36.00
1 54.00
1 68.00
1 85.00
1 98.00
114.00
129.00
P8 Standard Lengths
Power Rail P8- Extrusion
Part #
PS -84
P8 -126
P8 -162
P8 -204
P8 -240
P8 -282
PS -324
Length
84"
126"
162"
204"
240"
282"
324"
Weight Per
Unit (Ibs.)
Pricing per Quantities
1 -19
7
(Higher
68.00
10.5
Volume Discount
?00.00
13.5
Available)
128.00
17
159.00
20
184.00
23.5
214.00
27
243.00
20 -39
65.00
97.00
123.00
153.00
178.00
206.00
234.00
40 -59
63.00
93.00
119.00
14700
171.00
198.00
225.00
60 -79
61.00
90.00
114.00
142.00
164.00
191.00
216.00
80 -99
58.00
86.00
110.00
136.00
158.00
183.00
20700
100-
56.00
83.00
105.00
130.00
151.00
175.00
198.00
(800) 260.3792
��OWER -FAB°
www.DPWSolar.com
101
POWER FAB
PRODUCT SELECTION & SPECIFICATION
Table 5-2: Wind Speed & Snow Load Application Table for Power Rail P8
W
1:1)
r�.
�s
L
POWER RAIL DESIGN GUIDELINES
SNOW LOAD (PSF)
SPAN
0
10
20
30
40
50
60
70
80
90
100
C'VER
72
60
54
48
43
40
36
33
31
29
28
90C
36
32
26
24
21
20
18
16
15
14
14
=
a.
60
58
48
46
42
38
36
33
31
29
28
�
100C
32
28
24
23
21
19
18
16
15
14
14
58/
48
44
40
37
35
33
31
29
28
w
CL
110C
28
26
24
22
20
18
17
16
15
14
14
54 /54/46
42
39
36
34
32
31
29
28
Z
120C
26
26
23
21
19
18
17
16
15
14
14
48
48
44
40
37
35
33
32
30
29
28
130C
24
24
22
20
18
17
16
Z1 6
15
V1 4
Z1 4
Table 5-2: Wind Speed & Snow Load Application Table for Power Rail P8
W
1:1)
r�.
�s
L
POWER RAIL DESIGN GUIDELINES
-1-
12- U1 -2U11 Inspection Request Reporting Page 5
4:19 pm Va�1 _ O -_City of
Requested Inspect Date: Friday, December 02, 2011
Site Address: 390 S FRONTAGE RD W VAIL
390 S FRONTAGE RD W- TRANSIT CENTER
A/P /D Information
Activity: B11 -0389 Type: COMBO
Const Type: Occupancy:
Sub Type: ACOM
Use: A -3
Status: ISSUED
Insp Area:
Owner: TOWN OF VAIL
Contractor: ACTIVE ENERGIES SOLAR, LLC
Phone: 970 - 306 -4233
Description: FLUSH MOUNTED PV SYSTEM
FOR TRANSIT CENTER
Requested Inspection
ItemLAN -FINAL
Requesto
equested Time:
Phone:
08:00 AM
Assigned To ON
Action
Time Exp:
Entered By:
MHAEBERLE K
, 3.
I I
Item: 90 BLDG-Final
Requestor:
Requested Time: me:
08:00 AM
Assigned To: JMONDRAGON
Action:
Phone:
Entered By:
MHAEBERLE K
Time Exp:
Inspection Histo
Item: 120 ELEC -Rough ** Approved **
11/21/11 Inspector: sgremmer
Comment:
Item: 130 ELEC- Conduit ** Approved **
11/21/11 Inspector: sgremmer
Comment:
Item: 190 ELEC -Final ** Approved **
11/21/11 Inspector: sgremmer
Comment:
Item: 542 PLAN -FINAL
Item: 90 BLDG -Final
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
REPT131
Run 2d: 13810
12 -01 -2011 Inspection Request Re orting Page 5
_4:19 pm Vaii. CO - City Of
Requested Inspect Date: Friday, December 02 2011
Site Address: 390 S FRONTAGE R6 W VAIL
390 S FRONTAGE RD W- TRANSIT CENTER
A/P /D Information
Activity: B11 -0389 Type: COMBO Sub Type: ACOM Status: ISSUED
Const Type: Occupancy: Use: A -3 Insp Area:
Owner: TOWN OF VAIL
Contractor: ACTIVE ENERGIES SOLAR, LLC Phone: 970 - 306 -4233
Description: FLUSH MOUNTED PV SYSTEM FOR TRANSIT CENTER
Requested Inspection(s)
Item: 542 PLAN -FINAL
Requestor:
f�ssigned To: BGIBSON
'✓ Action: Time Exp:
Requested Time: 08:00 AM
Phone:
Entered By: MHAEBERLE K
Item: 90 BLDG -Final
Requestor:
Assigned To: JMONDRAGON
Action: Time Exp:
A R::?eo ( f Ij
Inspection Histo
Requested Time: 08:00 AM
Phone:
Entered By: MHAEBERLE K
Item:
120 ELEC -Rough
** Approved **
11/21/11 Inspector:
sgremmer Action: AP APPROVED
Comment:
Item:
130 ELEC- Conduit
** Approved **
11/21/11 Inspector:
sgremmer Action: AP APPROVED
Comment:
Item:
190 ELEC -Final
** Approved **
11/21/11 Inspector:
sgremmer Action: AP APPROVED
Comment:
Item:
542 PLAN -FINAL
Item:
90 BLDG -Final
REPT131 Run Id: 13810