Loading...
HomeMy WebLinkAboutB11-0389NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MIA OF Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0389 Project #: Job Address: 390 S FRONTAGE RD W VAIL Location......: 390 S FRONTAGE RD W- TRANSIT CENTER Parcel No....: 210106407012 OWNER TOWN OF VAIL 10/03/201' C/O FINANCE DEPT 75 S FRONTAGE RD VAIL CO 81657 APPLICANT ACTIVE ENERGIES SOLAR, LLC PO BOX 7627 AVON CO 81620 License: C000003295 CONTRACTOR ACTIVE ENERGIES SOLAR, LL( PO BOX 7627 AVON CO 81620 License: C000003295 10/03/2011 Phone: 970-306-4233 10/03/2011 Phone: 970-306-4233 Description: FLUSH MOUNTED PV SYSTEM FOR TRANSIT CENTER Occupancy: A -3 Type Construction: VB Applied.....: Issued... PRJ 10 -0346 10/03/2011 10/28/2011 Valuation: $29,123.00 .. ............................... ................ ............................... FEE SUMMARY ...... .......�,...................... <.... ...........�......,........,... Building Permit ------ - - - - -> $441.75 Bldg Plan Check ----- - - - - -> $287.14 Use Tax Fee------------------ - - - - -> $382.46 Electrical Permit ---- - - - - -> $0.00 Elec Plan Check ------ - - - - -> $0.00 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees--------------- - - - - -> ($116.35) Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $5.00 TOTAL PERMIT FEES -- ----------- > $1,000.00 Payments -- ---------------------------- > $1,000.00 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. 8:00 AM - 4 FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM Signature of '-b' ontractor Print Name Date combination permit_012811 MwNoFV� CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0389 Owner: TOWN OF VAIL FRONTAGE RD W- TRANSIT CENTER Address: 390 S FRONTAGE RD W VAIL Location: 390 S combination permit_012811 O V�AIL iu ,rw *r ** • trw*** r t*, t r*****r* t+ x**, r*, r****, r****+ r, r**, r, r*, r, rw*** tr*, r***, r*, r * *,r *rr * * * * *r *,r * *,r,r,r * * * * * ** r*** trr* rtrrr*, r* arxr, r*, r, r, rw*** r, r, rr, r, rrr, t* *,r * *t+r * *,r,r,r *,r *,r,r,r * * * ** REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0389 Owner: TOWN OF VAIL FRONTAGE RD W- TRANSIT CENTER Address: 390 S FRONTAGE RD W VAIL Location: 390 S Item: 00120 ELEC -Rough Item: 00130 ELEC- Conduit Item: 00190 ELEC -Final Item: 00542 PLAN -FINAL Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110001572 Amount: $1,000.00 10/28/201108:55 AM Payment Method: Check Init: SAB Notation: 1572 - ACTIVE ENERGIES ----------------------------------------------------------------------------- Permit No: Bll -0389 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 064 - 0701 -2 Site Address: 390 S FRONTAGE RD W VAIL Location: 390 S FRONTAGE RD W- TRANSIT CENTER Total Fees: $1,000.00 This Payment: $1,000.00 Total ALL Pmts: $1,000.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- 00100003111100, GFPO ELEC PERMIT FEES- GFP012 1,000.00 TOWN OF VAN.' Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 -479 -2128 www.vailgov.com Development Review Coordinator SOLAR THERMAL /PHOTOVOLTAIC PERMIT APPLICATION (Separate applications are required for a new electrical panel or any roof alteration) Project Street Address: 395 East Lionshead Circle (Number) (Street) (Suite #) Building /Complex Name: ToV Lionshead Transit• Contractor Information Active Energies Solar LLC Project #: -ek 11 I — 1�3y DRB #: U6 jlJ�lp3 Permit #: Lot #: Block # Subdivision: Business Name. PO Box 7627 Work Class: New ( ✓) Addition ( ) Alteration ( ) Business Address: City Avon CO 81620 Zip: p: Type of Building: Single- Family ( ) Duplex( ) Multi- Family ( ) Jason Wein ast Contact Name: g Commercial ( ✓) Other ( ) Contact Phone: 970 - 306 -4233 Contact E -Mail: j ason@activeenerg ies.com 9 Work Type: Interior ( ) Exterior ( ) Both ( ✓ ) - _... -__ .. X Solar Type:. Owner /Owner's Representative Signature (Required) Photovoltaic ( ✓) Solar Thermal ( ) Applicant Information - -- - flk_C4 -6y- � L AZ S Applicant Name: Jason Weingast n Applicant Phone: 970- 306 -4233 Applicant E -Mail: Jason @activeenergies.com Project Information Town of Vail Owner Name: Parcel #: Value of all work being performed: $ 29. (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit —.eaglecounty.us/patte) (value based on IBC Section 109.3 8 IRC Section 108.3) Detailed Scope and Location of Work: DC side of 5.55kW flush mounted PV system (use additional sheet if necessary) For Office Use Only: Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Date D SEP 3 0 2011 TOWN OF VAIL IS -Jul -11 I O K J N J a C O O n 00 T N O b O N N J 0 N J N O w O 0 o ON W% IN 0 R D .A L e u � m - 6 r� J a � 0 n (n I d Z n � Q w v - a m ............... ..a vw OFFICE . COPY d m n� � m m a D 3 c n 0 0 --i w D < < M d N (n rm 00 n w s + � d � 4 n C7 () N (D 9 1 m K cn d C71 N < c C71 ID N 7� o m m v -° °� m w C p_ D x x (p m= :. o c. O d d wo u) '� C N 3 7 0 'T, N < C o D $ m (o (o a (� o � -��' (o � (7 < vt v i i oo CCD o V C C C C . y A II n N p N o m w (.Ail --I (n N CD n 3 m o D< v < 0o rn .. `° `r m 3 W N ( A (D O D< D< y o p m n Q n K a � m n m 0 Z - g F m d < x rn 9: m m j��L o� o m • ,ak i'l w r c /W► kwo i OJ N O _ O • -9 U ' o ' - ' O ' D O O N N ' A(Dy S N O G< 7 N7 ( S <O m ON E' (D c [n D w w o m nv c n �o < +m m m m u� oo m° o' , m Na 0 (D (D Z7 O �' O. N m O / D� cn m o m o o Z C cnmm �' m C7 m rn r m �. rn a o n N N- a O d N n (O -1 O (D O (p ,C.. v °mw> W CD m c m o D oC P n M o c o u O n> > m ..a vw OFFICE . COPY d m n� � m m a D 3 c n 0 0 --i w D < < M d N (n rm 00 n w s + � d � 4 n C7 () N (D 9 1 m K cn d C71 N < c C71 ID N 7� o m m v -° °� m w C p_ D x x (p m= :. o c. O d d wo u) '� C N 3 7 0 'T, N < C o D $ m (o (o a (� o � -��' (o � (7 < vt v i i oo CCD o V C C C C . y A II n N p N o m w (.Ail --I (n N CD n 3 m o D< v < 0o rn .. `° `r m 3 W N ( A (D O D< D< y o p m n Q n K a � m n m 0 Z - g F m d < x rn 9: m m j��L o� o m • ,ak i'l w r c /W► kwo i A - rivi.. ENF,I?( #IH 5.55kW System Size (STC) CALCULATIONS 30 Suntech STP 1855- 24 /Adb+ black solar panels @ 185watts 30 Enphase M -190 micro - inverters 208v — 2 branches of 15/15 units Fixed array tilt angle: 22.6° Array azimuth: 180° (where 180° is south) Estimated annual power production: 7,975kWh Mounting Feet: DPW Easy Power Posts Mounting Rail: Direct Power and Water's Power Rail P8 - Extrusion Maximum PV System Voltage: 690.7 Voc = 45V /module 45V x 1 module = 45V Temperature correction factor 690.7(A) STC = 25 °C, Temperature Coefficient (Voc) _ - 0.34 % / °C (25 °C - -40 °C) _ -65 °C 45V x ( -65 °C x (- .34 % / °C) x 1 module) + 45V = 55V Temperature correction factor Table 690.7 For -40 °F use 1.25 45V x 1.25 = 56.3V Maximum PV Source Circuit (String) Current: I = 5.43A 5.43A x 1.25 = 6.8A Maximum PV Output Circuit (Array) Current: Qj 1 strings = 6.8A Invertei u Cirt Ctirrent: ZQ�A- a 208V John Wiles, " ot oAZc Power Systems and the National Electrical Code: Suggested Practices ", 20 El 690.8 (A)(1) 690.8 (A)(2) 690.8 (A)(3) pdf version -,&li e atp http:/ /Nvww nmsu.edu/%7Etdi/Photovoltaics/Codes- Stds /PVnecSuQPract.html P age 2 of 4 9/26/2011 P,0, Box 1627, Avm 00 216201 P. 970.227.0272 i "G3.330.=0 ( F. 26640334-5 `! C x;-arw.wt veeurrg es.cazn C K Z Acvivi E.N .12t =IFs SOT .1lt sX- CONDUCTOR SIZING Pass Thru Box to AC Disconnect /Panel (for a 15 panel circuit): Nameplate maximum continuous output current: .92A Maximum Output Power 190 Watts AC 190 W _ 208 V =.92A .92A x 5 inverters per phase = 4.6A per phase per branch 4.6A x 1.73 = 8A per leg 8A x 125% = 10A #10 THWN -2 Table 310.16 30A (90 °C column, see note 240.4(D)) Conduit fill adjustment No Conduit Fill Adjustment Temperature correction factor No Temperature Correction Overcurrent Protection Device per circuit 2 - 15A three pole breakers -°t O W C) 0 6 M Table 310.15 (13)(2)(a) Table 310.16 Per Manufacturer Specification Alk / ! / ! e L z ( P age 3 of 4 9/26/2011 P.0, Boz "%27, Avmi fC0.8I62a I P: 97,0 - 7 M72 t 303.330.Sd0 J F: 266.4033425 1 wwwrsLwener ies com ArOWER -FAB Peel off protective Paper Easy Post (bottom of base) Butyl Mastic Figure 1: Removing Protective Paper �1/4x1'/z" RSS PHEinox Screw (6 places) � Neoprene Bonded Washer (rubber side down) 4 "_ 15/16" 4" Easy Post 1 /s "� (press firmly onto Roof � �f-- 4 " —+1 --f Substrate) CD CAD, ,. Fi_qure 2: Securing Easy Post Installation Guidelines Post to Roof Field locate center holes directly over LVL below. Version 1, RevA PCN 072210 -1 / , * Other heights available 3�1 -o3�s F,I:t;II. :S SMIAR SOLAR INSTALLATION INFORMATION Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970- 306 -423 3 /info @activeenergies. com) Site: ToV Lionshead Transit Center 395 East Lionshead Circle Vail, CO 81657 MARTIN/MARTIN, INC. REVIEWED FOR GENERAL ARRANGEMENT. REVIEW SUBJECT TO COMPLIANCE WITH ALL CONTRACT REQUIREMENTS. DETAILED DIMENSIONS AND QUANTITIES NOT CHECKED. EXCEPTIONS AS NOTED Date Received 09/26/2011 Reviewer: ERS Date Returned: 0926/2011 All AC wiring to be completed by a Colorado licensed master electrician—. _ All DC wiring to be overseen by NABCEP certified installer T- Photovoltaic AC Disconnects located adjacent to the main service panel and meter. Minimum Designed Temperature: -40QF Maximum Ambient Design Temperature: 140QF Panel Arrangement: O CD � C r GQ rn m ,n X 0 Not to scale P age 1 of 4 ' 1 a 9/26/2011 P.O Rcs "x627, Avaa; 00 21620 1 P; 470.22 ?.0272 1303.330.4 0 1 F 266.4033425 1 www,ec6veanergieszom l MICRO - INVERTER TECHNICAL DATA Input Data (DQ M190 -72- 208 -511/2 M190 -72- 240 -511/2 Recommended input power (STC) 230W 230W Maximum input DC voltage 54V 54V Peak power tracking voltage 22V — 40V 22V — 40V Max. DC short circuit current 12A 12A Max. input current 10A 10A Output Data (AQ Maximum output power 190W 190W Nominal output current 920mA 800mA Nominal voltage /range 208W1 83V-229V 240V/211V -264V Extended voltage /range 208V/179V -232V 240W206V -269V Nominal frequency /range 60.0/59.3 -60.5 60.0/59.3 -60.5 Extended frequency /range 60.0/59.2 -60.6 60.0/59.2 -60.6 Power factor >0.95 >0.95 Maximum units per branch 21 15 Efficiency Peak inverter efficiency 95.5% 95.5% CEC weighted efficiency 95.0% 95.0% Nominal MPP tracking 99.6% 99.6% Mechanical Data Operating temperature range -40 °C to +65 °C -40 °C to +65 °C Night time power consumption 30mW 30mW Dimensions (WxHxD) 8" x 5.25" x 1.25" Weight 4.4 Ibs Cooling Natural Convection — No Fans Enclosure environmental rating Outdoor— NEMA 6 Features Communication Powerline 13 Warranty 15 Years ' { i Compliance UL1741 /IEEE1547 � FCC Part 15 Class B AM Enphase Energy Inc. 142 -00005 REV 02 u 201 1st Street, Suite 300, Petaluma, CA 94952 9 ph 877 797 4743 enphaseenergy.com ® Printed on 100 percent recycled paper. vi N4 M OdHI NI =1-40 WHaL IHOHS 4 ";;p 5 - SIN3K3A021dWINOLL03Sd31N1)3j51E)dHI82Li51013 - WS NO ONIGIM on oNv skve sna oo3 - �131N30 iISN�Ji OV3HSN0I M11- wl- um III I I I ICI MIM 0 IL O X HUI co CD I II x UJ 0 CL CD Lo (D > as CD rq A cz c0 a) CL (D co (D LQ LL 0 CD cz M11- wl- um III I I ICI um J SUN TECH Solar powering a green future" 185 Watt MONOCRYSTALLINE SOLAR MODULE Suntech Black LabelTM modules are exclusively designed and engineered for homeowners who seek a rooftop solar solution that combines visual aesthetics with excellent efficiency. Features High module conversion efficiency (up to 14.5 %), through superior manufacturing technology Guaranteed 0 -5W positive power output tolerance ensures high reliability Proprietary Gallium -F22 doping process dramatically reduces initial light- induced degradation to <1 %, thus delivering better power and performance over time Entire module certified to withstand high wind ,,. loads (2400 Pascal) and snow loads (5400 Pascal) Trust Suntech to Deliver Reliable Performance Over Time • World's leading manufacturer of crystalline silicon photovoltaic modules • Unrivaled manufacturing capacity and world -class technology • Rigorous quality control meeting the highest international standards: ISO 9001: 2008 and 150 14001: 2004 • Certification and standards: IEC 61215, IEC 61730, conformity to CE Industry - leading warranty SUNTECH g n 25 year transferrable power output warranty: 5 year /95 %, 12 year /90%, 18 year /85 %, 25 year /80% ** Based on nominal power Warrants 6.7% more power than the market standard over 25 years 5 year material and workmanship warranty * Please refer to Suntech Standard Module Installation Manual for details. **Please refer to Suntech Product Warranty for details. Patented surface pyramids enhance sunlight absorption by redirecting reflected light to other areas on the cell t surface to be reabsorbed z 7. Suntech cells feature a breakthrough process that ee replaces traditional boron doping with gallium doping. The effect of initial light - induced , degradation is dramatically reduced, leading to greater power output over the entire module lifetime. Graph is for illustration only and does not imply any guarantee of module performance. Please check warranty for details. @Copyright 2010 Suntech Power ®TCEc°.uS DrW-, halny ""Il e pYaE AL 2 pl 100 2�✓ ' z G pacas Section A -A I Note: mm (inch) Current - Voltage & Power - Voltage Curve (1855 -24) u' voltage M = I- = --I- cao- _ Sao- = mo- Temperature Characteristics zoo lao 1� Iw _ Izo 3 IN 3 eo u m Nominal Operating Cell Temperature (NOCT) 4512 °C Temperature Coefficient of Pmax -0.48 %/°C Temperature Coefficient of Voc (Back View) Temperature Coefficient of Isc 0.037 %/°C _i_ = e3�eeee e_e_ ==ee Maximum Power at STC (Pmax) 185 W 180 W Module Efficiency 14.5 % 14.1% Current - Voltage & Power - Voltage Curve (1855 -24) u' voltage M = I- = --I- cao- _ Sao- = mo- Temperature Characteristics zoo lao 1� Iw _ Izo 3 IN 3 eo u m Nominal Operating Cell Temperature (NOCT) 4512 °C Temperature Coefficient of Pmax -0.48 %/°C Temperature Coefficient of Voc -0.34 %/°C Temperature Coefficient of Isc 0.037 %/°C Dealer information box Electrical Characteristics Optimum Operating Voltage (Vmp) 36.4 V 36.0 V Optimum Operating Current (Imp) 5.09 A 5.00 A Open - Circuit Voltage (Voc) 45.0 V 44.8 V Short - Circuit Current (Isc) 5.43 A 5.29 A Maximum Power at STC (Pmax) 185 W 180 W Module Efficiency 14.5 % 14.1% Operating Temperature -40 °C to +85 °C -40 ° C to +85 ° C Maximum System Voltage 600 V DC 600 V DC Maximum Series Fuse Rating 15A 15A Power Tolerance 045 W 0/ +5 W STC: Irradiance 1000 W /mz, module temperature 25 °C, AM =1 S unrr crosoee �nrna� cro�one_�n iad� Maximum Power (W) 137W 133 W Maximum Power Voltage (V) 33.2 V 32.9 V Maximum Power Current (A) 4.11 A 4.05 A Open Circuit Voltage (Voc) 41.3 V 40.9 V Short Circuit Current (Isc) 4.39 A 4.30 A Efficiency Reduction (from 1000 W /m' to 200 W /m') <4.5% <4.5% NOCT: Irradiance 800 W /m', ambient temperature 20 °C, wind speed 1 m/s Mechanical Characteristics Solar Cell Monocrystalline 125 x 125 mm (5 inches) No. of Cells ......... ... ............................... 72 (6 x 12) .. .. Dimensions 1 26 1580 x 808 x 35mm (62.2 x 31.8 x 1.4 Inches) Weight 12 15.5 kgs (34.1 lbs.) Front Glass I 312 3.2 mm (0.13 inches) tempered glass Frame .......... .. . Anodized aluminium alloy Junction Box IP67 rated H +S RADOX" SMART cable 4.0 mm' (0.006 Inches'), Output Cables symmetrical lengths ( -) 1000 mm (39.4 inches) and ( +) 1000 mm (39.4 inches), H4 connectors (MC4 compatible) Packing Configuration Container 20' GP 40' GP Pieces per pallet 26 1 26 Pallets per container 12 28 Pieces per container I 312 728 Specifications are subject to change without further notification [e] ENPHASE MICRO - INVERTER The Enphase Energy Micro - Inverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the micro - inverter, the Envoy Communications Gateway, and the web -based Enlighten monitoring and analysis website. - Maximum energy production PRODUCTIVE - Resilient to dust, debris and shading - Performance monitoring per module - MTBF of 331 years W R E L I A B L E - System availability greater than 99.8% z - No single point of system failure z - Quick & simple design, installation and management SMART - 24/7 monitoring and analysis SA® C US MARTIN / MARTIN CONSULTING ENGINEERS Title 1./(Lv Subject P110C I PV By E ll Sheet of i Date °� —�� '.W i t Job no. ) - / 6 / ! 1 P = a-to J pl�2 rm ftr a- P c C- 6L -C 477 N E T t;('L(FT SE(2 vrcc L c - z) 6' �4 irk 1 %o." �, c2 F Nf -�. -0 1 MIfo/yC1 -T r/vv LVL- _ �'�� - '4 - �8 - 4 /t ' 5J8 r� �,✓' = w c C,„ C ( =1 -U c -- 0. � t,J = C a � B��� s /8� r b�( 1� 10x �/rc,eF+�- k�T DL+ /N6 4 s r of ^-I o k w r ,)i T-t (a1 f V C"vf .N tt< . ,6 1 ( ) f (REwr r ti fir- " �'/-/ c 4 D4 w C r2 ECA- Lc vcA P FP2 Pl t - c -o,vf6 Vt FACTW OF II Poi e� Yavt Cox t, ►�� � 1.15 19531 To C,= -o • : ° 09.26.2011f ' , r Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: 51O- Otl0'7 Project Street Address: Attention: () Revisions m () Response to Correction Letter !! LA (ZT>I N _attached copy of correction letter (t�;6eferred Submittal ( ) Other (Number) (Street) (Suite #) Building /Complex Name: Contact Information: Company: T - IXA) 1 ) 9: HAIL C TOM ASSM62) Company Address: City: State: Zip: Contact Name: Contact Phone: k E -Mail Description / List of Changes: f5011.6R ASTALLArioni lw:memanphi ki was ",40 ILU5Ir eiCAIMA Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: Plumbing: Electrical: Mechanical: Total: (use additional sheet if necessary) Date Received: V [ n W f E C1 1 0 WN OF VAIL I !J or, � R p YrtL 01 -Jan-10 TRANSMITTAL FORM Power Rail"' Extrusions Power Rail is an engineered profile extrusion made from Series 6000 structural aluminum. Standard finish is mill- finish aluminum. P6 Standard Lengths Power Rail P6- Extrusion P8 Standard Lengths Power Rail P8- Extrusion Part # P6 -84 P6 -126 P6 -162 P6 -204 P6 -240 P6 -282 P6 -324 E Part 84" 126" 162' 204" 240" 282" 324" Weight Unit (Ib Pricing per Quantities 1 -19 5 (Higher 44.00 7.5 Volume Discount 65.00 9.5 Available) 83.00 12 103.00 14 120.00 16.5 139.00 19 158.00 20 -39 42.00 63.00 80.00 99.00 116.00 134.00 152.00 40 -59 41.00 60.00 7700 96.00 111.00 129.00 146.00 60 -79 40.00 59.00 74.00 92.00 10700 124.00 140.00 80 -99 38.00 56.00 72.00 88.00 103.00 119.00 135.00 100- 36.00 1 54.00 1 68.00 1 85.00 1 98.00 114.00 129.00 P8 Standard Lengths Power Rail P8- Extrusion Part # PS -84 P8 -126 P8 -162 P8 -204 P8 -240 P8 -282 PS -324 Length 84" 126" 162" 204" 240" 282" 324" Weight Per Unit (Ibs.) Pricing per Quantities 1 -19 7 (Higher 68.00 10.5 Volume Discount ?00.00 13.5 Available) 128.00 17 159.00 20 184.00 23.5 214.00 27 243.00 20 -39 65.00 97.00 123.00 153.00 178.00 206.00 234.00 40 -59 63.00 93.00 119.00 14700 171.00 198.00 225.00 60 -79 61.00 90.00 114.00 142.00 164.00 191.00 216.00 80 -99 58.00 86.00 110.00 136.00 158.00 183.00 20700 100- 56.00 83.00 105.00 130.00 151.00 175.00 198.00 (800) 260.3792 ��OWER -FAB° www.DPWSolar.com 101 POWER FAB PRODUCT SELECTION & SPECIFICATION Table 5-2: Wind Speed & Snow Load Application Table for Power Rail P8 W 1:1) r�. �s L POWER RAIL DESIGN GUIDELINES SNOW LOAD (PSF) SPAN 0 10 20 30 40 50 60 70 80 90 100 C'VER 72 60 54 48 43 40 36 33 31 29 28 90C 36 32 26 24 21 20 18 16 15 14 14 = a. 60 58 48 46 42 38 36 33 31 29 28 � 100C 32 28 24 23 21 19 18 16 15 14 14 58/ 48 44 40 37 35 33 31 29 28 w CL 110C 28 26 24 22 20 18 17 16 15 14 14 54 /54/46 42 39 36 34 32 31 29 28 Z 120C 26 26 23 21 19 18 17 16 15 14 14 48 48 44 40 37 35 33 32 30 29 28 130C 24 24 22 20 18 17 16 Z1 6 15 V1 4 Z1 4 Table 5-2: Wind Speed & Snow Load Application Table for Power Rail P8 W 1:1) r�. �s L POWER RAIL DESIGN GUIDELINES -1- 12- U1 -2U11 Inspection Request Reporting Page 5 4:19 pm Va�1 _ O -_City of Requested Inspect Date: Friday, December 02, 2011 Site Address: 390 S FRONTAGE RD W VAIL 390 S FRONTAGE RD W- TRANSIT CENTER A/P /D Information Activity: B11 -0389 Type: COMBO Const Type: Occupancy: Sub Type: ACOM Use: A -3 Status: ISSUED Insp Area: Owner: TOWN OF VAIL Contractor: ACTIVE ENERGIES SOLAR, LLC Phone: 970 - 306 -4233 Description: FLUSH MOUNTED PV SYSTEM FOR TRANSIT CENTER Requested Inspection ItemLAN -FINAL Requesto equested Time: Phone: 08:00 AM Assigned To ON Action Time Exp: Entered By: MHAEBERLE K , 3. I I Item: 90 BLDG-Final Requestor: Requested Time: me: 08:00 AM Assigned To: JMONDRAGON Action: Phone: Entered By: MHAEBERLE K Time Exp: Inspection Histo Item: 120 ELEC -Rough ** Approved ** 11/21/11 Inspector: sgremmer Comment: Item: 130 ELEC- Conduit ** Approved ** 11/21/11 Inspector: sgremmer Comment: Item: 190 ELEC -Final ** Approved ** 11/21/11 Inspector: sgremmer Comment: Item: 542 PLAN -FINAL Item: 90 BLDG -Final Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED REPT131 Run 2d: 13810 12 -01 -2011 Inspection Request Re orting Page 5 _4:19 pm Vaii. CO - City Of Requested Inspect Date: Friday, December 02 2011 Site Address: 390 S FRONTAGE R6 W VAIL 390 S FRONTAGE RD W- TRANSIT CENTER A/P /D Information Activity: B11 -0389 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: A -3 Insp Area: Owner: TOWN OF VAIL Contractor: ACTIVE ENERGIES SOLAR, LLC Phone: 970 - 306 -4233 Description: FLUSH MOUNTED PV SYSTEM FOR TRANSIT CENTER Requested Inspection(s) Item: 542 PLAN -FINAL Requestor: f�ssigned To: BGIBSON '✓ Action: Time Exp: Requested Time: 08:00 AM Phone: Entered By: MHAEBERLE K Item: 90 BLDG -Final Requestor: Assigned To: JMONDRAGON Action: Time Exp: A R::?eo ( f Ij Inspection Histo Requested Time: 08:00 AM Phone: Entered By: MHAEBERLE K Item: 120 ELEC -Rough ** Approved ** 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 130 ELEC- Conduit ** Approved ** 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC -Final ** Approved ** 11/21/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 542 PLAN -FINAL Item: 90 BLDG -Final REPT131 Run Id: 13810