HomeMy WebLinkAboutB11-0404NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
_ ,.
�u� o� �� �
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B11-0404
Job Address: 186 GORE CREEK DR VAIL
Location......: LODGE AT VAIL - UNIT 154
Parcel No....: 210108221015
OWNER TOCHTER LLC 10/04/2011
PO BOX 2736
EDWARDS
CO 81632
CONTRACTOR EVANS CHAFFEE CONSTRUCTION G 10/24/2011
MICHELLE EVANS
PO BOX 8266
AVON
CO 81620
License: C000003077
Phone: 970-845-0466
APPLICANT LKSM DESIGN 10/04/2011 Phone: 970-376-6623
LEAH MAYER
PO BOX 9195
AVON
CO 81620
Description:
INTERIOR RENOVATIONS INCLUDING REMOVING AND REPLACING
INTERIOR FINISHES, CONSTRUCTING A SMALL OFFICE AND STORAGE
AREA IN THE BACK OF THESPACE. INSTALL NEW STOREFRONT GLASS
SYSTEM.
Occupancy: M Type Construction: IIIB
Project #:
Applied.....:
Issued. . . ;
P RJ 11-0415
10/04/2011
10/28/2011
Valuation; $100,000.00
............>..x......,,.,,,>,.,.......,, .............x..,.,,,....................... FEE SUMMARY ...,........,�........,.,..�..,...........,..,,...._......_..................�..,.
Building Permit -----------> $993.75 Bldg Plan Check ----------> $645.94 Use Tax Fee-----------------------> $1,800.00
Electrical Permit ---------> $345.00 Elec Plan Check -----------> $224.25 Restuarant Plan Review--------> $0.00
Mechanical Permit ------> $60.00 Mech Plan Check ---------> $15.00 Additional Fees--------------------> $0.00
Plumbing Permit --------> $0.00 Pimb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $15.00
TOTAL PERMIT FEES-------------> $4,098.94
Payments------------------------------> $4,098.94
BALANCE DUE-----------------------> $0.00
.....................,..... «..................... «............,.,..............,,....+..>... x.... <..........,.................,,.......................... �. �.................+..,.,.,...
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM -.: 0-PM� J�2 '� � t l
� ,
Signature of Owner or Contractor Date
�,.ul.� (, 'J �J C'l/LC- 'S
Print Name
combination permit_012811
t
�
��� �� �� a
x'k+kwww+ewwFitftr+hY�Yr+#':Y#YrYr4i1'i1'#rtrt#Yeflrtrt�*rt*4fff`AliFf w+hqwYertfwfiw/Y'YrhYeil'hrtrtrtwYeYrY'Y'Y(#'iFhY'kwYr�,FftrhwrtiYrftril'�kw#YIYIYeYIM'i1'wk�k#�k444'k#rt#*1(1`1«fi(*#f*�F#ir*i(rt#**+d1`t(1(*RR***Rt`At`k4**t1`*1(rt+ffr�R*i(i(*rti1(1`rt4*��##4ir�*
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: 611-0404 Address: 186 GORE CREEK DR VAIL
Owner: TOCHTER LLC Location: LODGE AT
VAIL - UNIT 154
•'k'k #il'Y`f f i1'Y'Yf rt fF+t MYr>4R�ririf f trt(wfnit`t(t`w'kf Yehf iMrtithYY#iPrt%%'i1'�1'�k�k#�i(Y(Yr1(!tf(fii*** ***t`#t(f>�R*Ax*teteRXkf 4�RX*Y'Yee*lRYrrtxrtY�Y'�kYtYeYeM'M' M'kM'kf R**Y(**# ***ir*# ****t�4t�R1eA**RkR#*4t44**Rt�A'*/*wf+***kRYritMM#***xiFt***iR�R+
Cond: CON0012232
provide flame spread information for awning
combination permit_012811
:
.... ' �
1 V�►11 V.� i1�L ,
**„***„*.,.,**..***„***,*,*******************************.,.***********��*********************.,*******„***********.,.,*******.********�.******„****,,,,*****
Permit #: 611-0404
Owner: TOCHTER LLC
VAIL - UNIT 154
REQUIRED INSPECTIONS AND STATUSES
Address: 186 GORE CREEK DR VAIL
Location: LODGE AT
*****,�*,.*«,.************************,.*.*,,,,«**„*„******«*««*««***„******************�******************„************«„*«********««««**.*„«««********„*«
Item: 00120 ELEC-Rough
Item: 00200 MECH-Rough
Item: 00030 BLDG-Framing
Item: 00050 BLDG-Insulation
Item: 00060 BLDG-Sheetrock Nail
Item: 00190 ELEC-Final
Item: 00390 MECH-Final
Item: 00090 BLDG-Final
Item: 00542 PLAN-FINAL
combination permit_012811
****************�*****************************+**�**********************************+****�**
TOWN OF VAIL, COLORADO Statement
*******************************�***********************************************++*****++****
Statement Number: R110001575 Amount: $3,453.00 10/28/201103:13 PM
Payment Method: Check Init: SAB
Notation: 11016 - EVANS
CHAFFEE
-----------------------------------------------------------------------------
Permit No: B11-0404 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-082-2101-5
Site Address: 186 GORE CREEK DR VAIL
Location: LODGE AT VAIL - UNIT 154
Total Fees: $4,098.94
This Payment: $3,453.00 Total ALL Pmts: $4,098.94
Balance: $0.00
***************+********�******�****************************************************+*******
ACCOUNT 1TEM LIST:
Account Code
--------------------
BP 00100003111100
EP 00100003111100
MP 00100003111100
PF 00100003112300
UT 11000003106000
WC 00100003112800
Description
------------------------------
BUILDING PERMIT FEES
ELECTRICAL PERMIT FEES
MECHANICAL PERMIT FEES
PLAN CHECK FEES
USE TAX 4%
WILL CALL INSPECTION FEE
Current Pmts
993.75
345.00
60.00
239.25
1,800.00
15.00
David Rhoades
From: Tom Nern <tnern@vaildermatology.com>
Sent: Monday, October 24, 2011 221 PM
To: David Rhoades
Subject: Letter for new GC
Dear David,
Does you need a paper letter to inform you that we are switching contractors to Evans-Chaffee or well the email suffice.
Reference:
186 Gore Creek Drive, 611-0404
Skin by Vail Dermatology in The Lodge at Vail
Please be aware switching from Shaeffer Construction to Evans-Chaffee and their contact info is:
Evans-Chaffee Construction Group
Chris Evans
P.O. Box 8266
Avon, Colorado 81620
970-845-0466
970-845-0465 fax
CEvans@evanschaffee.com
Thankyou
Tom Nern
CEO
Vail Dermatology
tnern@vaildermatology.com
O 970.926.9226 x115
C 970.390.9285
TOWN D� VAIL��
Department of Community Developrnent
75 South Frontage Road
Vail, CO 81657
Tel: 970-479-2128
www.vailgov.com
Development Review Coordinaior
TRANSMITTAL FORM
Revision Submittals:
1. "Field SeY' of approved plans MUST accompany revisions.
2. No further inspections will be perFormed until the revisions are approved & the permit is re-issued.
3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance.
Permit #(s) information applies to: Attention: () Revisions
j� �1 ( LJ� ponse to Correction Letter
� ) � � — Q -1 � � _ �L�G _ _attached copy of correction letter
( ) Deferred Submittal
( ) Other
Project Street Address:
_�(� �r�6?� �'�C.�� /�2l VC.
(Number) (Street) (Suite #)
BuildinglComplex Name:
Contractor Information
Business Name: j►���'Git lJ��l VS.
Business Address:
City
Contact Name:
State: Zip:
Description / List of Changes:
f2�sPoNSE T �'�2P.�c� ��,vs
(use additional sheet if necessary)
Contact Phone: _
�I Revised ADDITIONAL Valuations (Labor 8� Materials)
Contact E-MaiL �F'�1�°L/�Q.r � I IGS�')') C�e-�1��1 •�j%1 (DO NOT include original valuation�
Owner/Owner's Representative Signature (Required)
Applicant Information
Applicant Name:
Applicant Phone:
Applicant E-Mail:
For Office Use Only:
Fee Paid:
Received From:
Cash Check # _
CC: Visa / MC Last 4 CC #
Auth #
exp. date:
Building:
Plumbing:
Electrical:
Mechanical:
Total:
Date Received:
$
$
$
$
$
p ���o��
OCT 2 1 2011
TOWN OF VAIL
o�-o�c-� i
S
D E S 1 G N
PO Box 9195 � Avon, CO � 81620
970.376-6623 d- Imayer@Iksmdesign.com
October 21, 2011
Martin A. Haeberle
Chief Building Offiaal
RE: 186 Gore Creek Drive
� _ B 11-0404 �-
Skin by Vail Dermatology
New Retail Store in The Lodge at Vail
Vail, Co
Dear Mr Haeberie;
This letter is in response to your comment letter for a permit at the above referenced space in the
lodge at Vail. Below are your comments and my responses. I am retuming this with 4 complete sets
for your re-review.
BUILDING COMMENTS
Architectural Comments:
Sheet A1.1
1. Provide proposed and existing occupancy classification and building rype per section 1072 IBC
This is noted on this sheet. This scope of work does not change the existing occupancy
classification or building type.
2. Show how compliance with section 2902, minimum plumbing fixtures is being achieved. Note:
InGude plans for travel distance location and fi�ure calculations. See sections 2902.1.1, 2902.3,
2902.3.1, and 2902.3.2 IBC. Not required if same occupancy Gassification and occupant load
The occupancy classification and load do not change in this scope of work
3. How is the exit discharge to be illuminated. Reference section 1006 IBC
Sheet A4.1 and E2 show an exterior light fixture which complies with the section 1006.
Sheet A2.1
1. Please clarify the conflict of plans showing the storage space and office space in the same area.
The area shown on the plans is intended for storage and has been revised on sheet M1.1
Sheet A3.1
1. Provide the u value of proposed glazing and doors for the storefront showing compliance with the
IECC.
Page 2
October21, 2011
A note has been added to show the maximum u value allowed per table 502.3. The proposed
storefront specified on the drawings complies with this and I have attached a cut sheet with
this letter.
Sheet A4.1
1. Details do not reflect the required weather protection per section 1405.2 IBC
A note has been added and the details revised to show that this section must be complied
with.
Structural Comments:
NA
Plumbing Comments:
See architectural comments
See comments above
Mechanical Comments:
Reviewed and accepted
Electrical Comments:
See architectural comments
See comments above
PLANNING COMMENTS
Reviewed and accepted
FIRE COMMENTS
Reviewed and accepted
PUBLIC WORKS COMMENTS
Construction staging plan required if to be in right of way
The General Contractor will not be working in the right of way during construction.
Thank you.
� �°� � �� ��
� ��,' . �',
Regards, ,�,,��,: � �4 "�±,�
i�� -�--� �
Leah KS Mayer
Cc: Chris Evans
Tom Nem
�� �� ��i. . . *�r�. �
.. t : i . .t�`3:!�
`� : �i 1 � .. �� �Y��`� �
�t
.` i
� �
,� �,
t ,,���+ a�,
__;;,
vail dermatology � skin
186 E. Gore Creek Drive
s`,,,'r-�
ProJect Name: Hooker
Fnme Set Name: Frame Set 1
Metal Group: M451T CG/SS/OG STOPS DOWN
Requlred: 1 Back Member Cdor. #17 CLEAR :
Frame Name: Frame 1
DIS: 1 Frame Type: Standard Frame Width: 144
O�C ,� Face Member Color. NULL
144 (O R) f �
�(-�-- Z4 � � Z4 � � 36 � � z4 � � 24 �
I
�
�
318
�
I� � ('C�`�0`�
Dffie: 8/15/11 8:46 AM
Panels: 5 Rows: 1
frame Height: 90
/ \V /l
"v
\/� /''
%
'p �l
A.FR)
SIZE-89518
Paye: 1 Of 1
,
Q
.���
Ss��
j� O
� . �
g��g
O
����
����
��
��o�
� u �
m q R� �
s�3g
����
���a
���g
�
�
3
�
�
.�
n
9y
�'z
3
�
�
c
c
$
g� R
f" � �
�� �
�� �
���
0
� `� �� 1�` �°�
i..'
JANUARY, 2011 TR I FAB� VG 451 T
EC 97911-25 THERMAL PERFORMANCE MATRIX
TRIFAB� VG 451T (CENTER)
Thermal Transmittance'
SHGC Matrix 2
NOTE: For glass values that are not listed, linear interpolation is permitted.
Visible Transmittance 2
;.
CHARTS
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Giass properties are based on center of gtass values and are obtained from your glass supplier.
4, Overall U-Factor, SHGC, and VT Matricies are based on the sta�dard NFRC specimen size of 2000mm wide by 2000mm high
(7B-3/4' by 78-3/4").
�"`°�' �� KAWNEER
� .
+ , ,
� 32 190/350/500 STANDARD ENTRANCES
�
THERMAL PERFORMANCE MATRIX (NFRC SIZE�
Thermal Transmittance' teTUn,r • ft Z•°F�
Giass U-Factor 3 Overall U-Facto� `
0.47 0.79
0.46 0.78
0.44 0.77
0.42 0.76
0.40 0.75
0.38 0.74
0.36 0.73
0.34 0.72
0.32 0.71
0.30 0.70
0.28 0.69
26 .
0.24 0.67
0.22 0.66
0.20 0.65
0.18 0.64
0.16 0.63
0.14 0.62
0.12 0.61
o. � o o.so
SHGC Matrix 2
Glass SHGC 3 Overaii SHGC `
0.75 0.46
0.70 0.43
0.65 0.40
0.60 0.37
0.55 0.35
0.50 0.32
0.45 0.29
0.40 0.2B
0.35 023
0.30 0.21
0.25 0.18
0.20 0.15
0.15 0.12
0.10 0.09
0.05 0.07
��KAWNEER
.�..�„:�,..�.
- ___
� � �� JUNE 2011
-- - ,
EC 97911-30
350 (PAIR OF DOORS)
NOTE: For giass values that are not listed, linear
interpolation is permitted.
t. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with
NFRC 200.
3. Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier
4. Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1920mm wide by
2090mm high (75-112" by 82-3/8').
Visible Transmittance 2
Giass VT' Overall VT °
0.75 0.42
0.70 0.39
0.65 0.3fi
0.60 0.34
0.55 0.31
0.5� 0.28
0.45 025
0.40 0.22
0.35 0.20
0.30 0.17
025 0.14
0.20 0.1-1
0.15 0.08
0.10 0.06
0.05 0.03
���
�
�a
u `
�E
°�5 m
���
���
� ���
�� �.�
����
�a���
J U � �
�:��3�
��a�
��Y3
�m�m
�
a
�
�
.
s
P
a
�
�
g
�
�
�
8
�� R
g� �
$� �
gg �
�� �
�� �
x O
J�ll-����E
.
onsu ln
Final Clearance Air Monitoring Report
186 E Gore Creek Dr, Vail, Colorado 81657
Presented To:
Mr. Richard Capra
Rocky Mountain Abatement, Inc
P.O. Box 621840
Littleton, CO 80162-1840
Performed & Prepared By:
Mr. Robert E. Kurvink
DS Consulting, Inc.
PO Box 6864
Avon,CO 81620
(720) 292-8979
Project Details:
Project Number: 4862
Conducted: October 18, 2011
CC�C�DMi�
OCT 21 2011
�
OF VAIL
PROJECT SUMMARY
On October 18, 2011, Mr. Robert E. Kurvink with DS Consulting, Inc. (DSC) conducted a final visual
inspection, performed aggressive clearance air monitoring, and analyzed clearance air-quality samples
via Phase Contrast Microscopy (PCM) for an asbestos abatement project within a portion of the
commercial space located at 186 E Gore Creek Dr, Vail, Colorado.
Services were provided at the request of Mr. Richard Capra with Rocky Mountain Abatement, Inc. in
support of asbestos abatement activities being conducted to remove approximately 80ftz of asbestos-
containing plaster from a secondary containment encompassing the front portion of the space.
Monitoring locations and frequencies were determined by Mr. Robert E. Kurvink; having EPA and State of
Colorado accreditation No. 15413. PCM analysis was also performed by Mr. Kurvink (see Appendix B for
certi�cation).
SCOPE OF WORK
Prior to the collection of final clearance air samples, a final visual inspection was conducted to ensure all
of the visual requirements were met. Once the abatement area passed the final visual inspection, DSC
collected final clearance air samples from random locations within the containment. Following the
collection of the final clearance air samples, Mr. Kurvink analyzed the samples - as well as sample blanks -
to determine the airborne fiber concentrations. Mr. Kurvink is NIOSH 582 certified and DSC is a
participant in the Industrial Hygiene Proficiency Analytical Testing (IHPAT) program with laboratory ID
No. 188987 and has a rating of Proficient.
The abatement project passed the final visual inspection and the analytical results of all final clearance
samples collected were below the State of Colorado's clearance criteria of 0.01 fibers/cubic centimeter
(f/cc) (see Appendix A for Air Sample Analysis). This amount, quantified as "fibers", is not specific to
asbestos fibers; therefore, all fibers that meet the counting criteria are counted as asbestos fibers. If the
total fiber count is less than 0.01 fibers/cubic centimeter (f/cc), it is known that the total asbestos fiber
count is also less than 0.01 fibers/cubic centimeter (f/cc)
PROJECT INFORMATION
• General Abatement Contractor (GAC)
Rocky Mountain Abatement, Inc.
• GAC Project Supervisor
Mr. Brian Coughlon
• Project Location
186 E Gore Creek Dr, Vail, Colorado
• Project Contact
Mr. Richard Capra
2
• Air Monitoring Specialist/Analyst
Mr. Robert E. Kurvink
• Date Conducted
October 18, 2011
• Final Clearance Sample Results
See Appendix A
• Certifications
See Appendix B
AIR MONITORING
Air-quality samples were collected utilizing a modified NIOSH 7400 Method, whereby samples were
collected on 25-millimeter (mm) mixed-cellulose, ester-membrane filters with 0.45-micron pore size and
analyzed via Phase Contrast Microscopy (PCM) as per the customer's requirements.
Sample Collection - PCM samples, when applicable, were collected on 25-millimeter (mm) mixed-
cellulose, ester-membrane filters with 0.45-micron pore size with an effective collection area of 385 mm.
All filters were pre-assembled by the manufacturer in three stages, conductive sampling cassettes with
extension cowls.
Air samples were collected at an average flow rate 12.5 liters per minute (L/m) using Thomas high-
volume pumps with a minimum of 1,200 liters being collected. Flow rates were collected at the
beginning and at the end of the sampling period utilizing an airflow rotameter calibrated against a
primary-flow calibration instrument. Start times and stop times were recorded for all sampling periods.
A field blank and lab blank were also collected and analyzed along with the five (5) clearance samples.
PCM Sample Analysis Method - PCM samples were analyzed according to a modified NIOSH 7400
Method—A Counting Rules—although samples were collected on 25-mm mixed-cellulose, ester-
membrane filters with 0.45-micron pore size and analyzed via PCM. Air sample results contained in this
report have been calculated with blank sample corrections.
APPENDIX A- AIR SAMPLE RESULTS
BRL = Below Reporting Limit
3
w
APPENDIX B - AMS/ANALYST CERTIFICATIONS
4
F.�'' �3 � ;�z
C 3 k'
� N � i
[ � � ',...` u
C4� 3�w � F^ ��%
w�,,;,�J��..
t' SS � v '.r
x -�:
! �
:� !
� �
V � `+ i
� `rr
y� ,f �
� Ap :.._
� ?,: fi .�
O m},°jF ..�r�'.
� � ae�
� �E
c
'L i
— ,. �yx:'; '
TQWN 0� VA�t'
Department of Community Development r
75 South Frontage Road
Vail, CO 81657
`� Tel: 970-479-2128
www.vailgov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address: Project #: �
#154
186 East Gore Creek Dnve
(Number) (Street)
(Suite #)
Building/Complex Name: The Lodge at Vail
Contractor Information
Business Name: George Shaeffer Construction Company
' Business Address: PO Box 373
City Vail State: C� Zip: 81658
Contact Name: Travis Cremonese
Contact Phone: 970-790-1510
' Contact E-Mail: travisc@gsconco.com
X �-� �-----
Owner/Owner's Representative Signature (Required)
Applicant Information
' Applicant Name: Travis Cremonese
' Applicant Phone: 970-790-1510
Applicant E-Mail: travisc@goconco.com
DRB #: � � � i�3 3�
Building Permit #: � � �����
Lot #: Block # Subdivision:
Work Class: New ( ) Addition ( ) Alteration ( ✓ )
Type of Building:
Single-Family ( ) Duplex ( ) Multi-Family ( )
Commercial ( ✓ ) Other ( )
Work Type: Interior () Exterior () Both (✓)
_ Valuation of '
Work Included Plans Included Work
Electrical ( ✓ )Yes ( )No ( ✓ )Yes ( )No $7,500
Mechanical ( � )Yes ( )No ( ✓ )Yes ( )No $2,500
Plumbing ( )Yes ( ✓)No ( )Yes (/JNo $�
Building ( � )Yes ( )No ( ✓ )Yes ( )No $90�000
Value of all work being performed: $100,000
(value based on IBC Section 109.3 & IRC Section 108.3)
y . . . ,_ _, : _-:- -
Project Information Tochter LLC � Electrical Square Footage 393 SF
` Owner Name:
_ �___.�_.__�..._. . . _ .. ... _�_ . ._._..._ ._ _. _,. .._ __
'��� Parcel #: 2101-082-21-015 � � � �
J(For Parcel #, contact Eagie County Assessors Office at (970-32&8640 or visit
', www.eaglecounty.us/patie)
, � �� . Interior renovations includin.� �� ���_����� �� � .�. _......�.. .. _. . ..�.-�___ �,�,.._..
Detailed Scope and Location of work: � g removing and repiacing interior finishes, constructing
a small office and storage area in the back of the space, install new storefront glass system. '
(use additional sheet if necessary)
For Office Use Only:
Fee Paid: � iay .9y
Received From: TRAVi � �C�� �wFFF�
Cash Check # I 0 3 g'7 I
CC: Visa / MC Last 4 CC # exp date:
Auth #
__..._ __ __
)ate Received:
OCT o 3 2011
���'_l�,
�;
GEORGE SHAEFFER
CONSTRUCTION COMPANY
P.o. Box 373
VAIL, COLORADO 81658
TO:
Martin Haeberle
Vail Town of
75 South Frontage Road
Vail, CO 81657
Voice #: 970-479-2138
Fax #: 970-479-2452
Email: mhaeberle@vailgov.com
LETTER OOF TRANSMITTAL
WE ARE SENDING YOU ❑Attached ❑Under separate cover via the following items:
❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications
❑ Copy of letter ❑ Change order � Permit Application Submittal
COPIES DATE NO. DESCR[PT[ON
1 10/3/11 Plan Check Fee GSCC Check # 103871
1 10/3/1 1 Permit A lication Form
3 9/30/11 Stam ed Permit Plans
3 9/30/11 COMcheck Worksheet
1 9/12/11 DRB Action Form A roval
THESE ARE TRANSMITTED as checked below:
� For approval
� For your use
❑ As requested
❑ For review and comment
❑ FOR BIDS DUE
❑ Approved as submitted
p Approved as Noted
❑ Returned for corrections
❑
❑ Resubmit
❑ Submit _
❑ Return _
_ copies for approval
copies for distribution
corrected prints
❑ PRINTS RETURNED AFTER LOAN TO US
REMARKS:
Martin,
Please find attached the building permit application submittal for 186 East Gore Creek Dr unit #154. Per your
conversation with Leah Mayer with LKSM Design we will follow up with the asbestos testing report ASAP.
Thanks
Steve
COPY TO:
Job File
/
SIGNED• �\ - �
�
�
George Shaeffer Construction Company
If enclosures are not as noted, kindly notiJy us at once.
Version 1.0
-,, � .
COMcheck Software Version 3.8.2
Interior Lighting and Power
Compliance Certificate
90.1 (2007) Standard
Section 1: Project Information
Project Type: New Construction
Project Title : Skin by Vail Dermatology
Construction Site:
186 E. Gore Creek Drive
Vail, CO
��=r�
�l��`�'��� �.��
A.. �,��a ��LL���,��,
��ilsr�::Y3�.r.
Owner/Agent: Designer/Contractor:
Architectural Engineering Design Group
1900 Wazee Street
Suite #350
Denver. CO
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
�rtz� wans i n2 �a X c>
Retail:Sales Area 296 1.7 503
Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID� F1 66(a) 2.6 172(b)
Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: F2 30(a) 2.6 78(b)
Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: F4a 13(a) 2.6 34(b)
Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: F4b 27(a) 2.6 67(b)
Common Space Types:Office - Enclosed 52 1.1 57
Common Space Types:Active Storage 44 0.8 35
Supplemental Allowed Watts(c) = 306
Total Allowed Watts = 1252
(a) Area claimed must not exceed the illuminated area permitted for this allowance type.
(b) Allowance is (B x C) or the actual wattage of the fixtures given in Section 2, whichever is less.
(c) Supplemental watts must be associated with retail merchandise highlighting fixtures. Supplemental watts are not included
calculation of lighting complaince percentage.
Section 3: Interior Lighting Fixture Schedule
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
Retail:Sales Area (296 sq.ft.)
Compact Fluorescent 1: F1: 6" CFL Dwnlight / Triple 4-pin 32W / Electronic
LED 1: F2: LED Accent / Other / Electronic
LED 3: F6: LED Puck Light / Other / Electronic
Compact Fluorescent 2: F3: Decorative Pendant / Twin Tube 18W / Electronic
LED 2: F4a: LED Strip / Other ! Electronic
LED 2: F4b: LED Strip / Other / Electronic
Common Space Types:Office - Enclosed (52 sq.ft.)
Compact Fluorescent 3: F1: 6" CFL Dwnlight / Triple 4-pin 32W / Electronic
Common Space Types:Active Storage (44 sq.ft.)
Linear Fluorescent 1: F5: Fluor Strip Light / 48" T8 32W / Electronic
Section 4: Requirements Checklist
Lighting Wattage:
B C D E
Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
1 12 35 420
1 14 12 168
1 48 4 192
4 3 78 234
1 1 34 34
1 1 67 67
1 3 35 105
1 1 32 32
Total Proposed Watts = 1252
Project Title: Skin by Vail Dermatology
Data filename: J:�2094.00 - Vail Skin IECC\Ltg Calcs\Skin by Vail Dermatology_LED Puck.cck
Report date: 09/29/11
Page 1 of 2
�
0 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Watts Proposed Watts Complies
1252 1252 Passes using retail merchandise highlighting supplemental watts.
� 2. Exit signs 5 Watts or less per sign.
Controls, Switching, and Wiring:
0 3. Independent manual or occupancy sensing controls for each space (remote switch with indicator allowed for safety or security).
� 4. Occupant sensing control in class rooms, conference/meeting rooms, and employee lunch and break rooms.
Exceptions:
❑ Spaces with multi-scene control; shop classrooms, laboratory classrooms, and preschool through 12th grade classrooms.
� 5. Automatic shutoff control for lighting in >5000 sq.ft buildings by time-of-day device, occupant sensor, or other automatic control.
Exceptions:
� 24 hour operation lighting; patient care areas; where auto shutoff would endanger safety or security.
� 6. Master switch at entry to hotel/motel guest room.
0 7. Separate control device for display/accent lighting, case lighting, task lighting, nonvisual lighting, lighting for sale, and demonstration
lighting.
� 8. Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts).
Exceptions:
� Electronic high-frequency ballasts.
� Luminaires not on same switch.
� Recessed luminaires 10 ft. apart or surtace/pendant not continuous.
❑ Luminaires on emergency circuits.
Voltage Drop:
� 9. Feeder conductors have been designed for a maximum voltage drop of 2 percent.
0 10. Branch circuit conductors have been designed for a maximum voltage drop of 3 percent.
_ . . . . . . .. -
Section 5: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and
other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 90.1 (2007) Standard
requirements in COMcheck Version 3.8.2 and to comply with the mandatory requirements in the Requirements Checklist.
Jeff Mullikin P.E. � "���`��
,..;
J�' . o., "����Hm 9-30-11
Name - Title Signature Date
Section 6: Post Construction Compliance Statement
Record Drawings and Operating and Maintenance Manuals:
� 1. Construction documents with record drawings and operating and maintenance manuals provided to the owner.
Lighting Designer or Contractor Name Signature Date
��u
�(J� 34d � ~�. �
�..1�� �l ..�; �
��sic�a�L`�
Project Title: Skin by Vail Dermatology Report date: 09/29/11
Data filename: J:�2094.00 - Vail Skin IECC\Ltg Calcs\Skin by Vail Dermatology_LED Puck.cck Page 2 of 2
■
�l�1Sl� 1�1
Asbestos Inspection and Sampling Report
186 E Gore Creek Dr, Vail, Colorado 81657
Presented To:
Ms. Leah KS Mayer
LKSM Design
PO Box 9195
Avon, CO 81620
Performed & Prepared By:
Mr. Robert E. Kurvink
DS Consulting, Inc.
PO Box 6864
Avon, CO 81620
(720) 292-8979
Project Details:
Project Number: 4811
Conducted: September 28, 2011
EXECUTIVE SUMMARY
On September 28, 2011, Mr. Robert E. Kurvink with DS Consulting, Inc. (DSC) performed a limited
asbestos inspection and performed asbestos bulk-sampling within the commercial space located at 186 E
Gore Creek Dr, Vail, Colorado in order to identify potentially hazardous friable and non-friable asbestos-
containing materials (ACM) prior to an upcoming remodel. The Colorado Department of Public Health
and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material (ACM) as a
material containing more than 1% asbestos.
Mr. Kurvink collected a total of seven asbestos bulk-samples of two different types of drywall surfacing
textures as well as a single type of carpet/glue. The drywall surfacing texture found on the dividing walls
within the unit is a light knockdown texture; the drywall surfacing texture found on the front wall of the
space is a heavy knockdown. The carpet was found throughout the space.
All seven bulk-samples were analyzed by a National Voluntary Laboratory Accreditation Program
(NVLAP) accredited lab in Denver, Colorado. The heavy knockdown drywall surfacing texture found
on the front wall of the space contains 3% Chrysotile asbestos. The light knockdown drywall
surfacing texture found on the dividing walls as well as the carpet/glue is none-detect.
The following bulk-samples reported positive for asbestos greater than 1% Chrysotile and therefore are
asbestos-containing materials (ACM) -(see Appendix B for laboratory report):
� �
i � � � � �
Heavy Knockdown Surfacing 3%
DW2-1 Drywall Surfacing Front Wall Material Friable ±120ft2 Good Chrysotile
Texture
Heavy Knockdown Surfacing 3%
DW2-2 Drywall Surfacing Front Wall Material Friable ±120ft2 Good Chrysotile
Texture
Heavy Knockdown Surfacing 4%
DW2-3 Drywall Surfacing Front Wall Material Friable ±120ft2 Good Chrysotile
Texture
*The quantities of materials listed in this report are general approximations used specifically to determine the
number of bulk-samples of each material to be collected. These quantities should not be used for any other purpose.
On-site verification of the exact quantity of material is required for bidding purposes.
2
PROJECT OVERVIEW
I. Introduction
A limited asbestos inspection and bulk-sampling for ACM was conducted within the commercial space
located at 186 E Gore Creek Dr, Vail, Colorado, by Mr. Kurvink on September 28, 2011 at the request of
Ms. Leah Mayer with LKSM Design. Mr. Kurvink is a Colorado State Certified Building Inspector; having
EPA Accreditation #9440 -(see Appendix A for certificate). The purpose of the inspection was to identify,
sample and assess potentially hazardous friable and non-friable ACM within portions of the space that
may be impacted by remodeling activities.
II. Structural Design
The space is a single room commercial store front.
III. Sampling and Analytical Procedures
The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building
Inspector qualified by experience, education and training in the recognition of potential ACM and
approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a
limited number of bulk-samples being collected within the space.
The inspection, assessment and sampling were performed in accordance with Environmental Protection
Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of
concern and the collection and analysis of representative bulk-samples of suspect material.
Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not
broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be
located in these and other inaccessible areas.
Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of
each homogeneous area (HA), were collected according to the guidelines published as Environmental
Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections
2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the
following criteria:
1. The distribution of the suspect material throughout the HA.
2. The suspect material's physical characteristics and application.
3. Random sampling patterns determined for each HA.
Suspect materials sampled and analyzed should be considered to be representative of materials in each
HA if they exhibit similar physical characteristics and the application of the sampled material can be
correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the
EPA's Method for the Determination ofAsbestos in Bulk Buildina Materials (EPA 600/R/116, July, 1993)
and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the
bulk-samples was performed on the "date reported," as listed in the bulk-sample analysis report.
3
IV. Notes on Report Format
Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were
divided into three classifications:
1. Surfacing Material: sprayed or troweled onto structural building member.
2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation.
3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles,
insulation, and finishing materials.
Condition assessments were performed by the accredited inspector at the time of inspection. Condition
assessments are listed in the following section. Ratings of "good," "damaged," and "significantly
damaged" are meant to indicate the overall condition of the material.
A material in "good" condition has no visible damage or deterioration, or showing only very limited
damage or deterioration. A material in "damaged" condition has the following characteristics: The
surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-
tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized).
Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces
beneath the material can be used as confirmatory evidence. A material in "significantly damaged"
condition has one or more of the following characteristics:
• The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized).
• One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or
showing adhesive failure.
• Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris
similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence.
Response-action recommendations for asbestos-containing HAs are listed in the section VII.
Recommendations may be for more than one HA, if materials are alike. Recommendations are either
"general" or "immediate." An immediate recommendation indicates the presence of asbestos greater
than 1% within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly.
A general recommendation indicates asbestos does not exist greater than 1% within the bulk-sample, or
all bulk-samples in the same HA, and no further abatement activities are required for removal of the
material. Any sample reporting a"TRACE" amount of asbestos must be considered to be positive for
asbestos greater than 1% unless it is analyzed by the point-count method to be less than 1%.
V. Inspector Comments
Asbestos-containing material was identified during the bulk-sampling conducted within the commercial
space located at 186 E Gore Creek Dr, Vail, Colorado. A total of seven bulk-samples of two types of
drywall surfacing textures and a single type of carpet/glue were collected from the main room of the
store. The heavy knockdown drywall surfacing texture on the front wall of the space is positive for
asbestos greater than 1%.
�
VI. Homogeneous Area Descriptions
The following section contains sampled HA descriptions and sample locations. Percent-asbestos content
for each sample indicated can vary depending on sample locations, homogeneity of the materials, and
type of application. The quantities are approximations and are subject to field verification. ND=None-
detect; CHRY=Chrysotile; TR=Trace (<1% Visual Estimate).
��. .� � I � ��. .� . �
Sample #: DW1-1 Sample #: DW1-2
Sample Description: Light Knockdown Drywall Sample Description: Light Knockdown Drywall
Surfacin Texture Surfacin Texture
Sample Location: First Dividing Wall on Left Sample Location: Third Dividing Wall on right
Material Classification: Surfacing Material Material Classification: Surfacing Material
Estimated Material Quantity Impacted: ±250ftz Estimated Material Quantity Impacted: ±250ftz
Material Condition: Good Material Condition: Good
Material Friability: Friable Material Friability: Friable
Layers - Asbestos Content: Layers - Asbestos Content:
White/Tan Drywall - ND White Texture w/Red Paint - ND
White Compound - ND White Compound - ND
White Tan Dr all - ND
Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII
� ��. .� � 1 � ��. .� . �
Sample #: DW1-3 Sample #: DW2-1
Sample Description: Light Knockdown Drywall Sample Description: Heavy Knockdown Drywall
Surfacin Texture Surfacin Texture
Sample Location: Fourth Dividing Wall on right Sample Location: Front Wall Between Window &
Entr
Material Classification: Surfacing Material Material Classification: Surfacing Material
Estimated Material Quantity: ±250ftz Estimated Material Quantity: ±120ftz
Material Condition: Good Material Condition: Good
Material Friability: Friable Material Friability: Friable
Layers - Asbestos Content: Layers - Asbestos Content:
White Resinous w/Red Paint - ND Red/Purple Paint - ND
White/Tan Drywall - ND White Tape - ND
White Texture - 3% CHRY
White Joint Compound - 3% CHRY
White Tan Dr all - ND
Recommendations: GENERAL - See Section VII Recommendations: IMMEDIATE - See Section VII
1 1'• •1 � � 1 1'• •1 � �
Sample #: DW2-2 Sample #: DW2-3
Sample Description: Heavy Knockdown Drywall Sample Description: Heavy Knockdown Drywall
Surfacin Texture Surfacin Texture
Sample Location: Front Wall Between Window & Sample Location: Front Wall Between Window &
Entr Entr
Material Classification: Surfacing Material Material Classification: Surfacing Material
Estimated Material Quantity: ±120ftz Estimated Material Quantity: ±120ftz
Material Condition: Good Material Condition: Good
Material Friability: Friable Material Friability: Friable
Layers - Asbestos Content: Layers - Asbestos Content:
Red/Multi-Colored Paint - ND Red/Multi-Colored Paint - ND
White Tape - ND White Texture - 4% CHRY
White Texture - 3% CHRY White/Tan Drywall - ND
White Joint Compound - 3% CHRY
White Tan Dr all - ND
Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII
� ��. .� . �
Sample #: CA1-1
Sample Description: Carpet/Glue
Sample Location: Between Third & Fourth Right
Dividin Walls
Material Classification: Miscellaneous Material
Estimated Material Quantity Impacted: ±300ftz
Material Condition: Good
Material Friability: Non-Friable
Layers - Asbestos Content:
Orange Resinous Material - ND
White Fibrous Material - ND
Pur le Foam - ND
Recommendations: GENERAL - See Section VII
VII. Recommendations
IMMEDIATE: The laboratory results of the potential ACM sampled within the commercial space located
at 186 E Gore Creek Dr, Vail, Colorado, on September 28, 2011, indicate that the drywall surfacing texture
found on the main room front wall between the window and entry reported positive for asbestos at 3-4%
Chrysotile.
If the above-referenced ACM is to be removed from the space and the total quantity exceeds any of the
regulatory trigger levels of 260ft on pipes, 160ftz on other surfaces, or the volume equivalent of a 55-
gallon drum, a Colorado-licensed asbestos General Abatement Contractor (GAC) is required to perform
the removal, including formal notification to the Colorado Department of Public Health and Environment
prior to the abatement of the ACM.
�
DISCLAIMER AND LIMITATIONS
DSC performed the activities included in this report in a manner consistent with the level of care and
expertise exercised by members of the environmental consulting profession. DSC performed all activities
in accordance with all applicable federal, state, and local regulations, generally accepted standards and
professional practice. No warranty is either expressed or implied. DSC assumes no responsibility or
liability for error in public information utilized, statements from sources other than DSC, or
developments resulting from situations outside the scope of this project.
This report and the details provided within outline the inspection activities on the date(s) indicated, the
limited number of bulk-samples collected, and the laboratory results of those bulk-samples. The
laboratory results contained in this report apply specifically to the materials in which bulk-samples were
collected. The results do not include or apply to any other materials within the structure that were not
sampled but may contain asbestos. Additional inspection and bulk-sampling activities would be required
to determine if any other materials contain asbestos.
The information contained in this report is intended as supplementary material and is NOT to be used as
the scope of work for abatement activities. DSC can provide a full scope of work for abatement upon
request.
The results of any surfacing material indicated in this report also include any associated overspray with
that material, e.g., under carpet, above suspended ceilings, etc.
7
APPENDIX A - INSPECTOR CERTIFICATION
, � . , �:i ;;� .� ;� ,:� �' .
,� "��," '�y,.�`' '� �'� __ `'� .P'" . _ '� 1"_" _ '�""':: �►.�*` _ vr�
,�` �
= �ff�t« '�::, STATE OF COLOR.ADO
�;-:
_���'° ASBESTOS
;!'K��. I„-
� CERTIFICATION*
-,.::�'F'
� C'olorado Depariment uf Puhlic Healih
, � � and Ettvirnnmenl
'�- Air Aolluiion Cnnuol Dirision
.:,=- iE,,.
;;;�`; i�__.
�` "I'his certifies that
__ �� E
- �=�"�� " Robert E Kurvink
2.
,
� CertiGcation Nu: 94d0
: rj. .�,�'��
''f �i:+ i�,
�>;, ' has met the requirements of 25-7-507, C.R.S. and Air Quali[y Conlrul
? Ci�mmissian Regulation No. 8, Part B, a��d is hercby ccrtitic�l hy ihr
�J�"' staie of C'ulorldo in Che following disciplin�:
— «� 1�::.
_ ��;� {f:�
j�...
-= Building Inspector*
i+su��: iuzxrzoio
F;xpires on: 12128I2011 ?
�I�,�7�r�r�'
APPENDIX B - LABORATORY REPORT
:
�
�
R E I LA6 R�servo►rs En viro�m�� �a►, In�_
OCtober 3, 2011 Laboratory Code: RES
Subcontract Number: NA
Laboratory Report: RES 221587-1
Project #/ P.O. # 186 Gore Creek Vail
Project Description: None Given
DS Consulting, Inc.
5366 Flatrock Ct.
Morrison CO 80465
Dear Customer,
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene
and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab
Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM)
analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate
#480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both
Proficiency Testing and PAT programs respectively.
Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your
request. The analysis has been completed in general accordance with the appropriate methodology as
stated in the attached analysis table. The results have been submitted to your office.
RES 221587-1 is the job number assigned to this study. This report is considered highly confidential
and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study
with personnel other than those of the client. The results described in this report only apply to the samples
analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or
any agency of the U.S. Government. This report shall not be reproduced except in full, without written
approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer
storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
Sincerely,
�«_ _—��
Jeanne Spencer Orr
President
� ��
Analyst(s): �
Paul D. LoScalzo Wenlong Liu
Michael Scales Adam Humphreys
Anita Grigg Robert R. Workman Jr.
Bethany Nichols Anya Angst
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Page 1 of 3
1-866-RES I-ENV
www.reilab.com
RESERVOIRS ENVIRONMENTAL, INC.
NVLAP Lab Code 101896-0
TDH Licensed Laboratory # 30-0136
TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
RES Job Number:
Client:
Client Project Number/ P.O.
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Analyzed:
RES 221587-1
DS Consulting, Inc.
186 Gore Creek Vail
None Given
September 29, 2011
PLM,Short Report
48 Hour
October 1, 2011
Page 2 of 3
Client Lab L Asbestos Content Non Non-
Sample ID Number A Sub Asbestos Fibrous
Number Y Physical Part � Fibrous Components
E Description (%) Mineral � visuai omponents (%)
R ; Estimate (% (%)
DW1-1 EM 802952 A White/tan drywall 40 ND 12 88
B White compound w/ red paint 60 ND 0 100
DW1-2 EM 802953 A White texture w/ red paint 5 ND 0 100
B White compound 15 ND 0 100
C White/tan drywall 80 ND 15 85
DW1-3 EM 802954 A White resinous w/ red paint 10 ND 0 100
B White/tan drywall 90 ND 15 85
DW2-1 EM 802955 A Red/purple paint 5 ND 0 100
B White tape 5 ND 95 5
C White texture 10 Chrysotile 3 0 97
D White joint compound 10 Chrysotile 3 0 97
E White/tan drywall 70 ND 20 80
DW2-2 EM 802956 A Red/multi-colored paint 2 ND 0 100
B White tape 3 ND 95 5
C White texture 5 Chrysotile 3 0 97
D White joint compound 10 Chrysotile 3 0 97
E White/tan drywall 80 ND 15 85
DW2-3 EM 802957 A Red/multi-colored paint 3 ND 0 100
B White texture 7 Chrysotile 4 0 96
C White/tan d wall 90 ND 15 85
ND=None Detected
TR=Trace, Q % Visual Estimate
Trem-AcrTremolite-Actinolite
Note: Further analysis by TEM is recommended for organically bound material (i. e. floor tile)
if PLM results are Q%.
Data QA
RESERVOIRS ENVIRONMENTAL, INC.
NVLAP Lab Code 101896-0
TDH Licensed Laboratory # 30-0136
TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
RES Job Number:
Client:
Client Project Number/ P.O.
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Analyzed:
RES 221587-1
DS Consulting, Inc.
186 Gore Creek Vail
None Given
September 29, 2011
PLM,Short Report
48 Hour
October 1, 2011
Page 3 of 3
Client Lab L Asbestos Content Non Non-
Sample ID Number A Sub Asbestos Fibrous
Number Y Physical Part � Fibrous Components
E Description (%) Mineral � visuai omponents (%)
R ; Estimate (% (%)
CA1-1 EM 802958 A Orange resinous material 2 ND 0 100
B White fibrous material 8 ND 95 5
C Purple foam 90 ND 0 100
ND=None Detected
TR=Trace, Q % Visual Estimate
Trem-AcrTremolite-Actinolite
Note: Further analysis by TEM is recommended for organically bound material (i. e. floor tile)
if PLM results are Q%.
Data QA
0
12-09-2011
Inspection Request Re
v��i r_n _ r_�t" n
Requested Inspect Date: Monday December 12, 2011
Site Address: 186 GORE CREEK DR VAIL
LODGE AT VAIL - UNIT 154
Page 6
A/P/D Information
Activity: 611-0404 Type: COMBO Sub Type: ACOM Status: ISSUED
Const Type: Occupancy: Use: M Insp Area:
Owner: TOCHTER LLC
Contractor: EVANS CHAFFEE CONSTRUCTION GROUP Phone: 970-845-0466
Description: INTERIOR RENOVATIONS INCLUDING REMOVING AND REPLACING INTERIOR FINISHES,
CONSTRUCTING A SMALL OFFICE AND STORAGE AREA IN THE BACK OF THE SPACE. INSTALL
NEW STOREFRONT GLASS SYSTEM.
Requested Inspection(s)
Item: 390 MECH-Final
Requestor:
Comments: 904-0454
Assigned To: ON
Action:
r �
f ��.
� � � ��
Inspection Historv
Item: 120 ELEC-Rough
11/14/11 Inspector:
Comment: wafls only
12/05/11 Inspector:
Comment:
Item: 200 MECH-Rough
11 /17/11 Inspector:
Comment:
Item: 30 BLDG-Framing
11/14/11 Inspector:
Comment: walls only
11/17/11 Inspector:
Comment:
Item: 50 BLDG-Insulation
11/17/11 Inspector:
Comment:
Item: 60 BLDG-Sheetrock Nail
11/17/11 Inspector:
Comment: walls
12/02/11 Inspector:
Comment:
Item: 190 ELEC-Final
Item: 390 MECH-Final
Item: 90 BLDG-Final
Item: 542 PLAN-FINAL
Time Exp:
"' Approved ""
sgremmer
sgremmer
** Approved "*
sgremmer
** Approved *"
sgremmer
sgremmer
"* Approved "
sgremmer
"* Approved ""
sgremmer
JRM
Requested Time: 08:00 AM
Phone:
Entered By: MHAEBERLE K
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
Action: AP APPROVED
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
Action: AP APPROVED
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
REPT131 Run Id: 13860
--- - —_-- -- — - ,
12-12-2011 Inspection Request Re orting Page 11
_4:2g �m -_- Vail, CO ,�it�[-�------ �•[1� � �
Requested Inspect Date: Tuesday December 13, 2011
Site Address: 186 GOR�E CREEK DR VAIL
LODGE AT VAIL - UNIT 154
A/P/D Information
Activity: 611-0404 Type: COMBO Sub Type: ACOM Status: ISSUED
Const Type: Occupancy: Use: M Insp Area:
Owner: TOCHTER LLC
Contractor: EVANS CHAFFEE CONSTRUCTION GROUP Phone: 970-845-0466
INC
Description: INTERIOR RENOVATIONS INCLUDING REMOVING AND REPLACING INTERIOR FINISHES,
CONSTRUCTING A SMALL OFFICE AND STORAGE AREA IN THE BACK OF THE SPACE. INSTALL
NEW STOREFRONT GLASS SYSTEM.
Requested Inspection(s)
Item: 190 ELEC-Final
Requestor: INV�ANS CHAFFEE CONSTRUCTION GROUP
Comments: 376-4313
Assigned To: AGON
Action: Time Exp:
/z�3il
Inspection History
Item: 120 ELEC-Rough "` Approved �'
11/14/1'f Inspector: sgremmer
Comment: wafls only
12/05/11 Inspector: sgremmer
Comment:
Item: 200 MECH-Rough "`� Approved *"
11/17/11 Inspector: sgremmer
Comment:
Item: 30 BLDG-Framing ""` Approved "'
11/14/11 Inspector: sgremmer
Comment: wafls only
11/17/11 Inspector: sgremmer
Comment: .
Item: 50 BLDG-Insulation "" Approved "*
11/17/11 Inspector: sgremmer
Comment:
Item: 60 BLDG-Sheetrock Nail "" Approved "`
11/17/11 Inspector: sgremmer
Comment: wafls
12/02/11 Inspector: JRM
Comment:
Item: 190 ELEGFinal
Item: 390 MECH-Final
Item: 90 BLDG-Final
Item: 542 PLAN-FINAL
Requested Time: 03:30 PM
Phone: 970-845-0466
Entered By: JMONDRAGON K
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
Action: AP APPROVED
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
Action: AP APPROVED
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
REPT131 Run Id: 13888
,
i f�-
1
12-14-2011 Inspection Request Re orting � Page 10
4:34 pm _ Vail, CO - Citv O� �'S}��-C�l�
Requested Inspect Date: Thursday December 15, 2011
Site Address: 186 GORE CREEK DR VAIL
LODGE AT VAIL - UNIT 154
A/P/D Information
Activity: B11-0404 Type: COMBO Sub Type: ACOM Status: ISSUED
Const Type: Occupancy: Use: M Insp Area:
Owner: TOCHTER LLC
Contractor: EVANS CHAFFEE CONSTRUCTION GROUP Phone: 970-845-0466
INC
Description: INTERIOR RENOVATIONS INCLUDING REMOVING AND REPLACING INTERIOR FINISHES,
CONSTRUCTING A SMALL OFFICE AND STORAGE AREA IN THE BACK OF THE SPACE. INSTALL
NEW STOREFRONT GLASS SYSTEM.
Requested Inspection(s)
Item: 542 PLAN-FINAL
Requestor: INV�ANS CHAFFEE CONSTRUCTION GROUP
Comments: 904-0454
Assigned To: BGIBSON
Action: Time Exp:
Item: 90 BLDG-Final
Requestor: EVANS CHAFFEE CONSTRUCTION GROUP
INC
Comments: - 454
Assigned To: O�Fj N
Action C Time Exp:
Requested Time: 08:00 AM
Phone: 970-845-0466
Entered By: JMONDRAGON K
Requested Time: 03:00 PM
Phone: 970-845-0466
Entered By: JMONDRAGON K
�
�� ���� . � `� � ���
� �
� �y
,�
�� � ' �������� ��'� c'�i �
�� �����
�
� �
� , �Q �� O /SS�"%
� �O �C'�' ,;� �r�l� ��� �
Inspection History�
Item: 120 ELEC-Rough "' Approved "'
11/14/1 T Inspector: sgremmer Action: PI PARTIAL INSPECTION
Comment: walls only
12/05/11 I nspector:
Comment:
Item: 200 MECH-Rough
11/17/11 Inspector:
Comment:
Item: 30 BLDG-Framing
11/14/11 Inspector:
Comment: wafls only
11/17/11 Inspector:
Comment:
Item: 50 BLDG-Insulation
11 /17/11 Inspector:
Comment:
Item: 60 BLDG-Sheetrock Nail
11/17/11 Inspector:
Comment: walls
12/02/11 Inspector:
Comment:
Item: 190 ELEC-Final
12/14/11 Inspector:
Comment:
Item: 390 MECH-Final
12/13/11 Inspector:
REPT131
sgremmer
"" Approved '*
sgremmer
"� Approved *"
sgremmer
sgremmer
"" Approved "'
sgremmer
" Approved ""
sgremmer
JRM
** Approved "
sgremmer
** Approved "`
sgremmer
Action: AP APPROVED
Action: AP APPROVED
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
Action: AP APPROVED
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
_ _ _
Run Id: 13895