Loading...
HomeMy WebLinkAboutB11-0414 NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES . .y �c��oeu�; . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0414 Project #: PRJ11-0607 Job Address: 4507 MEADOW DR VAIL Applied.....: 10/07/2011 Location......: SUNWOOD CONDOS UNIT B1 Issued. . . : 10/07/2011 Parcel No....: 210112425007 OWNER KING,STEVEN C. &MELISSA H. 10/07/2011 5406 BROOKSIDE CT DOYLESTOWN PA 18902 CONTRACTOR LMS CONSTRUCTION 10/07/2011 Phone: 970-393-2163 PO BOX 3497 VAIL CO 81658 License: C000003348 APPLICANT LMS TILE&CONSTRUCTION 10/07/2011 Phone:970-845-5030 PO BOX 3497 VAIL CO 81658 License: 1013-B Description: KITCHEN AND BATHROOM(TWO)REMODEL.NEW DOORS,BASE AND CASE,NEW TILE FLOOR, NEW WOOD FLOOR.REPLACE BATH FIXTURES AND VALVES. Occupancy: Type Construction: Valuation: $24,000.00 .............................,,...,...,,.,.................,......,................« FEE SUMMARY .......,....,,�....,.........,..,.............,,....,..................,.......... Building Permit-----------> $377.25 Bldg Plan Check----------> $245.21 Use Tax Fee-----------------------> $280.00 Electrical Permit---------> $115.00 Elec Plan Check-----------> $74.75 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $30.00 Plmb Plan Check---------> $7.50 Recreation Fee--------------------> $0.00 Investigation-----------------------> $608.50 Will Call------------------------------> $15.00 TOTAL PERMIT FEES-------------> $1,984.46 Payments------------------------------> $1,984.46 BALANCE DUE-----------------------> $0.00 ............................>.....,........,,.«....._........,....,.............,..,..,............................,,..,.,,.,,.......................,�.......,........».,.........,..... DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE Y TE EPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM-4:00 M. Signatu e of Owner or C�or Da e �.-P� S-��f a�--� Print Name combination permit_012811 t ......' �� , � ������ � ....w.....ee:..ew......x,r......x.e....x..w..+.x.x�.++xxx:�x�.�xxxxxxx.x..x........�....re,r......a....e.+.+.x.+xx..x.xxx.+wx.x....w.......e.xxxxxxxw�r.+x.•......e.....xx...xw......... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 611-0414 Address: 4507 MEADOW DR VAIL Owner: KING, STEVEN C. & MELISSA H. Location: SUNWOOD CONDOS UNIT 61 ...........................................>...,,..,......».,.,.......,...�...,,,...x.,,..,..,...,........,......,.,,,.......,.«.........,,.........,.,......,,....,................, combination permit_012811 f � �I����� i ,r***tr*t*t**�****r*tr*t**r,t*,t***r***********,t,t****�***trt+r*trter,r*,t****+*+r****trtrttr t*,t*,rtnt*****www****+*tttr***tr**,ttr*,t*w,t,t*tttrtrr**xr,rw,t*+t*ve*+rr**rr,t**,r,rwx,t REQUIRED INSPECTIONS AND STATUSES Permit#: B11-0414 Address: 4507 MEADOW DR VAIL Owner: KING, STEVEN C. & MELISSA H. Location: SUNWOOD CONDOS UNIT B1 �.******,,,,**,�**„�**�,.************««*«******«*«.*********.*.*********.,**,,*..***************,*************„«„**«*************«***********«**«*«�*****«* Item: 00120 ELEC-Rough Item: 00220 PLMB-Rough/D.W.V. Item: 00230 PLMB-Rough/Water Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00290 PLMB-Final Item: 00190 ELEC-Final Item: 00090 BLDG-Final combination permit_012811 **********************�*****************************************************++***********+** TOWN OF VAIL, COLORADO Statement **********+*******++********�*****++****************************�*****++++********+++******* Statement Number: R110001426 Amount: $1, 739.25 10/07/201101:59 PM Payment Method: Check Init: SAB Notation: 0173 - LMS CONSTRUCTION ----------------------------------------------------------------------------- Permit No: B11-0414 Type: COMBINATION BLDG PERMIT Parcel No: 2101-124-2500-7 Site Address: 4507 MEADOW DR VAIL Location: SUNWOOD CONDOS UNIT B1 Total Fees: $1, 984 .46 This Payment: $1, 739.25 Total ALL Pmts: $1, 984 .46 Balance: $0. 00 ************+******************************************************************************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 377.25 EP 00100003111100 ELECTRICAL PERMIT FEES 115.00 PF 00100003112300 PLAN CHECK FEES 82 .25 PN 00100003153000 INVESTIGATION FEE (BLDG) 839.75 PP 00100003111100 PLUMBING PERMIT FEES 30. 00 UT 11000003106000 USE TAX 4� 280.00 WC 00100003112800 WILL CALL INSPECTION FEE 15.00 ----------------------------------------------------------------------------- B11-0414 : Entries for Item:90 - BLDG-Final 14:03 01/03/2014 Action Comments By Date Unique_ Ke AP sgremmer 11/30/2011 A000147 112 Total Rows: 1 Page 1 3� Department of Community Development � � 75 South Frontage Road TOWN 0� VAIL ' va�i, CO 81657 Tel: 970-479-2128 � www.vailgov.com 1�� Development Review Coordinator � / ' � ����� � BUILDlNG PERMIT APPLICATION (Separate applications are required for alarm &sprinkler) Project Street Address: Project#: �/�S� � - (���� �.: �l� �1-e�,c�0� D( ��� (Number) (Street) (Suite#) DRB#: '-� - Building/Complex Name: 7U/1 WOC1� Building Permit#:_ Contractor Information��� Lot#: Block# Subdivision: L 1�� � ��n S�-rv C �v�l ---__ _ _ __ ----- __ ___ _________. Business Name: � ` , � �D� �y � � Work Class: New( ) Addition( ) Alteration(�� Business Address: City \f�/�, � State:_��Zip:_� Type of Building: � � Single-Family� Duplex( �Multi-Family( � Contact Name: � " � �"����y �-�r � Commercial( ) Other( ) Contact Phone: �-]l� ` 6 � �� Z� �L� r ! Work Type: Interior(� Exterior( ) Both ( ) i Contact E-Mail: l�.�l�o n�-r'V(;��n/3 3']�_ G'"�`i' � CO►''"` Valuation of X Work Included Plans Included Work Owner/ wner's Representative Signature(Required) Electrical (�Yes ( )No ( )Yes ( )No '17 LZ-- Applicant Information Mechanical ( )Yes ( )No ( )Yes ( )No - Applicant Name: �c }-Q�V�"�-�` Plumbing (�Yes ( )No ( )Yes ( )No � � Building (�)Yes ( )No ( )Yes ( )No - b �� � Applicant Phone: C(�G��i� �- Z� '"� � Applicant E-Mail: Value of all work being performed: $ �value based on IBC Section 109.3�IRC Section 108.3� Project Information `' Electrical Square Footage �K. Owner Name: 1� �n q �i(;�,Q,vl,�,l, arcel#: ��C� ` Z� d�� or P ,contact Eagle County Assessors O�ce at(970-328-8640 or visit www.eaglecounty.uslpatie) --• --— �__�,_:_._.____� ._ __------._._ _... Detailed Scope and Location of W ork: �a- ('�t C��, �1/t) (� �(/►�h(-UT1}�'� !`Q,y►')U � �..Q;�� �(��'(` S f J�S�—�1��.�('Jn�k.�l'1,`e,�J -�-,� � ��OU� ! �:t,✓ ttioo� �loo� ,fZ.�nl c�c.� P�c,��-�-- ��Y�I-�rt� G� �/_ G� !(use additional sheet if necessary) i For Office Use Only: Date Received: Fee Paid: ���•Z � D Received From: U'Ll S (_.'w-i�'���-t�v�-• l�f"�- �C� 0 5 2011 Cash Check # v t � CC: Visa / MC Last 4 CC # exp date: T�WN OF VAIL Auth # O 1-Jan-11 � . ��IVQ�`VA1I,''` BUILDING PERMIT SUBMITTAL REQUIREMENTS Residential condominium remodels/additions (multifamily IBC buildinqs) ***Return this form with your application*** �ets of plans required to be submitted `�( (� Supply DRB application number(i.e. DR6090001) or copy of DRB Action Form �rchitect stamp required on architectural plans. Architect or Engineer's stamp is required on structural, mechanical, plumbing and electrical plans. Remodel projects not disturbing fire resistive construction within the building may not require stamped plans please contact TOV Building Department staff with any questions. ❑ Building construction type, occupancy, fire sprinkler/alarm information and code analysis for existing building shall be included on the plans. ,o/ Asbestos project checklist&testing results � ��'l.9"1^�Z� ❑ Include a key plan showing location of the unit within the building complex. Show location of all existing or proposed exit doors, corridors or stairways from the unit or building. ry Floor plans for the unit showing all proposed work. Clearly show new, existing and demolished walls. Indicate wall assembly types (wood or steel studs) �� Include a door schedule for any new doors. Include information on fire rating as required ❑ Fire rating assembly details for floor/ceiling or roof/ceiling and fire rated walls required. ❑ Fire rating details for recessed light fixtures if lighting is located in a fire rated ceiling. t� For additions, include energy code compliance forms (COMcheck or REScheck) �` http://www.enerqycodes.qov ❑ Structural plans for any proposed structural work. (stamped and signed by architect or engineer) �� Mechanical plans required for all proposed mechanical work. Bath fans, dryer duct, kitchen exhaust, �HVAC ducts and any heating or cooling equipment. Show fire dampers as required on ductwork ptans. (stamped and signed by engineer or architect) �� Plumbing plans for all proposed plumbing work. Include gas piping and sizing plan, drain/waste/vent and water piping. (stamped and signed by engineer or architect) o�Electrical plans for all proposed work. Include electrical power and lighting plans, panel schedule and load calculations. (stamped and signed by engineer or architect) .�_,�,..'�,'�-�_ S t^_o-�,t,s� cJ,� `";'�'�— � c;�--� NOTES: � F:\CDev\BUILDING\checklists\Condominium remodel 022410.doc � � . . ' i i ■ _... onsu ln Asbestos Inspection and Sampling Report 4596 Meadow Dr. in Vail, Colorado 81657 Presented To: Mr. Lee Sedota LMS Construction,Ltd. LMSconstruction337@gmail.com Cell: 970-393-2163 Fax: 970-845-5030 Performed&Prepared By: Mr. Brandon Sinkbeil DS Consulting, Inc. PO Box 6864 Avon,CO 81620 Cell: 970-476-4182 Project Details: Project Number: 4797 Conducted: September 29,2011 p � c� � od � OCT 0 5 2011 -rov�ra �� �:ai� EXECUTIVE SUMMARY On September 29, 2011, Mr. Brandon Sinkbeil with DS Consulting, Inc. (DSC) performed a limited asbestos inspection and collected asbestos bulk-samples from the single-family residence located at 4596 Meadow Dr. in Vail, Colorado. The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non-friable asbestos-containing materials (ACM) within the main level kitchen,living and dining rooms of the residence to be impacted in upcoming renovation activities. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material(ACM)as a material containing more than 1%asbestos. Mr.Sinkbeil collected a total of six (6) bulk-samples within the residence. Mr. Sinkbeil collected three (3) bulk-samples of white painted drywall surfacing texture and three (3) bulk-samples of popcorn ceiling texture from the main level. The asbestos bulk-samples were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) accredited lab in Denver, Colorado (see Appendix B for laboratory report). All of the bulk- samples collected reported none-detect for asbestos. The following is a summary of the materials sampled,their locations,and their asbestos content: Material Type: Drywall with Wallpaper Material Description: White Textured and Painted Drywall Sample Locations: Main Level Ceiling and Walls Asbestos Content: None-detect for Asbestos Material Type: Popcorn Ceiling Texture Material Description: White Foamy Spray-applied Texture Sample Locations: Main Level Ceiling Asbestos Content: None-detect for Asbestos 2 PROJECT OVERVIEW I. Introduction A limited asbestos inspection and bulk-sampling for ACM was conducted at 4596 Meadow Dr. in Vail, Colorado on September 29, 2011 at the request of Mr. Lee Sedota with LMS Construction, Ltd. There will be renovations made to the main level of the home. The limited asbestos inspection and bulk-sampling was conducted to locate any asbestos-containing materials prior to these activities. The asbestos inspection and bulk-sampling was conducted by Mr. Sinkbeil with DSC. DSC is a Colorado State Certified Asbestos Consulting Firm, Registration No. 14912. Mr. Sinkbeil is a Colorado State Certified Building Inspector,Accreditation No. 13442 (see AppendixA for certificate). II. Structural Design The residence is a wood-framed,single-family condominium within a larger,multi-unit complex. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a limited number of bulk-samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk-samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC,Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1.) The distribution of the suspect material throughout the HA. 2.) The suspect material's physical characteristics and application. 3.) Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characterisrics and the application of the sampled material can be correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the EPA's ��hod for the Determination ofAsbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk-samples was performed on the"date reported,"as listed in the bulk-sample analysis reporrt. 3 IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as homogeneous areas. Suspect materials were divided into three classifications: 1.) Surfacing Material: sprayed or troweled onto structural building member. 2.) Thermal System Insulation (TS/): any type of pipe, boiler, tank, or duct insulation. 3.) Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles,insulation,and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged"are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one- tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significandy damaged" condition has one or more of the following characteristics: • The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly distributed(one-quarter if the damage is localized). • One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. • Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response-action recommendations for asbestos-containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1%within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1%within the bulk-sample, or all bulk-samples in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1%unless it is analyzed by the point-count method to be less than 1%. V. Inspector Comments No asbestos-containing material was identified during the bulk-sampling conducted at 4596 Meadow Dr. in Vail, Colorado. Butk-samples of the drywall surfacing textures and popcorn ceiling texture were collected. All of the bulk-samples collected reported as none-detect for asbestos. VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent-asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at 4596 4 ' • . Meadow Dr.in Vail, Colorado,on September 29, 2011. The quantities are approximations and are subject to field verification. ND=None-detect; CHRY=Chrysotile; TR=Trace (<1%Visual Estimate). *The quantities of materials listed in this report are general approximations.On-site verification of the exact quantity of material is required. � � � . . � . . � � � � • • � . • 1 Sample#: DW-01 Sample#: DW-02 Sample Description: Drywall&Surfacing Texture Sample Description: Dtywall&Surfacing Texture Sample Location: Living Room Wall Sample Location: Kitchen Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Estimated Material Quantity: 600 ftz Estimated Material Quantity: 600 ft2 Material Condition: Good Material Condition: Good Material Friability: Friable Material Friability: Friable Layers-Asbestos Content: Layers-Asbestos Content: White tape-ND White tape- ND White joint compound- ND White joint compound- ND White texture w/white paint-ND White texture w/white paint-ND Tan white d all-ND Tan white d all-ND Recommendations: GENERAL-See Section VII Recommendations: GENERAL-See Section VII � � � • • � . 1 � � • . . � . � Sample#: DW-03 Sample #: PC-01 Sample Description: Drywall&Surfacing Texture Sample Description: Popcorn Ceiling Texture Sample Gocation: Dining Room Wall Sample Location: Dining Room Ceiling Material Classification: Surfacing Material Material Classification: Surfacing Material Estimated Material Quantity: 600 ftz Estimated Material Quantity: 400 ft2 Material Condition: Good Material Condition: Good Material Fria6ility: Friable Material Friability: Friable Layers-Asbestos Content: Layers-Asbestos Content: White tape-ND White foamy texture w/white paint-ND White joint compound- ND White texture w/white paint- ND Tan white d all- ND Recommendations: GENERAL-See Section VII Recommendations: GENERAL-See Section VII 5 ' . , � � � - - � � . � � � • . . � � . � Sample#: PC-02 Sample#: PC-03 Sample Description: Popcorn Ceiling Texture Sample Description: Popcorn Ceiling Texture Sample Location: Living Room Ceiling Sample Location: Kitchen Ceiling Material Classifrcation: Surfacing Material Material Classifrcation: Surfacing Material !, Estimated Material Quantity: 400 ftz Estimated Material Quantity: 400 ftz Material Condition: Good Material Condition: Good Material Friability: Friable Material Friability: Friable Layers-Asbestos Content: Layers-Asbestos Content: White foam texture w white aint-ND White foam texture w white aint-ND Recommendations: �L-See Section VII Recommendations: ��-See Section VII VII. Recommendations GENERAL: The laboratory results of the potential ACM sampled at 4596 Meadow Dr.in Vail, Colorado,on September 29, 2011, indicate that both the drywall and popcorn ceiling textures on the main level are none-detect for asbestos. Therefore no professional abatement activities are recommended to remove or disturb the above-referenced material. DISCLAIMER AND LIMITATIONS DSC performed the activities included in this report in a manner consistent with the level of care and expertise exercised by members of the environmental consulting profession. DSC performed all activities in accordance with all applicable federal, state, and local regulations, generally accepted standards and professional practice. No warranty is either expressed or implied. DSC assumes no responsibility or liability for error in public information utilized, statements from sources other than DSC, or developments resulting from situations outside the scope of this project. This report and the details provided within outline the inspection activities on the date(s) indicated, the limited number of bulk-samples collected, and the laboratory results of those bulk-samples. The laboratory results contained in this report apply specifically to the materials in which bulk-samples were collected. The results do not include or apply to any other materials within the structure that were not sampled but may contain asbestos. Additional inspection and bulk-sampling activities would be required to determine if any other materials contain asbestos. The information contained in this report is intended as supplementary material and is NOT to be used as the scope of work for abatement activities. DSC can provide a full scope of work for abatement upon request The results of any surfacing material indicated in this report also include any associated overspray with that material,e.g.,under carpet,above suspended ceilings,etc. 6 ' - . APPENDIX A - INSPECTOR CERTIFICATION � ,, �.�., ��, /�✓ � .�, �'r�: • , .,. � , � �, � ,��{���,} � ��~^. ��!... �� �-�Or � ��'�t.' i� ��� f �4�,i�fr �����,py.��' ti �w . ,.�'�. .�J.� �3: � � .� �/, ... � �,� �3 . ?; r.:� � � �� �::. � .� + r� t � ,�Lw` �� � �[,� � Lr`� �� �� ^ '���� r, � � -r- . - ��, , . - - . -� ---s„'�^�_-�—--� >,. � •[".�� J1� _ S :�" �Y� � STATE OF COLORADO j; �� � �:;_ ��- a� r� -y � ti l T' .1 ',. ;= ASBESTOS � z - �n� ,, � y ::: '� CERTIFICATION* �� -��1` .::,f ��A �� �j.�{ �. �l �� �",., j4= C'olorado Thparnncnt of Public HealQ� f i°'�' ' F and t:ncironmcnt ��' ` jj;. ' j �` = ��= Air Pallution Control Di�ision �� � •f '�x !�-_ .>� .�� .;; 'j,� �{ This crnitie>that A�' �'r,.� ;.'�'" ���; -- "" �F- Brandon Sinkbeil �'` ►�y` �= • -'_�`�''_ ';Y :?s. �� � '1- i Certification \u: 13�2 _'' �i= - «E ��- � �� has mrt th�rcyuirctnrnts ol�?�-7-�1)7,�'.k.S.;utd Air�)uality C'on[rol > � �; •• � Cummission Rcgiilatiun No.8,Y�rt ti,and is hcrcby certilirJ hy th� , �,s �+' statc of('oluradu in thc ti,llowin�discipline: •.:. cc��t +�_ �. As>�,= '� �� Inspector/Vlana�ement 1'lanner* � }� � : ..� �� _� +� = r: �� l�sucd: 6/ir2011 ?t f''�i .,i �_. Expirrs oa: 6/3/2012 �` " �` � ,� v/�� ��•!%�"' �,,'� +i �� :�:1 -,.��_ Mwrizaa APCD Rev�ase�tatrve _� ase �� �: �clk � U�.. .= ti f=� •�lYb.rrfiykw�l.ro/ul uMr rltA iMr po+.rxil.M aJr�tirrrn�M�islo�-appre�t�.i adetng��u,rv . . - - '�'�� rrrri(�•a�ion in Ihv rRu'i/dia�yvv7fitd obove. ��` .�-,f��. •r �i�.,._ y __ . _ s`�'.���ta''�. __ .u:.'.:Y,_� —�,`u�r:�� i1�. y,i i_y�+j��' r "- L"y"`"t..�, ,, .,�� „�,��'`� _.__ ,��-�,'� �'�L.;,,T� ,,» '�' qt „ �� . ; t ,, �,�f �� � 2� . � ,,� .� � �t� ,. ��r y�� �f r.� � .i5 N:,f�� R, r r' ':�` .;.��/ ,�•• � ti4. '��r � k` ,�'�S�\' .,� s,. ,, . .r, . r� L J '�� � ;4 �S t:•. ��♦ ��� .:�� i:�� l�. ..���♦ ��. '` ���:�� :``' � :+�' l,,` � �. APPENDIX B - LABORATORY REPORT 7 AEROb10�OC�y LAbORATORY ASSOCIATES,INCORPO(iATE[� t3949 W.ColFarz Ade Suite 205 Lakewood,CO 80401 - � Certificate of Analysis www.aerob oloav3net Client Name DS Consulting ������u Date Collected: 09/29/11 Street address 5366 Flatrock Ct � Date Received: 09/30/i l Ciry,State Z[P Momison,CO 80465 Date Analyzed: 09/30/11 Attn: I3randon Sinkbeil NVLAP Iab Code 200860-0 Date Reported: 09/30/11 Client Project Name: 459G Meadow Dr.in Vail Project[D: 11011684 Job ID• Tes�Requesred: 3002,Asbestos in Bulk Samples Method: Polarized Light Microscopy/Dispersion Staining(PLlvn,Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/ll 6,July 1993. Sample[dentification Homa � �, Non-Asbestos Non-Fibrous Mahix Physical Description of Sample/Cayer geneous P���� e Asbestos Detected Asbestos Percentage Fiber Material Material �ent am e um Y/N g Percenta e Com ition 11011684-1A White Tape N 5% ND 95 5 11011684-1B White Joint Compound N 5% ND 100 C DWO1 11011684-1C White Texture w/White Paint N 10% ND 100 C 11011684-1D Tan/White Drywall N 80% ND 10 90 G 11011684-2A White Tape N 5% ND 95 5 11011684-2B White Joint Compound N 10% ND 100 C DW02 11011684-2C White Texture w/White Paint N 10% ND 100 C 11011684-2D Tan/White Drywall N 75% ND 10 90 G 11011684-3A White Tape N 5% ND 95 5 DW03 11011684-3B White Joint Compound N 5% ND 100 C Page t ot 3 A=Amosite AC=Actinolite � �/ // /� �_ AN=Anthophyllite t,�..SL_..��' �zc�--���/�+-�;f`�' CHRY�;hrysotile CR=Crocidolite TR=Tremolite ic ar egrzyn a ppe Trac�L.ess Than 1% Laboratory Analyst Asbestos Laboratory Supervisor NI�None Detected 13949 W.Colfax Ave.Suite 205,Lakewood CO 80401,303.232.3746 Q=Q�attz P=Perlite C=Carbonates B=Binder G=Gypsum I�Diatoms M=Mica T=Taz NTR=Non-Asbestifocm TR NAC=Non-Asbestiform AC AEROb10�OC�y LAbORATORy ASSOCIATES, INCORPORATEO 13949 W.Colfax ASe Suite 205 Lakewood,CO 80401 � Certificate of Analysis www.aeroti oloav.net Client Natne DS Consulting ������a Date Collected: 09/29/11 Street address 5366 Flatrock Ct � Date Received: 09/30/I 1 City,State ZIP Morrison,CO 80465 Date Malyzed: 09/30/i l Attn: I3randon Sinkbeil NvI.AP Cab Code 200860-0 Date Reported: 09/30/11 Client Project Name: 459G Ncadow Dr.in Vail Project ID: 11011684 Job ID: Test Requesced: 3002,Asbestos in Bulk Ssmples Method: Polarized Light Microscopy/Dispersion Staining(PLIv�,Method fa the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993. Sample Identification HO"1° �y� Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/L.ayer geneous Asbestos Detected Asbestos Percentage Fiber Material Material C ient am e um r Y Percentage Percenta e Com ition 11011684-3C White Texture w/White Paint N 5% ND 100 C DW03 1 1 01 1 684-3D Tan/White Drywall N 85% ND 10 90 G DCOI 11011684-4 White Foamy Texture w/White Paint N 100% ND 100 C PCO2 11011684-5 White Foamy Texture w/White Paint N 100% ND ]00 C PC03 11011684-6 White Foamy Texture w/White Paint N 100% ND 100 C Page 2 of 3 A=Amosite AC=Actinolite v AN=Anthophyllite ��_��- �I<<_.� �/�'-�j'/`'k` CHRY�hrysotile CR=Crocidolite TR=Tremolite c egrzyn a ppe Trac�Less Than I% Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected 13949 W.Colfax Ave.Suite 205,Lakewood CO 80401,303.232.3746 Q=Quattz P=Perlite C=Carbonates B=Binder G=Crypsum D=Diatoms M=Mica T=Tar NTR=Non-Asbestifortn TR NAC=Non-Asbestiform AC AEROb10�OC�y LAbORATORy ASSOCIATES, INCORPORATE� -��� � Certiiicate of Analysis 13949 W.Colfa�c Ave Suite 205 Lakewood,CO 80401 303.232.3746 www.aerobioloqy.net DS Consulting 5366 Flatrock Ct Morrison,CO 80465 Brandon Sinkbeil Client Project Name 4596 Meadow Dr. in Vail a�da�o NVLAP Lab Code 200860-0 Date Coliected: 09/29/I 1 Date Received: 09/30/11 Date Analyzed: 09/30/11 Date Reported: 09/30/11 Project ID: 11011684 Job ID: General Notes ND indicates no asbestos was detected;the method detection limit is 1 %. Trace or"<1"indicates asbestos was identified in the sample,but the concentration is less than 1%. ♦ All regulated asbestos minerals(i.e.chrysotile,amosite,crocidolite,anthophyllite,tremolite,and actinolite)were sought in every layer of each sample,but only those asbestos minerals detected are listed.Amosite is the common name for the asbesriform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiforrn variety of the mineral riebeckite. ♦ Tile,vinyl,foam,plastic,and fine powder samples may contain asbestos fibers of such small diameter(<0.25 microns in diameter)that these fibers cannot be detected by PLM. For such samples,more sensitive analytical methods(e.g.T'EM,SEM,and XRD)are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regularions. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates,Inc.'s cunent terms and conditions of sale,including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report,Aerobiology Laboratory Associates,Inc.will store the samples for a minimum period of thirty(30)days before discarding. A shipping and handling charge will be assessed for the retum of any samples. ♦ Aerobiology does not guarantee the results of tape lifts,microvacs,wipe,and/or debris samples. Accurate analysis cannot be performed due to particle size,media used,and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result ojND does not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the speciftc sample for the reasons listed above. Notes Reauired bv NVLAP ♦ This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST,or any agency of the Federal Government. ♦ This test report relates only to the items tested or calibrated. • This report is not valid unless it bears the name of a NVLAP-approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. Page 3 of 3 13949 W.Colfax Ave.Suite 205,Lakewood CO 80401,303.232.3746 Wire Nut Electric Inc PO Box 1112 Avon,CO 81620 (970)926-8855 Fax (970)926-8854 Load Calculation Attention: Lee Sudoto The following is the load calculation for the residence at 9�96 Meadow DR SunWood Unit B1 General Load 1000ft2@3VA 3, OOOVA Three 20 Appliance circuits 1500 VA@ 4, 500 VA Laundry circuit 1, 500 VA Range 9, 200 VA Water heater 4, 500 VA Dryer 5, 000 VA Dishwasher 1, 200 VA Steamer 6, 000 VA Total 34, 900 VA First 10KVA @100% 10, 000 VA 25, 900 @ 40% 9, 960 VA Total Adjusted General Load 19, 960VA Total Heat Load 10, 000 VA First 10KVA @ 100% 10, 000 VA Total Adjusted Heating Load 10, 000 VA Total Adjusted General Load 19, 960 VA Total 29,960 VA 29,960 VA = 240 V = 124.8 Amps Service to unit is 125 Amps Thank you. Please call with any questions