HomeMy WebLinkAboutB11-0414 NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
. .y
�c��oeu�; .
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B11-0414
Project #: PRJ11-0607
Job Address: 4507 MEADOW DR VAIL Applied.....: 10/07/2011
Location......: SUNWOOD CONDOS UNIT B1 Issued. . . : 10/07/2011
Parcel No....: 210112425007
OWNER KING,STEVEN C. &MELISSA H. 10/07/2011
5406 BROOKSIDE CT
DOYLESTOWN
PA 18902
CONTRACTOR LMS CONSTRUCTION 10/07/2011 Phone: 970-393-2163
PO BOX 3497
VAIL
CO 81658
License: C000003348
APPLICANT LMS TILE&CONSTRUCTION 10/07/2011 Phone:970-845-5030
PO BOX 3497
VAIL
CO 81658
License: 1013-B
Description:
KITCHEN AND BATHROOM(TWO)REMODEL.NEW DOORS,BASE AND
CASE,NEW TILE FLOOR, NEW WOOD FLOOR.REPLACE BATH FIXTURES
AND VALVES.
Occupancy: Type Construction: Valuation: $24,000.00
.............................,,...,...,,.,.................,......,................« FEE SUMMARY .......,....,,�....,.........,..,.............,,....,..................,..........
Building Permit-----------> $377.25 Bldg Plan Check----------> $245.21 Use Tax Fee-----------------------> $280.00
Electrical Permit---------> $115.00 Elec Plan Check-----------> $74.75 Restuarant Plan Review--------> $0.00
Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $0.00
Plumbing Permit--------> $30.00 Plmb Plan Check---------> $7.50 Recreation Fee--------------------> $0.00
Investigation-----------------------> $608.50
Will Call------------------------------> $15.00
TOTAL PERMIT FEES-------------> $1,984.46
Payments------------------------------> $1,984.46
BALANCE DUE-----------------------> $0.00
............................>.....,........,,.«....._........,....,.............,..,..,............................,,..,.,,.,,.......................,�.......,........».,.........,.....
DECLARATIONS
I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the information
as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE Y TE EPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM-4:00 M.
Signatu e of Owner or C�or Da e
�.-P� S-��f a�--�
Print Name
combination permit_012811
t
......' �� , �
������ �
....w.....ee:..ew......x,r......x.e....x..w..+.x.x�.++xxx:�x�.�xxxxxxx.x..x........�....re,r......a....e.+.+.x.+xx..x.xxx.+wx.x....w.......e.xxxxxxxw�r.+x.•......e.....xx...xw.........
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit#: 611-0414 Address: 4507 MEADOW DR VAIL
Owner: KING, STEVEN C. & MELISSA H. Location:
SUNWOOD CONDOS UNIT 61
...........................................>...,,..,......».,.,.......,...�...,,,...x.,,..,..,...,........,......,.,,,.......,.«.........,,.........,.,......,,....,................,
combination permit_012811
f
�
�I����� i
,r***tr*t*t**�****r*tr*t**r,t*,t***r***********,t,t****�***trt+r*trter,r*,t****+*+r****trtrttr t*,t*,rtnt*****www****+*tttr***tr**,ttr*,t*w,t,t*tttrtrr**xr,rw,t*+t*ve*+rr**rr,t**,r,rwx,t
REQUIRED INSPECTIONS AND STATUSES
Permit#: B11-0414 Address: 4507 MEADOW DR VAIL
Owner: KING, STEVEN C. & MELISSA H. Location:
SUNWOOD CONDOS UNIT B1
�.******,,,,**,�**„�**�,.************««*«******«*«.*********.*.*********.,**,,*..***************,*************„«„**«*************«***********«**«*«�*****«*
Item: 00120 ELEC-Rough
Item: 00220 PLMB-Rough/D.W.V.
Item: 00230 PLMB-Rough/Water
Item: 00030 BLDG-Framing
Item: 00050 BLDG-Insulation
Item: 00060 BLDG-Sheetrock Nail
Item: 00290 PLMB-Final
Item: 00190 ELEC-Final
Item: 00090 BLDG-Final
combination permit_012811
**********************�*****************************************************++***********+**
TOWN OF VAIL, COLORADO Statement
**********+*******++********�*****++****************************�*****++++********+++*******
Statement Number: R110001426 Amount: $1, 739.25 10/07/201101:59 PM
Payment Method: Check Init: SAB
Notation: 0173 - LMS
CONSTRUCTION
-----------------------------------------------------------------------------
Permit No: B11-0414 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-124-2500-7
Site Address: 4507 MEADOW DR VAIL
Location: SUNWOOD CONDOS UNIT B1
Total Fees: $1, 984 .46
This Payment: $1, 739.25 Total ALL Pmts: $1, 984 .46
Balance: $0. 00
************+*******************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 377.25
EP 00100003111100 ELECTRICAL PERMIT FEES 115.00
PF 00100003112300 PLAN CHECK FEES 82 .25
PN 00100003153000 INVESTIGATION FEE (BLDG) 839.75
PP 00100003111100 PLUMBING PERMIT FEES 30. 00
UT 11000003106000 USE TAX 4� 280.00
WC 00100003112800 WILL CALL INSPECTION FEE 15.00
-----------------------------------------------------------------------------
B11-0414 : Entries for Item:90 - BLDG-Final 14:03 01/03/2014
Action Comments By Date Unique_
Ke
AP sgremmer 11/30/2011 A000147
112
Total Rows: 1
Page 1
3�
Department of Community Development
� � 75 South Frontage Road
TOWN 0� VAIL ' va�i, CO 81657
Tel: 970-479-2128
� www.vailgov.com
1�� Development Review Coordinator
�
/ '
� ����� �
BUILDlNG PERMIT APPLICATION
(Separate applications are required for alarm &sprinkler)
Project Street Address: Project#: �/�S� � - (����
�.: �l� �1-e�,c�0� D( ���
(Number) (Street) (Suite#) DRB#: '-� -
Building/Complex Name: 7U/1 WOC1� Building Permit#:_
Contractor Information��� Lot#: Block# Subdivision:
L 1�� � ��n S�-rv C �v�l ---__ _ _ __ ----- __ ___ _________.
Business Name: � ` ,
� �D� �y � � Work Class: New( ) Addition( ) Alteration(��
Business Address:
City \f�/�, � State:_��Zip:_� Type of Building: �
� Single-Family� Duplex( �Multi-Family( �
Contact Name: � " � �"����y �-�r � Commercial( ) Other( )
Contact Phone: �-]l� ` 6 � �� Z� �L�
r ! Work Type: Interior(� Exterior( ) Both ( ) i
Contact E-Mail: l�.�l�o n�-r'V(;��n/3 3']�_
G'"�`i' � CO►''"` Valuation of
X Work Included Plans Included Work
Owner/ wner's Representative Signature(Required) Electrical (�Yes ( )No ( )Yes ( )No '17 LZ--
Applicant Information Mechanical ( )Yes ( )No ( )Yes ( )No -
Applicant Name: �c }-Q�V�"�-�` Plumbing (�Yes ( )No ( )Yes ( )No �
� Building (�)Yes ( )No ( )Yes ( )No - b �� �
Applicant Phone: C(�G��i� �- Z� '"� �
Applicant E-Mail: Value of all work being performed: $
�value based on IBC Section 109.3�IRC Section 108.3�
Project Information `' Electrical Square Footage �K.
Owner Name: 1� �n q �i(;�,Q,vl,�,l,
arcel#: ��C� ` Z� d��
or P ,contact Eagle County Assessors O�ce at(970-328-8640 or visit
www.eaglecounty.uslpatie) --•
--—
�__�,_:_._.____� ._ __------._._ _...
Detailed Scope and Location of W ork: �a- ('�t C��, �1/t) (� �(/►�h(-UT1}�'� !`Q,y►')U �
�..Q;�� �(��'(` S f J�S�—�1��.�('Jn�k.�l'1,`e,�J -�-,� � ��OU�
! �:t,✓ ttioo� �loo� ,fZ.�nl c�c.� P�c,��-�-- ��Y�I-�rt� G� �/_ G�
!(use additional sheet if necessary)
i
For Office Use Only: Date Received:
Fee Paid: ���•Z � D
Received From: U'Ll S (_.'w-i�'���-t�v�-• l�f"�- �C� 0 5 2011
Cash Check # v t �
CC: Visa / MC Last 4 CC # exp date: T�WN OF VAIL
Auth #
O 1-Jan-11
�
.
��IVQ�`VA1I,''` BUILDING PERMIT SUBMITTAL REQUIREMENTS
Residential condominium remodels/additions (multifamily IBC buildinqs)
***Return this form with your application***
�ets of plans required to be submitted
`�( (� Supply DRB application number(i.e. DR6090001) or copy of DRB Action Form
�rchitect stamp required on architectural plans. Architect or Engineer's stamp is required on
structural, mechanical, plumbing and electrical plans. Remodel projects not disturbing fire resistive
construction within the building may not require stamped plans please contact TOV Building
Department staff with any questions.
❑ Building construction type, occupancy, fire sprinkler/alarm information and code analysis for existing
building shall be included on the plans.
,o/ Asbestos project checklist&testing results � ��'l.9"1^�Z�
❑ Include a key plan showing location of the unit within the building complex. Show location of all
existing or proposed exit doors, corridors or stairways from the unit or building.
ry Floor plans for the unit showing all proposed work. Clearly show new, existing and demolished walls.
Indicate wall assembly types (wood or steel studs)
�� Include a door schedule for any new doors. Include information on fire rating as required
❑ Fire rating assembly details for floor/ceiling or roof/ceiling and fire rated walls required.
❑ Fire rating details for recessed light fixtures if lighting is located in a fire rated ceiling.
t� For additions, include energy code compliance forms (COMcheck or REScheck)
�` http://www.enerqycodes.qov
❑ Structural plans for any proposed structural work. (stamped and signed by architect or engineer)
�� Mechanical plans required for all proposed mechanical work. Bath fans, dryer duct, kitchen exhaust,
�HVAC ducts and any heating or cooling equipment. Show fire dampers as required on ductwork
ptans. (stamped and signed by engineer or architect)
�� Plumbing plans for all proposed plumbing work. Include gas piping and sizing plan, drain/waste/vent
and water piping. (stamped and signed by engineer or architect)
o�Electrical plans for all proposed work. Include electrical power and lighting plans, panel schedule
and load calculations. (stamped and signed by engineer or architect)
.�_,�,..'�,'�-�_ S t^_o-�,t,s� cJ,� `";'�'�— � c;�--�
NOTES:
�
F:\CDev\BUILDING\checklists\Condominium remodel 022410.doc
� � . .
' i
i
■
_...
onsu ln
Asbestos Inspection and Sampling Report
4596 Meadow Dr. in Vail, Colorado 81657
Presented To:
Mr. Lee Sedota
LMS Construction,Ltd.
LMSconstruction337@gmail.com
Cell: 970-393-2163
Fax: 970-845-5030
Performed&Prepared By:
Mr. Brandon Sinkbeil
DS Consulting, Inc.
PO Box 6864
Avon,CO 81620
Cell: 970-476-4182
Project Details:
Project Number: 4797
Conducted: September 29,2011
p � c� � od �
OCT 0 5 2011
-rov�ra �� �:ai�
EXECUTIVE SUMMARY
On September 29, 2011, Mr. Brandon Sinkbeil with DS Consulting, Inc. (DSC) performed a limited
asbestos inspection and collected asbestos bulk-samples from the single-family residence located at 4596
Meadow Dr. in Vail, Colorado. The purpose of the inspection was to identify, sample and assess
potentially hazardous friable and non-friable asbestos-containing materials (ACM) within the main level
kitchen,living and dining rooms of the residence to be impacted in upcoming renovation activities.
The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an
asbestos-containing material(ACM)as a material containing more than 1%asbestos.
Mr.Sinkbeil collected a total of six (6) bulk-samples within the residence. Mr. Sinkbeil collected three (3)
bulk-samples of white painted drywall surfacing texture and three (3) bulk-samples of popcorn ceiling
texture from the main level.
The asbestos bulk-samples were analyzed by a National Voluntary Laboratory Accreditation Program
(NVLAP) accredited lab in Denver, Colorado (see Appendix B for laboratory report). All of the bulk-
samples collected reported none-detect for asbestos. The following is a summary of the materials
sampled,their locations,and their asbestos content:
Material Type: Drywall with Wallpaper
Material Description: White Textured and Painted Drywall
Sample Locations: Main Level Ceiling and Walls
Asbestos Content: None-detect for Asbestos
Material Type: Popcorn Ceiling Texture
Material Description: White Foamy Spray-applied Texture
Sample Locations: Main Level Ceiling
Asbestos Content: None-detect for Asbestos
2
PROJECT OVERVIEW
I. Introduction
A limited asbestos inspection and bulk-sampling for ACM was conducted at 4596 Meadow Dr. in Vail,
Colorado on September 29, 2011 at the request of Mr. Lee Sedota with LMS Construction, Ltd. There will
be renovations made to the main level of the home. The limited asbestos inspection and bulk-sampling
was conducted to locate any asbestos-containing materials prior to these activities.
The asbestos inspection and bulk-sampling was conducted by Mr. Sinkbeil with DSC. DSC is a Colorado
State Certified Asbestos Consulting Firm, Registration No. 14912. Mr. Sinkbeil is a Colorado State
Certified Building Inspector,Accreditation No. 13442 (see AppendixA for certificate).
II. Structural Design
The residence is a wood-framed,single-family condominium within a larger,multi-unit complex.
III. Sampling and Analytical Procedures
The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building
Inspector qualified by experience, education and training in the recognition of potential ACM and
approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a
limited number of bulk-samples being collected within the residence.
The inspection, assessment and sampling were performed in accordance with Environmental Protection
Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of
concern and the collection and analysis of representative bulk-samples of suspect material.
Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not
broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be
located in these and other inaccessible areas.
Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of
each homogeneous area (HA), were collected according to the guidelines published as Environmental
Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC,Sections
2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the
following criteria: 1.) The distribution of the suspect material throughout the HA. 2.) The suspect
material's physical characteristics and application. 3.) Random sampling patterns determined for each
HA.
Suspect materials sampled and analyzed should be considered to be representative of materials in each
HA if they exhibit similar physical characterisrics and the application of the sampled material can be
correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the
EPA's ��hod for the Determination ofAsbestos in Bulk Building Materials (EPA 600/R/116, July, 1993)
and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the
bulk-samples was performed on the"date reported,"as listed in the bulk-sample analysis reporrt.
3
IV. Notes on Report Format
Suspect materials alike in appearance and application were sampled as homogeneous areas. Suspect
materials were divided into three classifications: 1.) Surfacing Material: sprayed or troweled onto
structural building member. 2.) Thermal System Insulation (TS/): any type of pipe, boiler, tank, or duct
insulation. 3.) Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling
tiles,insulation,and finishing materials.
Condition assessments were performed by the accredited inspector at the time of inspection. Condition
assessments are listed in the following section. Ratings of "good," "damaged," and "significantly
damaged"are meant to indicate the overall condition of the material.
A material in "good" condition has no visible damage or deterioration, or showing only very limited
damage or deterioration. A material in "damaged" condition has the following characteristics: The
surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-
tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized).
Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces
beneath the material can be used as confirmatory evidence. A material in "significandy damaged"
condition has one or more of the following characteristics:
• The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly
distributed(one-quarter if the damage is localized).
• One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or
showing adhesive failure.
• Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris
similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence.
Response-action recommendations for asbestos-containing HAs are listed in the section VII.
Recommendations may be for more than one HA, if materials are alike. Recommendations are either
"general" or "immediate." An immediate recommendation indicates the presence of asbestos greater
than 1%within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly.
A general recommendation indicates asbestos does not exist greater than 1%within the bulk-sample, or
all bulk-samples in the same HA, and no further abatement activities are required for removal of the
material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for
asbestos greater than 1%unless it is analyzed by the point-count method to be less than 1%.
V. Inspector Comments
No asbestos-containing material was identified during the bulk-sampling conducted at 4596 Meadow Dr.
in Vail, Colorado. Butk-samples of the drywall surfacing textures and popcorn ceiling texture were
collected. All of the bulk-samples collected reported as none-detect for asbestos.
VI. Homogeneous Area Descriptions
The following section contains sampled HA descriptions and sample locations. Percent-asbestos content
for each sample indicated can vary depending on sample locations, homogeneity of the materials, and
type of application. The following samples were collected from the single family residence at 4596
4
' • .
Meadow Dr.in Vail, Colorado,on September 29, 2011. The quantities are approximations and are subject
to field verification. ND=None-detect; CHRY=Chrysotile; TR=Trace (<1%Visual Estimate).
*The quantities of materials listed in this report are general approximations.On-site verification of the exact quantity
of material is required.
� � � . . � . . � � � � • • � . • 1
Sample#: DW-01 Sample#: DW-02
Sample Description: Drywall&Surfacing Texture Sample Description: Dtywall&Surfacing Texture
Sample Location: Living Room Wall Sample Location: Kitchen Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Estimated Material Quantity: 600 ftz Estimated Material Quantity: 600 ft2
Material Condition: Good Material Condition: Good
Material Friability: Friable Material Friability: Friable
Layers-Asbestos Content: Layers-Asbestos Content:
White tape-ND White tape- ND
White joint compound- ND White joint compound- ND
White texture w/white paint-ND White texture w/white paint-ND
Tan white d all-ND Tan white d all-ND
Recommendations: GENERAL-See Section VII Recommendations: GENERAL-See Section VII
� � � • • � . 1 � � • . . � . �
Sample#: DW-03 Sample #: PC-01
Sample Description: Drywall&Surfacing Texture Sample Description: Popcorn Ceiling Texture
Sample Gocation: Dining Room Wall Sample Location: Dining Room Ceiling
Material Classification: Surfacing Material Material Classification: Surfacing Material
Estimated Material Quantity: 600 ftz Estimated Material Quantity: 400 ft2
Material Condition: Good Material Condition: Good
Material Fria6ility: Friable Material Friability: Friable
Layers-Asbestos Content: Layers-Asbestos Content:
White tape-ND White foamy texture w/white paint-ND
White joint compound- ND
White texture w/white paint- ND
Tan white d all- ND
Recommendations: GENERAL-See Section VII Recommendations: GENERAL-See Section VII
5
' . ,
� � � - - � � . � � � • . . � � . �
Sample#: PC-02 Sample#: PC-03
Sample Description: Popcorn Ceiling Texture Sample Description: Popcorn Ceiling Texture
Sample Location: Living Room Ceiling Sample Location: Kitchen Ceiling
Material Classifrcation: Surfacing Material Material Classifrcation: Surfacing Material !,
Estimated Material Quantity: 400 ftz Estimated Material Quantity: 400 ftz
Material Condition: Good Material Condition: Good
Material Friability: Friable Material Friability: Friable
Layers-Asbestos Content: Layers-Asbestos Content:
White foam texture w white aint-ND White foam texture w white aint-ND
Recommendations: �L-See Section VII Recommendations: ��-See Section VII
VII. Recommendations
GENERAL: The laboratory results of the potential ACM sampled at 4596 Meadow Dr.in Vail, Colorado,on
September 29, 2011, indicate that both the drywall and popcorn ceiling textures on the main level are
none-detect for asbestos. Therefore no professional abatement activities are recommended to remove or
disturb the above-referenced material.
DISCLAIMER AND LIMITATIONS
DSC performed the activities included in this report in a manner consistent with the level of care and
expertise exercised by members of the environmental consulting profession. DSC performed all activities
in accordance with all applicable federal, state, and local regulations, generally accepted standards and
professional practice. No warranty is either expressed or implied. DSC assumes no responsibility or
liability for error in public information utilized, statements from sources other than DSC, or
developments resulting from situations outside the scope of this project.
This report and the details provided within outline the inspection activities on the date(s) indicated, the
limited number of bulk-samples collected, and the laboratory results of those bulk-samples. The
laboratory results contained in this report apply specifically to the materials in which bulk-samples were
collected. The results do not include or apply to any other materials within the structure that were not
sampled but may contain asbestos. Additional inspection and bulk-sampling activities would be required
to determine if any other materials contain asbestos.
The information contained in this report is intended as supplementary material and is NOT to be used as
the scope of work for abatement activities. DSC can provide a full scope of work for abatement upon
request The results of any surfacing material indicated in this report also include any associated
overspray with that material,e.g.,under carpet,above suspended ceilings,etc.
6
' - .
APPENDIX A - INSPECTOR CERTIFICATION
� ,, �.�., ��, /�✓ � .�, �'r�: • , .,. � , � �, �
,��{���,} � ��~^. ��!... �� �-�Or � ��'�t.' i� ��� f �4�,i�fr �����,py.��' ti �w . ,.�'�.
.�J.� �3: � � .� �/, ... � �,� �3 . ?; r.:� � � �� �::. � .� + r� t
� ,�Lw` �� � �[,� � Lr`� �� �� ^ '����
r, � � -r- . - ��, , . - - . -� ---s„'�^�_-�—--� >,. �
•[".�� J1�
_ S
:�" �Y� � STATE OF COLORADO j; �� �
�:;_ ��- a� r�
-y �
ti
l T' .1 ',.
;= ASBESTOS � z
- �n� ,, � y
::: '� CERTIFICATION* �� -��1`
.::,f ��A �� �j.�{
�. �l
�� �",., j4= C'olorado Thparnncnt of Public HealQ� f i°'�' '
F and t:ncironmcnt ��' ` jj;.
' j �`
= ��= Air Pallution Control Di�ision �� �
•f '�x !�-_ .>� .�� .;;
'j,� �{ This crnitie>that A�'
�'r,.� ;.'�'" ���; --
"" �F- Brandon Sinkbeil �'` ►�y` �=
• -'_�`�''_ ';Y :?s.
�� � '1-
i
Certification \u: 13�2 _''
�i= -
«E ��- �
�� has mrt th�rcyuirctnrnts ol�?�-7-�1)7,�'.k.S.;utd Air�)uality C'on[rol >
� �; ••
� Cummission Rcgiilatiun No.8,Y�rt ti,and is hcrcby certilirJ hy th� , �,s
�+' statc of('oluradu in thc ti,llowin�discipline: •.:.
cc��t +�_ �. As>�,=
'� �� Inspector/Vlana�ement 1'lanner* � }� �
: ..� �� _� +� =
r: �� l�sucd: 6/ir2011 ?t f''�i
.,i �_. Expirrs oa: 6/3/2012 �` " �`
� ,� v/�� ��•!%�"' �,,'� +i ��
:�:1 -,.��_ Mwrizaa APCD Rev�ase�tatrve _�
ase
�� �:
�clk � U�.. .=
ti f=� •�lYb.rrfiykw�l.ro/ul uMr rltA iMr po+.rxil.M aJr�tirrrn�M�islo�-appre�t�.i adetng��u,rv . .
- - '�'�� rrrri(�•a�ion in Ihv rRu'i/dia�yvv7fitd obove. ��` .�-,f��.
•r �i�.,._ y __ . _ s`�'.���ta''�. __ .u:.'.:Y,_� —�,`u�r:�� i1�. y,i i_y�+j��' r
"- L"y"`"t..�, ,, .,�� „�,��'`� _.__ ,��-�,'� �'�L.;,,T� ,,»
'�' qt
„ �� . ;
t ,, �,�f �� � 2� . � ,,� .� � �t� ,. ��r
y�� �f r.� � .i5 N:,f�� R, r r' ':�` .;.��/ ,�•• � ti4. '��r � k` ,�'�S�\' .,� s,. ,, .
.r, . r� L J '�� � ;4 �S t:•.
��♦ ��� .:�� i:�� l�. ..���♦ ��. '` ���:�� :``' � :+�' l,,` � �.
APPENDIX B - LABORATORY REPORT
7
AEROb10�OC�y LAbORATORY
ASSOCIATES,INCORPO(iATE[�
t3949 W.ColFarz Ade
Suite 205
Lakewood,CO 80401
- � Certificate of Analysis www.aerob oloav3net
Client Name DS Consulting ������u Date Collected: 09/29/11
Street address 5366 Flatrock Ct � Date Received: 09/30/i l
Ciry,State Z[P Momison,CO 80465 Date Analyzed: 09/30/11
Attn: I3randon Sinkbeil NVLAP Iab Code 200860-0 Date Reported: 09/30/11
Client Project Name: 459G Meadow Dr.in Vail Project[D: 11011684
Job ID•
Tes�Requesred: 3002,Asbestos in Bulk Samples
Method: Polarized Light Microscopy/Dispersion Staining(PLlvn,Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/ll 6,July 1993.
Sample[dentification Homa � �, Non-Asbestos Non-Fibrous Mahix
Physical Description of Sample/Cayer geneous P���� e Asbestos Detected Asbestos Percentage Fiber Material Material
�ent am e um Y/N g Percenta e Com ition
11011684-1A White Tape N 5% ND 95 5
11011684-1B White Joint Compound N 5% ND 100 C
DWO1
11011684-1C White Texture w/White Paint N 10% ND 100 C
11011684-1D Tan/White Drywall N 80% ND 10 90 G
11011684-2A White Tape N 5% ND 95 5
11011684-2B White Joint Compound N 10% ND 100 C
DW02
11011684-2C White Texture w/White Paint N 10% ND 100 C
11011684-2D Tan/White Drywall N 75% ND 10 90 G
11011684-3A White Tape N 5% ND 95 5
DW03
11011684-3B White Joint Compound N 5% ND 100 C
Page t ot 3
A=Amosite
AC=Actinolite
� �/ // /� �_ AN=Anthophyllite
t,�..SL_..��' �zc�--���/�+-�;f`�' CHRY�;hrysotile
CR=Crocidolite
TR=Tremolite
ic ar egrzyn a ppe Trac�L.ess Than 1%
Laboratory Analyst Asbestos Laboratory Supervisor NI�None Detected
13949 W.Colfax Ave.Suite 205,Lakewood CO 80401,303.232.3746
Q=Q�attz P=Perlite
C=Carbonates B=Binder
G=Gypsum I�Diatoms
M=Mica
T=Taz
NTR=Non-Asbestifocm TR
NAC=Non-Asbestiform AC
AEROb10�OC�y LAbORATORy
ASSOCIATES, INCORPORATEO
13949 W.Colfax ASe
Suite 205
Lakewood,CO 80401
� Certificate of Analysis
www.aeroti oloav.net
Client Natne DS Consulting ������a Date Collected: 09/29/11
Street address 5366 Flatrock Ct � Date Received: 09/30/I 1
City,State ZIP Morrison,CO 80465 Date Malyzed: 09/30/i l
Attn: I3randon Sinkbeil NvI.AP Cab Code 200860-0 Date Reported: 09/30/11
Client Project Name: 459G Ncadow Dr.in Vail Project ID: 11011684
Job ID:
Test Requesced: 3002,Asbestos in Bulk Ssmples
Method: Polarized Light Microscopy/Dispersion Staining(PLIv�,Method fa the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993.
Sample Identification HO"1° �y� Non-Asbestos Non-Fibrous Matrix
Physical Description of Sample/L.ayer geneous Asbestos Detected Asbestos Percentage Fiber Material Material
C ient am e um r Y Percentage Percenta e Com ition
11011684-3C White Texture w/White Paint N 5% ND 100 C
DW03
1 1 01 1 684-3D Tan/White Drywall N 85% ND 10 90 G
DCOI 11011684-4 White Foamy Texture w/White Paint N 100% ND 100 C
PCO2 11011684-5 White Foamy Texture w/White Paint N 100% ND ]00 C
PC03 11011684-6 White Foamy Texture w/White Paint N 100% ND 100 C
Page 2 of 3
A=Amosite
AC=Actinolite
v AN=Anthophyllite
��_��- �I<<_.� �/�'-�j'/`'k` CHRY�hrysotile
CR=Crocidolite
TR=Tremolite
c egrzyn a ppe Trac�Less Than I%
Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected
13949 W.Colfax Ave.Suite 205,Lakewood CO 80401,303.232.3746
Q=Quattz P=Perlite
C=Carbonates B=Binder
G=Crypsum D=Diatoms
M=Mica
T=Tar
NTR=Non-Asbestifortn TR
NAC=Non-Asbestiform AC
AEROb10�OC�y LAbORATORy
ASSOCIATES, INCORPORATE�
-��� �
Certiiicate of Analysis
13949 W.Colfa�c Ave
Suite 205
Lakewood,CO 80401
303.232.3746
www.aerobioloqy.net
DS Consulting
5366 Flatrock Ct
Morrison,CO 80465
Brandon Sinkbeil
Client Project Name
4596 Meadow Dr. in Vail
a�da�o
NVLAP Lab Code 200860-0
Date Coliected: 09/29/I 1
Date Received: 09/30/11
Date Analyzed: 09/30/11
Date Reported: 09/30/11
Project ID: 11011684
Job ID:
General Notes
ND indicates no asbestos was detected;the method detection limit is 1 %.
Trace or"<1"indicates asbestos was identified in the sample,but the concentration is less than 1%.
♦ All regulated asbestos minerals(i.e.chrysotile,amosite,crocidolite,anthophyllite,tremolite,and actinolite)were sought in every layer of each sample,but only those asbestos
minerals detected are listed.Amosite is the common name for the asbesriform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the
asbestiforrn variety of the mineral riebeckite.
♦ Tile,vinyl,foam,plastic,and fine powder samples may contain asbestos fibers of such small diameter(<0.25 microns in diameter)that these fibers cannot be detected by PLM.
For such samples,more sensitive analytical methods(e.g.T'EM,SEM,and XRD)are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM
floor tile analysis is accepted under NESHAP regularions.
♦ These results are submitted pursuant to Aerobiology Laboratory Associates,Inc.'s cunent terms and conditions of sale,including the company's standard warranty and limitation
of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.
♦ Unless notified in writing to return the samples covered by this report,Aerobiology Laboratory Associates,Inc.will store the samples for a minimum period of thirty(30)days
before discarding. A shipping and handling charge will be assessed for the retum of any samples.
♦ Aerobiology does not guarantee the results of tape lifts,microvacs,wipe,and/or debris samples. Accurate analysis cannot be performed due to particle size,media used,and/or
amount of material given. Analysis of these materials should be preformed by a TEM. A result ojND does not indicate that the sample area does not contain asbestos. It means the
analyst could not identify asbestos in the speciftc sample for the reasons listed above.
Notes Reauired bv NVLAP
♦ This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST,or any agency of the Federal Government.
♦ This test report relates only to the items tested or calibrated.
• This report is not valid unless it bears the name of a NVLAP-approved signatory.
♦ Any reproduction of this document must include the entire document in order for the report to be valid.
Page 3 of 3
13949 W.Colfax Ave.Suite 205,Lakewood CO 80401,303.232.3746
Wire Nut Electric Inc
PO Box 1112
Avon,CO 81620
(970)926-8855
Fax (970)926-8854
Load Calculation
Attention:
Lee Sudoto
The following is the load calculation for
the residence at
9�96 Meadow DR
SunWood Unit B1
General Load
1000ft2@3VA 3, OOOVA
Three 20 Appliance circuits 1500 VA@ 4, 500 VA
Laundry circuit 1, 500 VA
Range 9, 200 VA
Water heater 4, 500 VA
Dryer 5, 000 VA
Dishwasher 1, 200 VA
Steamer 6, 000 VA
Total 34, 900 VA
First 10KVA @100% 10, 000 VA
25, 900 @ 40% 9, 960 VA
Total Adjusted General Load 19, 960VA
Total Heat Load 10, 000 VA
First 10KVA @ 100% 10, 000 VA
Total Adjusted Heating Load 10, 000 VA
Total Adjusted General Load 19, 960 VA
Total 29,960 VA
29,960 VA = 240 V = 124.8 Amps
Service to unit is 125 Amps
Thank you. Please call with any questions