Loading...
HomeMy WebLinkAboutTemp00320 F--- � ENTRY DOOR STONE WALL ASSEMBLY SOIL BACKFILL CONCREfE WALL - SEE w - � = I SEE DOOR SCHEDULE 8" CMU HEADER HOT RUBBERIZED ASPHALT WATERPROOFING STRUCTURAL DRAWINGS , � , ti � � � � � � � STRUCTURAL SLAB, S.S.D. 3/8" EXPANSION SHELL � SEE PLANS � EACH "Z° BRACKET - = I 1» GAP FLOOR FINISH. � ����������\� �\��\ ` �\ ` �\ ` . . � . �� . \� . �� . � i-- � CLEAR L SIDES ADJUST THICKNESS FOR ������������ � �� ��� ��� �� �/ � �/� ��� ��� /�� o USE OVER CLOSER. L��1i��1J��l,l�� � _�\�1���1.r\�j����� r��1_\�1�\���\�_/�\,1�� EL. _ + SWNEL CARRIER . . � SHIM AS REQUIRED �. � � - . . E- I FLOOR FINISH, S.I.D., S. L.D . � p . . . - . o _ . . . . - � � - . a . : . . SEE PLAN ; �z i � � � � � . � D . . p . p , . . p � � . � p o TOP OF SLAB ALUMINUM TRACK a . . . . ° . �a a . . FOR PARTITION �` SOUND ATfENUATION , � i i � i i i � � � � � � D . . - D - . �� o . p . � . . CONT CAULKING AND BACKER = . D . . � BATT INSULATION, WHERE OCCURS I z i i i i i i � �o � . ° . . � � . � . ° . - � . - ' . ROD, BOTH SIDES c�3 . � a � . � - d : . CONCRETE WALL CMU WALL- �•` ,... ° . . . . � � `' � . - . � ° SEE STRUCTURA DRAWINGS : "- HILL GLAZIER � � - - — I i I I I I . D ; • �p � p . D . p , � � � , • . . . i � . Q � , � - - � - - -� - F.F.E. _ +100'-1 2° � . D . . o . � . - . � . . 1 MI �, � - a . . _ � . . � __-I w . \�,� ��\',, \�� `� `I `1��,\ �. .� � �� ��� �\� .��'\:`\` \�'�\\` �`:`�� \� �\� - - � � � � , . , � . ' . � D ' . , ' . . - . � . ' . .. � � . . � . . ' . , � , • � . . � � +� . � . . . '� DQUBLE STUD � JAMB _ Q ~— 16 GA HOLLOW MEfAL FRAME d A R C H I T E C T S � � �`� . �;�. �`� .� �.�.\. ,�.`��. �;;�.\, � �.`�\� ,��, LEVEL� D ° � . � SEE SCHEDULE � � � ° ° �V2" � �.\���� � \� � ° 4 . � S �� . z ��'? .>.� �� OR HEAD ezs ALNA STREET PALO ALTO CA 94301 . , . .. v ` . . . ` . . - ..�. � � . ; �. ; � � ( � - OOR STOP, BEYOND �► a C 7 . . � 1/2� � ;�� .,`� r � .t TEL 650 . 617 . 0366 FAX 650 . 617 . 0373 � : ., . _ �. . i . . _ PER MFR . � h � �n — d- � . a � � •:• = �._. ... � , �,� ` :: � '- " . . � .>. . . M � � . a - . .0 - . — 3/8 EXPANSION SNELL � EACH BRACKET a ,_,_, _ � "' � " • T. O.SLAB ` '`�'. /.,' . . ° - - - - - - - - - - - - - , . ULILILJ � � � . a . � - - --�- 16 GA MEfAL FRAME . PER PLAN _ / .. � _ _ , DOOR a � ° . � � � � � STUD ANCHOR I-=-- ♦ • I „ —' t ,. D / � ^ ^ � � � i � ,_ — — — — � n � WITH INSULATION � � , 1 � -1 -; ' �� `, �. ' ,• •� , � . � I I Z BRACKEi' 16 GA METAL FRAME � . � O . . . � . . . . . . . . . . . . . � . . � . . . o . ��;%, i ` � • � > ; , `, ; � . . _ . a T' ( SMOKE AND FIRE GASKET, WHERE OCCURS _ _ . . . FLOOR CLOSER ;;� � ; �; _ : �-`� i i } i i W � . 4 �o DOOR - SEE SCHEDULE pE CO � WHERE OCCURS Q' � ; . - . .. e � , . � ;,� �. :: e � � \ ` � � a . � � ' L PUNCH AND DRAW FOR 3 Sn FLAT HEAD '� � COVER PAN � � _ � � � a. �' ,` � C �- � � � D � � D . ° Q . D � . . . p . .� . � ` � � � °- � � _ �O SMOKE AND FlRE GASKEf �, N , y 4 O , , ' � � � �' Z BRACKET 1 i ° . � � � � I �� . . - D FLOOR CLOSER � ..> . . �>: � `• / � a 5/8 � p MEfA� SCREW � 24 OC MAX 4 MIN � O �l .: ti. o . � � . p . p . CEMENT CASE o ° . � '� ° ; � ' � - - - - ' ' � i � . � � � a � � �-V2� DOOR STOP, BEYOND DOOR STOP, BEYOND ' � ' ? . n � . � _ _ _ — _ _ _ — � c� . - � . . � o� . S1RUCTURAL SLAB, S.S.D. r- .. SMOKE RE AND Fl GASKEf �? � � �� �. cn ° � � ` b .� , - - - -- - - DOOR JAMB, BEfOND - SEE SCHEDULE �,� ; o . _ . . � � � � . . �� . < a. � - DOOR - SEE SCHEDULE �,. �� : . n . e . I � LL� , � . D . Q � D . . O . ..e e . < .. � . i o � DOOR — SEE SCHEDULE � � a � ���� ����� ° � . � Q � OVERHEAD COILING DOOR °- PUNCH & DRAW FOR 3/8" FLAT HEAD a � � o Q � PRECAST LINTEL � z � � MEfAL SCREW � 24° OC MAX - 4 MIN w cn � ~ � STONE PILASTER (BEYOND) � � � ° EXP. DATE 07/31/07 i o � w t-- ¢ ENTRY DOOR FLOOR CLOSURE " ' " OVERHEAD COILING DODR @ GARAGE SCALE: 1 °� _ , � - o" SCALE: 1 - 1 /2°�= , �- o�� � _ �_ M „ , » � S�A�E: 3 - , - o L O U V E R E D B I F O L D D O O R H E A D S C A L E: 3 1 0 _ „ � � S E C T I D N $3—s—t h r e s h ��o s e�- , o s � E N L A R G E D S E C T I O N A T H E A D s3—s-head—coil-058 � � J A M B �E T A��. 1 H E A��J a M B �E"�'a�l S C A L E: 3 - 1 - 0 S C A L E: 3 = � '- o" � S E C T I O N .D E T A I L S\D O O R\D-H E A D 1 0 � O C��I N��E T E W A L L .DETAILS DOORS D-JAM8I .DW ■ � 1 H E A D I�A M B D E T A I L � � C� WALL .DETAILS\DOORS\D-HEAD3A ■ O QY�s� �Q�p A� �T� sT�A PAR�TION ,DETAILS DOORS D-HEAD3 � w \ \ ; m � � NOTE: I � SEE ID DRAWINGS FOR TRIM � . Q � SEE PLANS SEE S i Q � FQR PARTITION SOUND ATTENUATION ; � DOOR FRAME PER MFR �� � WALL ASSEMBLY PER WALL � BATf INSULATION, WHERE OCCURS SEE PLAN � w i TYPES . . � -- :=�: FOR PARTITION � �� .. a CONCRETE WALL ::, �_: �aa . : - ���; DOUBLE STUD � JAMB i ¢ I : DBL. 20 GA. STL STUDS C� 4 � . , i, � ; :_.,. I �� GAP CLEAR ARQUND ` . . a . � � . SEE STRUCTURAL DRAWINGS Z '�_, OR HEAD �=�� �:�` :��r :: SOUND ATTENUATION BATT "'- �'� INSULATION, WHERE OCCURS f � ROUGH OPENINGS TYP. 4 . � V2° � �:� � � �� w. - = COVER PAN 4 � ., , ' " .g � .]y ',f .�'.� ., � o . � . ' � ° 3 f 8" EXPANSION SHELL � � �� ��'" r .<< :T'� z I DOOR ABOVE a . . a . a � � EACH BRACKEf ,, .: : :-;. DOUBLE STUD � JAMB � �� STUD ANCHOR '�� .�° '� � ' OR HEAD /�� � � � � � �:; ;`: :,� ,;;:. 1�/� .iA. :� . � . . ' '• . Y 4� • . . . . . '�... . �� SEE DOOR SCHEDULE V2° i 6 GA MEfAL FRAME � Q .f -.. � v ' — ------- a� C � ' ::,_ ' � � - - - --- � : ": � . � �c � � � a WITH INSULATION ,�: _4: � STUD ANCHOR '� - -1 � - WOOD MOLDING PER INTERIOR . � a � � � � ' . - �� :� �r � — � � �� � � a • � . d . � V2" 1 , r` j/� ; �� � : � �• . . � . : . . . , � � : : _ 16 GA MEfAL FRAME , � ' , . --F---- - � -----}-- -- ------- :. :. � - - - � � �o SMOKE AND FIRE GASKET, � .:; :, :' � Q _ \ � ___ _ _ � I I Z BRACKET � WHERE OCCURS � ,�y �Y^ r ' � 16 GA METAL fRAME ' w ; � � i - SMOKE AND FlRE GASKET C�D 80TH DOORS, ' DOOR STOP, BEYOND �, � �� T i EDGE OF FLOOR FINISH 3/4" WOOD JAMB � WHERE OCCURS n WITH INSULATION � PUNCH AND DRAW FOR 3/8 FLAT HEAD � \� i LINE OF CLOSER CEMENT N _ , ° I �„ MEfAL SCRE1N � 24 OC MAX 4 MIN � - - - - - _ CASE (BELOW) o DOOR AS SCHEDULED #4 BRUSHED SS DOOR - SEE SCHEDULE � EDGE OF CLOSER = DOOR - SEE SCHEDULE SMOKE AND FIRE GASK� 0 U _ D40R SEE SCHEDULE ' DOOR ST4P. BEYOND � PAN �, OR STOP, BE70ND o EDGE OF FLOOR FINISH DOOR JAMB, BEYOND - = SEE SCHEDULE BLACK GLAZING SEALANT cn 1 /4" TEMPERED GLASS PANEL - -� LINE OF CLOSER CEMENT yND-� � W� -� SEE SCHEDULE � CASE (BELOW) ' z � 0 z Q Q ENTRY D � OR FLOOR CLOSER SCALE: 3�° _ , ° — o�� HEAD/JAMB CASE OPENI S�A�E: 3„ _ , •- o» S�A�E: 3»_ , �— o» . � - , » 2 9 2 ,4, N G D E T A I L .— H E A D/J A M B D E T A I L H E A D i J A M B D S C A L E. 3 _ , — o s�A�E: 3„ — , �— o� z 19 14, ETAIL Q HEAD/JAMB DETAIL � P�.A N �E T A��. 8 3-p-t h res h-c loser-1 0 8 �CjT� .DETAILS�OP-JAMB.DWG e ��Cj'�� � ! WA�,�, ,DETAILS\DOORS\D-HEAD4A e ���,A� PA�„ �� .DETAILS DOORS D-HEAD16 V d 0 \ \ Z I'IO�� ASSE�LY .DETAIIS\DOORS\D-HEAD6.DWG ■ w _ '- NOTE: � SEE ID DRAWINGS FOR TRIM � SEE PLANS F- �" FOR PARTITION SEE PLAIVS i" SEE PLANS FOR PARTfIION SOUND ATTENUATION � _ SOUND ATfENUATION o , FOR PARTITION BATT INSULATION, WHERE OCCURS ;�: � ° BA1T INSULATION, WHERE OCCURS � �,. � � z , . ,.. ,. z ;., - .�.. . .., _• : SOUND AITENUATION � � � � � . . :i: � 1NTER/0R � � � � :: :. : i,;Y - o '• ' . .` ' '. .. . WALI PER P d d � � .. . , EXTERIOR � : : BATT INSULATION� WHERE OCCURS FOR PARTff10N TYPE MILLWORK SHOWN DASHED, � �4d . : LAN ''; '' DOUBLE STUD � JAMB ,. . . .; 4 O L`' " ' ' '" — EXTERIOR CEMENT PCASTER 0/ � '' ;� . WNERE OCCURS, S.I.D. � z . ;<< N OR HEAD � ; � � � c .' '�� a. � METAL tATH � �� °`` � a . . . ' 1 2 ,;. :' � �. O � 4 � � ..� !,. � � � z � � .•. :. ,. � .'. � � ;x; i WOOD TRIM SHOWN DASHED, - � � . CONCRETE WALL N � r- 1 2 . ;; _ : i i ..t • WATERPROOF MEMBRANE SHEET o DOUBLE STUD � JAMB `�° � � � �' i � WHERE OCCURS, S.I.D. d r � �C � 2 LAYERS OF " ' ° . . ... : . . , � - •, w 5 8" GYP. BOARD, .; i i .. ' � , ' " 2 LAYERS OF 5 8" G1P. � � � ��~ � � � � ' OR HEAD � : � �. s . . . a � ' . . _ � � .. . � A � _ �... V7' , (- V2° _ r_ ,.: 3.; DOUBLE STUD � JAMB � : � ° ° �-. , STUD ANCHOR � , � \� � TYPE- "X" . . � , •� : <:.� �: . : SNEATHING TYPE X , � � � , p �T� O a- . . i i �• • .� , , � .,• - � � FIRE-REfARDANT TREATED WOOD BLOCKING ��" v � � 1�2° 'N 16 GA METAL FRAME � ' f i v � 7/8" X 7/8" X 1 /16° METAL CHANNEI WITH INSULATION , � � . i _ � CONT. SFALANT & BACKER ROD (FIRE d " AT RATED PARTITION Q ; , ' ' ,.`� ``4'� ..—.— METAt FRAMING d- � 'y4 STUD ANCHOR � i ' � . � � - . � • - • •'.. :� :�� . ' _: .,_ . r � . ,.. .. . i i ' : • • :. V 1 � `—t ' >� � � '• •� '�' ��.; GALVANIZED SHEET METAL DRIP � 16 GA METAL FRAME � i � SEALANT � RATED CONDITION) � � a � 5/8" TYPE X GYP BD AT RATED PARTI110N = � : WITH INSULATION i WOOD JAMB/HEAD - - - - - - 16 GA METAL FRAME - SEE SCHEDULE � � ` f � : i i ' ': :', � � -, -� � \ WHERE OCCURSE GASKET, � �' Q : i i . '�� a � y '."� SMOKE AND FIRE GASKEf, WHERE OCCURS � t� ` � � N `� � z CONT SEAIANT � SMOKE AND FlRE GASKEf� � i i � � n � � ,�, � � i � �� Z ANCHOR DOOR STOP, BEYOND WHERE OCCURS i � CONCEALED CLOSER � HEAD � Q ~ �__� CONDITION, WHERE OCCURS, SEE � � � DOOR PER SCHEDUCE DOOR STOP� BEYOND DOOR SCHEDULE DOOR - SEE SCHEDULE WOOD DOOR - SEE SCNEDULE 0 Q DOOR - SEE SCHEDULE DOOR - SEE SCHEDULE DOOR JAMB, BEYOND WOOD GLAZING STOP v-, DOOR STOP, BEYOND BLACK GLAZING SEALANT c� z � � 1 /4° TEMPERED GLASS PANEL - o SEE SCHEDULE J J Q HEAD DETAIL JAMB-SIM SCALE: 3�=, �— o„ . S�A�E: 3» _ , !— o„ » . n I • 4 TYPICAL JAMB DETAIL WQOD DOOR JAMB HEAD IM. SCALE: 3 = , — o S�A�E: 3M = , � - o» � _ , � � 2 S � S ) HEAD/JAMB DETAIL SCALE: 3 _ , — o Z 3 1 � 1 HEADIJAMB DETAIL �OOR I"EAD � CE�NT PLASTER W detailJD00RS/D-HO-CPt .dwg QYPS� BOARD A�D �TAL ST�A PARTITIGN .DETAIIS\D40RS\D-HEAD3D .DETAILS\OOORS\D-HEAD78 � WALL W/F�RED PARTITION ,DETAILS\DOORS\D-HEAD3B ■ � � WOODK�.ASS PA�L DOOR .DETAILS\DOORS\D-HEAD13 � 3 SEE PLA -� SEE PLANS r- SEE PLANS FOR PARTITI�N SEE PLAN SEE PIANS SEE PLAN FOR PARTITION �:. :.. ,.. . . FOR PARTITION ..: :.,. j=; WALL PER PLAN FOR PARTITION - . . =� -__ .�. SOUND ATfENUATION BATf INSULATION, . . . .,s :°:, :>,. WHERE QCCURS ; °�`` SOUND ATTENUATION BATT � � � . ° � � �aa 7/8" FURRING CHANNEL �` ��`> I " REVEAL "J" TRIM, T1'P. H.M. FRAME '�� '�:: INSULATION, WHERE OCCURS . a � � �. �. � _ SOUND AITENUATION BATT : ,: �,:: DOUBLE STUD � JAMB � 8 � . a . . . a : 5/8 6YPSUM BOARD �'� :.' +:;` .z� : OR HEAD I �'��� °;� �.: INSULATION, WHERE OCCURS .::: �,, r'- � — DOUBLE STUD � JAMB - - � . . CONCRETE WALL - �� .�_.; -.� r.: :..� OR HEAD a � - . . SEE STRUCTURAL DRAWINGS - - DOUBLE STUD C� JAMB '° ���� ���� . • . • : ,: WINDOW PER PLAN :: ;;;:. . . d; , :` ��: : ' � s� ��� =:r � . . Q . a 3/8'° IXPANSION SHELL � - �°-� ';: OR HEAD � v2° � ;' , .�� � V�' W z z V2�`� .;� � STUD ANCHOR 1/Z" a C . � . �'1/2" EACH BRACKEf :�:- r. � � w:.: z Q � ':� �� � . •C � ° 7�8" X 7/8" X � » - ; :;� -� � `•'� .;''r �' v 4 � ��� : a . � C 1 16 MEfAL CHANNEL ' �:; �:�. < f:;� ty, :a �°.;.: :.��=_ � • : ° � � d � /8" TYPE � ��{ � � , ,.,._ - - - - - - - 5 X GYP BD � RATED PARTmON , � ,_ 1 . , . . . . :: ... � a � " 16 GA METAL FRAME - >�� �'� CONCEALED DOOR CLOSER ,: . ._ ,� ,.�--- •,� �„ ; i I ( ,, SEE SCHEDULE , I S 5 U E D F o A 3 � - � `�� � �`` -- 16 GA HOLLOW MEfAL , � I I � 16 GA METAL FRAME . y k ' '.` - -- CASED OPENING W/ INSULATION ( SMQKE AND FIRE GASKEf, WHERE OCCURS _ _ WITH JNSULATION "Z° BRACKET 04/07/06 PROGRESS CQ SET ,� . < . � � ��" REVFAt WOOD FRAME DOUB�E ACTING DOOR - SEE � PUNCH AND DRAW FOR 3/8" FLAT HEAD SMOKE AND FIRE GASKEf, WHERE OCCURS 05 12 06 SUMMARY PERMIT SE� � � MEfAL SCREW � 24 OG MAX - 4 MIN ---- -�:}°: ;. .:-:..�., :: SCHEDU�E DooR - SEE S�HE�Ul.E 05/22/07 PLAN CHECK RESUBMITTAL SHIM SFACE _ D O O R J A M B B E Y O N D - WOOD SHIM. DOOR JAMB, BEYOND p7 � g p7 CONSTRUCTION SEf �' DOOR JAMB, BEYOND ' SEE SCHEDULE � � y�� WACt PER PLAN SEE SCHEDULE DOOR - SEE SCHEDU � WOOD CASING-SJ.D. MULLION AT DOOR, DOOR STOP, BEYOND DOOR STOP, BEYOND SDUND BA ]T INSUtA7)ON WHERE OCCURS DOOR AS SCHEDULED DOOR PER PLAN, — WHERE OCCURS WOOD JAMB SCALE: 3»=, �— o„ H.M. D�OR JAINB W/ SIDELITE $CALE: 3» = , �— o„ DOOR JAMB HEAD SCALE: 3y= , �— o» ��A�E: 3H = , �— o» . y_ , „ SIM. WD.HEAD/JAMB SCALE. 3 — 1 - 0 SCALE: 3» — , �— o» � detail/doors/b-d-jb02dwg � ..\HM-JB-VNN,DWG Z Z 1 HEAD/JAMB DETAIL p 1 ETAIL HEAD/JAMB D e ACIT� � .DETAILS\DOORS\D-HEAD17 ■ � ETAIL ! WwLL W� F�A'�RHO ��HAMELS BOTH SDES .DETAILS\DOORS�D-HEAD3C ■ � Q�, �, � �� $�� ���Q DOORS D-HEAD-WD.DWG � � � CLOSER .DETAILS\DOORS\D-HEAD8 � GYPSUM BOARD AND METAL S1UD FRAMING — SEE FLOOR PLAN DOUBLE 20 GA METAL STUDS � CONCRETE WALL — SEE HEAD AND JAMB, TYP STRUCTURAL DRAWINGS • JAMB ANCHORS WELDED TO STUDS, TYP — 3�8„ EXPANSION SHELL � : � .. .•�,�: .= � � � �� ` �� �• (NOTE: PROVIDE ANCHORS � ALL EACH AZ" BRACKET SEE PLAN SEE PLAN °J" TRfM, TYP. HINGE LOCAl10NS) SEE PLAN FOR PARTITION GASKET ,.:< : : �:� .;� ELECIRO�MAGNEIIC DOOR - FOR PARTITION SHIM AS RE UIRED FOR PARTITION ' : ;::: . - Q -�' ��i SOUND ATfENUATION BATf WAlL PER PLAN HOLDER SEE SPECIFlCA110NS z;� :;. . �" REVEAL - ;�� SOUND ATfENUATION BATT � a � � , . . .A �::- =� � � � � L SOUND ATfENUATIQN BATT INSULATION, WHERE OCCURS =:° :�; �y;� INSULATION, WHERE OCCURS . - � CONT CAULKING AND BACKER ;;;` �;:� ,:: �`� �'' ���� : '. SOUND BATT INSULARON :��� ;. ; :: 7 � • � .. :, ::. :;� : �:; . - . .. �.:: ::� �:. . . . . :.. ..: ..:. : �: . � :. � : -. :.�.:_.:. =_ `` `-. — � � ROD BOTH SIDES :�: .; ,�r INSULATION, WHERE OCCURS � DOUBLE °� �� `.�' �.:� STUD � JAMB � 1 .i j =� y`; . - ti_ DOUBLE STUD � JAMB �a DOUBLE STUD � JAMB �} :y�` OR HEAD � ' � ' OR HEAD � a 16 GA HOLLOW MEfAL FRAME l : s � �z�: - • . : • . • , �� � �- - _ ;;: :;� �°�� � � . � � - - �� z .r � �: ,._:. a=� . 4 _ <r OR HEAD �� ' C J- � ; ,. ��� �-x � SEE SCHEDULE �, `'� �� °�- a :` M � z ��-, �: ;;� �: ,- V� � . . ----- - DOOR STOP ��:. :k:. STUD ANCHOR �-- i'� '��• ' � ;�= --� � ' I'1 flrl I , BEYOND ° " : sHEer TITLE � ` � �;�� � _ ~; — � n`". �„ a . ~� STUD ANCHOR " � . ULJLJLI � ,� �; � _ i ' � � �� " ' MEfAL FRAME DOOR DETAILS • � ' .� •'. � ^+< , : ' � WD. TRIM-SEE INTERIOR DWGS. .,� 4 � HEAD Q ' ` � �� - 16 GA HOLLOW MEfAL . ' . . � � - - - - - - - - JAMB 3 CASED OPENING W/ INSULATION . . . ' . �, 16 GA. METAL FRAME TRIM, SEE INTERIOR DRAWINGS � .;, . .. , , . . .. : . : � � � � ° WITH INSULATION . 4 � �" �" REVEAL SHIM SPACE DOUBLE ACTING DOOR - SEE � v. . . SMOKE AND FlRE GASKEf, SMOKE AND FlRE GASKET, WHERE OCCURS DOOR D�IENSION SEE SCHEDULE 1� SCHEDULE . a �-- 5/� Z BRACKEf D ORE-OSEERS WOOD FRAME � � � 1 �4" " " S C H E D U L E PRO � ecT o2o2s W I D T H P E R P A R T I T I O N R E C E S S E D D O O R P O C K E� D�v I E N S I O N D O O R J A M B, B E Y O N D - . . � � d o n T e o2 ts 2 DOOR PER SCHEDULE SEE SCHEDULE � ° �4 DOOR - SEE SCHEDULE T Y P E + 1 " S M O K E A N D F I R E G A S K E T / 1 0 0 7 � DOOR — SEE SCHEDULE GUEST ROOM CORRIDOR s c A � E AS NOOTED 4 ;` - ��� , : � �: � . a� � � _ � � ,. _:.� e � �- LABELED DOOR WITFI MAGNE�IC HOLD PUNCH & DRAW FOR 3/8" FLAT HEAD � 115/16° � � sHeer s �� � �' �� , � y ,� � OPEN DEVICE - SEE DOOR SCHEDULE MEfAL SCREW � 24° OC MAX - 4 MIN DOOR STOP, BEYOND � M 5 � , . ; . _ . . - M , 16 G A D O O R F R A M E - S E E S C H E D U L E . � SMOKE AND FlRE GASKET __ _ , : _ . _. , . WODD JAMB SCALE: 3�= , �— o» JAMB DETAII SCALE: 3n = , �- o� HEAD/JAM SCALE: 3�= , •—oM n n �N detail/doora/b-d-�0l .dwg � � W�A� HQ� � .DETAILS DOORS 477-DR27 � ■ � D�t�'� — 16 11 HEAD/JAMB DETAIL SCALE. 3 = , — o DOOR JAMB HEAD SIM.� SCALE: 3» — , � oy � � f DOI�LE ACTNQ DOOR .DETAILS\DOORS\D-HEAD11 QYPS� BQAR� w� �TAL ST�A I�ARTITION .DETAILS\DOORS\D-HEADt .DW � OO HILL GLA� ARCHITBG'TS� IlViG �IXI7 �STROOM ENTRY .DETAILS�QOORS D-HEAD18 � � � \ �, . .. .._ . .. .. .. . .. .. . . _ ..... . .. .... . . ._ _. . .. . _ . . . . . .. .. .. .. . . . .... . . ... . . . . . .. . . . ... ._ _ . . _. . . .. ... . ...... .... ... . _.... _._ .. .... ._... . . .... ... . _ .... .. . . _. .. .. . _... _.. . . _. ... . .... .. . . . . .._ .__ ..._. .. ._. .... ..._. .... .. ... . ._ .. _. . . ....... . .... . . ..... . . .. .. . ._ ._. . 4 . . . . . ..' .. . . . . . . _... .. . .. .. _ . . ... . ._. . .. r ... .., .... . . . . _.. . . ... . .... _ .._. ._.. .._. __. . . . .. . ... .. . .... . ... . ._. .. ... . . . ._. . . . ._ __.._ . .__ ..._ _... ... .. _.. ....... .. ._ _ . _ ._. . .. _ . . . � .