HomeMy WebLinkAboutTemp00011 _ _ _ _ _ _ __ _ . _ _ __ _ _ _ __ . _ ._ _ _ __ _ _ _ _ _ .__ _ _ _ . . _ _ . _ _ _ _ __ _ __ _ _ _ _ _ , . rc i ec ura e erence an enera � otes � = 1. THE CONTRACTOR SHALL COORDINATE THE GENERAL LAYOUT & LOCATION OF ALL �°� v PARTITIONS, DOORS, LIGHTING, TELEPHONE, DATA AND ELECTRICAL OUTLETS WITH Q THE ARCHITECTS PRIOR TO PROCEEDING WITH CONSTRUCTION. w _ ,... :..: :: �, 2. ALL PARTITIONS SHALL BE BRACED IN COMPLIANCE WITH THE REQUIREMENTS OF � ALL APPLICABLE SEISMIC AND BUILDING CODES. 0 z 3. ALL DIMENSIONS ARE TO FACE OF FINISH, U.O.N. w : :... . z 4. THE CONTRACTOR SHALL PROVIDE BLOCKING AS REQUIRED IN WALLS BEHIND ALL � � �'" �"` � �` �` � � � � A R .0 �-C,.I .T � C T S ; o MOUNTED ITEMS OF CASEWORK, ACCESSORIES, ADJUSTABLE STANDARD SHELVING, ` ` ` C� 928ALrtASTtaEEi".Pit1:.�U',fiE.TO.Cd 9A3Dt.24d3 : a �C. rEC. 630=8 t 7-Q3+�.6 'FAS 6SLY F`r t�'-037� .. � .. '.:.. : ... :. : -.-.: . .:.......:: : .: ::-: .:.......,.............- ..._...,....:...:•..;...,.. W , .... � 5. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND NOTIFY ARCHITECT OF � ANY DISCREPANCIES BEFORE PROCEEDING. w ST - z 6• ALL CLEAR CLR DIMENSIONS ARE NOT ADJUSTABLE WITHOUT THE ARCHITECT'S f-.- i � = i � � I j ° ; { i # 1 f � ) �, '. � APPROVAL � 0 � a ■ 7. PROVIDE WATER RESISTANT DRYWALL AT ALL AREAS EXPOSED TO WATER AND/OR � , ( I RECEIVING CERAMIC TILE. BPOyt011HU9I1eS ���..5.��'� I ; ,.� , i � ------ ----- ! ! ; ST - � ° 'ov� s�d Street o _ ` i I 8. VERIFY FLOOR LEVEL CHANGES. CONTRACTOR TO LEVEL FLOOR AS REQUIRED TO ��.$����'� an rancisco, CA c�n ST - � 1 � o I RECEIVE FLOOR MATERIAL. 94105 3903 � T: 415.291.8100 ° - ""---�" �-��-�"-�-��- � I � 9. DIMENSIONS LOCATING DOORS BY EDGE ARE TO THE INSIDE EDGE OF JAMB, F: 415.434.8145 DECK _,__._�.__��_______ ��_.______�---•------- � O � � � � U.O.N. www.badstudios.com � 14 � � j i � I EXHAUST FAN (PT. cn ; ID9.20 TO MATCH CLG.) �p. CONTRACTOR SHALL COORDINATE AL� WORK WITH MECHANICAL, ELECTRICAL, AND � ; '` � I PLUMBING CONTRACTORS AND REPORT JMMEDIATELY TO THE ARCHITECT ANY � � • � DISCREPANCIES FOR CORRECTION OR ADJUSTMENT. _ , a _____��____..__.__._._.w__._..�..�.....^._...._.__.__�J.__._____._-___----i- I o c� Q � � � � g�_�„ I � � � ! � � 11 . THE MILLWORK CONTRACTOR SHALL TAKE FIELD MEASUREMENTS PRIOR TO ' � PT � STARTING FABRICATION OF EACH PIECE. a i � i I � , 12. PATCH AND REPAIR EXISTING WALLS, AS REQUIRED. I ` --�-Fy � � � ---�------.__-_______.------._-i--=---.��-------r----------------�------------- ----- , , � � ! � i -8 3�4 � ( 13, PAINT FINISH ALL GYP BOARD SURFACES, U.O.N. o i � � PT _ J_\ i',-1- �- ' � I / �� � ��� � o0 14. PROVIDE BACKING FOR BASE CABINETS, WALL-HUNG CABINETS, SHE�VES, � i ( / � L A V A T O R I E S, G R A B B A R S, , i ELECTRICAL PANELS SURFACE-MOUNTED �IGHT � � --._-_-�-----._-,----i------------.�__.(.v--.---._____��_�----- ST - --�-�--- -1-�-- I F I X T U R E S A N D F O R A L L T O I L E T A C C E S S O R I E S, F I R E E X T I N G U I S H E R C A B I N E T S, � I ! � � � � � � � I WALL-MOUNTED TELEPHONE OUTLETS, WALL-MOUNTED DOOR STOPS w � � � o ��� � �� � � ¢ E � t '/ � i � ( _� crs � i � � I w ! (� � -----_-f-__�.�.�__.�_--------_�� �._---------�------- i � � - � I o ! ; � 2,^2„ I ¢ ; � w ; i � • I �, ------------- • � � � o I � - --�_._.�_._._.__.�_.__--- -_ _._._.__-_._.._.r�._____ I o c..� ; W I ¢ j � � 3 � i I � I � � i I ID9.24 � a ' --- - ---;---- --�----------- �-- � j � ----- � i �____ : � i ' � i � ef lected Ceilin Plan Generai Notes o , , / i � ; � , ; � � � o � ; _ c.n � � 1. ARCHITECTURAL REFLECTED CEILING PLANS SHOW GENERAL TYPE & SPECIFIC � z LOCATION OF LIGHT FIXTURES. � 0 z 2. EXIT SIGNS TO COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE BUILDING Q CODES. __., � 14 3. ALL LIGHT SWITCHING TO COMPLY WITH THE REQUIREMENTS OF AL� APPLICABLE � ID9.65 BUILDING CODES. � 0 W 4. THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL TRADES INVOLVED TO � INSURE CLERANCES FOR FIXTURES, DUCTS, CEfLINGS, ETC. NECESSARY TO W MAINTAIN THE SPECIFIED FINISH CEILING HEIGHT ABOVE THE FINISH FLOOR SLAB � AS NOTED ON THE DRAWINGS. CLARIFY ALL CONFLICTS WITH THE ARCHITECT. � � � cn z 5. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND � LOCATION OF ALL PLUMBING, MECHANICAL DUCTS AND ANY AND ALL OTHER � � PRESENT APPLICABLE APPURTENANCES. O z O � � 6. REFER ARCHITECTURAL ELEVATIONS DRAWINGS FOR SPECIFIC LOCATIONS OF � � = SWITCHES AND THERMOSTATS. � j�� O . � c.� z � 7. ELECTRICAL, MECHANICAL, PLUMBING, LIFE SAFETY AND FIRE SPRINKLER '„*,�� w Q CONTRACTORS MUST COORDINATE INSTALLATION AND REQUIRED CLEARANCES OF Tn V � THEIR EQUIPMENT. V 1 J ENLARGED BATHROOM '' = '•-o� ENLARGED BATHROOM '" = ''-o� p�i � FINI HE PLAN - � REFLECTED CEILING PLAN BASE-07 � , Q S S BASE 07 !�-1 �j � �r � W o � � w� w � � � � z � � � � � 0 ower and Communication General Notes � J Q 1. GENERAL CONTRACTOR SHALL VERIFY EXACT FIELD CONDITIONS FOR SWITCH AND FIXTURE LOCATIONS AS WELL AS TELEPHONE AND ELECTRICAL OUTLETS. VERIFY LOCATION OF FL�OR OUTLETS, AND OTHER OUTLETS IN RELATION T0 � � � s ; � i � � � ' i ' � i i � ' STRUCTURAL AND OTHER ELEMENTS. REPORT DISCREPANCIES TO THE ARCHITECT. D 2. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. ■ I � 3. INDICATED DIMENSIONS ARE TO THE CENTERLINE OF THE OUTLET (SWITCH) OR -'- CLUSTER OF OUTLETS (SWITCHES) U.N.O. GANG COVERPLATES SHALL BE ------ ----- ----=-- ----- I I ONE-PIECE TYPE, U.N.O. � � I 4. VERIFY EQUIPMENT MOUNTING REQUIREMENTS OF ALL ELECTRICAL, TELEPHONE � � AND OTHER EQUIPMENT. O � PF 5 Q I PF 13 5. COORDINATE INSTALLATION OF TELEPHONE AND SECURITY SYSTEMS WITH I I � OWNER'S CONSULTANT. � I 6. ALL RECEPTACLES & COVER PLATES TO BE "DECORATOR" STYLE. COLOR TO BE I � � PF � 6 I SPECIFIED BY ARCHITECT. U.N.O. - ( � 7. NOTIFY THE ARCHITECT IMMEDIATELY FOR RESOLUTION OF ANY DISCREPANCIES I � BETWEEN THE ARCHITECTURAL AND ENGINEERING DRAWINGS AND/OR FIELD � BA � 3 COND{TIONS. �ssueo Fo� � I 8. ALL ELECTRICAL AND TELEPHONE INSTALLATION SHAL� BE W STRICT � � ACCORDANCE WlTH ALL BULIDING DEPARTMENT AND FIRE DEPARTMENT CODES 0��07 f O6 PROGRESS CD SET � , � ANO oROiNANCES. 05/12/06 SUMMARY PERMIT SEf � I � 9. ALL WIRING & CABLING ABOVE CEIL�NG TQ BE PLENUM RATED PER CODE. O�1�S�O7 CONSTRUCTION SET �--�--., I � " � ��' � ( ( 10. REFER T0 JD SHE`T ID1.01 FOR POWER AND COMMUNICATION INFORMATION / � � � � � - p/� / � � � `i��'` ~�' - �-I---�--LL- 4'� � L]/'� 12 I _ � \ ( i / � 4D ID 5.350 4B � \��� -�j-� �i� � � PF 10 �1��. I 4C I I I � VANITY, SEE � � �/io9.2� BA 14 I � ------------- , I J.BOX FOR SCONCE � ( �,. � 6'-0" A.F.F., TYP. ' ------------- ( , � . � PF 18 '�, �.� � � ' I I � I � I � q.'� , � BA 16 I / I a / � TYP. ROBE HOOK / � .°` � � inishes Plan General Notes , , , 1. ALL GYP BD WALLS TO BE CUSTOM PLASTER FINISH, UON. J.BOX FOR SHAVING B/� -- 2. TRANSITION OF FLOORS OCCURRING IN OPENINGS WITH DOORS TO BE LOCATED UNDER s"£�T TiT�E MIRROR � 5'-0" THE CENTER OF THE DOOR IN THE CLOSED POSITION UON. TRANSITION oF F�ooRS ENLARGED EATHRt70M A.F.F., TYP. OCCURRING IN OPENINGS WITH NO DOOR TO BE LOCATED TO ALIGN WITH THE FACE OF THE WALL. REFER TO PLAN. 3. ALL MISC. EXPOSED ELECTRICAL CONDUIT OR RACEWAY SHAL� BE PAINTED TO MATCH ' ADJACENT WALL OR CEILING FINISH, UON. 4. THE FINISH PLAN INDICATES THE TYPES OF FINISHES. FLOOR FINISHES TO CONTINUE TO TOE KICK OR BASE OF MILLWORK, REFER TO DETAILS FOR ADDITIONAL INFORMATION. QRO��cT a2028 5. SILICON SEALANT AT GLAZING TO BE CLEAR, UON. D A T E O4 f jS��UD'�J 6. ALL FINISH MATERIALS MUST MEET ALL APPLICABLE FIRE, LIFE SAFETY, AND BUILDING C DES. s c n�.e AS SHQtid4d�! 7. ALL NEW AND EXISTING FINISHES SCHEDULED TO REMAIN SHALL BE PROTECTED DURING ,�..� � � � ��,t � ��_� CONSTRUCTION. ANY DAMAGE SHALL BE REPAIRED BY CONTRACTOR INVOLVED AS ���`u� � d � HIS COST WITH NO COST TO OWNER AND/OR TENANT. sNeEr �"` `�`""m��g 8. TRANSPARENT FINISHED WOOD DOORS, ARCHITECTURAL WOODWORK, AND CABiNETRY ���� � � �����4� � SHALL BE SHOP FINISHED. ALL VENEERS TO CONFORM TO W.I.C. PREMIUM GRADE ��,��,��.�N � STANDARDS. ������a�'� � �c �,`�i�� - 9. REPAIR AND PREPARE EXISTING SURFACES SHOWN TO REMAIN AS REQUIRED FOR APPLICATION OF NEW FINISHES. ENLARGED BATHRO�M '~ - '''°� ENLARGED BATHROOM '� - '�-�� 0. FINISH SCHEDULE FOR CONDOS TO BE ISSUED WEEK OF 7/25/07. � � POWER AND COMMUNICATION PLAN BASE-07 3 REFERENCE PLAN BASE-07 � O I�LL GL�R ,4,RCHITT�C15, IlvC ZA06 _ . . . _ _ _ _ ._ . _ ._ _ .. _ . _ __ _ _. _ . _ _ _