Loading...
HomeMy WebLinkAboutB11-0442NOTE: TH/S PERM/T MUST BE POSTED ON JOBSITE AT ALL T/MES , ,. a�c� o� ��n , Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.4792139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0442 Job Address: 595 VAIL VALLEY DR VAIL Location......: MANOR VAIL LODGE UNIT 266 Parcel No....: 210108104015 OWNER DUFFIELD, MARTYN E. 10/20/2011 DUFFIELD PRINTERS 421 KIRKSTALL RD LEEDS LS4 2HA ENGLAND APPLICANT HIGH MOUNTAIN HOMES, INC PO BOX 477 EAGLE CO 81631 License: C000003362 CONTRACTOR HIGH MOUNTAIN HOMES, INC PO BOX 477 EAGLE CO 81631 License: C000003362 10/20/2011 Phone:970-376-5475 10/20/2011 Phone:970-376-5475 Description: INSTALLATION OF SIX NEW CAN LIGHTS IN UNIT. Occupancy: Type Construction: Project #: Applied.....: Issued...: Valuation PRJ11-0642 10/20/2011 10/21/2011 $1,300.00 .»..........,, .................,,,...,.,.,>.............,,.,,,......�......,,,,..,...... FEE SUMMARY .,,.,..,,.x....,,...............,,............>,,....,,..........,,..._..,..,....,�.,. Building Permit -----------> $47.90 Bldg Plan Check ----------> $31.14 Use Tax Fee-----------------------> $0.00 Electrical Permit ---------> $115.00 Elec Plan Check -----------> $74.75 Restuarant Plan Review--------> Mechanical Permit ------> $0.00 $0.00 Mech Plan Check ---------> $0.00 Additional Fees--------------------> $0.00 Plumbing Permit --------> $0.00 Plmb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $10 00 TOTAL PERMIT FEES-------------> $278.79 Payments------------------------------> $278.79 BALANCE DUE-----------------------> $0.00 .............«....,,,,_............x............,.,...,,.,,,.,,...........,.......,.......,.......,....�,.....<........,,........�,.,,..........,.....,............,...................... DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS F R INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4• M. �� Signature of Owner or Contractor Da e ! 1 'J I l/V �'�%� Print Name combination permit_012811 � � ��lir V� �izlL � ................................................................... �........,....,........................,.......,.,...,,,,.,....,,............,.....,,...,....................,.... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11-0442 Owner: DUFFIELD, MARTYN E. MANOR VAIL LODGE UNIT 266 Address: 595 VAIL VALLEY DR VAIL Location: ....................................................................>....,,..,,....,,......,....,................�.....,x.....,...,�...,......,.....,............,.....,.............. combination permit_012811 , � �T1l�I V� I��IiL , ****««******�**«*�*«***.*„****.,*«*«*«*****.,.,«***.,***�***********,.***«w,.,.****,.*,.*««***«„«*******«„«*«*«****«.,*„*«««******««*«**««***««****««*****««„*« REQUIRED INSPECTIONS AND STATUSES Permit #: 611-0442 Owner: DUFFIELD, MARTYN E. MANOR VAIL LODGE UNIT 266 Address: 595 VAIL VALLEY DR VAIL Location: ,*„***.**,,.,,.,.,*«„**************.*„*,,,,****«***«««*«**********.*****.********.***�**„**„«*«******««*««*****�«*****************.,******«****.,*„«««««***** Item: 00120 ELEC-Rough Item: 00190 ELEC-Final Item: 00090 BLDG-Final combination permit_012811 ******+*��*+**********�*********�****************************++******************+*********+ TOWN OF VAIL, COLORADO Statement *********************++****************�***************�************************************ Statement Number: R110001526 P.mount: $204.04 10/21/201109:54 AM Payment Method:Credit Crd Init: LC Notation: CREDIT CARD FROM AUSTIN P THOMAS HIGH MOUNTAIN HOMES INC ----------------------------------------------------------------------------- Permit No: B11-0442 Type: COMBINATION BLDG PERMIT Parcel No: 2101-081-0401-5 Site Address: 595 VAIL VALLEY DR VAIL Location: MANOR VAIL LODGE UNIT 266 Total Fees: $278.79 This Payment: $204.04 Total ALL Pmts: $278.79 Balance: $0.00 ****************++******************************+*�*********+********************+********** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 47.90 EP 00100003111100 ELECTRICAL PERMIT FEES 115.00 PF 00100003112300 PLAN CHECK FEES 31.14 WC 00100003112800 WILL CALL INSPECTION FEE 10.00 ----------------------------------------------------------------------------- T�WN Q� VAIL� Project Street Address: 595 Vail Valley Drive Department of Community Development 75 South Frontage Road Vail, CO 81657 • Tel : 970-479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) 266 (Number) (Street) (Suite #) Building/Complex Name: Manor Vail Lodge Unit 266 Contractor Information Business Name: High Mountain Homes, Inc. Business Address: PO Box 477 City Eagle State: C� Zip: $1631 Contact Name: Austin Thomas Contact Phone: 970-376-5475 Contact E- i • ighmountainhomes@eagleranch.com X Owner/O er's Representative Signature (Required) Applicant Information Applicant Name: Austin Thomas Applicant Phone: 970-376-5475 Project #: pQS t l - I DRB #: �-��~ Building Permit #: �' `" � �'�,� a VI�i� Lot #:�Block # � Subdivision: _ FILt � 'i Work Class: New ( ) Addition ( ) Alteration ( ✓ ) Type of Building: Single-Family ( ) Duplex ( ) Multi-Family ( ✓ ) Commercial ( ) Other ( ) Work Type: Interior (✓) Exterior () Both () Valuation of Work Included Plans Included Work ............................................................................................... . .................. Electrical ( ✓ )Yes ( )No ( ✓ )Yes ( )No $00 Mechanical ( )Yes ( ✓ )No ( )Yes ( )No Plumbing ( )Yes ( ✓ )No ( )Yes ( )No Building ( ✓ )Yes ( )No ( ✓ )Yes ( )No 500 Applicant E-Mail: highmountainhomes@eagleranch.com Value of all work being performed: � 1300 (value based on IBC Section 109.3 & IRC Section 108.3� Project Information John and Wend Evans Electrical Square Footage 62$ Owner Name: y Parcel #: /.�(1 l� Q� I— O� — O l� (For Parcel #, contact Eagle County Assessors Office at (970328-8640 or visit www.eaglecounty.us/patie) Detailed Scope and Location of Work: Installation of Six new recessed can lights in unit. (use additional sheet if necessary) For Office Use Only: Fee Paid: ��?+�,�5 Received From: fd�GN Mrnt I�oMES Cash Check #� a 5 7� CC: Visa / MC Last 4 CC # exp date: Auth # Date Received: � � � � � � � �ocr z � z�» I� TOWN OF VAIL 01-]an-I1 G Service Calculation Lighting Demand Load Square Footage Small Appliance Laundry Circuit First 3000w @ 100% Next 3001 to 120000 @ 35% Remainder @ 25% A/C and Heat Demand Air Conditioning Load 240V 3hp 2.5 ton Air Conditioning Total Electric Heat Load 240V Electric Heat Total Electric Heat Larger omit air conditioning 1 of 3 10/17/2011 2 1 630 1500 1500 Total Load Total Lighting Demand =______> Qua KVA Total 0 4.5 0 0 0 3 0.75 2 0 0 0 2 Total Heat vs. Air Conditioning=> line 1890 3000 1500 6390 3000 1187 0 4187 2250 neutral 1890 3000 1500 6390 3000 1186.5 0 4186.5 Appliance Fastened in Place Dishwasher Disposal Refrigerator Under Cabinet Refrig Whirlpool Tub Hot Tub Boiler Pump Insta Hot M i c rowave compactor Fan blower audio visual equipment washer gas dryer Boiler Steam Unit Exhaust Fans fan coil unit humidifier fan coil unit Heat Tape Total Appliance (75% for 4 or more) 2 of 3 10/17/2011 Voltage 120 120 120 120 120 240 120 120 120 120 240 120 120 120 120 240 120 240 240 240 240 Qua 1 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 Watts 1600 1200 1500 1000 1900 5000 200 600 800 1200 100 700 1500 1500 500 6000 200 800 1800 500 2000 Line 1600 1200 1500 0 0 0 0 0 800 0 0 0 0 0 0 0 200 0 0 0 0 0 0 0 5300 Neutral 1600 1200 1500 0 0 0 0 0 800 0 0 0 0 0 0 0 200 0 0 0 0 0 0 0 5300 3975 3975 EIec.Clothes Dryer (5Kw min) Demand Factor % (220-18) Electric Cooking Equipment Demand Factor Kw (220-19) Largest Motor * 25% volts , watts Total Demand line Total Demand Neutral Line Amperage Demand Neutral Amperage 220-22 First 200 at 100% Remainder at 70% Neutral Amperage Demand System Voltage H,L Service Size =___» Conductor Type AL or CU Wire Size per 310-16 note 3 Service lateral length in feet Resistance per ft. in ohms==> Percentage of voltage drop Wire Size per voltage drop Wire size 3 of 3 10/17/2011 1 5000 100% 6.4 120 300 240 120 100 al 2 AL XHHW 100 21.2 3 #N/A AL XHHW #N/A AL XHHW 5000 3500 6400 4480 75 75 21887 16217 91 ss 68 0 68 �r„ �;;... , :.- �.:����� �,: ��V�� � , ���lIF � �.�i� �CilGe.:. � �� � ��--- � + i ° ei' a� �'`'' ��6 �� �.- ���,� GA FILE NO. FC 5111 , �����, f� �.� 3 GENERIC WOOD I-JOI,RTB, GYPSUM WALLBOARD, �SM.IENT CHANNELS Baae �yer �)z" tyrye X gypsum watlboard appl�d at rlgM engles to reslpeM channels 16 o.c. with 1�1a" Type S drywad screws 12" o.c, ResiYent channels applled at rlght angles to mk�lmum 9+ls" deep wood I-Jolsts, wNh minimum t�la" deep x 1 Vz" wide flanges and minimum ala" webs, 24" o.a wfth t+la" Type W drywall screwa, Faee layer +/z" type X gypsum waYboard apptled at dght angles fa channels wtth t�/a' Type S drywall screws 12" o.c. Face layer end )oiMs bcated mldway behveen channels and stlached ta base layer wNh t+lz" Type G scraws 12" o c Edge JWnts offset 24" from base layer edge jol�s. Wood I-joists suRPoAing �!s" orlented strantl board applled at dght angles to I- Joists wlth 8d cammon nalls 12" o.c. STC antl f IC tested wlth 40 oz cerpst over'la" foam ped. 1 1 HOUR FIRE . _� .__ __ �� ls � Approx, CetNng Weight: Flra Test 3ound Test: IIC & Test: 5 psf NRCCA-4440.1 (Revlaed� 6-24-97 NRCC B-3150,2, 6-30-00 (68 C & P) NRCC B-3150.2, 6-30-00 NOTES: COORDINATE LOCATION OF RECESSED CAN LIGHTING WITH EXISTING STRUCTURE. USE TENMAT RATED LIGHTING ENCLOSURE. MAINTAIN THE EXISTING 1 HOUR RATED UNIT SEPARATION. 2. NEW RECESSED CAN ARE TO BE ON EXISTING CIRCUITS 1 G� !ln �„ �CUCivv: sPr FIRE SPRINKLER (EXISTING) sm SMOKE DETECTOR (EXISTING) �Q RECESSED CAN LIGHT FIXTURE (NEV� � EXISTING RECESSED CAN TO REMAIN � EXISTING COVER PLATE OVER JUNC. BOX TO REMAIN `!' � '`i ,. I�, � OCT 1'� 1�;? i' Ll��; �C�711VN OF VAIL � 1 � r ,� s � Unit 266 PLAN SCALE: 1 /4" s � �_p� — } W Z �$ Q� � o� � �U o �� � � � N W � c _ � ro ■ZU � �� � � x� — Q �, m � FN °� a LL Q L � � Lci � � � N °° 0 -�.� � '� o � o W (� � N � W �� . � p � •� � W�� > � �' 0" i J L —� O � � J ` V � � � � � � N � � � � � 0 � � � � Q c a� � o a � � � � `� �. � . 11-07-2011 Inspection Request Re�orti Vail Cn _ Ci+v (� � Requested Inspect Date: Tuesday, November 08 2011 Site Address: 595 VAIL VALLEY DR �AIL MANOR VAIL LODGE UNIT 266 A/P/D Information Activity: B11-0442 Type: COMBO Sub Type: AMF Const Type: Occupancy: Use: Owner: DUFFIELD, MARTYN E. Contractor: HIGH MOUNTAIN HOMES, INC Phone: 970-376-5475 Description: INSTALLATION OF SIX NEW CAN LIGHTS IN UNIT. Requested Inspection(s) Item: 90 BLDG-Final Requestor: HIGH MOUNTAIN HOMES, INC Comments: 376-5475 Assigned To: **""" "`* Action: Time Exp: Item: 190 ELEC-Final Requestor: HIGH MOUNTAIN HOMES, INC Comments: 376-5475 Assigned To: S E Action: Time Exp: c% �� Page 17 Status: ISSUED Insp Area: Requested Time: 02:00 PM Phone: 970-376-5475 Entered By: JMONDRAGON K Requested Time: 09:00 AM Phone: 970-376-5475 Entered By: JMONDRAGON K InspeCtion Historv Item: 120 ELEC-Rough "" Approved "" 11/02/1 T Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC-Final Item: 90 BLDG-Final REPT131 Run Id: 13762