Loading...
HomeMy WebLinkAboutB11-0444NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES -.� �ow� o��� � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0444 Job Address: 2586 DAVOS TR VAIL Location......: side B Parcel No....: 210314204003 OWNER WILLIAM R. AYLESWORTH TRUST 10/21/2011 333 N CANAL 1804 CHICAGO IL 60606 CONTRACTOR RISING SUN DEVELOPMENT, INC. 10/21/2011 PO BOX 1348 EDWARDS COLORADO 81632 License: 321-A Phone:(970)328-3744 APPLICANT STEVE FRANCIS 10/21/2011 Phone: 970-331-4918 PO BOX 255 WOLCOTT CO 81655 Description: GARAGE AND BREEZEWAY ADDITION, DRIVEWAY CONSTRUCTION, WINDOW WELL (2) INSTALLATION, HEATED DRIVE INSTALLATION, LANDSCAPING ALTERATIONS Occupancy: R-3 Type Construction: VB Project #: Applied.....: Issued. . . : PRJ 11-0469 10/21 /2011 11 /09/2011 Valuation: $116,500.00 ..............,....,.,...,...............,.�.........................,.,.......... FEE SUMMARY ..,..........,�.....,,..................,................._......,,...........». Building Permit -----------> $1,088.95 Bldg Plan Check ----------> $707.82 Use Tax Fee-----------------------> $2,130.00 Electrical Permit ---------> $115.00 Elec Plan Check -----------> $74.75 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $300.00 Mech Plan Check ---------> $75.00 Additional Fees--------------------> $0.00 Plumbing Permit --------> $0.00 Plmb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $15.00 TOTAL PERMIT FEES-------------> $4,506.52 Payments------------------------------> $4,506.52 BALANCE DUE-----------------------> $0.00 .................................�....................,,,,<,..»..........».....................,.....,.......,..<,......«.»......................,,,...................,.,.....,..,,.. DECLARATIONS I hereby acknowledge that I have read this application, fiiled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQU TS FOR INSPECTION SH LL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 A 4:00 PM. / l ignature of Owner or Contr� tor � Da e � Print Name combination permit_012811 f � � I� �� �� ! .+...+.x......+x..x .................x..s......x....r....v,...+.xx........+...x.......>......x......xx..x.....a..x.++.xx....+.............e:r:r...........+.....r....+...++...«.+..+:..... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11-0444 Address: 2586 DAVOS TR VAIL Owner: WILLIAM R. AYLESWORTH TRUST - LINDA W. AYLESWORTH TRUST Location: side B ...........................................................................«..,,,...,................,.,.......�.......�.....,....�......,...........,........,.,..........,.......... Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 Cond: CON0012271 upgrade house to monitored fire alarm system combination permit_012811 � � TO�V� OF Y,� . .*******************,*****************************.**w��*****,************************x*�**.**w***�***.*,,,,*.,**.,.,*******************.**,***,****„**** REQUIRED INSPECTIONS AND STATUSES Permit #: B11-0444 Address: 2586 DAVOS TR VAIL Owner: WILLIAM R. AYLESWORTH TRUST - LINDA W. AYLESWORTH TRUST Location: side B *.,,***,..**********«***.*******�******,,*,.**«*.,********«***„**«***.,.,************�****,.**************«**.,�*****************«.,********«*„«««**********«** Item: 00010 BLDG-FOOTING Item: 00020 BLDG-Foundation/Steel Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00240 PLMB-Gas Piping Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00021 PLAN-ILC Foundation Plan Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00190 ELEC-Final Item: 00090 BLDG-Final Item: 00534 PLAN - FINAL C/O combination permit_012811 *****�*****************************************�******************�**************�********** TOWN OF VAIL, COLORADO Statement **********************�***********************************�**************�**********+******* Statement Number: R110001634 Amount: $4,111.06 11/09/201101:53 PM Payment Method: Check Init: SAB Notation: 4712 - STEVE/JEANETTE FRANCIS ----------------------------------------------------------------------------- Permit No: B11-0444 Type: COMBINATION BLDG PERMIT Parcel No: 2103-142-0400-3 Site Address: 2586 DAVOS TR VAIL Location: side B Total Fees: $4,506.52 This Payment: $4,111.06 Total ALL Pmts: $4,506.52 Balance: $0.00 *******************�***�****************************�*************************************** ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 EP 00100003111100 MP 00100003111100 PF 00100003112300 UT 11000003106000 WC 00100003112800 Description ------------------------------ BUILDING PERMIT FEES ELECTRICAL PERMIT FEES MECHANICAL PERMIT FEES PLAN CHECK FEES USE TAX 4% WILL CALL INSPECTION FEE Current Pmts 1,088.95 115.00 300.00 462.11 2,130.00 15.00 ----------------------------------------------------------------------------- TOWN OF VA1L� Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Revision Submittals: 1. "Field SeY' of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re-issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: Attention: �t � -��y � Project Street Address: s��� �� (Number) (Street) (Suite #) Building/Complex Name: ��'10-rd-P�,Q_. ¢�.����y�, ( ) Revisions ( ) Response to Correction Letter attached copy of correction letter ( ) Deferred Submittal ( i�� �=L� �v���'� ` Description / List of Changes: ; � �d.o�� v�. � L-�_ Contractor Informa ' n Business Name: �� ���-n-�-lS Business Address: �� �� Z�� City V vO �� � State: C�.� Zip: �LC� �' Contact Name: /�� , (,�p� ' (use additional sheet if necessary) Contact Phone: v1��� l �t-c,"1 4� � .., . _._:� . �_ � _ ....... . ........ ..., , _,.. .._ . .. � .. . ,.:.. �' j� • A_ p� �� , Revised ADDITIONAL Valuations (Labor & Materials) Conta -Mail: .��� �i1.� � JtJ�-c � . y�..� +(��D�OT include original valuation) X - �'�-��.�,�� Building: $ s Representative Signature (Required) Applicant I formation Applicant Name: ��1��1_ :. rP 1-P Q tn� -1��a� �/�-�1.� Applicant Phone: 3 � � Applicant E-Mail: For Office Use Only: Fee Paid: Re�eived From: Cash Check # _ , CC: Visa / MC Last 4 CC # I Auth # exp. date: Plumbing: Electrical: Mechanical: Total: Date Received: 1 $ $ $ .� ECE�V E APR 13 2012 ��/JW� iOWN �F vA� o � -o�c-> > : ��.> iVYVi�� i1I '1Af�:a , Depariment of Commus�ity Dev�;apment 75 South Frontag� Road Vail, CO 8'€ 657 Tel: 970-479-2'i 28 www.va+igov.com Development Review Coordinator TRAiVSMITTAL FORM Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re-issued. 3. Fees for reviewing revisions are 355.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s} information applies to: Attention: () R isions �I � , _ , , t ��l � ( onse to Correction Letter q�[�.la �} �� _aftached copy of correction letter -l� � � � ( ) Deferred Submittal Q (,v � ( ) Other Project Street Address: ? s8T '(�/os '�Arl (Number) (Street) (Suite #) ` �' gsci i� ; / Li�Changes: BuildingJComplex Name: � Y �� � �I4� Contractor Informatio � Business Name: "e�� � Business Address: � �� �� City V �"J � � State: � Zip: ��� Contact Name: v 1�� C.�,S � �D ���� � � � � (use additional sheet if necessary) Contact Phone: _ .,-. _ �..�.1 v� �� Revised ADDITIONAL Valuations (Labor 8� Materials) Con ct E-Mail: ��V'e-� � � I(�DO NOT include original valuatio^� �- � w �..... Building: Owner/Owner s Representative Signature (Required) Plumbing: Applicant Information - � � � Electrical: Applicant Name: w��t�r�� Mechanical: Appiicant Phone: �� " r' � � . Total: Applicant E-Mail: � er For Office Use Only: Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # Auth � rn�c, La� exp. date: Date Received: C �jG �. � V � I',, � NOV Q 2 2011 ,, � TOWN OF VAIL or-o��-, � Date: 11/1/2011 Re: B11-0444 2586 Davos Trail Dear Mr. Francis, RESPONSE INSTRUCTIONS • Submit three complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. • Please respond in writing to each comment with a response letter addressing each comment. BUILDING COMMENTS Architectural Comments: Sheet 1 1. Structural sheets show a proposed foundation drain. Grading plan does not reflect proposed drain. Please show on plans and indicate termination point. Reference section 1805.4.3 IBC drain will day-light onto the ground at the appropriate elevation. approximate location presented on drawing # 1 Sheet 2 1. Plan indicates a heated drive. Is this new? If so please show separate zones for heated portions within the Town of Vail right of way heated drive is new along with heating system for same. the 48" apron at the edge of the roadway will be heated with a separate heat zone shown on drawing # 2 2. Plans indicate new egress window wells. Provide plans showing compliance for egress ladders and clearances as required by section 310.2 IRC. i have provided the specifications for this egress window on plan sheet # 2. also provided is cut sheet for the window and window well. Sheet 4 1. Provide a cross sectional detail of the proposed stair in order to verify compliance for rise and run of the stairs, head room clearances, guard opening limitations, and handrail design as well as location. Reference sections R311 and 312 IRC. this cross section, B-B, has been provided on sheet # 7 detailing this stair area Sheet 7 1. Proposed roof system to be a Class A roof system. Please clarify on plans the roof Town of Vail Page1 system proposed is a Class A roof system. the system is detailed on sheet # 7 and does meet class A requirements and matches the existing roof system on the residence. 2. Plans do not reflect a ventilated roof. If the roof is to be ventilated show vent locations and size. If roof is not ventilated show compliance with section 1203.2.1 IRC as amended by the Town of Vail. i have detailed this vent system for the new garage on sheet # 7, this includes a ridge vent and sofit vent system. 3. Plans do not reflect the required weather protection of building per section 1404.2 IBC. Revise plans to reflect the required weather resistive barrier. i have further detailed the required items on sheet # 7, this includes vapor barrier, exterior coverage with Tyvek, attic insulation baffels. Structural Comments: Reviewed and accepted Plumbing Comments: See foundation drain requirements Mechanical Comments: Sheet 7 1. Plans reflect the termination of the proposed vent in noncompliance with section 503.6.4 IFGC as amended by the Town of Vail. Vent must be a minimum of 60" above grade. this vent termination is detailed on sheet # 6, which shows the vent to terminate through the exterior wall at approximately 72" above the finished grade 2. Plans to reflect proposed boiler to be a minimum of 92% high efficiency this boiler specification is further detailed on sheet # 7, this is a high performance boiler and does meet requirements 3. Provide gas piping plans showing compliance with section 402 of the IFGC. See Town of Vail submittal requirements as well. the gas pipe is detailed on sheet # 2 and will be installed underground from the meter location to the boiler location. Electrical Comments: Sheet 7 1. Annotate on plans that the carbon monoxide detection devices are to be installed per Town of Vail Page2 section R315 IRC. this is a garage that is removed from the living area of the residence and bedrooms, the only connection is a common wall only, the entry to the residence and from the garages are to the exterior walkway with no enclosed connection. PLANNING COMMENTS FIRE COMMENTS PUBLIC WORKS COMMENTS Sincerely, Martin A. Haeberle Chief Building Official Town of Vail Page3 B�sement Window Wells: Sizes Of Basement Window Wells � Photo & Chart Page 1 of 1 ��C=t LI�� � ���� �� � �t ���;� � WINDOW WELLS > CONTACT US �..� � _. , �+*- HOfw1E PRODUCTS � DISTRI4U`PC3i�iar, ;: � . RESC}U � �, , �.,. GAi,LERY�e� �iiii (��� k� � ' .. �, �, ,. ,,s �� " � � .�. �-,..._ ,. �� K r. . P� >.� �...au�ro .a�. . � y,�,. � ASOUT US � CONTACT US .',�°� �� � � '�j�f � m i'il" � ' .� �� 4:� ,� � , . ��� s. � ' . "��•'!P � �� � , ° � . ��� , ;i� . �,�„� . . � 4 ^ae �j � ' r � � % , • �����.'... ' � � � � Y' i � - � d ; %Y � � ae► � .� � '�.� > � � ; ys_ �r .�f, # , K ` , . . ' � ,.y � �� , �� � '•�,����� � � ,� � 4 ' '�,.b" � �T � Y��. ` . , ,� �, .`fwf � .�"'._ �� _ �.�1��.� � ` s ��",3 � e2.� � � : � tl : . �"-; w 3 ..r � ` �'' .�r� rr � , ' � . � �; � �� i: �i+ Menc� _ _. WELLS ► elite wells ► premier wells ► cascade wells ACCESSORI£S ► covers ► grates ► ladders (ogtional) INFORMATTON ► praductfeatures ► safety ► warranty ► builder resources r literalure ELITE SERIES RockWell window wells have a stone texture that truly looks and feels like real stone. Adding great curb appeal and an aesthetically pleasing view from the inside out. Our wells also allow for more light into an otherwise dark & d2b basement. , Elite Series '�� x� Item W�d� Projection Height Weight (Inside) (��� WEf-664472 66 44 72 105 w�-c�aas�a c� qa sa 125 WE�-664�1� 66 44 96 145 Note: All dimensans are in inches Steps are 16 indies on center Flange widths are 4.5 inches Examples: WET-664472=Well, Multi-Step, Tan, 66x44x72 WEG-664484=Well, Multi-Step, Grey, 66x44x84 �t:�:��'�`���r.i�����wr.�i� � a� � .,a,.�, � 4m� .�,,. -= � �_�JR+C'rALLE�Y ► , t .� �:�� �� �::�- �� .�a� �;a ��� :�'� Copyrght 2011 RakWdl Window Wdls. NI RlghtS Reserved. HpME PRODURS GALLERY DISTRIBUTORS RESOURCES ABOUT US COt�liACi US PatenteE Te[hndogy WINDOW WELLS EGRE55 WINDOW WELLS BlSEMENi WINDOW WELL B0.5EMEN7 EGRESS WiNDOW WELLS http://www.rockwellinc.com/windowWellSizesB. html 11 /2/2011 � -_ E ; _ _'_. ❑ s� 0 �� ���� ��� 0 a �r�c �.i; ` � �! . � � ___. .___.__ _ __ ... __ _ ___............ . . ., . . . ....... .....A ' • ' � � CJ V � h7 ° i i 9 ' i=- � ❑ lJ a u 0 0 �� . � �edi-Exit offers egress windows, egress window wells, fire escape ladders, fire doors, cha... Page 1 of 3 Home About Us Articles Testimonials Egress Windows Egress Windows Compact Single Hung In-Swing Egress Egress Window Welts W�ndows Sliding Basement Egress Windows Fire, Exterior, Interior Doors Casement In-5wing Egress Windows Contad Us Sitemap Acrylic Block Casement Style In-Swing Egress Windows Casement Out-Swing Egress Windows Instailation Guidelines Photo Gallery Fire Escape Ladders Overview Fire Escape Piatforms Few of us think of windows as lifesaving equipment, but they are! Bedroom Smoke Aiarrns windows that are properly equipped for egress in the event of an emergency can be the difference between life and death. Carbon Monoxide Alarms 3,500 to 4,000 peopie perish in home fires annually; in addition to the 15,000 Talking Smoke Alarms to 21,000 who are injured. Haif of these deaths occur at night when people are asleep and get trapped in their bedroom without a second way out in the event Biico Basement Doocs smoke or fire blocks their normal escape route. Related Links Since September 1973, building codes require that in all new construction or when remodeling, every sleeping room have at least one operable window with a clear opening of 5.7 square feet to act as an egress window during an emergency. The code also requires that basement family rooms, basement bedrooms and basement apartments have a second way-out such as a Basement Egress Window and Basement Egress Well System. It also requires that the maximum allowable distance from the floor to the egress window sill is no more than 44 inches in order to be acceptable as an emergency escape or egress window. NOTE: It is the responsibility of the owner, architect, contractor and or builder to select products that compiy with applicable, state and local building codes and that is appropriate for the application and use, A building permit probability witl be needed. REDI-EXITp Compact Single Hung In-swing Egress Windows REDDCO'S REDI-EXITQ Compact Single Hung In-swing Egress Windows are the smallest windows designed to meet or exceed the emergency egress window requirements of the IRC 2006 code. They can be used for new or replacement construction in above ground or basement applications. ;: � ��'e a� These dual function vinyl windows operate in two ways; 1} as a normal single hung window, with the lower sash opening for ventilation; 2) in the event of an emergency, a latch in the corner of the window is opened and the top and bottom sashes hinge into the room like a door giving you 5.7 square feet of clear area for escape. Since both the top and bottom of the window opens up it gives you twice the square feet of clear area that you would get from a standard double hung window that doesn't hinge into the room. �-- These egress windows come in four stock sizes; 28" wide X 46" high X 3 1/4" deep, 35 1/2 wide x 36 high x 3 1/4 deep, 31" wide X 41" high X 3 1J4" deep and '" j�' 35 1/2" wide X 53 1/2" high X 3 1/4" deep are available with a right or left hinge, � for immediate delivery. Custom sized windows can be special ordered in 1/4" ' increments to fit any size requirements. � A Fiberglass Half Screen comes standard or an optional Stainless Steel Security Screen is also available. Our stock Egress windows are supplied in white but are also available in beige vinyl. These emergency escape windows can be custom built with grids or lites in both the upper and lower � window sections to match your home. Tempered glass is available. We also offer Low-e Glass http://www.redi-exit.com/egress-windows.html 11 /2/2011 A Reliable Fire Escape Ladder at Redi-Exit Fire Escape System Page 1 of 1 Home About Us Articles Testimoniais Contact Us Sitemap Egress Window Features & Benefits Egress Windows . New construction and replacement units • Standard 3.25" mainframe for easy installation Egress Window Welis . All glazing options available • Available in custom sizes Fire, E�erior, Interior . One hand release multi-point exit in case of emergency Daors . Available with left or right swing fire Escape Ladders � All vinyl construction for warmer surface temperatures Available in white or beige • Standard fiberglass screen or optional stainless steel security screen Fire Escape Platforms . passed forced entry resistance: AAMA 130Z.5 • Overall product rating: H- R25 - 48X72 Smoke Alarms Call us today at (866) 996-1989 to get a free quote for egress windows! Carbon Monoxide Alarms Egress Windows > Taiking Smoke Alarms Egress Window Wells > Egress Window Well Covers > eilco Basement Doors Grate Style Egress Window Weil Covers > Window Weil Egress Ladders > Related Links BaCk to Overview This site created and promoted on the web by DR McMahon & Associates, Inc. http://www.redi-exit.com/egress-windows-features.html 11 /2/2011 TOWN OF UAI!' Project Street Address: 2586 Davos Trail Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) (Number) (Street) (Suite #) Building/Complex Name: Vail Das Schone Fil:1 blk:4 Lot 4 Contractor Information eusiness Name: Steve Francis Business Address: P.O. Box 255 City Wolcott State: CO ZiP: 81655 Contact Name: Steve Francis Contact Phone: 970-331-4920 Contact E-Mail: stevebuildsvail@gmail.com _��-� Owner/Own re s Representative Signature (Required) Applicant Information Applicant Name: Linda and Bill Aylesworth Applicant Phone: 630-347-0808 Applicant E-Mail: merleayles@me.com Project #: 1'"KJ j L„ oRe#: n2E�1! o3Sa Building Permit #: !7� I + �'1 � � Lot #: Block # Subdivision: Work Class: New ( ) Addition ( ✓ ) Alteration ( ) Type of Building: Single-Family ( ) Duplex ( ✓ ) Multi-Family ( ) Commercial ( ) Other ( ) Work Type: Interior () Exterior (✓) Both () Valuation of Work included Plans Included Work Electrical ( )Yes ( )No ( Yes ( )No lS�� Mechanical ( )Yes ( )No ( �'4es ( )No �5�� Plumbing ( )Yes ( )No ( )Yes ( )No '�" Building ( )Yes ( )No ( /jYes ( )No 3� ^ �'Qp Value of all work being performed: $ �� (value base^J on IBC Section 109.3 & IRC Section 108.3) Project Information William R. Aylesworth Trust Electricai Square Footage Owner Name: Parcel #: 2103-142-04-003 (For Parcel #, contact Eagle County Assessors Office at (970-328-8640 or visit www.eaglecou nty.us/patie) Detailed Scope and Location of Work: Adding a Carport and Breezeway (use additional sheet if necessary) For Office Use Only: Fee Paid: ���J'�.�� Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Date Received: -- _.._ . ___._.___.__. � _ !� � D �L l � �_� � � \�i ; � � . OCT 18 2��1 � �OWN OF VAIL O1-1an-11 1 . �, �� 07-17-2012 Inspection Request Reporting Page 9 4:13 pm Vail, C_ _� �f Requested Inspect Date: Wednesday July 18 2012 Site Address: 2586 DAVVS� TR VA�L side B A/P/D Information Activity: B11-0444 Type: COMBO Sub Type: ADUP Status: ISSUED Const Type: Occu ancy : Use: R-3 Insp Area: Owner: WILLIAM R. AYLESWOR�H TRUST - LINDA W. AYLESWORTH TRUST Contractor: RISING SUN DEVELOPMENT, INC. Phone: (970) 328-3744 Description: GARAGE AND BREEZEWAY ADDITION DRIVEWAY CONSTRUCTION WINDOW WELL (2) INSTALLATION, HEATED DRIVE INSTAL�ATION, LANDSCAPING ALTEF'tATIONS Reauested Inspection(s) Item: 90 BL Requestor: RISIN( Comments: 331-4� Assigned To: JI�(I�11 Action: __� Comment: Lo6i�e PMENT, INC. Time Exp: �rs in � Item: 190 EL GFina ��� ����/� Requestor: RISING SUN DEVEL�PMENT,INVC. Comments: 331-4918 Assigned To: JMON Action: Time Exp: Item: 290 PLMB-Final Requestor: RISING SUN DEVELOPMENT, INC. Comments: 331-4918 Assigned To: JMON Action: Time Exp: Item: 390 MECH-Final Requestor: RISING SUN DEVELOPMENT, INC. Comments: 331-4918 Assigned To: JMO ON Action: Time Exp: Comment: Inspection Historv Item: 10 BLDG-FOOTING *" Approved "* 11/17/11 Inspector: Martin Comment: 12/02/11 Ins pector: JRM Comment: RETAINING WALL FOOTER Item: 20 BLDG-Foundation/Steel *"' Approved """ 11/23/11 Inspector: JRM Requested Time: 04:00 PM Phone: (970) 328-3744 Entered By: JMONDRAGON K Requested Time: 03:30 PM Phone: (970) 328-3744 Entered By: JMONDRAGON K Requeste Phone: (970j 328-3744 Entered By: JMONDRAGON K Requested Time: 03:00 PM Phone: (970) 328-3744 Entered By: JMONDRAGON K Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED REPT131 Run Id: 14646 07-26-2012 inspection Request Re orting Page 6 4:3�_m �J�iI,�Q—�it� --- Requested Inspect Date: Friday, July 27, 2012 Site Address: 2586 DAVOS TR VAIL side B A/P/D Information Activity: 611-0444 Type: COMBO Sub Type: ADUP Const Type: Occu� pancy� Use: R-3 Owner: WILLIAM R. AYLESWORTH TRUST - LINDA W. AYLESWORTH TRUST Contractor: RISING SUN DEVELOPMENT, INC. Phone: (970) 328-3744 Status: ISSUED Insp Area: Description: GARAGE AND BREEZEWAY ADDITION DRIVEWAY CONSTRUCTION WINDOW WELL (2) INSTALLATION, HEATED DRIVE INSTALLATION, LANDSCAPING ALTEF2ATIONS Requested Inspection(s) Item: 534 PLAN - FINAL C/O Requestor: RISING SUN DEVELOPMENT, INC. Comments: 3PM OR LATER REQUESTED. Assigned To: BGIBSON Action: Time Exp: _ �pp�d� f�G ��i�%Z Inspection Historv Requested Time: 08:15 AM Phone: 331-4918 Entered By: DRHOADES K Item: 10 BLDG-FOOTING "` Approved " 11/17/11 Inspector: Martin Action: AP APPROVED Comment: 12/02/11 Inspector: JRM Action: AP APPROVED Comment: RETAINING WALL FOOTER Item: 20 BLDG-Foundation/Steel '" Approved ** 11/23/11 Inspector: JRM Action: AP APPROVED Comment: 12/06/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 120 ELEC-Rou h '* Approved *' 02/06/12 Inspector: sqremmer Action: PI PARTIAL INSPECTION Comment: all ok still nee7 to see the panel completed 07/13/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rouqh '"` Approved " 04/04/12- Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: qarage in floor heat only tested at 100 psi 04/25/12 fnspector: sgremmer Action: PI PARTIAL INSPECTION Comment: Dnveway snow melt tested at 100psi 06/26/12 Inspector: sgremmer Action: AP APPROVED Comment: driveway snowmelt tested at 100 psi Item: 240 PLMB-Gas Piping "* Approved "` 04/25/12 lnspector: sgremmer Action: AP APPROVED Comment: air iest at 15 �si ok for meter release Item: 30 BLDG-Framing * Approved "` 04/17/12 Ins�pector: mdenney Action: AP APPROVED Comment: 2 Conditions Stair tread depth shall not vary more than 3/8". Clearance to untreated lumber shall be a minimum of 6". Item: 50 BLDG-Insulation " Approved '� 04/17l12 Inspector: mdenney Comment: Item: 60 BLDG-Sheetrock Nail ** Approved "' 04/20/12 Inspector: Martin REPT131 Action: AP APPROVED Action: AP APPROVED Run Id: 14660 I 01-07-2013 Inspection Request va�i r_n _ ��t� Page 11 Requested Inspect Date•' Tuesday January 08, 2013 Site Address 2586 DA�IOS TR VAIL side B A/P/D Information Activity: B11-0444 Type: CO BO Sub Type: ADUP Status: ISSUED Const Type: Occu ancy : Use: R-3 Insp Area: Owner: WILLIAM R. AYLESWOR�H TRUST - L NDA W. AYLESWORTH TRUST Contractor: RISING SUN DEVELOPMENT, INC. Phone: (970) 328-3744 Description: GARAGE ANDBREEZEWAYADDITIO DRIVEWAYCONSTRUCTION WINDOW WELL(2) INSTALLATION, HEATED DRIVE INSTA ATION, LANDSCAPING ALTEF�ATIONS Reauested Insaection(s) Rem: 90 BLDG-Final Requestor: Comments: follow u � Assigned To: SGR Action: Time Exp: Comment: ou detectors in Comment: Plann to sign off Requested Time: 04:00 PM Phone: Entered By: JMONDRAGON K Ins�ection Historv Item: 10 BLDG-FOOTING *' Approved" 11/17/11 Inspector: Martm Action: AP APPROVED Comment: 12/02/11 Ins ector: JRM Action: AP APPROVED Comment: R�AINING WALL FOOTER ftem: 20 BLDG-Foundation/Steel "' Approved " 11/23/11 Inspector: JRM Action: AP APPROVED Comment: 12/06/11 Inspector: sgremmer Action: AP APPROVED Comment: ftem: 120 ELEC-Rough '" Approved " 02/06/12 Inspector: sg remmer Action: PI PARTIAL INSPECTION Comment: all ok still needto see the panel completed 07/13/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough " Approved '" 04/04/1Z Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: garage in floor heat ony tested at 100 psi 04/25/12 fnspector: sgremmer Action: PI PARTIAL INSPECTION Comment: Driveway snow melt tested at 100psi 06/26/12 Inspector: sgremmer Action: AP APPROVED Comment: driveway snowmeR tested at 100 psi Item: 240 PLMB-Gas Piping " Approved " 04/25/12 Inspector: sgremmer Action: AP APPROVED Comment: air test at 15 �si ok for meter release Item: 30 BLDG-Framing ' Approved'" 04/17/12 Insp ector: mdenney Action: AP APPROVED Comment: 2 Conditions Stair tread depth shall not vary more than 3/8". Clearance to untreated lumber shall be a minimum of 6". ftem: 50 BLDG-Insulation 04/17/12 Inspector: Comment: Item: 60 BLDG-Sheetrock Nail 04/20/12 Inspector: Comment: Item: 21 PLAN-ILC Foundation Plan '" Approved " mdenney '• Approved " Martin " Approved " Action: AP APPROVED Action: AP APPROVED REPT131 Run Id: 14626