HomeMy WebLinkAboutA10-0045 Fire Alarm System Record of Completion Solaris Unit 204/ -ot FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY INFORMATION Name of SOLARIS — UNIT 204 property: Address: 141 EAST MEADOW DRIVE, VAIL CO Description of MDG;D USE — HIGH RISE property: Occupancy type: M Name of property SOLARIS PROPERTY OWNER - SPO representative: Address: Phone: 970.390.6493 Fax: E -mail: DAN.FEENEY @SOLARISVAIL.COM Authority having jurisdiction over this VAIL FIRE DEPARTMENT property: Phone: 970.479.2135 Fax: E -mail: MMCGEE @VAIL.GOV 2. FIRE ALARM SYSTEM INSTALLATION, SERVICE, AND TESTING INFORMATION Installation contractor for this equipment: Superior Alarm Address: aV 'EOtAiAP_hS vii G44.Q& D _dD. Phone: 1.800.753.4524 Phone: 1.800.753.4524 Phone: g70 - 9 L(. 8 ?SS Fax: J579 E- mail: M� lQE„�'JkJFZJ SAG wj e cl e00 Service organization for this equipment: JOHNSON CONTROLS, INC. Address: 10289 WEST CENTENNIAL ROAD, LITTLETON, CO 80127 Phone: 303.973.5930 Fax: 303.979.6847 E -mail: KENNETH.D.BALL @JCI.COM Location of as -built drawings: FIRE COMMAND Location of historical test reports: FIRE COMMAND Location of system operation and maintenance manuals: FIRE COMMAND A contract for test and inspection in accordance with NFPA standards is in effect as of: Contracted testing company Address: TBD Phone: TBD :p E -mail: TBD Fax: TBD Occupancy type: F B,M,S Contract expires: TBD Contract number: TBD Frequency of routine inspections: TBD 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter Reference of System Type: CHAPTER 6 Name of organization receiving alarm signals with phone numbers (if applicable): Alarm: REMOTE OPERATIONS CENTER - JCI Supervisory: REMOTE OPERATIONS CENTER - JCI Trouble: REMOTE OPERATIONS CENTER - JCI Entity to which alarms are retransmitted: VAIL FIRE DEPARTMENT DISP Phone: 970,479,2246 Method of retransmission of alarms to that organization or location: Phone Centeral Station Dispatch Record of Completion forth (based on NFPA 72 - 2007) NFPA 72, 1 of 5 NFPA Unit 101.doc 6/1/20101134:00 AM R-W. Evans Reprinted with permission from NFAP 72 -2007, National Fire Alarm Code ®, Copyright 0 2007, National Fire Protection Association, Quincy, MA, 02269 iox 1610 TBD — UPON C/O of Solaris Phone: 1.800.753.4524 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE (condnueo If Chapter 8, note the means of transmission from protected premises to the central station: ❑X Digital alarm communicator ❑ McCulloh ❑ Multiplex 0 2 - way radio 1 - way radio If Chapter 9, note type of connection: F Local energy F Shunt ❑X N/A 3.1 System Software Operating system (executive) software revision level Site - specific software revision date: 5.9 12.0 E] N/A Revision completed by: JIM MOREN 4. SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to this system (see NFPA 72, Table 6.6.1): Quantity: 1 Style: 4 Class: B 5. ALARM INITIATING DEVICE CIRCUITS Characteristics of initiating device circuits connected to this system (see NFPA 72, Table 6 S): TO BE REMOVED PRIOR TO CIO (TEMPORARY RETAIL SEE BELO*) - EACH HEAT IN GARAGE ON INDIVIDUAL IDC Quantity: 0 Style: na Class: na 5.1 Manual Initiating Devices 5.1.1 Manual Pull Stations Number of Manual pull stations: 3 Type of devices: ❑X Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: 7 Type of coverage: F Complete area ❑X Partial area Nonrequired partial area ❑ N/A Type of devices: FX Addressable F_� Conventional Coded ❑ Transmitter F N/A Type of smoke detector sensing technology F Ionization ❑X Photoelectric 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: 0 Type of coverage: Type of devices: ❑ Addressable Fj Conventional Coded Transmitter N/A Type of smoke detector sensing technology F Ionization Photoelectric 5.2.3 Heat Detectors Type of coverage: F Complete area FX Partial area Type of devices: ❑X Addressable ❑X Conventional 5.2.4 Sprinkler Waterflow Detectors Number of heat detectors: I ❑ Nonrequired partial area E] N/A Coded ❑ Transmitter ❑ N/A Number of waterflow detectors: Not Retail Type of devices: QX Addressable F Conventional [:] Coded Specific Transmitter F N/A 5.2.5 Alarm Verification Number of devices subject to alarm verification: none Alarm verification on this system is: F Enabled ❑X Disabled F] Set for seconds Record of Completion form (based on NFPA 72 — 2007) NFPA 72, 2 of 5 NFPA Unit 101.doc 6/1/201011:34:00 AM R.W. Evans Reprinted with pernission from NFAP 72 -2007, National Fire Alarm Code ®, Copyright 0 2007, National Fire Protection Association, Quincy, MA, 02269 6. SUPERVISORY SIGNAL- INITIATING DEVICES AND CIRCUITS 6.1 Sprinkler System Number of valve supervisory switches: 1 Type of devices: FX Addressable F� Conventional F Coded F Transmitter N/A 6.2 Fire Pump - See Detail for Main Bldg - SOLARIS Type of fire pump: F Electric F Diesel Type of fire pump supervisory devices: n Addressable ❑ Conventional F Coded F_� Transmitter F N/A Fire Pump Functions Supervised Fire pump power E] Fire pump running [—] Fire pump phase reversal ❑ Selector switch not in auto Engine or control panel trouble F Low fuel 701= 6.3 Engine- Driven Generator - See Detail for Main Bldg - SOLARIS Type of generator supervisory devices: F Addressable 0 Conventional F Coded F Transmitter EI N/A Engine or control panel trouble F Generator running F� Selector switch not in auto 0 Low fuel Other: 7. ANNUNCIATORS 7.1 Annunciator 1 Type: F Addressable 7.2 Annunciator 2 Type: F Addressable 7.3 Annunciator 3 Type: F Addressable Local Directory F] Graphic Local Directory F Graphic Local Directory F� Graphic FI Remote N/A Location: El Remote N/A Location: E] Remote 0 N/A Location: 8. ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1 Emergency Voice Alarm Service - CURRENTLY DISABLED AT TOV REQUEST - WHOOP ONLY Number of single voice alarm channels: 1 Number of multiple voice alarm channels: NONE Number of speakers: 4 Number of speaker zones: 1 8.2 Telephone Jacks Number of telephone jacks installed: N/A Number of telephone handsets stored on site Type of telephone system installed: Electrically powered ❑ Sound powered ❑X N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system (see NFPA 72, Table 6 S): Quantity: 0 Style: 0 Class: 0 Record of Completion forth (based on NFPA 72 — 2007) NFPA 72, 3 of 5 Reprinted with permission from NFAP 72 -2007, National Fire Alarm Code ®, Copyright © 2007, National Fire Protection Association, Quincy, MA, 02269 LT /A NFPA Unit 101.doc 6/1/2010 11:34:00 AM R.W. Evans 8. ALARM NOTIFICATION DEVICES AND CIRCUITS (continued) 8.4 Types and Quantities of Nonvoice Notification Appliances Installed Bells: With visual device: Horns: With visual device: Chimes: With visual device: Speakers: 5 With visual 5 device: Visual devices without audible devices: 2 Other (describe): 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED Hold -open door releasing devices Smoke management or smoke control ❑ Door unlocking — UPON C/O Elevator recall Other 10. SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage: 277/480 volt 3 phase 4 wire Amps: 2 services @ 4000 amps Overcurrent protection: Type: Fused Switches Amps: 2 services @ 4000 amps Location (of primary supply panel board): Garage Level South East corner of building Disconnecting means location: Fused Switches Switchbord MSB has 5 main switches MSA has 1 Main switch 10.2 Secondary Power Location: FCC Type: BATT Nominal voltage: Number of standby batteries: 2 Amp hour rating: _ Location of emergency generator: GARAGE Location of fuel storage: GARAGE Calculated capacity of secondary power to drive the system In standby mode: 24 HRS 11. RECORD OF SYSTEM INSTALLATION 12V Current rating: N/A 55 AH Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operation acceptance tests. The system has been installed in accordance with the following NFPA standards (Note any or all that apply): ❑X NFPA 72 FX NFPA 70, National Electrical Code, Article 760 F X Manufacturer's published instructions F — ] Other (please specify): System deviations from referenced NFPA standards: Signed: Printed Name: Date: Organization: Title: Phone: In alarm mode: 5 MIN Record of Completion form (based on NFPA 72 — 2007) NFPA 72, 4 of 5 NFPA Unit 101.doc 6/1201011:34:00 AM R.W. Evans Reprinted with permission from NFAP 72 -2007, National Fire Alarrn Code ®, Copyright © 2007, National Fire Protection Association, Quincy, MA, 02269 12. RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of: [X NFPA 72 FX NFPA 70, National Electrical Code, Article 760 rX Manufacturer's published instructions FX Other (please specify): RATIONAL ANALYSIS 0 Documen - dance with Inspection and Testing Form (Figure 10.6.2.3) is attached Signed Printed Name: Kenneth Ball Date: 8/12/10 Organization: Johnson Controls, Inc Title: LSS Phone: 303.328.5287 13. CERTIFICATIONS AND APPROVALS 13.1 System Installation Contractor The system as specified herein has been installed and tested in according to all NFPA standards cited herein. Signed: Printed Name: 1 \4104 Alf-L ��l Date: $ /2 c, JOO Organization: /41G4 oloi Title: \hejL LarcS,t 0Wj' Phone: —X378$ 13.2 System Service Contractor The system as specified herein has been installed and tested in according to all NFPA standards cited herein. Sig Printed Name: Ken Ball Date: 8/12/10 Or fzation: Johnson Controls, Inc Title: LSS Phone: 303.328.5287 13.3 Central Station The system as spe ' herein will be monitored according to all NFPA standards cited herein. Sign ; Printed Name: Ken Ball Date: 8/12/10 Organization: JCI — REMOTE OPERATIONS Title: LSS Phone: 800.753.4524 13.4 Property Representative I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed Name: If l Cfg A&:L00 i'1F /E � Date: T Organization: /tTitle: Phone: c ?O - 390. 3P Y? 13.5 Authority Having Jurisdiction I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, its approved sequence of operations and with all NFPA standards cited herein. Signed: Printed Name: Date: Organization: Title: Phone: Record of Completion form (based on NFPA 72 — 2007) NFPA 72, 5 of 5 NFPA Unit 101.doc &1/201011:34:00 AM R.W. Evans Reprinted with permission from NFAP 72 -2007, National Fire Alarm Code ®, Copyright © 2007, National Fire Protection Association, Quincy, MA, 02269