HomeMy WebLinkAboutA10-0044 Fire Alarm System Record of Completion Solaris Unit 206b- S FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY INFORMATION Name of property: SOLARIS — Retail Unit 206 Address: 141 EAST MEADOW DRIVE, VAIL CO Description of Retail Space property: Occupancy type: Name of property representative: Address: Phone: 970.790.6411 Fax: Authority having jurisdiction over this property: Phone: 970.479.2135 Fax: E -mail: MMCGEE ,VAIL.GOV 2. FIRE ALARM SYSTEM INSTALLATION, SERVICE, AND TESTING INFORMATION Installation contractor for this equipment: LEI COMPANIES Address: LEI — 2017 CURTIS STREE3T, DENVER, CO 80205 Phone: 303.934.5631 Fax: E -mail: LEI @LEICOMPANIES.COM Service organization for this equipment: JOHNSON CONTROLS, INC. Address: 10289 WEST CENTENNIAL ROAD, LITTLETON, CO 80127 Phone: 303.973.5930 Fax: 303.979.6847 E -mail: KENNETH.D.BALL@,JCI.COM Location of as -built drawings: Location of historical test reports: FIRE COMMAND FIRE COMMAND Location of system operation and maintenance manuals: FIRE COMMAND A contract for test and inspection in accordance with NFPA standards is in effect as of Phone: 1.800.753.4524 Contracted testing company: Johnson Controls Address: 10289 West Centennial Road, Littleton, CO 80127 Phone: 303.973.5930 Fax: 303.979.6847 E -mail: Occupancy type: M Contract expires: N/A Contract number: N/A Frequency of routine inspections: N/A 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter Reference of System Type: CHAPTER 6 Name of organization receiving alarm signals with phone numbers (if applicable): Alarm: REMOTE OPERATIONS CENTER - JCI Supervisory: I� SOLARIS PROPERTY OWNER - SPO REMOTE OPERATIONS CENTER - JCI Trouble: REMOTE OPERATIONS CENTER - JCI Phone: 1.800.753.4524 Entity to which alarms are retransmitted: VAIL FIRE DEPARTMENT DISP Phone: 970,479,2246 Method of retransmission of alarms to that organization or location: Phone Centeral Station Dispatch Record of Completion form (based on NFPA 72 — 2007) NFPA 72, 1 of 5 Reprinted with permission from NFAP 72 -2007, National Fire Alarm Code ®, Copyright ® 2007, National Fire Protection Association, Quincy, MA, 02269 VAIL FIRE DEPARTMENT E -mail: Jason .hasenberg(a),solarisvail.com 6/30/10 Phone: 1.800.753.4524 NFPA206.doc &24/20108:45:00 AM R.W. Evans P.- L 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE (continued) If Chapter 8, note the means of transmission from protected premises to the central station: ❑ X Digital alarm communicator McCulloh Multiplex 2 -way radio 1 -way radio If Chapter 9, note type of connection: Local energy Shunt OX N/A 3.1 System Software Operating system (executive) software revision level: Site - specific software revision date: 5.5 4. SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to this system (see NFPA 72, Table 6.6.1): Quantity: 1 Style: 4 Class: B 5. ALARM INITIATING DEVICE CIRCUITS Characteristics of initiating device circuits connected to this system (see NFPA 72, Table 6.5): Quantity: 0 Style: Class: 5.1 Manual Initiating Devices 5.1.1 Manual Pull Stations Type of devices: FX Addressable F Conventional 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Type of coverage: ❑X Complete area Type of devices: ❑X Addressable Type of smoke detector sensing technology Revision completed by: JIM MOREN Number of Manual pull stations: 1 Coded D Transmitter Number of smoke detectors: 4 Partial area Nonrequired partial area Conventional Coded Transmitter Ionization Photoelectric 5.2.2 Duct Smoke Detectors Type of coverage: Type of devices: F — ] Addressable Conventional Type of smoke detector sensing technology 5.2.3 Heat Detectors Type of coverage: F Complete area ❑X Partial area Type of devices: OX Addressable F7 Conventional 5.2.4 Sprinkler Waterflow Detectors Type of devices: [_-] Addressable 5.2.5 Alarm Verification Alarm verification on this system is: Number of duct smoke detectors: 0 ❑ Coded E Transmitter N/A ❑ Ionization ❑ Photoelectric Number of heat detectors: 2 Nonrequired partial area [_1 Coded ❑ Transmitter Number of waterflow detectors: 0 Conventional F] Coded F Transmitter Number of devices subject to alarm verification: Enabled IX Disabled Set for Record of Completion form (based on NFPA 72 — 2007) NFPA 72, 2 of 5 Reprinted with permission from NFAP 72 -2007, National Fire Alarm Code ®, Copyright 0 2007, National Fire Protection Association, Quincy, MA, 02269 12.0 0 N/A E N/A N/A N/A N/A N/A ❑ N/A seconds NFPA206.doc 8/242010 8:45:00 AM R.W. Evans 13. CERTIFICATIONS AND APPROVALS 13.1 System Installation Contractor The system as specified herein has been installed and tested in according to all NFPA standards cited herein. Signed: % hi-� Printed Name: %� . / �/ Date: Organization: �� �n,G'�i Title: Phone: 13.2 System Service Contractor The system as sg=4&4hexein has been installed and tested in according to all NFPA standards cited herein. Signed: Printed Name: Ken Ball Date: Organization: Johnson Controls, Inc Title: LSS Phone: 13.3 Central Station The system as s , e�ci�fied dh herein will be monitored according to all NFPA standards cited herein. Signed Printed Name: Ken Ball Organization: JC1— REMOTE OPERATIONS Title: LSS 7/7/10 303.328.5287 Date: 7/7/ 10 Phone: 800.753.4524 13.4 Property Representative I accept this systges as having be installed and tested to its specifications and all NFPA standards cited herein. Signed r Printed Name: Date: Organization: (� e , . , t � a s; L�LTitle: lii�"_ ��— Phone: _ 13.5 Authority Having Jurisdiction I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, its approved sequence of operations and with all NFPA standards cited herein. Signed: - �`'' Printed Name: f�0/c- Date: Organization: '����� Title: d ✓ Phone: 7 i _z - �C, ) cl Record of Completion form (based on NFPA 72 — 2007) NFPA 72, 5 of 5 NFPA205.doc 8124/20108:45:00 AM R.W. Evans Reprinted with permission from NFAP 72 -2007, National Fire Alarm Code a, Copyright 0 2007, National Fire Protection Association, Quincy, MA, 02269 8.4 Types and Quantities of Nonvoice Notification Appliances Installed Bells: With visual device: Horns: With visual device: _ Chimes: With visual device: Speakers: 3 With visual 3 device: Visual devices without audible devices: 1 Other (describe): \ 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED Hold -open door releasing devices F - ] Smoke management or smoke control Door unlocking 7 Elevator recall F Other 10. SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage: 277/480 volt 3 phase 4 wire Amps: 2 services @ 4000 amps Overcurrent protection: Type: Fused Switches Amps: 2 services P, 4000 amps Location (of primary supply panel board): Garage Level South East corner of building Disconnecting means location: Fused Switches Switchbord MSB has 5 main switches MSA has 1 Main switch 10.2 Secondary Power Location: FCC Type: BATT Nominal voltage: 12V Current rating: N/A 55 AH Number of standby batteries: 2 Amp hour rating: Location of emergency generator: GARAGE Location of fuel storage: GARAGE Calculated capacity of secondary power to drive the system In standby mode: 24 HRS 11. RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operation acceptance tests. The system has been installed in accordance with the following NFPA standards (Note any or all that apply): FX NFPA 72 ❑X NFPA 70, National Electrical Code, Article 760 7 X Manufacturer's published instructions 0 Other (please specify): System deviations from referenced NFPA standards: Signed: Printed Name: Date: Organization: Title: Phone: 12. RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of- 0 NFPA 72 a NFPA 70, National Electrical Code, Article 760 ❑X Manufacturer's published instructions 0 Other (please specify): RATIONAL ANAL YSIS El Documentation ' accordance with Inspection and Testing Form (Figure 10.6.2.3) is attached Signed - -_ Printed Name: Kenneth Ball Organization: Johnson Controls, Inc Title: LSS In alarm mode: 5 MIN Date: 7/7/10 Phone: 303.328.5287 Record of Completion form (based on NFPA 72 — 2007) NFPA 72, 4 of 5 NFPA206.doc 8/24/2010 8:45 :00 AM R.W. Evans Reprinted with permission from NFAP 72 -2007, National Fire Alarm Code e, Copyright 0 2007, National Fire Protection Association, Quincy, MA, 02269