Loading...
HomeMy WebLinkAboutB11-0477NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Mop via. . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: 611 -0477 Project #: PRJ11 -0683 Job Address: 2189 CHAMONIX LN VAIL Applied.....: 11/08/2011 Location......: BOILER FOR GORE RANGE CONDO II Issued...: 11/09/2011 Parcel No....: 210311405001 OWNER WESTRA FAMILY TRUST 11/08/2011 13727 W AMHURST WAY LAKEWOOD CO 80228 APPLICANT BURCH PLUMBING AND HEATING 11/08/2011 Phone: 970 - 376 -3191 PO BOX 9555 AVON CO 81620 License: C000003397 CONTRACTOR BURCH PLUMBING AND HEATING 11/08/2011 Phone: 970 - 376 -3191 PO BOX 9555 AVON CO 81620 License: C000003397 Description: ISOMMON ELEMENT: RERU4CE FAILED BOILER;tLLOCATED IN THE STORAGE LAUNDRY ROOM. Occupancy: R -2 Type Construction: V Valuation: $21,000.00 FEE SUMMARY ************************************************ * * ** *** *** *** * * * *** * * * *** * * * *** Building Permit ------ - - - - -> $335.25 Bldg Plan Check ---- - - - - -> $217.91 Use Tax Fee ---------------- - - - --- > $220.00 Electrical Permit -- - - - - -> $0.00 Elec Plan Check - - - - - -- > $0.00 Restuarant Plan Review - - -- $0.00 Mechanical Permit - - - - -> $420.00 Mech Plan Check --- - - - - -> $105.00 Additional Fees------- - - - - -- ($553.16) Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check --- - - - - -> $0.00 Recreation Fee ----------------- - -> $0.00 Investigation --------- — ------------ > $0.00 Will Call --------- ---- -------- - - - -> $5.00 TOTAL PERMIT FEES - -- - -> $750.00 Payments ---- ----- -------------- — ------ > $750.00 BALANCE DUE --- ---------- -- --------- > $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. Signature of Owner or Contractor Date Print Name combination permit_012811 li�ll�l1 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0477 Owner: WESTRA FAMILY TRUST BOILER FOR GORE RANGE CONDO II Address: 2189 CHAMONIX LN VAIL Location: combination permit-012811 TOWN OF VAILL; 7 REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0477 Owner: WESTRA FAMILY TRUST BOILER FOR GORE RANGE CONDO II Address: 2189 CHAMONIX LN VAIL Location: Item: 00390 MECH -Final combination permit-012811 a 11 -17 -2011 Inspection Request Reporting Page 14 4:55 pm Vail, CO - Cityof Requested : Date: Friday, November 18 2011 Site Address: 2189 CHAMONIX LN VAIL BOILER FOR GORE RANGE CONDO II A/P /D Information Activity: B11 -0477 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: R -2 Insp Area: Owner: WESTRA FAMILY TRUST Contractor: BURCH PLUMBING AND HEATING Phone: 970 - 376 -3191 Description: COMMON ELEMENT: REPLACE FAILED BOILER. LOCATED IN THE STORAGE LAUNDRY ROOM. Reauested Inspections Item: 390 MECH -Final Requestor: Rachelle Assigned To: JMONDRAGON Action: Time Exp: Inspection History Item: 390 MECH -Final W4_ Requested Time: 08:00 AM Phone: Entered By: LCAMPBELL K REPT131 Run Id: 13784 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Tom OF Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0477 Project #: Job Address: 2189 ST MORITZ LN VAIL Location......: GORE RANGE CONDO II Parcel No....: 210311405001 OWNER WESTRA, ROGER & MARIAN 11/08/2011 13727 W AMHURST WAY LAKEWOOD CO 80228 APPLICANT BURCH PLUMBING AND HEATING 11/08/2011 Phone: 970 - 376 -3191 PO BOX 9555 AVON CO 81620 License: C000003397 CONTRACTOR BURCH PLUMBING AND HEATING PO BOX 9555 AVON CO 81620 License: C000003397 11/08/2011 Phone: 970-376-3191 Description: COMMON ELEMENT: REPLACE FAILED BOILER. LOCATED IN THE STORAGE LAUNDRY ROOM. Occupancy: R -2 Type Construction: V Applied.....: Issued... PRJ11 -0683 11/08/2011 11/09/2011 Ak - ,�_OS , �Vzq/n 1� C �JANh 1 �z1 - ' ►400xz! Z MA (ur j Valuation: $21,000.00 «.... xxxxxxxxxxxxxxxx« xx« xx« xx« xxxxx« x xxxxxxxxxxx ............... « «x «xx «« FEE SUMMARY '""'""*"""' xx x«« xxxx«« xxx« xxxx xxxxxxxxxxxxxxx« x «xxxxxxxxxxxxx «xxx «xxxxxxx.x «. Building Permit ------ - - - - -> $335.25 Bldg Plan Check ----- - - - - -> $217.91 Use Tax Fee ---------------- — ----- > $220.00 Electrical Permit -- - - - - -> $0.00 Elec Plan Check ------ - - - - -> $0.00 Restuarant Plan Review -- ----- > $0.00 Mechanical Permit - - - -> $420.00 Mech Plan Check ---- - - - - -> $105.00 Additional Fees--------------- - - - - -> ($553.16) Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation ----------------- $0.00 Will Call ------ -- ----------- - - -> $5.00 TOTAL PERMIT FEES -- --- -> $750.00 Payments -- --------- -- ---- ---- --------- > $750.00 .« xxxrxx.x rtxxxxxxxxxxxxx, rxxre. xwr.. r.. x. xx. x. xxxwxxx: wxws. xxxx, r, rxxwx, ewrwwxxxrw., re. rr. xwx. xr., vx+ xxxxxxxxxxxxxxxxxrexxxw. BALANCE DUE --------- — ------- - -> v.... xx. xxx. xxxx... xxxxxxxxxxxwexxxxxrrx ,ewexw,rxr.wx•rr.r.w..x.xrr.. $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FP5 INSP CTIO SHALL BE ADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4: M. ignature of Owner or Contractor Date &�e_i1e_ r d Print Name combination permit_012811 m wfwxRRfirR} Yr www## wxxwrrrrrr# ww# ww## ffftrt# ffrRerx* r*** wfwf## fi# f# RfffrrRR*** rrwwww# fxxffff* fRrYk**** fwwwwffrfr#:* fff* Rfntw} tYe** wwx## RfrfifxxRRRRRRw* w} tw# ffww# A4ff ►ff*Y*RRrfr}r►*RtrM *rrf4 /it* CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0477 Address: 2189 ST MORITZ LN VAIL Owner: WESTRA, ROGER & MARIAN -JT Location: GORE RANGE CONDO II YYRYRRwRRR* rrY## RkkRR# firxw** rt******* xYwxwxRRxfifffrr* RrRr* R* f# x* xwfffffR* fffHRRRR*** R41�R* f�R**t f# w## xffffiR* rrrrw**** w*w* R*Vrwfffffr*Rrrfr*R * * * * #www #f #w RfxffiRRRRRRRRRfrM1�r *RRfr4Ur�tr*ff combination permit_012811 TOWN OF VAIL V REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0477 Address: 2189 ST MORITZ LN VAIL Owner: WESTRA, ROGER & MARIAN -JT Location: GORE RANGE CONDO II Item: 00390 MECH -Final combination permit_012811 BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 2-1$ Ck oumoni X L_N (Number) (Street) (� (� (Suite #) Building /Complex Name: Contractor Information I 1 Business Name: v r Business Address: PC City Av.Q ayl —r— State: Zip: O r OZ O Contact Name: t ' Y r Contact Phone: f - 70 :?> - 7 (O " 3 1 Contact E -Mail: 1 M(otJ t2i tit v c-Vi n 10 M bi Contractor Registration Number: �— X k Owner/Ow6er's Representative Signature (Required) Info Owner r Nam rmatio e: ' O � Owr Nam L�1 ' l .1103 114 05 001 -2-10 2 I l 4-O oa Parcel #: (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8840 or visit www.eaglecounty.us/patie) DRB #: — AIA " MIy Building Permit #: q L Lot #: _J_ Block # Subdivision: VALL E[ (iHT5 Work Class: New ( ) Addition ( ) Alteration ( A Type of Building: Single- Family ( ) Duplex( ) Multi - Family 00 Commercial( ) Other( ) Work Type: Interior ()6 Exterior ( ) Both ( ) Valuation of W ork Inc Plans Included Work Electrical ( *Yes (NNo ( )Yes ( )No Mechanical O)Yes ( )No X)Yes ( )No 71(Y - Plumbing ( )Yes K)No ( )Yes ( )No Building ( )Yes X)No ( )Yes ( )No Value of all work being performed: $ (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage Detailed Scope and Location of Work V Qlci ce o; , e v -t Ind \A a S Tcti e Ck (use additional sheet if necessary) For Office Use Only: _ Fee Paid: Received From: o -Q LLL Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Date Receiv F. D z NOV o 12011 ril W TOWN OF VAIL 01 -Jan -11 Department of Community Development 75 South Frontage Road Vail, Colorado .81657, TO: 970- 479 -211 k Web www.vailgov.com Development Review Coordinator' State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two - Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single - family dwelling: any dwelling unit that is used primarily for a single family, including multi - family /condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State - certified abatement contractor. The clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: Will not disturb more than the threshold limits identified above. Tested negative, or at 1% or below (1 copies of test results included) ❑ Tested positive at more than 1 %, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos - containing materials, so buildings of aM age require testing. • The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos - containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. 1 Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire 970 - 479 -2252 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303 - 692 -3158 asbestos @state.co.us www.cdphe.state.co.us 0 O1- Jan -11 Department of Community Development ,;, 75 South Frontage Road 'i Vail Colorado 81657 Tel: 970 - 479 - 2128 �. , Web: www.vailgov:com - Development Review Coordinator .. S '_ • � '4+' - "A BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 11 $9 Ck ot-m n; X LN f Project #: PR u ^ 0lD 3 / / (Number) (Street) (Suite #) , . DRB #: - Nf} (� Building /Complex Name: �Of ar ' ` C O !y Building Permit #: q 1 Lot #: J_ Block # Subdivision: VA I L 9fiI61115 Contractor Information _ __._.. _..___.. _. -_. _ -.__----------- - -- Work Class: New ( ) Addition ( ) Alteration Business Name: V W�bi �tea�� Business Address: Fb Box °( 5 5 s Type of Building: City A oy State: CC Zip: O I fOZ0 Single - Family ( ) Duplex ( ) Multi - Family (x) Contact Name: l r YVI t?>U r On Commercial ( ) Other( ) Work Type: Interior (� Exterior( ) Both( ) Contact Phone - 70 :3> - 7 I'O" 3 1 9 1 n Contact E -Mail: rVO b LA ✓ ck p l V VVt bi a L_D Valuation of I J Work Included Plans Included Work Contractor Registration Number: �— Electrical ( *Yes (,K)No ( )Yes ( )No X Mechanical O)Yes ( )No X)Yes ( )No Z/ (Toy . Plumbing ( )Yes K)No ( )Yes ( )No Building ( )Yes X)No ( )Yes ( )No Owner /Ow er's Representative Signature (Required) Project Informatiorti/ 1 -r Owner Name: L�lC� Qo 1 _I I o3 11 05 001 -2 162 1 t 4-p om Value of all work being performed: $ V. ODO. Parcel #: c (value based on IBC Section 109.3 & IRC Section 108.3) (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.uslpatie) Electrical Square Footage Detailed Scope and Location of Work V_c PkQ cc b o; k e - t - "0:� - �A a S � �e d CL . -Y V/0OVVI (use additional sheet if necessary) For Office Use Only: 0S - , Date Receiv I�11 �/7 E C Fee Paid: �JD L \V D Received From: o-g L LL Cash Check # Nov o 1 2011 CC: Visa / MC Last 4 CC # exp date: Auth # TOWN OF VVAIL 01 -Jan-11 State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two - Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single - family dwelling: any dwelling unit that is used primarily for a single family, including multi - family /condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State - certified abatement contractor. The clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: Will not disturb more than the threshold limits identified above. F Tested negative, or at 1% or below (1 copies of test results included) ❑ Tested positive at more than 1 %, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos - containing materials, so buildings of aM age require testing. • The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos - containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire—inspectors@vailgov.com 970 - 479 -2252 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303 - 692 -3158 asbestos @state.co.us www.cdphe.state.co.us 01- Jan -1 I G� Oy- G ' R , Y\ °` Jo - LF a Y\ + x \16�, I L Town REVI COM Date: By: Code; 2 Ao t— CD c y� 3� o� u Nov o 12011 Q TOWN OF �'V Typical Piping To Existing Baseboard Zones ' /A" Copper Supply & Returns F-1 a� �s> 1 -1/2" Pipe Size E AS -1 (D N U) (D _d D_ PP = 1 PP = 2 a� Q m N T U) 1 -1/2" Pipe Size N OV Of �if N PLEA OR COD D, E Ce Stub outs for future Indirect Hot Water Heater. 1 - '/ " Pipe Size Z­4-114" Pressure Bypass Valve &Loop AdEMW V�� ls� D n NOV 0 12011 Note: This drawing is for illustrative purposes only. Prepared for: Burch Plumbing & Heating FE Not all required components are shown. Local codes, Reference: Gore Condo Boiler Replacement regulations, and authorities have final jurisdiction, Date Date: 10/25/1 1 Prepared By: Andy Casper 4 r V�� ls� D n NOV 0 12011 Note: This drawing is for illustrative purposes only. Prepared for: Burch Plumbing & Heating FE Not all required components are shown. Local codes, Reference: Gore Condo Boiler Replacement regulations, and authorities have final jurisdiction, Date Date: 10/25/1 1 Prepared By: Andy Casper 4 B�ilei' S�fl�t'lU /C , � <Pump ttlfe Heat Supply Fuel Fluid input Mod. Output Mori. Ar Water Vent: Air S &R P -11 Tag Mfg Mode/ Type Type (BTUH) Site Elev. (BTUH) Vol. (gal.) Size (in) Conn. (in.) Notes B-1 Tnang!e Tula Pres ige Solo 253= NG _ GlycaS 55 000 - 245,9:-3 43,048 - 185,416 41 3 `: -1f4 t, 2 1 ") Site Elevation estimated at 6,C -00 Y 2) Instal) %vtfi AA>m NC1 condensate neu raltation kit 1 -) Ptmnp set to speed: a Love b. Medium c. High d. AutoAdapt '�'� �t~ `-• rye- s� �,; � �;; a w � s vvaly` • a o ALE ► et Vail REVIEWED FOR CODE COIVIPLIAIV E Date: a 3y: Code: —o.Q LEGEND � <Pump ttlfe Heat Supply - Primary/Secondary, Purge Tee Tag Mfg. Model Service GPM FT Head Max HP Volt , Pltase Max Anil Fluid Type p Notes P -11 Grunrtfos r UPS26 -�rC Boiler � 18.E 5 1r6 11 � 1.8 3TI. Gycol 1I3, 2a P - 2 Grundfea LlPS26 Baseboard Zor�es 18.2 4 11E 115 1 1.8 39 Gycol 1 b , in 1 -) Ptmnp set to speed: a Love b. Medium c. High d. AutoAdapt '�'� �t~ `-• rye- s� �,; � �;; a w � s vvaly` • a o ALE ► et Vail REVIEWED FOR CODE COIVIPLIAIV E Date: a 3y: Code: —o.Q LEGEND L This drawing is for illustrative purposes only. Prepared for: Burch Plumbing & Heating FERGUSON' equired components are shown. Local codes, Reference. Gore Condo Boiler Replacement �� ��� /1105 tions, and authorities have final jurisdiction. Date: 05/26/11 Prepared By: Andy Casper 2.) Pump constructe-d of a. Cast Iron b. Bronze c_ Stainless Steel Tank Max Accept. Height Dia. System Max Working Max Operating Tag Mfg, Model Volume (gal.) Volume (gal.) (in.) (in.) Conn. (in.) Pressure Temp ET -1 Arnim £G 3.6 2.5 F 2 _ 3 ___ T ___ 11 112 hAINPT 1-5: osir ?4n* F Heat Supply - Primary/Secondary, Purge Tee f\�,J Spring Check Valve Air Separator �� Heat Return Pressure Bypass Valve Zone Valve Expansion Tank - - - - - - - Domestic Hot Supply - - - - - - - - Domestic Cold Supply Boiler Drain Circ. w/ Flow Check & Iso Fig Ball Valve 4WO —� Boiler Autofill & Backflow L This drawing is for illustrative purposes only. Prepared for: Burch Plumbing & Heating FERGUSON' equired components are shown. Local codes, Reference. Gore Condo Boiler Replacement �� ��� /1105 tions, and authorities have final jurisdiction. Date: 05/26/11 Prepared By: Andy Casper 2.) Pump constructe-d of a. Cast Iron b. Bronze c_ Stainless Steel Tank Max Accept. Height Dia. System Max Working Max Operating Tag Mfg, Model Volume (gal.) Volume (gal.) (in.) (in.) Conn. (in.) Pressure Temp ET -1 Arnim £G 3.6 2.5 F 2 _ 3 ___ T ___ 11 112 hAINPT 1-5: osir ?4n* F V MECHANICAL SPECIFICATIONS JOB: GORE CONDO BOILER REPLACMENT JOB NUMBER: 11068.00 BY: BJ H DATE: 10/31/11 General 1. Immediately notify the engineer of any discrepancies. d �,. ��:� • •t ra cop -r �s:ti 1 P s a a - rs 2. It is the intent of these drawings and specifications to establish a standard of quality. The engineer reserves the right to take exceptions to approve methods and materials not reflected herein. 3. Work shall be performed in a workmanlike manner to the satisfaction of the owner & the engineer. 4. Labor, materials, and equipment shall conform to the latest applicable editions of local, State of Colorado, and National Codes and ordinances. If conflict between those publications exists, the most stringent requirement shall apply. 5. The drawings show the intent of the mechanical systems but do not show all details required. It is the responsibility of the contractors to install complete & operable systems, which conform to the manufacturers' installations instructions & industry standards. 6. Systems shall be tested for proper operation. If tests show work is defective, contractor shall make corrections necessary at no cost to owner. 7. It is the contractors' and manufacturers' responsibility to assure themselves that the code authorities will approve any product to be installed on the project. 8. Contractor must carefully verify electrical service voltage and phase available before ordering any equipment. Insulation 9. Insulate all new heating water, domestic hot water, and domestic hot water recirculation with U.L. approved, white, all service, glass fiber, snap -on, pipe insulation. 1 -1/2" thick on piping <_1.5" in diameter and 2" thick on piping >1.5 ". Insulate fittings with glass fiber blanket insulation and premolded PVC covers. Provide deduct alternate price to insulate with Armaflex closed cell foam insulation. 10. Insulation for all types of piping shall be carried full size through pipe hangers or pipes shall be supported with vibration clamps. Pipin 11. Domestic Hot, Cold & Recirculation piping inside building - Type 'L' copper water tube, wrought copper fittings and no lead solder. 12. Heating Water piping - Type 'L' copper, wrought copper fittings, and no lead solder. 13. Gas Piping - Schedule 40 black steel pipe, 150 lb. malleable iron screwed fittings on above ground pipe, welded fittings with all piping coated and wrapped on buried pipe. CSST pipe is prohibited. 14. Gas Valves - Lubricated plug valve 175 lb. W.O.G. iron screwed or flanged. 15. Copper pipe Valves and Specialties: a. Gate Valves: Bronze, Class 125, 200 lb. W.O.G. b. Ball Valves: Bronze, Class 125, 200 lb. W.O.G. c. Check Valves: Bronze, Class 125, 200 lb. W.O.G. d. Balancing Valves: 125 psig w.p. for 250F service tight shut -off, Illinois dual - purpose, balancing /shut -off valve, Hoffman, Sarco, or equivalent. 16. Dielectric Unions - Furnish and install a dielectric union at all connections where non - ferrous material is in contact with ferrous material and fluid in not protected with corrosion inhibitors. 17. Grade and valve all heating water piping with 3 / " hose end valves to permit drainage of the system. Vent all high points in equipment rooms as necessary with automatic air vents piped to convenient drain. All high points in system outside of equipment rooms with manual air vents as required to relieve air in the system. Antifreeze Solutions 18. Fill heating water system with minimum 30% propylene glycol / 70% water solution, by volume, for freeze protection to 8 °F and burst protection to -20T. Include corrosion inhibitors. Boiler Specifics 19. Condensing Boiler Condensate shall be neutralized via a neutralization basin before discharge into building drainage system. Condensate piping shall be PVC or other approved material suitable for pH levels of 3. 20. Boiler flue pipe shall be CPVC (not PVC) due to high temperature application of boiler (baseboard heating and domestic hot water heating). Install per manufacturer's installation instructions. 21. Boiler combustion air pipe can be PVC. Install per manufacturer's installation instructions.