HomeMy WebLinkAboutB11-0493NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
.__�
.�
�row���veii. �
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970,479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B11-0493
Job Address: 200 VAIL RD VAIL
Location......: LODGE TOWER MECHANICAL ROOM
Parcel No....: 210108224000
OWNER LODGE TOWER HOA
200 VAIL ROAD
VAIL
CO 81657
APPLICANT R& H MECHANICAL LLC
DAVID YOUNG
825 CHAMBERS AVE / PO BOX 81�
EAGLE
CO 81631
License C000003182
CONTRACTOR R 8 H MECHANICAL LLC
DAVID YOUNG
825 CHAMBERS AVE / PO BOX 81
EAGLE
CO 81631
license: C000003182
11/17/2011
11/17/2011 Phone:970-238-2699
11l17/2011 Phone:970-238-2699
Description:
REMOVE TWO OLD BOILERS AND REPLACE WITH TWO PATTERSON KELLY
(LIKE KIND REPLACEMENT) TWO MILLION BTU BOILERS IN
MECHANICAL ROOM.
Occupancy: R-1 Type Cor�struction:
Project #:
Applied.....:
Issued. . . :
P RJ 11-0697
11l17/2011
11129I2011
Valuation: $81,400.00
................»,,.«.,.....,........»..,..».,,.....,,..........,,.,.,,«.......... FEE SUMMARY «.....„................,...........«..............,.«................,....,...
Building Permit -----------> $867.75 Bldg Plan Check ----------> $564.04 Use Tax Fee--------------°> $1,428.00
Electrical Permit -------> 50.00 Elec Plan Check --_______> $0.00 Restuarant Plan Review---> $0.00
Mechanical Permit ------> $1,640.00 Mech Plan Check --------> $410.00 Additional Fees----------> $�,431.79)
Plumbing Permit -------> $0.00 Pimb Plan Check -------> 50.00 Recreation Fee-----------------> $0.00
Investigation----------------------� 50.00
Will Call------------------------> $5.00
TOTAL PERMIT FEES-------------> 53,483.00
Payments------------ ----> 53,483.00
BALANCE DUE--------------------> 50.00
♦Waf�t4�tttltY'���"Yy�MW�t��F�y'aYft+"�'Mr��rW�y�tr�z�t+��ftwfffft�ytfh��aftwYY�f'�'rtt+'ttt��Ww�tMft'vY'WttR�wWV��i�it*t��tff�V�+Y'I/r�4�'���Y1Yffi}ffl��4fr�1rlrf����M'YM�lt�/A}f��#ttH'k4tttttYffft��•
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
RE(�UESTS FOR INSPECTION SHALL BE MADE TWE�TY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 870.479.2149 OR AT OUR OFFICE FROM
8:00 AM - 4:00 PM.
r `2 �
i�
Signature of Ow r Con ctor ate
`
Print Name
combination permit 012811
.
�
1 V�1'!� V� Y� ,
.....................................................................................,.................................,...................................,.,.........,,.,.,,......,.
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: 611-0493
Owner: LODGE TOWER HOA
LODGE TOWER MECHANICAL ROOM
Address: 200 VAIL RD VAIL
Location:
............................................................................x,.�.....................».........................,,,....,.......,.............,..,,.,.............,....
combination permit_012811
.
i
��� �� ��i�' .
*�***************.,***.,,.*************************************************.*,.**********************.,.,*******.,.,*.w„***„*********.**************,******
REQUIRED INSPECTIONS AND STATUSES
Permit #: 611-0493
Owner: LODGE TOWER HOA
LODGE TOWER MECHANICAL ROOM
Address: 200 VAIL RD VAIL
Location:
..*****..********�********„*�***.,************..*�****«*.,***„**************************�.**«***««******,,,.*****��****.*******«*,,.**«***„**„******.,**«**
Item: 00200 MECH-Rough
Item: 00240 PLMB-Gas Piping
Item: 00390 MECH-Final
Item: 00090 BLDG-Final
combination permit_012811
*******************************�******************�*******************+********«*********�**
TOWN OF VAIL, COLORADO Statement
********************************************************************************************
Statement Number: R110001715 Amount: $3,073.00 11/29/201109:08 AM
Payment Method:Credit Crd Init: LC
Notation: CREDIT CARD
FROM SCOTT YOUNG R&H MECHANCIAL
-----------------------------------------------------------------------------
Permit No: B11-0493 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-082-2400-0
Site Address: 200 VAIL RD VAIL
Location: LODGE TOWER MECHANICAL ROOM
Total Fees: $3,483.00
This Payment: 53,073.00 Total ALL Pmts: $3,483.00
Balance: $0.00
********************�*****************************+***********************+*****************
ACCOUNT ITEM LIST:
Account Code
--------------------
MP 00100003111100
UT 11000003106000
WC 00100003112800
Description Current Pmts
------------------------------ ------------
MECHANICAL PERMIT FEES 1,640.00
USE TAX 4% 1,428.00
WILL CALL INSPECTION FEE 5.00
-----------------------------------------------------------------------------
TOWN OF VAIL COM DEU
75 S fRONTR6E RD.
UAIL: CO 81657
979-419-2324
TERMINAL I�O.� 2802
MERCHRNT II;
UISA
�t�kti�utt�ukt1B98�
MAIL ORDER
BATCN; 988393 IWU:000003
AUTH:029547
NOV 29a 11 09:04
TOTAL �3073.00
CU3i0MER COPV
*********+******�******�***«***********��************************�***********************�**
TOWN OF VAIL, COLORADO Statement
*******�*«*************************************�******�*****�*********************«*********
Statement Number: R110001683 Amount: $410.00 11/17/201101:33 PM
Payment Method:Credit Crd Init: DR
Notation: MC BRENT
-----------------------------------------------------------------------------
Permit No: B11-0493 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-082-2400-0
Site Address: 200 VAIL RD VAIL
Location: LODGE TOWER MECHANICAL ROOM
Total Fees: $3,483.00
This Payment: $410.00 Total ALL Pmts: $410.00
Balance: $3,073.00
*************�*********�********************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 410.00
-----------------------------------------------------------------------------
��
TQWN OF VA(L �
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970-479-2128
www.vailgov.com
Development Review Coordinator
TRA�ISMITTAL FORM
Revision Submittais:
1. "Field SeY' of approved plans MUST accompany revisions.
2. No further inspections will be performed until the revisions are approved & the permit is re-issued.
3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance.
Permit #(s) information applies to: Attention: () Revisions
( ) Response to Correction Letter
�l — ��q � _attached copy of correction letter
( ) D ferred Submittal
( Other S /RMPE,p
Project Street Address:
� -� •�- � 1 �.� � �(�-�.�.,
y .:1, � a
(Number) (Street) (Suite #}
g P ��(� � Description / List of Changes:
Buildin ICom lex Name: d �1,�1�-�-�_
�Tf� M P� �QA W i n1 C.�.,S
Contractor Information
Business Name: � � � ,1"l,P���
� - - -
Business Address: �ZZ' C �
City �q cJ�-e state: C� zip: Ff�io 3 1
ContactName: Dce�� ��,�i� �SL�7� Io�N�-i:
TT (use additional sheet if necessary)
Contact Phone: � �'O Zi Z � 2-� � � ' ., ..._. . .,, ,._ ...:. , _._ _ ... . . .. _ . _ . ,
�—•
/� r Revised ADDITIONAL Valuations (Labor 8� Materials)
Contact E-Mail: ���� V�L ( A' r q�.l d� � p�t c��••� ��� •'(DO NOT include original valuation)
� ^n
X Building: $
Owner/Owner's Representative Signature (Required) Plumbing: $
Applicant Information
Applicant Name:
Applicant Phone:
Applicant E-Mail:
For Office Use Only:
Fee Paid:
Received From:
Cash Check # _
�, CC: Visa / MC Last 4 CC #
I Auth #
exp. date:
Electrical: $
Mechanical: $
Total:
Date Received:
$
i` a�',' ' ,� `��� �`�
�i ,_, ' �_� �� �:'� � f
I`
��
NOV 2 � `1011 U
TOWN OF VAIL
o�-o�t-i i
�o � �.�a��-
�: - `� . ,:: � ,, ���s�rtmec�t_�f �or�m�rc�it� D�weia��m��i
E' „� - ' _* � +F 7= _
,�. � �:� t• r _-:�� F5 South Froc�t��� E�aad.
i- - : ` _. N:` � - - � �a6E �a�iorad�. ���657�
I - ` t-.� � ;. _ - Tel:' �f0-47S-2'l28;:
I" • � . _ �R 'i f'r Y� � �� �.�;
. ". � . , , _ � `' r' .. - � �Jlfeb: wy��r:vailga�� cc�r�;;
� : � _' A` � �<: _=' �£ �,.,rV ._.:�.� � ="_ �� �e��elop d«�i:c►r-.
inent Review Caor
a ¢� E r ,
�^� � r �` ����S.L'ae�.��.. h' _ i•e ( •�� ��..�.t. �::3 f f 1 . '�4 �'+�'�
— _ I
����a��c�G ����E-� a����c��-�ar�
(Se�arate applications are required for alarm & sprinkler)
Fcoject St�eet ,4cid�ess: Project #: P R3 � I.� ��09 �
aob � D�.,✓4.
(tsuQnber) (Street) (Suite #) DRS #: — -
---- _ Bc�ildina/Complez harne: ! Q'�6�. 1 t��xy � Buiiding Permit #: �� �- p�9 3
� Lot #f��Block # �JC Subdivision: l%l1��c liio�LaC,
C��stra�toc!^fo.-^:at9�� Ft V1dC �
Busi�2ss Name: � t 1�i� ��I}I�l� L Work Class: New ( ) Addition ( ) Alteration ; }
Business Address: $2 ) �i: � 6�j �`�h1 �' ��
Type of Building:
C�Y � Z••� State:�_ Zip: �_ Single-Family () Quplex () P,Aulti-Family ()
g�j,�. 1. 1` �� Commercial �Q' Other O
Contact Name: Vvr
Contact Phone: 1� D 3?.�4 2 6'19 Work Type:
Contact E-Mail: ��Q�TI�Q i�hl�y( �yy��h������ ° `
nt;a tor Re ' tion (�umb � /VrT _
Electrical
Mechanical
O r/Owner's Repres2ntative Signature (Required) Plumbing
Project Informatioc� ���E T 416� guilding
OK+nec Name•
Interior (k) Exterior ( ) Both ( )
Valuation of
Work Included Plans Included 1A�ork
( )Yes ( )No ( )Yes ( )No
(k)Yes ( )No (,�jYes ( )No ��
)Yes ( )No ( )Yes ( )No
)Yes ( )No ( )Yes ( )No
ParceE #: Value of all work being performe�: $��
(For P�arcel #, contact Eagle County Assessors Office at (870-3 8-8640 or visit ��alue based on fBC Section 109.3 & IRC Section 108.3)
www.eaglecounty.uslpatie) ElecVical Square Footage
�40� o$a a�.000 :__
Deta.iled Scope and Location�f Work: �� '��1A{.,L ' /',�e�''� f�, jp�i �y _ �� � � �
.
�
(use additional sheet 'rf necessary)
� 2 rr•. I
For Offiee �Jse Q�fy:
IFee f�aid: _�`ilp.00
Received From: i�Qe.Nr F. W t S�
Cash Check #
CC: Visa �Last 4 CC # L 1 � exp date: Oa. 1�i
Auth # 10315/0
b3ate Recedved:
� C � � �J l—
���� �L� C; ��� �-;
i�;
,' �; � NOV 17 ZOlI
.. �
TOWN OF VAIL
ENCINEERED PRQD�ICT� Ct�MP1�I�Y
11099 W 8TH AVE., LAKEWOOD CO 80215
� Phone #303-777-4471 Fax #303-777-4476
DATE & TIME 11/17/2011 7 56
POSITIVE PRESSURE COMPUTER STACK CALCULATION
PLEASE SPECIFY SCHEBLER and/or FasNSeal
PREPARED BY: Dave Baumann
PREPARED FOR: Brent Wilson R and H Mechanical
NAME OF PROJECT: �od e Tower Vaii
EQUIPMENT INFORMATION: (3) P-K N-2000 - 2 Hi-�ow Boilers
INITIAL DATA
FUEL BURNED ?
NATURALGAS _ �
PORTION OF STACK USED IN THIS CALCULATION : COMPLETE
FEET ABOVE SEA LEVEL 8150
TOTAL INPUT OF HEATING APPLICANCE(S) MBH 6000
GROSS FLUE GAS TEMPERATURE-DEGREE F : 275
AMBIENT TEMPERATURE (OUTSIDE AIR)-DEGREE F. 70
HEIGHT OF STACK IN FEET 85
TOTAL FOOTAGE OF PIPE 105
NUMBER OF 15 DEGREE ELBOWS 0
NUMBER OF 30 DEGREE ELBOWS 0
NUMBER OF 45 DEGREE ELBOWS 4
NUMBER OF 90 DEGREE ELBOWS 1
NUMBER OF 90 DEGREE TEES : 2
NUMBER OF 45 DEGREE TEES : 3
NUMBER OF DRAIN SECTIONS 1
TYPE OF STACK TERMINATION? NOTE: When barometric damper is
STACK TERMINATION CAP � selected, calculation is based on 0" back
BAROMETRIC DAMPER ? � pressure. Selected size must have negative
O YES O NO
ALLOWABLE BACK PRESSURE AT OUTLET H20" 0 inches water column
COMPUTER SIZED STACK AT... 19.86 inches
PRESSURE STACK DIAMETER SIZE SELECTED... 24 inches
TOTAL PRESSURE LOSS OF SYSTEM... 0.12 inches
BACK PRESSURE AT OUTLET... -0.13 inches
BAROMETRIC PRESSURE... 22.16
SPECIFIC FLUE GAS WEIGHT AT SEA LEVEL 0.90
JOB NOTES: For 3 Boilers - 24" breechin will work
GENERALNOTES:
1. This program is based on ASHRAE, NFPA 211 and general data on product performance
2. This stack sizing program applies only to manufactured pressure stack from flus outlet to
termination. Sizing shouid be verified by manufacturer of stack being used with the specifi<
equipment supplied at the time of construction.
3. Changes to equipment and/or conditions requires a new calculation
4. All flue venting should be given priority routing over all other mechanical equipment.
Brent Wilson
From: Dave Baumann [daveb@engproducts.net]
Sent: Wednesday, November 16, 2011 11:13 AM
To: Brent Wilson
Subject: RE: Lodge Tower Boiler Replacement
Attachments: Copy of STACK CALC2.xls
Bret —
Attached is another stack analysis with (3) boilers. I came up with a 24" dia breeching this time.
I am not a code official, so I can't officially say if the 26" existing flue is compliant or not. Generally, you typically use B-
vent for a Category I boiler like the Thermific. If your vent is 12 gauge and welded, it is probably okay.
The termination can be a typical "china cap" on top of the stack. A new section of double wall stack above the roof would
probably be okay also.
Dave Baumann
Engineered Products Co
From: Brent Wilson [mailto:brentwC�randhmechanical.com]
Sent: Wednesday, November 16, 2011 9:57 AM
To: Dave Baumann
Subject: RE: Lodge Tower Boiler Replacement
Dave,
I am sorry but I misquoted the number of new boilers-we desire to install (3) new N2000 thermifics, like it is shown on
the drawing. 1) Would you please re-calculate the breach size with (3) N2000 Thermifics? 2) Again, will the existing 26
inch diameter flue work with the three? Are there any other code issues, and is a single walled 12 gage galv inside a
shaft that is wrapped by three layers of sheet rock? And 3) What type of termination do we need, and when outside
does that existing single walled termination above the roof need to be a NEW double walled B-vent? Please give me a
call to discuss if there are any clarifications that need to be made. I have also attached the same drawing for your
approval.
Thank you for your help,
Brent
970.328.2699 office
970.401.1744 cell
From: Dave Baumann jmailto:daveb@enqproducts.net]
Sent: Wednesday, November 16, 2011 8:39 AM
To: Brent Wilson
Subject: RE: Lodge Tower Boiler Replacement
Hello Brent —
The stack calcs show an 18" dia breeching will work, with (2) 12" dia connections to each boiler with barometric dampers
supplied with the boilers.
1
12 13/16" [325mm]
6 7/8" [173mm]
1 5/8" [41 mm]
P-K Thermif►c° Model N2000-2
S A
15 1/2° [393mm]
P
13 1/4" [336mm] 25 5/8" [651 mm] �
J
A
�1 � �
i
i
E
E E
E E �
E E � �
�' E �
m _
N � u pp
u �, � ' \
O�
aD I u � W
� N
o O E \ E
'�' E �o
� �
n
�
R in R �
N
�
E
11 1/4" [285mm] E
0
G °
�
The P-K Thermific' Boiler requires category I venting �
(non condensing—negative pressure) as defined in n
ANSI Z223.1/NFPA 54/CSA-6.149 Latest Edition.
BOILER CONNECTIONS:
QA Combustion Air Inlet 6" dio
QE Exhaust Vent 12" OD
QG Main Gas Connection 1 1/2�� NPT—F
� Wiring Junction Box 4" square
�P Pressure Relief Valve see list for selection
QR Boiler Water Return 2 1/2" NPT—M
QS Boiler Water Supply 2 1/2" NPT—F
FACTORY OPTIONS:
❑ Probe Type Low Woter Cut Off, Manual Reset (Factory Installed)
❑ Probe Type Low Woter Cut Off, Manual Reset (Shipped Loose)
O 2010, Harsco Industrial. Patterson-Kelley
E
E
�
�
W
�
�
3 1/2" [89mm]
� 25 5/8" [651 mm] �
6 t/8" [�55mmJ Service Clearonces:
24" [610mm] Both Sides
14 1/8" [359mm] 24" [610mm] Above
36" [914mm] Front
Electrical Requirements 120v, 1 ph, 60hz
Total Operating Amps less than 12 amps
Operating Weight 101 S Ibs.
Woter Content 7.3 gallons
A.S.M.E. Section IV Design Data
Maximum Pressure 160 psig
Maximum Temperature 250'F
Heating 5urface 206 sq ft
Flow Rate, GPM 120 min/150 max
HARSCO
INDUSTRIAL
Patterson-Kelley
Q1-30-2012
A . �'17 ........
,�r�:.rl �
Inspection Request Re�orting��,� �,
v��i r-n _ r�� n
Requested Inspect Date: Tuesday, January 31, 2012
Site Address: 200 VAIL RD VAIL
LODGE TOWER MECHANICAL ROOM
Page 16
A/PID Information
Activity: B11-0493 Type: COMBO Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: R-1 Insp Area:
Owner: LODGE TOWER HOA
Contractor: R& H MECHANICAL LLC Phone: 970-238-2699
Description: REP� CEME� �TWO MILL�ION B�TU BOILERS IN M CH�NICALEROOM,KELLY (LIKE KIND
Requested Inspection(s)
Item: 390 MECH-Final
Requestor: R& H MECHANICAL LLC
Comments: 471-5684
Assigned To: SGR M
Action: Time Exp:
� � �� I�
Inspection History
Item: 200 MECH-Rough
Item: 240 PLMB-Gas Piping
Item: 390 MECH-Final
Item: 90 BLDG-Final
REPT131
Requested Time: 11:30 AM
Phone: 970-238-2699
Entered By: JMONDRAGON K
Run Id: 14057