HomeMy WebLinkAboutF08-0081TOWN OF VAIL F IRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRON'T'AGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT 10/09/2008 Job Address: 2211 N FRONTAGE RD VAIL Location.....: 143 E MEADOW DRIVE Parcel No...: 210108202001 Project No OWNER SOLARIS PROPERTY OWNER LLC 2211 N FRONTATGE RD STE A VAIL CO 81657 APPLICANT FRONTIER FIRE PROTECTION 2617 WEST HOLDEN PLACE DENVER CO 80204 License: 446 -S CONTRACTOR FRONTIER FIRE PROTECTION 2617 WEST HOLDEN PLACE DENVER CO 80204 License: 446 -S Permit #: F08 -0081 Status ... . Applied .. Issued . . . Expires. .. ISSUED 10/09/2008 10/24/2008 10/09/2008 Phone: 303 - 629 -0221 10/09/2008 Phone: 303 - 629 -0221 Desciption: TEMPORARY STANDPIPE SYSTEM FOR NEW COMMERCIAL BUILDING ( SOLARIS) Valuation: $55,000.00 **s*#s##s#}s+}+*}*****#*##s#+s }s + * +s * * * * * * # # # # } +s + } }s +s + * * * ** #sss } +} FEE SUMMARY s}+s++}+****# s + #s #ss +s } +s * * * * * * * #s + # } } + * * + *# *sss #s +s * * * } * * ** Mechanical - -> $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > $2,687.50 Plan Check - -> $350.00 DRB Fee----------- - - - - -> $0.00 Additional Fees --- ------- > $0.00 Investigation -> $0.00 TOTAL FEES - -- $2,687.50 Total Permit Fee — -------- > $2,687.50 Will Call -- $0.00 Payments--------- - - - - -> $2,687.50 BALANCE DUE --------- > $0.00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 10/23/2008 McGee Action: AP teve 42 West Meadow Drive Vail, Colorado 81657 970 - 479 -2250 October 23, 2008 Steve Martin Frontier Fire Protection 2617 West Holden Place Denver, Colorado 80204 Re: Solaris Temp Standpipe Permit F08 -0081 Dear Steve; The plans for the temporary standpipe at the Solaris project are approved 1. Page 16 of 16 shows a 3 inch in -line Wilkins Z3004 PRV. The letter trom Fr( Sept 15, 2008 indicates under item # 2, that PRV's will be eliminated from the sti Either remove the PRV or provide an engineered explanation of why it is there. Thf do not indicate the minimum and maximum flows and pressures. No material cut sheet provided. 2. Material cuts sheets were provided but nothing on the plans or notes indicate the location of heavy fittings, Schedule 10 or Schedule 40 pipe or other relevant materials cut sheet for the Mega Flow does not indicate class or pressure ratings 3. Additional discussion is needed on the hydraulics for the fire pump. The cz provided for the final design indicate 100 psi will be available at the top FHV. '. appendices of NFPA 14, 2007 edition, Section A 7.8, discusses options fire departs use for high rise fire hose configurations. Vail Fire Dept. does in fact use the . example, 50 ft of 2 % inch, a wye and two 100 ft sections of 1 % in hose. Credit i fire hose length at 200 ft. The length of the fire hose would be restricted to 151 the current scenario. Demand pressures are calculated to be 120 149 psi. Nothing in the current plan for the temporary standpipe would need to be changed : of the outcome of the pending discussion on the hydraulics. Please submit a schedi indicating the schedule of pipe per location. Sincerely, Michael McGee Deputy Chief, FSSI 006 Vail Fire Department Response: October 23, 2008 Mr. Mike McGee, Deputy Chief /Fire Marshal Town of Vail, Fire and Emergency Services 42 West Meadow Drive Vail, Colorado 81657 1- 970 - 479 -2135 (Office) 1- 970 - 376 -0738 (Cell) mmcgee@vailgov.com RE: FIRE SPRINKLER PLAN REVIEW DATED 10 -23 -08 Solaris Project at 141 East Meadow Drive Vail, Colorado Dear: Mike: The following is our response to the plan review comments: 1. The 3" pressure reducing valve should not be shown on the temporary standpipe draN PRV is because the expansion tanks for the anti - treeze systems require the pressu: reduced to 125 PSI. 2. The schedule 40 pipe will be used on pipe sizes 1 thru 2 pipe and the schedule be used on pipe sizes 2 thru 8 ". The mega tlow pipe will be used in 2 -1/2" thru sizes only. The series S00 grooved fittings and couplings will be used on all pip( 1" thru 8 ". The lowest pressure rating on the grooved couplings is 300 PSI which I exceed the system pressure. The threaded titting will be ductile iron tittings in thru 2 -1/2" and are all rated at 300 PSI. 3. I pertormed a source calculation which will show how must pressure we can provide top fire hose valve and that is 119.83 PSI. Sincerely Yours, Frontier Fire Protection Wm. Steve Martin Vice President CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY -TWO HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. ATURE OF OWNEK-OR CONTRACTOR FOR HIMSELF AND OWNER ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R080002026 Amount: $2,687.50 10/24/200802:09 PM Payment Method: Check Init: SAB Notation: 010299 FRONTIER FIRE PROTECTION Permit No: F08 -0081 Type: SPRINKLER PERMIT Parcel No: 2101 - 082 - 0200 -1 Site Address: 2211 N FRONTAGE RD VAIL Location: 143 E MEADOW DRIVE Total Fees: $2,687.50 This Payment: $2,687.50 Total ALL Pmts: $2,687.50 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 SPRINKLER PERMIT FEES 2,337.50 PF 00100003112300 PLAN CHECK FEES 350.00 TOWN OF VE 75 S. Frontage Rd. Vail, Colorado 81657 T01 M OF VAIL FIRE SPRINKLER PERMIT APPLICATION Fire Sprinkler shop drawings are required at time of permit submittal and must include the following. Permit application will not be accepted without this information: • A Colorado Registered Engineer's stamp or N.I.C.E.T. Level III (min) stamp. • Equipment cut sheets of material • Hydraulic calculations. • A State of Colorado Plan Registration form. • Plans must be submitted by a Registered Fire Protection Contractp! CONTRACTOR INFORMATION Fire Sprinkler Contractor: Town of Vail Reg. No.: Contact and Phone #s: Frontfe_( Rf'e_ flrcte/_+ o f) 1 Vic. Steve_. M a vl 0 ( 3o 3) - ( - L 9 - 022 E-Mail Address: 1 5rn, - jr_hy1 0 Contractor Signature: J�% PLETE VALUATIONS FOR ALARM PERMIT (Labor & Materials) 7! Fire Sprinkler: $ Contact Eagle Count y Office at 970-328-8640 or visit www. eagle us for Parcel # Parcel# izl0lop,?n jy1& Job Name: Job Address: 145 avid 14 E, Meadow Pr Val CC) S1 (p5 Legal Description Lot: f Block: S - Filin Subdivision: a i 1 V F hn,3 I wners,.Namq: Address: 221 Wci- , fi e- Rol Suite- A Phone: �Do I a'" C511. prozet Ow 616,,51 970-q 11 -7 F �91 neer: 13CEK Inc, Address: 1542o war,) KA ) 3 422 - 7' Dt) ArvaAi , CO 80'002- i Detailed Location of work: (i.e., floor, unit #, bldg. #) 13u1 1,Affn Detailed description of work: n 7P_ Work Class: New ()() Addition ) Remodel ) Repair ) Retro-fit ( ) Other ( ) [Type ofBIdg.: Single-family( ) Two-family( ) Multi-family( Commercial( ) Restaurant( ) Other (N) Pl Use-1 No. of Existing Dwelling Units in this building: 0 Does a Fire Alarm Exist: Yes No hr 11 No. of Accommodation Units in this building: j7 Does a Fire Sprinkler Svstem-ExLst-- Yes( ) f F: \cd ev\FO RM S \Pe & es\Fi r7e6Vn nkf & perm =1U 19-06. TOWN OF VAIL 10/19/2006 — PHONE: (303) 629 -0221 FAX: (303) 623 -7830 517 West Holden Place, Denver, Colorado • 80204 INTIER F =RE PROTECTION xxc. FIRE PROTECTION ENGINEERS AND CONTRACTORS October 23, 2008 Mr. Mike McGee, Deputy Chief/Fire Marshal Town of Vail, Fire and Emergency Services 42 West Meadow Drive Vail, Colorado 81657 1- 970 - 479 -2135 (Office) 1- 970 - 376 -0738 (Cell) mmcgeegvaiIgov.com RE: FIRE SPRINKLER PLAN REVIEW DATED 10 -23 -08 Solaris Project at 141 East Meadow Drive Vail, Colorado Dear: Mike: The following is our response to the plan review comments: 1. The 3" pressure reducing valve should not be shown on the temporary standpipe drawing. The 3" PRV is because the expansion tanks for the anti - freeze systems require the pressure to be reduced to 125 PSI. 2. The schedule 40 pipe will be used on pipe sizes 1" thru 2" pipe and the schedule 10 pipe will be used on pipe sizes 2" thru 8 ". The mega flow pipe will be used in 2 -1/2" thru 4" pipe sizes only. The series 500 grooved fittings and couplings will be used on all pipe sizes from 1" thru 8 ". The lowest pressure rating on the grooved couplings is 300 PSI which will not exceed the system pressure. The threaded fitting will be ductile iron fittings in sizes 1" thru 2 -1/2" and are all rated at 300 PSI. 3. I performed a source calculation which will show how must pressure we can , provide you at the top fire hose valve and that is 119.83 PSI. Sincerely Yours, j Frontier Fire Protection s Wm. Steve Martin Vice President