Loading...
HomeMy WebLinkAboutF08-0063TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 161 -0 2 S SPRINKLER PERMIT Permit #: Job Address: 143 E MEADOW DR VAIL Status ... : Location.....: 143 E MEADOW DRIVE Applied .. : Parcel No...: 210108202001 Issued . . . Project No Expires. .: OWNER SOLARIS PROPERTY OWNER LLC 2211 N FRONTATGE RD STE A VAIL CO 81657 APPLICANT FRONTIER FIRE PROTECTION 2617 WEST HOLDEN PLACE DENVER CO 80204 License: 446 -S CONTRACTOR FRONTIER FIRE PROTECTION 2617 WEST HOLDEN PLACE DENVER CO 80204 License: 446 -S 08/27/2008 F08 -0063 q ISSUED 08/27/2008 11/25/2008 08/27/2008 Phone: 303 - 629 -0221 08/27/2008 Phone: 303 - 629 -0221 Desciption: NEW COMMERCIAL BUILDING ( SOLARIS): FIRE SPRINKLER SYSTEM Valuation: 1,798,000.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ***************************** * * * * * * * + * * * * * * * * * * * * * * * * * * * * * ** Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > $76,765.00 Plan Check --- > $350.00 DRB Fee --------------------- > $0.00 Additional Fees------ - - - - -> $287.00 Investigation -> $0.00 TOTAL FEES--------- - - - - -> $76,765.00 Total Permit Fee ---------- > $77,052.00 Will Call - - - -> $0.00 Payments------------ - - - - -> $77,052.00 BALANCE DUE --------- > $0.00 ssss*+++++**ss+**s++*++++*s+ss++*++*++++ss++++s+++s++s+s++++*+**+++s+++s+++*+++*s++s++++s+++*++s++s++s++*ss+s++s+* + + * * * + + + *s + + +s + + * + + + + * * + *sssss+ Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 09/05/2008 McGee Action: CR SOLARIS FIRE SPRINKLER PLAN 1. Please number pages # - # 2. Pressure reducing valve at water entry station may be set at 175 psi unies: essential to fire pump design. 3. Provide exploded detail on site plan with elevations for FDC's. 4. Provide detail on guards for drum drips. 5. Bike storage and water entry station must be separated. Shared use is not 6. Flow and tampers are not shown for elevator pit. 7. Standards require submittal on RCP's. Provide RCP's or address in plan note specification and cross section detail. 8. Page 3 Heads at top of page are shown 6 tt ott match line. Show spacing to] branch line. 9. Pages 6 & 7 Duplicate nodes in Hydraulic Remote Areas 2 and 3. Revise. 10. Page 10 Grid 2.7 / E Detail low point drain. Show Volume. 11. Page 11 Restaurant will need to be calc'd at min. Ord 1. 12. Page 17 Pipe chase appears to potentially present risk. Re- evaluate. 13. Page 18 No nodes shown for DP -4 14. Page 22 and 23 RCP's needed to resolve apparent cold solder issues. 15. Page 27 Heads and pipe must be min 14 ft AFF in Loading Dock. 16. No heads shown in outside canopy. Define "canopy ". 17. Symbol for 155 VK 124 and symbol for light fixtures are the same. Delete l: symbols. Toilet at Grid 8 / N appears to need additional coverage. 18. Page 28 Density in Main Lobby may require higher density depending on fuel ceiling height. Neither are shown. 19. Page 29 Grid R 23 handicap toilet may need additional coverage. 20. Page 33 Provide cross section of Unit 401. Provide information on method of point heads in antifreeze loop. 21. General Note: Owner's closets are not exempt from sprinkler requirement. 22. General Note: Coordinate nomenclature for flow and tamper zones with fire contractor and building door and room id's. 23. Page 42 Caution: Adhere to published data ref sloped ceilings (aka Tyco /UL paper) . 24.Page 46 Note implies standpipe in Stair 6 is on antifreeze system. Explain. 25. Page 48 Provide cross section for Unit 506 (sloped ceilings). 26. Page 49 Hanger notes refer to pressures under 100 psi. Show calc'd pressurE hanger notes as needed. 27. Page 51 Caution: Heads in bathrooms may deleted if under 54 sq ft. Use caul of calculation. Recommend contacting VFES for discussion on method of calculation structure does not provide minimum access as required by code. Heads may be requi: regardless of sq ft. 28. Page 55 Caution: Antifreeze systems require annual draining and remix. Pen( not drain. Potential freeze issue. Solaris Fire Sprinkler Plan Review F08 -0063 Page 2 29. Page 58 Provide cross section for Unit 701. 30. Page 65 PRV's on standpipes were eliminated via Admin Mod. Revise. 31. Page 68 Fire pump must be on EM Generator. End Michael McGee Deputy Chief FSSI 006 Vail Fire & Emergency Services 970 479 -2135 09/05/2008 09/05/2008 McGee Action: DN SOLARIS TEMP STANDPIPEPLAN REVIEW F08 -0063 1. Please number pages # - # 2. Page 1 gas notes including PRV's. Administrative Modification eliminated PI 3. Page 1 only shows stairs 2 and 4. Provide plan for each stair. 4. Plan implies phased approach. Submit over all phasing plan. 5. Provide overall site plan. 6. Point FHV's at 45 degree vs straight vertical (90 degree). 7. Recommend separate permit number for temp standpipe plan. 8. Temp standpipes must be located to provide coverage with 200 ft hose lines 9. Page 2 does not show FHV at standpipe Stair 1. 10. Scale not shown. 11. Page 3 Q 4 inch FDC to 6 inch riser. 12. Show temp FDC on site plan. 13. Method of attachment for temp standpipe is not shown. 14. Page 4 No standpipe shown in Stair 6. 15. Page 5 Pipe chase at D 13 indicates no auto sprinklers. This appears to be chase. 16.No standpipe shown in stair 3. 17. Page 6 Plans show isolation valves in laterals. Provide tampers or lock op( 18. FHV's not shown. 19. Page 7 shows Legend in Stair 6 but no standpipe. 20. Page 9 Isolation valve must be locked open or tampered Resubmittal is required. 11/25/2008 McGee Action: AP PHONE: (303) 629 -0221 FAX: (303) 623 -7830 2617 West Holden -Iace, Denver, Colorado • 80204 RONT:IBR F:1RB PROTECTJ:ON :ENe. FIRE PROTECTION ENGINEERS AND CONTRACTORS October 31, 2008 Mr. Mike McGee, Deputy Chief /Fire Marshal Town of Vail, Fire and Emergency Services 42 West Meadow Drive Vail, Colorado 81657 1- 970 - 479 -2135 (Office) 1- 970 - 376 -0738 (Cell) mmcgee @vailgov.com RE: FIRE SPRINKLER PLANREVIEWDATED 10 -23 -08 Solaris Project at 141 East Meadow Drive Vail, Colorado Dear: Mike: The following is our response to the plan review comments: 1. Plan note 5 on page 1 indicates the PRV's will be set at 130psi. Notes on page 2 indicate the PRVwill be set at 150psi. Please resolve apparent conflict. The note on sheet 2 was incorrect and will be changed to 130 PSI. This will prevent u: from over pressurizing the system with the pump pressure. 2. Page 14. Retail shops do not have isolation valves as discussed. Recommend a common feeder main for the retail level with isolation valves per shop. The Fire Department will not allow the entire floor to be turned offfor maintenance, remodel or revisions. Under the current design no TCO will be granted on that floor ifthere are unfinished areas that will require the fire sprinklers to be turned offto complete the work. We are working on feasibility to make this change, the routing of the sprinkler systems are through steel beam penetrations which makes it very difficult to add supply mains for each tenant. Al present one control valve will isolate as many as (5) tenants at one time. 3. Page 24 Apparent cold solder issue exists in Laundry. These sprinklers are up the steel beam pockets where they can not wet one another. 4. GENERAL NOTE: Slope is not shown on all locations. Plans are not on reflected ceiling plans. Some areas appear to have cold solder issues, possibly due to the lack ofRCP's. We are using the reflected ceiling plans given to us from the architect. Some of the ceiling layers are turned off for legibility. Let know where you are having problems with the ceiling information and we will add to the plans. All of the ceiling slopes were taken into consideration when we were laying out the sprinklers. 5. Page 33, Unit 401. Graphics are unclear compared to legend. Heads are undistinguishable from 90 degree elbows on sloped ceilings. Plans are in color but legend is not. I apologize for the graphics on the riser nipples in unit 401. outside circle should not have printed. This was autocad programming problem. We have fixed the problem and I can reprint this drawing if you would like. 6. Page 37 Ifblue lines indicate slope, the dimensions were left of /the plan. The cyan colored lines represent the steel beams and the blue lines represent ductwork. I can tum them off so they don't show up on the drawings. We show them for the installers to take dimensions off the steel beams. Dimensions will bf added once we complete the coordination process is completed. 7. Page 41 Please review spacing to insure sufficient pressure to provide coverage. Intended coverage is not shown on plan. We have made corrections to sprinkler spacing in unit 504 where sprinklers were shown 9 ft from wall. 8. Page 43 Unit 515 Review coverage. Appears there are some holes in coverage. Sprinkler coverage in this unit has been corrected. 9. Page 46 Slope is not shown. We have added ceiling slopes to the plan. 10. Page 67 Fire pump suction side should not have valves within 8 -10 diameters ofthe inlet due to turbulence. Reconfigure or provide manufacture's specification. We are proposing to relocate the backflow device, pressure reducing valve, and check valve to another room on level 1 in the parking garage. 11. Request meeting with Steve Martin and Dave Leiker to go over backflow issues and layout on Page 67. We have a meeting scheduled with you on Thursday. Sincerely ours, Frontier 're Protection Wm. Steve Martin Vice President Include: Materials submittals dated 11 06 08 per Dave Leiker, BOER, In addition: 1. Add low point drains at standpipes, pg 67 2. Add flow switch at main riser for sprinklers. 3. Identify riser Detail B, riser diagram. 4. Install OS &Y's at RPBD (typical) pg 32 CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ss* s***** ss*** sssssss** ss* ssss*** s* sssss** s* s** ss* sss* s*** s* s* s****** ss* s* ssss* ss* ss* sss* s* s** s* sss*** s*********** * * * * * * * * * * * * * * * * *ss * *s * * * *s *sss DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY -TWO HOURS I ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R080002260 Amount: $77,052.0011/25 /200812:52 PM Payment Method: Check Init: LC Notation: #010317 /FRONTIER FIRE PROTECTION INC ----------------------------------------------------------------------------- Permit No: F08 -0063 Type: SPRINKLER PERMIT Parcel No: 2101 - 082 - 0200 -1 2101 - 082 - 0100 -2 2101 - 082 - 0100 -3 Site Address: 143 E MEADOW DR VAIL Location: 143 E MEADOW DRIVE Total Fees: $77,052.00 This Payment: $77,052.00 Total ALL Pmts: $77,052.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 SPRINKLER PERMIT FEES 76,647.00 CL 00100003123000 CONTRACTOR LICENSES 55.00 PF 00100003112300 PLAN CHECK FEES 350.00 ----------------------------------------------------------------------- - - - - -- TOWN oFVn� APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED F"S -OSI�q Project #: Building Permit #: Bo9- 02"15 Sprinkler Permit #: Fos - 60(o3 75 S. Frontage Rd. Vail, Colorado 81657 TOWN OF VAIL FIRE SPRINKLER PERMIT APPLICATION Fire Sprinkler shop drawings are required at time of permit submittal and must include the following. Permit application will not be accepted without this information: • A Colorado Registered Engineer's stamp or N.I.C.E.T. Level III (min) stamp. • Equipment cut sheets of materials. • Hydraulic calculations. • A State of Colorado Plan Registration form. • Plans must be submitted by a Registered Fire Protection Contractor. CONT RACTOR INFORMATION Fire Sprinkler Contractor: Town of Vail Reg. No.: Contact and Phone #'s: F:ront►er Fire Prvtaz; 6n 1 4444 --S Steve. Mart) 003} - IA91- 0221 ALE - Mail Address: A G f'ronti erf i re protw -tion . c-oM -1 Contractor �612- COMPLETE VALUATIONS FOR ALARM PERMIT (Labor & Materials) Fire Sprinkler: $ 1, 853 000. °O Contact Eag Coun Assessors Office at 970 - 328 -8640 or visit www. eaalecounty, us for Parcel # Parcel # 21p1oB2o1C>02 an-1 210106241003 Job Name: Solar-i5 Dg4e- 1opme - nt Job Address: 14'3 and 14 E. Me ,Acw Dr iYe- co Legal Description Lot: p Block: 5 p Filing: Subdivision: Vail V� ll e. F i I i n!3 1 Owners Name: Pr N� LI.L Address: 2Zt` Nor fi-ont�a9a VA, 564 - e.A oar Phone: 970- 'x'79 -7138 E. BGER Encg►v►ee ret" , lvtc . Address: SyZO wa►-d Rd ., � Z Phon e: 3v3 - y22 - 7L{ ob Detailed Location of work: (i.e., floor, unit #, bldg. #) Solari s F>61win9 Detailed description of word a1rDMA+ e- Fig,. 5prin for 5ol6tri5 Work Class: New ( Additl9IT1 Remodel ) Repair( ) Retro -fit ( ) Other ( ) Type of Bldg.; - fa mily ( ) T wo -famil Multi - famil Commercial ( ) Restaurant ( )Other (X) wax No. of Existing Dwelling 'k Nn o Units in this building: 77 Does a Fire Alarm -- Yes--F +-- No (X) -- - ._ ire Sprinkler System Exist: Yes( ) N6 o ()( ) b OFFICE USE ONLY * * * * * * * ** u� A )G 2 7 2006 TOW OF VAIL F: \cdev \FORMS\ Permits \Fire \sprinkler _perm_10- 19-06.DOC 10/19/2006