Loading...
HomeMy WebLinkAboutF11-0067TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 -479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Job Address: Location.....: Parcel No...: Project No 1451 BUFFEHR CREEK RD VAIL 210312102011 OWNER DYROFF, MATTHEW C. 11/21/2011 2033 11TH ST 6 Total Calculated Fees --- > BOULDER Plan Check --- > CO 80302 $0.00 APPLICANT PHOENIX AUTOMATIC SPRINKLER 11/21/2011 7684 S BRENTWOOD ST $0.00 TOTAL FEES--------- - - - - -> LITTLETON Total Permit Fee ---------- > CO 80128 Will Call - - - - -> License: C000003080 CONTRACTOR PHOENIX AUTOMATIC SPRINKLER 11/21/2011 7684 S BRENTWOOD ST LITTLETON BALANCE DUE --------- > CO 80128 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** License: C000003080 Permit #: F 11 -0067 Status ...: ISSUED Applied..: 11/21/2011 Issued . .. 12/09/2011 Expires . .: Phone: 303 - 523 -2098 Phone: 303 - 523 -2098 Desciption: ADDITION TO EXISTING FIRE PROTECTION SYSTEM TO COVER EXISTING HOUSE. Valuation: $5,755.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > $676.59 Plan Check --- > $432.00 DRB Fee --------------------- > $0.00 Additional Fees------ - - - - -> $0.00 Investigation -> $0.00 TOTAL FEES--------- - - - - -> $676.59 Total Permit Fee ---------- > $676.59 Will Call - - - - -> $0.00 Payments ------------------- > $676.59 BALANCE DUE --------- > $0.00 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 12/05/2011 McGee Action: AP Approved on performance basis per submitta received 12 05 20. CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -, OURS IN ADVAN� ELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SICNATVRV-,@f OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADO Statement Statement Number: R110001757 Amount: $676.59 12/09/201102:10 PM Payment Method:Credit Crd Init: LC Notation: CREDIT CARD FROM RONALD W KELLEY, PHOENIX AUTOMATIC SPRINKLER ----------------------------------------------------------------------------- Permit No: Fll -0067 Type: SPRINKLER PERMIT Parcel No: 2103 -121- 0201 -1 Site Address: 1451 BUFFEHR CREEK RD VAIL Location: Total Fees: $676.59 This Payment: $676.59 Total ALL Pmts: $676.59 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 SPRINKLER PERMIT FEES 244.59 PF 00100003112300 PLAN CHECK FEES 432.00 FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: 1451 BUFFEHR CREEK RD (Number) (Street) (Suite #) Building /Complex Name: Contractor Information: Company: PHOENIX FIRE PROTECTION Company Address: 7684 S. BRENTWOOD ST. City. LITTLETON State: CO Zip 80128 Contact Name: RON KELLEY Contact Phone: 303 - 523 -2098 E- Mail wfprotection1 @gwestoffice.net Town of Vail Contractor Registration No.: 652 -S ` DigiFPE,, tally signed by Deborah Shane. k S hanerDNFPE, o.ah Shane.,o= Shane.Elf,Safety. u= maiL- shanerls @comcascnet. c =US Contractor Signature (required) Property Information Parcel #: 2103- 121 -02 -011 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Owner Name: DYROFF, MATTHEW C. Office Use: (� Project #: P 09 — aLI Building Permit # — Q 1 I5 Sprinkler Permit #: El I " Dn(o 1 Lot #: Block # Subdivision: Detailed Description of Work: Additio to e xisting fire protection system to cover existing house. Design is performance based using NFPA 13D. (use additional sheet if necessary) Detailed Location of Work: Existing area of house. Modified NFPA 13D. Does a Monitored Fire Alarm Exist? Yes ( v) No ( ) Does a Sprinkler System Exist? Yes (v) No( Work Class: New ( ) Addition ( ) Remodel ( ) Repair ( ) Retro -Fit ( v ) Other ( ) Type of Building: Single - Family (v) Duplex ( ) Multi - Family ( ) Commercial ( ) Restaurant ( ) Other ( ) Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler $: $5755 Department of Community Development .,.. 75 South Frontage Road y< Vail, Colorado 81657 Tel: 970 - 479 - 2128) Fax: 970-479-2452 r ; , Web: www.vailgov.com r)PVPlnnmPnt.Ravicauu Cnnrr1inafniai. Date Received: ��_EHW[E NOV 17 2U11 D TOWN OF VAIL 01- Feb -10 PO Box 1073, Frisco, CO 80443 970.409.9082; fax 970.797.1898 November 14, 2011 Mike McGee Vail Fire & Emergency Services Re: Dyroff Residence, fire protection system Dear Deputy Chief McGee, This letter is in regards to the fire protection system at the Dyroff residence located at 1451 Buffehr Creek Road in Vail. As you are aware, an addition was recently installed onto this home and was provided with a fire protection system. However, during that scope of work, the existing home was not sprinklered. To remedy this situation, the parties involved met to determine a feasible solution. This group included myself as the owner's Fire Protection Engineer, Ron Kelley with Phoenix Fire Protection, Matt Dyroff as the homeowner and yourself as the representative from Vail Fire and Emergency Services. We have determined that both the fire alarm and fire protection systems need to be expanded into the existing home. The fire alarm work will be addressed under a separate permit and letter. The existing home did undergo an extensive remodel in the recent past. The finishes in the home have made it extremely difficult to install a fire protection system throughout per the prescriptive requirements of applicable codes. It would be a hardship for the owner to meet these requirements. Therefore, we would like to offer an alternative for installation of the fire protection system. The proposed design would be a performance based design using NFPA 13D, modified to accommodate the difficult installation. A sprinkler head layout is attached. Phoenix Fire Protection will follow with shop drawings and hydraulic calculations. Based on hydraulic information available, I have no concerns about the hydraulics of the system. Piping will be run through the crawl space and up through walls to reach the covered areas. As you can see, the sprinkler head layout does not precisely meet the requirements of NFPA 13. However, I would make the statement that the sprinkler heads will all be installed in accordance with their listing. The heads will be mounted at heights allowed by manufacturer recommendations and will all be UL listed residential, quick response, sidewall, extended coverage heads. Sprinkler heads are to be provided in areas posing a viable fire hazard. They have been placed to maximize the coverage from each head. We have excluded closets, bathrooms, the garage and vestibule areas. Large rooms are covered to the extent possible while minimizing the impact to the homeowner. As the project Fire Protection Engineer, I believe that this system design will provide adequate coverage to suppress fires in likely locations. Based on my knowledge of fire protection systems, I am comfortable with this system design and approve it for installation in the Dyroff home. We request a permit so that Phoenix may proceed. If you have any questions or need further information, please do not hesitate to contact me. Sincerely, �EIG` Deborah L. Shaner, P.E. Fire Protection Engineer • aiii�ti Cc: Ron Kelley, Matt Dyroff