ALARM PERMIT
Job Address: 186 GORE CREEK DR VAIL
Location.....: LODGE AT VAIL - UNIT 154
Parcel No...: 210108221015
Project No
OWNER TOCHTER LLC
PO BOX 2736
EDWARDS
CO 81632
APPLICANT SIMPLEX GRINNELL
6240 SMITH RD
DENVER
CO 80216
License: 903 -S
CONTRACTOR SIMPLEX GRINNELL
6240 SMITH RD
DENVER
CO 80216
License: 903 -S
11/21/2011
Permit #: All -0065
Status ...:
ISSUED
Applied..:
11/21/2011
Issued. .:
12/13/2011
Expires. .:
06/10/2012
11/21/2011 Phone: 303 - 355 -0500
11/21/2011 Phone: 303 - 355 -0500
Desciption: MOVE SPEAKER AND HEAT TO CEILING. REPLACE SPEAKER WITH
SPEAKER STROBE PLUS REPLACE HAT WITH SMOKE AT END OF
CONSTRUCTION.
Valuation: $1,565.00
##################################### # # # # # # # # # # # # # # # # # # # # # # # # # # # # # ##
FEE SUMMARY ########################## # # # # # # # # # # # # # # # # # # # # # # # # # # # # # ##
Electrical --------- >
$0.00
Total Calculated Fees - ->
$346.69
DRB Fee --------- >
$0.00
Additional Fees ---------- >
($130.69)
Investigation ---- >
$0.00
Total Permit Fee--- - - - - ->
$216.00
Will Call --------- >
$0.00
Payments ------------------ >
$216.00
TOTAL FEES -->
$346.69
BALANCE DUE--- - - - - ->
$0.00
############################################################################################################## # # # # # # # # # # # # # # # # # # # # # # # # # # # # # ##
Approvals:
Item: 05600 FIRE DEPARTMENT
11/28/2011 mvaughan
Action: AP
############################################################################################################## # # # # # # # # # # # # # # # # # # # # # # # # # # # # # ##
CONDITIONS OF APPROVAL
############################################################################################################## # # # # # # # # # # # # # # # # # # # # # # # # # # # # # ##
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS INADVAN'I r_XV, TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM.
TURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
TOWN OF VAIL, COLORADO Statement
Statement Number: R110001767 Amount: $216.00 12/13/201102:54 PM
Payment Method: Check Init: LC
Notation: #055366/NEW
ELECTRIC INC.
-----------------------------------------------------------------------------
Permit No: All -0065 Type: ALARM PERMIT
Parcel No: 2101 - 082 - 2101 -5
Site Address: 186 GORE CREEK DR VAIL
Location: LODGE AT VAIL - UNIT 154
Total Fees: $216.00
This Payment: $216.00 Total ALL Pmts: $216.00
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
PF 00100003112300 PLAN CHECK FEES 216.00
0
Department of Community Development
,. 75 South Frontage Road
,... Vail, Colorado 81657
Tel: 970 -479 -2128
Fax: 970 -479 -2452
Web: www.vailgov.com
evelopnient Review Coordinator
FIRE ALARM PERMIT
Commercial and Residential Fire Alarm shop drawings are required at the time of application
submittal and must included information listed on the 2nd page of this form. Application will
not be accepted without this information.
Project Street Address:
(Number) (Street) �� (Suite N)
Building /Complex Name: 4 v Qc-i l/�/
Office Use:
Project #: &T I t - t) / 1 5
Budding Permit # RI L.- pgnq
Alarm Permit #A 1) " 60465
Contractor lnf! r nation: Lot # _ Black # _ Subdivision I
Company. L'�l"( PC & 41Z - 1 AJ0f r G-
Company Address lr, !� (�yZ"T,+tf �!� Detailed Scope and Location of Work 1�'Py' .5 R
City L /U e IL St /ate $0 Zip.
Contact Name / ,K - „ �Lt/l?GZ� />�irO•c� rev Pct' �S 17t MQf"L [/ P6JfC"+ /7�iI'�`
Contact Phone C ��''rwv
E-Mail 6 "4 G v^r J �� 7+ 3 �E�' /i t t fuse additional : - "- heel if necessary) e - F
Town of Vail contractor Rey Does a Monitored Fire Alarm Exist? Yes 01) No
�straf n o
�L k Does a Sprinkler System Exist? Yes (,W No( )
X ( / c J : c.Ga # -* ,
Contractor Signature (required)
Property Information
Parcel #
(For parcel #. contact Eagle County Assessors Office at 970 - 328 -8640 or
visit www eaglecounty usrpatw)
`
Tenant Name: ) K t`h t �Y (/fi<i>Z" �t d�M�1` Tlt' .�'
Owner Name
Work Class:
New ( ) Addition ( ) Remodel X Repair j )
Retro-Fit ( ) Other ( )
Type of Building:
Single -Family ( ) Duplex ( j Multi - Family ( )
Commercial k< Restaurant ( ) Other ( )
Date Received:
Complete Valuation for Fire Alarm Permit. //
Fire Alarm S 1S(, 5 �^
A)cAj 1 e G( i7t r' I2 lK (/f'
Nov 18 2011
TOWN OF VAIL
f rn i;
��� +V FMCv
Fire Department Process
For Commercial & Residential Fire Alarm Systems
Commercial and Residential Fire Alarm shop drawing requirements at the time of submittal must include the
following.
This check list has been provided to ensure that our review process may be handled in a timely manner.
I have read and understand the above listed submittal requirements /!�i y4w ,. c Oep �"M c G y
Protect/Street Address C zt F , dR' + A; 4'r/ ,
Contractor Signature
Date Signed
0146 -io
A Colorado Registered Engineers stamp
k/
Device locations on reflected ceiling plans
Reflected Ceiling Plans (RCP)
Typical device wiring diagrams
Battery calculations
Battery calculations
A list of specific device model numbers
U)
Equipment cut sheets of each type of device
The number of each type of device
J
Information indicating the specific zones
'
Circuit diagrams
Point to point wiring diagram
Wiring type size and number of conductors
'
The source of AC power circuits
Fire alarm panel locations
Knox Box location
Information indicating monitoring method and monitoring agency
This check list has been provided to ensure that our review process may be handled in a timely manner.
I have read and understand the above listed submittal requirements /!�i y4w ,. c Oep �"M c G y
Protect/Street Address C zt F , dR' + A; 4'r/ ,
Contractor Signature
Date Signed
0146 -io
�- �A11 fig
Fire Department Guidelines
J For Preventing Non-Emergency
9 Fire Alarms
V k � pV �Mcv at
In order to prevent a non - emergency response from the Vail Fire Department Suppression crews to the con-
struction location you may be working on. we ask that you perform the following tasks
4. ttl
(� C-14,...
C w_
Determine what kind of fire alarm system exists within the structure you are
working in with the owner or the manager of the property involved or by contact-
ing the Vail Fire Department
Determine with the owner or manager of the property, which alarm company
services the system for them
Become familiar with the different components that are associated with the fire
alarm system and how they operate before the DEMO begins.
Never paint a smoke detector thermal detector, or any other component of the
fire alarm system and never paint a sprinkler head /cover plate
For larger projects please contact the Vail Fire Department so that we can
work with you in determining what needs to be done to alter or "Zone Out spe-
cific areas of the alarm system for the structure
Please contact the Vail Fire Department at 479 -2252.
I have read and understand the above listed submittal requirements-
Project/Street Address
Contractor Signature:
Date Signed
01•R3g•10
// /11 Z,/
O. Simplex
TrueAlert" Notification Appliances
UL Listed: FM. CSFM. Speaker/Visible Notification Appliances with TrueAlert
and MEA (NYC) Approved' Non - Addressable Strobe; Round, Ceiling Mount
Audible /visible ceiling mount notification
appliance with:
Multi- tapped speaker
High intensity xenon strobe, selectable for free -run or
synchronized flash
Audible notification appliance (speaker):
• High quality voice and tone reproduction with taps for
1/4, 112. I, or 2 W, at 25 or 70.7 VRMS
UL listed to Standard 1480
Speakers are wired separately from strobe wiring
TrueAlert non - addressable visible notification
appliance (strobe):
Models available with 15, 30, or 110 candela
24 VDC operation with switch selection for free -run
or synchronized flash rate**
• UL listed to Standard 1971
• Compatible with ADA requirements
• Strobe candela rating is clearly indicated on reflector
• Rugged, high impact, flame retardant thermoplastic
housing
Synchronized flash rate mode for use with:
Synchronization modules for Class 13 style Y) or
Class A (Style L) operation
Notification appliance design provides:
• Round housing for ceiling mount in standard
electrical boxes
• Separate in/out wiring terminals for speaker and
strobe
Description
TrueAlert non - addressable speaker /visible (SN)
notification appliances combine a multi- tapped
speaker and a high intensity strobe to provide audio/tone
notification and visible notification from the same
appliance.
Speakers and strobes are wired separately. The speaker is
multi - tapped with taps available for either 25 VRMS or
70.7 VRMS and the strobe is selectable for either free -run
or synchronized operation.
se
Ceiling Mount TrueAlert Non- Addressable SN Appliances
Feature White Housings with Red Lettering
Strobe Selection
Proper selection of visible notification is dependent on
occupancy, location, local codes, and proper applications
of: the National hire Alarm Code (NFPA 72), ANSI
A 117.1; the appropriate model building code: BOCA,
ICBO, or SBCCI; and the application guidelines of the
Americans with Disabilities Act (ADA).
Strobe Oneratinn
TrueAlert non - addressable SN strobes can be set
for free -run operation or synchronized operation using an
on -board selection switch. When selected for synchronized
operation, flash operation is controlled from:
• Synchronized Flash Modules. 4905 -9914 (Class B)
or 4905 -99212 (Class A)
• 4006, 4008, 41000, and 4010 Fire Alarm Control
Panels (refer to individual product data sheets for
details)
• 4009 IDNetT" NAC Extender, models 4009 -9201 and
•1009 -9301 (refer to data shot 54009 -0002)
This Vwuci has peen awavee M the CallornAa State Fire Me" (CSF4 Wu t to
Section 13144 1 of the Cailerrw Heath aped gaiety Cade. See CSFM L*&V
73240026 242 hx abvabb valim antler condows cwcwrwq maWO vesarUd in us
doasrov tt s subod to M-Nuan how. revision and poss+Dis carcelat m tipoeGaed for
use - C4ty Y New York 6eWffwt or 9uidr+ps - MEA35-93E The product was na ULC
i5to9 as or document revison date A4dftnal ls"$ may be apptcaw. contact tow beat
S+ V*A produa WOW for the least status Ltstngs and approvals under Serpler To*
Recorder Co. are ere properly or Tipp Selety Products % sonnster
S4903. 0019 -4 412005
Speaker /Visible Round Ceiling Mount Notification Appliances with TrueAlert Non - Addressable Strobes
Model Number Strobe Output Ratin41
i 15 cd 30 cd 110 cd
4903 -9196 J
4903 -9197 J
4903 -9198
Synchronized Flash Control Modules
Model Description
Synchronized Flash Module,
x905 -5914 Class B S Y o Epoxy encapsulated with in /out
(Style ) operation 18 AWG (0.82 mm wire leads.
4905 -9922 Synchronized Flash Module, rated for 2 A NAC, requires
Class A (S tyte Z) operation i 5 mA for power
Housing Color
White with red
"FIRE" lettering
Dimensions
1 -3/8" W x 2 -7/16" L x 13116 H
(35rnmx62rnmx20mm)
r��c aavi ics
Model I Description
2905 - 9946 ! Tile Bridge
4' (102 mm) square. 1.12' (38 mm) deep
box with 1 -12" extension (by others)
Wiring input terminals and
speaker tap selection are \
accessible from rear of
speakerhousing i
Dimensions
See diagram on pane 4
I
i
Selection switch for free -run or
synchronized flash is behind strobe
assembly, determine operation
before inserting into housing
2 54903- 00194 42005
-2-
SN Saeciflcatlons
Strobe Specifications
Rated Voltage Range UL Listed Range
_ UL C Listed Range
Regulated 24 VDC; see Notes 1 be
Power Taps
20 VDC to 30 VDC per ULC S526 -M87
— —
Flash Rate and Synchronized NAC Loa ding
1 Hz; with up to 35 s nchronized strobes maximum
per NAC
Maximum RMS Current Rating per Strobe
Output (see Note 2 below)
15 cd
30 cd
110 cd
80 mA
128 mA
285 mA
Reference Currents 18 VDC
at other voltages 24 VDC
80 mA
114 mA
253 mA
60 mA
85 mA
190 mA
Speaker Specifications
Input Voltage
25 or 703 VRMS, see Note 3 below
Power Taps
114, 112, 1, and 2 W
Fire Alarm Frequency Response
400 to 4000 Hz
Speaker Output Watta Tap
114 w
112 W
1 w
2 w
Ratings (dBA) UL 1480 Reverberant
10 ft (3 m) Chamber Rating
79
82
85
_
88
General Specifications
Housing Dimensions (including lens) 7 -1/4" H x 5' W x 2 -5/8' D (184 mm x 127 mm x 67 mm)
Depth into Box 2 -1/4" (57 mm)
Speaker Tap Selection Single ju mper wire with pressure connector, attaches to one of 8 terminals
Temperature Range 32- to 122 F (O- to 50v C)
Humid Range 10% to 9 3%, non- condensing at 100 F (38° C)
Connections Terminals for 18 to 12 AWG (0.82 mm` to 3.31 nim'), separate terminals for
speaker and strobe connections
NOTES:
1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the
Hearing Impaired, changes effective May 1, 2004 This voltage range is the absolute operating range. Operation outside
of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage
that is allowed at the last appliance on the NAC under worst case conditions. The strobe of this A/V is field selectable for
free -run or synchronized operation.
2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum
RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the
effective value of a varying current waveform.)
3. Speakers are for connection to conventional fire alarm audio circuits.
S4903- 0019 -4 4!2005
-3-
3 -314" (95 mm) square 0.024" thick sheet metal, folded with
cutout, centered on plate 1/2" lip each side
r
1/2" _
(13 mm) 13 -3/8"
o� o
t (340 mm)
1/4" diameter (6 mm)
holes, 4 places
6- 11/16"
(170 mm)
(+— 23- 11116" (602 mm)
1 u -• Simples, the Ntmplet logo, It 1A'et and 1YatNlrrt art troulemor£i of 1 1t r+ lntrmattonal 4rnvre.+ Ar i or to rt/11hatr.+ to the t •:S, tntd or wher rnuxme.t NVA4 '1 and
Nantowl t• or Alarm Codr arc rewmered trvdre arf.. of rAr Noturnrd Foe pnNriruwt A•nxrartnn CWTAt
93. . Tyco Safety Products Westminster • Westminster MA • 0144 1 -000 1 • USA S4903- 0019 -4 412005
www tycosafetyproducts- use -wm corn
t' AV.1 N C.Vm,'Wer All rr.0at rr wr%rd All ya•egtaxx"% A #k-r loiAw xkm ow" wrm "ummt o, q d+kument rrnw" rknr and on° wh /rtt to <iurtla rrh no nrru r