Loading...
HomeMy WebLinkAboutB11-0481 comment letter Date: November 21, 2011 Re: B11-0481 2692 Cortina Lane Dear Mr Raisch RESPONSE INSTRUCTIONS ● Submit two complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. ● Please respond in writing to each comment with a response letter addressing each comment. BUILDING COMMENTS Architectural Comments: General 1. Provide a site plan showing the location of the proposed project in relation to buildings, utilities, and property lines. Reference section R106.2 IRC 2. What is the height of the proposed structure and how is the deck accessed? Provide details of the proposed stairs and handrails if used for access. 3. Guard rail detail requires the openings to be less than 4” if the deck is over 30” above grade. Reference section R312.3 IRC. Revise plans Structural Comments: Sheet S1 1. Show the complete load path connection for the column to girder to joist. Plumbing Comments: NA Mechanical Comments: NA Electrical Comments: NA PLANNING COMMENTS Reviewed and accepted FIRE COMMENTS NA PUBLIC WORKS COMMENTS NA Sincerely, Martin A. Haeberle Chief Building Official