HomeMy WebLinkAboutB11-0017 Roof tie down approved
SUBMITTAL REVIEW
�
�
R. A. NELSON & ASSOCIATES, INC.
�
� Jeremiah Wendell 19Oct11 S05-5000-007 REVIEWED FOR GENERAL ARRANGEMENT. REVIEW SUBJECT TO COMPLIANCE WITH ALL CONTRACT REQUIREMENTS. DETAILED DIMENSIONS AND
QUANTITIES NOT CHECKED. MARTIN/MARTIN, INC. Date Received: _________ Reviewer: ERS Date Returned: 10/24/2011 EXCEPTIONS AS NOTED 1. GC to review all lengths and elevations. 2. Please
hot-dip galvanize assembly. Provide gas release vent hole in center of bottom plate (if required). 3. Roof anchor plate is called out as a deferred submittal on 4/S610. As a no-cost
substitution option, contractor may follow comments below. 10/20/2011 1/4" Masticord bearing pad per 4/S610. Please provide provide either HSS6X0.375 per 4/S610, or 6"ØXS pipe (allowable
no-cost substitution option). Owner to review and accept based on intended roof access equipment. Max hole = Ø1.5" Please provide 3/4" thick plate. Please provide 5/16" fillet weld each
side. �
� �
�
�
�
�
� �
� X BRANDON MIXON 11.4.2011
Martin 12/08/2011 TOWN OF VAIL REVIEWED FOR CODE COMPLIANCE Date ________