Loading...
HomeMy WebLinkAboutB11-0510NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES _ ,. 1!1�' OF YAii,,_• Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2133, f. 970.4792452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Perrr�it #: B11-0510 Project #: PRJ11-0725 Job Address: 160 GORE CREEK DR VAIL Applied.....: 12/15/2011 Location......: LODGE AT VAIL COMMERICAL SPACE Issued. ..: 04/17/2012 Parcel No....: 2101082?_1004 CONTRACTOR SRE BUILDING ASSOCIATES 04/12/2012 Phone: 970-945-6359 PO BOX 6376 VAIL CO 81658 License: C000003460 OWNER MOUNTAIN WOLF PROPERTIES LLC 12/15/2011 6532 VIA ROSA BOCA RATON FL 33433 Description: TENANT IMPROVEMENT REMODEL RETAIL INTO BAKERY (MOUNTAIN CUPCAKE) Occupancy: M Type Construction: IIB Valuation: $80,000.00 ....z�......�.,�......�,.........<.,....,,,....x.>...x.»......,,..>..>.....,,... . FEE SUMMARY ................x...................�.�,.�......�............,.,.,.,,..xx,...... Building Permit -----------> $853.75 Bldg Plan Check ----------> $554.94 Use Tax Fee-----------------------> $1,400.00 Electrical Permit ---------> $690.00 Elec Plan Check -----------> $448.50 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $400.00 Mech Plan Check ---------> $100.00 Additional Fees--------------------> $75.00 Plumbing Permit --------> $300.00 Pimb Plan Check ---------> $75.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 TOTAL PERMIT FEES--------------> $4,917.19 Payments-------------------------------> $4,917.19 BALANCE DUE------------------------> $0.00 ..............x.............xxxx.........x.z�.........z......,.,...�.......,.......,......«.............,,.........,.......,,.......,<...,,,..........xxxx...,..,,.�.�...,....,...,,...,. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. R�QUESTS FOR INSP CTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8: 0 AM - 4:00 PM. 1�� ��� Signature of Owner or Contractor Date �v.c� S hn.� U�. Print Name combination permit_012811 ,�,ri.»..» ..............�....�......,,,,,.x.x.x„>,,,x..,x...............,.,,........,...�,,...x,,,x,,..,.,..x...,,,.,..«..,,.,..,,..,,,...�.,.......,.,,..x.�,.>,...�»�......,.,,�... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 611-0510 A�dress: 16Q GORE CREEK �R VAIL Owner: MOUNTAIN WOLF PROPERTIES LLC Location: LODGE AT VAIL COMMERICAL SPACE .,,�......<,.<x�>,.,>..,�,x,.,,....,.,>,....,..,,.,�...........� ...................«„>,...,.......,».,.,....,.,�,�,..�..,........,,........,,.,....,.�..............,.,........... Cond: CON0012390 Rock resorts/Lodge at Vail has been advised that completion of sprinkler retrofit order is required. This is not a condition of approval for the applicant, however, the landlord is expected to complete sprinkler layout. combination permit_012811 ******************************************************************************************** TOWN �F VAIL, CC�L��RAL'O Statemer.t ******************************************************************************************** Statement Number: R120000290 Amount: $3,000.00 04/17/201203:31 PM Payment Method:Credit Crd Init: SAB Notation: MC-LAUREN SMITH ----------------------------------------------------------------------------- Permit No: B11-0510 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-2100-4 Site Address: 160 GORE CREEK DR VAIL Location: LODGE AT VAIL COMMERICAL SPACE Total Fees: $4,917.19 This Payment: $3,000.00 Total ALL Pmts: $3,829.19 Balance: $1,088.00 **************************************�*****************************+********++************* ACCOUNT ITEM LIST: Account Code BP 00100003111100 EP 00100003111100 MP 00100003111100 PF 00100003112300 PP 00100003111100 UT 11000003106000 WC 00100003112800 Descriptiori BUILDING PERMIT FEES ELECTRICAL PERMIT FEES MECHANICAL PERMIT FEES PLAN CHECK FEES PLUMBING PERMIT FEES USE TAX 4% WILL CALL INSPECTION FEE Current Pmts 829.50 690.00 400.00 948.50 300.00 312.00 20.00 ***************************************************+**+************�*��***************�***** TOWN OF VAIL, COLORADO Statement *************************************************�****�************************************* Statement Number: R120000289 Amount: $24.25 04/17/201203:30 PM Payment Method: Cash Init: SAB Notation: CASH-LAUREN SMITH ----------------------------------------------------------------------------- Permit No: B11-0510 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-2100-4 Site Address: 160 GORE CREEK DR VAIL Location: LODGE AT VAIL COMMERICAL SP�CE Total Fees: $4,917.19 This Payment: $24.25 Total ALL Pmts: $829.19 Balance: $4,088.00 *********************************�*******++***************+********************************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 24.25 ****************************+*************************************************************** TOWN OF VAIL, COLORADO Statement ********�**************************************�**************************+***************** Statement Nnmber.: �17_OOOC291_ Amc>;nt: $?,088.00 09/1?/2012.03:32 pM Payment Method:Credit Crd Init: SAB Notation: VISA-LAUREN SMITH ----------------------------------------------------------------------------- Permit No: B11-0510 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-2100-4 Site Address: 160 GORE CREEK DR VAIL Location: LODGE AT VAIL COMMERICAL SPACE Total Fees: $4,917.19 This Payment: $1,088.00 Total ALL Pmts: $4,917.19 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ DT 11000003106000 USE TAX 40 1,088.00 L3/` DS� p ���GQR� `'" O� H E RRO N� Enterprises USA, Inc. PhFax (303) 763 9686 t�� E-Mail Lennie.Herron�comcast.net � Hazardous Materials'Mold'Asbestos•Lead Paint Website www.HERRON-Enterprises.com Environmental Services'Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305 December 15, 2011 Ms. Lauren Smith HERRON� Project No.: 1213114 Job No.: Verbal Location: `Single Family Dwelling', 162 E. Gore Creek Dr., Vail, CO 81657 Date(s) of Service: December 14-15, 2011 Services Requested: Environmental Consultation/Limited Asbestos Building Inspection Per your request, and under the guidelines defined, HERRON� Enterprises USA, Inc. (HERRON�) has concluded the Environmental Consultation/Comprehensive Asbestos Building Inspection at the aforementioned property. Local, state and/or federal regulations, including but not limited to AQCC Regulation 8(State), 29 CFR 1926.1101 (OSHA), 40 CFR Part 61 EPA (NESHAP), and 40 CFR 763 EPA (AHERA) may require a comprehensive asbestos inspection prior to a renovation or demolition. This inspection requires an AHERA and State certified asbestos building inspector identifying and sampling any friable and non-friable asbestos containing materials which could be affected by the activity. HERRON� was contracted by the Client, to perform: `Single Family Dwelling', 162 E. Gore Creek Dr., Vail, CO 81657 a. Limited Asbestos Building Inspection prior to a renovation is intended to confirm Environmental Hazards, specifically Asbestos-Containing Materials; i. Limited to locations and materials as requested by the Client, only; 1. Comprehensive to Drywall Walls (only) ii. Rush Turnaround PLM Analyses; iii. It was expressly advised that although this is a Limited Asbestos Building Inspection, it is a limited inspection which is designed to indicate the presence of Asbestos Containing Materials in the Building(s), and under normal the guidelines defined, specific samples and locations have been instructed and authorized by the Client. Although some materials may indicate that Asbestos is not present in this report, and under the protocol of limited sampling whereas not `all' suspect materials were sampled, under local, state andlor federal regulations, including but not limited to AQCC Regulation 8 and OSHA 29 CFR 1926.1101, a certain protocol for sampling, number of samples obtained, and assessment is required. HERRON� was subsequently contracted by the Client, to perform: 1. Not applicable HERRONm Project No. 12131 14 Page No. -] December I5, 2011 Limited Asbestos Building Inspection TO�� 75 South Frontage Rd. Vail, Colorado 81657 970-479-213 8/479-213 9 FAX 970-479-2452 December 16, 2011 Lauren Smith, Owner Mountain Cup Cakes PO Box 1589 Eagle, CO 81631 Re: Food Service Plan Review Mountain Cup Cakes 194 E. Gore Creek Dr. Vail, CO 81657 Dear Ms. Smith: Department of Community Development William T. Carlson, REHS Environmental Health Officer This letter will serve to confirm the plan review of the above captioned food service establishment plans. The plans have been approved with the following additions and/or modifications: The hot water generation required for this bakery is 84,909 BTU's per hour. Provide a statement from the designing engineer that the building common domestic water heating plant has adequate capacity to provide the required hot water for this bakery. Retail food establishments with no space on the premises for consumption of food by patrons are required to provide toilet facilities only for employees. Separate toilet facilities are not required for each sex for 15 or fewer employees where there is no seating capacity; provided the toilet is a single occupancy facility and the door can be secured from the inside. The toilet facility shall comply with the requirements of the Plumbing Code of the Town of Vail. Public toilets in the building area may suffice for the use of retail food establishment patrons and employees, if toilets are provided in adequate numbers conveniently located to the retail food establishment and available at all times the food establishment is in operation. Properly seal sinks and drain boards to their adjacent wall. Exposed screw heads and bolts are not approved. The countertop convection oven is acceptable for baking cookies and/or other bakery products. The minimum acceptable ceiling finish in the food preparation area is gloss enamel or epoxy-based paint on drywall; or a non-perforated vinyl-coated lay-in ceiling tile. � • The minimum acceptable wall finish in a food preparation and storage area is a smooth, easily cleanable, light in color non-toxic gloss enamel or an epoxy-based paint. • Under counter surfaces must be finished and sealed to provide a washable surface. • The junctures between walls and floors shall be coved and sealed. • Light fixtures must be adequately enclosed or shielded to protect foods in the storage, serving, or preparation areas from accidental bulb or tube breakage. • All exposed food placed out for serving shall be adequately covered or protected with approved sneeze guards. • Under counter surfaces must be finished and sealed to provide a washable surface. • Garbage and refuse containers, dumpsters, and compactor systems located outside, shall be stored on a smooth surface of nonabsorbent material, such as concrete or machine-laid asphalt, that is kept clean and maintained in good repair. • All equipment must be National Sanitation Foundation (NSF) listed or equivalent. Equipment cut sheets have not yet been provided or received. Approval of these plans and specifications does not constitute endorsement or acceptance of the completed establishment (structure or equipment). A final inspection is required to deternune if the kitchen is in compliance with the Colorado Retail Food Rules and Regulations. Arrangements for this inspection will be made not less than seven (7) days prior to your anticipated opening. Do not hesitate to call me at 970-479-2333 if you have any questions. V ery truly yours, William T. Carlson, REHS Environmental Health Officer Cc: TOV Building Dept. Jeffery Manley, AIA � ����� ERR� � H E RRO N� Enterprises USA, Inc. PhFax (303) 763 9686 t,�,`, _ �, E-Mail Lennie.Herron@comcast.net '��IFsh6d� Hazardous Materials'Mold*Asbestos"Lead Paint Website www.HERRON-Enterprises.com EnvironmenWl Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305 Thank you for the opportunity to be of service. Should you have any questions or comments regarding this report, please do not hesitate to call HERRON� Enterprises USA, Inc. Sincerely, Sincerely, Billie J. Henon-Lusk Project Manager I-IERRON� Enterprises USA, Inc. Certified Asbestos Building Inspector(s): Serina A. Schenker Assumptions, and Limitations This Environmental Consultation is applicable in whole, not in part, to the entire contents of the document. HERRON� and this Environmental Consultation make no representation or assumptions as to past and/or future conditions/occurrences of the specific area(s) inspected. The results, conclusions and/or recommendations expressed in this Environmental Consultation are based solely on the conditions which were observed at the time of this Environmental Consultation. HERRON�'s inspection incorporated non-destructive sampling techniques and visual inspections in areas which were visible/accessible. Conditions and/or materials which were not inspected and/or commented on may very well differ from those which were inspected and/or commented on. HERRON� selected sample locations and frequency of sampling based on observations, your requirements and/or the assumption that like materials in the same area are homogeneous. HERRON� has specifically designed this Environmental Consultation for Client use in the location and identity of Asbestos Containing Material (AC1Vn, and under no circumstances is this Environmental Consultation to be copied, used as a bidding tool and/or used for the development of an Asbestos Abatement Specification document without the express written permission of an executive officer of HERRON�. HERRON� is not responsible/liable for any opinions, conclusions and/or recommendations as provided by others based on any means presented in this Environmental Consultation. With use of Environmental Consultation, and/or use of any services offered by HERRON�, Client(s) agrees that HERRON� has been given the authority by the Owner(s) of a property to enter the aforementioned premises, perform the services, utilize any and all floor plans, blue prints, etc., and agrees to indemnify, hold harmless, and defend HERRON�, its Officers, Employees, Assigns, etc. for any and all claims, costs or damages that may result from services contracted, etc. HERRON° Project No. 1213114 Page No. - 2 December 15, 2011 Limited Asbestos Building Inspection ���� � G'" 0� H E RRO N� Phone (303) 763 9639 Enterprises USA, Inc. Fax (303) 763 9686 ��, E-Mail Lennie.Herron@comcastnet � Hazardous Materials'Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com Environmental Services'Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305 Recommendations The Client has advised that Drywall Walls (only), `Single Family Dwelling', 162 E. Gore Creek Dr., Vail, CO 81657 is a renovation. As Regulated Asbestos Containing Materials were not discovered during this inspection, further action is not required. Conclusion Based on the information generated by this report, we conclude that the aforementioned property does not contain Regulated Asbestos Containing Material(s) (RACM) in the locations inspected for purposes of a renovation. In order to comply with local, state, and/or federal regulations, the following RACM, or assumed RACM will have to be removed if they will be affected by the renovation or demolition: None detected. Although a material may have been determined to contain <=1.0% Asbestos, such as the composition of drywall/joint compound (when the joint compound does not cover the entire surface), traces of asbestos in surfacing materials, thermal system insulation materials, or miscellaneous materials, etc, which is not considered Regulated Asbestos Containing Materials by NESHAPS, EPA (AHERA), or the State of Colorado, may still be regulated by OSHA. OSHA regulations may apply during potential disturbance activities, and the inspection document will serve as a Hazard Communication and should be reviewed during an activity such as a renovation or demolition, to ensure that an exposure does not occur. The Ma�cimum Allowable Asbestos Level (MAAL) may not be exceeded at `any' time in accordance with local, state, and/or federal regulations, including but not limited to AQCC Regulation 8(State), 29 CFR 1926.1101 (OSHA), 40 CFR Part 61 EPA (NESHAP), and 40 CFR 763 EPA (AHERA). This document serves as a certified notification to the owner/operator of the facility and the demolition contractor that any asbestos-containing material allowed to stay in the facility must remain non-friable during demolition. All building material field information concerning sampling protocols, locations, assessments, etc. is available in our files for Client use should the need arise. Suspect materials which were sampled and determined to contain r-1.0% Asbestos (refer to Attachments), by PLM and/or PLM Point Count analysis are: Beige Drywall Walls (only) Materials specific to the renovation as directed by the Client, Surfacing Material (S), Non-Friable, <5,000 ft2, Good Condition Current Condition), 3 Sample(s), 121411-1A, ls` Floor Closet, NW Corner, 3.5' from Floor 121411-1B, ls` Floor Closet, at N Wall, 2' from E Wall, 3.5' from Floor 121411-1C, Stage in Front Room, at N Stage Wall, 6' from W Wall, 1' from Floor Suspect materials which were not within the Scope of Work at the time of the inspection were: l. `All' EPA suspect Materials not requested. 2. `Any' confirmed or suspect ACM which may have been concealed at the time of the inspection. 3. During a normal inspection, and more specifically when non-destructive sampling techniques are employed, it is not within the scope of the inspection to remove surface materials to inspect the structures and/or materials which may HERRONm Project No. 1213114 Page No. - 3 December 15, 2011 Limited Asbestos Building Inspection ����� ERR� � H E RRO N� Enterprises USA, Inc. PhFax (303) 763 9686 �� E-Mail Lennie.Herron�comcast.net � Hazardous Materials'Mold'Asbestos*Lead Paint Website www.HERRON-Enterprises.com Environmental Services'Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305 be under the surface, i.e., within or under concealed areas such as under carpet, under sub-floors, within chases, walls, crawlspaces, tunnels, etc., to remove suspect Asbestos Containing Material(s), to move and/or sample electrical wiring which has not been 'locked ouY, etc. All said areas are to be assumed as containing > 1.0% Asbestos, until such a time that these areas are made accessible, and/or rendered safe so that sampling can be performed. 4. HERRON� recommends extreme caution during a renovation or demolition of these areas in the event that an area which was not suspect, visible, accessible and/or specified during the inspection, is discovered to contain or is suspected of containing an Asbestos Containing Material (ACM). Under local, state and/or federal regulations, should such an event occur, the Client and or Contractor is required to cease operations which may effect this (these) material(s) until an inspection is concluded and a determination is made by an AHERA and State Certified Asbestos Building Inspector. 5. It was expressly advised that although this is a Limited Asbestos Building Inspection, it is comprehensive to the aforementioned materials. Only materials impacted requiring response actions have been instructed and authorized by the Client. Under the protocol of limited sampling whereas not `all' suspect materials outside of the response action areas were sampled, under local, state and/or federal regulations, including but not limited to AQCC Regulation 8 and OSHA 29 CFR 1926.1101, a certain protocol for sampling, number of samples obtained, and assessment is required. 6. Disturbance of these areas could create a potential health hazard. Suspect materials which were visually inspected and determined to be Non-ACM materials at the time of the inspection were: Fiberglass Wood Glass Metal Plastic Concrete Etc. Inspection Methodology: HERRON� selected sample locations and frequency of sampling based on observations, Client requirements and/or the assumption that like materials in the same area are homogeneous in accordance with EPA Publication EPA 560 / 5-85 - 030a `Asbestos in Buildings: Simplified Sampling Scheme'. Sample locations and frequency of sampling of Walls and Ceilings are based on EPA 9/30/94 EPA Sampling Bulletin - ASBESTOS SAMPLING BLJI,LETIN September 30, 1994 - Supplementary Guidance on Bulk Sample Collection and Analysis. Section V of this guidance bulletin offers a suggested strategy for distinguishing between joint compound found at joints in wallboard systems or when the material was applied as a skim coat; i.e., for determining whether "joint compound" has been applied as a"skim coat" over a wall surface (as referred to in the NESHAP Jan. 5, 1994 FR notice.). HERRONm Project No. 12131 14 Page No. - 4 December 15, 2011 Limited Asbestos Building Inspection ������ ERR� � H E RRO N� Enterprises USA, Inc. PhFax (303) 763 9686 c�� E-Mail Lennie.Herron@comcast.net � Hazardous Materials'Mold*Asbestos•Lead Paint Website www.HERRON-Enterprfses.com Environmental Services•Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Coloredo 80227-5305 � . � :� 4�,e�*•- �r � �. ' ,:r , 3 ' � �', �t � � � . . � � M�;� uj- . '� F; - lA � � a�+��� �� . ..�; � � ,.,: � � ta�":�� � u��w J E � •�� a �,�.� . s�.--..n... q ��u I. I: 1� HERRONo Project No. 1213114 Page No. - 5 December 15, 2011 Limited Asbestos Building Inspection R E 1 LA B Reservoirs En vironm�en ta/, December 14, 2011 Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 226073-1 Project # / P.O. # 1213114 Project Description: None Given Lennie Herron Herron Enterprises, USA, Inc. 7261 W. Hampden Ave. Lakewood CO 80227 Dear Customer, //7C. Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 226073-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, _ � -- _ , ,-- - _� -- -.- '' � ✓ �- � . --� :�---.--s_-�_�_ s—_ <_ : _ - Jeanne Spencer Orr President ; ? � , �'-`� - %�i �u� �- � � � Analyst(s): � �� Paul D. LoScalzo Wenlong Liu Michael Scales Adam Humphreys Anita Grigg Robert R. Workman Jr. Bethany Nichols Anya Angst P:303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 of 2 1-866-RESI-ENV www.reilab.com RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O. Client Project Description: Date Samples Received: Analysis Type: Turnaround: Date Analyzed: RES 226073-1 Herron Enterprises, USA, Inc. 1213114 None Given December 14, 2011 PLM, Short Report 2 Hour December 14, 2011 Page 2 of 2 ien a L Asbestos Content on on- Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part � Fibrous Component E Description (%) Mineral � visuai omponents (%) R ; Estimate (% % 121411-1A EM 837266 A Beige paint 1 ND 0 100 B White tape 5 ND 95 5 C White compound 5 ND 0 100 D White/brown drywall 89 ND 15 85 121411-16 EM 837267 A White/brown drywall w/ beige paint 100 ND 15 85 121411-1C EM 837268 A Beige paint w/ white compound 2 ND 0 100 B White/brown drywall 98 ND 15 85 ND=None Detected TR=Trace, <1% Visual Estimate Trem-Act=Tremoli[e-Actinolite Note: Further analysis by TEM is recommended for organically bound ma[erial (i.e. floor lile) if PLM resul�s are<I%. Data QA Due Date: t�' i''�'f � Due Time: Z�-� •r ve. �� ��� �'B �L�S�,rViQJ',rS ,�/7VfI'"'QJ7fTl�l1 �."r3.�� �,ilSC_ � 6801 Lopon Sl. Danvar. Cp 80216 � Ph: 909 864-1 BBB • Fex 303-477�d275 • To1 Free :886 RESI-ENV PRger:303-609-2098 INVOICE TO: (iF DIFFERENTj _ � CONTACT INFORMATION: CeYpaper. flRal PBta DBiVefalNe Ema9 MtlRSS: HF.ILRON Group RES 226073 -Pege 1 �-^ of �__ nm STOS U►80 O Y:HOURS: Weekda's: 7am -•7 m �', " ' � REQUES7EU ANALYSIS -: .:. <. : ' VAUD MATRIX CODES ` LAB PLlIA f CM! TEM USH (Sarrk Day) _ PRIORITY (Next pay) _STANDARD Air = A 8ulk = B (Ruah PCM a 2hr, TEM = 6hr.) Dust d D Pairrt = P ¢HEMISTRYi'ABORATORY HOURS:; weekdays: ; 8am -'5 m. Soil = S Wfpe = W Metal(s) I Dust _ RUSH _ 24 hr. _,3-5 Day Swab = SW F= Food RCRA 6! bletals & Welding "Prlor notlflcetlon is � RUSH _ 5 day _10 day roqWred ror RUSN � o � Drinking Water = DW Waste Water =1MN Fume Scan ! TCLP — � + ^ a � �{ 0 = Other hansrounde" c� � � v� y OrganiC6 . _ 24 hf. _ 3 dAy _5 D8y $ o au � � o = °AS7M E1792 epproveC wipe media only• MICROBIOLOGY,L•ABORATORY�HOURS::Vlleekda s: ..9am=6 m 1:; .. y� � �� o� w E.coli 0167:M, Coliforths, S.aureus 24 hr. _2 D 3-5 Da � m �� � Salmonella, LlsteWa, E.cofl, APC, Y 8, M 48 Hr. 3-5 D T y "��° �' � ������� eY '_ o $ � , � g°a �Do Mold ,_,_ R USH �24 Hr ^48 Hf _3 Day _5 Qey ��� g� ;� + ; a g� o c h ffi � � g E °TUm�round Umaa entabliah e laboratory priorfiy, dubJed to laboratory wiurne and are not puarantuad.�Additbnal fcso �. � 2, �+� ��+ �� ,. , , -:� ;. . , ' 't apply (or atterhouo wsekontls and hdida c.« `+ � . r � � f d � � � ; + � ' ? Special lnstructions: � � <. � � � � a h + � CSV FII;E REQUIRED ' W ' ~ � � � E g � �p � � � � a � � �' a � ui .7 Q ui c.ai vi } g a CIIBOt`Sahl Ie ID .OUt[Ib@G .•<: •,;', $ample 1D s,must tie unl ue)- :� r' � w� �' Q t� o a�uCttoe�o�ocv va, � i�.i�.l+l_te� � � �� �C � ,, -. -� . . .. . .; � , : ;. ._ _ �:� � , . . . , � �o : Number of samples received: NOTE REI w� antlyse t�wrNnq tartpbs enafysfs ae ind{rated on We Cheln oi Cus� 0 m � � � '_ o v m m � v° � EM Number(�aboralo� �Q � Date Time Uae Oriy) W � Colledad Collected fn c�. � qp mnMtlyy hh/mm a!p � �' 3�ti.c..� co -�+ �S f �: . I ;: ° . � - I,�;. _. , � ' �� . , , , , � � .. , .,. (Additional samples shail be listed on aHeched [ong form.} �a ' ed andyAl na be rcepondble for anors or orNubns in wleula8ona rewlG�p fiom tlrc inscarraay of aylnal tl�ta. By dpninq epsnUCOmparry reproeenmtive e0rces Uat subrtis�fon of Ihe fdbNinp cemples for requealed dy nsUluls an � 'cal serGfces agreement wtM peyrnent tefmn ot NET 30 days, fa0ure b comply Nilh peymenl tertna mey reauft in a 1.5% rcanlNy 4�(erest aurc.t�arge. �� - 1 Dele/Time: • L I• � Sample Condition: an Ice Sealed ct � �atemme: i'z ' ��'l ' I I Came {�~ r Temp. (F°) Yes / No Yes / No �/ No Ph e Fax Date Time InlNals Contaa Phon Emai Fax Date Tima IniUals Phone EmaU Fax Date Time tnitials Contact __ Phone Fax Dete Time InHials 7-201 i version 1 . . —. . _... �::_��: F4•�&•�f: �'� �"�4¢'e,'i��°tsd.C�`$ ��,� �;�� 0 0 i �.°`o �\ oi l y� � ,.: :. , ,.� �: �� ;�'O STATE �F COL�RADO ; ��y� �.. F � ... Co1Q�-a'c s i; ` . � '��� ��� � ��� , .,. � { �' �� i �' v�t �• ,��� �����.� ���t, - �. . ,� � - +z,, � �. � � �` � � t�:;� ; �� � .. �x ��`ii,. J � `, ��e' `' ' :'!'�1.�' : A F ;: w ,� _ � y ., t���y� 1� 5-a�u ;._ ' ,,. ;. '': has met th�:xec '�ommissioi�l Tssued: 10/1 ��`�FI�A�IQ�� �3� �liih �.�. fr.�- !k {' � ... `� � tr � Depa.r�� of Public'��e� �.... ���', �������t - .. ..: ...,n,. . y,.. . �. .:,.�:'=w . . . _ ..., .... � .� �u� �er��fi�s tl�at r t�': ��IIa x�����l��Y' —� �---' i2r� .i ii �.t� .Jinc �. .i,r.�r.z a k'�da�:?i-s lk �:;-, i �tifica��"on t�a; 15`7�,73 F�" 0 olor� in t%e fo1lo�Yir � _' �{" .�'�=BUI��In�'rc����i=Sr .�-_:L 4" .0 . _ ; y, �/+ ::`' �. . �x�:�fvii�. �S' �Zd�'� , � �, � � r ;�1:..`�_ ty 1 u� � Ir1�F r� �' r KY w'�• � ' � .v .'?,4"` �� _�k r. � �� _'.5-r, ��'"h ��� � � � 1 . �..•. ,s`. � 1 f '�1 . � !�a �eii �� v.1 r � 4 .. '� �,C�l�'a" 4 , ,. � y .� ' � _ � �,r � �� : ,� �•��, ST�`'6 Jr x8 +�i ;1� t $ fi3!��r�j;'. � C�tI�.P! �ir +���lity �oi r. �y c��'rtified by . .:k�� « r,�;F � , � r.�::..; y� .._. ...,;;:, .�rb,th-- �;r _ - •;,} �, r - rtL ... . . _� �u�l 4 ..- es on: 10/14/2U12 � "' . . - f� � �... . - �„"v ..._..� ' fy thorized APCD RepresentatNe / bis cert�cale is valid only with the possesslon of a current Dtvislon-approred tralning coarse Yficatton in the dlsclpline specl�Jed a6ove. y�:LL��;a,:�" r�`„°, /..�. ;�; � �y. t ..` 'i �►�x sp f % f� �; ��'; g�6 {� / :-�� ����; �s�+ �ro f Y f E `-�m � :� �°v ^i , a ��y ,� ��k,,'1 b r� �_ ' � m � •r�\ �± ' b� fi �~ i I �o p� . �8 y '4 + ,"„'�, ` T$ro� 'i �` ` � ��: `ti �m;fr ; . ae�. E".k �O �� ✓ (: a e'� • � =' � w� i�`1 . � �4�. 01-11-2013 A . i 7 ...., Inspection Request Re�orting va�i �n _ ��+., n c Requested Inspect Date: Monday January 14, 2013 Site Address: 160 GO�tE CREEK DR VAIL LODGE AT VAIL COMMERICAL SPACE Page 9 A/P/D Information Activity: B11-0510 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type: Occu ancy: Use: M Insp Area: Contractor: SRE BUILDING ASSOCIA�ES Phone: 970-945-6359 Owner: MOUNTAIN WOLF PROPERTIES LLC Description: TENANT IMPROVEMENT REMODEL RETAIL INTO BAKERY (MOUNTAIN CUPCAKE) Reauested Ins�ection(s) Rem: 90 BLDG-Final Requestor: SRE BUIL G ASSOCIATES Comments: follo u Assigned To: S Action: Time Exp: Comment: ir i n o Ne sign over door " To ramain open while occupied" Comment: Ne ire to sign off Ins�ection Historv Item: 120 ELEC-Rough 05/16/12 Inspector: Comment: Item: 200 MECH-Rou h 05/09/1 � Inspector: Comment: ftem: 230 PLMB-Rough/Water 05/14/1 Z Inspector: Comment: ftem: 240 PLMB-Gas Piping 05/30/12 Inspector: Comment: NA Item: 260 PLMB-Misc. 05/30/12 Inspector: Comment:, NA Item: 310 MECH-Heatmg 05/30/12 fnspector: Comment: NA Item: 320 MECH-Exhaust Hoods 05/30/12 Inspector: Comment: ttem: 330 MECH-Suppfy Air 05/30/i2 Inspector: Comment: NA Item: 340 MECH-Misc. 05/30/12 Inspector: Comment: NA Item: 30 BLDG-Framing 05/17/12 Inspector: Comment: ttem: 50 BLDG-Insulation 05/18/12 Inspector: Comment: ftem: 60 BLDG-Sheetrock Nail 05/18/12 Inspector: Comment: ftem: 190 ELEC-Final 05/30/12 Inspector: *" Approved " sgremmer •• Approved " sgremmer " Approved " sgremmer " Approved " sgremmer •« qPProved «• sgremmer " Approved " sgremmer *' Approved *' sgremmer " Approved " sgremmer " Approved "' sgremmer " Approved '" sgremmer JRIVi roved " JRM PProved " " Approved " sgremmer Requested Time: 02:00 PM Phone: 970-390-5776 Entered By: JMONDRAGON K Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED REPT131 Run Id: 14637