HomeMy WebLinkAboutB11-0510NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
_ ,.
1!1�' OF YAii,,_•
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2133, f. 970.4792452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Perrr�it #: B11-0510
Project #: PRJ11-0725
Job Address: 160 GORE CREEK DR VAIL Applied.....: 12/15/2011
Location......: LODGE AT VAIL COMMERICAL SPACE Issued. ..: 04/17/2012
Parcel No....: 2101082?_1004
CONTRACTOR SRE BUILDING ASSOCIATES 04/12/2012 Phone: 970-945-6359
PO BOX 6376
VAIL
CO 81658
License: C000003460
OWNER MOUNTAIN WOLF PROPERTIES LLC 12/15/2011
6532 VIA ROSA
BOCA RATON
FL 33433
Description:
TENANT IMPROVEMENT REMODEL RETAIL INTO BAKERY (MOUNTAIN
CUPCAKE)
Occupancy: M Type Construction: IIB Valuation: $80,000.00
....z�......�.,�......�,.........<.,....,,,....x.>...x.»......,,..>..>.....,,... . FEE SUMMARY ................x...................�.�,.�......�............,.,.,.,,..xx,......
Building Permit -----------> $853.75 Bldg Plan Check ----------> $554.94 Use Tax Fee-----------------------> $1,400.00
Electrical Permit ---------> $690.00 Elec Plan Check -----------> $448.50 Restuarant Plan Review--------> $0.00
Mechanical Permit ------> $400.00 Mech Plan Check ---------> $100.00 Additional Fees--------------------> $75.00
Plumbing Permit --------> $300.00 Pimb Plan Check ---------> $75.00 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $20.00
TOTAL PERMIT FEES--------------> $4,917.19
Payments-------------------------------> $4,917.19
BALANCE DUE------------------------> $0.00
..............x.............xxxx.........x.z�.........z......,.,...�.......,.......,......«.............,,.........,.......,,.......,<...,,,..........xxxx...,..,,.�.�...,....,...,,...,.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
R�QUESTS FOR INSP CTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8: 0 AM - 4:00 PM.
1�� ���
Signature of Owner or Contractor Date
�v.c� S hn.� U�.
Print Name
combination permit_012811
,�,ri.»..» ..............�....�......,,,,,.x.x.x„>,,,x..,x...............,.,,........,...�,,...x,,,x,,..,.,..x...,,,.,..«..,,.,..,,..,,,...�.,.......,.,,..x.�,.>,...�»�......,.,,�...
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit#: 611-0510 A�dress: 16Q GORE CREEK �R VAIL
Owner: MOUNTAIN WOLF PROPERTIES LLC Location:
LODGE AT VAIL COMMERICAL SPACE
.,,�......<,.<x�>,.,>..,�,x,.,,....,.,>,....,..,,.,�...........� ...................«„>,...,.......,».,.,....,.,�,�,..�..,........,,........,,.,....,.�..............,.,...........
Cond: CON0012390
Rock resorts/Lodge at Vail has been advised that completion
of sprinkler retrofit order is required. This is not a
condition of approval for the applicant, however, the
landlord is expected to complete sprinkler layout.
combination permit_012811
********************************************************************************************
TOWN �F VAIL, CC�L��RAL'O Statemer.t
********************************************************************************************
Statement Number: R120000290 Amount: $3,000.00 04/17/201203:31 PM
Payment Method:Credit Crd Init: SAB
Notation: MC-LAUREN
SMITH
-----------------------------------------------------------------------------
Permit No: B11-0510 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-082-2100-4
Site Address: 160 GORE CREEK DR VAIL
Location: LODGE AT VAIL COMMERICAL SPACE
Total Fees: $4,917.19
This Payment: $3,000.00 Total ALL Pmts: $3,829.19
Balance: $1,088.00
**************************************�*****************************+********++*************
ACCOUNT ITEM LIST:
Account Code
BP 00100003111100
EP 00100003111100
MP 00100003111100
PF 00100003112300
PP 00100003111100
UT 11000003106000
WC 00100003112800
Descriptiori
BUILDING PERMIT FEES
ELECTRICAL PERMIT FEES
MECHANICAL PERMIT FEES
PLAN CHECK FEES
PLUMBING PERMIT FEES
USE TAX 4%
WILL CALL INSPECTION FEE
Current Pmts
829.50
690.00
400.00
948.50
300.00
312.00
20.00
***************************************************+**+************�*��***************�*****
TOWN OF VAIL, COLORADO Statement
*************************************************�****�*************************************
Statement Number: R120000289 Amount: $24.25 04/17/201203:30 PM
Payment Method: Cash Init: SAB
Notation: CASH-LAUREN
SMITH
-----------------------------------------------------------------------------
Permit No: B11-0510 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-082-2100-4
Site Address: 160 GORE CREEK DR VAIL
Location: LODGE AT VAIL COMMERICAL SP�CE
Total Fees: $4,917.19
This Payment: $24.25 Total ALL Pmts: $829.19
Balance: $4,088.00
*********************************�*******++***************+*********************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 24.25
****************************+***************************************************************
TOWN OF VAIL, COLORADO Statement
********�**************************************�**************************+*****************
Statement Nnmber.: �17_OOOC291_ Amc>;nt: $?,088.00 09/1?/2012.03:32 pM
Payment Method:Credit Crd Init: SAB
Notation: VISA-LAUREN
SMITH
-----------------------------------------------------------------------------
Permit No: B11-0510 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-082-2100-4
Site Address: 160 GORE CREEK DR VAIL
Location: LODGE AT VAIL COMMERICAL SPACE
Total Fees: $4,917.19
This Payment: $1,088.00 Total ALL Pmts: $4,917.19
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
DT 11000003106000 USE TAX 40 1,088.00
L3/` DS� p
���GQR�
`'" O� H E RRO N� Enterprises USA, Inc. PhFax (303) 763 9686
t�� E-Mail Lennie.Herron�comcast.net
� Hazardous Materials'Mold'Asbestos•Lead Paint Website www.HERRON-Enterprises.com
Environmental Services'Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
December 15, 2011
Ms. Lauren Smith
HERRON� Project No.: 1213114
Job No.: Verbal
Location: `Single Family Dwelling', 162 E. Gore Creek Dr., Vail, CO 81657
Date(s) of Service: December 14-15, 2011
Services Requested: Environmental Consultation/Limited Asbestos Building Inspection
Per your request, and under the guidelines defined, HERRON� Enterprises USA, Inc. (HERRON�) has concluded the
Environmental Consultation/Comprehensive Asbestos Building Inspection at the aforementioned property.
Local, state and/or federal regulations, including but not limited to AQCC Regulation 8(State), 29 CFR 1926.1101
(OSHA), 40 CFR Part 61 EPA (NESHAP), and 40 CFR 763 EPA (AHERA) may require a comprehensive asbestos
inspection prior to a renovation or demolition. This inspection requires an AHERA and State certified asbestos building
inspector identifying and sampling any friable and non-friable asbestos containing materials which could be affected by the
activity.
HERRON� was contracted by the Client, to perform:
`Single Family Dwelling', 162 E. Gore Creek Dr., Vail, CO 81657
a. Limited Asbestos Building Inspection prior to a renovation is intended to confirm Environmental Hazards,
specifically Asbestos-Containing Materials;
i. Limited to locations and materials as requested by the Client, only;
1. Comprehensive to Drywall Walls (only)
ii. Rush Turnaround PLM Analyses;
iii. It was expressly advised that although this is a Limited Asbestos Building Inspection, it is a
limited inspection which is designed to indicate the presence of Asbestos Containing Materials in
the Building(s), and under normal the guidelines defined, specific samples and locations have
been instructed and authorized by the Client. Although some materials may indicate that
Asbestos is not present in this report, and under the protocol of limited sampling whereas not
`all' suspect materials were sampled, under local, state andlor federal regulations, including but
not limited to AQCC Regulation 8 and OSHA 29 CFR 1926.1101, a certain protocol for
sampling, number of samples obtained, and assessment is required.
HERRON� was subsequently contracted by the Client, to perform:
1. Not applicable
HERRONm Project No. 12131 14 Page No. -] December I5, 2011
Limited Asbestos Building Inspection
TO��
75 South Frontage Rd.
Vail, Colorado 81657
970-479-213 8/479-213 9
FAX 970-479-2452
December 16, 2011
Lauren Smith, Owner
Mountain Cup Cakes
PO Box 1589
Eagle, CO 81631
Re: Food Service Plan Review
Mountain Cup Cakes
194 E. Gore Creek Dr.
Vail, CO 81657
Dear Ms. Smith:
Department of Community Development
William T. Carlson, REHS
Environmental Health Officer
This letter will serve to confirm the plan review of the above captioned food service
establishment plans. The plans have been approved with the following additions and/or
modifications:
The hot water generation required for this bakery is 84,909 BTU's per hour. Provide a
statement from the designing engineer that the building common domestic water heating
plant has adequate capacity to provide the required hot water for this bakery.
Retail food establishments with no space on the premises for consumption of food by
patrons are required to provide toilet facilities only for employees. Separate toilet
facilities are not required for each sex for 15 or fewer employees where there is no
seating capacity; provided the toilet is a single occupancy facility and the door can be
secured from the inside. The toilet facility shall comply with the requirements of the
Plumbing Code of the Town of Vail. Public toilets in the building area may suffice for
the use of retail food establishment patrons and employees, if toilets are provided in
adequate numbers conveniently located to the retail food establishment and available at
all times the food establishment is in operation.
Properly seal sinks and drain boards to their adjacent wall. Exposed screw heads and
bolts are not approved.
The countertop convection oven is acceptable for baking cookies and/or other bakery
products.
The minimum acceptable ceiling finish in the food preparation area is gloss enamel or
epoxy-based paint on drywall; or a non-perforated vinyl-coated lay-in ceiling tile.
�
• The minimum acceptable wall finish in a food preparation and storage area is a smooth,
easily cleanable, light in color non-toxic gloss enamel or an epoxy-based paint.
• Under counter surfaces must be finished and sealed to provide a washable surface.
• The junctures between walls and floors shall be coved and sealed.
• Light fixtures must be adequately enclosed or shielded to protect foods in the storage,
serving, or preparation areas from accidental bulb or tube breakage.
• All exposed food placed out for serving shall be adequately covered or protected with
approved sneeze guards.
• Under counter surfaces must be finished and sealed to provide a washable surface.
• Garbage and refuse containers, dumpsters, and compactor systems located outside, shall
be stored on a smooth surface of nonabsorbent material, such as concrete or machine-laid
asphalt, that is kept clean and maintained in good repair.
• All equipment must be National Sanitation Foundation (NSF) listed or equivalent.
Equipment cut sheets have not yet been provided or received.
Approval of these plans and specifications does not constitute endorsement or acceptance of the
completed establishment (structure or equipment). A final inspection is required to deternune if
the kitchen is in compliance with the Colorado Retail Food Rules and Regulations.
Arrangements for this inspection will be made not less than seven (7) days prior to your
anticipated opening.
Do not hesitate to call me at 970-479-2333 if you have any questions.
V ery truly yours,
William T. Carlson, REHS
Environmental Health Officer
Cc: TOV Building Dept.
Jeffery Manley, AIA
�
�����
ERR� � H E RRO N� Enterprises USA, Inc. PhFax (303) 763 9686
t,�,`, _ �, E-Mail Lennie.Herron@comcast.net
'��IFsh6d� Hazardous Materials'Mold*Asbestos"Lead Paint Website www.HERRON-Enterprises.com
EnvironmenWl Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
Thank you for the opportunity to be of service. Should you have any questions or comments regarding this report, please do
not hesitate to call HERRON� Enterprises USA, Inc.
Sincerely,
Sincerely,
Billie J. Henon-Lusk
Project Manager
I-IERRON� Enterprises USA, Inc.
Certified Asbestos Building Inspector(s): Serina A. Schenker
Assumptions, and Limitations
This Environmental Consultation is applicable in whole, not in part, to the entire contents of the document.
HERRON� and this Environmental Consultation make no representation or assumptions as to past and/or future
conditions/occurrences of the specific area(s) inspected.
The results, conclusions and/or recommendations expressed in this Environmental Consultation are based solely on the
conditions which were observed at the time of this Environmental Consultation.
HERRON�'s inspection incorporated non-destructive sampling techniques and visual inspections in areas which were
visible/accessible. Conditions and/or materials which were not inspected and/or commented on may very well differ from
those which were inspected and/or commented on.
HERRON� selected sample locations and frequency of sampling based on observations, your requirements and/or the
assumption that like materials in the same area are homogeneous.
HERRON� has specifically designed this Environmental Consultation for Client use in the location and identity of
Asbestos Containing Material (AC1Vn, and under no circumstances is this Environmental Consultation to be copied,
used as a bidding tool and/or used for the development of an Asbestos Abatement Specification document without the
express written permission of an executive officer of HERRON�.
HERRON� is not responsible/liable for any opinions, conclusions and/or recommendations as provided by others based on
any means presented in this Environmental Consultation.
With use of Environmental Consultation, and/or use of any services offered by HERRON�, Client(s) agrees that HERRON�
has been given the authority by the Owner(s) of a property to enter the aforementioned premises, perform the services, utilize
any and all floor plans, blue prints, etc., and agrees to indemnify, hold harmless, and defend HERRON�, its Officers,
Employees, Assigns, etc. for any and all claims, costs or damages that may result from services contracted, etc.
HERRON° Project No. 1213114 Page No. - 2 December 15, 2011
Limited Asbestos Building Inspection
����
� G'" 0� H E RRO N� Phone (303) 763 9639
Enterprises USA, Inc. Fax (303) 763 9686
��, E-Mail Lennie.Herron@comcastnet
� Hazardous Materials'Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com
Environmental Services'Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
Recommendations
The Client has advised that Drywall Walls (only), `Single Family Dwelling', 162 E. Gore Creek Dr., Vail, CO 81657 is
a renovation.
As Regulated Asbestos Containing Materials were not discovered during this inspection, further action is not required.
Conclusion
Based on the information generated by this report, we conclude that the aforementioned property does not contain Regulated
Asbestos Containing Material(s) (RACM) in the locations inspected for purposes of a renovation.
In order to comply with local, state, and/or federal regulations, the following RACM, or assumed RACM will have to be
removed if they will be affected by the renovation or demolition:
None detected.
Although a material may have been determined to contain <=1.0% Asbestos, such as the composition of drywall/joint
compound (when the joint compound does not cover the entire surface), traces of asbestos in surfacing materials, thermal
system insulation materials, or miscellaneous materials, etc, which is not considered Regulated Asbestos Containing
Materials by NESHAPS, EPA (AHERA), or the State of Colorado, may still be regulated by OSHA. OSHA regulations
may apply during potential disturbance activities, and the inspection document will serve as a Hazard Communication
and should be reviewed during an activity such as a renovation or demolition, to ensure that an exposure does not occur.
The Ma�cimum Allowable Asbestos Level (MAAL) may not be exceeded at `any' time in accordance with local, state,
and/or federal regulations, including but not limited to AQCC Regulation 8(State), 29 CFR 1926.1101 (OSHA), 40 CFR
Part 61 EPA (NESHAP), and 40 CFR 763 EPA (AHERA).
This document serves as a certified notification to the owner/operator of the facility and the demolition contractor that any
asbestos-containing material allowed to stay in the facility must remain non-friable during demolition.
All building material field information concerning sampling protocols, locations, assessments, etc. is available in our files for
Client use should the need arise.
Suspect materials which were sampled and determined to contain r-1.0% Asbestos (refer to Attachments), by PLM and/or
PLM Point Count analysis are:
Beige Drywall Walls (only) Materials specific to the renovation as directed by the Client, Surfacing Material (S),
Non-Friable, <5,000 ft2, Good Condition Current Condition), 3 Sample(s),
121411-1A, ls` Floor Closet, NW Corner, 3.5' from Floor
121411-1B, ls` Floor Closet, at N Wall, 2' from E Wall, 3.5' from Floor
121411-1C, Stage in Front Room, at N Stage Wall, 6' from W Wall, 1' from Floor
Suspect materials which were not within the Scope of Work at the time of the inspection were:
l. `All' EPA suspect Materials not requested.
2. `Any' confirmed or suspect ACM which may have been concealed at the time of the inspection.
3. During a normal inspection, and more specifically when non-destructive sampling techniques are employed, it is not
within the scope of the inspection to remove surface materials to inspect the structures and/or materials which may
HERRONm Project No. 1213114 Page No. - 3 December 15, 2011
Limited Asbestos Building Inspection
�����
ERR� � H E RRO N� Enterprises USA, Inc. PhFax (303) 763 9686
�� E-Mail Lennie.Herron�comcast.net
� Hazardous Materials'Mold'Asbestos*Lead Paint Website www.HERRON-Enterprises.com
Environmental Services'Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
be under the surface, i.e., within or under concealed areas such as under carpet, under sub-floors, within chases,
walls, crawlspaces, tunnels, etc., to remove suspect Asbestos Containing Material(s), to move and/or sample
electrical wiring which has not been 'locked ouY, etc. All said areas are to be assumed as containing > 1.0%
Asbestos, until such a time that these areas are made accessible, and/or rendered safe so that sampling can be
performed.
4. HERRON� recommends extreme caution during a renovation or demolition of these areas in the event that an area
which was not suspect, visible, accessible and/or specified during the inspection, is discovered to contain or is
suspected of containing an Asbestos Containing Material (ACM). Under local, state and/or federal regulations,
should such an event occur, the Client and or Contractor is required to cease operations which may effect this (these)
material(s) until an inspection is concluded and a determination is made by an AHERA and State Certified Asbestos
Building Inspector.
5. It was expressly advised that although this is a Limited Asbestos Building Inspection, it is comprehensive to the
aforementioned materials. Only materials impacted requiring response actions have been instructed and
authorized by the Client. Under the protocol of limited sampling whereas not `all' suspect materials outside of
the response action areas were sampled, under local, state and/or federal regulations, including but not limited to
AQCC Regulation 8 and OSHA 29 CFR 1926.1101, a certain protocol for sampling, number of samples obtained,
and assessment is required.
6. Disturbance of these areas could create a potential health hazard.
Suspect materials which were visually inspected and determined to be Non-ACM materials at the time of the inspection
were:
Fiberglass
Wood
Glass
Metal
Plastic
Concrete
Etc.
Inspection Methodology:
HERRON� selected sample locations and frequency of sampling based on observations, Client requirements and/or
the assumption that like materials in the same area are homogeneous in accordance with EPA Publication EPA 560 /
5-85 - 030a `Asbestos in Buildings: Simplified Sampling Scheme'.
Sample locations and frequency of sampling of Walls and Ceilings are based on EPA 9/30/94 EPA Sampling Bulletin -
ASBESTOS SAMPLING BLJI,LETIN September 30, 1994 - Supplementary Guidance on Bulk Sample Collection and
Analysis. Section V of this guidance bulletin offers a suggested strategy for distinguishing between joint compound
found at joints in wallboard systems or when the material was applied as a skim coat; i.e., for determining whether "joint
compound" has been applied as a"skim coat" over a wall surface (as referred to in the NESHAP Jan. 5, 1994 FR
notice.).
HERRONm Project No. 12131 14 Page No. - 4 December 15, 2011
Limited Asbestos Building Inspection
������
ERR� � H E RRO N� Enterprises USA, Inc. PhFax (303) 763 9686
c�� E-Mail Lennie.Herron@comcast.net
� Hazardous Materials'Mold*Asbestos•Lead Paint Website www.HERRON-Enterprfses.com
Environmental Services•Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Coloredo 80227-5305
�
. �
:�
4�,e�*•-
�r � �.
' ,:r
, 3 ' � �',
�t � � � .
. � � M�;� uj- . '�
F; -
lA
�
� a�+���
�� . ..�; � � ,.,: �
� ta�":�� � u��w
J E
� •�� a �,�.� . s�.--..n... q ��u I.
I:
1�
HERRONo Project No. 1213114 Page No. - 5 December 15, 2011
Limited Asbestos Building Inspection
R E 1 LA B Reservoirs En vironm�en ta/,
December 14, 2011 Laboratory Code: RES
Subcontract Number: NA
Laboratory Report: RES 226073-1
Project # / P.O. # 1213114
Project Description: None Given
Lennie Herron
Herron Enterprises, USA, Inc.
7261 W. Hampden Ave.
Lakewood CO 80227
Dear Customer,
//7C.
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene
and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab
Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM)
analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate
#480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both
Proficiency Testing and PAT programs respectively.
Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your
request. The analysis has been completed in general accordance with the appropriate methodology as
stated in the attached analysis table. The results have been submitted to your office.
RES 226073-1 is the job number assigned to this study. This report is considered highly confidential
and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study
with personnel other than those of the client. The results described in this report only apply to the samples
analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or
any agency of the U.S. Government. This report shall not be reproduced except in full, without written
approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer
storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
Sincerely,
_ � -- _
, ,-- -
_� -- -.-
'' � ✓ �- �
. --� :�---.--s_-�_�_ s—_
<_ : _ -
Jeanne Spencer Orr
President
; ? � , �'-`� -
%�i �u� �- � � �
Analyst(s): � ��
Paul D. LoScalzo Wenlong Liu
Michael Scales Adam Humphreys
Anita Grigg Robert R. Workman Jr.
Bethany Nichols Anya Angst
P:303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Page 1 of 2
1-866-RESI-ENV
www.reilab.com
RESERVOIRS ENVIRONMENTAL, INC.
NVLAP Lab Code 101896-0
TDH Licensed Laboratory # 30-0136
TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
RES Job Number:
Client:
Client Project Number / P.O.
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Analyzed:
RES 226073-1
Herron Enterprises, USA, Inc.
1213114
None Given
December 14, 2011
PLM, Short Report
2 Hour
December 14, 2011
Page 2 of 2
ien a L Asbestos Content on on-
Sample ID Number A Sub Asbestos Fibrous
Number Y Physical Part � Fibrous Component
E Description (%) Mineral � visuai omponents (%)
R ; Estimate (% %
121411-1A EM 837266 A Beige paint 1 ND 0 100
B White tape 5 ND 95 5
C White compound 5 ND 0 100
D White/brown drywall 89 ND 15 85
121411-16 EM 837267 A White/brown drywall w/ beige paint 100 ND 15 85
121411-1C EM 837268 A Beige paint w/ white compound 2 ND 0 100
B White/brown drywall 98 ND 15 85
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem-Act=Tremoli[e-Actinolite
Note: Further analysis by TEM is recommended for organically bound ma[erial (i.e. floor lile)
if PLM resul�s are<I%.
Data QA
Due Date: t�' i''�'f �
Due Time: Z�-� •r
ve.
��
��� �'B �L�S�,rViQJ',rS ,�/7VfI'"'QJ7fTl�l1 �."r3.�� �,ilSC_
� 6801 Lopon Sl. Danvar. Cp 80216 � Ph: 909 864-1 BBB • Fex 303-477�d275 • To1 Free :886 RESI-ENV
PRger:303-609-2098
INVOICE TO: (iF DIFFERENTj _ � CONTACT INFORMATION:
CeYpaper.
flRal PBta DBiVefalNe Ema9 MtlRSS:
HF.ILRON Group
RES 226073
-Pege 1 �-^ of �__
nm STOS U►80 O Y:HOURS: Weekda's: 7am -•7 m �', " ' � REQUES7EU ANALYSIS -: .:. <. : ' VAUD MATRIX CODES ` LAB
PLlIA f CM! TEM USH (Sarrk Day) _ PRIORITY (Next pay) _STANDARD Air = A 8ulk = B
(Ruah PCM a 2hr, TEM = 6hr.)
Dust d D Pairrt = P
¢HEMISTRYi'ABORATORY HOURS:; weekdays: ; 8am -'5 m. Soil = S Wfpe = W
Metal(s) I Dust _ RUSH _ 24 hr. _,3-5 Day Swab = SW F= Food
RCRA 6! bletals & Welding "Prlor notlflcetlon is �
RUSH _ 5 day _10 day roqWred ror RUSN � o � Drinking Water = DW Waste Water =1MN
Fume Scan ! TCLP — � + ^ a � �{ 0 = Other
hansrounde" c� � � v� y
OrganiC6 . _ 24 hf. _ 3 dAy _5 D8y $ o au � � o = °AS7M E1792 epproveC wipe media only•
MICROBIOLOGY,L•ABORATORY�HOURS::Vlleekda s: ..9am=6 m 1:; .. y� � �� o� w
E.coli 0167:M, Coliforths, S.aureus 24 hr. _2 D 3-5 Da � m �� �
Salmonella, LlsteWa, E.cofl, APC, Y 8, M 48 Hr. 3-5 D T y "��° �' � �������
eY '_ o $ � , � g°a �Do
Mold ,_,_ R USH �24 Hr ^48 Hf _3 Day _5 Qey ��� g� ;� + ; a g� o c h
ffi � � g E
°TUm�round Umaa entabliah e laboratory priorfiy, dubJed to laboratory wiurne and are not puarantuad.�Additbnal fcso �. � 2, �+� ��+ ��
,. , , -:� ;. . , ' 't apply (or atterhouo wsekontls and hdida c.« `+ �
. r � � f d � � � ; + � ' ?
Special lnstructions: � � <. � � � � a h + �
CSV FII;E REQUIRED ' W ' ~ � � � E g � �p � � � � a �
� �' a � ui .7 Q ui c.ai vi } g a
CIIBOt`Sahl Ie ID .OUt[Ib@G .•<: •,;', $ample 1D s,must tie unl ue)- :� r' � w� �' Q t� o a�uCttoe�o�ocv va,
� i�.i�.l+l_te� � �
�� �C �
,, -. -� . . .. .
.; � , : ;.
._ _ �:� � , . . . , �
�o :
Number of samples received:
NOTE REI w� antlyse t�wrNnq tartpbs
enafysfs ae ind{rated on We Cheln oi Cus�
0
m
� � � '_
o v m
m � v° � EM Number(�aboralo�
�Q � Date Time Uae Oriy)
W � Colledad Collected
fn c�. � qp mnMtlyy hh/mm a!p
� �' 3�ti.c..�
co -�+
�S
f �: . I ;: ° .
� - I,�;. _. ,
� ' ��
. , , , , � � .. , .,.
(Additional samples shail be listed on aHeched [ong form.}
�a ' ed andyAl na be rcepondble for anors or orNubns in wleula8ona rewlG�p fiom tlrc inscarraay of aylnal tl�ta. By dpninq epsnUCOmparry reproeenmtive e0rces Uat subrtis�fon of Ihe fdbNinp cemples for requealed
dy nsUluls an � 'cal serGfces agreement wtM peyrnent tefmn ot NET 30 days, fa0ure b comply Nilh peymenl tertna mey reauft in a 1.5% rcanlNy 4�(erest aurc.t�arge.
�� - 1
Dele/Time: • L I• � Sample Condition: an Ice Sealed ct
� �atemme: i'z ' ��'l ' I I Came {�~ r Temp. (F°) Yes / No Yes / No �/ No
Ph e Fax Date Time InlNals Contaa Phon Emai Fax Date Tima IniUals
Phone EmaU Fax Date Time tnitials Contact __ Phone Fax Dete Time InHials
7-201 i version 1
. . —. . _... �::_��:
F4•�&•�f: �'� �"�4¢'e,'i��°tsd.C�`$ ��,�
�;��
0
0
i �.°`o
�\ oi
l y�
�
,.:
:.
, ,.�
�:
��
;�'O
STATE �F COL�RADO
; ��y�
�.. F � ...
Co1Q�-a'c
s i; ` .
� '���
��� � ��� , .,.
�
{ �' �� i �' v�t �•
,��� �����.� ���t, - �. .
,� � -
+z,, � �.
� � �` �
� t�:;� ;
��
� ..
�x ��`ii,. J �
`, ��e' `' ' :'!'�1.�' : A
F
;: w ,�
_ � y .,
t���y� 1�
5-a�u
;._ ' ,,. ;. '':
has met th�:xec
'�ommissioi�l
Tssued: 10/1
��`�FI�A�IQ��
�3� �liih �.�. fr.�- !k
{' � ... `� � tr
� Depa.r�� of Public'��e�
�....
���', �������t - ..
..: ...,n,. . y,.. . �. .:,.�:'=w . . . _ ..., ....
� .�
�u� �er��fi�s tl�at
r t�':
��IIa x�����l��Y'
—� �---'
i2r� .i ii �.t� .Jinc �.
.i,r.�r.z a k'�da�:?i-s lk �:;-, i
�tifica��"on t�a; 15`7�,73
F�"
0
olor� in t%e fo1lo�Yir
� _'
�{" .�'�=BUI��In�'rc����i=Sr
.�-_:L 4" .0
. _ ; y, �/+ ::`'
�. . �x�:�fvii�. �S'
�Zd�'� , � �, � �
r ;�1:..`�_
ty
1
u�
�
Ir1�F r�
�' r
KY w'�•
�
' � .v
.'?,4"` �� _�k r. �
��
_'.5-r, ��'"h ��� � � � 1 .
�..•. ,s`. � 1
f '�1 .
� !�a �eii
�� v.1 r �
4
.. '� �,C�l�'a" 4
, ,.
� y .� '
� _
� �,r �
�� :
,�
�•��, ST�`'6 Jr x8
+�i ;1� t $ fi3!��r�j;'.
� C�tI�.P!
�ir +���lity �oi
r.
�y c��'rtified by
. .:k�� «
r,�;F
� , � r.�::..;
y� .._.
...,;;:, .�rb,th-- �;r _ -
•;,} �, r
- rtL ... .
. _� �u�l 4 ..-
es on: 10/14/2U12 � "'
. . - f� � �...
.
-
�„"v ..._..� ' fy thorized APCD RepresentatNe
/
bis cert�cale is valid only with the possesslon of a current Dtvislon-approred tralning coarse
Yficatton in the dlsclpline specl�Jed a6ove.
y�:LL��;a,:�" r�`„°,
/..�.
;�;
�
�y.
t
..` 'i
�►�x
sp
f
%
f�
�;
��';
g�6
{�
/
:-��
����;
�s�+
�ro f
Y f
E `-�m
� :�
�°v
^i ,
a
��y
,�
��k,,'1
b
r� �_ '
� m
�
•r�\
�±
' b� fi
�~ i I
�o
p� .
�8 y
'4 +
,"„'�, `
T$ro� 'i
�` `
�
��: `ti
�m;fr ;
.
ae�.
E".k
�O
��
✓
(:
a
e'�
• �
=' �
w�
i�`1 .
�
�4�.
01-11-2013
A . i 7 ....,
Inspection Request Re�orting
va�i �n _ ��+., n
c
Requested Inspect Date: Monday January 14, 2013
Site Address: 160 GO�tE CREEK DR VAIL
LODGE AT VAIL COMMERICAL SPACE
Page 9
A/P/D Information
Activity: B11-0510 Type: COMBO Sub Type: ACOM Status: ISSUED
Const Type: Occu ancy: Use: M Insp Area:
Contractor: SRE BUILDING ASSOCIA�ES Phone: 970-945-6359
Owner: MOUNTAIN WOLF PROPERTIES LLC
Description: TENANT IMPROVEMENT REMODEL RETAIL INTO BAKERY (MOUNTAIN CUPCAKE)
Reauested Ins�ection(s)
Rem: 90 BLDG-Final
Requestor: SRE BUIL G ASSOCIATES
Comments: follo u
Assigned To: S
Action: Time Exp:
Comment: ir i n o
Ne sign over door " To ramain open while occupied"
Comment: Ne ire to sign off
Ins�ection Historv
Item: 120 ELEC-Rough
05/16/12 Inspector:
Comment:
Item: 200 MECH-Rou h
05/09/1 � Inspector:
Comment:
ftem: 230 PLMB-Rough/Water
05/14/1 Z Inspector:
Comment:
ftem: 240 PLMB-Gas Piping
05/30/12 Inspector:
Comment: NA
Item: 260 PLMB-Misc.
05/30/12 Inspector:
Comment:, NA
Item: 310 MECH-Heatmg
05/30/12 fnspector:
Comment: NA
Item: 320 MECH-Exhaust Hoods
05/30/12 Inspector:
Comment:
ttem: 330 MECH-Suppfy Air
05/30/i2 Inspector:
Comment: NA
Item: 340 MECH-Misc.
05/30/12 Inspector:
Comment: NA
Item: 30 BLDG-Framing
05/17/12 Inspector:
Comment:
ttem: 50 BLDG-Insulation
05/18/12 Inspector:
Comment:
ftem: 60 BLDG-Sheetrock Nail
05/18/12 Inspector:
Comment:
ftem: 190 ELEC-Final
05/30/12 Inspector:
*" Approved "
sgremmer
•• Approved "
sgremmer
" Approved "
sgremmer
" Approved "
sgremmer
•« qPProved «•
sgremmer
" Approved "
sgremmer
*' Approved *'
sgremmer
" Approved "
sgremmer
" Approved "'
sgremmer
" Approved '"
sgremmer
JRIVi roved "
JRM PProved "
" Approved "
sgremmer
Requested Time: 02:00 PM
Phone: 970-390-5776
Entered By: JMONDRAGON K
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
REPT131 Run Id: 14637