Loading...
HomeMy WebLinkAboutHadley Residence Material Submittal 2 of 2 COPPER PIPE AND FITTINGS Date Product Certification Mueller Copper Tube products are all manufactured in the USA. All tubing produced in Fulton, MS, and Wynne, AR, is seamless and of UNS C12200 grade of copper and is manufactured to meet the chemical and mechanical properties of the applicable ASTM specifications set forth below. When specified at order placement, Mueller Copper Tube can supply Certified Tube to meet all requirements of the current applicable ASTM specification, at an additional cost. Streamline Copper Water Tube (Types K,L,M) ASTM B88 and ANSI/NSF 61 Streamline Copper Refrigeration Service Coils ASTM B280 Streamline Nitrogenized ACR Hard Drawn Copper Tube ASTM B280 Streamline Copper Drainage Tube (DWV) ASTM B306 * Please contact Technical Services for certification in Oxygen and Medical service tube. (1.662.862.1700) Oxygen & Medical Service Tube To ASTM B819 (Types K & L) Hard Drawn Straight Lengths Only in Accordance To CGA Cleanness Specification; CGA G4.1 (Compressed Gas Association); & NFPA 99 (Health Care Facilities). NSF 61 Restriction Statement: “Copper Tube (Alloy C12200) is certified by NSF to ANSI/NSF Standard 61 for public water supplies meeting or in the process of meeting the U.S. EPA Lead and Copper Rule (56FR 26460, June 7, 1991). Water supplies with pH less than 6.5 may require corrosion control to limit copper solubility in drinking water.” P. O. BOX 849 uFULTON, MS 38843 u (662) 8621700 uFAX (662) 8623002 P. O. BOX 309 uWYNNE, AR 72396 u(870) 2383201 uFAX (870) 2388724 2.09 2.14 2.63 1.72 1.77 2.33 – – 2.28 1.99 3.59 3.83 4.71 2.65 2.77 3.60 2.09 – 4.06 3.14 4.28 4.48 5.47 3.08 3.69 4.41 2.18 – 4.62 3.83 5.35 5.76 7.05 4.70 5.06 6.23 3.53 – 5.95 5.42 7.97 8.25 9.84 4.91 5.88 6.76 3.54 – 8.47 6.00 10.44 10.79 12.93 7.39 8.47 9.63 5.75 – 11.20 8.70 12.93 13.73 15.90 10.56 12.10 13.52 8.47 9.10 13.68 11.65 16.92 17.97 21.30 13.61 15.51 17.43 11.70 11.47 18.37 14.92 26.03 28.94 33.06 21.25 25.04 27.44 18.47 15.22 28.43 23.50 38.33 – 49.18 31.57 – 39.39 27.01 – 42.51 35.03 53.28 – 68.74 42.36 – 52.91 35.73 25.16 57.97 47.12 68.92 – – 55.22 – – 48.35 – 75.32 61.59 88.09 – – 70.05 – – 62.80 43.02 96.30 78.35 194.59 – – 146.55 – – 146.55 127.74 225.67 202.13 279.17 – – 196.11 – – 196.11 177.08 323.92 246.62 522.82 – – 371.59 – – 371.59 – 606.35 455.80 ®Registered Trademark of Mueller Industries 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.MuellerIndustries.com UW CT0808 Effective August 18, 2008 Page 1 The issance of this price list is not an offer to sell the goods listed herein at the prices stated. ORIGINATORS OF THE SOLDER-TYPE FITTING. COPPER TUBE UW CT0808 Effective August 18, 2008 (Supercedes UW CT0608) The issuance of this price list is not an offer to sell the goods listed herein at the prices stated. O.D. 3/8" 1/2" 5/8" 3/4" 7/8" 1-1/8" 1-3/8" 1-5/8" 2-1/8" 2-5/8" 3-1/8" 3-5/8" 4-1/8" 5-1/8" 6-1/8" 8-1/8" NOM 1/4" 3/8" 1/2" 5/8" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4" 5" 6" 8" Type K Type L Type M DWV Nitrogenized®* ACR /MED *(Nitrogenized thru 3-1/8" Only) WATER TUBE /PRICE PER FOOT Hard Soft Soft Hard Soft Soft Hard Hard Type K Type L Lengths Coils Lengths Lengths Coils Lengths Lengths Lengths Diameter Type K Type L Coated ACR Tube NOM O.D. Lengths Coils Lengths Coils Type K Type L 1/4" 3/8" – 2.68 – 2.31 – – 3/8" 1/2" – 4.37 – 3.31 – – 1/2" 5/8" 4.82 5.02 3.62 4.23 5.16 4.37 5/8" 3/4" 5.89 6.30 5.24 5.60 6.49 5.96 3/4" 7/8" 8.51 8.79 5.45 6.42 9.01 6.54 1" 1-1/8" 10.98 11.33 7.93 9.01 11.74 9.24 1-1/4" 1-3/8" 13.47 14.27 11.10 12.64 14.22 12.19 1-1/1/2" 1-5/8" 17.46 18.51 14.15 16.05 18.91 15.46 2" 2-1/8" 26.57 – 21.79 – 28.97 24.04 O.D. 3/8" 1/2" 5/8" 3/4" 7/8" 1-1/8" 50' Soft Coil 109.18 134.75 173.14 202.79 289.27 404.55 100' Soft Coil 226.72 277.60 357.22 411.85 585.46 829.16 250' Soft Coil 566.80 694.00 893.05 – – – O.D. 1/8" 3/16" 1/4" 5/16" 3/8" 1/2" 5/8" 3/4" 7/8" 1-1/8" 1-3/8" 1-5/8" 50' Soft Coil 39.86 46.63 55.31 71.96 82.18 107.75 146.14 175.79 262.27 377.55 578.70 734.67 100' Soft Coil 83.17 97.08 114.64 149.49 172.72 223.60 303.22 357.85 531.46 775.16 1141.63 1469.34 1/4" 0.025 2.05 HARD REFRIGERATION SERVICE TUBE /PRICE PER COIL PLASTIC COATED REFRIGERATION SERVICE TUBE /PRICE PER COIL O.D. Wall Price/FT TEMPERATURE CONTROL TUBE /PRICE PER FOOT NOT RECOMMENDED FOR BENDING OR FORMING PURPOSES. ORDER QUANTITY IS IN 2000 FEET PER BOX INCREMENTS. O.D. Wall Price/FT 1/4" 0.025 2.67 O.D. Wall Price/FT 1/4" 0.032 2.43 O.D. Wall Price/FT 1/4" 0.032 3.15 SOFT HARD SOFT PlumbShield™ available in blue for cold, red for hot and purple for reclaimed reclaimed water applications GasShield™ available in yellow for natural and LP gas applications OilShield™ available in orange for fuel oil applications Coated ACR available in white for refrigeration applications * HARD LENGTHS AVAILABLE IN 20' AND COILS AVAILABLE IN 60' AND 100' WHERE APPLICABLE. PLASTIC COATED WATER TUBE /PRICE PER FOOT Diameter 1/4" 3/8" 3/8" 1/2" 1/2" 5/8" 5/8" 3/4" 3/4" 7/8" 1" 1-1/8" 1-1/4" 1-3/8" 1-1/2" 1-5/8" 2" 2-1/8" 2-1/2" 2-5/8" 3" 3-1/8" 3-1/2" 3-5/8" 4" 4-1/8" 5" 5-1/8" 6" 6-1/8" 8" 8-1/8 1/8" 0.030 0.0347 1.74 14-3/4" 10 17.4 3/16" 0.030 0.0575 2.88 14-3/4" 10 28.80 1/4" 0.030 0.0804 4.02 14-3/4" 10 40.20 5/16" 0.032 0.109 5.45 14-3/4" 10 54.50 3/8" 0.032 0.134 6.70 16-1/2" 10 67.00 1/2" 0.032 0.182 9.10 20" 5 45.50 5/8" 0.035 0.251 12.55 22" 5 62.75 3/4" 0.035 0.305 15.25 25" 3 45.75 7/8" 0.045 0.455 22.75 27-1/2" 3 22.75 1-1/8" 0.050 0.655 32.75 34-1/2" — 32.75 1-3/8" 0.055 0.884 44.20 39-1/2" — 44.20 1-5/8" 0.060 1.14 57.00 42" — 57.00 REFERENCE INFORMATION COPPER TUBE STANDARD* LENGTHS Type K Type L /ACR Type M DWV O.D. 0.035 0.049 0.049 0.049 0.065 0.065 0.065 0.072 0.083 0.095 0.109 0.120 0.134 0.160 0.192 0.271 0.145 0.269 0.344 0.418 0.641 0.839 1.04 1.36 2.06 2.93 4.00 5.12 6.51 9.67 13.90 25.90 0.030 0.035 0.040 0.042 0.045 0.050 0.055 0.060 0.070 0.080 0.090 0.100 0.110 0.125 0.140 0.200 0.126 0.198 0.285 0.362 0.455 0.655 0.884 1.14 1.75 2.48 3.33 4.29 5.38 7.61 10.20 19.30 0.025 0.025 0.028 0.030 0.032 0.035 0.042 0.049 0.058 0.065 0.072 0.083 0.095 0.109 0.122 0.170 0.106 0.145 0.204 0.263 0.328 0.465 0.682 0.940 1.46 2.03 2.68 3.58 4.66 6.66 8.92 16.46 —————— 0.040 0.042 0.042 — 0.045 — 0.058 0.072 0.083 — —————— 0.650 0.809 1.07 — 1.69 — 2.87 4.43 6.10 — NOM O.D. WALL WGT/FT WALL WGT/FT WALL WGT/FT WALL WGT/FT REFRIGERATION SERVICE TUBE PACKED 2000' PER BOX O.D. WALL WGT/FT 1/4" 0.025 0.0685 TEMPERATURE CONTROL TUBE PLASTIC COATED COPPER TUBE O.D. WALL WGT/FT 1/4" 0.032 0.0849 * FOR SPECIAL LENGTHS OR TEMPERS CONSULT FOR PRICE AND AVAILABILITY. Polyethylene coating made from low density LDPE resin and is extruded at 0.025" minimum wall. ®Registered Trademark of Mueller Industries 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.MuellerIndustries.com UW CT0808 Effective August 18, 2008 Page 2 * STANDARD 50' COIL – 100' COILS ALSO AVAILABLE AS STANDARD STOCK ITEM. WALL WEIGHT WEIGHT COIL COILS WEIGHT THICKNESS PER FOOT PER COIL* DIAMETER PER MASTER PER MASTER HARD 20' Lengths HARD 20' Lengths HARD 20' Lengths HARD 20' Lengths COILS 60' thru 1-1/2 COILS 60' thru 1-1/2 COILS Consult 100' thru 1-1/4 100' thru 1-1/4 40' and 60' -2" only 40' -2" only MUELLER FITTINGS COMPANY INC. 3400 MUELLER BRASS ROAD, COVINGTON, TN 38019 PHONE: (901) 476-5858 FAX: (901) 475-1334 DECLARATION OF CONFORMANCE Mueller Fittings Co. Inc. manufactures or supplies product which are manufactured to meet the following specifications. ASME B16.22 Wrought Copper and Copper Alloy Solder Joint Pressure Fittings MSS SP-104 Wrought Copper Solder Joint Pressure Fittings ASME B16.29 Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings -DWV ASME/ANSI B16.18 Cast Copper Alloy Solder Joint Pressure Fittings ASME/ANSI B16.15 Cast Bronze Threaded Fittings ASME/ANSI B16.23 Cast Copper Alloy Solder Joint Drainage Fittings – DWV MSS SP-106 Class 150-Cast Copper Flanges shall meet the requirements of MSS SP-106 and/or the workmanship and dimensional of Federal Spec. WW-F-406 ASME B16.24. MSS SP – 106 Class 125 Bronze Pipe Flanges and Flanged Fittings MSS SP – 109 Welded Fabricated Copper Solder Joint Pressure Fittings MSS SP -123 Threaded and Solder Joint Copper Unions The materials used to manufacture these fittings are also in compliance with the following specifications. Products Made From Sheet ASTM B152 Alloy C11000 Standard Specification for Copper Sheet, Strip, Plated Rolled Bar Cast Products ASTM B584 Alloy C84400 Standard Specification for Copper Alloy Sand Castings for General Applications: Federal Specification WW-U-516 for Type III, Class A and B Copper Alloy Unions. Copper Fittings ASTM B75 Alloy C12200 Standard Specification for Seamless Round, Copper Tube for or Alloy C10200 General Engineering applications. COPPER FITTINGS – WROT SOLDER JOINT PRESSURE & DWV UW CFW0908 Effective September 15, 2008 (Supersedes UW CFW0308) The issuance of this price list is not an offer to sell the goods listed herein at the prices stated. ADAPTER FEMALE WC-402 C x F Part Size Box Ctn Wt List W 01207 1/8 100 1500 0.03 10.11 W 01215 1/4 50 750 0.04 8.69 W 01225 3/8 50 750 0.06 8.89 WB01231 1/2 50 500 0.1 4.26 WB01246 3/4 25 250 0.14 5.84 WB01263 1 10 100 0.24 13.49 W 01271 1-1/4 10 100 0.43 19.76 W 01279 1-1/2 10 100 0.58 30.90 W 01287 2 -50 0.74 41.97 W 01296 2-1/2 -25 1.19 152.86 W 01297 3 -15 1.83 225.46 REDUCING W 01204 1/8 x 1/2 100 300 0.11 7.73 W 01205 x 3/8 100 700 0.06 8.30 W 01206 x 1/4 100 900 0.04 10.53 W 01214 1/4 x 3/8 50 750 0.06 8.30 W 01216 x 1/8 100 1500 0.03 9.65 W 01223 3/8 x 3/4 50 300 0.13 11.13 W 01224 x 1/2 50 500 0.1 8.69 W 01226 x 1/4 50 750 0.05 7.68 WB01230 1/2 x 3/4 25 250 0.15 9.22 W 01232 x 3/8 50 500 0.07 6.62 W 01233 x 1/4 50 500 0.05 6.62 W 01238 5/8 x 3/4 50 500 0.14 10.07 W 01239 x 1/2 50 500 0.09 12.82 W 01245 3/4 x 1 25 250 0.24 19.76 W 01247 x 1/2 25 250 0.11 9.22 W 01261 1 x 1-1/4 10 100 0.28 35.48 W 01264 x 3/4 25 250 0.22 19.76 W 01265 x 1/2 20 200 0.29 24.70 W 01270 1-1/4 x 1-1/2 10 100 0.52 42.20 W 01272 x 1 10 100 0.33 41.76 W 01278 1-1/2 x 2 -60 0.72 78.44 W 01280 x 1-1/4 5 50 0.42 45.92 W 01288 2 x 1-1/2 5 50 0.74 68.30 ADAPTER FITTING WC-405 FTG x F Part Size Box Ctn Wt List W 01525 3/8 50 750 0.05 11.66 W 01531 1/2 50 450 0.11 8.48 W 01546 3/4 25 250 0.19 10.95 W 01563 1 25 250 0.25 19.57 W 01571 1-1/4 10 100 0.43 31.63 W 01579 1-1/2 10 100 0.55 41.52 W 01587 2 -50 0.68 55.18 W 01596 2-1/2 -25 1.21 297.55 REDUCING W 01514 1/4 x 3/8 50 750 0.06 12.98 W 01524 3/8 x 1/2 50 350 0.11 12.50 W 01526 x 1/4 50 750 0.06 29.45 W 01532 1/2 x 3/8 50 750 0.07 11.44 W 01547 3/4 x 1/2 50 500 0.11 22.13 W 01564 1 x 3/4 25 250 0.17 43.22 ADAPTER MALE WC-401 C x M Part Size Box Ctn Wt List W 01107 1/8 50 2400 0.02 16.96 W 01115 1/4 50 1200 0.03 13.33 W 01125 3/8 50 500 0.06 6.62 WB01131 1/2 50 500 0.08 2.68 WB01146 3/4 25 250 0.14 4.50 WB01163 1 10 100 0.24 11.62 W 01171 1-1/4 10 100 0.411 17.21 1 2 1 2 ADAPTER (CONT.) W 01179 1-1/2 10 100 0.541 19.76 W 01187 2 5 50 0.87 33.43 W 01196 2-1/2 -20 1.22 128.12 W 01199 3 -20 1.72 164.92 W 01150 4 -16 3.71 229.50 REDUCING W 01105 1/8 x 3/8 50 750 0.06 15.62 W 01106 x 1/4 50 1200 0.03 12.08 W 01113 1/4 x 1/2 50 500 0.09 7.81 W 01114 x 3/8 50 750 0.06 15.96 W 01116 x 1/8 50 2000 0.02 11.48 W 01123 3/8 x 3/4 25 250 0.17 9.63 W 01124 x 1/2 50 500 0.09 9.01 W 01126 x 1/4 50 750 0.06 15.62 W 01129 1/2 x 1 15 150 0.28 17.55 WB01130 x 3/4 25 250 0.16 7.81 W 01132 x 3/8 50 500 0.06 6.85 W 01133 x 1/4 25 600 0.06 8.24 W 01138 5/8 x 3/4 25 250 0.14 10.07 W 01139 x 1/2 25 250 0.12 15.13 W 01145 x 1 10 100 0.29 17.21 W 01147 x 1/2 25 250 0.13 7.81 W 01161 1 x 1-1/2 10 100 0.5 47.60 W 01162 x 1-1/4 10 100 0.4 25.33 W 01164 x 3/4 10 100 0.18 17.21 W 01165 x 1/2 10 100 0.18 21.45 W 01170 1-1/4 x 1-1/2 10 100 0.51 40.20 W 01172 x 1 10 100 0.29 25.68 W 01173 x 3/4 10 100 0.29 29.61 W 01178 1-1/2 x 2 -50 0.79 74.98 W 01180 x 1-1/4 10 100 0.44 40.00 W 01181 x 1 10 100 0.38 47.52 W 01188 2 x 1-1/2 -50 0.6 77.32 W 01189 x 1-1/4 -50 0.64 77.32 W 01197 2-1/2 x 2 -20 0.98 216.19 W 01198 x 1-1/2 -22 0.97 220.59 ADAPTER FITTING WC-404 FTG x M Part Size Box Ctn Wt List W 01425 3/8 50 750 0.05 11.43 W 01431 1/2 50 500 0.09 11.84 W 01446 3/4 50 500 0.15 15.23 W 01463 1 25 250 0.24 19.35 W 01471 1-1/4 10 100 0.41 59.84 W 01479 1-1/2 10 100 0.52 72.51 W 01487 2 -50 0.86 117.19 W 01496 2-1/2 -20 1.54 255.83 REDUCING W 01432 1/2 x 3/8 50 750 0.06 27.36 W 01447 3/4 x 1/2 50 500 0.13 28.54 W 01464 1 x 3/4 25 250 0.19 31.67 AIR CHAMBER WA-515 FTG Part Size Box Ctn Wt List W 06000 1/2 x 6 -100 0.22 11.18 W 06001 x 12 -50 0.42 16.78 W 06002 3/4 x 12 -72 0.41 20.73 BUSHING FLUSH WC-106 FTG Part Size Box Ctn Wt List W 01706 1/4 x 1/8 100 4000 0.01 2.23 W 01712 3/8 x 1/4 100 3400 0.01 2.20 W 01714 x 1/8 100 2400 0.02 2.53 W 01715 1/2 x 3/8 100 1500 0.02 2.66 1 2 1 2 BUSHING (CONT.) W 01717 x 1/4 100 1500 0.04 3.03 W 01720 5/8 x 1/2 50 750 0.03 3.25 W 01721 x 3/8 50 750 0.06 3.95 W 01722 x 1/4 50 750 0.08 3.68 W 01725 3/4 x 5/8 50 500 0.04 5.17 W 01726 x 1/2 50 500 0.08 4.96 W 01727 x 3/8 50 500 0.11 5.62 W 01737 1 x 3/4 50 500 0.13 7.59 W 01738 x 5/8 50 500 0.18 8.76 W 01739 x 1/2 25 250 0.22 8.54 W 01743 1-1/4 x 1 10 200 0.16 9.41 W 01745 x 3/4 10 200 0.3 11.73 W 01750 1-1/2 x 1-1/4 10 100 0.22 12.38 W 01751 x 1 10 100 0.41 13.30 W 01758 2 x 1-1/2 10 100 0.68 35.48 W 01759 x 1-1/4 5 50 0.95 40.13 W 01767 2-1/2 x 2 -50 0.92 230.25 BUSHING FLUSH WC-417 FTG x F (BRASS) Part Size Box Ctn Wt List A 07813 1/2 x 1/4 50 1200 0.02 7.84 A 07812 x 1/8 100 1600 0.04 7.46 A 07814 3/4 x 3/8 50 450 0.08 16.50 A 07815 1 x 1/2 50 300 0.17 25.15 A 07816 1-1/4 x 3/4 10 160 0.25 42.98 A 07817 1-1/2 x 1 10 90 0.34 45.06 A 07819 2 x 1-1/2 10 90 0.48 49.34 ***Call for net prices CAP WC-415 C Part Size Box Ctn Wt List W 07002 1/8 50 2000 0.01 1.89 W 07004 1/4 50 2000 0.01 1.18 W 07006 3/8 50 1000 0.01 1.87 WB07007 1/2 50 1000 0.02 0.93 W 07008 5/8 50 2000 0.03 2.23 WB07009 3/4 25 1000 0.04 1.74 WB07011 1 10 500 0.08 4.11 W 07012 1-1/4 25 250 0.11 5.51 W 07013 1-1/2 25 250 0.18 8.06 W 07014 2 -100 0.3 14.86 W 07015 2-1/2 -50 0.48 47.45 W 07016 3 -50 0.73 63.27 W 07017 3-1/2 -25 1.15 193.39 W 07018 4 -20 1.5 116.03 COUPLING NO STOP WC-400NS C x C Part Size Box Ctn Wt List W 01900 1/8 100 4000 0.01 1.89 W 01901 1/4 50 2000 0.01 0.76 W 01902 3/8 50 1700 0.02 2.66 W 01903 1/2 100 1000 0.03 1.28 W 01904 5/8 25 375 0.04 3.83 W 01905 3/4 50 500 0.06 2.66 W 01906 1 25 250 0.11 5.62 W 01907 1-1/4 25 250 0.15 8.47 W 01908 1-1/2 10 100 0.21 11.46 W 01909 2 -75 0.38 19.35 W 01910 2-1/2 -50 0.68 25.34 W 01911 3 -25 1.06 48.22 W 01913 4 -15 2.05 89.82 1 2 All sizes are nominal. UW CFW0908 Effective September 15, 2008 Page 1 SOLDER JOINT PRESSURE FITTINGS 1 2 All sizes are nominal. Page 2 UW CFW0908 Effective September 15, 2008 Copper Fittings -Wrot hCOUPLING ROLLED STOP WC-400 C x C Part Size Box Ctn Wt List W 01003 1/8 100 4000 0.01 1.12 W 01009 1/4 50 2000 0.01 0.94 W 01017 3/8 50 1700 0.02 1.20 WB01022 1/2 50 1000 0.03 0.98 W 01028 5/8 50 500 0.04 2.74 WB01034 3/4 25 500 0.06 1.95 WB01047 1 10 250 0.11 3.93 W 01055 1-1/4 25 250 0.15 6.90 W 01063 1-1/2 10 100 0.21 9.12 W 01072 2 -75 0.38 14.82 W 01082 2-1/2 -50 0.68 34.30 W 01092 3 -25 1.03 48.33 W 10100 3-1/2 -20 1.4 90.68 W 10107 4 -15 2.07 106.89 COUPLING STAKED STOP WC-400S C x C Part Size Box Ctn Wt List W 10141 1/8 100 3400 0.01 1.10 W 10143 1/4 50 2000 0.01 0.91 W 10144 3/8 50 1700 0.02 1.24 W 10145 1/2 100 1000 0.03 0.92 W 10157 5/8 25 500 0.04 2.90 W 10146 3/4 50 500 0.06 1.89 W 10147 1 25 250 0.11 3.77 W 10148 1-1/4 25 250 0.15 6.90 W 10149 1-1/2 10 100 0.21 9.12 W 10150 2 -75 0.38 15.23 W 10151 2-1/2 -50 0.68 32.33 W 10152 3 -25 1.02 47.30 W 10153 3-1/2 -20 1.48 90.68 W 10154 4 -15 2.03 96.71 W 10155 5 -8 3.24 238.08 W 10156 6 -3 5.58 393.48 W 10130 8 -1 1,275.27 COUPLING REDUCING WC-400R C x C Part Size Box Ctn Wt List W 01011 1/4 x 1/8 50 2000 0.01 6.04 W 01019 3/8 x 1/4 50 1700 0.02 2.08 W 01021 x 1/8 50 1200 0.02 2.79 W 01023 1/2 x 3/8 100 1000 0.03 2.03 W 01025 x 1/4 100 1000 0.03 2.46 W 01027 x 1/8 100 1000 0.03 2.71 W 01029 5/8 x 1/2 100 600 0.05 4.96 W 01030 x 3/8 100 600 0.03 6.13 W 01031 x 1/4 100 600 0.04 5.41 W 01035 3/4 x 5/8 100 1000 0.06 3.51 WB01036 x 1/2 25 500 0.08 3.45 W 01037 x 3/8 50 500 0.06 4.36 W 01038 x 1/4 50 500 0.06 4.29 W 01049 1 x 3/4 25 250 0.13 6.38 W 01050 x 5/8 25 250 0.1 6.85 W 01051 x 1/2 25 250 0.11 7.57 W 01052 x 3/8 25 250 0.1 7.81 W 01056 1-1/4 x 1 10 100 0.18 8.98 W 01058 x 3/4 10 100 0.17 8.98 W 01060 x 1/2 10 100 0.15 9.33 W 01064 1-1/2 x 1-1/4 10 100 0.24 14.88 W 01065 x 1 10 100 0.24 14.88 W 01067 x 3/4 10 100 0.22 14.88 W 01069 x 1/2 10 100 0.23 15.80 W 01073 2 x 1-1/2 -100 0.39 23.01 W 01074 x 1-1/4 -100 0.41 23.01 W 01075 x 1 -100 0.38 24.24 W 01077 x 3/4 -100 0.39 24.73 W 01079 x 1/2 -75 0.4 25.77 W 01083 2-1/2 x 2 -50 0.68 50.88 W 01084 x 1-1/2 -50 0.72 51.96 W 01085 x 1-1/4 -50 0.77 58.73 W 01086 x 1 -50 0.78 59.09 W 01093 3 x 2-1/2 -25 1 65.10 W 01094 x 2 -25 1.02 63.78 W 01095 x 1-1/2 -25 1.12 71.25 W 10101 3-1/2 x 3 -25 1.49 110.19 W 10108 4 x 3-1/2 -20 1.94 147.76 W 10109 x 3 -20 1.91 129.89 W 10110 x 2-1/2 -15 1.99 147.76 W 10111 x 2 -20 2 142.07 1 2 COUPLING (CONT.) W 10116 5 x 4 -1 3.31 541.84 W 10123 6 x 4 -1 4.82 839.43 W 10124 x 3 -1 4.85 839.43 COUPLING CROSS OVER WC-412 C x C Part Size Box Ctn Wt List A 02535 1/2 5 100 0.12 21.57 A 02583 3/4 5 50 0.26 81.64 45° ELBOW WE-504 C x C Part Size Box Ctn Wt List W 03005 1/8 50 2000 0.01 9.63 W 03012 1/4 50 2800 0.01 7.21 W 03021 3/8 50 850 0.02 6.16 WB03026 1/2 50 500 0.04 2.35 W 03030 5/8 50 500 0.06 11.17 WB03034 3/4 25 250 0.1 4.11 WB03044 1 10 200 0.18 10.34 W 03050 1-1/4 10 100 0.21 13.98 W 03055 1-1/2 10 100 0.3 16.84 W 03059 2 10 50 0.55 28.11 W 03063 2-1/2 5 25 1.41 59.90 W 03067 3 2 20 1.87 1.87 86.47 W 03070 3-1/2 2 10 3.35 152.42 W 03073 4 -5 4.68 179.18 W 03074 5 -1 6.56 694.02 W 03075 6 -1 10.64 1,093.99 45° ELBOW STREET WE-505 FTG x C Part Size Box Ctn Wt List W 03312 1/4 100 3400 0.01 10.69 W 03321 3/8 100 1500 0.02 8.40 WB03326 1/2 50 500 0.04 2.81 W 03330 5/8 50 500 0.06 16.89 WB03334 3/4 25 250 0.1 4.14 W 03344 1 25 250 0.17 13.65 W 03350 1-1/4 10 100 0.31 17.21 W 03355 1-1/2 10 100 0.43 21.03 W 03359 2 5 50 0.86 33.43 W 03363 2-1/2 2 20 1.43 79.51 W 03368 3 2 10 1.92 104.82 W 03373 4 -5 4.62 527.54 45° ELBOW WE-507 FTG x FTG Part Size Box Ctn Wt List W 03621 3/8 50 1700 0.02 15.92 W 03626 1/2 50 750 0.04 15.92 W 03634 3/4 25 250 0.1 17.86 W 03644 1 10 100 0.18 15.13 90° ELBOW SHORT RADIUS WE-500 C x C Part Size Box Ctn Wt List W 02003 1/8 50 2000 0.01 3.83 W 02009 1/4 50 1700 0.02 3.83 W 01617 3/8 50 750 0.03 3.83 WB01622 1/2 50 500 0.04 1.28 W 02028 5/8 50 500 0.1 7.21 WB01634 3/4 25 250 0.09 2.87 WB01647 1 10 100 0.18 7.05 W 02084 1-1/4 10 100 0.31 10.66 W 02085 1-1/2 10 100 0.43 16.62 W 02086 2 10 50 0.86 29.48 W 02087 2-1/2 5 25 1.4 60.64 W 02088 3 5 25 1.99 78.83 W 02089 3-1/2 2 10 2.74 275.55 W 02090 4 2 10 3.8 207.39 W 02096 5 -1 8.59 821.72 W 02097 6 -1 11.73 1,095.61 W 02099 8 -1 27 4,055.51 1 2 90° ELBOW (CONT.) REDUCING W 02011 1/4 x 1/8 50 750 0.02 10.55 W 02019 3/8 x 1/4 50 750 0.03 6.64 W 02023 1/2 x 3/8 50 500 0.04 10.69 W 02025 x 1/4 50 500 0.05 10.69 W 02029 5/8 x 1/2 50 500 0.08 9.69 W 02030 x 3/8 50 500 0.07 8.32 W 02035 3/4 x 5/8 50 500 0.11 7.26 W 02036 x 1/2 50 500 0.1 7.44 W 02037 x 3/8 50 500 0.1 8.18 W 02049 1 x 3/4 25 250 0.17 13.65 W 02050 x 5/8 25 250 0.16 15.56 W 02051 x 1/2 25 250 0.18 15.23 W 02052 x 3/8 25 150 0.2 15.92 W 02056 1-1/4 x 1 20 200 0.31 34.75 W 02077 1-1/2 x 1-1/4 5 100 0.33 45.67 W 02078 2 x 1-1/2 5 50 0.6 61.57 90° ELBOW LONG RADIUS WE-500L C x C Part Size Box Ctn Wt List W 02715 1/8 50 2000 0.01 7.21 W 02716 1/4 50 1700 0.02 5.42 W 02717 3/8 50 500 0.04 6.82 W 02722 1/2 50 500 0.06 5.83 W 02728 5/8 50 500 0.11 5.91 W 02734 3/4 25 250 0.15 7.52 W 02747 1 10 100 0.26 12.08 W 02055 1-1/4 10 100 0.44 19.82 W 02063 1-1/2 5 50 0.61 26.62 W 02072 2 5 25 1.19 70.04 W 02082 2-1/2 5 25 2.06 110.89 W 02092 3 2 10 3.05 156.18 W 02093 3-1/2 1 5 4.95 562.36 W 02095 4 -1 7.75 396.61 REDUCING W 02711 1/4 x 1/8 50 3000 0.01 18.88 W 02723 1/2 x 3/8 50 1000 0.04 16.07 W 02725 x 1/4 50 1000 0.03 15.24 W 02735 3/4 x 5/8 25 250 0.12 18.12 W 02736 x 1/2 50 500 0.09 17.77 W 02749 1 x 3/4 10 100 0.17 27.02 W 02756 1-1/4 x 1 10 100 0.31 31.07 W 02058 x 3/4 10 100 0.35 30.04 W 02060 x 1/2 10 100 0.4 30.04 W 02064 1-1/2 x 1-1/4 5 50 0.44 48.24 W 02065 x 1 5 50 0.52 48.24 W 02067 x 3/4 5 50 0.51 48.24 W 02073 2 x 1-1/2 2 20 0.89 76.66 W 02074 x 1-1/4 2 20 0.95 76.66 W 02075 x 1 2 20 1.05 76.66 90° ELBOW STREET SHORT RADIUS WE-503 FTG x C Part Size Box Ctn Wt List W 02305 1/8 50 2000 0.01 7.16 W 02312 1/4 50 1700 0.02 6.74 W 02321 3/8 50 750 0.03 4.88 WB01652 1/2 50 500 0.04 1.96 W 02330 5/8 25 250 0.1 7.65 WB01654 3/4 25 250 0.1 4.14 W 02334 3/4 25 250 0.11 8.81 WB02344 1 10 100 0.21 10.72 W 02384 1-1/4 25 125 0.31 16.25 W 02385 1-1/2 10 100 0.43 21.30 W 02386 2 10 50 0.86 46.40 W 02387 2-1/2 5 25 1.36 79.19 W 02388 3 2 20 1.99 114.88 W 02389 3-1/2 1 10 2.83 455.70 W 02390 4 2 10 3.89 256.58 1 2 All sizes are nominal. UW CFW0908 Effective September 15, 2008 Page 3 90° ELBOW STREET LONG RADIUS WE-503L FTG x C Part Size Box Ctn Wt List W 02809 1/4 50 1700 0.03 6.39 W 02817 3/8 50 500 0.04 12.57 W 02822 1/2 50 500 0.07 8.73 W 02828 5/8 25 250 0.11 10.31 W 02834 3/4 25 250 0.15 10.43 W 02847 1 10 100 0.27 17.77 W 02350 1-1/4 10 100 0.42 26.27 W 02355 1-1/2 5 50 0.6 37.53 W 02359 2 5 25 1.21 61.23 W 02363 2-1/2 5 25 2.08 118.07 W 02368 3 2 10 3.1 184.28 W 02393 3-1/2 1 5 5.52 661.82 W 02395 4 -1 7.5 598.63 90° ELBOW SHORT RADIUS WE-506 FTG x FTG Part Size Box Ctn Wt List W 02612 1/4 50 2800 0.02 12.31 W 02621 3/8 50 750 0.04 13.32 W 02626 1/2 50 500 0.05 6.85 W 02634 3/4 25 250 0.11 15.43 W 02644 1 10 100 0.21 17.86 W 02684 1-1/4 10 100 0.29 23.38 W 02685 1-1/2 5 50 0.44 29.67 W 02686 2 1 10 0.86 61.07 W 02687 2-1/2 1 10 1.38 127.29 W 02688 3 1 10 2.07 138.17 W 02689 3-1/2 1 10 2.63 1,095.85 W 02690 4 1 5 3.88 1,054.82 90° ELBOW LONG RADIUS WE-506L FTG x FTG Part Size Box Ctn Wt List W 02650 1-1/4 5 50 0.41 37.48 W 02655 1-1/2 5 50 0.62 53.99 W 02659 2 1 10 1.19 87.63 FITTING REDUCER WC-403 FTG x C Part Size Box Ctn Wt List W 01306 1/4 x 1/8 50 2000 0.02 2.73 W 01312 3/8 x 1/4 50 2000 0.02 2.75 W 01314 x 1/8 50 2800 0.01 3.48 W 01315 1/2 x 3/8 50 750 0.03 2.29 W 01317 x 1/4 50 1700 0.03 2.54 W 01320 5/8 x 1/2 100 1000 0.03 5.50 W 01321 x 3/8 100 900 0.04 5.56 W 01322 x 1/4 100 900 0.03 5.84 W 01325 3/4 x 5/8 50 500 0.08 3.51 WB01326 x 1/2 25 500 0.06 3.45 W 01327 x 3/8 50 500 0.05 4.54 W 01337 1 x 3/4 25 250 0.11 5.32 W 01338 x 5/8 25 250 0.09 6.45 W 01339 x 1/2 25 250 0.1 6.93 W 01340 x 3/8 20 200 0.08 6.56 W 01343 1-1/4 x 1 10 100 0.17 9.81 W 01345 x 3/4 10 100 0.15 9.81 W 01347 x 1/2 10 100 0.14 9.81 W 01350 1-1/2 x 1-1/4 10 100 0.21 12.78 W 01351 x 1 10 100 0.22 12.78 W 01353 x 3/4 10 100 0.21 12.78 W 01355 x 1/2 10 100 0.21 12.78 W 01358 2 x 1-1/2 -100 0.39 24.07 W 01359 x 1-1/4 -100 0.38 24.07 W 01360 x 1 -100 0.4 25.36 W 01362 x 3/4 -100 0.39 25.36 W 01364 x 1/2 -100 0.44 26.92 W 01367 2-1/2 x 2 -50 50 0.63 47.92 W 01368 x 1-1/2 -50 0.58 48.91 W 01369 x 1-1/4 -50 0.65 49.82 W 01370 x 1 -50 0.73 55.74 W 01376 3 x 2-1/2 -25 0.93 59.84 W 01377 x 2 -25 0.96 58.51 W 01378 x 1-1/2 -50 1.03 65.40 1 2 FITTING REDUCER (CONT.) W 01379 x 1-1/4 -50 1.12 63.95 W 01381 3-1/2 x 3 -20 1.32 85.16 W 01382 x 2-1/2 -20 1.37 85.16 W 01383 x 2 -20 1.49 85.16 W 01386 4 x 3-1/2 -20 1.76 120.90 W 01387 x 3 -15 1.84 122.39 W 01388 x 2-1/2 -15 2.03 127.25 W 01389 x 2 -15 1.81 133.96 W 01390 5 x 4 -1 3.24 710.30 W 01391 x 3 -1 2.76 710.30 W 01393 x 2 -1 2.66 709.32 W 01394 6 x 5 -1 4.8 1,130.48 W 01395 x 4 -1 4.32 1,130.48 W 01396 x 3 -1 4.49 1,130.48 HANGER HI-EAR W-124 C Part Size Box Ctn Wt List A 03167 1/2 100 1000 0.03 6.22 A 03168 3/4 25 500 0.04 9.18 A 03171 1 25 250 0.04 11.53 PLUG FITTING WC-416 FTG (SIZES 1/8 THRU 11/2 BRASS ROD) Part Size Box Ctn Wt List A 01402 1/8 50 500 0.01 10.06 A 01422 1/4 100 4000 0.01 10.06 A 01392 3/8 50 2000 0.02 11.84 A 01504 1/2 50 1200 0.03 15.96 A 02273 5/8 10 560 0.05 11.11 A 01529 3/4 50 600 0.07 11.71 A 01556 1 25 375 0.12 20.76 A 01590 1-1/4 15 180 0.2 27.35 A 01628 1-1/2 10 120 0.28 36.85 RETURN BEND WE-512 C x C Part Size Box Ctn Wt List W 06025 1/4 x 4-1/2 25 150 0.09 8.69 W 06020 x 1-1/2 25 850 0.03 4.96 W 06048 3/8 x 6 -100 0.19 13.38 W 06045 x 4 -200 0.13 6.30 W 06041 x 3 25 250 0.1 6.14 W 06036 x 2 50 300 0.07 6.42 W 06035 x 1-29/32 50 300 0.07 6.14 W 06032 x 1-1/2 50 500 0.06 6.62 W 06069 1/2 x 6 5 30 0.3 16.24 W 06062 x 3-3/8 10 100 0.18 19.14 W 06060 x 3 25 150 0.16 10.84 W 06058 x 2-1/2 25 250 0.13 10.84 W 06056 x 2-1/4 25 250 0.13 20.60 W 06053 x 1-7/8 25 250 0.11 10.84 W 06051 x 1-9/16 25 250 0.1 17.44 W 06084 5/8 x 4 -120 0.23 22.45 W 06081 x 3-3/8 10 90 0.23 22.45 W 06077 x 2-1/2 10 100 0.18 23.15 W 06074 x 2-1/8 10 100 0.16 25.35 W 06073 x 2 10 100 0.16 47.74 W 06099 3/4 x 12 -15 0.88 37.64 W 06095 x 3-3/8 10 100 0.3 26.66 W 06092 x 2-1/2 10 100 0.23 19.13 W 60111 1 x 3-1/4 5 50 0.52 47.71 W 60110 x 3 5 50 0.48 41.52 W 60121 1-1/4 x 3-3/4 5 50 0.73 68.26 W 60131 1-1/2 x 4-4-1/2 5 25 1.04 85.71 W 60140 2 x 5-1/2 5 25 2.07 223.69 P-TRAP SUCTION LINE WE-554P C x C Part Size Box Ctn Wt List W 60999 1/2 10 50 0.36 38.61 W 61008 5/8 10 50 0.45 57.55 W 61000 3/4 5 25 0.58 42.95 W 61001 1 3 15 0.84 65.27 W 61002 1-1/4 4 20 1.16 118.66 W 61003 1-1/2 4 4 2.32 180.18 W 61009 2 -3 3.93 368.83 TEEEE WT-600 C x C x C Part Size Box Ctn Wt List W 40306 1/8 100 2400 0.01 7.65 W 04000 1/4 50 1700 0.02 8.07 W 04001 3/8 50 500 0.05 6.48 WB04006 1/2 50 500 0.06 2.19 W 04017 5/8 25 250 0.12 14.09 WB04031 3/4 25 200 0.17 5.28 WB04048 1 10 100 0.31 16.30 W 04068 1-1/4 5 50 0.5 22.28 W 04084 1-1/2 5 50 0.7 34.34 W 40102 2 5 25 1.6 52.09 W 40123 2-1/2 2 20 2.11 108.05 W 40152 3 2 10 3.79 160.44 W 40190 3-1/2 1 5 5.74 464.64 W 40200 4 1 5 8.1 377.52 W 40400 5 – 1 15.67 1,235.88 W 40500 6 – 1 22 1,689.02 W 40525 8 – 1 36.81 6,520.00 REDUCING W 40368 1/8 x 1/8 x 1/4 50 750 0.03 19.43 W 04016 1/4 x 1/4 x 1/2 50 500 0.09 14.36 W 04005 x 3/8 50 500 0.04 19.00 W 40324 x 1/8 50 1700 0.02 13.05 W 40330 x 1/8 x 1/4 50 500 0.03 17.10 W 40332 x 1/8 50 1700 0.03 17.10 W 04015 3/8 x 3/8 x 1/2 50 500 0.09 12.38 W 04002 x 1/4 50 500 0.04 12.20 W 40350 x 1/8 50 500 0.04 12.20 W 04003 x 1/4 x 3/8 50 500 0.05 19.43 W 04004 x 1/4 50 500 0.05 18.12 W 40358 x 1/8 50 750 0.05 24.12 W 40363 x 1/8 x 3/8 50 750 0.05 22.90 W 40364 x 1/4 50 750 0.05 25.04 W 40366 x 1/8 50 450 0.05 22.90 W 04067 1/2 x 1/2 x 1 10 100 0.33 21.66 W 04047 x 3/4 25 250 0.15 10.13 W 04029 x 5/8 25 250 0.1 37.62 W 04007 x 3/8 50 500 0.08 11.27 W 04008 x 1/4 50 500 0.08 11.27 W 04014 x 1/8 50 500 0.09 13.31 W 04009 x 3/8 x 1/2 50 500 0.08 15.48 W 04010 x 3/8 50 500 0.08 15.75 W 04011 x 1/4 50 500 0.08 14.65 W 04012 x 1/4 x 1/2 50 500 0.09 14.65 W 40367 x 3/8 50 500 0.08 20.37 W 04013 x 1/4 50 500 0.08 14.65 W 04046 5/8 x 5/8 x 3/4 25 250 0.15 21.67 W 04018 x 1/2 25 250 0.12 22.70 W 04019 x 3/8 25 250 0.1 22.70 W 04020 x 1/4 25 250 0.1 22.70 W 04021 x 1/2 x 5/8 25 225 0.17 22.90 W 04022 x 1/2 25 250 0.13 22.90 W 04023 x 3/8 25 225 0.11 26.46 W 04025 x 3/8 x x 5/8 25 250 0.18 24.12 W 04026 x 1/2 25 225 0.14 23.62 W 04027 x 3/8 25 250 0.11 23.62 W 04065 3/4 x 3/4 x 1 10 100 0.28 17.74 W 04032 x 5/8 25 250 0.2 5.93 WB04033 x 1/2 25 250 0.14 5.07 W 04034 x 3/8 25 250 0.14 7.07 W 04035 x 1/4 25 250 0.14 7.22 W 04036 x 5/8 x 3/4 25 250 0.16 12.54 W 04037 x 5/8 25 250 0.17 11.26 WB04041 x 1/2 x 3/4 25 250 0.17 6.22 W 04042 x 5/8 25 150 0.17 7.18 WB04043 x 1/2 25 250 0.14 6.22 W 04044 x 3/8 25 250 0.16 10.47 W 04045 x 1/4 25 225 0.16 10.47 W 40230 x 3/8 x 3/4 25 250 0.16 12.05 W 40231 x 1/2 25 250 0.16 9.63 W 40232 x 3/8 25 250 0.14 11.70 W 40101 1 x 1 x 1-1/2 5 50 0.82 51.46 W 04082 x 1-1/4 5 50 0.44 36.38 WB04049 x 3/4 10 100 0.27 16.36 W 04050 x 5/8 10 100 0.36 24.12 WB04051 x 1/2 10 100 0.23 16.36 W 04052 x 3/8 10 100 0.23 20.04 W 04055 1x3/4x1 10 100 0.24 19.45 W 04056 x 3/4 10 100 0.3 19.45 W 04057 x 5/8 10 90 0.43 22.42 W 04058 x 1/2 10 100 0.22 19.45 W 04059 x 3/8 10 100 0.35 47.34 W 40233 x 5/8 x 1 10 100 0.33 20.42 W 40234 x 3/4 10 90 0.34 22.45 W 40235 x 5/8 10 100 0.35 22.45 W 40236 x 1/2 10 90 0.35 22.45 Copper Fittings -Wrot All sizes are nominal. Page 4 UW CFW0908 Effective September 15, 2008 Copper Fittings -Wrot TEE (CONT.) W 04061 x 1/2 x 1 10 100 0.31 19.45 W 04062 x 3/4 10 100 0.32 20.48 W 04063 x 1/2 10 100 0.36 19.45 W 40122 1-1/4x1-1/4 x2 2 20 1.68 107.21 W 40100 x 1-1/2 5 50 0.72 52.14 W 04069 x 1 5 50 0.49 24.07 W 04070 x 3/4 5 50 0.33 24.07 W 04071 x 1/2 5 50 0.28 24.07 W 04072 x 3/8 5 50 0.29 28.00 W 04073 x 1 x 1-1/4 5 50 0.54 31.62 W 04074 x 1 5 50 0.53 30.90 W 04075 x 3/4 5 50 0.38 30.90 W 04076 x 1/2 5 50 0.57 31.63 W 04078 x 3/4 x 1-1/4 5 50 0.56 30.90 W 04079 x 1 5 50 0.52 33.29 W 04080 x 3/4 5 50 0.36 30.90 W 04081 x 1/2 5 50 0.3 34.54 W 04083 1/2 x 1-1/4 5 50 0.57 31.62 W 40121 1-1/2x1-1/2x2 2 20 1.12 99.79 W 04085 x 1-1/4 5 50 0.68 25.56 W 04086 x 1 5 50 0.48 25.56 W 04087 x 3/4 5 50 0.43 25.56 W 04088 x 1/2 5 50 0.48 25.56 W 04089 x 3/8 5 50 0.76 29.45 W 04090 x1-1/4x1-1/2 5 50 0.78 54.43 W 04091 x 1-1/4 5 50 0.72 52.30 W 04092 x 1 5 50 0.6 51.25 W 04093 x 3/4 5 50 0.6 52.30 W 04094 x 1/2 5 50 0.6 54.43 W W 04095 x 1 x 1-1/2 5 50 0.8 52.30 W 04096 x 1-1/4 5 50 0.73 54.43 W 04097 x 1 5 50 0.68 51.25 W 04098 x 3/4 5 50 0.8 52.30 W 40237 x 1/2 5 30 0.81 54.43 W 04099 x 3/4 x 1-1/2 5 50 0.81 51.25 W 40239 x 1-1/4 5 50 0.75 56.23 W 40240 x 1 5 50 0.81 54.43 W 40238 x 3/4 x 3/4 5 50 0.67 54.43 W 40243 x 1/2 5 50 0.83 57.33 W 40244 x 1/2 x 1-1/2 5 50 0.83 52.41 W 40153 2 x 2 x 3 1 10 2.55 320.55 W 40144 x 2-1/2 1 10 2.41 199.25 W 40103 x 1-1/2 5 50 1.19 41.69 W 40104 x 1-1/4 5 50 1.12 46.29 W 40105 x 1 5 50 0.92 41.69 W 40106 x 3/4 5 50 0.84 40.45 W 40107 x 1/2 5 50 0.85 40.45 W 40108 x 3/8 2 20 0.94 46.75 W 40109 x 1-1/2 x 2 2 20 1.6 69.63 W 40110 x 1-1/2 2 20 1.19 68.11 W 40111 x 1-1/4 2 20 1.34 75.52 W 40112 x 1 2 20 0.95 69.63 W 40113 x 3/4 2 20 0.98 69.63 W 40114 x 1/2 5 50 1.03 71.92 W 40115 x 1-1/4 x 2 2 20 1.87 72.39 W 40116 x 1-1/2 2 20 1.21 74.84 W 40117 x 1-1/4 2 20 1.28 75.52 W 40118 x 1 2 20 0.94 74.84 W 40119 x 3/4 5 50 0.94 74.84 W 40120 x 1/2 5 20 1.13 74.84 W 40245 x 1 x 2 5 25 1.65 69.63 W 40247 x x 1 5 50 0.97 69.63 W 40248 x 3/4 x 2 5 25 1.57 69.63 W 40249 x 1/2 x 2 5 25 1.61 69.63 W 40124 2-1/2 2-1/2 x 2 2 20 1.81 125.97 W 40125 x 1-1/2 2 20 1.87 125.97 W 40126 x 1-1/4 2 20 1.89 125.97 W 40127 x 1 2 20 1.91 125.97 W 40128 x 3/4 1 10 1.94 123.27 W 40129 x 1/2 1 10 1.94 125.97 W 40130 x 2 x 2-1/2 4 20 2.24 162.99 W 40131 x 2 2 20 1.95 157.71 W 40132 x 1-1/2 4 20 2 163.33 W 40133 x 1-1/4 4 20 2.09 169.82 W 40134 x 1 4 20 2.22 169.82 W 40135 x 3/4 4 20 2.23 169.82 W 40136 x 1/2 4 20 2.25 169.82 W 40137 2-1/2x1-1/2x2-1/2 4 20 2.28 169.82 W 40138 x 2 4 20 1.98 196.44 W 40139 x 1-1/2 4 20 2.04 196.44 W 40140 x 1-1/4 4 20 2.05 171.65 W 40141 x 1 4 20 1.83 185.20 W 40142 x 3/4 4 20 2.36 185.20 W 40143 x 1/2 4 20 2.36 185.20 W 40220 x 1-1/4 x 2-1/2 4 20 2.35 179.64 W 40250 x 2 4 20 1.82 179.64 W 40251 x 1-1/2 4 20 2.47 178.73 W 40252 x 1-1/4 4 20 1.96 178.73 W 40253 x 1 4 20 2.47 178.73 W 40254 x 3/4 4 20 2.47 178.73 COPPER TUBE STRAP (CONT.) A 02614 1 50 750 0.02 1.31 A 02650 1-1/4 50 500 0.04 1.57 A 02675 02675 1-1/2 50 500 0.05 1.86 A 02708 2 50 500 0.06 2.08 PERFORATED COPPER STRAP WS-1101 Part Size Box Ctn Wt List A 01211 25 Ft.Roll 1 10 1.63 89.80 SOLDER JOINT DWV FITTINGS ADAPTER TRAP DW-724F FTG x SJ Part Size Box Ctn Wt List A 11564 1-1/2x1-1/2 OD 10 100 0.28 28.38 REDUCING A 11566 1-1/2x1-1/4 OD 10 100 0.26 30.19 ADAPTER TRAP DW-724 C x SJ Part Size Box Ctn Wt List A 11355 1-1/4x1-1/4 OD 25 250 0.22 20.89 A 11356 1-1/2x-1/2 OD 10 200 0.33 22.90 REDUCING A 11383 1-1/2x1-1/4 OD 10 200 0.4 31.46 ADAPTER TRAP DW-757 F x SJ Part Size Box Ctn Wt List A 11409 1-1/4x1-1/4 OD 10 100 0.34 27.96 A 11410 1-1/2x1-1/2 OD 10 100 0.4 34.25 REDUCING A 11411 1-1/2x1-1/4 OD 10 100 0.4 32.62 ADAPTER TRAP DW-756 M x SJ Part Size Box Ctn Wt List A 11405 1-1/4x1-1/4 OD 10 100 0.42 28.60 A 11406 1-1/2x1-1/2 OD 10 100 0.52 30.46 REDUCING A 11407 1-1/2x1-1/4 OD 10 100 0.53 33.68 ADAPTER SOIL PIPE DW-733 C x SPIGOT Part Size Box Ctn Wt List W 07122 2 5 100 0.43 25.43 W 07133 3 5 40 1.12 85.16 EDUCING W 07112 x 2 5 50 0.61 51.46 ADAPTER FEMALE DW-753 C x F Part Size Box Ctn Wt List W 07221 1-1/2 10 100 0.25 16.25 W 07222 2 10 100 0.41 30.35 ADAPTER DW-754 FTG x F Part Size Box Ctn Wt List W 07240 1-1/4 10 100 0.19 34.51 1 2 1 2 1 2 1 2 1 2 1 2 TEE (Cont.) W 40255 x 1/2 4 20 2.47 178.73 W 40221 x 1 x 2-1/2 4 20 2.35 179.64 W 40256 x 2 4 20 1.97 178.73 W 40257 x 1-1/2 4 20 2.15 178.73 W 40258 x 1-1/4 4 20 2.04 178.73 W 40259 x 1 4 20 2.25 178.73 W 40222 x 3/4 x 2-1/2 4 20 3.04 173.09 W 40151 3 x 3 x 2-1/2 2 10 4.18 147.66 W 40150 x 2 2 20 2.27 134.97 W 40149 x 1-1/2 2 10 2.37 134.97 W 40148 x 1-1/4 2 10 2.39 134.97 W 40147 x 1 2 20 1.8 134.97 W 40146 x 3/4 2 20 1.83 134.97 W 40145 x 1/2 2 20 1.83 134.97 W 40159 3 x 2-1/2 x 3 2 10 5.2 233.59 W 40158 x 2-1/2 2 10 3.3 225.66 W 40157 x 2 2 10 2.52 225.66 W 40156 x 1-1/2 2 10 2.61 276.68 W 40155 x 1-1/4 2 10 2.6 228.00 W 40154 x 1 2 20 2.31 325.48 W 40167 x 2 x 3 2 10 4.1 233.59 W 40165 x 2-1/2 2 10 4.36 245.87 W 40164 x 2 2 10 2.54 220.33 W 40163 x 1-1/2 2 10 2.62 325.48 W 40162 x 1-1/4 4 2 10 2.6 325.48 W 40161 x 1 2 20 2.31 325.48 W 40174 x 1-1/2 x 3 2 10 4.25 225.66 W 40181 x 1-1/4 x 3 2 10 5.2 246.52 W 40178 x 1 x 3 2 10 4.4 246.52 W 40179 x 3/4 x 3 2 10 4.28 239.99 W 40198 4 x 4 x 3 1 5 4.92 268.21 W 40197 x 2-1/2 1 5 5.15 290.40 W 40196 x 2 1 10 4.33 254.83 W 40195 x 1-1/2 1 10 4.46 240.94 W 40194 x 1-1/4 1 10 4.39 252.32 W 40193 x 1 1 10 3.25 240.94 W 40192 x 3/4 1 10 3.37 273.11 W 40191 x 1/2 1 10 3.46 266.31 W 40208 x 3 x 4 1 5 8.29 503.52 W 40206 x 3 1 5 5.46 485.74 W 40205 x 2-1/2 1 5 5.61 530.04 W 40204 x 2 1 5 4.65 503.52 W 40212 x 2-1/2 x 4 1 5 8.61 503.52 W 40216 x 2 x 4 1 5 8.75 503.52 W 40215 x 1-1/2 x 4 1 5 8.51 503.52 W 40214 x 1-1/4 x 4 1 5 8.57 503.52 W 40213 x 1 x 4 1 5 9.33 503.52 W 40401 5 x 5 x 4 – 1 6.95 1,235.88 W 40402 x 3 – 1 6.25 1,174.10 W 40404 x 2 – 1 5.05 1,174.10 W 40520 6 x 4 x 4 – 1 12.52 1,782.84 W 40502 x 6 x 4 – 1 11 1,689.02 W 40503 x 3 – 1 10.61 1,689.02 W 40504 x 2-1/2 – 1 11.53 1,604.57 W 40505 x 2 – 1 11.75 1,604.57 W 40526 8 x 8 x 4 – 1 24.06 6,520.04 TEE FITTING WT-600F C x FTG x C Part Size Box Ctn Wt List W 04106 1/2 50 300 0.11 8.45 W 04131 3/4 25 150 0.23 13.19 UNION WC-407 C x C Part Size Box Ctn Wt List W 08001 1/4 25 250 0.12 23.10 W 08002 3/8 25 250 0.11 24.29 W 08003 1/2 25 250 0.17 13.96 W 08004 3/4 25 150 0.37 17.55 W 08005 1 10 100 0.51 29.53 COPPER TUBE STRAP 2-HOLE WS-1100 Part Size Box Ctn Wt List A 01203 1/8 100 4,000 0.01 0.70 A 01278 1/4 100 5,600 0.01 0.70 A 01366 3/8 100 3,400 0.01 0.75 A 02529 1/2 100 1,500 0.01 0.73 A 01467 5/8 100 2,000 0.01 0.75 A 02574 3/4 50 750 0.01 1.23 ++ All sizes are nominal. UW CFW0908 Effective September 15, 2008 Page 5 ADAPTER DW-732 C x M Part Size Box Ctn Wt List A 07012 1-1/4 25 250 0.36 17.86 A 07054 1-1/2 10 100 0.39 19.45 A 07094 2 5 100 0.66 24.64 REDUCING W 07235 1-1/4 x 1-1/2 10 100 0.37 25.33 BUSHING EXTENDED DW-742 FTG x C Part Size Box Ctn Wt List W 07350 1-1/2 x 1-1/4 25 250 0.1 10.92 W 07358 2 x 1-1/2 – 100 0.16 11.96 W 07359 x 1-1/4 – 100 0.21 13.20 W 07377 3 x 2 – 50 0.5 50.67 W 07378 x 1-1/2 – 50 0.58 80.16 W 07379 x 1-1/4 – 50 0.63 45.48 W 07387 4 x 3 – 25 0.89 80.74 W 07389 x 2 – 25 1.38 103.05 CLOSET FLANGE DW-734 C x CLOSET Part Size Box Ctn Wt List W 07834 3 x 4 5 50 0.83 47.59 W 07844 4 x 4 5 40 0.67 83.87 COUPLING DW-741 C x C Part Size Box Ctn Wt List W 07055 1-1/4 25 150 0.07 5.80 W 07063 1-1/2 25 250 0.1 7.21 W 07072 2 – 100 0.16 10.00 W 07092 3 – 50 0.28 18.83 W 70107 4 – 25 0.67 58.32 REDUCING W 07073 2 x 1-1/2 – 100 0.25 13.49 W 07074 x 1-1/4 – 100 0.28 10.95 W 07094 3 x 2 – 50 0.64 42.96 W 07095 x 1-1/2 – 50 0.7 45.03 W W 07096 x 1-1/4 – 50 0.7 45.19 W 70109 4 x 3 – 25 1.16 81.71 W 70106 x 2 – 25 1.03 81.71 REPAIR COUPLING DW-741NS C x C Part Size Box Ctn Wt List W 07907 1-1/4 25 225 0.06 8.47 W 07908 1-1/2 25 250 0.11 8.54 W 07909 2 – 75 0.16 11.70 W 07911 3 – 50 0.42 20.72 45° ELBOW DW-204 C x C Part Size Box Ctn Wt List W 07420 1-1/4 25 250 0.13 11.40 W 07421 1-1/2 25 125 0.2 9.42 W 07422 2 – 50 0.37 21.67 W 07423 3 – 25 1.12 44.73 45° ELBOW (STREET) DW-205 FTG x C Part Size Box Ctn Wt List W 07430 1-1/4 25 250 0.18 17.55 W 07431 1-1/2 25 125 0.25 13.20 W 07432 2 – 50 0.48 26.92 W 07433 3 – 25 1.05 63.01 1 2 90° ELBOW DW-200 C x C Part Size Box Ctn Wt List W 07400 1-1/4 25 125 0.25 12.38 W 07401 1-1/2 20 100 0.36 18.54 W 07403 2 – 50 0.7 24.21 W 07404 3 – 15 1.65 58.26 90° ELBOW LONG TURN D-700LT C x C Part Size Box Ctn Wt List A 07209 1-1/2 5 100 0.41 31.76 A 07202 2 5 40 0.62 44.99 90° ELBOW EXTRA LONG TURN DW-700XLT C x C Part Size Box Ctn Wt List W 07451 1-1/2 10 50 0.56 32.15 W 07452 2 5 25 1.11 45.48 W 07453 3 2 10 2.37 190.98 W 07454 4 – 5 5.04 352.77 90° ELBOW DW-203 FTG x C Part Size Box Ctn Wt List W 07410 1-1/4 25 125 0.4 22.08 W 07411 1-1/2 20 100 0.38 17.21 W 07412 2 – 50 0.68 33.38 W 07413 3 – 15 1.7 69.34 60° ELBOW DW-701 C x C Part Size Box Ctn Wt List W 07064 1-1/2 25 250 0.35 22.35 W 07066 3 2 20 0.95 92.19 22-1/2° ELBOW DW-703 C x C Part Size Box Ctn Wt List W 07060 1-1/2 – 100 0.27 27.21 TEE DW-707 C x C x C Part Size Box Ctn Wt List W 07500 1-1/4 20 100 0.35 24.46 W 07511 1-1/2 20 100 0.61 30.46 W 07522 2 5 25 0.89 35.51 W 07533 3 – 10 2.33 124.98 REDUCING W 07510 1-1/2x1-1/2x1-1/4 10 100 0.51 36.45 W 07512 x1-1/4x1-1/4 10 100 0.51 71.48 W 07521 2 x 2 x 1-1/2 5 50 0.76 33.53 W 07520 x 1-1/4 5 30 0.71 36.76 W 07524 x1-1/2x1-1/2 5 50 0.86 56.68 W 07532 3 x 3 x 2 5 25 1.65 98.40 W 07531 x 1-1/2 5 25 1.51 98.40 W 07530 x 1-1/4 5 25 1.41 98.40 21 3 1 2 TEST CAP DW-798T C Part Size Box Ctn Wt List W 07634 1/2 500 5,000 0.03 1.10 W 07635 3/4 200 4,000 0.01 1.24 W 07636 1 100 2,000 0.01 2.21 W 07637 1-1/4 100 2,000 0.02 2.21 W 07638 1-1/2 100 1,000 0.02 2.23 W 07639 2 50 1,000 0.04 4.79 W 07640 3 25 250 0.07 9.55 VENT INCREASER DW-752 C x TUBE Part Size Box Ctn Wt List W 70112 3 x 4 x 18 – 6 4.37 251.81 W 70111 3 x 4 x 24 – 5 5.91 285.36 21 Copper Fittings -Wrot SOLDER JOINT DWV FITTINGS Page 6 UW CFW0908 Effective September 15, 2008 Copper Fittings -Wrot VALVES a company TM ZURN DOCUMENT #: REVISION: BF-975XL(lg) 6/09 SPECIFICATION SUBMITTAL SHEET Page 1 of 2 Model 975XL Reduced Pressure Principle Assembly WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com FEATURES Sizes:  3/4"  1"  1 1/4"  1 1/2"  2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 OPTIONS (Suffixes can be combined)  -with full port QT ball valves (standard)  L -less ball valves  U -with union ball valves  MS -with integral relief valve monitor switch  P -for reclaimed water systems  S -with bronze "Y" type strainer  BMS -with battery operated monitor switch  FDC -with fire hydrant connection; 2" only  TCU -with test cocks up  V V -with union swivel elbows (3/4" & 1")  SE -with street elbows  FT -with integral male 45° flare SAE test fitting ACCESSORIES  Air gap (Model AG)  Repair kit (rubber only)  Thermal expansion tank (Model XT)  Soft seated check valve (Model 40XL)  Shock arrester (Model 1250)  QT-SET Quick Test Fitting Set  Ball valve handle locks  Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. STANDARDS COMPLIANCE ● ASSE® Listed 1013 ● IAPMO® Listed ● UL® Classified (less shut-off valves or with OS&Y valves) ● C-UL® Classified ● CSA® Certified ● AWWA Compliant C511 ● Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California ● NYC MEA 425-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA Approved) Buna Nitrile (FDA Approved) Polymers Noryl™, NSF Listed Springs Stainless steel, 300 series Relief Valve discharge port: 3/4” -1” -0.63 sq. in. 1 1/4” -2” -1.19 sq. in. MODEL SIZE DIMENSIONS (approximate) WEIGHT A A UNION BALL VALVES B LESS BALL VALVES C D E F G LESS BALL VALVES WITH BALL VALVES in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs kg lbs. kg 3/4 20 12 305 13 3/4 349 7 3/4 197 2 1/8 54 3 76 3 1/2 89 5 127 16 1/8 410 10 4.5 12 5.5 1 25 13 330 14 1/2 368 7 3/4 197 2 1/8 54 3 76 3 1/2 89 5 127 17 3/8 441 10 4.5 14 6.4 1 1/4 32 17 432 18 13/16 478 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 22 9/16 573 22 10 28 12.7 1 1/2 40 17 3/8 441 19 3/8 492 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 24 1/16 611 22 10 28 12.7 2 50 18 1/2 470 20 1/2 521 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 26 1/2 673 22 10 34 15.4 AB G D C FE Page 2 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com 0 20 40 60 80 5 10 15 20 0 50 100 150 200 250 5 10 15 20 Rated Flow (Established by approval agencies) FLOW RATES (GPM) PRESSURE LOSS (PSIG) 69 PRESSURE LOSS (kpa) FLOW RATES (l/s) MODEL 975XL 3/4", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) 35 3/4" (20mm) 1" (25mm) 1 1/4" (32mm) 2" (50mm) 103 1.26 2.52 3.8 5.0 3.2 6.3 9.5 12.6 15.8 1 1/2” (40mm) 137 TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturers’ instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12” (305mm) and a maximum of 30” (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. INDOOR INSTALLATION OUTDOOR INSTALLATION (*Shown w/optional BMS) SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180°F and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed Noryl™ and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2" 5 7 9 14 3/4" 8 12 17 25 1" 13 20 27 40 1 1/4" 23 35 47 70 1 1 1/2" 32 48 63 95 2" 52 78 105 167 BATTERY MONITOR SWITCH* AIR GAP FITTING 12" MIN. 30" MAX. FLOOR DRAIN DIRECTION OF FLOW FLOOR CENTRAL STATION ALARM PANEL 12" MIN 30" MAX PROTECTIVE ENCLOSURE OPTIONAL WATER METER INLET SHUT-OFF AIR GAP DRAIN DIRECTION OF FLOW FLOW CHARACTERISTICS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 18 A H E A D O F T H E F L O W™ www.nibco.com Revised 8/01/03 300 lb. WWP Bronze Ball Valves Fire Protection Valve • Two-Piece Body • Chrome Plated Ball • Blowout-Proof Stem • Reinforced TFE Seats MATERIAL LIST PART SPECIFICATION 1. Handle Nut Zinc Plated Steel 2. Handle Zinc Plated Steel Clear Chromate with Plastisol Grip 3. Threaded Pack Gland Brass ASTM B 16 4. Packing TFE 5. Stem Silicon Bronze ASTM B 371 Alloy C69430 or ASTM B 99 Alloy C65100 6. Thrust Washer Reinforced TFE 7. Ball Brass ASTM B 124 Alloy C37700 or ASTM B 16 Alloy C36000 with Hard Chrome Plate 8. Seat Ring (2) Reinforced TFE 9. Body Cast Red Bronze ASTM B 584 Alloy C84400 10. Body End Piece Cast Red Bronze ASTM B 584 Alloy C84400 ¹⁄₄" and ³⁄₈ " size only has a 304 stainless steel grounding washer. 300 PSI/20.7 Bar Non-Shock Cold Water CONFORMS TO MSS SP-110 • UL LISTED† • FMRC APPROVED† DIMENSIONS—WEIGHTS—QUANTITIES KT-585-70-UL Dimensions Size A B C D Port Weight Box Master In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn. Qty. ¹⁄₄ 8 2.00 51 1.75 44 5.00 127 .38 10 .45 .20 10 100 ³⁄₈ 10 2.00 51 1.75 44 5.00 127 .38 10 .45 .20 10 100 ¹⁄₂ 15 2.44 62 1.88 48 5.19 132 .50 13 .64 .29 10 100 ³⁄₄ 20 2.94 75 2.25 57 6.25 159 .75 19 1.33 .60 5 50 1 25 3.34 85 2.38 59 6.44 164 1.00 25 1.79 .81 5 20 KT-580-70-UL Dimensions Size A B C D Port Weight Box Master In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn. Qty. 1 ¹⁄₄ 32 3.94 100 2.63 67 6.75 171 1.00 25 2.17 .99 5 20 1 ¹⁄₂ 40 4.31 110 3.00 76 8.91 228 1.25 32 3.27 1.49 5 20 2 50 4.63 117 3.25 83 9.06 230 1.50 38 5.09 2.31 5 10 2 ¹⁄₂ 65 5.84 148 3.53 90 9.66 245 2.00 51 8.25 3.79 2 6 3 80 7.09 202 4.41 112 11.53 293 2.50 64 15.65 7.11 1 4 † UL Listed, FMRC Approved for trim and drain use – sizes ¹⁄₄" thru 2". KT-585-70-UL Full Port NPT x NPT KT-580-70-UL Standard Port NPT x NPT KT-585-70-UL ¹⁄₄" -1" Full Port Threaded KT-580-70-UL 1¹⁄₄" -3" Standard Port Threaded Dezincification Resistant United Brass Works, Inc. 714 South Main Street Randleman, NC 27317 USA Phone: 336-498-2661 Fax: 336-498-4267 Toll-free: 800-334-3035 Email: sales@ubw.com Website: http://www.ubw.com All Categories > Industrial Valves > Industrial Swing Check Valves > Model 62 Swing Check Valve > View Items Model 62 Swing Check Valve Check up to five results to perform an action. Complies with MSS-SP-80-97 200WSP at 406° Max 400 WOG 100% Pressure Tested Threaded Ends CRN OCO7135.2C *Contains lead. Not for use in water systems intended for human consumption* Install in horizontal position with cap in upright position. Not recommended for pulsating or vibrating service. When used on Boiler feed line it is recommended that a #50T spring loaded check valve be used in conjunction with #62 with the #62 located nearest to the boiler and the #50T located nearest to the pump. larger image larger image Results 1 -9 of 9 1 Item # Size A -Total Length B -Height Ship Weight Quantity per Carton Model 62 -1/4" 1/4 in 2.38 in 1.53 in 0.75 lb 12 Model 62 -3/8" 3/8 in 2.53 in 1.53 in 0.81 lb 12 Model 62 -1/2" 1/2 in 2.66 in 1.53 in 0.76 lb 12 Model 62 -3/4" 3/4 in 3.09 in 1.88 in 1.19 lb 12 Model 62 -1" 1 in 3.53 in 2.09 in 1.73 lb 6 Model 62 -1 1/4" 1-1/4 in 5.13 in 3.63 in 5.75 lb 2 Model 62 -1 1/2" 1 1/2 in 5.13 in 3.63 in 5.75 lb 2 Model 62 -2" 2 in 5.56 in 4.56 in 10.00 lb 1 Model 62 -3" 3 in 9.13 in 5.58 in 29.00 lb 1 Results 1 -9 of 9 1 United Brass Works, Inc. -Model 62 Swing Check Valve Page 1 of 1 http://ubw.thomasnet.com/printitems/industrial-swing-check-valves/model-62-swing-chec... 8/12/2010 Reliable Riser – Residential Bulletin 416 Rev.D Bulletin 416 Rev.D The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Features: 1. Stainless Steel body construction. 2. All brass trim. 3. Factory assembled. 4. Factory pressure tested at 200 psi. (13.8 bar). 5. Choice of trim: Basic Trim (Fig.1). Basic Trim with Pressure Relief Kit (Fig. 2). Basic Trim with TestANDrainValve (Fig. 3). Basic Trim with TestANDrainValve and Pressure Relief Kit (Fig. 4). 6. Choice of mounting options: Supply /System lines support. Support Bracket (to stud) (Figs. 5 & 6). Recessed or Flush mount (to wood panel) (Fig. 7). 7. NPT (female x female) or tapered metric (female x female) connections. 8. Slim design allows for easy installation within 2x 4on 16centers wood frame construction. 9. Dedicated UL Listed and ULC Listed Water Flow Detector assures optimum sensitivity. Water FlowDetector is factory installed with a metallic,weatherproof cover. Triggering flow rate is 4(15) GPM(LPM) to 10(10(38) GPM(LPM). Fig. 1 Base Trim Fig. 2 Base Trim with Pressure Relief Kit Fig. 4 Base Trim with TestANDrainValve & Pressure Relief Kit Approvals & Listings 1. Listed by Underwriters Laboratories Inc. and ULC Listed. 2. NYC MEA 258-93-E Fig. 3 Base Trim with TestANDrainValve Reliable Riser -Residential 1(25mm), 112(40mm), and 2(50mm) sizes. For use in NFPA 13D and 13R Residential Systems Description Basic Trim Basic Trim with Pressure Relief Kit Basic Trim with TestANDrainValve Basic Trim with TestANDrainValve & Pressure Relief Kit Take Out Manifold Dimension Size: Dimensions Weight* Dimensions Weight* Dimensions Weight* Dimensions Weight* A inch (mm) B inch (mm) Lbs (kgs) A inch (mm) B inch (mm) Lbs (kgs) A inch (mm) B inch (mm) Lbs (kgs) A inch (mm) B inch (mm) Lbs (kgs) C inch (mm) 1(25mm) 11 (279) 912 (241) 7.5 (3.4) 13 (330) 11 (279) 9.5 (4.3) 11 (279) 1012 (267) 8.8 (4.0) 13¾ (349) 1112 (292) 9.8 (4.4) 8 14 (210) 112(40mm) 11 (279) 10 (254) 8.5 (3.85) 13 (330) 1112 (292) 10.5 (4.75) 11 (279) 1114 (286) 9.5 (4.3) 13¾ (349) 12 (305) 10.4 (4.7) 8 14 (210) 2(50mm) 11 (279) 1012 (264) 9.0 (4.1) 13 (330) 12 (305) 11.9 (5.0) 11 (279) 12 (305) 10.3 (4.7) 13¾ (349) 1212 (318) 11.4 (5.2) 8 14 (210) Optional Trims -Technical Data: Product Description: The Reliable-Risers come factory assembled with all of the necessary accessories for a cost effective, yet complete riser solution. Reliable-Rises Rises are [UL Listed][ULC Listed] [NYC Approved MEA 258-93-E] for horizontal or vertical installations as a one-piece, factory assembled unit for use in NFPA 13D and 13R residential systems. The riser manifold assembly shall consist of a (choose one): 1(25 mm) cast, non-welded stainless steel body with 1female NPT or ISO7-Rc1-11 threaded end connections. All Reliable Risers have a 1NPT drain port. * Support Bracket Kit (optional) -1 lb (0.45 kg) 2. 1-12(40 mm) cast, non-welded stainless steel body with 1-12female NPT or ISO7-Rc1.5-11 threaded end connections. 2(50 mm) cast, non-welded, stainless steel body with 2female NPT or ISO7-Rc2-11 threaded end connections. All of these manifold sizes have cast-on lettering that clearly identifies the manifold's pipe size, flow direction, UL Listing/ULC Listing, and the test and drain outlet. A built-in drain port is included to permit hydrostatic testing without draining the system. The assembly has a working pressure rating of 175 Fig. 5 3. Fig.6 psi (12.1 bar). Cast-in mounting holes are provided for recessed or flush mounting to a wall. For stud mounting, a support bracket is available that is specifically designed for the cast mounting holes. All of the trim variations include brass components, a cULus Listed 300 psi water pressure gauge, and a 250 psi rated UL Listed/ULC Listed Waterflow Detector. This Waterflow Detector comes factory installed with a weatherproof (outside) cover. Trim Descriptions Basic Trim Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @125/250 VAC/2.5 A @24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Basic Trim with Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @125/250 VAC/2.5 A @24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM).Pressure relief valve kit shall be provided to maintain system pressures below 175 psi (12.1 bar). Basic Trim with TestANDrainValve Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a TestANDrainvalve, and a dedicated waterflow detector containing two sets of SPDT (FormC) contacts, having an electrical rating of 10A@125/250 VAC/2.5 A@24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). The test orifice size for the TestANDrainassembly shall be (choose one): 3 8(10 mm) 716(11 mm) ½(15 mm) -See Bulletin 425 Basic Trim with TestANDrainValve & Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a TestANDrainvalve, and a dedicated waterflow detector containing two sets of Fig.7 SPDT (FormC) contacts, having an electrical rating of 10A@125/250 VAC/2.5 A@24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Pressure Relief Kit shall be provided to maintain system pressures below 175 psi (12,1 bar). Installation: 1. Install the manifold with the flow arrow pointing towards SYSTEM side using threaded connections. 2. Connect a 1NPT drain line. Ensure the drain Ball Valve is in the CLOSED position. 3. Place the sprinkler system in service. Caution: Automatic sprinkler systems having non-fire protection connection (permitting continual water flow) require dielectric fittings, according to NFPA 13 sect. 4-6, when dissimilar metal piping materials are joined. Note: Use a non-hardening pipe joint compound, or tape. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by themost highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431–1588 Sales Offices (800) 848–6051 Sales Fax (914) 829–2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data E.G. Printed in USA 6/09 P/N9999970207 Residential Riser Part Number Code Key Ordering Information: 1N 1M 1.5N 1.5M 2N 2M 1N = 1" (25mm) NPT Threaded Ends Assembly 1M = 1" (25mm) Metric Threaded Threaded Ends Assembly 1.5N = 1-1/2" (40mm) NPT Threaded Ends Assembly 1.5M = 1-1/2" (40mm) Metric Threaded Ends Assembly 2N = 2" (50mm) NPT Threaded Ends Assembly 2M = 2" (50mm) Metric Threaded Ends Assembly B T38 T716 B = Basic TrimAssembly T38=BasicTrim Assemblywith 3/8"(10mm) Orif.Test&DrainValve T716=BasicTrim Assemblywith 7/16"(11mm) Orif.Test&DrainValve Note: T12 (12"Orifice ) See Bulletin 425 0123 0 = Assembly without Pressure Relief Kit Water Detector -UL & FM Approved 1 = Assembly with Pressure Relief Kit Water Detector -UL & FM Approved 2 = Assembly Without Pressure Relief Kit Waterflow Detector -ULC Approved 3 = Assembly with Pressure Relief Kit Waterflow Detector -ULC Approved – – Example #1: 1.5N – B – 1 (1-1/2" (40mm) Residential Riser Assembly with NPT Female Inlet and Outlet Threads, Basic Trim with installed Pressure Relief Kit). Example #2: 2M – 716 – 0 (2" (50mm) Residential Riser Assembly with Metric Female Inlet and Outlet Threads, Basic Trim with TestANDrainValve having a 716" Drameter Test Orifice.) Also, If Required: Description Part Number Pressure Relief Kit (For Basic Trim) 98020076 Pressure Relief Kit (For Basic Trim with TestANDrainValve ) 6501203550 Support Bracket Kit 6899190001 Waterflow Detector (RFDTH) 96556910 Waterflow Detector ULC (RFDTHA) 96556914 Paddle Tree -Waterflow Detector 96556911 ELECTRICAL The System Sensor WFDTH Retard T-Tap Waterflow Detector is designed for primary signaling in residential systems and fits within 2x4 stud wall construction. The model fits any tee that has a 1″ NPT branch, including: 1″, 11⁄4″ and 11⁄2″ NPT threaded ferrous and brass tees; 1″, 11⁄4″, 11⁄2″ and 2" copper sweat tees; Central, Spears®, and Victaulic® brand 1″ CPVC tees; and 11⁄2″ polybutylene tees. For 2” cast and malleable threaded tees use 2” paddle (P02-0023-000) provided. Design. The design of the WFDTH makes it easy to install and simple to maintain. It can be mounted in the vertical or horizontal position. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism and switch assembly are field-replaceable. Features. Twelve different flexible paddles fit 1″, 11⁄4″, 11⁄2″ and 2″ tees. Sizes are marked clearly on the paddle for ease of installation. Plastic paddles slip over the actuating lever and are securely fastened with one screw. The handy depth gauge insures the proper installation depth and clearance of the detector to the tee. Construction. The WFDTH includes a durable and tamper resistant enclosure. Its sealed retard assures that the delay mechanism is not contaminated by dust and dirt when the cover is removed. The long lasting cover completely encloses the electrical components to further keep out dust and dirt. Improved self-guiding security screws and removal tools make detectors resistant to tampering and simplify field maintenance. Designed for use in residential sprinkler systems Sealed Retard mechanism (Model WFDTH) assures that the retard is not contaminated by dust and dirt when the cover is removed Visual switch activation permits installer to accurately set the retard even under extremely noisy conditions Rugged, dual SPDT switches are enclosed in a durable terminal block for added strength Accommodates up to 12 AWG wire 100% synchronization fires both alarm panel and local bell simultaneously Models Available WFDTH Waterflow Detector WFDTHA Waterflow Detector (ULC/Canadian) Replacement Parts A77-01-02 Terminal Block A3008-00 Retard Mechanism PRK9 Paddle Kit S07-66-02 Tamper Screws for Cover WFDW Tamper Proof Wrench for Cover C58-164-01 Metal Cover Product Overview WFDTH Water flow Detector WFDTH Waterflow Detector System Sensor Sales and Service ©2003 System Sensor. The company reserves the right to change product specifications without notice. A05-0941-004•8/01•#1052 Spears® is a registered trademark of the Spears Manufacturing Company. Victaulic® is a registered trademark of the Victaulic Company of America. Engineering Specifications Model shall be a WFDTH as manufactured by System Sensor. T-tap waterflow detectors shall be installed on a tee that has a 1″ NPT branch including: 1″, 11⁄4″, or 11⁄2″ threaded ferrous or brass tee; 1–2″ copper sweat tees; Central, Spears®, and Victaulic® brand 1″ CPVC tees; or 11⁄2″ polybutylene tee as designated on the drawings and/or as specified herein. For 2” cast and malleable threaded tees use 2” paddle (P02-0023-000) provided. Detectors shall mount on any clear pipe span of the appropriate size, either a vertical or horizontal run at least 6" from any fittings or valves which may change water direction, flow rate, or pipe diameter or no closer than 24″ from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 250 psi. The retard t-tap detector shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through the tee fitting and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances (one of which is a knockout type) for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. WFDTH is listed by Underwriters Laboratories for indoor use. Ordering Information Part Number Description WFDTH* Waterflow Detector, Fits 1″, 11⁄4″, 11⁄2″ ferrous and brass threaded tees; 1″, 11⁄4″, 11⁄2″, 2″ copper sweat tees; 1″ CPVC tees; and 11⁄2″ polybutylene tees A77-01-02 Replacement Terminal Block for WFDTH A3008-00 Replacement Retard Mechanism PRK9 Replacement Paddle Kit — 12 paddles for WFDTH (see WFDTH for sizes included) S07-66-02 Replacement Tamper Screws for Covers of WFDTH WFDW Replacement Tamper Proof Wrench for Cover of WFDTH C58-164-01 Replacement Metal Cover *ULC version designated with “A” suffix (WFDTHA). Standard Specifications Static Pressure Rating 250 PSI (max.) Triggering Threshold Bandwidth (Flow Rate) 4 to 10 GPM Maximum Surge 18 FPS Compatible Tee Fittings Threaded ferrous and brass tees, copper sweat tees, CPVC tees, and polybutylene tees Contact Ratings 2 sets of SPDT (Form C) 10.0 A @125/250 VAC 2.5 A @24 VDC Overall Dimensions, Installed 4.5″ H x 3.55″ W x 6.7″ L (11.4cm H x 9cm W x 17cm L) Conduit Entrances Two openings for 1⁄2″ conduit Operating Temperature Ranges 32°F – 120°F (0°C – 49°C) Cover Tamper Switch Canadian models only, factor y installed Enclosure UL listed for indoor use Shipping Weight 2.6 lbs. Service Use Automatic Sprinkler: NFPA 13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA NFPA 72 Warranty 3 years U.S. Patent Numbers 3,845,259 4,782,333 5,213,205 Top View Switch 1 COM COM A B B A Switch 2 NOTE: Ccwpo Electrical Connections CONTACT RATINGS 125/250 VAC 24 VDC 10 AMPS 2.5 AMPS WFDTH B B COM COM WFDTH B B COM COM ting ACP To nonsilenceable initiating End of line resistor zone of listed FACP Typical FACP Connection B COM o power source compatible with bell local bell Typical Local Bell Connection To power source compatible with bell WFDTH Switch Assembly Common and B connections will close when vane is deflected, i.e., when water is flowing. Dual switches permit applications to be combined on a single detector. Break wire as shown for supervision of connection. Do not allow stripped wire leads to extend beyond switch housing. Do not loop wires. 0 1 2 3 4 15 30 5 45 55 70 Dial setting Delay (seconds) 0 1 2 3 4 5 2 3 0 1 4 5 15 30 45 55 70 ON NUMBER DIAL TIME APPROXIMATE DELAY (SECONDS) Table of dial settings embossed here (see below) Delay adjustment dial 0 0 Delay Adjustment Dial { System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800-SENSOR2 Fx: 630/377-6495 Documents On Demand: 1-800-736-7672 x3 Web: www.systemsensor.com System Sensor in Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor in Europe Ph: + 44.1403.276500 Fx: + 44.1403.276501 System Sensor in China Ph: + 86.29.524.6253 Fx: + 86.29.524.6259 System Sensor in Singapore Ph: + 65.273.2230 Fx: + 65.273.2610 System Sensor in the Far East Ph: + 852.21919003 Fx: + 852.27366580 System Sensor in Australia Ph: + 613.54.281.142 Fx: + 613.54.281.172 System Sensor in India Ph: + 91.11.526.2119 Fx: + 91.11.527.6815 Agency Listings Features • Electrically compatible with existing SpectrAlert products • Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela • Plug-in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185 • Same mounting plate for wall-and ceiling-mount units • Shorting spring on mounting plate for continuity check before installation • Tamper resistant construction • Outdoor wall and ceiling products rated from –40°F to 151°F • Design allows minimal intrusion into the back box • Horn rated at 88+ dbA at 16 volts • Rotary switch for horn tone and three volume selections • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements • Outdoor products NEMA 4X rated • Compatible with MDL sync module The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product’s tabs in the mounting plate’s grooves. The device will rotate into position, locking the product’s pins into the mounting plate’s terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert® Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. 3023572 MEA452-05-E 7125-1653:186 (indoor strobes) 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn/strobes, chime/strobes) 7135-1653:189 (horns, chimes) S4011 S5512 S3593 A05-0395-005 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature –40°F to 151°F (–40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Wall mount dimensions (including lens) 5.6˝L × 4.7˝W × 2.5˝D (142 mm L × 119 mm W × 64 mm D) Horn dimensions 5.6˝L × 4.7˝W × 1.3˝D (142 mm L × 119 mm W × 33 mm D) Wall-mount back box skirt dimensions (BBS-2, BBSW-2) 5.9˝L × 5.0˝W × 2.2˝D (151 mm L × 128 mm W × 56 mm D) Ceiling-mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1˝ diameter × 2.25˝ high (180 mm diameter × 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB) 5.7˝L × 5.1˝W × 2.0˝D (145 mm L × 130 mm W × 51 mm D) Ceiling-mount weatherproof back box dimensions (SA-WBBC) 7.1˝ diameter × 2.0˝ high (180 mm diameter × 51 mm high) Wall-mount trim ring dimensions (TR-HS, TRW-HS) 5.7˝L × 4.812˝W × 0.35˝D (146 mm L × 122 W mm × 9 D mm) Ceiling-mount trim ring dimensions (TRC-HS, TRCW-HS) 6.9˝ diameter × 0.35 high (176 mm diameter × 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-005 Horn and Horn/Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24 Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-temporal High 82 82 88 88 93 92 100 100 5 Non-temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 7† Coded High 82 82 88 88 93 92 101 101 8† Coded Medium 78 78 85 85 90 90 97 98 9† Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn/strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15* 123 128 66 71 15/75* 142 148 77 81 30* NA NA 94 96 75* NA NA 158 153 95* NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output Data UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 15/75 Do not use below 32°F 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0395-005 • 8/08 • #2018 SpectrAlert Advance Dimensions Model Description Wall Horn/Strobes P2R*† 2-wire Horn/Strobe, Standard cd‡, Red P2RH* 2-wire Horn/Strobe, High cd, Red P2RK*¤ 2-wire Horn/Strobe, Standard cd, Red, Outdoor P2RHK¤ 2-wire Horn/Strobe, High cd, Red, Outdoor P2W* 2-wire Horn/Strobe, Standard cd, White P2WH* 2-wire Horn/Strobe, High cd, White P4R* 4-wire Horn/Strobe, Standard cd, Red P4RH* 4-wire Horn/Strobe, High cd, Red P4RK¤ 4-wire Horn/Strobe, Standard cd, Red, Outdoor P4RHK¤ 4-wire Horn/Strobe, High cd, Red, Outdoor P4W* 4-wire Horn/Strobe, Standard cd, White P4WH* 4-wire Horn/Strobe, High cd, White Wall Strobes SR*† Strobe, Standard cd, Red SRH*† Strobe, High cd, Red SRK¤ Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn/Strobes PC2R* 2-wire Horn/Strobe, Standard cd, Red PC2RH* 2-wire Horn/Strobe, High cd, Red PC2RK¤ 2-wire Horn/Strobe, Standard cd, Red, Outdoor PC2RHK¤ 2-wire Horn/Strobe, High cd, Red, Outdoor PC2W*† 2-wire Horn/Strobe, Standard cd, White PC2WH*† 2-wire Horn/Strobe, High cd, White PC4R 4-wire Horn/Strobe, Standard cd, Red PC4RH 4-wire Horn/Strobe, High cd, Red PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK¤ 4-wire Horn/Strobe, High cd, Red, Outdoor Model Description Ceiling Horn/Strobes (cont’d.) PC4W 4-wire Horn/Strobe, Standard cd, White PC4WH 4-wire Horn/Strobe, High cd, White Ceiling Strobes SCR* Strobe, Standard cd, Red SCRH* Strobe, High cd, Red SCRK¤ Strobe, Standard cd, Red, Outdoor SCRHK¤ Strobe, High cd, Red, Outdoor SCW*† Strobe, Standard cd, White SCWH*† Strobe, High cd, White Horns HR Horn, Red HRK¤ Horn, Red, Outdoor HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White TRC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2R-P. † Add “-SP” to model number for “FUEGO” marking on cover, e.g., P2R-SP. ‡ “Standard cd,” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd,” refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in “K” include a weatherproof back box. ¤ Add “-R” to model number for weatherproof replacement device (no back box included). 4.7˝ 5.6˝ 6.8˝ Dia. 2.5˝ 2.5˝ 5.05˝ 2.23˝ 5.98˝ 7.1˝ Dia. 2.25˝ 5.1˝ 2.0˝6.2˝ 7.1˝ Dia.2.0˝ Wall-mount horn/strobes Ceiling-mount horn/strobes Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box PRINTED IN USA RBVS UNIVERSAL BALL VALVE SWITCH MFG.# 5401086 -REV U PAGE 1 OF 2 5/08 US Patent No. 6,945,509 General The Model RBVS is designed to monitor the fully open position of a ball valve installed in a sprinkler system. The unit will fi t on most ball valves installed on back-fl ow-preventers and alarm trim lines of dry, alarm, and deluge sprinkler valves. The switch operates if the ball valve handle is moved from the open position. However, the switch does not track the position of the handle or ball. When the ball valve handle is in the open position, a spring-loaded switch button will contact the valve handle. When the handle is moved from the open position, this switch button extends to the tripped position, and the RBVS contacts change state, thereby opening or closing a circuit. A cover tamper switch is available and is activated by the removal of the RBVS housing cover. If an attempt is made to remove the RBVS by the removal of the mounting brackets, the unit will be set into the tripped mode by this action. The RBVS can be mounted to the hex portion of the ball valve or back-fl owpreventer or to the adjoining pipe via two clamps. The RBVS is shipped with two sets of mounting clamps to accommodate various pipe and valve sizes, refer to Table 1. An "L" shaped and offset bracket for mounting the switch enclosure and an extension bracket add to the mounting fl exibility of the RBVS. See "Typical Mounting Diagram" and "Installation and Operation" on following page. Testing The RBVS and its associated protective monitoring system should be tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). UL and cUL Listed, FM, CSFM Approved Dimensions: (including mounting clamps) Large Clamps: 6" L x 5" W x 5.2" H 15,2 cm L x 12,7 cm W x 13,2 cm H Small Clamps: 6" L x 4" W x 5.2" H 15,2 cm L x 10,2 cm W x 13,2 cm H Weight: With Large Clamps: 13.6 oz. (386,9 g.) With Small Clamps: 11.0 oz. (311,2 g.) Enclosure: Non-Corrosive Composite Material Environmental Limitations: • NEMA 4 rated enclosure when proper electrical fi ttings are used. (IP67) • Temperature range: -40°F to 150°F (-40°C to 65°C) • Not for use in hazardous locations Housing Cover Tamper: Activated by housing cover removal (Stock No. 1000035 only) Contact Ratings: SPDT Contacts: 10A at 125/250 VAC 2A at 30 VDC SPDT Cover Tamper: 3A at 250 VAC Fig.1 Internal Components Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com RBVS Stock No. 1000040 (w/o Cover Tamper) RBVS-T Stock No. 1000035 (w/Cover Tamper) Installation On Lever Handle (See Fig. 2) 1. Select clamps and clamping bolts based upon pipe/valve size, see Table 1. 2. Insert rubber clamp grippers into clamps, see Fig. 2. 3. Place one clamp on top of pipe/ball valve near the valve handle and insert clamping bolts through it. 4. Place other clamp over clamping bolts from beneath the installation and thread thread hex nuts onto the clamping bolts, but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). (NOTE: Some installations may require one of the mounting bolts to be inserted from the bottom of the brackets and then trimmed to allow the extension bracket to clear. See Fig. 4) 5. Attach extension bracket (if necessary to use for positioning) to top clamp using ¼-20 X ¾" Hex bolt and washer, but do not fully tighten. 6. Attach "L" bracket (RBVS switch enclosure is loosely attached to "L" bracket) to extension bracket using ¼-20 X ¾" Hex bolt and washer, but do not fully tighten. 7. Be sure ball valve is in the fully open position. 8. Slide loosely assembled RBVS switch enclosure to a position that permits the switch button to contact the valve handle approximately 1" from its inside end. See Fig. 1 for approximate location. Cut and remove the plastic coating from the ball valve handle to allow the RBVS switch button to contact (and be activated by) the metal of the handle. 9. Tighten clamping screws alternately to an eventual 30 in-lbs. (minimum) of torque. 10. Maintain position of switch enclosure over valve handle and secure bolt that holds the extension bracket to the clamping assembly. It may be necessary to close valve to access this bolt. 11. Position "L" bracket so that it contacts the back edge of the valve handle, and secure its bolt. It may be necessary to close valve to access this bolt. 12. With the actuator fully retracted, position RBVS switch enclosure to contact the valve handle squarely, see Fig. 1. 13. With RBVS switch enclosure held squarely in contact with valve handle, securely tighten the two tamper resistant screws on the backside of the enclosure. 14. Close and open the valve to verify operation. The actuator should easily retract when the valve handle is in the open position. 15. Fully open the valve. 16. Remove the cover and wire main switch and tamper switch if applicable. Carefully route tamper switch wires through strain relief channel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1. 17. Replace RBVS switch enclosure cover and securely tighten cover screw. PRINTED IN USA RBVS UNIVERSAL BALL VALVE SWITCH MFG.# 5401086 -REV U 5/08 PAGE 2 OF 2 OUTGOING INCOMING DWG# 923-3 Installation on Tee Handle (See Fig. 3) 1. Select clamps and clamping bolts based upon pipe/valve size, see Table 1. 2. Insert rubber clamp grippers into clamps, See Fig. 3. 3. Place one clamp on top of pipe/ball valve near the valve handle and insert clamping bolts through it. 4. Place other clamp over clamping bolts from beneath the installation and thread hex nuts onto the clamping bolts, but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). 5. Loosely attach "L" bracket to the "offset" bracket and "offset" bracket to the RBVS housing. 6. Be sure ball valve is in the fully open position. 7. Slide loosely assembled RBVS switch enclosure to a position that permits the switch button to contact the valve handle approximately 1/2" from the end of the handle. Cut and remove the plastic coating from the ball valve handle to allow the RBVS switch button to contact (and be be activated by) the metal of the handle. 8. Tighten clamping screws alternately and ¼-20 X ¾" bolt to 30 in-lbs. (minimum) of torque. 9. With the valve handle fully open, slide the RBVS housing down until the switch operates plus 1/8 inch. Tighten the screws holding the RBVS to the "offset" bracket. 10. Remove the RBVS switch enclosure cover. 11. Close and open the valve to verify operation. The actuator should easily retract up when the valve handle is in the open position. 12. Fully open the valve. 13. Wire main switch and tamper switch (if applicable). Carefully route tamper switch wires through strain relief channel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1. 14. Replace RBVS switch enclosure cover and securely tighten cover screw. Fig. 3 Typical Electrical Connections Fig. 2 Typical Mounting Diagram Tamper Switch Connections Switch Terminal Connections, Clamping Plate Terminal Table 1 Clamp Sizing Fig. 4 SOME INSTALLATIONS MAY CAUSE INTERFERENCE BETWEEN MOUNTING BOLT AND OFFSET BRACKET. INSTALL BOLT FROM BOTTOM AND TRIM AS NEEDED TO CORRECT. RBVS PIPE DWG# 1086-6 Pipe Valve/Size Clamp Clamping Bolts 1/2" to 3/4" (12,5 to 19mm) Small 10-32 x 2 1/2 1" to 2" (25 to 50mm) Large 1/4-20 x 4" An uninsulated section of single conductor should not be looped around the terminal and serve as two seperate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. HANGERS Model #108 ~B~I 1.-----A --~~ ! I Two-Hole Strap for CPVC Pipe ~-'--.. I APPLICATION: Support horizontal piping from Top, Bottom, or Side of beam. Retainer dimples secure hanger to pipe during installation. Part No. Pipe Size A B Max. Hanger Spacing Finish* 1080075EG 3/4 3-1/8 2-1/8 5-1/2' EG 1080100EG 1 3-5/16 2-1/4 6' EG 1080125EG 1-1/4 4-1/8 3-1/8 6-1/2' EG 1080150EG 1-1/2 4-5/16 3-3/8 7' EG 1080200EG 2 4-7/8 3-15/16 8' EG c®" USTED 1-3/16 '-h B Model #109 1,·,. t LISTED Side Mount Strap for CPVC Pipe ~ ! .~. '. ..... l,l:l: APPLICATION: Support horizontal piping from c®" A~ }ti!J Top or Bottom of beam. Retainer dimples secure hanger to pipe during installation. 1/40 Part No. Pipe Size A B C CL Max. Hanger Spacing Finish* 1090075EG 3/4 2-5/16 1-11/16 2-7/16 1-7/8 5-1/2' EG 1090100EG 1 2-5/8 2 2-11/16 2 6' EG 1090125EG 1-1/4 3 2-3/8 3-1/16 2-1/8 6-1/2' EG 1090150EG 1-1/2 3-1/4 2-5/8 3-5/16 2-1/4 7' EG 1090200EG 2 3-11/16 3-1/16 3-13/16 2-1/2 8' EG Model #50 Stand-Off 2-Hole Strap for CPVC pipe APPLICATION: For mounting CPVC pipe to structural wood or composite wood joists with a minimum 3/8" web thickness. Part No. Pipe Size Finish* S012A 3/4 Pre-Galvanized S016A 1 Pre-Ga Ivanized S020A 1-1/4 Pre-Ga Ivanized S024A 1-1/2 Pre-Galvanized S032A 2 Pre-Galvanized APPLICATIONS FOR MODELS #107, #108, #109, #SO: To support CPVC or Polybutalene fire sprinkler piping in Fire Sprinkler Systems installed per NFPA 13, 13R, and 13D. Fasten with Hardened Hex Head Screw(s), #10 x 1", supplied. Offset edge for abrasion prevention and added strength. NOTES FOR MODEL #107: Install with hanger tabs upward only, If installed inverted, with the hanger tab downward it does not function as a hanger, but as a restrainer. Do not install on the bottom of a beam or under horizontal surface, For these applications, see Model #108, All dimensions are in inches unless otherwise noted. *See page 2 for finish and material descriptions. All material is Carbon Steel unless otherwise noted. Phone: 800-333-0852 • Fax: 800-677-5403 25 www.enco.com Features • Eliminates wood "blocking" materials and labor • No spacer or backup blocks required • Fastest offset CPVC support • Positions CPVC pipe 1-1/2" off the surface • Available for 3/4" -2" CPVC pipe Stand-Off 2-Hole Strap Hanger For CPVC Fire Protection Piping ~L....-_ 3. Fasten the strap to the wood surface using the two screws provided. (#10 x 1 hex washer head 1. Snap strap over CPVC pipe. 2. Squeeze strap back around pipe. (NOTE: Pipe must be allowed to move freely) unslotted, self-tapping.) The SO series hanger for (PVC pipe was tested on a 3/8" thick 05B web, composite wood joist without the use of a traditional wood block and passed the UL 203 test criteria. No Backup Blocks Are Required! COMPLIES WITH STATIC LOAD REQUIREMENTS OF NFPA13 Main Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 909.737.5599 • Fax: 909.737.0330 Customer Service • 800.786.5266 www.tolco.com 40 www.tolco.com Revision 5/24/2001 ™® a brand of Dimensions • Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 25/16 15/32 13/16 51/2 5/16 9 1 25/8 15/16 13/16 6 5/16 9 11/4 3 11/2 13/16 61/2 5/16 11 11/2 31/4 15/8 13/16 7 5/16 12 2 311/16 127/32 13/16 8 5/16 15 Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre-Galvanized Function — Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Order By — Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Fig. 24 -Hanger for CPVC Plastic Pipe Double Fastener Strap Type -Side Mount Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 909.737.5599 • Fax: 909.737.0330 Customer Service • 800.786.5266 www.tolco.com 37 www.tolco.com Revision 3/31/2003 ™® a brand of Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre-Galvanized Function — Intended to perform as a hanger to support only CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. For this type of installation, use the TOLCO™ Fig. 23, Double Fastener Strap for CPVC Piping. Fig. 22, when inverted, with the hanger tab downward, can function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design* protects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw furnished with the product, this is the minimum size fastener acceptable. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been know to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Note — Fastener into light gauge metal may be ordered separately. Minimum acceptable: #10 x 1" Hardened Self Threading Screw with 5/16" hex washer head. Order By — Figure number and CPVC pipe size. * Patent Pending Fig. 22 -Hanger for CPVC Plastic Pipe Single Fastener Strap Type Dimensions • Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 27/16 15/16 13/16 51/2 5/16 9 1 211/16 17/16 13/16 6 5/16 9 11/4 31/16 15/8 13/16 61/2 5/16 11 11/2 35/16 13/4 13/16 7 5/16 12 2 33/4 21/8 13/16 8 5/16 15 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com 70 www.tolco.com Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11⁄4 9500 360 11⁄2 13800 510 Revision 3/26/2008 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 98 -Rod Stiffener Fig. 99 -All Thread rod cut to length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 -All thread rod full lengths Size Range — Secures 3/8" thru 11⁄2" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Dimensions • Weights Component of State of California OSHPD Approved Seismic Restraints System Fig. 200 . "Trimline" Adjustable Band Hanger Size Range -1/2" thru 8" pipe Material -Carbon Steel, Mil. Galvanized to G90 specifications Function -For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2'/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals -Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature -650°F Finish -Mil. Galvanized. For Stainless Steel materials, order TOLCOTM Fig. 200WON. Order By -Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 3'/. 2'/. 400 11 3/4 3/8 8mm or 10mm 3'/. 2'/, 400 11 1 3/8 8mm or 10mm 3'/. 2'/. 400 12 1'/, 3/8 8mm or 10mm 3'/, 2'/. 400 13 1'/2 3/8 8mm or 10mm 3'/. 2'/. 400 14 2 3/8 8mm or 10mm 4'/, 3 400 15 2'/, 3/8 10mm 5'/, 4'/, 600 27 3 3/8 10mm 5'/, 4 600 29 3'/, 3/8 10mm 7'1. 5'/, 600 34 4 3/8 10mm 7'1. 5 1000 35 5 1/2 12mm 9'/. 6'/, 1250 66 6 1/2 12mm 10'/, 6'/, 1250 73 8 1/2 12mm 13'/. 8'/, 1250 136 II Main Office/Manufacturing Facility' 1375 Sampson Ave.• Corona. CA 92879· Ph: 909.737.5599' Fax 909.737.0330 Customer Service' 800786.5/66 www.lolco.com For the most up to date information, visit www.sammysuperscrew.com 4 Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16” OSB) 670 (3/4” Ply) 25 125 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4" Ply) 25 125 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16” OSB) 670 (3/4” Ply) 300 25 125 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 1/4 x 6" 2230 (Fir) 25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) VERTICAL MOUNT WOOD WOOD WOOD WOOD WOOD SAMMYS® for Wood Installs VERTICALLY into the bottom of wood structures easily and quickly! #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite /Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 10. For vertical use -install in in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty 3/8" 8139957 SH-GST 20 1/4 x 2" 1257 (Fir) 1050 1475 25 125 125 3/8" 8141957 SH-GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver Part # 8113910 SAMMY Swivel Head® for Wood Product Features • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Product Features • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. •. Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Installs VERTICALLY and swivels up to 17° in wood structure 5 To find a distributor near you, call 800-BUILDEX Not less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bottom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist HORIZONTAL MOUNT WOOD WOOD WOOD WOOD WOOD SIDEWINDERS® for Wood Installs HORIZONTALLY into the side of wood structures easily and quickly! Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 3/8" 8073925 SWG 20-SS 1/4 x 2" 1725 (Fir) 850 25 125 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 SPECIAL SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS -VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS -HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Composite/Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380 (tools available on pg 10 ) Product Features • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. SAMMYS® FOR WOOD Part No. Model Rod Size Mount Direction UL Max Pipe Size UL Test Load (lbs) UL Min Wood Thickness FM Max Pipe Size FM Test Load (lbs) FM Min Wood Thickness 8007957 GST 10 3/8” Vertical CPVC 1-1/2” 300 1-1/2” 8020957 SWG 10 3/8” Horizontal CPVC 1-1/2” 300 1-1/2” 8008957 GST 20 3/8” Vertical 2-1/2” 850 1-1/2” 4” 1475 1-1/2” 8068925 GST 20-SS 3/8” Vertical 2-1/2” 850 1-1/2” 8010957 GST 30 3/8” Vertical 4” 1500 1-1/2” 4” 1475 1-1/2” 8009925 GST 25-380 3/8” Vertical 4” 1500 1-1/2” 8022925 SWG 25-380 3/8” Horizontal 3-1/2” -4”* 1500 1-1/2” 8021957 SWG 20 3/8” Horizontal 2-1/2” -3”** 1050 1-1/2” 8073925 SWG 20-SS 3/8” Horizontal 2-1/2” 850 1-1/2” 8139957 SH-GST 20 3/8” 17° Angle off Vertical 3” 1050 1-1/2” 4” 1475 1-1/2” 8141957 SH-GST 30 3/8” 17° Angle off Vertical 4” 1500 1-1/2” 4” 1475 1-1/2” For the most up to date information, visit www.sammysuperscrew.com 14 SAMMYS® FOR STEEL Part No. Model Rod Size Mount Direction UL Max Pipe Size UL Test Load (lbs) UL Min. Steel Thickness FM Max Pipe Size FM Test Load (lbs) FM Min. Steel Thickness 8038957 DSTR 1 3/8” Vertical 4” 1500 .035” 4” 1475 .105” 8037957 DSTR 1-1/2 3/8” Vertical 4” 1500 .035” 4” 1475 .105” 8039957 DSTR 516 3/8” Vertical 4” 1500 .037” 4” 1475 .105” 8045957 DST 516 3/8” Vertical 4” 1500 .188” 4” 1475 .188” 8046957 TEK 50 3/8” Vertical 4” 1500 .250” 4” 1475 .188” 8055957 SWDR 1 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” 8056957 SWDR 516 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” 8054957 SWDR 1-1/2 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” 8137957 SH-DSTR 1 3/8” 17° Angle off Vertical 4” 1500 .035” 4” 1475 .105” 8150922 XP 20 3/8” Vertical 2-1/2” 850 .027” 2” 940 .029” 4” 1475 .105” 8153922 XP 35 3/8” Vertical 4” 1500 .060” 2” 940 .029” 4” 1475 .105” 8294922 SXP 20 3/8” Vertical or up to 45° 2” 750 .027” 2” 635 .029” 8295922 SXP 35 3/8” Vertical or up to 89° 3-1/2” 1250 .060” 2” 635 .029” 8293957 SWXP 35 3/8” Horizontal 3-1/2” 1250 .060” SAMMYS® FOR CONCRETE Part No. Model Rod Size Mount Direction UL Max Pipe Size UL Test Load (lbs) UL UL Min PSI FM Max Pipe Size FM Test Load (lbs) FM Min PSI 8059957 CST 20 3/8” Vertical 4” 1475 3000 8061957 SWC 20 3/8” Horizontal 4” 1475 3000 8150922 XP 20 3/8” Vertical 2-1/2” 850 Pre-Pour Structural @3000psi 8150922 XP 20 3/8” Vertical 2-1/2” 850 Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) TRUSS-T HANGER® Part No. Model Rod Size Mount Direction UL Load Rating (lbs) UL Test Load (lbs) Listed Application 8296900 HD38TC 3/8” Top Chord 1200 6075 Maximum 4” Schedule 40 pipe 8297900 HD38BC 3/8” Bottom Chord 1200 6075 Maximum 4” Schedule 40 pipe 8198900 HD12CZP 1/2” Bottom Chord 1200 6075 Maximum 8” Schedule 40 Pipe 8298900 HD12TC 1/2” Top Chord 1200 6075 Maximum 8” Schedule 40 Pipe 8299900 HD12BC 1/2” Bottom Chord 1200 6075 Maximum 8” Schedule 40 Pipe APPROVALS APPROVALS APPROVALS APPROVALS Pipe Hanger Pipe Hanger Pipe Hanger Pipe Hanger PIPE HANGER *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2” *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4” **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2” **SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3” UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 40 www.tolco.com Revision 3/1/2008 Size Range — One size fits 3/4" thru 2" pipe. Material — Pre-Galvanized Steel Function — Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals — Underwriters’ Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish — Pre-Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 Fig. 25 -Surge Restrainer MISCELLANEOUS Open Snoot Assembly FNPT x FNST* Connection Description The single outlet open snoot is constructed of cast brass. The single swivel is complete with gasket and comes standard with pin lugs. Outlet is 2 1/2" NPT female thread. Comes standard with 2 1/2" NST female swivel. Kit includes: open snoot, 2 ½” brass plug with chain, and 2 ½” FDC Brass Wall Plate. Installation Installation can be achieved with tools readily available in the fi eld using common installation practices. Make sure male threads of pipe to which the snoot is being attached are liberally coated with a pipe thread sealant such as PipeFit Thread Sealant with PTFE or PTFE Thread Sealant Tape. Tighten the snoot until hand tight. Tighten one additional turn past hand tight to achieve a water tight seal of the threads. DO NOT OVER TIGHTEN! Over Tightening may cause thread failure as well as cracking of the snoot body. Spe cifi cations Material: Cast brass Size: 2 1/2 FNPT x F Swivel* *Available Swivels: NST 3.0686" x 7.5TPI BCT 3.000" x 8TPI ONT ONT 3.125" x 5TPI QST 3.031" x 7TPI PHX 3.062" x 6TPI TEM 3.075" x 6TPI CLV 3.078" x 8TPI DET 3.125" x 7.5TPI Check thread dimensions for other 2 1/2" applications. ©1999-2007 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com Pressure Gauge Kits Description FPPI ‘s Sprinkler Gauge Kits provide everything needed to install a fi re sprinkler gauge to a riser or other device. Each kit contains a pressure gauge that is UL Listed and FM approved for Fire Sprinkler Service, 1/4” brass 3-way valve, 1/4” x 1/2” galvanized reducer, 1/4” IPS x 4” galvanized pipe nipple and a 1/4” IPS galvanized plug. Each kit is shrink wrapped to a sturdy cardboard backing to prevent the loss of the components before being installed at the job site. Available with Water, Air-Water, Air or Air with Retard fi re gauge. Specifi cations 11-565 Pressure Gauge Kit, Water 11-566 Pressure Gauge Kit, Air-Water 11-567 Pressure Gauge Kit, Air 11-568 Pressure Gauge Kit, Air w/Retard ©1989-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com Spare Sprinkler Head Storage Cabinet Description Installation Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct number of spare sprinkler is as follows: “0-300 sprinklers, not less than 6 300-1000, not less than 12 1000 or more, not less than 24. Stock of spare sprinklers shall include all types and ratings installed.”* Once the correct Spare Sprinkler Head Cabinet has been selected, installation is accomplished by inserting the correct fastener in each of the two holes inside the cabinet, securing the cabinet securely to the wall. The insert the correct number and type of sprinklers in accordance with the “handbook”. *Final determination is subject to approval by the AHJ. Spe cifi cations Material: Painted plain steel Finish: Red enamel Styles: 3 Spare sprinklers, 1/2 or 3/4 6 Spare sprinklers, 1/2 or 3/4 6 Spare, ESFR, 1/2 , 3/4 or 1" 36 Spare sprinklers 24 Spare sprinklers 12 Spare sprinklers 1/2 or 3/4 ©2000-2007 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with "knockouts" to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel fi nish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Escutcheons Fire Sprinkler Accessories 1 800 344-1822 • www.fppi.com 5 2-pc Plastic Pendent Style Manufactured of injection molded plastic. Features 2-3" adjustment for 1/2" IPS spinklers. (The cup may be drilled to .99" for use with 3/4" IPS sprinklers.) Superior corrosion resistance to metal alternatives. Part No. Description Box Qty. 01-850 2-pc Plastic Canopy CP 1/2" 12 01-855 2-pc Plastic Canopy WH 1/2" 12 2-pc Recessed Recessed canopies provide a more finished look to the installed sprinkler than the pendent style escutcheon. Suitable as a lower cost substitution for OEM escutcheons if installed according to individual manufacturer’s specifications. Available in 1/2" or 3/4" IPS and several finishes. Powder coating is used for Black or White finishes. Powder coating provides superior corrosion resistance over painted alternatives. 3/4" adjustment. Part No. Description Box Qty. 01-400 2-pc Rec. Canopy CP 1/2" 200 01-402 2-pc Rec. Canopy WH 1/2" 200 01-406 2-pc Rec. Canopy BR 1/2" 200 01-408 2-pc Rec. Canopy BK 1/2" 200 01-412 2-pc Rec. Canopy CP 3/4" 200 01-414 2-pc Rec. Canopy WH 3/4" 200 01-418 2-pc Rec. Canopy BR 3/4" 200 01-420 2-pc Rec. Canopy BK 3/4" 200 2-pc Recessed, Short Skirt for Residential Sprinklers The Short Skirt recessed escutcheon is similar to the regular recessed canopy. It provides slightly less adjustment for use with residential recessed style sprinklers. Suitable as a low cost substitution for OEM escutcheons if installed according to individual manufacturer’s specifications. Available in 1/2" or 3/4" IPS and several finishes. Powder coating is used for Black or White finishes. Powder coating provides superior corrosion resistance over painted alternatives. 1/2" adjustment. Part No. Description Box Qty. 01-450 2-pc Rec. Canopy CP 1/2" Short 200 01-452 2-pc Rec. Canopy WH 1/2" Short 200 01-456 2-pc Rec. Canopy BR 1/2" Short 200 01-470 2-pc Rec. Canopy CP 3/4" Short 200 01-472 2-pc Rec. Canopy WH 3/4" Short 200