Loading...
HomeMy WebLinkAboutB12-0005NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWWN OVE Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12 -0005 Project #: PRJ12 -0006 Job Address: 181 W MEADOW DR VAIL Location......: VVMC -SUITE 400 - STEADMAN CLINIC 3RD FLO Parcel No....: 210107101013 OWNER VAIL CLINIC INC 01/12/2012 IN CARE OF VAIL VALLEY MEDICAL CENTER PO BOX 40000 VAIL CO 81658 APPLICANT BOULDER ASSOCIATES ARCHITECT 01/12/2012 Phone: 303 - 499 -7795 1426 PEARL ST., STE 300 BOULDER CO 80302 -5340 CONTRACTOR JACKSON BUILDING COMPANY, LL 02/13/2012 Phone: 970 - 331 -6800 PO BOX 6625 VAIL CO 81658 License: 0000003450 Description: INTERIOR REMODEL - AREA (B) MOVE ONE INTERIOR WALL TO INCREASE OFFICE SIZE. AREA (B) ADDING INTERIOR PARTITIONS FOR IT CLOSET. Occupancy: Type Construction: Applied.....: 01/12/2012 Issued...: 02/13/2012 Valuation: $15,000.00 ..............».....<._.......,.,................ .,..,......................,... FEE SUMMARY .. x......................,,.,.................. .........,...,........,..,...w. Building Permit ------ - - - - -> $251.25 Bldg Plan Check ----- - - - - -> $163.31 Use Tax Fee------------------ - - - - -> $100.00 Electrical Permit ---- - - - - -> $0.00 Elec Plan Check ------ - - - - -> $0.00 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $10.00 TOTAL PERMIT FEES -- ----------- > $524.56 Payments -- ---------------------------- > $524.56 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -_4:00 pM. Z nature of Owner or Contractor Date Print Name combination permit_012811 f t TOWN oFMUL CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B12 -0005 Address: 181 W MEADOW DR VAIL Owner: VAIL CLINIC INC Location: VVMC -SUITE 400 - STEADMAN CLINIC 3RD FLO combination permit_012811 I Vfl1 UI 1`t�a REQUIRED INSPECTIONS AND STATUSES Permit #: B12 -0005 Owner: VAIL CLINIC INC 400 - STEADMAN CLINIC 3RD FLO Address: 181 W MEADOW DR VAIL Location: VVMC -SUITE Item: 00120 ELEC -Rough Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00060 BLDG - Sheetrock Nail Item: 00190 ELEC -Final Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R120000070 Amount: $361.25 02/13/201209:47 AM Payment Method:Credit Crd Init: SAB Notation: VISA -BRICE JACKSON ----------------------------------------------------------------------------- Permit No: B12 -0005 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 071 - 0101 -3 Site Address: 181 W MEADOW DR VAIL Location: VVMC -SUITE 400 - STEADMAN CLINIC 3RD FLO Total Fees: $524.56 This Payment: $361.25 Total ALL Pmts: $524.56 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 BUILDING PERMIT FEES 251.25 UT 11000003106000 USE TAX 4% 100.00 WC 00100003112800 WILL CALL INSPECTION FEE 10.00 TOWN OF VA Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -212 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: l �l u t — A. D hnF.At�nu� TI E 7 0 0 (Number) (Street) ``'' `I y,,� (Suite #) Building /Complex Name: V "M Wl 1A"lCAt CA%4 Contractor Information Business Name: - M E E�, P �.4 I 1.4F Business Address: City Contact Name: Contact Phone: Contact E -Mail: State: Zip: Owner /Owner's Representative Signature (Required) Applicant Information Project #: WKED - o 0 DRB #: QQ Building Permit #: &7 - = Lot #: Block # Subdivision: Work Class: New ( ) Addition ( ) Alteration (✓f Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial ( LKOther ( ) Work Type: Interior ( I,,)/Exterior ( ) Both ( Valuation of Work Included Plans Included Work Electrical ( es ( )No ( ✓)Yes ( )No Mechanical ( )Yes ( V)No ( )Yes (<,)No Applicant Name: A A'fE t �S AV- Plumbing ( )Yes ( k4No ( )Yes ( v}No Applicant Phone: 2 nQ AfSOC1 0 - f I - 11 IS Building (vJY ( )No (v)Yes ( )No i;S A A—D Applicant E - Mail: t Rio Po � �acdderaSSo As-9. lem Value of all work being performed: $ IS, Ooo Project Information (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage OJIA Owner Name: _ \ ' Y I �I� C t 4 NIC- ( - Parcel #: alo( - 0"1 1- 01 - 013 (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us /patie) Detailed Scope and Location of Work: 3 Ro FL-"jK-- I of TF4t.m? 1 4- n - 60J - � OF- E>43 - niQ j I �' ArB'- �Et.0 11 ID Oil F_ 1 ?°) "I I_ f_ -� f P[P� Tfor� T t> l CJ-64S E- �Ft G� S 12 f - D i N S l N' V- r- dd 2 (use additional sheet if necessary) For Office Use Only: Fee Paid: Received From: &Q ktN 061- Cash Check # 4 CC: Visa / MC Last 4 CC # exp date: Auth # Date Received: D �J JAN 12 2012 OF VAIL el- Ian -11 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADOCopy Reprinted on 01 -12 -2012 at 13:19:57 01/12/2012 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R120000024 Amount: $163.31 01/12/201201:17 PM Payment Method: Check Init: SAB Notation: 46483 - BOULDER ASSOCIATES ----------------------------------------------------------------------------- Permit No: B12 -0005 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 071 - 0101 -3 Site Address: 181 W MEADOW DR VAIL Location: VVMC -SUITE 400 - STEADMAN CLINIC 3RD FLO Total Fees: $524.56 This Payment: $163.31 Total ALL Pmts: $163.31 Balance: $361.25 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 163.31 THE STEADMAN CLINIC THIRD FLOOR REMODELS OUTLINE SPECIFICATIONS January 09, 2012 DIVISION 00 — INFORMATION: Of C04 Timo le 4 FD ARG� C? THE FOLLOWING DOCUMENTS HAVE BEEN INCLUDED AT THE END OF THIS DOCUMENT. 1) VAIL VALLEY MEDICAL CENTER — CONTRACTOR SAFETY AGREEMENT 2) VAIL VALLEY MEDICAL CENTER POLICY AND PROCEDURE — FIRE AND SMOKE BARRIER SEALING POLICY 3) VAIL VALLEY MEDICAL CENTER POLICY AND PROCEDURE — HOT WORK POLICY 4) VAIL VALLEY MEDICAL CENTER POLICY AND PROCEDURE — INFECTION CONTROL IN CONSTRUCTION / MAINTENANCE 5) VAIL VALLEY MEDICAL CENTER POLICY AND PROCEDURE — LOCKOUT / TAGOUT 6) VAIL VALLEY MEDICAL CENTER POLICY AND PROCEDURE — STAFF AND CONTRACTOR COMPETENCY DIVISION 01 - GENERAL CONDITIONS: 1) GENERAL CONTRACTOR TO SECURE ALL PERMITS, APPROVALS AND INSPECTIONS AS REQUIRED THROUGHOUT PROJECT. 2) GENERAL CONTRACTOR SHALL SECURE AND MAINTAIN AT REQUIRED LIMITS, ALL OWNER AND STATE REQUIRED GENERAL LIABILITY, PROPERTY AND VEHICLE INSURANCE; WORKER'S COMPENSATION INSURANCE; ALL RISK BUILDER'S RISK INSURANCE. OWNER AND ARCHITECT SHALL BE NAMED AS ADDITIONALLY INSURED. SUBMIT COPIES OF CURRENT CERTIFICATES TO THE OWNER AND ARCHITECT. 3) GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT FOR CLARIFICATIONS AND APPROVAL OF PRODUCT SUBSTITUTIONS PRIOR TO PROCEEDING WITH THE WORK SUBMIT TO THE ARCHITECT FOR REVIEW, SHOP DRAWINGS AND PRODUCT DATA FOR ALL MATERIALS REQUIRED FOR THE COMPLETION OF THE PROJECT, PRIOR TO ORDERING MATERIALS. DIVISION 02 — EXISTING CONDITIONS: 1) CONTRACTORS SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND MAKE PROVISIONS WITHIN THEIR BIDS, TAKING IN ACCOUNT LIMITATIONS AND CONDITIONS AS FOUND. D JAN 12012 TOWN OF V AIL Ad-aa5 DIVISION 05 — METALS: 1) STRUCTURAL STEEL: SECTIONS ASTM A36; BENT OR COLD FORMED STEEL PLATE: ASTM A283, GRADE C: STEEL TUBING ASTM A500 GRADE B: ANCHOR BOLTS 3 /< INCH DIAMETER ASTM A325 TYPE 1 HEAVY HEX STEEL BOLTS, ASTM A563 HEAVY HEX STEEL NUTS AND ASTM F436 HARDENED STEEL WASHERS. 2) FABRICATE AND ASSEMBLE IN SHOP TO GREATEST EXTENT POSSIBLE PER REVIEWED SHOP DRAWINGS. CONFORM TO AISC'S "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" SHOP PRIME ALL STEEL WITH ZINC RICH NON -LEAD AND CHROMATE FREE PRIMER. 3) GROUT: NONMETALLIC, NON - SHRINK GROUT: ASTM C1107, FACTORY MIXED. EMBECO 636 OR EQUAL. 4) ERECT STRUCTURAL STEEL ACCURATELY. PLUMB, LEVEL AND STRAIGHT. WELD IN ACCORDANCE WITH AWS D1.1. DIVISION 6 — WOOD, PLASTICS & COMPOSITES: 1) ROUGH CARPENTRY a) FURRING OR BLOCKING: UTILITY GRADE, ANY SPECIES, SIZE AS REQUIRED OR INDICATED. FIRE RETARDANT TREATED AS REQUIRED BY CODE. b) PLYWOOD: EXTERIOR GRADE, SIZE AS REQUIRED. FIRE RETARDANT TREATED AS REQUIRED BY CODE. 2) INTERIOR ARCHITECTURAL WOODWORK: a) INTERIOR STANDING AND RUNNING TRIM AND WINDOWSILLS TO BE AWI CUSTOM GRADE. SEE DRAWINGS FOR SIZE, FINISH AND PROFILE. b) WOOD VENEER AND SOLID WOOD TO BE PLAIN SLICED WHITE MAPLE. 3) SUBMITTALS: a) PRODUCT DATA: FOR CABINET HARDWARE & ACCESSORIES, AND FINISHING MATERIALS AND PROCESSES. b) SHOP DRAWINGS: SHOW LOCATION OF EACH ITEM, DIMENSIONED PLANS AND ELEVATIONS, LARGE -SCALE DETAILS, ATTACHMENT DEVICES, AND OTHER COMPONENTS. c) SAMPLES: i) LUMBER AND PANEL PRODUCTS FOR TRANSPARENT FINISH, FOR EACH SPECIES AND CUT, FINISHED ON ONE SIDE AND ONE EDGE. ii) PLASTIC- LAMINATES, FOR EACH TYPE, COLOR, PATTERN, AND SURFACE FINISH. iii) THERMOSET DECORATIVE PANELS, FOR EACH TYPE, COLOR, PATTERN, AND SURFACE FINISH. iv) SOLID - SURFACING MATERIALS. ION 7 — THERMAL & MOISTURE PROTECTION: 1) BUILDING INSULATION: a) SOUND BATTS: UNFACED GLASS FIBER ACOUSTICAL INSULATION COMPLYING WITH ASTM C 655, TYPE 1. 3 1/2" THICK, WIDTH TO MATCH STUD SPACING. GREENGUARD OR CA 01350 CERTIFIED. OWENS CORNING SOUND ATTENUATION BATT FIBER GLASS OR APPROVED EQUAL. b) SAFING INSULATION: UNFACED 4 PCF MINERAL WOOL COMPLYING WITH ASTM C -612. c) ACOUSTICAL SEMI -RIGID INSULATION: RECTANGULAR BOARDS OF INORGANIC FIBROUS GLASS INSULATION CONFORMING TO ASTM C612 TYPE 1A/1B. INSULATION SHALL BE 24- INCHES WIDE BY 60- INCHES LONG BY 1 1/2- INCHES THICK. INSULATION SHALL BE OF 3.0- PCF DENSITY. INSULATION SHALL BE 703 UNFACED" AS MANUFACTURED BY OWENS- CORNING FIBERGLAS CORPORATION; "INSUL- SHIELD INSULATION, IS 300 " AS MANUFACTURED BY JOHNS MANVILLE; OR APPROVED EQUAL. d) SUBMITTALS: i) PRODUCT DATA: FOR EACH PRODUCT INDICATED. 2) THROUGH - PENETRATION FIRESTOP SYSTEMS: a) ALL FIRESTOP SYSTEMS TO BE TESTED ASSEMBLIES COMPLYING WITH ASTM E814 OR UL 1479. b) PROVIDE FIRESTOP SYSTEMS AT ALL THROUGH - PENETRATIONS OF FIRE RATED PARTITIONS. c) ALL FIRESTOP SYSTEMS TO HAVE AN F- RATING EQUIVALENT TO THE PENETRATED ASSEMBLY. 3) JOINT SEALANTS: a) ALL SEALANTS USED ON -SITE MUST MEET OR EXCEED THE REQUIREMENTS OF THE LIMITS OF THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1168. b) JOINTS BETWEEN EQUIPMENT OR COUNTERS AND WALLS: SILICONE RUBBER BASED, 1 PART ELASTOMERIC WITH MILDEW RESISTANCE FOR WET AREAS. ARCHITECT TO APPROVE COLORS. c) GENERAL PURPOSE INTERIOR SEALANT: LATEX, PAINTABLE (MAX V.O.C. CONTENT 250 GRAMS /LITER) d) ACOUSTICAL SEALANT: PROVIDE AT ALL EDGES OF SOUND RATED PARTITIONS, USG OR EQUAL e) FIRE RATED SEALANT: HILTI CP 606 FIRE STOP OR EQUAL (MAX V.O.C. CONTENT 250 GRAMS /LITER) fl SUBMITTALS: i) PRODUCT DATA: FOR EACH PRODUCT INDICATED. ii) SAMPLES FOR INITIAL SELECTION: FOR EACH TYPE OF FINISH INDICATED. DIVISION 8 - OPENINGS: 1) HOLLOW METAL DOOR & WINDOW FRAMES: a) INTERIOR HOLLOW METAL FRAMES: PROVIDE 16 GA. HOLLOW METAL, FULL PROFILE (WELDED OR KNOCK -DOWN AS INDICATED ON DOOR SCHEDULES); SHOP PRIMED AND FIELD PAINTED FRAMES AS INDICATED ON THE DOOR SCHEDULE. SEE INTERIOR DESIGN MATERIALS LIST FOR COLORS. FIRE RATED WITH LABEL AS SHOWN ON SCHEDULE. b) DOOR FRAMES TO BE STANDARD DOUBLE RABBET PROFILE, WINDOW FRAMES TO HAVE DOUBLE RABBET PROFILE WITH APPLIED STOP TO PROVIDE CENTERED GLAZING. c) SUBMITTALS: i) PRODUCT DATA: FOR EACH TYPE OF DOOR & WINDOW FRAME INDICATED. ii) SHOP DRAWINGS: INCLUDE ELEVATIONS, DOOR EDGE DETAILS, FRAME PROFILES, METAL THICKNESSES, PREPARATIONS FOR HARDWARE, AND OTHER DETAILS. iii) SCHEDULE: PREPARED BY OR UNDER THE SUPERVISION OF SUPPLIER, USING SAME REFERENCE NUMBERS FOR DETAILS AND OPENINGS AS THOSE ON DRAWINGS. 2) WOOD DOORS: a) PREMIUM GRADE, PARTICLEBOARD CORE. b) SOLID CORE FLUSH PREMIUM GRADE DOORS; SPECIES AND GRAIN CUT TO MATCH BUILDING STANDARD, GRADE AA FACES, 5 PLY, WITH FACTORY - FINISHED CATALYZED POLYURETHANE. FINISH TO MATCH EXISTING BUILDING STANDARD. EXPOSED EDGES TO MATCH FACE. SIZE AND FIRE RATING AS INDICATED ON THE DOOR SCHEDULE. MANUFACTURED BY ALGOMA, EGGERS, GRAHAM, MARSHFIELD, OREGON DOOR, OR APPROVED EQUAL. c) PROVIDE WOOD BEADS FOR LITE OPENINGS IN NON - FIRE -RATED DOORS, WOOD- VENEERED BEADS TO MATCH AT FIRE -RATED DOORS. d) SUBMITTALS: i) PRODUCT DATA: FOR EACH TYPE OF DOOR AND WINDOW, GLASS & GLAZING INDICATED. ii) SHOP DRAWINGS: (1) DOORS: INDICATE LOCATION, SIZE, AND HAND OF EACH DOOR; ELEVATION OF EACH KIND OF DOOR, CONSTRUCTION DETAILS NOT COVERED IN PRODUCT DATA; LOCATION AND EXTENT OF HARDWARE BLOCKING, AND OTHER PERTINENT DATA. INDICATE DIMENSIONS AND LOCATIONS OF MORTISES AND HOLES FOR HARDWARE, DIMENSIONS AND LOCATIONS OF CUTOUTS, DOORS TO BE FACTORY FINISHED AND FINISH REQUIREMENTS, AND FIRE - PROTECTION RATINGS FOR FIRE -RATED DOORS. (2) WINDOWS: INCLUDE PLANS ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO OTHER WORK, OPERATIONAL CLEARANCES, AND INSTALLATION DETAILS. 3) DOOR HARDWARE. a) PROVIDE HEAVY DUTY COMMERCIAL GRADE HARDWARE AS INDICATED ON HARDWARE SCHEDULE. FINISH TO MATCH BUILDING STANDARD. b) SUBMITTALS: i) PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. ii) SHOP DRAWINGS: DETAILS OF ELECTRIFIED DOOR HARDWARE, INCLUDING WIRING DIAGRAMS. iii) DOOR HARDWARE SETS: PREPARED BY OR UNDER THE SUPERVISION OF INSTALLER, DETAILING FABRICATION AND ASSEMBLY OF DOOR HARDWARE. (1) FORMAT: USE SAME SCHEDULING SEQUENCE AND FORMAT AND USE SAME DOOR NUMBERS AS IN THE CONTRACT DOCUMENTS. (2) CONTENT: IDENTIFICATION NUMBER, LOCATION, HAND, FIRE RATING, AND MATERIAL OF EACH DOOR AND FRAME. TYPE, STYLE, FUNCTION, SIZE, QUANTITY. AND FINISH OF EACH DOOR HARDWARE ITEM. COMPLETE DESIGNATIONS OF EVERY ITEM REQUIRED FOR EACH DOOR OR OPENING INCLUDING NAME AND MANUFACTURER. DESCRIPTION OF EACH ELECTRIFIED DOOR HARDWARE FUNCTION, INCLUDING LOCATION, SEQUENCE OF OPERATION, AND INTERFACE WITH OTHER BUILDING CONTROL SYSTEMS. iv) KEYING SCHEDULE: PREPARED BY OR UNDER THE SUPERVISION OF INSTALLER, DETAILING OWNER'S FINAL KEYING INSTRUCTIONS FOR LOCKS. COORDINATE KEYING WITH VAIL VALLEY MEDICAL CENTER MASTER KEYING REQUIREMENTS. DIVISION 9 - FINISHES: 1) NON -LOAD BEARING STEEL FRAMING: a) METAL STUDS: TO BE GAUGE AND SIZE AS INDICATED ON PLANS AND SCHEDULE OF PARTITION TYPES. b) HARD CEILINGS & SOFFITS: WHERE APPLICABLE, USG DRYWALL SUSPENSION SYSTEM IN LIEU OF METAL STUD FRAMING. c) SUBMITTALS: i) PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. 2) GYPSUM BOARD: a) GYPSUM WALLBOARD: TO BE 5/8" TYPE "X ", TAPE AND COMPOUND 3 COATS, LEVEL 4 FINISH FOR WALLS SCHEDULED TO RECEIVE WALL COVERING. WALLS AND CEILINGS SCHEDULED TO RECEIVE PAINT SHALL RECEIVE A LEVEL 4 TAPED FINISH. b) PROVIDE GEORGIA - PACIFIC 5/8" TYPE "X" DENSHIELD TILE GUARD AT ALL WET LOCATIONS TO RECEIVE TILE. USE GLASS -MAT WATER RESISTANT BACKING PANEL AT ALL WET AREAS NOT RECEIVING TILE. c) SUBMITTALS: i) PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. 3) ACOUSTIC PANEL CEILINGS: a) ACOUSTICAL PANELS FOR ACOUSTICAL PANEL CEILING: PROVIDE PRODUCT INDICATED ON DRAWINGS. b) INSTALL ACOUSTICAL PANELS WITH UNDAMAGED EDGES AND FIT ACCURATELY INTO SUSPENSION SYSTEM RUNNERS AND EDGE MOLDINGS. SCRIBE AND CUT PANELS AT BORDERS AND PENETRATIONS TO PROVIDE A NEAT, PRECISE FIT. c) SUBMITTALS: i) PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. ii) SAMPLES: FOR EACH EXPOSED FINISH. 4) RESILIENT WALL BASE & ACCESSORIES: a) RUBBER BASE: PROVIDE PRODUCT INDICATED ON DRAWINGS. LENGTH: COILS IN MANUFACTURES STANDARD LENGTH. INSIDE AND OUTSIDE CORNERS TO BE JOB FORMED. b) RESILIENT MOLDING ACCESSORY: CARPET EDGE FOR GLUE -DOWN APPLICATIONS AND REDUCER STRIP FOR RESILIENT FLOOR COVERING. COLOR AND PROFILE AS INDICATED ON DRAWINGS TO MATCH RUBBER BASE. c) FOR RUBBER BASE AND ACCESSORIES USE ADHESIVES THAT HAVE A VOC CONTENT OF 50g /I OR LESS WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24) . d) SUBMITTALS: i) CONCRETE SLAB MOISTURE TEST REPORT (FURNISH PRIOR TO INSTALLATION). ii) PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED INCLUDING ADHESIVES. iii) SHOP DRAWINGS: FOR EACH TYPE OF FLOOR COVERING. INCLUDE SHEET -GOOD FLOOR COVERING LAYOUTS, LOCATIONS OF SEAMS, EDGES, COLUMNS, DOORWAYS, ENCLOSING PARTITIONS, BUILT -IN FURNITURE, CABINETS, AND CUTOUTS. iv) SAMPLES: IN MANUFACTURER'S STANDARD SIZE, SECTIONS OF EACH DIFFERENT COLOR AND PATTERN OF FLOOR COVERING, WELDING RODS, AND RUBBER BASE. 5) SHEET VINYL: PROVIDE PRODUCT SPECIFIED ON DRAWINGS. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SUBSTRATES PREPERATION AND INSTALLATION OF FLOOR COVERINGS. a) ADHESIVES, TYPE RECOMMENDED BY MANUFACTURER TO SUIT PRODUCTS, ROLLING LOADS, AND SUBSTRATE CONDITIONS INDICATED. 6) RESILIENT MOLDING ACCESSORY:CARPET EDGE FOR GLUE -DOWN APPLICATIONS, NOSING FOR CARPET, NOSING FOR RESILIENT FLOOR COVERING, REDUCER STRIP FOR RESILIENT FLOOR COVERING, JOINER FOR TILE AND CARPET. COLOR AND PROFILE AS INDICATED ON DRAWINGS TO MATCH RUBBER BASE. 7) CARPET TILE: a) CARPET TO MEET THE CARPET AND RUG INSTITUTE GREEN LABEL INDOOR AIR QUALITY TEST PROGRAM. b) PROVIDE PRODUCT INDICATED ON INTERIOR MATERIALS LIST. c) ADHESIVES: WATER- RESISTANT, MILDEW- RESISTANT, NONSTAINING TYPE TO SUIT PRODUCTS AND SUBFLOOR CONDITIONS INDICATED, THAT COMPLIES WITH FLAMMABILITY REQUIREMENTS FOR INSTALLED CARPET AND IS RECOMMENDED OR PROVIDED BY CARPET MANUFACTURER. VOC LIMITS FOR ADHESIVES THAT ARE NOT PART OF THE CARPET SYSTEM TO COMPLY WITH THE FOLLOWING LIMITS FOR VOC CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24): INDOOR CARPET ADHESIVE: 50 G /L. d) INSTALLATION: COMPLY WITH CRI 104 AND CARPET MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS FOR THE FOLLOWING: i) DIRECT - GLUE -DOWN INSTALLATION: COMPLY WITH CRI 104, SECTION 14, "CARPET MODULES." ii) COMPLY WITH CARPET MANUFACTURER'S WRITTEN RECOMMENDATIONS AND SHOP DRAWINGS FOR SEAM LOCATIONS AND DIRECTION OF CARPET; MAINTAIN UNIFORMITY OF CARPET DIRECTION PER MANUFACTURER RECOMMENDATIONS. e) SUBMITTALS: i) CONCRETE SLAB MOISTURE TEST REPORT (FURNISH PRIOR TO INSTALLATION). ii) PRODUCT DATA: FOR EACH PRODUCT INDICATED INCLUDING ADHESIVES. iii) SAMPLES: CARPET, EXPOSED EDGE TRANSITION AND OTHER ACCESSORY STRIPPING, CARPET CUSHION. 8) INTERIOR PAINTING: a) ALL PAINTS TO MEET OR EXCEED GREEN SEAL STANDARD GS -11. b) ALL LATEX PAINTS TO BE 100% ACRYLIC. C) LATEX PAINT FINISH HIGH - PERFORMANCE ARCHITECTURAL SCRUBBABLE LATEX (EGG SHELL): 1) MASTER COATINGS TECHNOLOGIES; SCUFF MASTER: SCRUBTOUGH WITH MICOBAN PROTECTION (2 COATS, 4 MILS WFT, 1.6 MILS DFT EACH) NO SUBSTITUTES. II) MASTER COATINGS TECHNOLOGIES, SCUFFMASTER, PRIMEMASTER PRIMER /SEALER (1 COAT,3.5 MILS WFT, 1.0 MILS DFT) NO SUBSTITUTES d) GYPSUM BOARD WALLS: 1 COAT LATEX PRIMER (MAX V.O.C. CONTENT 50 GRAMS /LITER), 2 FINISH COATS EGGSHELL ENAMEL (MAX V.O.C. CONTENT 50 GRAMS /LITER). MAX V.O.C. CONTENT 150 GRAMS /LITER FOR DEEP TONES ONLY. 1) PRIMER: SHERWIN WILLIAMS PRO- GREEN Tm 200 PRIMER OR APPROVED EQUAL II) FINISH COATS: SHERWIN WILLIAMS PRO -GREEN TM 200 EG -SHEL OR APPROVED EQUAL e) DOOR FRAMES: 1 FINISH COAT WATER BASED SEMI -GLOSS ACRYLIC ENAMEL. fl SUBMITTALS: i) PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED, ADHESIVES, AND MANUFACTURERS' PRODUCT DATA FOR PAINTS, INCLUDING PRINTED STATEMENT OF VOC CONTENT AND CHEMICAL COMPONENTS. ii) SAMPLES: FOR EACH FINISH AND FOR EACH COLOR REQUIRED. 9) WOOD STAINS & TRANSPARENT FINISHES: a) TRANSPARENT WOOD FINISH: STAINED VARNISH RUBBED FINISH; 3 COATS OVER STAIN PLUS FILLER ON OPEN -GRAIN WOOD. WIPE FILLER BEFORE APPLYING FIRST VARNISH COAT. (1) STAIN COAT: S -W OIL STAIN A -48 SERIES (2) FILLER COAT: PASTE WOOD FILLER (3) FIRST COAT: S -W OIL BASE VARNISH (4) SECOND COAT: S -W POLYURETHANE VARNISH (5) THIRD COAT: S -W POLYURETHANE VARNISH b) SUBMITTALS: i) PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED AND MANUFACTURERS' PRODUCT DATA FOR STAINS AND FINISHES. INCLUDING PRINTED STATEMENT OF VOC CONTENT AND CHEMICAL COMPONENTS. ii) SAMPLES: FOR EACH FINISH AND FOR EACH COLOR REQUIRED. DIVISION 11 -EQUIPMENT: 1) OWNER FURNISHED EQUIPMENT: a) SEE PLANS FOR LOCATIONS AND EQUIPMENT SCHEDULE FOR DETAILS. CONTRACTOR TO INSTALL OWNER FURNISHED EQUIPMENT ONLY AS NOTED IN SCHEDULE. DIVISION 12 - FURNISHINGS: 1) HORIZONTAL ALUMINUM LOUVER BLINDS: a) PROVIDE AND INSTALL HORIZONTAL ALUMINUM MINI - BLINDS, SLAT WIDTH SHALL MATCH WIDTH OF BUILDING STANDARD, WITH CROWNED PROFILE AND RADIUS CORNERS. BOTH SIDES OF SLATS SHALL BE SAME PREFINISHED COLOR AS SELECTED BY THE ARCHITECT FROM MANUFACTURES FULL RANGE OF COLORS AND SHEEN. SLATS SHALL BE MAXIMUM LIGHT - BLOCKING DESIGN. b) HEAD RAIL AND BOTTOM RAIL SHALL BE FORM FROM EXTRUDED ALUMINUM FULLY ENCLOSING OPERATING MECHANISM. c) PROVIDE STANDARD BRAIDED STRING LADDERS, STANDARD TILT ROD OPERATION FOR WORM -GEAR MECHANISM. LIFT OPERATION SHALL BE BY CONTINUOUS BEADED CORD. PROVIDE MANUFACTURERS STANDARD VALENCE FOR WALL MOUNTED INSTALLATION d) APPROVED MANUFACTURERS SHALL BE HUNTER DOUGLAS, LEVELOR OR DRAPER. e) SUBMIT SHOP DRAWINGS AND SAMPLES FOR APPROVAL. 03 -07 -2012 Inspection Request Reporting Page 7 7 am Vail, CO - City Of Requested Inspect Date: Wednesday March 07, 2012 Site Address: 181 W MEADOW DR VAIL VVMC -SUITE 400 - STEADMAN CLINIC 3RD FLO A/P /D Information Activity: B12 -0005 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: VAIL CLINIC INC Contractor: JACKSON BUILDING COMPANY, LLC Phone: 970 - 331 -6800 Description: INTERIOR REMODEL - AREA (B ) MOVE ONE INTERIOR WALL TO INCREASE OFFICE SIZE. AREA (B) ADDING INTERIOR PARTITIONS FOR IT CLOSET. Requested Inspectionls Item: 50 BLDG - Insulation Requested Time: 08:30 AM Requestor: Phone: Comments: 331 -6800 Assigned To: J R ON Entered By: MHAEBERLE K Action: Time Exp: Item: 90 BLDG -Final Requested Time: 09:00 AM Requestor: Phone: Comments: 331 -6800 Assigned To: JM R ON Entered By: MHAEBERLE K Action: Time Exp: Item: 190 ELEC -Final Requested Time: 10:00 AM Requestor: Phone: Comments: 331 -680 Assigned To: JM N Entered By: MHAEBERLE K Action: Time Exp: Inspection Histo Item: 120 ELEC -Rough ** Approved ** 02/28/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 30 BLDG - Framing ** Approved ** 02/28/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 50 BLDG - Insulation Item: 60 BLDG - Sheetrock Nail ** Approved ** 03/01/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC -Final Item: 90 BLDG -Final REPT131 Run Id: 14183