Loading...
HomeMy WebLinkAboutDRB080033Design Review Board ACTION FORM TOWN Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2139 fax: 970.479.2452 web: www.vailgov.com Project Name: SMITH RESIDENCE DRB Number: DRB080033 Project Description: FINAL APPROVAL OF A NEW SINGLE FAMILY RESIDENCE Participants: OWNER PAUL G. SMITH REVOCABLE TRUS 02/11/2008 8101 E PRENTICE AVE STE 400 GREENWOOD VILLAGE CO 80111 APPLICANT ANNE GUNION /MELISSA BAUM 02/11/2008 Phone: 970 - 949 -7034 PO BOX 1734 VAIL CO 81658 -1734 Project Address: 333 BEAVER DAM RD VAIL Location: 333 BEAVER DAM RD Legal Description: Lot: 41 Block: 7 Subdivision: VAIL VILLAGE FILING 1 Parcel Number: 2101 - 071 - 1200 -6 Comments: BOARD /STAFF ACTION Motion By: DANTAS Action: APPROVED Second By: GILLETTE Vote: 4 -0 -0 Date of Approval: 04/16/2008 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and /or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12 -3 -3: APPEALS. Cond: 202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Cond: CON0009786 Monitored fire alarm system required and shall comply with NFPA 72 (2002 ed.) and VFES Standards. Cond: CON0009787 Fire sprinkler system required and shall comply with NFPA 13R (2002 ed.) and VFES Standards. Cond: CON0009894 Prior to the issuance of a Temporary Certificate of Occupancy, the applicant shall grant and execute all necessary documents for a 10 foot easement along the western boundary of the subject property. Planner: Bill Gibson DRB Fee Paid: $650.00 ` New Construction Application for Design Review Department of Community Development �OOFIV�AL' 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2128 fax: 970.479.2452 web: www.vailgov.com General Information: All projects requiring design review must receive approval prior to submitting a building permit application. Please refer to the submittal requirements for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is received by the Community Development Department. The project may also need to be reviewed by the Town Council and /or the Planning and Environmental Commission. Design review approval lapses unless a building permit is issued and construction commences within one year of the approval. Description of the Request: Pe W S t K--, Location of the Proposal: Lot:!41 Block: 7 Subdivision: Physical Address: ^ UUM 'DA ' m Parcel No.: (Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.) Mailing Address- I -TZ.Z Phone: Owner(s) Signature(s): Name of Applicant: Fax: cowl ❑ Conceptual Review No Fee X New Construction $650 For construction of a new building or demo /rebuild. ❑ Addition $300 For an addition where square footage is added to any residential or commercial building (includes 250 additions & interior conversions). ❑ Minor Alteration $250 For minor changes to buildings and site improvements, such as, (multi - family /commercial) re- roofing, painting, window additions, landscaping, fences and retaining walls, etc. ❑ Minor Alteration $20 For minor changes to buildings and site improvements, such as, (single - family /duplex) re- roofing, painting, window additions, landscaping, fences and retaining walls, etc. ❑ Changes to Approved Plans $20 For revisions to plans already approved by Planning Staff or the Design Review Board. ❑ Separation Request No Fee For Office U,se Oily: Fee Paid: /� j " Check No.: C 1v By: Meeting Date: ✓ `� v _ DRB No.: Planner: v Project No.: .r a o� Type of Review and Fee: ❑ Signs $50 Plus $1.00 per square foot of total sign area. i NEW CONSTRUCTION SUBMITTAL REQUIREMENTS General Information: I The review process for new construction normally requires two separate meetings of the Design Review Board: a conceptual review and a final review. Applicants should plan on presenting their development proposal at a minimum of two meetings before obtaining final approval. I. SUBMITTAL REQUIREMENTS" ❑ All pages of Application is complete ❑ Checklist is completed and signed ❑ Stamped Topographic Survey* ❑ Site and Grading Plan* ❑ Landscape Plan* ❑ Architectural Elevations* ❑ Exterior color and material samples and specifications. ❑ Architectural Floor Plans* ❑ Lighting Plan* and Cut - sheet(s) for proposed fixtures ❑ Title report, including Schedules A & B to verify ownership and easements* ❑ Photos of the existing site and adjacent structures, where applicable. ❑ Written approval from a condominium association, landlord, and joint owner, if applicable ❑ Site - specific Geological Hazard Report, if applicable* ❑ The Administrator and /or DRB may require the submission of additional plans, drawings, specifications, samples and other materials (including a model) if deemed necessary to determine whether a project will comply with Design Guidelines or if the intent of the proposal is not clearly indicated. P /e «se sr16mi!! /ree /3/ c,9pies oft /e mntena /s ai., asmnsk / * *For interior conversions with no exterior changes the submittal requirements include a complete set of existing and proposed floor plans, a title report, and written approval from a condominium association, landlord, and joint owner, if applicable. I have read and understand the above listed submittal requirements: Project Name: Sm MA & : %M "e's Contractor Signature Date Sign F: \cdev \FORMS \Permits \Planning \Old forms \drb_new _ construction_8- 28- 2007.doc Page 3 of 14 UTILITY APPROVAL & VERIFICATION ' 1DiF,M1'�'Jt4'l ' This form serves to verify that the proposed improvements will not impact any existing or proposed utility services, and also to verify service availability and location for new construction and should be used in conjunction with preparing your utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted to the following utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COMMENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact The Town of Vail. Developer to Provide LotAddress Information; Lot Address: Subdivision: Lot #: Authorized Signature Comments Date QWEST 970.468.6860(tel) 970.468.0672(fax) Contacts: Sam Tooley samuel.tooley@gwest.com XCEL HIGH PRESSURE GAS 970.262.4076 (tel) 970.468.1401 (fax) Contact: Rich Sisneros richard.sisneros@xcelenergy.com HOLY CROSS ENERGY 970.947.5471 (tel) 970.945.4081 (fax) Contact: Diana Golis dgolis @holycross.com XCEL ENERGY 970.262.4038 (fax) 970.262.4024 (tel) Contacts: Kit Bogert Kathryn.Bogert@XCELENERGY.com EAGLE RIVER WATER & SANITATION DISTRICT 970.476.7480 (tel) 970.476.4089 (fax) Contact: Fred Haslee fhaslee@erwsd.org COMCAST CABLE 970.418.8248 (tel) 970.949.9138 (fax) Contact: David Evans david evansacable.comcast.com NOTES: 1. If the utility approval & verification form has signatures from each of the utility companies, and no comments are made directly on the form, or no action is taken within 2 weeks of the Utility's receipt of the form without explaination the Town will presume that there are no problems and the development can proceed. 2. If a utility company has concerns with the proposed construction, the utility representative shall note directly on the utility verification form that there is a problem which needs to be resolved. The issue should then be detailed in an attached letter to the Town of Vail. However, please keep in mind that it is the responsibility of the utility company and the applicant to resolve identified problems. 3. These verifications do not relieve the contractor of the responsibility to obtain a Public Way Permit from the Department of Public Works at the Town of Vail. Utility locations must be obtained before digging in any public right -of -way or easement within the Town of Vail. A building permit is not a Public Way permit and must be obtained separately 4. The Developer is required and agrees to submit any revised drawings to the utilities for re- approval & re- verification if the submitted plans are altered in any way after the authorized signature date (unless otherwise specifically noted within the comment area of this form). Developer's Signature Date F: \cdev \FORMS \Permits \Planning \Old forms \drb_new _ construction_8- 28- 2007.doc Page 9 of 14 PROPOSED LANDSCAPING Botanical Name Common Name Quantity Size PROPOSED TREES AND SHRUBS EXISTING TREES TO BE REMOVED Minimum Requirements for Landscaping: Deciduous Trees — 2" Caliper Coniferous Trees — 6' in height Shrubs — 5 Gal. Type Square Footage GROUND COVER :7 SOD SEED IRRIGATION T `� f� TYPE OF EROSION CONTROL �� � �, '� ��� ` �� � ,,; other landsf ape retaining s)alls, fenc pool, etc.) qs, swimming po F:kcdev\FORMS\Pf forms 28-2007.doc Page 8 of 14 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R080000158 Amount: $650.00 02/11/200802:58 PM Payment Method: Check Init: JS Notation: 9986/Vag ARCHITECTS & PLANNERS ----------------------------------------------------------------------------- Permit No: DRB080033 Type: DRB - New Construction Parcel No: 2101 - 071 - 1200 -6 Site Address: 333 BEAVER DAM RD VAIL Location: 333 BEAVER DAM RD Total Fees: $650.00 This Payment: $650.00 Total ALL Pmts: $650.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- DR 00100003112200 DESIGN REVIEW FEES 650.00 FX I LUMINAIRE° THE HARMONY OF PATINA The most successful gardens are a harmonious blend of organic materials. The FX copper line is the perfect match to wood, masonry, and plant materials since the natural patina process allows each fixture to melt into its backgrounds. Compare FX copper luminaires with any other, and you will find a dramatic difference in quality of materials, precision of frt and consistency of finish. PAT H LIGHTING CLASSIC LINES, TIMELESS CONSTRUCTION For those who appreciate the best, this pathway light is designed for both high performance and style. The strong, linear lines of the DelMare® will complement any landscape by day and bring it to life at night. This patent pending luminaire is the best choice for the client who wants a flawless design that will make a long term contribution to their garden. Using high output long life halogen lamps reduces operating and service costs. All FX copper models are well suited for coastal exposures or areas where irrigation water contains high levels of mineral or caustic salts. The copper will patina naturally over time and can be accelerated with solution spray. For patina formulas visit our website at www.FXL.com /patina. 7.00" 0 0 vi PERIMETER LIGHTING © 2 0 0 7 F X L U M I N A I R E$ 8 0 0- 6 8 8 - 1 2 6 9 w w w. F X L. c o m m DM -10, DM -15, DM -20 The DM comes standard with a 20 watt T3 Xenolux® lamp, CapannaDiNoce® (CDS), and in Copper (CU). STANDARD OPTIONS: I + 2 + 3 + 4 ORDERED TOGETHER ON SAME LINE Your choice of one lamp will come pre - installed. T3 Xenolux® CapannaDiNoce® Copper O RDERING + +� +� = DM- 20 -12R PostMount® = PM NON - STANDARD OPTIONS: MUST BE ORDERED ON SEPARATE LINE! Comes pre - assembled with CapannaDiNoce®. All other mounting options will arrive in separate box. Your choice of one riser option will come pre - assembled. Riser Specs: Copper 0.75" Diameter 811 8" Riser 12R 12" Riser 1811 18" Riser K si Superj -boXO' 2.50" x 1100" PM PostMountc 2.50" x 13.00" Copper is standard. All other choices must be specified. • • CU Copper (will naturally patina) Allow extra time for the following finish options: BZ Bronze Metallic 10 r F 4DM 8000 15 8000 20 8000 T3 Xenolux® CapannaDiNoce® Copper O RDERING + +� +� = DM- 20 -12R PostMount® = PM NON - STANDARD OPTIONS: MUST BE ORDERED ON SEPARATE LINE! Comes pre - assembled with CapannaDiNoce®. All other mounting options will arrive in separate box. Your choice of one riser option will come pre - assembled. Riser Specs: Copper 0.75" Diameter 811 8" Riser 12R 12" Riser 1811 18" Riser K si Superj -boXO' 2.50" x 1100" PM PostMountc 2.50" x 13.00" Copper is standard. All other choices must be specified. • • CU Copper (will naturally patina) Allow extra time for the following finish options: BZ Bronze Metallic r= ..h." DG ' Desert Granite BF Black Wrinkle VF Verde Speckle SB Sedona Brown WF White Wrinkle WI Weathered Iron NP Nickel Plate M @200 7 F X L U M I N A I RE' 800-688- 1 26 9 w w w. F X L. c o m' TEKA I L L U M I N A T I O N 3 F C Description Exterior / interior wall mounted luminaire O Q 0 O O O Materials and Construction A. Heavy pure copper faceplate B. Copper rivets C. Translucent etched white acrylic diffuser D. Cast aluminum wall plate with powder coat finish E. Supplied with HPF, electronic ballast for minus 15 °F starting, 120V is standard F. Provided with stainless steel fasteners Mounting Over a recessed 3 1 /2" or 4" octagonal wiring box Product Number Lamp Faceplate Finish Option AFS -5410 13W 2GX7 Copper Brown Patina Options available at extra cost 1. Add suffix BP for brown patina 2. Add suffix # 277 for integral 277V electronic ballast Note Complies with ADA requirements. U.L- and CUL listed, suitable for wet locations T -77 Arcade Full Shield 5 D TEKA ILLUMINATION, INC 86 Gibson Road, #3 Templeton, California 93465 (805) 434-3511 Fax (805) 434 -3512 www.teka- illumination.com © Copyright TEKA2004 FX I LUMINAIRE® DM- 10, DM- 15, DM -20 CLASSIC LINES, TIMELESS CONSTRUCTION For those who appreciate the best, this pathway light is designed for both high performance and style. The strong, linear lines of the DelMare® will complement any landscape by day and bring it to life at night. This patent pending luminaire is the best choice for the client who wants a flawless design that will make a long term contribution to their garden. Using high output long life halogen lamps reduces operating and service costs. PATH LIGHTING THE HARMONY OF PATINA The most successful gardens are a harmonious blend of organic materials. The FX copper line is the perfect match to wood, masonry, and plant materials since the natural patina process allows each fixture to melt into its backgrounds. Compare FX copper luminaires with any other, and you will find a dramatic difference in quality of materials, precision of fit and consistency of finish. All FX copper models are well suited for coastal exposures or areas where irrigation water contains high levels of mineral or caustic salts. The copper will patina naturally over time and can be accelerated with solution spray. For patina formulas visit our website at www.FXL.com /patina. 7.00" 0 0 PERIMETER LIGHTING hh%l, © 2 0 0 7 F X L U M I N A I RE® 800 -688- 1 269 www.FXL.corn ' M The DM comes standard with a 20 watt T3 Xenolue lamp, CapannaDiNoce® (CDS), and in Copper (CU). STANDARD OPTIONS: I + 2 + 3 + 4 ORDERED TOGETHER ON SAME LINE Your choice of one lamp will come pre - installed. DM P K 7'T 10 8000 Is 8000 20 8000 Your choice of one riser option will come pre - assembled. Riser Specs: Copper 0.75" Diameter 0 00* T3 Xenolux® CapannaDiNoce® Copper SECTIONS: DESCRIPTION: WHAT TO ORDER: I , 2 3 4 A NON - STANDARD OPTIONS: MUST BE ORDERED ON SEPARATE LINE! Comes pre - assembled with CapannaDiNoce®. All other mounting options will arrive in separate box. S) Superj -boX® 2.50" x 12.00" PM PoscMount® 2.50" x 13.00" 811 8" Riser 12R 12" Riser 1811 18" Riser Copper is standard. All other choices must be specified. CU Copper (will naturally patina) NON-STOCKING FINISH OPTIONS: Allow extra time for the following finish options: BZ Bronze Metallic DG Desert Granite BF Black Wrinkle VF Verde Speckle SB Sedona Brown WF White Wrinkle WI Weathered Iron NP Nickel Plate m © 2 0 0 7 F X L U M I N A I R E" 8 0 0- 6 8 8 - 1 2 6 9 w w w. F X L. c o m DESCRIPTION The 902 Bollard features a frosted glass diffuser with two distinct shade options offered in two sizes. The various shade options provide a soft . glow" with compact fluorescent, and is also available with incandescent or metal halide lamp technology. SPECIFICATION FEATURES -I Shaper shaperlighting.com Material Post and Fixture: 3 5/8" Diameter seamless pure copper tube attached to a sand cast natural bronze alloy base. The sand cast collar and support arms are natural bronze with a frosted glass diffuser. Optional perforated copper brightness baffle. Curved Shade Options: Spun natural bronze large curved shade (LCS) 5" H x 12" dia., or spun natural bronze curved shade (CS) 2 3/4" x 10" dia. Hipped Hood Shade Options: Formed natural bronze large hipped hood shade (LHHS) 4 1/4" H x 12" Sq. or formed natural bronze hipped hood shade (HHS) 3 1/2" H x 10" Sq. Aluminum components are used with a painted finish. Finish Natural bronze or two component polyurethane paint, 2.5 mil nominal thickness for superior protection against fade or wear. Post & Collar Standard: Natural Bronze (NBZ) or Natural Copper Alloy (CA) [Sustainable Design]. Post & Collar Premium: Plated Satin Zinc (SZ), Black (BK), Grey (GY), White (WH), Dark Platinum (DP), Graphite Metallic (GRM), Silver Metallic (SM), Gold Metallic (GM), Bronze Metallic (BM) or Custom Color (CC). Note: Natural Copper Alloy and bronze will weather to a dark bronze patina. Shades Standard: Natural Bronze (NBZ) [Sustainable DesignJ. Shades Premium: Plated Satin Zinc (SZ), Black (BK), Grey (GY), White (WH), Dark Platinum (DP), Graphite Metallic (GRM), Silver Metallic (SM), Gold Metallic (GM), Bronze Metallic (BM), Verdigris (VG) or Custom Color (CC). Reflector /Optics Spun white painted aluminum. Refer to www.shaperlighting.com for complete photometrics. Ballast One (1) low temperature (0 °F, -18 °C) AC electronic CFL multi -volt 120/277V (347V- Canada) ballast. One (1) metal halide electronic 120V/277V ballast. CFL and MH electronic ballast mounted in post. Installation /Electrical Post is mounted on a cast base collar with three 3/8" x 6" J- bolts. The post is a wire way. The electrical connection is below the removable head and conduit enters at the center of the base plate. Supplied with anchor bolts, mounting hardware and template. Lamp /Socket One (1) 26W (GX24q -3 base), 32W (GX24q -3 base) or 42W (GX24q -4 base) 4 -pin triple tube CFL lamp, one (1) 50W ED -17 medium base metal halide lamp or one (1) 100W A -19 incandescent lamp. CFL socket injection molded plastic. MH and INC socket fired ceramic rated for 4KV. Lamps furnished by others. Options Brightness Baffle (BBL). Labels U.L. and C.U.L. listed for wet location. Modifications Contact the factory regarding scale options, unique finishes, mounting, additional materials /colors, or decorative detailing. Weathered NBZ & CA Patina Factory Bright CA & NBZ 902 SERIES Exterior Bollard Multi -Shade Luminaire ORDERING INFORMATION Sample Number: 902- LHHS -CFV 1- 277V- SM-BK-36 Series Style Lamp Voltage Post Finish Finish' Mounting get= Multi -Shade Luminaire CS= Curved Shade CFL/1 (26/32/42W- Triple) 120V standard standard Height HHS= Hipped Hood Shade INC /11100 277V+ NBZ: Natural Bronze NBZ= Natural Bronze 36" LCS= Large Curved Shade MH /1/50 347Vr Premium Premium LHHS= Large Hipped Hood Shade BK: Black BK' Black Options BM= Bronze Metallic BM= Bronze Metallic BBL= Brightness Baffle Notes: 1 CFL and MH only. CC= Custom Color CC= Custom Color 2 Available with CFL only. 3 Natural bronze or two component polyurethane paint, 2.5 mil DP= Dark Platinum DP= Dark Platinum nominal thickness for superior protection against fade or wear. GM= Gold Metallic GM °Gold Metallic GRM: Graphite Metallic GRM: Graphite Metallic GY =Grey GY: Grey SM: Silver Metallic SM: Silver Metallic WW White VG= Verdigris WH: While COOPER Lighting Specifications and Dimensions subiect to change without notice. ADSO42793 www.cooperl ig hting.com Consult your representative for additional options and finishes. 10/31/2006 4:02:09 PM DIMENSIONS 36" CURVED SHADE (CS) 10"o �2 -3/4" CURVED SHADE (CS) WITH BRIGHTNESS BAFFLE (BBL) 10"o 5-1/2" 3 -5/8" o 3" 36" 902 SERIES EXTERIOR BOLLARD 12" a 10" 12" 6 -1/8" 3 1/2" 5-3/4" 4 -1/4" 36" 36" 73-5/8" a 3 -5/8" a } 3 ° LARGE CURVED HIPPED HOOD LARGE HIPPED HOOD SHADE (LCS) SHADE (HHS) SHADE (LHHS) MOUNTING DETAILS 3/4" 1/2" 3 -5 /8" 0 e2.562 COMPANION PRODUCTS T ikk I 902 -PT -CS 902 -PT -SSG 902 -PT -TS 902 -PT -LCS 694 -WP -RB 13 l� I 694 -WP 691 -WP 692 -WP 693 - WP COOPER Lighting Specifications and Dimensions subject to change without notice. w .cooperlighting.com Shaper Lighting • 1141 Marina Way South • Richmond, CA 94804 • ph 510.234.2370 • fax 510.234.2371 ADSO42793 10/31/2006 4:02:09 PM HOW TO SPECIFY SPECIINING INFORMATION: A- V -R -M -C SERIES K -E SPECIFICATIO STD I It SI Watts per fora _ 2.4 4.8 1.6 Footcandles, six Inches from l ite fixture S 10 Lamp spacing 2" o.c. V o.c. 3" o.c. 6 Limps per/ft 12 lamps per/ft. 4 lamps per/ft. Maximum single Ute fixture 20 linear feet 20 linear feet 20 linear feet B or S SERIES SPECIFICATI % 11) ER W atts per foot i.4 10.8 tamp spacing — 2" o.c. o.c. Maximum single l.ite fixture 20 linear feet 20 linear feet T SERIES Clear Tube Retainer SAMPLE SPECIFICATION: I fighting System tor_ Li—awn) be iTsve A.B V. etc.l Series with 052 T t)Jt brightness, as manufactured by.. . F 112 o SUITABLE FOR WET LOCATIONS T SERIES 16500/ROB Buyline 4899 9413 Mantle Avenue • OkLdmma City, OK 73 Lit 405-728-1895. 14500-65443268 FAX: 405- 72x-1878 LITE FIXTURES Roberts Step -Late Systems' Lite fixtures are available in two light intensities, STD (Standard) and EB (Extra Bright). For specifying, use the photometrics on next page to determine which Live fixture will best suit your clients' needs. LAMPS All lamps are designed exclusively for Roberts Step -Lite Systems, Inc. to our specifications. For the Series A, V, R, C, M, K and E, each 5 volt, .ISmscp .115 amp lamp is selected to within + -195, of the rated current to ensure conformance through all of our lighting fixtures. The approximate lamp life is 100,000 hours. For Series B and S, 1.8 watt, 75Mamp, 24 volt extra bright lamps are rated at 10,000+ hours, while the .9 watt, 371yfamp, 24 volt standard brightness lamp is rated at 15,000+ hours. lamps are warm to the touch and can be re- tamped while the fixture is on. Each lamp is mounted to a base plug for socket insertion for quick installation. All B and S -Series fixtures come pre - tamped, ready to install. TUBING All of the rigid tubing used by Roberts Step -Lite Systems, Inc. is 1132" thick, clear poly -carbonate "Lexan® 103" or equivalent, Ul, inflammability rating 94 V -2 on the resin, UV stabilized. Our Superflex tubing is clear polyvinyl, UL rating 94 V -1. Each Step -Lite is sealed to make it the natural choice for "wet location" requirements. r i I t C SERIES M SERIES -- B SERIES 1 KSERIES ASERIES � SSERIES E SERIES V SERIES R SERIES 0 16500/ROB Buyline 4899 \� roBrts sfiep -lice systems Roberts' low- voltage lighting systems have become so popular with On step applications, a nosing overhang of one inch is required. In architects, designers and contractors that nine totally different curved applications, small cuts through all but the inside wall of the systems are now available. Each one is specifically designed to help you enhance the beauty of your project and add the extra safety lighting provided by these concealed lighting systems. The smallest of Roberts' nine different Step -Lite systems is the extrusion material may be required to ease curving of the extrusion. This process is called "kerfing." Roberts supplies a clear rubber silicone sealant to be used to apply the extrusion to clean and level surfaces. This silicone will stretch to A- Series. This is also the easiest system to conceal and the most three times its original size and will adhere in sub -zero or extremely flexible to use. The A- Series Step -Lite is perfect for handrail applications due to its small size. For surface mounted or recessed applications, the A -Series is 1/2" wide by 7/16" deep, and may be used indoors or outdoors with either STD or EB Lite fixtures and with Superflex tubing. high temperatures. Except for long lengths, Roberts Lite fixtures are shipped mounted into the extrusion, ready for installation. Dptic Products, Inc. - Pavers Item Paver Light Blocks ..l uv� Lf Image: DescrIM1011. "Paver Light Blocks 3 -7 /8 x 3- 7/8' x 2- 3/8 " "' ABS plastic, frosted top are designed to be set in walkways with brick or cement, you can use them in walls also. Use our EG12, EG15 or EG25 cable for lighting blocks. Recommend 100 watts min light unit-Special order Only now, please call 707 -998- 3903" Stock# Paver Category: Pavers Items 1 - 1 of 1 1111IR 1� ! ' + i ! f 'ova� WN Survey /Site Plan Review Checklist Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2128 fax: 970.479.2452 web: www.vailgov.com *This check list must be submitted prior to Public Works review of proposed development. Owners /Project Name: S M& I? SASIvzM4Z Project Address: 3'33 ) Fk%WJL I)O►Nl tZCA&0 Applicant: $Let 14 9%J 156h 1 "14 Phone Number: oI�3'7 Submittal ❑ Stamped survey of property ❑ Civil /Site plans ❑ Landscape plan ❑ Title Report (Section B) Survey Requirements: ❑ Surveyor's wet stamp and signature ❑ Date of survey ❑ North arrow ❑ Proper scale (1 " =10' or 1 " =20') ❑ Legal description ❑ Basis of bearings / Benchmark ❑ Spot Elevations ❑ Labeled right of way and property lines; including bearings, distances and curve information. ❑ Lot Size ❑ Build able Area (excludes red hazard avalanche, slopes greater than 40 %, and floodplain) ❑ Environmental Hazards (ie. rockfall, debris flow, avalanche, wetlands, floodplain, soils) ❑ Watercourse setbacks (if applicable) ❑ Trees ❑ Labeled easements (i.e. drainage, utility, pedestrian, etc...) ❑ Topography ❑ Utility locations ❑ Adjacent roadways labeled and edge of asphalt for both sides of the roadway shown for a minimum of 250' in either direction from property. Site Plan Requirements: I. Access (check all) ❑ Driveway type and finished surface are shown on the site plan. ❑ Unheated ❑ Heated (portion in ROW in a separate zone) ❑ Snow storage areas are shown on the site plan within property boundaries (30% of driveway area if unheated; 10% of driveway area if heated) ❑ All driveway grades, dimensions, radii are clearly noted on the site plan and conform to Development Standards, p. 11. Steepest Section Driveway Grade (not the average grade): ❑ Parking spaces and turning radii are noted on site plan and conform to Development Standards, pp. 12&14 II. Construction Site (check all) ❑ Location of all utilities and meter pits are shown on the site plan. ❑ Limits of disturbance construction fencing is shown on the site plan. ❑ I am aware that approved Staging and Construction Traffic Control Plans, as per the Manual of Uniform Traffic Control Devices, will be necessary prior to construction. Li � I am aware that a Revocable Right of Way Permit will be required prior to construction. A F: \cdev \FORMS \Permits \Planning \Old forms \drb_new _ construction_8- 28- 2007.doc Page 12 of 14 New Construction Application for Design Review O Department of Community Development TOWN 75 South Frontage Road, Vall, Colorado 8!657 tel: 970.479 .2128 fax: 970.479.2452 web: www.vaiigov.com General Information. All projects requiring design review trust receive approval prior to submitting a building permit application. Please refer to the submittal requtnements for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is received by the Community Development Department. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval: lapses unless a building permit is issued and construction commences within one year of the approval. /3 Description of the Request: Location of the Proposal: Lot:. 4 d - _Block: _. Subdivision:_UI4A fu.ahA Physical Address: _," .- 59�k4g#— DWA Z D .._. Parcel Na,: ,Z1,Q�"�200 (Contact Eagle Co. Assessor at 970 328.8640 for parcel no.) zoning: _ruj*., "8 iL )7 Fmi m_ SBC�C�lD �� i>a5i p A Name(s) of Owner(s): V Ado- 4►_44& M � 11u. _ .__ Mailing Address: Phone:. Z, ,gip Owner(s) Signature(s)`: Name of Applicant: t..._r.._'"... �-'u _. _ Mailing Address: ....�15 _ _"t _� ___ 0 _ .... ._ Phone: E -mail Address: th a Fax: a til-InJ& — Type of Review and Fee: Cl Signs $50 Plus $1.00 per square foot of total sign area. U Conceptual Review No Fee X Uew Construction $650 For construction of a new building or demo /rebuild. ;_:l Addition $300 For an addition where square footage is added to any residential or commercial building (includes 250 additions & interior conversions). C: Minor Alteration $250 For minor changes to buildings and site improvements, such as, (multi family /commercial) re- roofing, painting, window additions, landscaping, fences and retaimog wafts, etc. r! Minor Afteratity) $20 For minor changes to buildings and site improvements, such as. (single - family /duplex) reroofing, painting, window add ition s, andscaping, fpnc ar.d retaininq walls, etc. D Changes to Approved Flans $20 Fix revisions to plans already approved by Planning Staff or the Design Review Board. ❑ Sepatation Request No Fee For Office Use Only: =ec Paid: Check No. By: Meeting Date :. _ DRB Wo.:... ....... ___ - ..... _._._........._. -- i Planner:... . - -- _ -__ —. __,__ _ _ _ _— Project No FILE COPY 10fl Bill Gibson - Smith Residence - Public Work's comments From: Bill Gibson To: Melissa K. Baum Date: 04/04/2008 10:21 AM Subject: Smith Residence - Public Work's comments Hey Melissa, Here are the Public Works Department's comments for the Smith Residence: 1) The Town requests a drainage easement along the west lot line to accommodate future drainage improvements on Beaver Dam Rd. This drainage easement would allow conveyance of storm water from Beaver Dam Rd to Gore Creek. 2) Please indicate the Gore Creek 100 year flood plain on the site plan/ survey. 3) A revocable right of way permit is required for private improvements located within the public right of way (ie: heated driveway, landscaping, etc.) Sincerely, Bill Bill Gibson, AICP Town Planner Town of Vail 75 South Frontage Road Vail, CO 81657 (970) 479 -2173 (970) 479 -2452 fax file: //CADocuments and Settings\Administrator \Local Settings \Temp \XPgrpwise \47F601... 04/04/2008 PLANNING CHECK SHEET Property Information Property Address 333 Beaver Dam Road Parcel # 210707112006 Legal Description Lot 41, Block 7, Vail Village Filing 1 Development Site Area Ac 0.880 Sq Ft 38,333 Buildable n/a Zoning / SDD # Two - Family Primary /Secondary (P /S) Land Use Designation Low Density Residential Known Non - Conformities n/a Previous Approvals n/a Hazard Zones Sections 12-12,12-21, 14 -6 & 14 -7 Snow Avalanche n/a Debris Flow n/a Rockfall n/a Excessive Slopes (Site Disturbance 12- 21 -14) n/a Floodplain n/a Wetlands Y/N n/a Creeks, Streams Section 12 -14 -17 Setback n/a Proposed n/a Sidewalks/ Trails n/a Contact Information Planner/ Date BG 04/14/08 Owner Contact Info Paul & Annette Smith Primary Contact/ Owner Representative Info VAg Architects (Melissa Baum) 949 -7034 Project Information Project Description New single-family Land Use Application(s) # DRB080033 Proposed Uses (As defined by Zonin Single- family dwelling Permitted, Conditional, I Prohibited? Permitted Date Routed/ DRT Meeting 02/12/08 & 04/02/08 Commercial Floor Area Existing n/a Proposed n/a Gross Residential Floor Area (Chapter 15) Total Allowed 8,950 - Existing Demo - Proposed 8,939 +Credits Prima n/a - Existing Demo - Proposed n/a +Credits Secondary n/a - Existing Demo - Proposed n/a +Credits Total Remaining 11 Primary Total Remaining n/a Secondary Total Remainin n/a 250 or Interior Conversion? n/a Zoning District Standards Setbacks (perimeter) Projections 14 -10 -4 Front 20 Proposed or Y/N Y Side 15 & 15 Proposed or Y/N Y Rear 15 Proposed or Y/N Y Minimum Lot Area/ Width Required 14,000 Proposed or Y/N n/a Site Coverage % Allowed 7,667(20%) % Proposed 5,953(16%) Building Height Allowed 33/30 Proposed Y Landscaping Sections 14 -10 -8 & 14 -10 -9 % Required 23,000 (60 %) % Proposed 29,345 (77 %) Plant size 6', 2 ", 5 gal. Proposed Y Fences n/a Proposed n/a Retaining Walls Sec. 14-6-7 Height Allowed 6 Proposed Y Setback 2 Proposed Y Driveway Sections 14 -3 -1 & 14 -3 -2 Max Curb -cuts 24' Proposed Y Max Slope 12% Proposed Y Min Width 12' min Proposed Y Heated Y/N Y Drive Material Pavers Snow Storage % 10% Proposed 10 %+ Parking Sections 12 -10 & 14 -5 Spaces Required 6 Proposed Loading n/a Proposed n/a Lighting Section 14 -10 -7 Allowed 38 fixtures Proposed 10 Waste Management Section 5 -9 Wildlife Proof / Resistant n/a Screened n/a Screening Sections 14 -10 -9 & 14 -10 -10 Required Proposed Y Roof Material Sections 12 -11 -3C & 14 -10 -5 Complies Y/N Y Building Separation Section 14 -10 -6 Complies Y/N Y Adopted View Corridors Complies Y/N n/a Utilities (Location, easements) Section 14 -10 -10 Y Grading (Less than 2:1) Section 14 -6 Y Development Impact Fees / Mitigation Employee Housing n/a Traffic Impact n/a Art In Public Places n/a Notes