Loading...
HomeMy WebLinkAboutB12-0019 comment letter Date: 2/17/2012 Re: B12-0019 765 Forest Road Dear Mr. Riden RESPONSE INSTRUCTIONS ● Submit three complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. ● Please respond in writing to each comment with a response letter addressing each comment. BUILDING COMMENTS Architectural Comments: Sheet A03 1. Please clarify that the proposed gas fireplaces/ appliances are in compliance with section 5-3-4 of the Town code Dwelling Units: Dwelling units shall contain not more than one certified solid fuel burning device or not more than two (2) gas log fireplaces Utilize definitions of this section to reflect the proposed installation. Definit ions: GAS APPLIANCE: A fully self-contained, Underwriter's Laboratories, Inc. (UL) listed and American Gas Association (AGA) "fireplace" unit which does not require venting through a chimney and which does not permit the use of solid fuel. GAS LOG FIREPLACE: A fireplace as defined herein equipped with an AGA and UL listed artificial log unit which is approved for the burning of natural gas. Sheet A21 and A22 1. Revise plans to reflect the opening is less than 4 “ at guards. Reference section R312.3 IRC Structural Comments: General 1. Please specify on plans the required special inspections per section 1704.1.1 IBC Plumbing Comments: Reviewed and accepted Mechanical Comments: Reviewed and accepted Electrical Comments: Sheet E01 1. Revise general notes on all related sheets to reflect a required 50% high efficacy for all new lighting proposed. Reference section 404.1 IECC. PLANNING COMMENTS 1. Provide plan for patio removal on Town property, including revegetation plan 2. Show development standards on plans (GRFA, site coverage, landscape area, etc) FIRE COMMENTS PUBLIC WORKS COMMENTS Sincerely, Martin A. Haeberle Chief Building Official