B12-0029 FIRE ALARM 022412 (MOVE ONCE FA PERMIT RECEIVED)
LEGEND: SYMBOL DEVICE DESCRIPTION 4" 36" FACP N� MINIMUM Fire Alarm Control Panel FINISHED CEILING ? P DIFFUSER 4" MIN TO TOP CEILING MOUNTED MIN 6" ANN LCD Annunciator 12" MAX TO BOTTOM SMOKE DETECTOR i MEASURE FROM TOP OF DEVICE E]< WALL MOUNTED AUDIBLE DEVICE BPS �P Booster Power Supply 96" MAX (TOP OF LENS) WALL MOUNTED WALL MOUNTED VISUAL OR AUDIBLE/ DEVICE Manual Pull Station ~� SMOKE DETECTOR F ,Q, / 80" MIN (BOTTOM OF LENS) O NOT LESS THAN P Photoelectric Smoke Detector 90" ABOVE MEASURE TO TOP OF CABINET FACP FIRE ALARM CONTROL PANEL ® Heat Detector (fixed) ENTIRE LENS SHALL BE WITHIN 80"-96" MEASURE TO TOP OF UNIT RT- LCD LCD ANNUNCIATOR Duct Detector w/Test Switch 72„ TO CENTER OF DEVICE RT DUCT DETECTOR TEST STATION I>M Horn/Strobe, wall mount NORTH BUILDING TO CENTER OF DEVICE ❑ w (EXISTING P MANUAL PULL STATION 0 NOTIFIER 640 Horn/Strobe, ceiling mount TO REMAIN) 64"-68" ® r 1 60" 42"-48" .0' Strobe (candela specified) Horn Only ^� ALL HEIGHTS MEASURED FROM FINISHED FLOOR EAST BUILDING STANDARD MOUNTING HEIGHT DETAIL '"ID Weatherproof Horn/St ~ Q robe � OQ (CURRENTLY REPORTS NOT TO SCALE Q� TO SOUTH BLDG FACP) �T� NEW NOTIFIER FACP WILL BE MOUNTING HEIGHT NOTES: -�-� Sprinkler Waterflow Switch O INSTALLED IN SOUTH BLDG 1. MOUNTING HEIGHTS ARE PER NFPA 72 AND ADA ACCESSIBILITY GUIDELINES. UNDER THIS SCOPE OF WORK 2. REMOTE LIGHTS AND REMOTE TEST STATIONS SHALL BE MOUNTED ON THE WALL BELOW ITS ~� ASSOCIATED DEVICE & SHALL BE CLEARLY VISIBLE. Sprinkler Valve Tamper Switch 3. ADDRESSABLE MODULES SHALL BE MOUNTED AS TO BE ACCESSIBLE. 4. WHERE LOW CEILING HEIGHTS DO NOT ALLOW FOR VISUAL OR AUDIBLE/VISUAL DEVICES TO M O O BE INSTALLED AS NOTED, APPLIANCES SHALL BE MOUNTED WITHIN 6" OF THE CEILING. CR Control Relay w l 5. IN ADA UNITS, 11OCD STROBES MUST BE MOUNTED 24" BELOW THE CEILING. 6. MOUNT EXTERIOR HORN/STROBES 10' ABOVE FIRE DEPARTMENT CONNECTION. MM �1 O Single Monitor Module DH //��--11 � � • ^ Door Holder (120V) O Fire/Smoke Damper o SITE PLAN (function noted, 120V) �..� SOUTH BUILDING O? (EXISTING NOTIFIER SB Addressable Smoke Detector w/Sounder Base AFP 400 TO BE REMOVED AND REPLACED WITH NEW NOTIFIER NFS3030 UNDER THIS SCOPE z w o � V SITE PLAN/SCOPE OF WORK NOTES: Q z U O THE EAST BUILDING CURRENTLY REPORTS, THROUGH CONVENTIONAL ZONES, TO THE SOUTH BUILDING NOTIFIER AFP400 FACP. UNDER Q � oZa THIS SCOPE OF WORK, THE AFP400 IN THE SOUTH BUILDING WILL BE REPLACED WITH A NEW NOTIFIER 3030 FACP. THE EAST AND - - SOUTH BUILDINGS WILL CONTINUE TO BE MONITORED BY ONE FACP, BUT WILL DIAL OUT AS SEPARATE RESPONSE POINT TO THE Z FIRE DEPARTMENT MONITORING STATION. J w � z w SEQUENCE OF BUILDING PERMIT 2-23-12 z Q w z z DD PRICING 10-31 -11 m CD z SD PRICING 8-8-11 OPERATIONS : z z z Cn J w O c o w ISSUED FOR: DATE :CD � O U FIRE ALARM WIRE TYPE CHART J C w O Q m p m I- I- -J cn Q m CD Label Description Suggested Wire Type o z M m C/) > cn m g Iz LLJ AC 120VAC Power Wiring 3#12 AWG Solid (w/Ground) Q < O Q m O Q z 0 0 w � (w m cn L Signaling Line Circuit #18 AWG Twisted Pair g O m Q o- z Q LiJ P 24VDC Power Wiring 2#14 AWG Solid- < Q z Cn O (n O 0 J z Q N Notification Appliance (Horn/Strobe) Wiring 2#14 AWG Solid Lli w w f- z z F-- L: w J o w 0 w 0 X Auxiliary Circuit (Relay) Wiring 2#14 AWG Solid Z � Shaner Life Safety DEVICE Q Q W 0 0 z 0 � O z w Q z w � Z Indicating Device Circuit (Zone) Wiring 2#16 AWG Solid DESCRIPTION > > U Q Q z � � � J w -1 O A Annunciator Wiring 2#18 AWG Solid f > < 0 0 Q = O O z — 0- w O PO Box 1073, Frisco, Colorado 80443 0 0 0 ry 0 (n a_ Cn 0 z O D SHANERLS®COMCAST.NET; (970) 409-9082 1. NO T-TAPPING PERMITTED ON ANY CIRCUIT, UNLESS ALLOWED BY MANUFACTURER, 2. WIRING SHALL BE IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS, MANUAL PULL STATIONS X X X X TO NEXT REMOTE POWER SUPPLY SYSTEM SMOKE DETECTORS X X X X I- Y N U �/ �/ �/ THESE DRAWINGS AND SPECIFICATIONS AND THE ELEV LOBBY/SHAFT/EQUIP RM SMOKE X X X X IDEAS, DESIGNS AND ARRANGEMENTS DOGE W REPRESENTED THEREBY ARE AND SHALL REMAIN HOLDER L7 -' RELEASE U U �EOLR PROPERTY OF THE ARCHITECT, AND NO PART DH � z 0 THEREOF SHALL BE COPIED, DISCLOSED TO Z Z ~ (TYP) (TYP) OTHERS, OR USED IN CONNECTION WITH ANY HEAT DETECTORS (ELEV SHAFT, EQUIP RM) X X X X X L (n 0- WORK OR PROJECT FOR WHICH THEY HAVE BEEN M M CR ? 0 U N PREPARED WITHOUT THE WRITTEN CONSENT OF (TYP) (TYP) (TYP) (TYP) (TYP� 0° 0�EOLR THE ARCHITECT. VISUAL CONTACT WITH THESE (TYP) (TYP) DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN WATERFLOW SWITCH X X X X HOLDER N FACP NAC1 DIMENSIONS ON THESE DRAWINGS SHALL HAVE `- -" RELEASE PRECEDENCE OVER SCALED DIMENSIONS. ELEV - ' REMOTE 0�EOLR CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE EAST BLDG FOR ALL DIMENSIONS AND CONDITIONS ON THE FUNCTIONS Z Z " POWER (TYP) (TYP) JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VALVE TAMPER SWITCH X X L FIRE ALARM RT� Ek CR— M M CR F 1 ? TERMINAL SUPPLY VARIATIONS FROM THE DIMENSIONS AND (TYP) (TYP) (TYP) (TYP) (TYP) (TYP) (TYP) (TYP� L CABINET 0�EOLR CONDITIONS SHOWN BY THESE DRAWINGS. ROOM SMOKE DETECTORS X X (TYP) (TYP) L N FACP NAC2 SYNC CIRCUIT AC POWER LOSS X X CONNECTION TO SOUTH BLDG FACP FIRE ALARM COVER SHEET GROUND FAULT X X SYSTEM A PRINTER I NEW OPEN CIRCUIT/SHORT CIRCUIT X X SYSTEM RISER DIAGRAM LCD REMOTE A NOTIFIER ANNUNCIATOR 3030 FACP (LOCATED IN SOUTH BUILDING AT FRONT DESK) NOTE: ELEVATOR RECALL CONSISTS OF PRIMARY AND SECONDARY RECALL. PRIMARY RECALL IS TO THE GROUND FLOOR, SECONDARY IS TO THE 2ND FLOOR. PRIMARY RECALL OCCURS WHEN THE SMOKE DETECTORS IN THE ELEVATOR EQUIPMENT ROOM, DEDICATED 120V SHAFT, OR ELEVATOR LOBBIES EXCEPT GROUND FLOOR ACTIVATE. SECONDARY RECALL TO FACP Ac FA1 . 0 OCCURS WHEN THE SMOKE DETECTORS LOCATED IN THE GROUND FLOOR ELEVATOR LOBBIES ACTIVATE. I~� W w ———— — ————— — — — — — — — — — — — —— ——— — — — — — — — — — — — —— — — —— ——— — OQ 0 ❑1 HELPHENS WHITE O CHANNEL O O SB O SB 003 S13 � 002 � 2 001 0 � ^ MCINTYRE 1 0� OSB �S� SB O O O O G Ll 1)-H I -7 03 0 004 a � v 0 0 0 r-'\\ FO— FO-01 0 0 0 ❑ a o o o0 0 o O E CORRIDCR OC_ ,� Op 005 C O P I�N��Iv�/JII P 0 P (E) KITCHEN (N) STAIR o15 O C OlOA ® CU 0 ��I O c (E) CORRIDOR Op MM R y U (E) MECH. (E) BREAK n. N D R)�== O Z o M ROOM ROOM ROOM P ❑ m T � ° P n M Q O M SF-1 FC-1 v Q a F ( o o Z a DH Q u - M Nz z El ® ® � ❑ O � wZM ® � z0 w U Z Q ti O ° Op O ° ® O ° O O Op P° ° ED El P ® Op O o ° ® ® ° O O O (E) OFFICE P 014 El 1:1 El EN111 � OP ® ° ® ® ° BUILDING PERMIT 2-23-12 ? O ° DD PRICING 10-31 -11 ® SD PRICING 8-8-11 (E) WILDWOOD ❑ ❑ ISSUED FOR: DATE: ROOM NOTES : FLAG NOTES : 013 ® Op O ° O O ° Op 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. O BASES SHALL BE PROVIDED. SMOKE SENSOR NOTIFIER ACCLIMATE DETECTORS WITH SOUNDER ` El ED 2. A NEW FIRE ALARM SYSTEM SHALL BE PROVIDED SHALL ACTIVATE A SUPERVISORY CONDITION AT THROUGHOUT THE BUILDING. REFER TO SYSTEM THE FACP AND SOUND A LOCAL ALARM Shaner Life Safety SPECIFICATIONS FOR DESIGN REQUIREMENTS. THROUGHOUT THE UNIT (TANDEM WIRE O ® ° O — 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND DETECTORS TOGETHER). THE HEAT SENSOR ® ° ® Po Box 1073, Frisco, Colorado 80443 ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE SHALL ACTIVATE GENERAL ALARM IN THE 0 0 0 SHANERLS®COMCAST.NET; (970) 409-9082 ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE BUILDING. SOUNDER BASES PROVIDE GENERAL a a a C LOCATIONS, SYSTEM DESIGN AND INSTALLATION. ALARM SIGNAL IN UNITS. ED � Q 4. RUN FIRE ALARM WIRE IN NEW SOFFITS BUILT FOR 0 0 THE SPRINKLER UPGRADE. SOFFITS ARE NOTED O FIRE ALARM TERMINAL CABINET. FIRE ALARM ® Op O ° ON THIS SHEET. CONTRACTOR SHALL PULL REQUIRED DATA, ® Op ® ° NOTIFICATION AND SLC CIRCUITS FROM THE NEW SOUTH BUILDING FACP. OOVERHEAD DOOR, TO BE CLOSED ON O O THESE DRAWINGS AND SPECIFICATIONS AND THE BASEMENT ALARM OR WATERFLOW IN BUILDING. IDEAS, DESIGNS AND ARRANGEMENTS PROVIDE CONTROL RELAY FOR INTERFACE TO REPRESENTED THEREBY ARE AND SHALL REMAIN FIRE ALARM SYSTEM. PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE BASEMENT FLOOR PLAN FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND SCALE: 1/89$ = 11-099 CONDITIONS SHOWN BY THESE DRAWINGS. BASEMENT FIRE ALARM PLAN FA2 . 0 O I~� w O w �ll rr O V STAIR E 0 0 M--� w � Qr W O ❑ c STAIR F ❑ ❑ — w 106 110 v 1 ❑ ❑ ❑ � � 00 20 � O ❑ ❑ ❑ — J SIB SB OSB TOMPKINS HUZELLA �/1 ►� 103 w 101 O MCINTYRE D 105 O q LJ o 0 m 0 0 D1Q0 0 L7 0 O O2 O O2 O 2 O 4SB ? SB O SB SB SB 00 O SB r-L 0 0 0 0 0 O z z a C-HAN MITNICK OLTHOF BERMUDE, - C ° 113 111 109 107 O 0 0 C C w w ~ ° M O p STAI R H Q OO Q w 114 ORRIDg o Y C N J a O O O Q SB OSB 7�SB OSB 0 0 0 2 0 2 u w w Z SB SB SB SB Q o o o o Q 0 a Q o 0 2 O 7 O w u Z J 0 4' 0 0 0 O O CORRIDOR Q SB SB �� �� 00 0 c� 00 ,00 OP 0 0 OP Q ❑D 0 0 0 0 2 STAIR ELEV. SB O SB ,04A 20 20 O 20 O 10 0 CHAN YEE OsB 0sB OsB �sB O2 O2 1 117 115 ORRIDO OSB OSB ORRIDO SB SB - OP 112 108 0 STAIR C 0 -)'TAIR B j 0 C OP 112A 108A CR(4) Ad LA�6SB 0S6 ELEV. EL ELO MACH RM BUILDING PERMIT 2-23-12 a 0 0 a 0 ,1 P to C 1048 / DD PRICING 10-31 -11 4 0 SD PRICING 8-8-11 C 0� P 2 P WP ISSUED FOR: DATE: OOP ELEV. OP OO P MACH. RM ® ELEV. J-4, ;' ,126 (4)CR MACH. RM CR (4) (`3 1086 O 2 2 Shaner Life Safety @ 0 O O - - Engineering 0 2 SB SB PO Box 1073, Frisco, Colorado 80443 2 2 (-ORRIDOF SB SB SHANERLS®COMCAST.NET, (970) 409-9082 116 STAIR D 0 0 1 11bA 0 o ELEV. � THESE DRAWINGS AND SPECIFICATIONS AND THE P C, ,,,, IDEAS, DESIGNS AND ARRANGEMENTS 1 S T FLOOR PLAN REPRESENTED THEREBY ARE AND SHALL REMAIN �U PROPERTY OF THE ARCHITECT, AND NO PART J P OTHERS,THEREOF SHALL BE COPIED, DISCLOSED TO SCALE: �H�� _ —O" / OTHERS, OR USED IN CONNECTION WITH ANY FLAG N 0 T E S . WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT❑ 0 P NOTES : THE ARCHITECT. V SUALE CWRITTEN ONTACT WI HS THESE ELEV. DRAWINGS OR SPECIFICATIONS SHALL MACH. RM z ® 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. 01 EXISTING FIRE ALARM ANNUNCIATOR TO BE CONSTITUTE CONCLUSIVE EVIDENCE OF REPLACED. ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN 1166 g(4) 2. A NEW FIRE ALARM SYSTEM SHALL BE PROVIDED DIMENSIONS ON THESE DRAWINGS SHALL HAVE �3 THROUGHOUT THE BUILDING. REFER TO SYSTEM �2 NOTIFIER ACCLIMATE DETECTORS WITH SOUNDER PRECEDENCE OVER SCALED DIMENSIONS. SPECIFICATIONS FOR DESIGN REQUIREMENTS. BASES SHALL BE PROVIDED. SMOKE SENSOR CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE SHALL ACTIVATE A SUPERVISORY CONDITION AT FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY THE FACP AND SOUND A LOCAL ALARM 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND VARIATIONS FROM THE DIMENSIONS AND ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE THROUGHOUT THE UNIT (TANDEM WIRE CONDITIONS SHOWN BY THESE DRAWINGS. ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE DETECTORS TOGETHER). THE HEAT SENSOR LOCATIONS, SYSTEM DESIGN AND INSTALLATION. SHALL ACTIVATE GENERAL ALARM IN THE BUILDING. SOUNDER BASES PROVIDE GENERAL 4. RUN FIRE ALARM WIRE IN NEW SOFFITS BUILT FOR ALARM SIGNAL IN UNITS. THE SPRINKLER UPGRADE. SOFFITS ARE NOTED ON THIS SHEET. O PROVIDE ELEVATOR RECALL AND POWER SHUNT FOR NEW ELEVATOR. I ST FLOOR OMONITOR SPRINKLER WATER FLOW/TAM PER FIRE ALARM PLAN SWITCH. OPROVIDE OUTSIDE HORN/STROBE ABOVE FIRE DEPT CONNECTION. COORDINATE WITH SPRINKLER CONTRACTOR. FA2 . 1 O W W STAIR E ❑ ❑ 'y V / STAIR G STAIR F ~� 210 206 ❑ ❑ ❑ o ❑ ❑ LH o ❑ ❑ � �/ 0 0 :III, ip ❑ ❑ ❑ O O ° O ❑ ❑ ❑ OSB OSB SB Q ❑ I AIF WOODSMALL r� LE 100 C STERLING 0 0 0 O 0 0 C'I 205 0 O h—I .B. E.B. O E.P E B. '..P. E.P O O O 1 °s6 O o s6 O STAIR H OSB OSg s6 o a o o Q � � o 0 - O 'D 0 O LARNED RAUCH RAUCH RAWSON O O O w W m ❑ 0 0 213 211 100 0 (D 209 207 J 0 a o a D 0 N o 13 00 00 00 � 0 w J V m \ ® x O O C� U m ¢ w O O O o ❑ ❑ ❑ ❑ O ? N a V 2 SB 1 OS SB O OSB OP Q °_ Z O O O O wKZN o 0 � ' O l� Q o 0 o Q ��,' ° \ O o ° O � Q.. O J w Z o 0 O 0 2 J O °SB °SB OSB OSB SB SB Q �O OO DO C� OD CORRIDOR O 0 Op Q 204 F p - I - — - — � o E.B. E.B O O OSB OSB 0 0 O O ELEV. OO OSB OSB O ° O° ? 2 44C C UNIT DE UGARTL OSB IDO SB SB ORRIDO OSB OSB CEO � OO 217 215 0000 .212 208 O °p STAIR A MAI DS C LOS. Op 204A 76 O O ° 204B SB SB s' ELEV. ELEV. 0 0 0 212c 2osc nom_ _ — BUILDING PERMIT 2-23-12 O 0 C � % DD PRICING 10-31 -11 �� 2 Ou OP Op STAIR TOWER A sD PRICING 8-8-1 1 OP LQ-1 MAIDS MAIDS � � ISSUED FOR: DATE. cL F STAIRC CL NOTES . FLAG NOTES . - - - IDO 21 AIR p F STAIR B 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. O NOTIFIER ACCLIMATE DETECTORS WITH SOUNDER 2088 08 BASES SHALL BE PROVIDED. SMOKE 16 2. ANEW FIRE ALARM SYSTEM SHALL BE PROVIDED DETECTOR SHALL ACTIVATE A SUPERVISORY THROUGHOUT THE BUILDING. REFER TO SYSTEM CONDITION AT THE FACP AND SOUND A LOCAL O SPECIFICATIONS FOR DESIGN REQUIREMENTS. ALARM THROUGHOUT THE UNIT (TANDEM WIRE 01 01 (D 3. TOGETHER). THE HEAT SENSOR Shaner Life Safety 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND SHALL ACTIVATE GENERAL ALARM IN THE O O O O ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE BUILDING. SOUNDER BASES PROVIDE GENERAL - - ring SB SB SB SB ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE ALARM SIGNAL IN THE UNIT PO Box 1073, Frisco, Colorado•80443 . LOCATIONS, SYSTEM DESIGN AND INSTALLATION. SHANERLS®COMCAST.NET; (970) 409-9082 0 0 � 0 STAIR TOWER C STAIR TOWER B 4 THE SPRINKLER UPGRADE. N 0 FIITS TARE NIOTED R O SWITCH. SPRINKLER WATER FLOW/TAM PER / ON THIS SHEET. i O O ELEV. 21 bC �( 'I THESE DRAWINGS AND SPECIFICATIONS AND THE �I���I IDEAS, DESIGNS AND ARRANGEMENTS OREPRESENTED THEREBY ARE AND SHALL REMAIN p PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL❑ ❑ BE COPIED, STAIR D OTHERS, OR USED N CONNECTION DISCLOSED WITH ANY MAIDS 21 bA WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF CL THE ARCHITECT. VISUAL CONTACT WITH THESE 216 P CONSTITUTE I OCONCLUSIVIEICATEVIDENCESHAOF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. STAIR TOWER D 2ND FLOOR PLAN SCALE: 1/8" = 1'-0" 2ND FLOOR FIRE ALARM PLAN FA2 . 2 0 w 0 STAIR E 302 � ►� rTl awl O V STAIR G — u 0 0 0 0 POLSTON ELY S AIR F a 307 O C 301 AA O O 308 O JO O 0 (D 00o F_ � (D ul w/D O g O SB 4— wio O ❑ O SCHULTE ,� s - STAIR H AUTENREITH BROWNING OLTHOF 310 a o Q Q o 0 0 319 316 313 (LOCKED) Q W X22 0 2 0 T_ __T. F'o 7 J 00 c o0 Do O O O 0 0 a o o o �00 2 p 00 0o Oo 00 C 1 � O " M w 2 m OSB SB wio wiD SB SB wio C P w o ° I� Fe �� ORRID( Ose OSB OSB OSB Q w /�\ O (�1\ O O O O O O /�\ O O o F Z ° M 1\�/// \\�// I O M 0 0 OSB OSB Sob CORRIDOR u Q DO C 2 O a0 � c 2 � O Q � oza U M z � D P p w K Z w ELEV. - 1 O O O O O 2 O ? O 306C �- II URSANER FARCUS OO S13 O2 SB ' SB (D SB OSB 0 S OSB OSB O 325 324 D P :1 ED O O 000— _ _ _ _0 0 0 0 ' 00 STAIR 2 p 306A w/o SB O OSB wD - ° ° MAIDS ELEV. ELEV. CLOS. O o � o O o 0 C 2 (D Op ao � a0 O MAIDS MAIDS OP CLO STAIR C CL S. STAIR B BUILDING PERMIT 2-23-12 3186 318A 3 312A DD PRICING 10-31 -11 SD PRICING 8-8-11 ISSUED FOR: DATE: O O O P - O O O — - SB SB SB SB NOTES : FLAG NOTES : 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. O NOTIFIER ACCLIMATE DETECTORS WITH SOUNDER j 0 0 BASES SHALL BE PROVIDED. SMOKE 2. A NEW FIRE ALARM SYSTEM SHALL BE PROVIDED DETECTOR SHALL ACTIVATE A SUPERVISORY i Shaner Life Safety THROUGHOUT THE BUILDING. REFER TO SYSTEM CONDITION AT THE FACP AND SOUND A LOCAL _ _ _ _ ring SPECIFICATIONS FOR DESIGN REQUIREMENTS. ALARM THROUGHOUT THE UNIT (TANDEM WIRE PO Box 1073, Frisco, Colorado 80443 ° 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND DETECTORS TOGETHER). THE HEAT SENSOR SHANERLS®COMCAST.NET, (970) 409-9082 ELEV. SHALL ACTIVATE GENERAL ALARM IN THE ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE BUILDING. SOUNDER BASES PROVIDE GENERAL 326C ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE ALARM SIGNAL IN THE UNIT. LOCATIONS, SYSTEM DESIGN AND INSTALLATION. 4. RUN FIRE ALARM WIRE IN NEW SOFFITS BUILT FOR OMONITOR SPRINKLER WATER FLOW/TAM PER P THE SPRINKLER UPGRADE. SOFFITS ARE NOTED SWITCH. ON THIS SHEET. MAI DS CLOS. STAIR D THESE DRAWINGS AND SPECIFICATIONS AND THE 326A REPRESENTED E DESIGNS THEREBY A EDAND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. 3RD FLOOR PLAN 3RD FLOOR SCALE: 1/8" = V-0" FIRE ALARM PLAN FA2 . 3 4 O I~� W W a�wll o V •D.S. • D.S. • D.S. • D.S. I Ds, D.S. O I I OLSTON I I s� I I ELY I a I I I I 1 O 407 401 1 D.S.• Il'I 11.4 I I I 1 l ON UP I--i D.S. L I — — — _D� L�. — — — — — — _ _D.S.• • O OSB AUTENREITH BROWNING SCHULTF O 1 S O a a 419 OSB 416 O O OLTHOF 410 O 1 I �1 SB SB 413 0 o O 2 O Q Q O 0 I I O I I � se � � 1 se ,. I � � M w O 0 N D.S. w z m H \J 0 � o OSB Q w o M 1 o � wx o ? SB O2 SB o O 1 0 1 w Z � .D.S.• 1 (D F w Z M 1 ° ° ° ° I I ❑ ° I w � a ° Q _ d � I I I I URSANFR FARCUS 1 _ _ _ 425 OSB OSB 424 I I I 1 i D.S. I I �1 ❑ ❑ 1 ❑ ❑ ❑ 1 •D.S I D.S. IL - - - - - - - - - - - � � - - - - - - - - - - —1 L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � 1 j0SEI :� OSB 1 0 O - - - - - - - - - - - - - - - - - - - - - - - SB .D.S. • o 1 a - I O � I I 0 O < j,— O BUILDING PERMIT 2-23-12 1 DD PRICING 10-31 -11 I I I 1 1 SD PRICING 8-8-11 NOTES : ISSUED FOR: DATE: 1 1 FLAG NOTES : OSB 1 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. O TYPICAL UNIT FIRE ALARM LAYOUT. NOTIFIER O 2. A NEW FIRE ALARM SYSTEM SHALL BE PROVIDED ACCLIMATE DETECTORS WITH SOUNDER BASES THROUGHOUT THE BUILDING. REFER TO SYSTEM SHALL BE PROVIDED. SMOKE DETECTOR SPECIFICATIONS FOR DESIGN REQUIREMENTS. SHALL ACTIVATE A SUPERVISORY CONDITION AT THE FACP AND SOUND A LOCAL ALARM 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND THROUGHOUT THE UNIT (TANDEM WIRE F I ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE DETECTORS TOGETHER). THE HEAT SENSOR Shaner Life Safety 1 ° ° 01 ° I ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE SHALL ACTIVATE GENERAL ALARM IN THE _ I I J LOCATIONS, SYSTEM DESIGN AND INSTALLATION. BUILDING. SOUNDER HBASES UNIT.PROVIDE GENERAL PO Box 1073, Frisco, Colorado SHANERLS®COMCAST.NET; (970) 409-909-90 82 4. RUN FIRE ALARM WIRE IN NEW SOFFITS BUILT FOR THE SPRINKLER UPGRADE. SOFFITS ARE NOTED — — -1 ON THIS SHEET. O SPRINKLER FEED TO ATTIC DRY PIPE SYSTEM. MONITOR WATERFLOW, TAMPER AND LOW Al SWITCH. FIELD COORDINATE EXACT LOCATION •D.S. WITH FIRE PROTECTION CONTRACTOR. THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE •°'S' • DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. 4TH FLOOR PLAN 4TH FLOOR FIRE ALARM PLAN SCALE: 1/8" = 1'-0" FA2 . 4 FIRE PROTECTION GENERAL NOTES ° BASEMENT WALL. 1 . THIS BUILDING IS TO BE PROVIDED WI I H A FIRE SPRINKLER SYS I EM C IGNFD, INSTALLED AND TESTED o 0 PER NEPA 13 REQUIREMENTS AND PER THE AUTHORITY HAVING JURISDIC ION. 2. THE BUILDING IS CURRENTLY PARTIA'TY SPRINKLERED. THE EXISTING EIRE ENTRY WILL REMAIN AND THRUST BLOCK AT 1 ELL. SUPPLY THE AREAS TO BE SPRINKLERED. FIRE PROTECTION CONTRACTOR SHALL RECONDITION FIRE sEPVi,�� o PROVIDE OFFSET IN PIPE 3 ELLS OR PIPE MOVEMENT.NT. ENTRY TO ENSURE ALL COMPONEKTS HAVE REQUIRED INTEGRITY. ° 3. ALL MATERIALS, DEVICES AND HANGERS USED ON THIS PROJECT SHALL BE UL LISTED FOR USE IN FIRE PROTECTION SYSTEMS. ° 4. ALL PIPING SHALL COMPLY WITH PROJECT SPECIFICATIONS. PIPE SIZING IS TO BE CALCULATED BY THE < < ° WALL SLEEVE; I.D. = 4" FIRE PROTECTION CONTRACTOR, PROVEN BY HYDRAULIC CALCULATIONS, IN ACCORDANCE WITH NEPA 13. ° o LARGER THAN O.D. of PIPE. 5. FREEZE PROTECTION IS THE RESPONSIB IHTY OF THE OWNER IN AREAS WHERE AN ANTI-FREEZE OR DRY p SYSTEM ARE NOT INSTALLED. EIRE PROTECTION CONTRACTOR SHALL VERIFY CONDITIONED TEMPERATURE 0 CAULK W/ 2 PART OF ALL AREAS PRIOR TO SYSTEM DESIGN. ° POLYSULFIDE CAULKING. 6. MAXIMUM STORAGE HEIGHT PERMITTED IN STORAGE ROOMS OR AREAS IS 12' OF MISCELLANEOUS AND 5' ° o OF PLASTICS. o v 7. THE OWNER SHALL MAINTAIN A CLEAR 18" BETWEEN THE CEILING AND THE TOP OF ANY STORAGE OR TIE RODS; TYP. O OTHER OBSTRUCTIONS. RjL-u 8, DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER C.I. HUB To FLANGED TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. UUUU ADAPTER. r 9. SPRINKLER HEADS TO BE COORDINATED WITH ALL LIGHTING FIXTURES AND CEILING SYSTEMS. r 10. OFFSET PIPING, DUCTWORK, ETC . AS NECESSARY TO ACCOMMODATE STRUCTURE, BEAMS, COLUMNS, AND EXISTING EQUIPMENT. ° ° ° o 11 . PLANS ARE CONCEPTUAL ONLY. SPRINKLER CONTRACTOR SHALL REFER TO SPECIFICATIONS AND PREPARE THRUST BLOCK. ° ° ° ° ° SHOP DRAWINGS FOR SUBMITTAL TO THE AUTHORITY HAVING JURISDICTION, OWNER AND ARCHITECT � BSMT. FLOOR. BEFORE ANY PIPE IS HUNG. , ° ° ° o v ° O 12. CONTRACTOR SHALL TAKE NO ADVANTAGE OF ANY APPARENT ERROR OR OMISSION AND SHALL IMMEDIATELY NOTIFY ARCHITECT. ARCHITECT WILL THEN MAKE SUCH CORRECTIONS AND/OR w INTERPRETATIONS AS MAY BE NECESSARY FOR FULFILLING INTENT OF PLANS AND SPECIFICATIONS. WATER & FIRE ENTRY DIAGRAM 13. COORDINATE ALL WORK WITH OTHER TRADES. 14. PROVIDE OWNER WITH THE NECESSARY INSTRUCTION MANUALS FOR THE UPKEEP 0 HE SYSTEM. NO SCALE 15. INSTALL ONLY NEW SDRINKI ERS AND MATERIALS. 16. FIRESTOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, CEILINGS, FLOORS, ROOFS, ETC . TO MAINTAIN FIRE 18" DOWNSTREAM OF ELBOW. RATING. o \ 17. PROVIDE ACCESS PANELS TO ALL VALVES LOCATED ABOVE NON-ACCESSIBLE CEILINGS AND CHASES. WALL cABIN� iF V 18. HYDROSTATICALLY TEST ALL SYSTEM PIPING AT 200 PSI FOR TWO HOURS OR AT 50 PSI ABOVE SYSTEM REQUIRED. OPERATING PRESSURE, WHICHEVER IS GREATER. EIRE LINE TO 1 19. PROVIDE A STOCK OF SPARE SPRINKLERS OF EACH STYLE, TYPE AND TEMPERATURE RATING, ALONG WITH SPRINKLERS. I--d A SPRINKLER WRENCH OF EACH STYLE, AT THE MAIN RISER. SUPERVISORY SWIT: �T1 ^ FLOW SWITC H. 20. COORDINATE ELECTRICAL REQUIREMENTS FOR MONITORING WATERFLOW AND TAMPER SWITCHES WITH THE � ELECTRICAL CONTRACTOR. REDUCER. ~� 21 . COORDINATE THE LOCATIONS OF AUXILIARY DRAINS WITH THE ARCHITECT. f FIRE RISER. 22. UPON COMPLETION, FIRE PROTECTION CONTRACTOR SHALL PROVIDE AS-BUILT, RED-LINED DRAWINGS o SHOWING ANY REVISIONS TO THE SUBMITTED PIPING SYSTEM INCLUDING THE LOCATIONS OF ALL DRAINS SIGHT GLASS. AND VALVES INSTALLED DURING THE INSTALLATION OF THE PIPING. EIRE DRAIN PIPE. 23. SPRINKLER CONTRACTOR SHALL PROVIDE A MATERIAL SUBMITTAL FOR PIPE, SPRINKLER HEADS, VALVES TEST VALVE. AND OTHER MATERIAL AS PART OF THEIR SUBMITTAL. 24. SPRINKLER CONTRACTOR SHALL INCLUDE HYDRAULIC DESIGN INFORMATION AS PART OF THEIR SUBMITTAL INCLUDING HYDRAULIC CALCULATIONS AND PIPE SIZES. " UNION BRASS NOTE: ORIFICE DISC WITH FIRE SPRINKLER A HOLE EQUAL TO l PIPING SHALL BE HYDRAULICALLY THE FLOW OF ONE SIZED. SPRINKLER HEAD. O AUXIIIARY DRAIN 0 VALVE. FIRE SPRINKLER CONTROL STATION DIAGRAM NO SCALE U Z TO BUILDING o 0 FIRE DEPT. CONNECTION. WET ZONES TO ATTIC DRY ZONES Q � � z O o Z EXTERIOR WALL. FF FF FF FF FF FF w - U - Z Q M z AIR OMPRESS TEST VALVE VA BALL iNI FLOW SWITC H BALL DRIP—/ –a FF VALVE. DRAIN VALVE; PIPE TO FLOOR DRAIN, TYP. DOUBLE CHECK TYPE BAC KFLOW PREVENTER. TAMPER SWITCHES ON VALVES. BUILDING PERMIT 2-23-12 DD PRICING 10-31 -11 FIRE SERVICE FLANGE. FLG, SD PRICING 8-8-11 ISSUED FOR: DATE: FIRE ENTRY PIPING DIAGRAM NO SCALE Shaner Life Safety PO Box 1073, Frisco, Colorado 80443 SHANERLS®COMCAST.NET, (970) 409-9082 THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. FIRE SPRINKLER COVER SHEET FS1 . 0 O W W W w — — — — — ——— — — — — — — — — — — — HELPHENSTINE WHITE CHANNEL 003 002 001 � � O MCINTYRE 004 a � O a: 0 O0 � � ❑ 0 a 0 0 0 a o e e o a Q 005 (E) KITCHEN W D W D W D W D 015 • �������� (N) STAIR D OlOA 1 (E) CORRIDOR (E) MECH. (E) BREAK (E) LAUNDRY oob ROOM ROOM R M ❑ z 007 009 008 — N W H � O I — LLw m z I v w O � � z a Q I I I I I I (E) OFFICE I 014 I I I I I I I I I BUILDING PERMIT 2-23-12 O DD PRICING 10-31 -11 I (E) WILDWOOD SD PRICING 8-8-11 � FLAG NOTES : ROOM ISSUED FOR: DATE: 013 04" FIRE ENTRY WITH BACKFLOW PREVENTER, EXISTING TO REMAIN. REWORK ENTRY AS NEEDED TO ACCOMMODATE CHANGES TO SPRINKLER SYSTEM. O2 FIRE PROTECTION CONTRACTOR TO REWORK Sh a n e r Life Safety SPRINKLER LAYOUT IN THIS AREA TO ACCOMMODATE STRUCTURAL CHANGES. 0 0 O PO Box 1073, Frisco, Colorado•80443 COORDINATE WITH STRUCTURAL DRAWINGS. a SHANERLS®COMCAST.NET; (970) 409-9082 0 0 NOTES : FIRE PROTECTION SYMBOLS 1. EXISTING CORRIDORS AND COMMON AREAS ARE SPRINKLERED. Q O CONTRACTOR SHALL CONNECT TO EXISTING PIPING IN COMMON THESE DRAWINGS AND SPECIFICAT IONS AND THE SPRINKLER HEAD — STANDARD UPRIGHT, CHROME AREAS TO FEED UNITS AND OTHER NEW AREAS. IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN ® SPRINKLER HEAD — CONCEALED PENDENT, WHITE 2. IN NON—CONDITIONED SPACES, PROVIDE AN ANTIFREEZE LOOP PROPERTY OF THE ARCHITECT, AND NO PART OR DRY PIPE SPRINKLER SYSTEM. PROVIDE FREEZE PROTECTION THEREOF SHALL BE COPIED, DISCLOSED TO ® SPRINKLER HEAD — RECESSED SIDEWALL, WHITE WHERE NECESSARY. OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN ® SPRINKLER HEAD — DRY SIDEWALL, CHROME 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND PREPARED WITHOUT THE WRITTEN CONSENT OF ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE THE ARCHITECT. VISUAL CONTACT WITH THESE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER, DRAWINGS OR SPECIFICATIONS SHALL SYSTEM AND STANDPIPE DESIGN AND INSTALLATION. CONSTITUTE CONCLUSIVE EVIDENCE OF NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND 4. SPRINKLER SYSTEM IN ALL EXISTING AREAS SHALL BE UPGRADED DIMENSIONS ON THESE DRAWINGS SHALL HAVE ENGINEER. COORDINATE 'TYPE AND FINISH WITH INTERIORS. ALL HEADS TO PROVIDE A SYSTEM COMPLIANT WITH NFPA 13 AND VAIL FIRE PRECEDENCE OVER SCALED DIMENSIONS. SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE EXTENDED COVERAGE HEADS WHERE APPLICABLE. DEPARTMENT REQUIREMENTS. BASEMENT FLOOR PLAN FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY 5. SPRINKLER PIPE SHALL BE RUN IN SOFFITS AS SHOWN. SCALE: 1/8" = 1'-0" VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER HEADS ON DECKS SHALL BE DRY TYPE. 7. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. 8. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL BASEMENT ENGINEER. FIRE PROTECTION PLAN 9. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. 10. INTERSTITIAL SPACES BETWEEN FLOOR AND CEILINGS SHALL BE FILLED WITH BLOWN IN INSULATION. SPRINKLER PROTECTION IS NOT REQUIRED. FS2 . 0 O O El E - ----------- 0 ° ❑ ❑ ❑ 5 ° MCINTYRE TnMPI,'INS HU7FLLA F-r - 2 105 103 O O 101 O 0 0 JJ 1 1 )D100B 0 0 2 O � � 2 I � � CHAN MITNICK ABRAMS BERMUDEZ O _ 0 � 113 111 109 log 'O OE �O O 0 ri 1 0 To] 0- 7 1� 1 1 Wl 71 LL� V7 o O rol o o O O� o D DO 00 no OE ►-1 O L O 1 L li 1� 1 11 1 1 F===l I 0 0 0 3 O � 1 1 I�1 2 CHAN YEE 2 - a 117 115 O O 0 1 0 1 00 O 0 Q L7 o ° 2 2 `o Do 00 0 z w a o � U z O 0 -I 1 0 4' DRY STANDPIPE O w (BURY UNDERGROUND) 4" DRY STANDPIPE (BURY UNDERGROUND) U M EXISTING PIPING TO 1 w a Z � SPRINKLER SYSTEM,TO � � w z REMAIN. _ � a w U Z J J 5 2 FREESTANDING FDC TO REMAIN. ° ° FDIC FOR MANUAL DRY STANDPIPE. --jJ NOTES : FLAG NOTES : 4" DRY STANDPIPE 1. EXISTING CORRIDORS AND COMMON AREAS ARE SPRINKLERED. EXISTING SPRINKLER RISER TO REMAIN. O (BURY UNDERGROUND) CONTRACTOR SHALL CONNECT TO EXISTING PIPING IN COMMON O REMOVE 1-1/2" STANDPIPE CONNECTION. AREAS TO FEED UNITS AND OTHER NEW AREAS. ENSURE WATERFLOW AND TAMPER SWITCHES 2. IN NON—CONDITIONED SPACES, PROVIDE AN ANTIFREEZE LOOP ARE PROVIDED AT ALL FLOOR CONTROL O OR DRY PIPE SPRINKLER SYSTEM. PROVIDE FREEZE PROTECTION STATIONS. WHERE NECESSARY. BUILDING PERMIT 2-23-12 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND O NEW CLASS I T2 ") MANUAL DRY STANDPIPE, DD PRICING 1 -31 -1 1 TYP OF ALL STAIRS ON ALL FLOORS. ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE SD PRICING 8-8-11 PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER, EXISTING CORRIDORS AND COMMON AREAS 5 SYSTEM AND STANDPIPE DESIGN AND INSTALLATION. O ARE SPRINKLERED. EXISTING PIPING SHALL ISSUED FOR: DATE: 4. SPRINKLER SYSTEM IN ALL EXISTING AREAS SHALL BE UPGRADED REMAIN. REPLACE HEADS AS NECESSARY. TO PROVIDE A SYSTEM COMPLIANT WITH NFPA 13 AND VAIL FIRE PROVIDE THRUST BLOCKS ON DRY STANDPIPE DEPARTMENT REQUIREMENTS. O RUNS, IN ACCORDANCE WITH TOWN OF VAIL 5. SPRINKLER PIPE SHALL BE RUN IN SOFFITS AS SHOWN. REQUIREMENTS. I DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER O COORDINATE UNDERGROUND STANDPIPE RUNS + HEADS ON DECKS SHALL BE DRY TYPE. WITH CIVIL AND UTILITY DRAWINGS. Sh I IGI1Pr LIP SCIfP I,I 7. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. _ Protection PO Box 1073, Frisco, Colorado 80443 8. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. SHANERLS®COMCAST.NET, (970) 409-9082 BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL ENGINEER. 9. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. 10. INTERSTITIAL SPACES BETWEEN FLOOR AND CEILINGS SHALL BE FILLED WITH BLOWN IN INSULATION. SPRINKLER PROTECTION IS NOT REQUIRED. THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS FIRE PROTECTION SYMBOLS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART Q SPRINKLER HEAD — STANDARD UPRIGHT, CHROME THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY ® SPRINKLER HEAD — CONCEALED PENDENT, WHITE WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ® SPRINKLER HEAD — RECESSED SIDEWALL, WHITE THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL ® SPRINKLER HEAD — DRY SIDEWALL, CHROME CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE FOR ALL DIMENSIONS AND CONDITIONS ON THE SPRINKLER CONTRACTOR, SUBJECT TO APPROVAL BY ARCHITECT AND JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY ENGINEER. COORDINATE TYPE AND FINISH WITH INTERIORS. ALL HEADS VARIATIONS FROM THE DIMENSIONS AND SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE CONDITIONS SHOWN BY THESE DRAWINGS. EXTENDED COVERAGE HEADS WHERE APPLICABLE. 1 ST FLOOR FIRE PROTECTION PLAN 1 ST FLOOR PLAN SCALE: 1/81$ = 1'-0" FS2 . 1 STAIR E 202 STAIR G STAIR F 210 206 _ ❑ ❑ r ❑ q .B. E13 B. L.P. I� ❑ ❑ ❑ I� LAIR WOODSMALL I+) O Eool� S TERLING 2 0 NO' 205 �, ' � ® - 2 STAIR H 2 0 0 0 1 0 o o ° o 0 2,4 LARNED RAUCH RAUCH RAWSON 0 0 0 M--I 213 211 0 0 209 207 a 0 0 a a 0�-o 0 00 00 0 v Q O 17 n ❑ ❑ ❑ ❑ o a Q00000 Oo O 0 ® 0 0 ® 0 U0 00 a0 00 ORRIDO Q f1 204 �✓ LJ 3 M W w o 0 y p 0 R N U M .B. E.B. -F'. E.13 W Z � p � ~ O o 2 Q w o M U N J ELEV. e„ 0 DE UGARTE IDO 2o4c 2 N o z UNIT — Q - - o 2�5 100:001 ORRIDO 2os 0 J Z o 0 0 0 0 � w � STAIR A ---- - ° ® MAIDS CLOS. 2o4A 2046 ELEV. ELEV. i — ° o � O � ® o ° 0 2 2 U0 0a o STAIR TOWER A MAIDS MAIDS ID CLOS. STAIR C CLOS. STAIR B 1 2126 212A 2086 208A 16 BUILDING PERMIT 2-23-12 o 0 0 o STAIR TOWER C STAIR TOWER B DD PRICING 10-31 -11 • FLAG NOTES : SD PRICING 8-8-11 1. EXISTING CORRIDORS AND COMMON AREAS ARE SPRINKLERED. O EXISTING SPRINKLER RISER TO REMAIN. ISSUED FOR: DATE: CONTRACTOR SHALL CONNECT TO EXISTING PIPING IN COMMON REMOVE 1-1/2" STANDPIPE CONNECTION. AREAS TO FEED UNITS AND OTHER NEW AREAS. ENSURE WATERFLOW AND TAMPER SWITCHES ELEV. 2. IN NON–CONDITIONED SPACES, PROVIDE AN ANTIFREEZE LOOP ARE PROVIDED AT ALL FLOOR CONTROL 21 bC OR DRY PIPE SPRINKLER SYSTEM. PROVIDE FREEZE PROTECTION STATIONS. 2 WHERE NECESSARY. 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND O TYP O CLASS LL IS(2 1"� ON UAL DRY FLOORS. STAIR D ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE Shaner Ofe Safety ° PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER, MAIDS 216A SYSTEM AND STANDPIPE DESIGN AND INSTALLATION. EXISTING CORRIDORS AND COMMON AREAS _ _ _ _ _ _ _ O CLOS. ARE SPRINKLERED. EXISTING PIPING SHALL PO Box 1073, Frisco, Colorado 80443 4. SPRINKLER SYSTEM IN ALL EXISTING AREAS SHALL BE UPGRADED REMAIN. REPLACE HEADS AS NECESSARY. SHANERLS®COMCAST.NET, (970) 409-9082 2166 TO PROVIDE A SYSTEM COMPLIANT WITH NFPA 13 AND VAIL FIRE DEPARTMENT REQUIREMENTS. 5. SPRINKLER PIPE SHALL BE RUN IN SOFFITS AS SHOWN. 2ND FLOOR PLAN 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER HEADS ON DECKS SHALL BE DRY TYPE. SCALE: 1/8" = V-0" 7. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. STAIR TOWER D THESE DRAWINGS AND SPECIFICATIONS AND THE 8. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. IDEAS, DESIGNS AND ARRANGEMENTS BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL REPRESENTED THEREBY ARE AND SHALL REMAIN ENGINEER. PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO 9. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN 10. INTERSTITIAL SPACES BETWEEN FLOOR AND CEILINGS SHALL BE PREPARED WITHOUT THE WRITTEN CONSENT OF FILLED WITH BLOWN IN INSULATION. SPRINKLER PROTECTION THE ARCHITECT. VISUAL CONTACT WITH THESE IS NOT REQUIRED. DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FIRE PROTECTION SY M B 0 LS FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY Q VARIATIONS FROM AND SPRINKLER HEAD – STANDARD UPRIGHT, CHROME CONDITIONS S OWNTHBY THESE DIMENSIONS DRAWING. ® SPRINKLER HEAD – CONCEALED PENDENT, WHITE ® SPRINKLER HEAD – RECESSED SIDEWALL, WHITE ® SPRINKLER HEAD – DRY SIDEWALL, CHROME 2ND FLOOR NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE FIRE PROTECTION PLAN SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND ENGINEER. COORDINATE 'TYPE AND FINISH WITH INTERIORS. ALL HEADS SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE EXTENDED COVERAGE HEADS WHERE APPLICABLE. FS2 . 2 4 O 13 AL w ll M--� ❑ ❑ - I ❑ LL_ L ❑ ❑ ❑ ❑ L^� ° ° ELY ^� POLSTON 4 4 30 0 00 307 2 O O 3 00 3 3 00 - V 1 ►—� I III Lr— - ° _ a ® o Ll 1 ' W/D \ 2 W/D AUTENREITH 4 2 0 BROWNING OLTHOF 4 SCHULTE O lv J 319 316 F71 0 �3 3 3 3 Do 0u Do — - O O 60' O O o 0 0 0 05 O O 0 0 O O ooa I �J 1 v ❑ I ❑ ❑ _ ° E E W/D z o O o o O Q � w Do 6 0D �0 6 oD Z � o ° a o z 5 � ~ Q w Z M 1 1 w H J � Z y 2 Q F _rn U RSAN E R 10 10— Lo 325 D S FAR U O Ll C 0 O O a 324 ° I ° I I ° 00 0O L u �1R E D 0 0 0 0 ® 0 o a 0 0 6 0 2 2 D D Ix o � o NOTES : FLAG NOTES : BUILDING DIICNGRMIT 10-31 -11 1. EXISTING CORRIDORS AND COMMON AREAS ARE SPRINKLERED. O EXISTING SPRINKLER RISER TO REMAIN. SD PRICING 8-8-11 CONTRACTOR SHALL CONNECT TO EXISTING PIPING IN COMMON REMOVE 1-1/2" STANDPIPE CONNECTION. AREAS TO FEED UNITS AND OTHER NEW AREAS. ENSURE WATERFLOW AND TAMPER SWITCHES ISSUED FOR: DATE: ® ® 2. IN NON—CONDITIONED SPACES, PROVIDE AN ANTIFREEZE LOOP ARE PROVIDED AT ALL FLOOR CONTROL OR DRY PIPE SPRINKLER SYSTEM. PROVIDE FREEZE PROTECTION STATIONS. PROVIDE ACCESS PANEL. WHERE NECESSARY. \> 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND O NEW CLASS 1 (2 �") MANUAL DRY STANDPIPE, ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE TYP OF ALL STAIRS ON ALL FLOORS. ' PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER, SYSTEM AND STANDPIPE DESIGN AND INSTALLATION. O S SOFFIT R PIPE TO LOFT ABOVE RUN IN RISER 4. SPRINKLER SYSTEM IN ALL EXISTING AREAS SHALL BE UPGRADED Shaner Life Safety TO PROVIDE A SYSTEM COMPLIANT WITH NFPA 13 AND VAIL FIRE O PROVIDE A SPRINKLER HEAD AT THE TOP OF - DEPARTMENT REQUIREMENTS. FIREPLACE FLUE CHASES. PO Box 1073, Frisco, Colorado 80443 SHANERLS®COMCAST.NET, (970) 409-9082 5. SPRINKLER PIPE SHALL BE RUN IN SOFFITS AS SHOWN. O EXISTING CORRIDORS AND COMMON AREAS 5 ARE SPRINKLERED. EXISTING PIPING SHALL ------- 2 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER HEADS ON DECKS SHALL BE DRY TYPE. REMAIN. REPLACE HEADS AS NECESSARY. 3RD FLOOR PLAN 7. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. O ACCESS PANEL TO ATTIC SPACE (ROOF OVERFRAMING). PROVIDE DRY PIPE SYSTEM IN SCALE: 1/8" = 1 '-0" 8. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. ATTIC SPACE. INSTALL DRY PIPE VALVE AND BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL COMPRESSOR AT FIRE ENTRY IN BASEMENT ENGINEER. MECHANICAL ROOM. THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS 9. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. REPRESENTED THEREBY ARE AND SHALL REMAIN I i PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO 10. INTERSTITIAL SPACES BETWEEN FLOOR AND CEILINGS SHALL BE OTHERS, OR USED IN CONNECTION WITH ANY FILLED WITH BLOWN IN INSULATION. SPRINKLER PROTECTION WORK OR PROJECT FOR WHICH THEY HAVE BEEN IS NOT REQUIRED. PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE FIRE PROTECTION SYMBOLS JOB,AND THIS OFFICE MUST BE NOTIFIED ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SPRINKLER HEAD — STANDARD UPRIGHT, CHROME ® SPRINKLER HEAD — CONCEALED PENDENT, WHITE ® SPRINKLER HEAD — RECESSED SIDEWALL, WHITE ® SPRINKLER HEAD — DRY SIDEWALL, CHROME 3RD FLOOR NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE FIRE PROTECTION PLAN ENGINEER• COORDINATEER'YPE AND FINNISHP WITTHINTERIORS HALL HEADS SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE EXTENDED COVERAGE HEADS WHERE APPLICABLE. FS2 . 3 0 W w D S D S. Fri D.S. y D.S. POLSTON ELY I a 407 3 401 / O O D.S.• I I I I I I I DN UP I� D 1 • D.S. I I 1 I D:. I I I I I o a V L AUTENREITH BROWNING SCHULTE I 419 O 416 OLTHOF O 410 • 0• e 413 O O O 0 0 0 D.S. •D.S. D.S.• 1 1 L - - - J - - - - - - - - � I u z D.5. w m I I LL > o 0 c 0 0 o U w 0 I D.S. 0 O O Q O o o O Q O o o F__ -7 Z I I � M _ w � Z � L.D.S.. F u w Z o I I ❑ ❑ ❑ ❑ I I ❑ ❑ I w � w I I I I Fu F— -- — — — — — — — — L— — — — — — — — — — — — -- --i t I I I URSANER FARCUS 425 424 I O I I i. D.S.. I I I _ L QX - - C D.S. IL — — __1 L— — — — — -I — — J I I I I I I O — O C 0 0 s. . . . I O I I 0 ° I I O BUILDING PERMIT 2-23-12 DD PRICING 10-31 -11 NOTES : FLAG NOTES : I I I SD PRICING 8-8-11 1. EXISTING CORRIDORS AND COMMON AREAS ARE SPRINKLERED. ISSUED FOR: DATE: CONTRACTOR SHALL CONNECT TO EXISTING PIPING IN COMMON 01 SPRINKLER RISER UP FROM BELOW. AREAS 2. NON T UNITS T UNCONDITIONED PROVIDE CONDITIIONEDSPACES,, PROVIDE AN A TIFREEZE LOOP O SYSTEM FOR ROOF OVER RAM NG PIPE AREAS. N OR DRY PIPE SPRINKLER SYSTEM. PROVIDE FREEZE PROTECTION REFER TO STRUCTURAL PLANS FOR DETAILS WHERE NECESSARY. ON ROOF OVERFRAME AREAS. 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE O3 PROVIDE A SPRINKLER HEAD AT THE TOP OF h + PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER, FIREPLACE FLUE CHASES. S y ❑ ❑ ❑ ❑ SYSTEM AND STANDPIPE DESIGN AND INSTALLATION. _ _ _ _ _ _ _ _ _ _ — — _ _ _ _ _ _ _ _ _ _ _ _ J 4. SPRINKLER SYSTEM IN ALL EXISTING AREAS SHALL BE UPGRADED Po Box 1073, Frisco, Colorado 80443 TO PROVIDE A SYSTEM COMPLIANT WITH NFPA 13 AND VAIL FIRE SHANERLS®COMCAST.NET; (970) dos—sods DEPARTMENT REQUIREMENTS. — — — — — — — — — 5. SPRINKLER PIPE SHALL BE RUN IN SOFFITS AS SHOWN. �D.S. 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER 4TH FLOOR PLAN HEADS ON DECKS SHALL BE DRY TYPE. SCALE: 1/8" = 1'-0" 7. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. 8. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. THESE DRAWINGS AND SPECIFICATIONS AND THE BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL IDEAS, DESIGNS AND ARRANGEMENTS ENGINEER. REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART 9. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. THEREOF SHALL BE COPIED, DISCLOSED OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN 0 10. INTERSTITIAL SPACES BETWEEN FLOOR AND CEILINGS SHALL BE PREPARED WITHOUT THE WRITTEN CONSENTOF FILLED WITH BLOWN IN INSULATION. SPRINKLER PROTECTION THE ARCHITECT. VISUAL CONTACT WITH THESE D.S. • IS NOT REQUIRED. DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. FIRE PROTECTION SYMBOLS © SPRINKLER HEAD — STANDARD UPRIGHT, CHROME ® SPRINKLER HEAD — CONCEALED PENDENT, WHITE ® SPRINKLER HEAD — RECESSED SIDEWALL, WHITE ® 4TH FLOOR SPRINKLER HEAD — DRY SIDEWALL, CHROME FIRE PROTECTION PLAN NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND ENGINEER. COORDINATE fiYPE AND FINISH WITH INTERIORS. ALL HEADS SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE EXTENDED COVERAGE HEADS WHERE APPLICABLE. FS2 . 4 O O B 000 O O G O O K L 0 0 0 0 Q O (D 0- O O W 0 0 -1 t �_mlll oo rt W O n rr�ll O V O � w o d � O 1 _ z . w Q v � w O o V • , ~ w z _ Q n O w z w Q J' /X � 12:12 12:1 L N N 12:12 12 12 N J o N N 1 O 1 BUILDING PERMIT 2-23-12 DD PRICING 10-31 -11 NOTES : FLAG NOTES : SD PRICING 8-8-11 1. EXISTING CORRIDORS AND COMMON AREAS ARE SPRINK,LERED. Oj UNCONDITIONED SPACE. PROVIDE A DRY PIPE ISSUED FOR: DATE: CONTRACTOR SHALL CONNECT TO EXISTING PIPING IN COMMON SYSTEM FOR ROOF OVERFRAMING AREAS. AREAS TO FEED UNITS AND OTHER NEW AREAS. REFER TO STRUCTURAL PLANS FOR DETAILS 2. IN NON—COND TI N ED SPA ES, PR VIDE AN ANTIFREEZE LOOP ON ROOF OVERFRAME ARE S. OR DRY PIPE SPRINKLER S STEM. PROVIDE FREEZE PROTECTION WHERE NECESSARY. 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE Shaner Life Safety PROTECTION ONTRACTOR IS RESPONSIBLE FOR SPRINKLER, --- SYSTEM AND TANDPIPE DESIGN ND INSTALLATION. _ _ lo 4. SPRINKLER S STEM IN ALL EXISTI G AREAS SHALL BE UPGRADED / Po Box 1073, Frisco, Colorado•80443 • TO PROVIDE A SYSTEM COMPLIANT WITH NFPA 13 AND VAIL FIRE SHANERLS®COMCAST.NET; (s�o) 4os—soar O DEPARTMENT REQUIREMENTS. 5. SPRINKLER PIPE SHALL BE RUN IN SOFFITS AS SHOWN. • 12:12 121 6. DECKS SHALL BE SPRINKLERED A SHOWN. SPRINKLER \ N Gq! y N 4TH FLOOR PLAN HEADS ON DECKS SHALL BE DRY TYPE. �P� N SCALE: /8" = 1'-0" 7. SPRINKLER SYSTEM SHALL BE DESIGNED ER NFPA 13: O _ 12.12 12 12 8. COORDINATE ALL PIPE RUNTS WITH STRUCTURAL DRAWINGS. THESE DRAWINGS AND SPECIFICATIONS AND THE BEAM PENETR TIONS SHALL BE C ORDINATED WITH STRUCTURAL IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN N JP F� N ENGINEER. PROPERTY OF THE ARCHITECT, AND NO PART N N THEREOF SHALL BE COPIED, DISCLOSED TO 9. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN 10. INTERSTITIAL SPACES BETWEEN FLOOR AND CEILINGS SHALL BE PREPARED WITHOUT THE WRITTEN CONSENT OF g — FILLED—WITH BLOWN IN FNSVLATIOW--SPRINKLER PROTECTION � THE ARCHITECT. VISUAL CONTACT WITH THESE O IS NOT REQUIRED. DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF I ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. i ROOF FIRE PROTECTION PLAN I O B.1 O (E) O 8 O 8 lO (Do J.9 O a O 9 G 0.9 O 8 O O O U.9 O 00 FS2 . 5 LEGEND: SYMBOL DEVICE DESCRIPTION 4" 36" FACP N� MINIMUM Fire Alarm Control Panel FINISHED CEILING ? P DIFFUSER 4" MIN TO TOP CEILING MOUNTED MIN 6" ANN LCD Annunciator 12" MAX TO BOTTOM SMOKE DETECTOR i MEASURE FROM TOP OF DEVICE E]< WALL MOUNTED AUDIBLE DEVICE BPS �P Booster Power Supply 96" MAX (TOP OF LENS) WALL MOUNTED WALL MOUNTED VISUAL OR AUDIBLE/ DEVICE Manual Pull Station ~� SMOKE DETECTOR F ,Q, / 80" MIN (BOTTOM OF LENS) O NOT LESS THAN P Photoelectric Smoke Detector 90" ABOVE MEASURE TO TOP OF CABINET FACP FIRE ALARM CONTROL PANEL ® Heat Detector (fixed) ENTIRE LENS SHALL BE WITHIN 80"-96" MEASURE TO TOP OF UNIT RT- LCD LCD ANNUNCIATOR Duct Detector w/Test Switch 72„ TO CENTER OF DEVICE RT DUCT DETECTOR TEST STATION I>M Horn/Strobe, wall mount NORTH BUILDING TO CENTER OF DEVICE ❑ w (EXISTING P MANUAL PULL STATION 0 NOTIFIER 640 Horn/Strobe, ceiling mount TO REMAIN) 64"-68" ® r 1 60" 42"-48" .0' Strobe (candela specified) Horn Only ^� ALL HEIGHTS MEASURED FROM FINISHED FLOOR EAST BUILDING STANDARD MOUNTING HEIGHT DETAIL '"ID Weatherproof Horn/St ~ Q robe � OQ (CURRENTLY REPORTS NOT TO SCALE Q� TO SOUTH BLDG FACP) �T� NEW NOTIFIER FACP WILL BE MOUNTING HEIGHT NOTES: -�-� Sprinkler Waterflow Switch O INSTALLED IN SOUTH BLDG 1. MOUNTING HEIGHTS ARE PER NFPA 72 AND ADA ACCESSIBILITY GUIDELINES. UNDER THIS SCOPE OF WORK 2. REMOTE LIGHTS AND REMOTE TEST STATIONS SHALL BE MOUNTED ON THE WALL BELOW ITS ~� ASSOCIATED DEVICE & SHALL BE CLEARLY VISIBLE. Sprinkler Valve Tamper Switch 3. ADDRESSABLE MODULES SHALL BE MOUNTED AS TO BE ACCESSIBLE. 4. WHERE LOW CEILING HEIGHTS DO NOT ALLOW FOR VISUAL OR AUDIBLE/VISUAL DEVICES TO M O O BE INSTALLED AS NOTED, APPLIANCES SHALL BE MOUNTED WITHIN 6" OF THE CEILING. CR Control Relay w l 5. IN ADA UNITS, 11OCD STROBES MUST BE MOUNTED 24" BELOW THE CEILING. 6. MOUNT EXTERIOR HORN/STROBES 10' ABOVE FIRE DEPARTMENT CONNECTION. MM �1 O Single Monitor Module DH //��--11 � � • ^ Door Holder (120V) O Fire/Smoke Damper o SITE PLAN (function noted, 120V) �..� SOUTH BUILDING O? (EXISTING NOTIFIER SB Addressable Smoke Detector w/Sounder Base AFP 400 TO BE REMOVED AND REPLACED WITH NEW NOTIFIER NFS3030 UNDER THIS SCOPE z w o � V SITE PLAN/SCOPE OF WORK NOTES: Q z U O THE EAST BUILDING CURRENTLY REPORTS, THROUGH CONVENTIONAL ZONES, TO THE SOUTH BUILDING NOTIFIER AFP400 FACP. UNDER Q � oZa THIS SCOPE OF WORK, THE AFP400 IN THE SOUTH BUILDING WILL BE REPLACED WITH A NEW NOTIFIER 3030 FACP. THE EAST AND - - SOUTH BUILDINGS WILL CONTINUE TO BE MONITORED BY ONE FACP, BUT WILL DIAL OUT AS SEPARATE RESPONSE POINT TO THE Z FIRE DEPARTMENT MONITORING STATION. J w � z w SEQUENCE OF BUILDING PERMIT 2-23-12 z Q w z z DD PRICING 10-31 -11 m CD z SD PRICING 8-8-11 OPERATIONS : z z z Cn J w O c o w ISSUED FOR: DATE :CD � O U FIRE ALARM WIRE TYPE CHART J C w O Q m p m I- I- -J cn Q m CD Label Description Suggested Wire Type o z M m C/) > cn m g Iz LLJ AC 120VAC Power Wiring 3#12 AWG Solid (w/Ground) Q < O Q m O Q z 0 0 w � (w m cn L Signaling Line Circuit #18 AWG Twisted Pair g O m Q o- z Q LiJ P 24VDC Power Wiring 2#14 AWG Solid- < Q z Cn O (n O 0 J z Q N Notification Appliance (Horn/Strobe) Wiring 2#14 AWG Solid Lli w w f- z z F-- L: w J o w 0 w 0 X Auxiliary Circuit (Relay) Wiring 2#14 AWG Solid Z � Shaner Life Safety DEVICE Q Q W 0 0 z 0 � O z w Q z w � Z Indicating Device Circuit (Zone) Wiring 2#16 AWG Solid DESCRIPTION > > U Q Q z � � � J w -1 O A Annunciator Wiring 2#18 AWG Solid f > < 0 0 Q = O O z — 0- w O PO Box 1073, Frisco, Colorado 80443 0 0 0 ry 0 (n a_ Cn 0 z O D SHANERLS®COMCAST.NET; (970) 409-9082 1. NO T-TAPPING PERMITTED ON ANY CIRCUIT, UNLESS ALLOWED BY MANUFACTURER, 2. WIRING SHALL BE IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS, MANUAL PULL STATIONS X X X X TO NEXT REMOTE POWER SUPPLY SYSTEM SMOKE DETECTORS X X X X I- Y N U �/ �/ �/ THESE DRAWINGS AND SPECIFICATIONS AND THE ELEV LOBBY/SHAFT/EQUIP RM SMOKE X X X X IDEAS, DESIGNS AND ARRANGEMENTS DOGE W REPRESENTED THEREBY ARE AND SHALL REMAIN HOLDER L7 -' RELEASE U U �EOLR PROPERTY OF THE ARCHITECT, AND NO PART DH � z 0 THEREOF SHALL BE COPIED, DISCLOSED TO Z Z ~ (TYP) (TYP) OTHERS, OR USED IN CONNECTION WITH ANY HEAT DETECTORS (ELEV SHAFT, EQUIP RM) X X X X X L (n 0- WORK OR PROJECT FOR WHICH THEY HAVE BEEN M M CR ? 0 U N PREPARED WITHOUT THE WRITTEN CONSENT OF (TYP) (TYP) (TYP) (TYP) (TYP� 0° 0�EOLR THE ARCHITECT. VISUAL CONTACT WITH THESE (TYP) (TYP) DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN WATERFLOW SWITCH X X X X HOLDER N FACP NAC1 DIMENSIONS ON THESE DRAWINGS SHALL HAVE `- -" RELEASE PRECEDENCE OVER SCALED DIMENSIONS. ELEV - ' REMOTE 0�EOLR CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE EAST BLDG FOR ALL DIMENSIONS AND CONDITIONS ON THE FUNCTIONS Z Z " POWER (TYP) (TYP) JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VALVE TAMPER SWITCH X X L FIRE ALARM RT� Ek CR— M M CR F 1 ? TERMINAL SUPPLY VARIATIONS FROM THE DIMENSIONS AND (TYP) (TYP) (TYP) (TYP) (TYP) (TYP) (TYP) (TYP� L CABINET 0�EOLR CONDITIONS SHOWN BY THESE DRAWINGS. ROOM SMOKE DETECTORS X X (TYP) (TYP) L N FACP NAC2 SYNC CIRCUIT AC POWER LOSS X X CONNECTION TO SOUTH BLDG FACP FIRE ALARM COVER SHEET GROUND FAULT X X SYSTEM A PRINTER I NEW OPEN CIRCUIT/SHORT CIRCUIT X X SYSTEM RISER DIAGRAM LCD REMOTE A NOTIFIER ANNUNCIATOR 3030 FACP (LOCATED IN SOUTH BUILDING AT FRONT DESK) NOTE: ELEVATOR RECALL CONSISTS OF PRIMARY AND SECONDARY RECALL. PRIMARY RECALL IS TO THE GROUND FLOOR, SECONDARY IS TO THE 2ND FLOOR. PRIMARY RECALL OCCURS WHEN THE SMOKE DETECTORS IN THE ELEVATOR EQUIPMENT ROOM, DEDICATED 120V SHAFT, OR ELEVATOR LOBBIES EXCEPT GROUND FLOOR ACTIVATE. SECONDARY RECALL TO FACP Ac FA1 . 0 OCCURS WHEN THE SMOKE DETECTORS LOCATED IN THE GROUND FLOOR ELEVATOR LOBBIES ACTIVATE. I~� W w ———— — ————— — — — — — — — — — — — —— ——— — — — — — — — — — — — —— — — —— ——— — OQ 0 ❑1 HELPHENS WHITE O CHANNEL O O SB O SB 003 S13 � 002 � 2 001 0 � ^ MCINTYRE 1 0� OSB �S� SB O O O O G Ll 1)-H I -7 03 0 004 a � v 0 0 0 r-'\\ FO— FO-01 0 0 0 ❑ a o o o0 0 o O E CORRIDCR OC_ ,� Op 005 C O P I�N��Iv�/JII P 0 P (E) KITCHEN (N) STAIR o15 O C OlOA ® CU 0 ��I O c (E) CORRIDOR Op MM R y U (E) MECH. (E) BREAK n. N D R)�== O Z o M ROOM ROOM ROOM P ❑ m T � ° P n M Q O M SF-1 FC-1 v Q a F ( o o Z a DH Q u - M Nz z El ® ® � ❑ O � wZM ® � z0 w U Z Q ti O ° Op O ° ® O ° O O Op P° ° ED El P ® Op O o ° ® ® ° O O O (E) OFFICE P 014 El 1:1 El EN111 � OP ® ° ® ® ° BUILDING PERMIT 2-23-12 ? O ° DD PRICING 10-31 -11 ® SD PRICING 8-8-11 (E) WILDWOOD ❑ ❑ ISSUED FOR: DATE: ROOM NOTES : FLAG NOTES : 013 ® Op O ° O O ° Op 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. O BASES SHALL BE PROVIDED. SMOKE SENSOR NOTIFIER ACCLIMATE DETECTORS WITH SOUNDER ` El ED 2. A NEW FIRE ALARM SYSTEM SHALL BE PROVIDED SHALL ACTIVATE A SUPERVISORY CONDITION AT THROUGHOUT THE BUILDING. REFER TO SYSTEM THE FACP AND SOUND A LOCAL ALARM Shaner Life Safety SPECIFICATIONS FOR DESIGN REQUIREMENTS. THROUGHOUT THE UNIT (TANDEM WIRE O ® ° O — 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND DETECTORS TOGETHER). THE HEAT SENSOR ® ° ® Po Box 1073, Frisco, Colorado 80443 ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE SHALL ACTIVATE GENERAL ALARM IN THE 0 0 0 SHANERLS®COMCAST.NET; (970) 409-9082 ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE BUILDING. SOUNDER BASES PROVIDE GENERAL a a a C LOCATIONS, SYSTEM DESIGN AND INSTALLATION. ALARM SIGNAL IN UNITS. ED � Q 4. RUN FIRE ALARM WIRE IN NEW SOFFITS BUILT FOR 0 0 THE SPRINKLER UPGRADE. SOFFITS ARE NOTED O FIRE ALARM TERMINAL CABINET. FIRE ALARM ® Op O ° ON THIS SHEET. CONTRACTOR SHALL PULL REQUIRED DATA, ® Op ® ° NOTIFICATION AND SLC CIRCUITS FROM THE NEW SOUTH BUILDING FACP. OOVERHEAD DOOR, TO BE CLOSED ON O O THESE DRAWINGS AND SPECIFICATIONS AND THE BASEMENT ALARM OR WATERFLOW IN BUILDING. IDEAS, DESIGNS AND ARRANGEMENTS PROVIDE CONTROL RELAY FOR INTERFACE TO REPRESENTED THEREBY ARE AND SHALL REMAIN FIRE ALARM SYSTEM. PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE BASEMENT FLOOR PLAN FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND SCALE: 1/89$ = 11-099 CONDITIONS SHOWN BY THESE DRAWINGS. BASEMENT FIRE ALARM PLAN FA2 . 0 O I~� w O w �ll rr O V STAIR E 0 0 M--� w � Qr W O ❑ c STAIR F ❑ ❑ — w 106 110 v 1 ❑ ❑ ❑ � � 00 20 � O ❑ ❑ ❑ — J SIB SB OSB TOMPKINS HUZELLA �/1 ►� 103 w 101 O MCINTYRE D 105 O q LJ o 0 m 0 0 D1Q0 0 L7 0 O O2 O O2 O 2 O 4SB ? SB O SB SB SB 00 O SB r-L 0 0 0 0 0 O z z a C-HAN MITNICK OLTHOF BERMUDE, - C ° 113 111 109 107 O 0 0 C C w w ~ ° M O p STAI R H Q OO Q w 114 ORRIDg o Y C N J a O O O Q SB OSB 7�SB OSB 0 0 0 2 0 2 u w w Z SB SB SB SB Q o o o o Q 0 a Q o 0 2 O 7 O w u Z J 0 4' 0 0 0 O O CORRIDOR Q SB SB �� �� 00 0 c� 00 ,00 OP 0 0 OP Q ❑D 0 0 0 0 2 STAIR ELEV. SB O SB ,04A 20 20 O 20 O 10 0 CHAN YEE OsB 0sB OsB �sB O2 O2 1 117 115 ORRIDO OSB OSB ORRIDO SB SB - OP 112 108 0 STAIR C 0 -)'TAIR B j 0 C OP 112A 108A CR(4) Ad LA�6SB 0S6 ELEV. EL ELO MACH RM BUILDING PERMIT 2-23-12 a 0 0 a 0 ,1 P to C 1048 / DD PRICING 10-31 -11 4 0 SD PRICING 8-8-11 C 0� P 2 P WP ISSUED FOR: DATE: OOP ELEV. OP OO P MACH. RM ® ELEV. J-4, ;' ,126 (4)CR MACH. RM CR (4) (`3 1086 O 2 2 Shaner Life Safety @ 0 O O - - Engineering 0 2 SB SB PO Box 1073, Frisco, Colorado 80443 2 2 (-ORRIDOF SB SB SHANERLS®COMCAST.NET, (970) 409-9082 116 STAIR D 0 0 1 11bA 0 o ELEV. � THESE DRAWINGS AND SPECIFICATIONS AND THE P C, ,,,, IDEAS, DESIGNS AND ARRANGEMENTS 1 S T FLOOR PLAN REPRESENTED THEREBY ARE AND SHALL REMAIN �U PROPERTY OF THE ARCHITECT, AND NO PART J P OTHERS,THEREOF SHALL BE COPIED, DISCLOSED TO SCALE: �H�� _ —O" / OTHERS, OR USED IN CONNECTION WITH ANY FLAG N 0 T E S . WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT❑ 0 P NOTES : THE ARCHITECT. V SUALE CWRITTEN ONTACT WI HS THESE ELEV. DRAWINGS OR SPECIFICATIONS SHALL MACH. RM z ® 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. 01 EXISTING FIRE ALARM ANNUNCIATOR TO BE CONSTITUTE CONCLUSIVE EVIDENCE OF REPLACED. ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN 1166 g(4) 2. A NEW FIRE ALARM SYSTEM SHALL BE PROVIDED DIMENSIONS ON THESE DRAWINGS SHALL HAVE �3 THROUGHOUT THE BUILDING. REFER TO SYSTEM �2 NOTIFIER ACCLIMATE DETECTORS WITH SOUNDER PRECEDENCE OVER SCALED DIMENSIONS. SPECIFICATIONS FOR DESIGN REQUIREMENTS. BASES SHALL BE PROVIDED. SMOKE SENSOR CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE SHALL ACTIVATE A SUPERVISORY CONDITION AT FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY THE FACP AND SOUND A LOCAL ALARM 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND VARIATIONS FROM THE DIMENSIONS AND ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE THROUGHOUT THE UNIT (TANDEM WIRE CONDITIONS SHOWN BY THESE DRAWINGS. ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE DETECTORS TOGETHER). THE HEAT SENSOR LOCATIONS, SYSTEM DESIGN AND INSTALLATION. SHALL ACTIVATE GENERAL ALARM IN THE BUILDING. SOUNDER BASES PROVIDE GENERAL 4. RUN FIRE ALARM WIRE IN NEW SOFFITS BUILT FOR ALARM SIGNAL IN UNITS. THE SPRINKLER UPGRADE. SOFFITS ARE NOTED ON THIS SHEET. O PROVIDE ELEVATOR RECALL AND POWER SHUNT FOR NEW ELEVATOR. I ST FLOOR OMONITOR SPRINKLER WATER FLOW/TAM PER FIRE ALARM PLAN SWITCH. OPROVIDE OUTSIDE HORN/STROBE ABOVE FIRE DEPT CONNECTION. COORDINATE WITH SPRINKLER CONTRACTOR. FA2 . 1 O W W STAIR E ❑ ❑ 'y V / STAIR G STAIR F ~� 210 206 ❑ ❑ ❑ o ❑ ❑ LH o ❑ ❑ � �/ 0 0 :III, ip ❑ ❑ ❑ O O ° O ❑ ❑ ❑ OSB OSB SB Q ❑ I AIF WOODSMALL r� LE 100 C STERLING 0 0 0 O 0 0 C'I 205 0 O h—I .B. E.B. O E.P E B. '..P. E.P O O O 1 °s6 O o s6 O STAIR H OSB OSg s6 o a o o Q � � o 0 - O 'D 0 O LARNED RAUCH RAUCH RAWSON O O O w W m ❑ 0 0 213 211 100 0 (D 209 207 J 0 a o a D 0 N o 13 00 00 00 � 0 w J V m \ ® x O O C� U m ¢ w O O O o ❑ ❑ ❑ ❑ O ? N a V 2 SB 1 OS SB O OSB OP Q °_ Z O O O O wKZN o 0 � ' O l� Q o 0 o Q ��,' ° \ O o ° O � Q.. O J w Z o 0 O 0 2 J O °SB °SB OSB OSB SB SB Q �O OO DO C� OD CORRIDOR O 0 Op Q 204 F p - I - — - — � o E.B. E.B O O OSB OSB 0 0 O O ELEV. OO OSB OSB O ° O° ? 2 44C C UNIT DE UGARTL OSB IDO SB SB ORRIDO OSB OSB CEO � OO 217 215 0000 .212 208 O °p STAIR A MAI DS C LOS. Op 204A 76 O O ° 204B SB SB s' ELEV. ELEV. 0 0 0 212c 2osc nom_ _ — BUILDING PERMIT 2-23-12 O 0 C � % DD PRICING 10-31 -11 �� 2 Ou OP Op STAIR TOWER A sD PRICING 8-8-1 1 OP LQ-1 MAIDS MAIDS � � ISSUED FOR: DATE. cL F STAIRC CL NOTES . FLAG NOTES . - - - IDO 21 AIR p F STAIR B 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. O NOTIFIER ACCLIMATE DETECTORS WITH SOUNDER 2088 08 BASES SHALL BE PROVIDED. SMOKE 16 2. ANEW FIRE ALARM SYSTEM SHALL BE PROVIDED DETECTOR SHALL ACTIVATE A SUPERVISORY THROUGHOUT THE BUILDING. REFER TO SYSTEM CONDITION AT THE FACP AND SOUND A LOCAL O SPECIFICATIONS FOR DESIGN REQUIREMENTS. ALARM THROUGHOUT THE UNIT (TANDEM WIRE 01 01 (D 3. TOGETHER). THE HEAT SENSOR Shaner Life Safety 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND SHALL ACTIVATE GENERAL ALARM IN THE O O O O ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE BUILDING. SOUNDER BASES PROVIDE GENERAL - - ring SB SB SB SB ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE ALARM SIGNAL IN THE UNIT PO Box 1073, Frisco, Colorado•80443 . LOCATIONS, SYSTEM DESIGN AND INSTALLATION. SHANERLS®COMCAST.NET; (970) 409-9082 0 0 � 0 STAIR TOWER C STAIR TOWER B 4 THE SPRINKLER UPGRADE. N 0 FIITS TARE NIOTED R O SWITCH. SPRINKLER WATER FLOW/TAM PER / ON THIS SHEET. i O O ELEV. 21 bC �( 'I THESE DRAWINGS AND SPECIFICATIONS AND THE �I���I IDEAS, DESIGNS AND ARRANGEMENTS OREPRESENTED THEREBY ARE AND SHALL REMAIN p PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL❑ ❑ BE COPIED, STAIR D OTHERS, OR USED N CONNECTION DISCLOSED WITH ANY MAIDS 21 bA WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF CL THE ARCHITECT. VISUAL CONTACT WITH THESE 216 P CONSTITUTE I OCONCLUSIVIEICATEVIDENCESHAOF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. STAIR TOWER D 2ND FLOOR PLAN SCALE: 1/8" = 1'-0" 2ND FLOOR FIRE ALARM PLAN FA2 . 2 0 w 0 STAIR E 302 � ►� rTl awl O V STAIR G — u 0 0 0 0 POLSTON ELY S AIR F a 307 O C 301 AA O O 308 O JO O 0 (D 00o F_ � (D ul w/D O g O SB 4— wio O ❑ O SCHULTE ,� s - STAIR H AUTENREITH BROWNING OLTHOF 310 a o Q Q o 0 0 319 316 313 (LOCKED) Q W X22 0 2 0 T_ __T. F'o 7 J 00 c o0 Do O O O 0 0 a o o o �00 2 p 00 0o Oo 00 C 1 � O " M w 2 m OSB SB wio wiD SB SB wio C P w o ° I� Fe �� ORRID( Ose OSB OSB OSB Q w /�\ O (�1\ O O O O O O /�\ O O o F Z ° M 1\�/// \\�// I O M 0 0 OSB OSB Sob CORRIDOR u Q DO C 2 O a0 � c 2 � O Q � oza U M z � D P p w K Z w ELEV. - 1 O O O O O 2 O ? O 306C �- II URSANER FARCUS OO S13 O2 SB ' SB (D SB OSB 0 S OSB OSB O 325 324 D P :1 ED O O 000— _ _ _ _0 0 0 0 ' 00 STAIR 2 p 306A w/o SB O OSB wD - ° ° MAIDS ELEV. ELEV. CLOS. O o � o O o 0 C 2 (D Op ao � a0 O MAIDS MAIDS OP CLO STAIR C CL S. STAIR B BUILDING PERMIT 2-23-12 3186 318A 3 312A DD PRICING 10-31 -11 SD PRICING 8-8-11 ISSUED FOR: DATE: O O O P - O O O — - SB SB SB SB NOTES : FLAG NOTES : 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. O NOTIFIER ACCLIMATE DETECTORS WITH SOUNDER j 0 0 BASES SHALL BE PROVIDED. SMOKE 2. A NEW FIRE ALARM SYSTEM SHALL BE PROVIDED DETECTOR SHALL ACTIVATE A SUPERVISORY i Shaner Life Safety THROUGHOUT THE BUILDING. REFER TO SYSTEM CONDITION AT THE FACP AND SOUND A LOCAL _ _ _ _ ring SPECIFICATIONS FOR DESIGN REQUIREMENTS. ALARM THROUGHOUT THE UNIT (TANDEM WIRE PO Box 1073, Frisco, Colorado 80443 ° 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND DETECTORS TOGETHER). THE HEAT SENSOR SHANERLS®COMCAST.NET, (970) 409-9082 ELEV. SHALL ACTIVATE GENERAL ALARM IN THE ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE BUILDING. SOUNDER BASES PROVIDE GENERAL 326C ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE ALARM SIGNAL IN THE UNIT. LOCATIONS, SYSTEM DESIGN AND INSTALLATION. 4. RUN FIRE ALARM WIRE IN NEW SOFFITS BUILT FOR OMONITOR SPRINKLER WATER FLOW/TAM PER P THE SPRINKLER UPGRADE. SOFFITS ARE NOTED SWITCH. ON THIS SHEET. MAI DS CLOS. STAIR D THESE DRAWINGS AND SPECIFICATIONS AND THE 326A REPRESENTED E DESIGNS THEREBY A EDAND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. 3RD FLOOR PLAN 3RD FLOOR SCALE: 1/8" = V-0" FIRE ALARM PLAN FA2 . 3 4 O I~� W W a�wll o V •D.S. • D.S. • D.S. • D.S. I Ds, D.S. O I I OLSTON I I s� I I ELY I a I I I I 1 O 407 401 1 D.S.• Il'I 11.4 I I I 1 l ON UP I--i D.S. L I — — — _D� L�. — — — — — — _ _D.S.• • O OSB AUTENREITH BROWNING SCHULTF O 1 S O a a 419 OSB 416 O O OLTHOF 410 O 1 I �1 SB SB 413 0 o O 2 O Q Q O 0 I I O I I � se � � 1 se ,. I � � M w O 0 N D.S. w z m H \J 0 � o OSB Q w o M 1 o � wx o ? SB O2 SB o O 1 0 1 w Z � .D.S.• 1 (D F w Z M 1 ° ° ° ° I I ❑ ° I w � a ° Q _ d � I I I I URSANFR FARCUS 1 _ _ _ 425 OSB OSB 424 I I I 1 i D.S. I I �1 ❑ ❑ 1 ❑ ❑ ❑ 1 •D.S I D.S. IL - - - - - - - - - - - � � - - - - - - - - - - —1 L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � 1 j0SEI :� OSB 1 0 O - - - - - - - - - - - - - - - - - - - - - - - SB .D.S. • o 1 a - I O � I I 0 O < j,— O BUILDING PERMIT 2-23-12 1 DD PRICING 10-31 -11 I I I 1 1 SD PRICING 8-8-11 NOTES : ISSUED FOR: DATE: 1 1 FLAG NOTES : OSB 1 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. O TYPICAL UNIT FIRE ALARM LAYOUT. NOTIFIER O 2. A NEW FIRE ALARM SYSTEM SHALL BE PROVIDED ACCLIMATE DETECTORS WITH SOUNDER BASES THROUGHOUT THE BUILDING. REFER TO SYSTEM SHALL BE PROVIDED. SMOKE DETECTOR SPECIFICATIONS FOR DESIGN REQUIREMENTS. SHALL ACTIVATE A SUPERVISORY CONDITION AT THE FACP AND SOUND A LOCAL ALARM 3. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND THROUGHOUT THE UNIT (TANDEM WIRE F I ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE DETECTORS TOGETHER). THE HEAT SENSOR Shaner Life Safety 1 ° ° 01 ° I ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE SHALL ACTIVATE GENERAL ALARM IN THE _ I I J LOCATIONS, SYSTEM DESIGN AND INSTALLATION. BUILDING. SOUNDER HBASES UNIT.PROVIDE GENERAL PO Box 1073, Frisco, Colorado SHANERLS®COMCAST.NET; (970) 409-909-90 82 4. RUN FIRE ALARM WIRE IN NEW SOFFITS BUILT FOR THE SPRINKLER UPGRADE. SOFFITS ARE NOTED — — -1 ON THIS SHEET. O SPRINKLER FEED TO ATTIC DRY PIPE SYSTEM. MONITOR WATERFLOW, TAMPER AND LOW Al SWITCH. FIELD COORDINATE EXACT LOCATION •D.S. WITH FIRE PROTECTION CONTRACTOR. THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE •°'S' • DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. 4TH FLOOR PLAN 4TH FLOOR FIRE ALARM PLAN SCALE: 1/8" = 1'-0" FA2 . 4