Loading...
HomeMy WebLinkAboutB12-0044NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES j� I �owuaF���, Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0044 Job Address: 1635 GOLF TERRACE VAIL Location......: GOLF COURSE TOWNHOMES UNIT H-27 �'� Parcel No....: 210109104027 �WNER �GOWEN, JOHN HOWERTON & SUSAN 03/14/2012 840 STEELE DEN'1/ER CO �0209 4PPLICANT GOWEN, JOHN HOWERTON & SUSAN 03/14/2012 840 S STEELE DENV1ER CO �30209 �ONTRAC OR THD COLORADO 03/14/2012 Phone: 970-376-0008 PO �OX 8338 AVON CO 81620 License: C000003250 �escription: �EBUILD STAIRS AND RAILINGS. REMOVE SEVERAL WALLS IN AND 4ROUND KITCHEN. ADD NEW STRUCTURE FOR SUPPORT. CREATE NEW 41TCHEN A�ID WETBAR, UPGRADE FIREPLACE AND ADD THIN STONE �UT VENEER. RELOCATE WASHER AND DRYER. Occ pancy: R-2 Type Construction: VA Project #: Applied.....: Issued... PRJ 12-0077 03/14/2012 � � 'L 7� 'i '�-. Valuation: $58,575.00 .<,.....=x.. ,..,....>.>,..�.........,,,.,�....,>.>.�..,,.,,..>..,...<.x,�<.,.,,,.. FEE SUMMARY ..<.........�,�.<......_.>�.......,.>x.�...,,,._...�.....,,x............�...,.�,. . .. 3uilding Pe mit -----------> $706.75 Bldg Plan Check ----------> $459.39 Use Tax Fee-----------------------> $971.50 =lectrical Permit ---------> $115.00 Elec Plan Check -----------> $74.75 Restuarant Plan Review--------> $0.00 Vlechanical ,�Permit ------> $120.00 Mech Plan Check ---------> $30.00 Additional Fees--------------------> $0.00 �lumbing Permit --------> $90.00 Pimb Plan Check ---------> $22.50 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 TOTAL PERMIT FEES--------------> $2,609.89 Payments-------------------------------> $2,609.89 BALANCE DUE------------------------> $0.00 DECLARATIONS I hereby acl�nowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that ali the information as required iis correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable t�ereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - i:00 PM. �. -, -- r -_ :� -�rJ- � 1.,� Sig at of Owner or Contractor Date � ` � F: Ua :� c; � w a�;� Print Name combination permit_012811 *�***��xttzte�tf��t���t+:xxzxx��<ttr�x�t�+xtxx��*wer�:x��xx�sxx�+�:xxxz�w�r���r�+t.�r��w�r:��+�x�+x���xwre����+xx��::wrw:�xarfti.x:<+xwrx�+.zta:+����xexe�awx:fxx,rs.f�rezrw��x�x.x+�.x:x�+ CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B12-0044 Address: 1635 GOLF TERRACE VAIL Owner: GOWEN, JOHN HOWERTON & SUSAN TOLLESON Location: GOLF COURSE TOWNHOMES UNIT H-27 �,....,,..�<.�;,�,<,,,,........<,�..,, ............................................<....�..,,.,,,.,.....,.,.<.,«,..,.....�..,..,,,....,>�.><..,,,<.,,,<,,..,><>,......�,.«.>.,..,..��... Cond: CON0012463 upgrade to monitored fire alarm system/co detection combination permit_012811 �ow� �F v� � k * * �F * �k Yr t * ir * �F �F Ye * �k rt * * 4 * * * * i� * ir ie * * * * * * * * * * * * * * * * aF �k �k * * * * �F * * * * * # a4 a4 * * i # * * * �e * *+F +k � e �t * * �/r * * * * * * * Yr * * M * }� * Yr * ir ie �k �k i r * * * * * * Y' * * * � H 4 �k * * * *! r * rt i r i r i� 1r at �t f ak +t ie +t 4 i� lr * * * * *Y� * �k �k * * * ir ir i� * * REQUIRED INSPECTIONS AND STATUSES Permit #: B12-0044 Address: 1635 GOLF TERRACE VAIL Owner: GOWEN, JOHN HOWERTON & SUSAN TOLLESON Location: GOLF COURSE TOWNHOMES UNIT H-27 k * * * � 4 * * * * * * *Y� * * * * * * * * ic � k t ak * t t * * * * * * eF * eF �R ir �k ak * * * �k * * * * �k �F * * * * �k * �k * * * * * * * * * * * * * * * * * * * * * * * �l r ie �k �F t ir * k * * * * *YeYe ie # rYr �rYe �k t � k aF �* * aF Y� Yr * * * * �k �F * * �e+k aF+F+k * �F Yr �t �F rt i I t!e * * * �.t �F aF �k * * * * * * * rt * * � 4 Item: 00120 ELEC-Rough Item: 00200 MECH-Rough item: 00220 PLMB-Rough/D.W.V. tem: 00230 PLMB-Rough/Water tem: 00240 PLMB-Gas Piping tem: 00030 BLDG-Framing tem: 00050 BLDG-Insulation tem: 00060 BLDG-Sheetrock Nail tem: 00190 ELEC-Final tem: 00290 PLMB-Final tem: 00390 MECH-Final tem: 00090 BLDG-Final combination permit_012811 0 • ^ �".<:�. : raw�u a� upf� � � Department of Community Development � 75 South Frontage Road � Vail, CO 81657 Tel: 970 479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: �,,, I b 35 (301 �� lerr�� Z� (Number) (Street) (Suite #) Building/Complex Name:l(�J''� ��f �����%��'��� Project #: ��iL j � �� ' . - : • �y:� Building Permit #: l7 �� � ��y � Contractor Information I Lot #: Block # Subdivision: �'�"� CJ�rct� Iv� L _____ _____ _ _ _ _ _. Business Name: � D�/a Q^ Work Class: New ( ) Addition ( ) Alteration (� ) Business Address: Q4 �j l�� p J (� _! City ��i� � State: �c'� Zip: (� �b LV Type of Building: �� i 1 Single-Family ( ) Duplex ( ) Multi-Famil (�) Contact Name: � re�� � h� �iL � -�--vcv i1�Qvv�L° Commercial ( ) Other ( ) Contact Phone: �� l� � 1 C� ' � ��� L,^� ,���L`� Work Type: Interior (�[ ) Exterior () Both () Contact E-Mai�'1 • �C..��f C►� r` (� �.10.�� o �� �� __ _ _ ` Owner/Owner's Representative Signature (Required) Applicant Information j � ��� � ��sa� C� o u�,� Applicant Name: v Applicant Phone: �/ 7 Z�� 3`� ����� ` b Applicant E-MaiL � w O W J\ � F�I I, �L�1� Project Information�` /'� Owner Name: .� JV�v� (�U wN � Parcel #: 2 � � I " C�� �� �� -' ��-� (For Parcel #, contact Eagle County Assessors Office at (970-328-8640 or visit www.eag I ecounty. uslpatie) Detailed Scope and Location of Woric: `� ^ . , � . ► , �t (use additional sheet if necessary) For Office Use Only: Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Valuation of Woric Included Plans Included Work =lectrical ( )Yes ( )No ( )Yes ( )No `1 G� Vlechanical ( )Yes ( )No ( )Yes ( )No � 'lumbing ( )Yes ( )No ( )Yes ( )No �%�5 3uilding ( )Yes ( )No ( )Yes ( )No �'�� Value of all work being performed: $ � V� ` 7 (value based on IBC Section 109.3 & IRC Section 108.3� � � Electrical Square Footage Date Received: '� ��� � MAR 0 9 2011 � '� O1-Jan-11 ■ onsu ln Asbestos Inspection and Sampling Report 1365 Golf Terr, Unit 27, Vail, Colorado 81657 Presented To: Mr. Trent Hubbard THD Colorado PO Box 8338 Avon, CO 81620 Performed & Prepared By: Mr. Steve Shurtliff DS Consulting, Inc. PO Box 6864 Avon,CO 81620 (303) 378-1544 Project Details: Project Number: 5504 Conducted: March 6, 2012 TABLE OF CONTENTS PROJECT OVERVIEW 1.0 Introduction 2.0 Scope of Work 3.0 Site Description 4.0 Certifications 5.0 Inspection, Sampling & Analytical Procedures 5.1 Inspection Procedures 5.2 Sampling Procedures 5.3 Analytical Procedures 6.0 Homogeneous Areas 6.1 Material Friability 6.2 Material Classifications 6.3 Material Conditions 6.4 Sample Quantities 7.0 Overview of Findings 8.0 Conclusion & Recommendations 9.0 Asbestos Abatement & Demolition Requirements 10.0 Major Asbestos Spill Response 11.0 Disclaimer & Limitations APPENDIX A Inspector & Firm Asbestos Certificates APPENDIX B Analytical Data 2 PROJECT OVERVIEW 1.0 Introduction On March 6, 2012, Mr. Steve Shurtliff with DS Consulting, Inc. (DSC) conducted a limited asbestos inspection and collected asbestos bulk-samples of suspect asbestos-containing materials (ACM) within a portion of the single-family residence located at 1365 Golf Terr, Unit 27, Vail, Colorado. The purpose of the limited inspection was to identify and sample potentially hazardous friable and non- friable ACM that may be impacted by upcoming remodeling activities. 2.0 Scope of Work The scope of the limited inspection and bulk-sampling was limited to specific areas of the residence defined by the construction company that are to be impacted by the remodel. These areas included multiple walls within the bottom and main levels. The remaining areas within the residence, garage or any out-building on the property were not included in the scope of the inspection. The limited asbestos inspection did not constitute a full building inspection and does not fulfill the asbestos inspection requirements for structures that are to be demolished. 3.0 Site Description The residence is a wood-framed, three-level, single-family residence with an attached garage. 4.0 Certifications The limited asbestos inspection and bulk-sampling was conducted by Mr. Steve Shurtliff with DSC. DSC is a Colorado Department of Public Health and Environment (CDPHE) certified Asbestos Consulting Firm, Registration No. 14912. Mr. Shurtliff is a CDPHE certified Building Inspector; having certification number 15413 (see AppendixA for certificates). 5.0 Inspection, Sampling & Analytical Procedures 5.1 Inspection Procedures The limited asbestos inspection was conducted by an Environmental Protection Agency (EPA) and CDPHE certified Building Inspector. The inspection procedures included identifying and sampling suspect ACM within the pre-defined areas, submitting samples to an accredited laboratory for analysis, classifying the materials and assessing their condition, and compiling a final report detailing the inspection and the analytical results of the bulk-samples. 5.2 Sampling Procedures Statistically random bulk-samples representative of the suspect ACM of each homogeneous area were collected according to the guidelines published as EPA Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763 and CDPHE Regulation Number 8, Part B- Asbestos (Reg. 8). DSC has collected the appropriate number of bulk-samples to meet all regulatory requirements for the classification and quantity of each homogeneous area. Some minor destructive sampling was Kj conducted; however, walis, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Materials containing less than 1% asbestos are not regulated by CDPHE Regulation 8, Part B- Asbestos. However, all demolition/abatement activities should be performed following the applicable Occupational Safery and Health Administration (OSHA) regulations. This would include, but not limited to, the appropriate asbestos training for the rype of material being removed/disturbed as well as having a properly trained supervisor onsite, using wet removal methods, wearing adequate personal protective equipment (HEPA-filtered particulate respirators), medical surveillance of workers, personal-exposure air monitoring, area air monitoring in occupied buildings, etc. There may also be landfill disposal requirements for these materials, depending on the facility. DSC recommends that all demolition/renovation areas involving any amount of asbestos be subjected to visual inspections and a final clearance air testing by a CDPHE-certified Air Monitoring Specialist (AMS) after the work has been completed, but before any containments are dismantled and the area is reoccupied. 5.3 Analytical Procedures All asbestos bulk-samples were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory via Polarized Light Microscopy (PLM) for asbestos content (see Appendix B for laboratory report). The percentage of asbestos within each individual bulk-sample can vary depending on sample location, homogeneity of the material, and the type of application. Any sample reporting a"TRACE" amount of asbestos must be considered positive for asbestos greater than 1% unless it is re-analyzed utilizing the point-count method and verified to be less than 1%. 6.0 Homogeneous Areas A Homogeneous Area (HA) includes materials that are uniform in appearance, color, texture and date of application. The asbestos content of the bulk-samples collected within a homogeneous area can be applied to the entire homogenous area if they conform to the above characteristics and the regulated minimum sample quantities of each type of material are collected and analyzed. 6.1 Material Friability A material can either be friable or non friable. A friable material is one that, when dry, can be pulverized, or reduced to powder by hand pressure, a non-friable material cannot. A non-friable material may become friable if its condition had deteriorated or has been impacted by forces that have rendered it friable. 6.2 Material Classifications Sampled materials are divided into one of the following three categories: • Surfacing Material: sprayed or troweled onto structural building members • Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation • Miscellaneous Materiat: all other materials not classified in the above two categories 6.3 Material Conditions Sampled materials are placed into one of the three following categories of conditions: 4 • Good: none to very little visible damage or deterioration • Damaged: the surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed, or one-quarter if the damage is localized • Significantly Damaged: the surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over greater than one-tenth of the surface if the damage is evenly distributed, or one-quarter if the damage is localized 6.4 Sample Quantities DSC collected at least the minimum number of samples from each homogeneous area necessary to meet all regulatory requirements for the quantity of material to be disturbed. The quantities listed in this report are approximate and on-site verification of the exact quantity of each material is required. The following outlines the minimum sample quantities required per homogeneous area: • Surfacing Materials: up to 1,000 ft2 of material requires a minimum of three (3) samples; between 1,000 ftz and 5,000 ftz of material requires a minimum of five (5) samples; over 5,000 ftz of material requires a minimum of seven (7) samples; one (1) sample of each patch • Thermal System Insulation (TSI): each homogeneous area requires a minimum of three (3) samples; at least one (1) sample must be collected from each patch; and collect enough samples sufficient to adequately assess the material and determine the asbestos content for TSI fittings such as pipe elbows or T's. • Miscellaneous Materials: collect enough samples sufficient to determine the asbestos content 7.0 Overview of Findings Asbestos was not reported within any of the bulk-samples collected and analyzed. DSC collected a total of six (6) asbestos bulk-samples of two (2) homogeneous areas. Table 1 below describes the materials composing each homogeneous area as well as the locations of each bulk-sample collected. Also listed is the classification, condition, friability and estimated quantity of material to be removed and/or disturbed, as well as the asbestos content within each bulk-sample. Please see Appendix B: Analytical Data for the layer break-down of each bulk-sample. 5 TABLE 1 HA Sample Material Sample Material Material Estimated Material Asbestos # ID Description Location Classification Condition Quantity Friability Content SM1-1 Beige/Tan, Stompbrush Bottom Level Entry Wall SM G �600 ftz Friable ND Drywall Texture 1 SM1-2 Beige/Tan, Stompbrush Bottom Level Stairwell Wall SM G �600 ft2 Friable ND Drywall Texture SM1-3 Beige/Tan, Stompbrush gottom Level Hallway Wall SM G �600 ftz Friable ND Drywall Texture SM2-1 Beige/Tan, Smooth Drywall Main Level Laundry Room SM G �100 ftz Friable ND Texture Wall 2 SM2-2 Beige/Tan, Smooth Drywall Main Level Laundry Room SM G �100 ftz Friable ND Texture Wall SM2-3 Beige jTan, Smooth Drywall Main Level Laundry Room SM G �100 ftz Friable ND Texture Wall HA - Homogeneous Area ND - None-detect TR - Trace, <1% Visual Estimate G - Good D - Damaged SD - Significantly Damaged CHRY - Chrysotile ACT - Actinolite SM - Surfacing Material MM - Miscellaneous Material TSI - Thermal System Insulation 8.0 Conclusion & Recommendations ACM was not identified within the areas of the residence that were within the scope of the limited inspection and bulk-sampling performed on March 6, 2012; therefore, no professional abatement activities are required to remove or disturb the above-referenced sampled materials. 9.0 Asbestos Abatement & Demolition Requirements If ACM is to be removed or disturbed in a single-family residence, and the total quantity exceeds any of the regulatory trigger levels of 50 linear ft. on pipes, 32 ft2 on other surfaces, or the volume equivalent of a 55-gallon drum, a CDPHE-certified General Abatement Contractor (GAC) is required to perform the work. The regulatory trigger levels within a commercial building are 260 linear ft. on pipes, 160 ftz on other surfaces, or the volume equivalent of a 55-gallon drum. In addition, formal notification to CDPHE prior to the abatement of ACM as well as air monitoring, visual inspections, and final air clearances by a CDPHE-certified Asbestos AMS is required. DSC can provide the client or building owner with a proposal for project design, abatement oversight and air monitoring upon request. CDPHE regulations allow for the demolition of a building that contains non-friable asbestos-containing materials, such as caulking, mastic or resilient floor tiles. However, demolition must be completed without causing the non-friable ACM to be rendered friable. Burning a building with any ACM is prohibited. Operations such as sanding, cutting, crushing, grinding, pneumatic jacking, etc. of ACM are not permitted. Recycling of building materials such as concrete, metal, or wood that are bonded or contaminated with ACM, e.g. glue, caulking, or mastic is also prohibited. If any of the non-friable asbestos containing materials are to be recycled and rendered friable after demolition (i.e. crushing mastic-coated concrete), these materials must be abated of all ACM prior to shipping offsite for recycling. OSHA regulations regarding occupational exposure during demolition activities is still mandatory. OSHA 29 CFR 1926.1101 requires that workers performing construction-related activities be protected from asbestos fibers in excess of the permissible exposure limit of 0.1 f/cc of air. Contractors are must comply with applicable provisions of OSHA 29 CFR 1926.1101 during demolition and renovation activities. These OSHA provisions include, but are not limited to, PPE and respirators, personnel training, personal- exposure air monitoring, employee medical surveillance, wet removal methods, signage for regulated areas, etc. 10.0 Major Asbestos Spill Response If ACM is significantly damaged and the total quantity exceeds the regulatory trigger levels, the area is deemed a"Major Asbestos Spill." The area is consequently subject to the requirements in Reg. 8, Section III.T.1. - Major Asbestos Spills, as outlined below. Additional asbestos air or dust sampling should also be conducted within the remaining areas not directly impacted by the Major Asbestos Spill to determine if asbestos-containing dust/debris has spread to adjacent areas. If asbestos fibers are found within any other areas or on building contents, they should be included in the scope of professional abatement and decontamination. The following response actions must be followed per Colorado Reg. 8 when a Major Asbestos Spill occurs: • Restrict access to the area and post warning signs to prevent entry to the area by persons other than those necessary to respond to the incident. • Shut off or temporarily modify the air handling system to prevent the distribution of asbestos fibers to other areas. • Immediately contact the Division by telephone, submit a notification in compliance with subsection III.E. (Notifications) and, if in an area of public access, apply for a permit in accordance with subsection III.G. (Permits). • Be exempted from the requirements to have a certified Supervisor on-site at all times, until such time as the immediate danger has passed. Any cleanup or asbestos abatement that must occur after the immediate danger has passed shall be supervised by a person certified by the Division. • Using certified Supervisors and certified Workers in accordance with section II. (Certification Requirements) of this Regulation, seal all openings between the contaminated and uncontaminated areas and establish none-detect air pressure within the contaminated area in accordance with paragraph III.J. (Air Cleaning and None-detect Pressure Requirements). This is to be accomplished using polyethylene sheeting to cover areas such as doorways, windows, elevator openings, corridor entrances, grills, drains, grates, diffusers and skylights. • HEPA vacuum or steam clean all carpets, drapes, upholstery, and other non-clothing fabrics in the contaminated area, or discard these materials. • Launder or discard contaminated clothing in accordance with subsection III.R. (Waste Handling). • HEPA vacuum or wet clean all surfaces in the contaminated area. • Discard all materials in accordance with subsection III.R. (Waste Handling). • Following completion of subparagraph III.T.1.a. through III.T.1.i. above, comply with air monitoring requirements as described in subsection III.P. (Clearing Abatement Projects); air samples shall be collected aggressively as described in 40 C.F.R. Part 763, Appendix A to Subpart E(EPA 1995), except that the air stream of the leaf blower shall not be directed at any friable ACM that remains in the area and • Comply with any other measures deemed necessary by the Division to protect public health. 11.0 Disclaimer & Limitations The activities outlined in this report were conducted in a manner consistent with a level of care and expertise exercised by members of the environmental consulting and industrial hygiene profession. All activities were performed in accordance with all applicable federal, state, and local regulations as well as generally accepted standards and professional practice. No warranty is either expressed or implied. DSC assumes no responsibility or liability for error in public information utilized, statements from sources other than DSC, or developments resulting from situations outside the scope of this project. The details provided within this report outline the inspection activities on the date(s) indicated and should not be relied upon to represent conditions at a later date, the limited number of bulk-samples collected, and the laboratory results of those bulk-samples. The laboratory results contained in this report apply specifically to the materials in which bulk-samples were collected. The results do not include or apply to any other materials within the structure that were not sampled, but may contain asbestos; including materials that may be hidden or inaccessible. Additional inspection and bulk- sampling activities would be required to determine if any other materials contain asbestos. This report has been prepared on behalf of and exclusively for use by the Client, with specific application to their project as discussed in the scope of work. The results of any surfacing material indicated in this report also includes any associated overspray of that material, e.g., under carpet, above suspended ceilings, etc. The information contained in this report is intended as supplementary material for abatement design and is not to be used as the scope of work for abatement activities, bidding or billing purposes. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. DSC can provide a full scope of work for : abatement upon request. DSC does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. E APPENDIXA INSPECTOR & FIRM ASBESTOS CERTIFICATES 10 STATE OF COLORADO ASBESTOS CERTTFIG�TiON* C'olorodo lkpannxm ui Publi..• Hralth anJ F.m�ronmrnt 1ir Polluti� Conixol Div�sion ll��s certifics that Steve Shurtliff cerNficacbo No: �5�t�3 has met the requircments oi25•?-507, C.R.S. and .Air Qualip Control ('ommission Regutation No. 8, Part B, mxi is herebr' certified hy ttte ctatc of ('oloradu in thc follow�ing dfscipfine' Buildin� Inspector* b,cued: nl121:011 Expirrs uo: N12l2012 - �( ; , `_ �yr�{.[,-�C � ��„�.,� � ' liu � f vk L.vfi/ r/r w11 Ye �rw�r� �J� nn.�� INr'rmn-ypv�.N mruw< <.r�ru ,.mr r.. u �...w,.+u..,�,:rtw...... � _r _ _� _ • �<, s.-. K�a- . . STATE �F COLORADO ASBESTOS CONSULT.ING FIRM Colorada Gepartment nt Public liealth ; a�c,, and Envircmment Air Poiiution Control Di�•ision ``` �' ��-- �.- .,' This certifies that � �-{_ . DS Consulting, Inc. Ite�istrsitioo No. ACF - 1 a912 das mct the regiitralion rcyvircmrU�s i�l 25_7.;p7. C.R.�. ahd the AikfluAiity Control Cummission Regulatiun No. S, Part B. and is hereby antfioriuef to perform asbestos consulting activities as required under Regu►ation No R. Part �, in the statc vf Colorado. � � �, _: 1' . J , lssucd: lanuary 30. 20t2 � <f,- � -�'�` �� �' : Expires: January 30. 2U I3 �� � ��"� ��������/�(L j �� a�_.'. 1 �ww�w wco a�a»a.m,w. -.. � � >_ - _-.. � s __.f-. ,:_ -< 7 `, 86M: :. _.: 11 APPENDIX B ANALYTICAL DATA 12 .� . .�,w�.:�,� � ,�... 139A9 W. Colfvc Av � Suite 20 /�EROLl10LOC�y LAbORATORy Lakewood, CQ 8040 A.�sSC7C-:IATFS, IN(-:C"7RPC)RATFf) 303.232374 C� �� Certificate of Analysis www.aerobioloav.ne ;lient Name DS Consulting �����<>> Date Collected: 03/06/12 itreet address 5366 Flatrock Ct � Date Received: 03/07/12 ;ity, State ZIP Morrison, CO 80465 Date Analyzed: 03/07/]2 �ttn: Steve Shurtliff NVLAP Lab Code 200860-0 Date Reported: 03/07J12 :Iient Project Name: 1635 Golf Terr. Unit 27, Vail, C( ) Project ID: 12002548 Job ID: 'est Requested: 3002, Asbestos in Bulk Samples dethod: Polarized Light Microscopy / Dispersion Staining (PLM), Method f'or the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Sample Identification Homo- Layer Non-Asbestos Non-Fibrous Matrix Physical Description of Sample/Layer geneous percentage Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sam le Number Y/N P rc nt Percenta e Com osition 12002548-1A White Tape N 20% ND 95 5 12002548-1B White Joint Compound N 20% ND 100 C SMI-1 12002548-1C White Compound w/White Paint N 20% ND 100 C 12002548-1D Tan/White Drywall N 40% ND ]0 90 G 12002548-2A White Tape N 20% ND 95 5 SM1-2 12002548-2B White Joint Compound N 40% ND 100 C 12002548-2C White Texture w/Tan Paint N 40% ND 100 C SMl-3 12002548-3 White Texture w/Tan Paint N 100% ND ]00 C 12002548-4A Tan Paper N 20% ND 95 5 SM 1-4 12002548-4B White Tape N 20% ND 95 5 A= Amosite Q= Quartz P= Perlite AC = Actinolite C= Cazbonates B= Binder /� AN = Anthophyilite G= Gypsum D=Diaroms ���_ � .��f�••"'�y`� �� �� CHRY=Chrysotile M = Mica ��� '' �,��� �U CR = Crocidolite T = Tar TR = Tremolite NTR = Non-Asbestiform TR �c ar egrzyn au nappe Trace=Less 1'han 1% NAC =Non-Asbestiform AC Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected Page 1 of 3 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303232.3746 � 13949 W. Colfa�c Av Suite 20 /�EROb1ULOC�y LAbORATOfiy Lakewood, C9 8040 ASSnC:IATFS, IN�:l7RPC7RA7Ff> 303232.374 C' ' �� Certiticate of Analysis www.aerobioloav.ne ;lient Name DS Consulting ��������� Date Collected: 03/06/12 itreet address 5366 Flatrock Ct � Date Received: 03/07/12 ;ity, State ZIP Morcison, CO 80465 Date Analyzed: 03/07/12 \ttn: Steve Shurtliff NVLAP Lab Code 200860-0 Date Reported: 03/07/12 'lient Project Name: 1635 Golf Terr. Unit 27, Vail, CU Project ID: 12002548 Job ID: 'est Requested: 3002, Asbestos in Bulk Samples dethod: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Non-Asbestos Non-Fibrous Matrix Sample Identification Layer Physical Description of Sample/Layer geneous percentage Asbestos Detected Asbestos Percentage Fiber Material Material Client Lab Sam le Number Y/N p r Percenta e Com osition 12002548-4C White Texture w/Tan Paint N 20°/a ND 100 C SM 1-4 12002548-4D White Joint Compound N 40% ND 100 C 12002548-SA White Joint Compound N 10% ND 100 C 12002548-SB White Tape N 20% ND 95 5 SM2-2 12002548-SC White Texture w/Tan Paint N 20% ND 100 C 12002548-SD Tan/White Drywall N 50% ND lU 90 G 12002548-6A White Compound w/Tan Paint N 50% ND 100 C SM2-3 12002548-6B Tan/White Drywatl N 50% ND ]0 90 G Page 2 of 3 A = Amosite AC = Actinolite /� // � u AN = Anthophyllite ���_ ��— ,-y,�� ..� �/srst �'/`z CHRY=Chrysohle 7« CR = Crocidolite TR = Tremolite �c ar egrzyn au nappe Trace=Less Than 1% Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303232.3746 Q = Quartz P = Perlite C = Carbonates B = Binder G = Gypsum D=Diatoms M = Mica T=Tar NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC ,4e�zc�l�ic�lc�yy Lnt�c�rtnic.��ty ASSOCtATES, INCORPORAT[U l'� ���- Certificate of Analysis 13949 W. Colfaac Av Ssite 2C Lakewood, CO 804C 303.232.374 www.aerobioloqv.n� �S Consulting 366 Flatrock Ct 'Iorrison, CO 80465 teve Shurtliff 7ient Project Name: �eneral Notes ❑ ❑ 1635 Golf Terr. Unit 27, Vail, CO ND indicates no asbestos was detected; the method detection limit is 1%. a�dQ��� NVLAP Lab Code 200860-0 Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than 1%. Date Collected: 03/06/12 Date Received: 03/07/12 Date Analyzed: 03/07/12 Date Reported: 03/07/12 Project TD: 12002548 Job ID: ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples. ♦ Aerobiology does not guarantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to particle size, media used, and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND �loes not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the specific sample for the reasons listed above. fotes Required bv NVLAP ♦ ♦ ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the items tested or calibrated. This report is not valid unless it bears the name of a NVLAP-approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. Page 3 of 3 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 ,.'. _:,:� ..;,. ��Z� �� K■ i � CONSUL7ANTS, INC. P.O. 90x 4572 970-949-939 ] � VAIL. CO�GRA00 81658 � FAX 949-157'7 F/ELD REPORT D (� � [� � � [ � JUN u 1 ��' �� TO: THD Construction ATTENTION: Trent Hubbard PROJECT.• Gowen Remodel DATF: AI�R/VE.- DEPART.• WEATHER: 5/24/2012 1:30 pm 2:30 pm Partly Cloudy JOB NUMBER: 7 203-01 PRESENTATS/T� Tim Hennum, Ryan 5chmidt, Trent iiubbard STATUS OF COMPLET/0N: Partial TOWN OF VAIL Observation of framing construction was performed on 5/24/2072 at the requsst of THD Construction. Placement, type, and size of framing members were observed to be consistent with the structural Frami�g Plans, see Gowen Remodel sheet S1. Stair framing not shown on structural pEans conforms with the required Ioading conditions. Steel Column and beam wekled conneciions were observed, no bolting at connetions is required. This report is limited to the observation and loCations of the structural members indicated for the referenced building. Please cortitact KRM Consultants, inc, with any questions. S/GNED: COPY 70: �-' Ry . SChrr►idt . REVIEWED: /.e9:at1 RFl:i��l�. iim D. Hennum, PE" � � - : aa� s� . __ __ . 01-08-2013 Inspection Request .,_:� .,.. .,:.. Page 5 Requested Inspect Date: Wednesday January 09, 2013 Site Address: 1635 GOLF �ERRACE VAIL GOLF COURSE TOWNHOMES UNIT H-27 A/P/D Information Activity: B12-0044 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occu ancy: Use: R-2 Insp Area: Owner: TOLLESbN HN HOWERT�N & SUSAN Contractor: THD COLORADO Phone: 970-376-0008 Description: REBUILD STAIRS AND RAILINGS. REMOVE SEVERAL WALLS IN AND AROUND KITCHEN. ADD NEW STRUCTURE FOR SUPPORT. CREATE NEW KITCHEN AND W ETBAR, UPGRADE FIREPLACE AND ADD THIN STONE CUT VENEER. RELOCATE WASHER AND DRYER. Reauested Inscection(s) Item: 90 BLDG-Final Requested Time: 11:00 AM C oments: 37 DOC�O$OR O Phone: 970-376-0008 Assigned To: J Entered By: JMONDRAGON K Action: Time Exp: Comment: ir ign o E isting window in lower bedroom is over 44" contractor is going to build a landing under window Insoection Historv Item Item Item: ftem: ftem: ftem: ftem: ftem: Item: Item: Item: 6 � 120 ELEC-Rough "` Approved "' 05/17/12 Inspector: sgremmer Action: AP APPROVED Comment: 200 MECH-Rough " Approved " 05/30/12" Inspector: sgremmer Action: AP APPROVED Comment: dyer vent 06/14/12 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: fireplace vent pipe still need to see framing clearances 06/20/12 Inspector: sgremmer Action: AP APPROVED Comment: 220 PLMB-Rough/D.W.V. " Approved " 05/14/1Z Inspector: sgremmer Action: AP APPROVED Comment: 230 PLMB-Rou h/Water "Approved"' 05/14/1� Inspector: sgremmer Action: AP APPROVED Comment: 240 PLMB-Gas Piping " Approved " 05/14/12 Inspector: sgremmer Action: AP APPROVED Comment: 30 BLDG-Framing " Approved "' 06/04/12 Inspector: sgremmer Action: AP APPROVED Comment: Ok per plans and enginee� letter see Laserfiche for engineer letter 50 BLDG-Insulation "' Approved ' 06/08/12 Insp ector: sgremmer Action: PI PARTIAL INSPECTION Comment: still need to see garage 07/05/12 Inspector: sgremmer Action: AP APPROVED Comment: 60 BLDG-Sheetrock Nail " Approved "' 06/20/12 Inspector: sgremmer Action: AP APPROVED Comment: 190 ELEC-Final " Approved '" 12/05/12 Inspector: sgremer Action: AP APPROVED Comment: 290 PLMB-Final " Approved "' 12/05/12 Inspector: sgremer Action: AP APPROVED Comment: 390 MECH-Final "" Approved " �v �3 REPT131 Run Id: 14627 ***++*******++******************+*********+********+*******************++******************* TOWN OF VAIL, COLORADOCopy Reprinted on O1-14-2013 at 09:52:12 O1/14/2013 Statement ******************************************************************************************** Statement Number: R120000611 Amount: $110.00 05/29/201210:36 AM Payment Method: Check Init: MH Notation: ----------------------------------------------------------------------------- Permit No: B12-0044 Type: COMBINATION BLDG PERMIT Parcel No: 2101-091-0402-7 Site Address: 1635 GOLF TERRACE VAIL Location: GOLF COURSE TOWNHOMES UNIT H-27 Total Fees: $2,719.89 This Payment: $110.00 Total ALL Pmts: $2,719.89 Balance: $0.00 *********************+************************************************+********************+ ACCOUNT ITEM LIST: Account Code -------------------- PF 00100003112300 Description Current Pmts ------------------------------ ------------ PLAN CHECK FEES 110.00 -----------------------------------------------------------------------------