HomeMy WebLinkAboutDRB120041 Response to Corrections Notes: Please specify the manufacturer’s name, the color name and number and attach a color chip. Building Materials Type of Material Color Roof . . Siding . . Other Wall Materials . . Fascia . . Soffits . . Windows . . Window Trim . . Doors . . Door Trim . . Hand or Deck Rails . . Flues . . Flashing . . Chimneys . . Trash Enclosures . . Greenhouses . . Retaining Walls . . Exterior Lighting . . Other . . PROPOSED LANDSCAPING Minimum Requirements for Landscaping: Deciduous Trees – 2” Caliper Coniferous Trees – 6’ in height Shrubs – 5 Gal. Please specify other landscape features (i.e. retaining walls, fences, swimming pools, etc.) __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ Botanical Name Common Name Quantity Size PROPOSED TREES . AND SHRUBS . . . . . . . EXISTING TREES . TO BE REMOVED . . . . Type Square Footage GROUND COVER SOD SEED IRRIGATION TYPE OF EROSION CONTROL EIGER CHALETS PAINT SCHEDULE — Post 2006 Face Lift From "Paint Bucket" in Eagle -Vail) I. WOOD: Latex over tinted (close match) oil base primer a. Brown Latex Ben. Moore Ext Stain Siding Acrylic Solid BR 10Y 0.000/32 ID 2106 -30 Pine Cone TG 1 Y 0.000/32 Deep Base W89 3B b. Green Latex Ben. Moore Acrylic Satin Finish OY 2Y 18.000/32 Base 4B BK 3Y 0.000/32 DB C: /G Data BB 1Y 20.000/32 TG 2Y 16.000/32 WH OY16.000/32 Any new or repaired wood should be primered first! II. STUCCO: Originally tinted stucco used a. Bei e/Buff Ben. Moore numbers (Match in "Stolastic" custom) HC-38 Decatur Buff OX IX 11.50 319 -2B RX O X 2.00 BKOX . 4.75 El Rey Stucco Co numbers (Premix Stucco) GJ 3815 -ABC b. Bronzed BeigeYellow) Ben Moore numbers (Match in "Stolastic custom) 2151 -50 FP30 P29 El Rey Stucco Co numbers (Premix Stucco) GJ 3019 III. Metal: Flashing, Chimney Flue & Cap The above wood latex colors can be matched in a DTM Direct to Metal) Ben Moore low luster enamel paint. Clean metal first with a vinegar and water solution. Lopez Renovation Eiger Chalet No. 8 1370 Sandstone Drive Panorama showing rear of units 7, 8 and 9 Rear of Unit 7 existing addition Rear of Unit 8 Rear of Unit 8 Rear of Unit 9 Berridge Tee-Panel Exclusive patented vinyl weatherseal is an integral part of Snap-On Seam*. For residential or commercial construction with solid sheathing. Straight or curved applications. • Available in 24 gauge steel • Hidden fasteners • Extruded vinyl weatherseal as integral part of Snap-On Seam* to prevent siphoning or flooding over seam • Continuous lengths when site-formed with SS-14 portable roll-former • UL 90 wind uplift & UL fire resistance listed • ASTM air & water resistance tested • ASTM E-1592 tested • Florida Product Approval Berridge Manufacturing Company6515 Fratt RoadSan Antonio, Texas 78218(800) 669-0009 • www.berridge.com TEE-PANEL CROSS-SECTION 12 3/4” 324 mm 1” 25 mm Snap-On Seam Cap w/Patented Vinyl InsertTee-Clip Tee-Clip *U.S. Patent No. 4641475 Berridge Curved Tee-Panel Berridge Tee-Panel can be curved to a minimum radius of 4’ for convex and 8’ for concave curved applications using the Berridge SS-14 portable roll former. For specific job application recommendations, please contact Berridge Technical Department at 1-800-231-8127. SPECIFICATIONS (Complete specifications available at www.berridge.com) PRODUCT: Furnish and install Berridge Tee-Panel Standing Seam System as manufactured by Berridge Manufacturing Company, San Antonio, Texas. MANUFACTURE: Tee-Panel provides a 12-3/4” coverage with a 1” seam height (Snap on Seam contains a factory applied vinyl weatherseal insert). Panel and Snap on Seam are available from the factory in continuous lengths to a maximum of 40’-0”. Panel may be field roll formed to virtually unlimited lengths with Berridge SS-14 Portable Roll Former. Panel and Snap on Seam may be field curved with SS-14, both concave and convex to a minimum radius of 4’-0”. WEATHERTIGHTNESS: Certification from independent testing laboratory indicating no measurable air or water penetration through the Snap on Seam in accordance with ASTM E 1680 and E 1646 is required. ENGINEERING: Roof deck shall be of a solid structural sheathing and free of all objects which may puncture underlayment, (entire roof area must be covered with a minimum of number thirty roof felt run horizontally starting at the eave, review Berridge underlayment details for complete installation instructions). Where required, panel assemblies can be constructed to meet Underwriter’s Laboratory UL 90 pursuant to Construction Number 296. Additional UL fire rated assemblies reference Berridge website. MATERIALS, FINISH INFORMATION & CONSTRUCTION DETAILS: Reference web site: www.berridge.com BERRIDGE MANUFACTURING COMPANY KYNAR 500® HYLAR 5000™ COLOR FINISHES TEAL GREEN BURGUNDY DEEP REDMATTE BLACK HARTFORD GREENZINC GREY COLONIAL REDROYAL BLUE HEMLOCK GREEN TERRA-COTTABRISTOL BLUECHARCOAL GREY FOREST GREEN PATINA GREENSHASTA WHITE SIERRA TAN AWARD BLUE COPPER-COTETM LEAD-COTETM PREWEATHERED GALVALUME® ANTIQUE COPPER-COTE CHAMPAGNE ZINC-COTETM NATURAL WHITE All colors except Award Blue comply with LEED® v3 & Energy Star requirements for roof slopes greater than 2:12.Almond complies with LEED® v3 requirements for low slopes.Natural White complies with LEED® v3 & Energy Star requirements for low slopes. BUCKSKIN PARCHMENT AGED BRONZE MEDIUM BRONZE COPPER BROWN DARK BRONZE ALMOND PREMIUM COLORS ACRYLIC-COATED GALVALUME® Berridge premium colors require a nominal surcharge. METALLIC COLORS STANDARD COLORS Berridge metallic colors are premium finishes which require a nominal surcharge.Due to limitations in the printing process, please request actual color chips for accurate color viewing. Due to limitations in the printing process, please request actual color chips for accurate color viewing. NATURAL METAL FINISH Berridge Acrylic-Coated Galvalume® is a coated sheet product that combines the corrosion resistance of GALVALUME® steel sheet with a clear, organic resin applied to the top side and bottom side of GALVALUME® substrate. (800) 669-0009 www.berridge.com * 33 West Beaver Creek Road Richmond Hill Ontario Canada L4B 1L8 ( 800.660.5391 800.660.5390 8 i n f o @ e u r o f a s e .c o m w w w .e u r o f a s e .c o m Recessed multi-light fixture series. Designed for remodel applications but also suitable for new construction applications. Adjustable 35° on both axis for aiming in any direction. Invisible trim with plaster frame. Transformer required, sold separately. Project Information Job Name: Date: Type: Comments: 1-LIGHT MR16 W/TRANSFORMER , 1-LIGHT MR16 SQUARE TRIMLESS MULITPLE Product Specifications Collection: Illuminations Model No.: TE211TR Height: 5.19" Width: 4" Length: 4" No. of Bulbs: 1 Bulb Wattage: 50 watts Bulb Type: MR16/C Bulb Base: GU5.3 Bulb Voltage: 12 volts Options Available ITEM CODE FINISH SHADE TE211TR black n/a Colour / Shades Available FINISH SHADE black n/a + Font Size - XFINITY Connect mha54@comcast.ne RE: Lopez Residence Utility Approval & Verification From : Richard J Sisneros <richard.sisneros@xcelenergy.com> Subject : RE: Lopez Residence Utility Approval & Verification To : Michael A. Hazard AIA <mha54@comcast.net> Cc : Ronnie J Bureta <ronnie.j.bureta@xcelenergy.com> Mon, Feb 27, 2012 09:35 PM Hi Michael, From our phone conversation on the address in question, you are clear to proceed. Xcel Energy High Pressure Gas does not have facilities north of I-70. Operations will respond to your email request as soon as they see it. I forwarded the email this morning as I am on temporary assignment in Denver. Feel free to call any time there may be questions. Thanks, Rich Richard J. Sisneros Xcel Energy | Responsible By Nature Foreman, High Pressure Gas, Silverthorne District Summit County Operations Center 200 W 6th Street, Silverthorne, CO 80498-1819 O: 970-262-4076 C: 970-371-9677 F: 970-468-1401 E:richard.sisneros@xcelenergy.com ________________________________________________ XCELENERGY.COM Please consider the environment before printing this email This email is covered by the Electronic Communications Privacy Act, 18 USC Sections 2510-2521. This email, and any attachments, may contain confidential, private and/or privileged material for the sole use of the intended recipient(s). Any review, use, distribution or disclosure by others is strictly prohibited. If you are not the intended recipient (or authorized to receive for the recipient), please contact the sender by reply mail and delete all copies of this message and any attachments From: Michael A. Hazard AIA [mailto:mha54@comcast.net] Sent: Monday, February 27, 2012 9:45 AM To: samuel tooley; Sisneros, Richard J; jvroom@holycross.com; Bogert, Kathryn Kit; rforsyth@erwsd.org; tony hildreth; daniel roussin Cc: Ivan Lopez; Claes Holm Subject: Lopez Residence Utility Approval & Verification Good Morning, Please find attached a copy of the Town of Vail Forms and associated drawings for a proposed 200 S.F. second floor bedroom extension to an existing Eiger Chalet townhouse in Vail. Please be so kind as to review the material and affix your approvals to the appropriate form. Should you have any questions please feel free to contact me at 970.376.0066. If there is any possibility to complete your review, today (February 27th) it would allow us to meet the Towns submittal deadline for the March Design Review Meeting. Many thanks! Michael A. Hazard AIA Principal Michael Hazard Associates Architecture Planning Interiors P.O. Box 1068 Page 1of 2XFINITY Connect 2/27/2012http://sz0013.ev.mail.comcast.net/zimbra/h/printmessage?id=725600&tz=America/Los_A... UTILI’~ APPROVAL & VERIFICATION This form serves to verify that the proposed improvements will not impact any existing or proposed utility services, end also to verify service availability and location for new construotion and should be used In conjunction with preparing your utility plan and schedul- ing Installations. A site plan, Including grading plan, floor plan, and etevations, shall be submitted to the follovAng utilities for approval and vertfloation. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COMMENTS FROM THE UT.ILITY COMPANIES. If yOU are unable to obtain comreents within that tireeframe please contact The Town of Vail. Subject Property Address: 1370 Sandstone Dr.Lot.__ Bleak___= Subdivision: Prlmary~ontact / O>vner Representative: Michael H_az_ard Phone: 970.949.4958 ,;...//.//~ __ /~//~ ~’ "Plans Dated: 02/24/12 Primar~ Contact/Owner Representative Signature Author z~ ed el nature Comments qWEST 970.468.6860(tal) 970.468.0672(fax) Contacts: Sareuel Tooley sareual.toolev(~owest,com XCEL HIGH PRESSURE GAS 970.262.4076 (tel) )70.468.1401 (fax) :ontact: R{ch Slsneros richard,slsneros(~xcelenerev,cere HOLY CRO. SS ENERGY g70.g47,5471 (tel) 970.945.4081 (fax) 3onta~: .left Vrocm Ijvroom@holycross,cem KCEL Energy ~)70.262.4024 (tel) %ntacts: Kit Bogert Kathrvn.Boeert@xcelenerov.core EAGLE RIVER WATER & SAN 1TA- ~’XON DISTRICT ~70.477.S43S (tat) 970.477,5434 (fax) Contact: Roby Forsybh r~orsvth@erwsd,om COMCAST CABLE 970.619.0752 (tel) 970A6S-2672 (fax) Contact: Tony Hlldreth bmy,_hIld reth@cable.cerecast.core CDOT (Only In CDOT Right-of-way) 970,683.6284 (tel) Contact: Dan Roussln Daniel.roussln@dot,stata,ce,us .NOTES: 1. Utility locations must be obtained before digging, 2, A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way, Contact the Public Works Department for verification 970,479,21.98, 3,It ls the responsibility of the utility company and the applicant to resolve problems Identified above, 4-, The Primary ContacVOwner Representative is required to submit any revised drawings to the above agendes for re-approval & re-verification if the submitted plans are altered In any way after the authorized signature date, UTILITY APPROVAL & VERIFICATION This form serves to verify that the proposed improvements will not impact any existing or proposed utility services, and also to verify service availability and location for new construction and should be used in conjunction with preparing your utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted to the following utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COMMENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact The Town of Vail. Subject Property Address: ____________________________ Lot______ Block _____ Subdivision: ____________ Primary Contact / Owner Representative: ___________________________ Phone: _______________________ ______________________________________________________ Plans Dated: ________________________ Primary Contact/Owner Representative Signature NOTES: 1. Utility locations must be obtained before digging. 2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the Public Works Department for verification 970.479.2198. 3. It is the responsibility of the utility company and the applicant to resolve problems identified above. 4. The Primary Contact/Owner Representative is required to submit any revised drawings to the above agencies for re-approval & re-verification if the submitted plans are altered in any way after the authorized signature date. 03-Mar-10 Authorized Signature Comments Date QWEST 970.468.6860(tel) 970.468.0672(fax) Contacts: Samuel Tooley samuel.tooley@qwest.com XCEL HIGH PRESSURE GAS 970.262.4076 (tel) 970.468.1401 (fax) Contact: Rich Sisneros richard.sisneros@xcelenergy.com HOLY CROSS ENERGY 970.947.5425 (tel) 970.945.4081 (fax) Contact: Jeff Vroom jvroom@holycross.com 2/27/12 XCEL Energy 970.262.4024 (tel) 970.262.4038 (fax) Contacts: Kit Bogert Kathryn.Bogert@xcelenergy.com EAGLE RIVER WATER & SANITA- TION DISTRICT 970.476.7480 (tel) 970.476.4089 (fax) Contact: Fred Haslee fhaslee@erwsd.org COMCAST CABLE 970.619.0752 (tel) 970.468-2672 (fax) Contact: Tony Hildreth tony_hildreth@cable.comcast.com CDOT (Only in CDOT Right-of-way) 970.683.6284 (tel) Contact: Dan Roussin Daniel.roussin@dot.state.co.us + Font Size - XFINITY Connect mha54@comcast.ne RE: Lopez Residence Utility Approval & Verification From : Daniel Roussin <Daniel.Roussin@DOT.STATE.CO.US> Subject : RE: Lopez Residence Utility Approval & Verification To : Michael A. Hazard AIA <mha54@comcast.net> Mon, Feb 27, 2012 04:54 PM There are no issues with CDOT. thanks Dan Roussin Colorado Department of Transportation Region 3 Permit Unit Manager 222 South 6th Street, Room 100 Grand Junction, CO 81501 970-683-6284 Office 970-683-6290 Fax   http://www.coloradodot.info/business/permits/accesspermits From: Michael A. Hazard AIA [mailto:mha54@comcast.net] Sent: Monday, February 27, 2012 9:45 AM To: samuel tooley; richard sisneros; jvroom@holycross.com; kathryn bogert; rforsyth@erwsd.org; tony hildreth; Roussin, Daniel Cc: Ivan Lopez; Claes Holm Subject: Lopez Residence Utility Approval & Verification Good Morning, Please find attached a copy of the Town of Vail Forms and associated drawings for a proposed 200 S.F. second floor bedroom extension to an existing Eiger Chalet townhouse in Vail. Please be so kind as to review the material and affix your approvals to the appropriate form. Should you have any questions please feel free to contact me at 970.376.0066. If there is any possibility to complete your review, today (February 27th) it would allow us to meet the Towns submittal deadline for the March Design Review Meeting. Many thanks! Michael A. Hazard AIA Principal Michael Hazard Associates Architecture Planning Interiors P.O. Box 1068 Vail, Colorado 81658 970.949.4958 P 970.376.0066 C mha@vail.net All information in this Communication, including attachments, is strictly confidential and intended solely for delivery to and authorized use by the addressee(s) identified above, and may contain privileged, confidential, proprietary and/or trade secret information entitled to protection and /or exempt from disclosure under applicable law. If you are not the intended recipient, please take notice that any use, distribution or copying of this Communication, and/or any action taken or omitted to be taken in reliance upon it, is authorized and may be unlawful. If you have received this Communication in error, please notify the sender and delete this Communication from your computer. Page 1of 2XFINITY Connect 2/27/2012http://sz0013.ev.mail.comcast.net/zimbra/h/printmessage?id=725300&tz=America/Los_A...