HomeMy WebLinkAboutB12-0064NOTE: TH/S PERM/T MUST BE POSTED ON JOBS/TE AT ALL TIMES
,.
TtiWN OF YAII, '
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B12-0064
Job Address: 680 LIONSHEAD PL VAIL
Location......: ANTLERS AT VAIL UNIT 204
Parcel No....: 210107206016
CONTRACTOR ANTLERS AT VAIL 03/28/2012 Phone: 970-476-2471
680 W LIONSHEAD PLACE
VAIL
CO 81657
License: C000003092
OWNER LANKENAU, JOHN ERIC & NANCY 04/10/2012
15050 FOOTHILL RD
GOLDEN
CO 80401
Description:
INTERIOR REMODEL OF CONDO TO INCLUDE BEDROOM WALLS,
CLOSETS. BATHROOM REMODEL TO INCLUDE NEW SHOWER, TILE AND
WINDOW. KITCHEN WINDOW WILL ALSO BE REPLACED. WINDOW
REPLACEMENT COVERED UNDER BLANKET DRB060013 APPROVAL.
Occupancy:
Type Construction:
Project #:
Applied.....:
Issued. . . :
PRJ 12-0106
03/28/2012
04/10/2012
Valuation: $75,000.00
...............x....<,...,.,.,.,..,...,..,.....,,,...,,....,.,...,..,..,..,.,...,, FEE SUMMARY ................,...,..,,..........,.,,,,....,.......,..,,.,,........,,.,,,,...
Building Permit -----------> $818.75 Bldg Plan Check ----------> $532.19 Use Tax Fee-----------------------> $1,300.00
Electrical Permit ---------> $115.00 Elec Plan Check -----------> $74.75 Restuarant Plan Review--------> $0.00
Mechanical Permit ------> $0.00 Mech Plan Check ---------> $0.00 Additional Fees--------------------> $0.00
Plumbing Permit --------> $30.00 Plmb Plan Check ---------> $7.50 Recreation Fee--------------------> $0.00
I nvestigation-----------------------> $0.00
Will Call------------------------------> $15.00
TOTAL PERMIT FEES--------------> a2,893.19
Payments-------------------------------> 32,893.19
BALANCE DUE------------------------> 50.00
............................................................................................................................................�....,..,......,,...,...>,.,..,,,.........
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM - 4:00 PM.
Signature of Owner or Contractor
Print Name
combination permit_012811
Date
_ Q t�� �- oP �,
��
(.��T� 1��'jl��( ��/Ei� ����j
�02 � �� I���U,�� .
..............................................�.,............,.,..,,,..,,..,...........,,,....,...,,..................,..,....,...,......,....,,.,,,............,......,,...,,.......
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit#: 612-0064 Address: 680 LIONSHEAD PL VAIL
Owner: LANKENAU, JOHN ERIC & NANCY Location:
ANTLERS AT VAIL UNIT 204
.....................................................................................................................................................................................
combination permit_012811
•
�
T�OWNOF VAIL '
*..,**********************��..*..***********..********�..,.*******************,**��*.�,*�*************�********���*********�**�*..#*********.**�*�**.*
REQUIRED INSPECTIONS AND STATUSES
Permit #: B12-0064 Address: 680 LIONSHEAD PL VAIL
Owner: LANKENAU, JOHN ERIC & NANCY Location:
ANTLERS AT VAIL UNIT 204
.*«**,.*«.**.,****«**«****«.,**,..*.***�..****««**,,,,.,****.,**.�****�,.********««******«.,*......��**..,*******..*.,.,�*....*****«*««*********�*��,.��*«**.,,,*****
Item: 00120 ELEC-Rough
Item: 00200 MECH-Rough
Item: 00220 PLMB-Rough/D.W.V.
Item: 00230 PLMB-Rough/Water
Item: 00030 BLDG-Framing
Item: 00050 BLDG-Insulation
Item: 00060 BLDG-Sheetrock Nail
Item: 00190 ELEC-Final
Item: 00290 PLMB-Final
Item: 00390 MECH-Final
Item: 00534 PLAN - FINAL C/O
Item: 00090 BLDG-Final
combination permit_012811
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
,.
TOWN OF VAII, '
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.4792452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B12-0064
Job Address: 680 LIONSHEAD PL VAIL
Location......: ANTLERS AT VAIL UNIT 204
Parcel No....: 210107206016
OWNER COX FAMILY TRUST
5916 SHERBORN LN
SPRINGFIELD
VA 22152
CONTRACTOR ANTLERS AT VAIL
680 W LIONSHEAD PLACE
VAIL
CO 81657
License: C000003092
APPLICANT COX FAMILY TRUST
5916 SHERBORN LN
SPRINGFIELD
VA 22152
03/28/2012
03/28/2012 Phone:970-476-2471
03/28/2012
Description:
INTERIOR REMODEL OF CONDO TO INCLUDE BEDROOM WALLS,
CLOSETS. BATHROOM REMODEL TO INCLUDE NEW SHOWER, TILE AND
WINDOW. KITCHEN WINDOW WILL ALSO BE REPLACED. WINDOW
REPLACEMENT COVERED UNDER BLANKET DR6060013 APPROVAL.
Occupancy:
Type Construction:
Project #:
Applied.....:
Issued. . . :
PRJ 12-0106
03/28/2012
04/10/2012
Valuation: $75,000.00
,,.,..z....,..�.> ................................................................ FEE SUMMARY ......<....,,.........,.,...,.,...........,.............,.....<x..........,...,
Building Permit -----------> $818.75 Bldg Plan Check ----------> $532.19 Use Tax Fee-----------------------> $1,300.00
Electrical Permit ---------> $115.00 Elec Plan Check -----------> $74.75 Restuarant Plan Review--------> $0.00
Mechanical Permit ------> $0.00 Mech Plan Check ---------> $0.00 Additional Fees--------------------> $0.00
Plumbing Permit --------> $30.00 Plmb Plan Check ---------> $7.50 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $15.00
TOTAL PERMIT FEES--------------> $2,893.19
Payments---------------------°°------> $2,893.19
BALANCE DUE------------------------> $0.00
.................................................,,....,....�,,....,.......,......._.,,.,...,.....,............,,..,�.,...........,.,...........,.............,.......,,.........,..,�..
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM - 4:00 P�
Signature of Owner or Contractor
-ro.,� 5��,1��2
Print Name
combination permit_012811
� I 10 � (Z_
Date
.......................................�......,,,.....,.,,...,,......,........,.,..,.,,...,,......,,...,...,�,....,.,.....,,.....�..........,..........,..�...«..........,,...,,.,.,,
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: B12-0064
Owner: COX FAMILY TRUST
ANTLERS AT VAIL UNIT 204
Address: 680 LIONSHEAD PL VAIL
Location:
...................<,.,....,........,.......�.,,.................,,...,,.....,..,,....�...,................,...,......,...........,....,..,,.....,,,.,.....,.........,...,.......,..,
combination permit_012811
�
1
TiOWN OF VAI� `
***„*.�*..***************..,�.�*************�..*.*�*#.***�**,**.*****..*....��*�**********,..*.,*.******************�**************�.********,**�,**�*.*
REQUIRED INSPECTIONS AND STATUSES
Permit #: 612-0064
Owner: COX FAMILY TRUST
ANTLERS AT VAIL UNIT 204
Address: 680 LIONSHEAD PL VAIL
Location:
,.******�,.*.�***.,*««.,***,,,,*,,,,...�#*********.��*«.,.,***«***#*..*.*.****���,..*,...***,.*«*********.*****,,,,«.,*.,***,.*�***,«*««*«**.,.,****..�*****.,,.««,,,..,****#**.«
Item: 00120 ELEC-Rough
Item: 00200 MECH-Rough
Item: 00220 PLMB-Rough/D.W.V.
Item: 00230 PLMB-Rough/Water
Item: 00030 BLDG-Framing
Item: 00050 BLDG-Insulation
Item: 00060 BLDG-Sheetrock Nail
Item: 00190 ELEC-Final
Item: 00290 PLMB-Final
Item: 00390 MECH-Final
Item: 00534 PLAN - FINAL C/O
Item: 00090 BLDG-Final
combination permit_012811
*********+*�**************�****��******+�*********�+*********���***********************��***
TOWN OF VAIL, COLORADOCopy Reprinted on 04-10-2012 at 11:56:30 04/10/2012
Statement
+*�***********************��*+**�**********��*�*********�*********�r��*******r**+****�******
Statement Number: R120000247 Amount: $2,183.88 04/10/201211:56 AM
Payment Method: Check Init: DR
Notation: ck# 29366
-----------------------------------------------------------------------------
Permit No: B12-0064 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-072-0601-6
Site Address: 680 LIONSHEAD PL VAIL
Location: ANTLERS AT VAIL UNIT 204
Total Fees: $2,893.19
This Payment: $2,183.88 Total ALL Pmts: $2,893.19
Balance: $0.00
*****************************�*****************�********************************************
ACCOUNT ITEM LIST:
Account Code
--------------------
BP 00100003111100
PF 00100003112300
PP 00100003111100
UT 11000003106000
Description
------------------------------
BUILDING PERMIT FEES
PLAN CHECK FEES
PLUMBING PERMIT FEES
USE TAX 4%
Current Pmts
779.13
74.75
30.00
1,300.00
-----------------------------------------------------------------------------
�
TQWN OF VAIL
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970-479-2128
www.vailgov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address:
680 W Lionshead PI
(Number) (Street)
Building/Complex Name: Antlers at Vail
Contractor Information
Business Name: Antlers at Vail
Business Address: 680 W Lionshead PL
City Vail State: CO
Contact Name: Tom Schlader
Contact Phone: 9�0-790-5218
Contact E-Mail: tom@antlersvail.com
204
(Suite #)
Project #: ��� �� — � � � �p
DRB#: _�R,Q(��p QQ�
Building Permit #: — ��
vA t c t�! 0�%S
Lot #: � Block # � Subdivision: �Ic.I�U �
Work Class: New �j Addition (Qj Alteration (Q
Zip: 81657 Type of Building:
Single-Family �j Duplex �j Multi-Family (Qj
Commercial � Other �j
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to
the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other
ordinances of the Town applicable thereto.
Owner/Owner's Representative Signature (Required)
Applicant Information
Applicant Name: Tom Schlader
Applicant Phone: 9�0-790-5218
Applicant E-Mail: tom@antlersvail.com
Project Information
Owner Name: �ohn Lankenau and Nancy Schrant
Parcel #: 2101-072-06-016
(For Parcel #, contact Eagle County Assessors O�ce at (970328-8640 or visit
www.eag lecounty. uslpatie)
For Office Use Only:
Fee Paid:
Received From:
Cash Check #
CC: Visa / MC Last 4 CC #
Auth #
exp date:
Work Type
Electricaf
Mechanical
Plumbing
Building
Interior Q Exterior Q Both �
Valuation of
Work Included Plans Included Work
—..___._._........_.._..___---__ ..............___._._.._.....__..__.__ _......_�_....._._�
�i Yes �1No �Yes QNo 7000
�Yes Q)No QYes �i No
�Yes QjNo �Yes �No 2000
Qi Yes �No QYes QNo 66000
Value of all work being performed: $ 75000
(value based on IBC Section 109.3 & IRC Section 108.3)
Electrical Square Footage 500
Detailed Scope and Location of Work:
Interior Remodel of Condo to include bedroom walls
closets. Bathroom Remodel to include new Shower,
Tile and window. Kitchen window will also be replaced.
Window replacement covered under blanket DRB
approval # 060013.
(use additional sheet if
����uu�
Date Received:
MAR 2 � 2012
�
TOWN OF VAIL
12-Mar-2012
I.and Title
GUARANTEE COMPMIY
�YWW.L�GC.COM
Date: 02-20-2012
Land Title Guarantee Company
CUSTOMER DISTRIBUTION
Our Order Number: V50032865
Property Address:
680 WEST LIONSHEAD PLACE AKA UNIT 204, PARKING SPACE OMEGA 29 ANTLERS VAIL, CO
81657
Ifyou have any inquiries or require further assistance, please contact one of the numbe�s below:
For Closing Assistance•
Henry James
0090 BENCHMARK RD #205
PO BOX 3480
AVON, CO 81620
Phone: 970-477-4520
Faac: 877-268-4359
EMail: hjames@ltgc.com
ANTLERS AT VAIL REAL ESTATE
680 W LIONSHEAD PL
VAIL, CO 81657
Attn: ROB LEVINE
Phone: 970-476-2471
Fax: 970-476-1012
EMail: rlevine@antlersvail.com
Sent Via EMail
COX FAMILY TRUST
5916 SHERBORN LN
SPRINGFIELD VA 22152
Phone: 703-451-8159
EMail: rgcox53@cox.net
Sent Via EMail
LAND TITLE GUARANTEE COMPANY
0090 BENCHMARK RD #205
PO BOX 3480
AVON, CO 81620
Attn: Henry James
Phone: 970-477-4520
Fax: 877-268-4359
EMail: hjames@Itgc.com
03.26.12
For Tide Assistance:
Vail TiUe Dept.
610 WEST LIONSHEAD CIRCLE #200
VAIL, CO 81657
Phone:970-476-2251
Faac: 970-476-4534
EMail: eaglecountyrequests@Itgc.com
FIRSTBANK - VAIL
17 VAIL ROAD
VAIL, CO 81657
Attn: HEATHER LEWIS
Phone: 303-235-4500
Fax: 303-235-4509
EMail: heather.lewis@efirstbank.com
Sent Via EMail
JOHN E. LANKENAU AND NANCY SCHRANT
15050 FOOTHILL RD.
GOLDEN, CO 80401
Phone: 303-941-1094
EMail: johnlankenau@comcast.net
Sent Via EMail
Land Title Guarantee Company
Date:
l.and T�le Our Order Number:
GUARANTEECOMPANV
www.ircC.coM
Property Address:
680 WEST LIONSHEAD PLACE AKA UNIT 204, PARKING SPACE OMEGA 29 ANTLERS
81657
BuyerBorrower:
JOHN E. LANKENAU AND NANCY SCHRANT
Seller/Owner:
THE COX FAMILY TRUST AND ROBERT G. COX AND BARBARA J. COX
Wire Information:
Bank: FIRSTBANX OF COLORADO
10403 W COLFAX AVENUE
LAXEWOOD, CO 80215
Phone: 303-237-5000
Credit: LAND TITLE GUARANTEE COMPANY
ABA No.: 107005047
Account: 2160521825
Attention: Henry James
02-20-2012
V50032865
VAIL, CO
Need a map or directions for your upcoming closing? Check out Land Title's web site at www.ltgc.com
for directions to any of our 54 office locations.
ESTIMATE OF TITLE FEES
ALTA Owners Policy 06-17-06
ALTA Loan Policy 06-17-06
Deletion of Exceptions 1-3 (Owner)
Deletion of General Exception 4(Owner)
Deletion of Exceptions 1-3 (Lender)
Deletion of General Exception 4(Lender)
Endorsement 100 (Lender)
Taac Report R007701
$1, 799. 00
$Z50.00
$60.00
$15.00
$10. 00
$15. 00
$50.00
$25.00
If Land Title Guarantee Cor�any will be closing this transaction, above fees will be co2lected at that time.
Foim CONTACT 06/O4
TOTAL
THANK YOU FOR YOUR ORDER!
$2,124.00
t
First American Title Insurance Company
ALTA COMMITMENT
Our Order No. V50032865
Schedule A Cust. Ref.:
Property Address:
680 WEST LIONSHEAD PLACE AKA UNIT 204, PARKING SPACE OMEGA 29 ANTLERS VAIL, CO
81657
1. Effective Date: February 02, 2012 at 5:00 P.M.
2. Policy to be Issued, and Proposed Insured:
"ALTA" Owner's Policy 06-17-06
Proposed Insured:
JOHN E. LANKENAU AND NANCY SCHRANT
"ALTA" Loan Policy 06-17-06
Proposed Insured:
FIRSTBANK - VAIL
$655,000.00
$491,250.00
3. The estate or interest in the land described or referred to in this Commitment and covered herein is:
A Fee Simple
4. Tide to the estate or interest covered herein is at the effective date hereof vested in:
THE COX FAMILY TRUST AND ROBERT G. COX AND BARBARA J. COX
5. The Land referred to in this Commitment is described as follows:
CONDOMINIUM U1VIT 204, WITH THE EXCLUSIVE RIGHT TO USE PARKING SPACE OMEGA 29,
ANTLERS CONDOMINIUMS, VAIL/LIOIVSHEAD ACCORDING TO THE CONDOMINIUM MAP THEREOF
RECORDED DECEMBER 19, 1972 BOOK 226 PAGE 820 AND AS DEFINED W THE AMENDED AND
RESTATED CONDOMINIUM DECLARATION RECORDED APRIL 3, 2000 RECEPTION N0. 726242,
AND AS FURTHER DESCRIBED IN THE FIRST SUPPLEMENTAL MAP RECORDED JUNE 27, 2000
RECEPTION N0. 733040 AND FIRST SUPPLEMENTAL DECLARATION RECORDED JUNE 27, 2000
RECEPTION NO. 733041 AND SUPPLEMENTAL MAP RECORDED DECEMBER 18, 2001 RECEPTION
N0. 780247 AND SUPPLEMENTAL DECLARATION RECORDED DECEMBER 18, 2001 RECEPTION
N0. 780246, COUNTY OF EAGLE, STATE OF COLORADO.
�.K�� �-_� ��r c,���r ��:«1��� �:�,.��°����,�9 II�o �o
210 Ed�vards V'illage Bl��d. • G202 • P.O. Boi 385
Ed���ards, Colorado 81632
Phone: 970.926.760� • Fa�: 970.926.7610
March 8, 2012
Town of Vail, Building Department
75 South Frontage Road
Vail, Colorado 81657
Re: Lankenau Residence Remodel - Unit 204 Antlers Lodge
Parcel No. - 210107206016
To whom it may concern:
As the Architect for the above referenced project I would like to offer the following information as it
relates to Design Review Board Approval for the attached plans being submitted for Building Permit.
With the exception of the replacement of (2) existing windows on the north side of the unit there are
no changes to the exterior of the building and no increase in the GRFA. It is my understanding from
previous remodels in this building that window replacement falls with in the limits of a blanket
approval granted to the Antlers Lodge by way of File No. DRB060013.
Please call if you have any questions or require additional information.
Sincerely,
ARCHITECTURAL �FtVICES, p.C.
Danny �Vvertf�ge
Copy to: Tom Schlader - Antlers Lodge
- 'ypil FIIZ�c..
i
/
'�,/, � d�'q:.
�.,�
,�� � `_ �,}.��;
OMFR�ENCY SEp�`C��
Vail Fire Department
Asbestos Testing & Abatement Requirements
Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex-
posure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regu-
lations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements
at the contact info listed below.
When is asbestos testin4 reauired?
ANY building projects disturbing more than these threshold levels of building materials require asbestos testing:
One- and Two-Family Dwellings: 32 square feet
All Others (commercial spaces, hotel rooms, etc): 160 square feet
Definition of a single-family dwelling: any dwelling unit that is used primarily for a single family, including
multi-family/condominium units, and fractional fee units.
Asbestos testing results must be provided with your application for a building permit.
Tests which identify POSITIVE results at more than 1% require abatement by a State-certified and Vail-registered abate-
ment contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the
Town of Vail before the building permit will be issued.
Project Checklist
My project falls into the category checked below:
� Will not disturb more than the threshold limits identified above.
� Tested negative, or at 1% or below (1 copies of test results included)
�Tested positive at more than 1%, requires abatement (1 copies of test results included)
Tips & Facts:
• Even recent construction projects may include asbestos-containing materials, so buildings of an age require testing.
• The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit
Court of Appeals vacated much of the so-called Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus,
much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce
of many asbestos-containing product categories was set aside and did not take effect." - CDPHE
Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development,
75 S Frontage Rd, Vail, CO3 81657.
Town of Vail Contact:
Fire Prevention Bureau
Vail Fire Department
75 S Frontage Rd
Fi re_i ns pectors@va i Igov. com
970-479-2252
www.uailqov.com
State of Colorado Contact:
Colorado Department of Public Health
and Environment
Asbestos Compliance Assistance Group
303-692-3158
asbestos@state.co. us
�vG•v�� cdph� state.co.u�
15-May-10
,� � �
� �. � .
�
Asbestos Inspection and Sampling Report
680 W Lionshead Place in Vail, Colorado 81657
Antlers at Vail Unit #204
Presented To:
Mr. Tom Schlader
Antlers at Vail
Director of Preservation
680 W Lionshead Place
Vail, CO 81657
Performed & Prepared By:
Mr. Brian Keyes
DS Consulting, Inc.
PO Box 6864
Avon,CO 81620
970-476-4182
Project Details:
Project Number: 5607
Conducted: March 17, 2012
TABLE OF C ONTENT S
PROJECT OVERVIEW
1.0 Introduction
2.0 Scope of Work
3.0 Site Description
4.0 Certifications
5.0 Inspection, Sampling & Analytical Procedures
5.1 Inspection Procedures
5,2 Sampling Procedures
5.3 Analytical Procedures
6.0 Homogeneous Areas
6.1 Material Friability
6,2 Material Classifications
6.3 Material Conditions
6.4 Sample Quantities
7.0 Overview of Findings
8.0 Conclusion & Recommendations
9.0 Asbestos Abatement & Demolition Requirements
10.0 Major Asbestos Spill Response
11.0 Disclaimer & Limitations
APPENDIX A
APPENDIX B
Inspector & Firm Asbestos Certificates
Analytical Data
2
PROJECT OVERVIEW
1.0 Introduction
On March 17, 2012, Mr. Brian Keyes with DS Consulting, Inc. (DSC) conducted a limited asbestos
inspection and collected asbestos bulk-samples of suspect asbestos-containing materials (ACM) within a
portion of the single-family residence located at 680 W Lionshead Place in Vail, Colorado.
The purpose of the limited inspection was to identify and sample potentially hazardous friable and non-
friable ACM that may be affected by upcoming renovation/remodeling activities.
2.0 Scope of Work
The scope of the limited inspection and bulk-sampling was limited to specific areas of the residence
defined by the building engineer. These areas included the drywall walls in the bedroom and closet
areas. The remaining areas within the residence, or any out-building on the property were not included
in the scope of the inspection. The limited asbestos inspection did not constitute a full building inspection
and does not fulfill the asbestos inspection requirements for structures that are to be demolished.
3.0 Site Description
The residence is a wood-framed, single-family condominium within a larger, multi-unit building.
4.0 Certifications
The limited asbestos inspection and bulk-sampling was conducted by Mr. Brian Keyes with DSC. DSC is a
Colorado Department of Public Health and Environment (CDPHE) certified Asbestos Consulting Firm,
Registration No. 14912. Mr. Keyes is a CDPHE certified Building Inspector; having certification number
5966 (see Appendix A for certificates).
5.0 Inspection, Sampling & Analytical Procedures
5.1 Inspection Procedures
The limited asbestos inspection was conducted by an Environmental Protection Agency (EPA) and
CDPHE certified Building Inspector. The inspection procedures included identifying and sampling
suspect ACM within the pre-defined areas, submitting samples to an accredited laboratory for analysis,
classifying the materials and assessing their condition, and compiling a final report detailing the
inspection and the analytical results of the bulk-samples.
5.2 Sampling Procedures
Statistically random bulk-samples representative of the suspect ACM of each homogeneous area were
collected according to the guidelines published as EPA Final Rule: Title II of the Toxic Substances
Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763 and
CDPHE Regulation Number 8, Part B- Asbestos (Reg. 8).
DSC has collected the appropriate number of bulk-samples to meet all regulatory requirements for the
classification and quantity of each homogeneous area. Some minor destructive sampling was
conducted; however, walls, columns and perimeter pipe chases were not broken into in order to locate
3
and quantify suspect ACM. It should be noted that additional ACM might be located in these and other
inaccessible areas.
Materials containing less than 1% asbestos are not regulated by CDPHE Regulation 8, Part B- Asbestos.
However, all demolition/abatement activities should be performed following the applicable
Occupational Safety and Health Administration (OSHA) regulations. This would include, but not limited
to, the appropriate asbestos training for the rype of material being removed/disturbed as well as having
a properly trained supervisor onsite, using wet removal methods, wearing adequate personal
protective equipment (HEPA-filtered particulate respirators), medical surveillance of workers,
personal-exposure air monitoring, area air monitoring in occupied buildings, etc. There may also be
landfill disposal requirements for these materials, depending on the facility. DSC recommends that all
demolition/renovation areas involving any amount of asbestos be subjected to visual inspections and a
final clearance air testing by a CDPHE-certified Air Monitoring Specialist (AMS) after the work has been
completed, but before any containments are dismantled and the area is reoccupied.
5.3 Analytical Procedures
All asbestos bulk-samples were analyzed by a National Voluntary Laboratory Accreditation Program
(NVLAP) accredited laboratory via Polarized Light Microscopy (PLM) for asbestos content (see
Appendix B for laboratory report). ,
The percentage of asbestos within each individual bulk-sample can vary depending on sample location,
homogeneity of the material, and the type of application. Any sample reporting a TRACE amount of
„ �,
asbestos must be considered positive for asbestos greater than 1% unless it is re-analyzed utilizing the
point-count method and verified to be less than 1%.
6.0 Homogeneous Areas
A Homogeneous Area (HA) includes materials that are uniform in appearance, color, texture and date of
application. The asbestos content of the bulk-samples collected within a homogeneous area can be
applied to the entire homogenous area if they conform to the above characteristics and the regulated
minimum sample quantities of each type of material are collected and analyzed.
6.1 Material Friability
A material can either be friable or non friable. A friable material is one that, when dry, can be
pulverized, or reduced to powder by hand pressure, a non-friable material cannot. A non-friable
material may become friable if its condition had deteriorated or has been impacted by forces that have
rendered it friable.
6.2 Material Classifications
Sampled materials are divided into one of the following three categories:
• Surfacing Material: sprayed or troweled onto structural building members
• Thermal System Insulation (TS/): any type of pipe, boiler, tank, or duct insulation
• Miscellaneous Material: all other materials not classified in the above two categories
6.3 Material Conditions
Sampled materials are placed into one of the three following categories of conditions:
�
• Good: none to very little visible damage or deterioration
� Damaged: the surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded
over less than one-tenth of the surface if the damage is evenly distributed,. or one-quarter if the
damage is localized
• Significantly Damaged: the surface is crumbling, blistered, water-stained, gouged, marred or
otherwise abraded over greater than one-tenth of the surface if the damage is evenly distributed,
or one-quarter if the damage is localized
6.4 Sample Quantities
DSC collected at least the minimum number of samples from each homogeneous area necessary to meet
all regulatory requirements for the quantity of material to be disturbed. The quantities listed in this
report are approximate and on-site verification of the exact quantity of each material is required. The
following outlines the minimum sample quantities required per homogeneous area:
• Surfacing Materials: up to 1,000 ft2 of material requires a minimum of three (3) samples; between
1,000 ft2 and 5,000 ft2 of material requires a minimum of five (5) samples; over 5,000 ftz of
material requires a minimum of seven (7) samples; one (1) sample of each patch
• Thermal System Insulation (TS!): each homogeneous area requires a minimum of three (3)
samples; at least one (1) sample must be collected from each patch; and collect enough samples
sufficient to adequately assess the material and determine the asbestos content for TSI fittings
such as pipe elbows or T's.
• Miscellaneous Materials: collect enough samples sufficient to determine the asbestos content
7.0 Overview of Findings
Asbestos was reported within the bulk-samples collected and analyzed. DSC collected a total of three (3)
asbestos bulk-samples of one (1) homogeneous area. Both the closet wall drywall texture and joint
compound were found to contain asbestos at 2% Chrysotile.
Table 1 below describes the materials composing each homogeneous area as well as the locations of each
bulk-sample collected. Also listed is the classification, condition, friability and estimated quantity of
material to be removed and/or disturbed, as well as the asbestos content within each bulk-sample.
Please see Appendix B: Analytical Data for the layer break-down of each bulk-sample.
5
TABLE 1
HA Sample Material Sample Material Material Estimated Material Asbestos
# ID Description Location Classification Condition Quantity Friability Content
Tan-paiizted Drywall
1 DW01 Texture and ]oint Closet Gast Wall SM G M£�0 ft'- Friable 2%
Campound
Tan-painted Drywall
1 DW02 Texture and ]oint West side of wall, center SM G �t30 ft'- Fi•iable 2%
Compound
Tan-painted Drywall East side of wall behind
1 DWU3 Texture and Joint �resser SM G �80 ft2 Friable 2%
Compaund
HA - Homogeneous Area
ND - None-detect
TR - Trace, <1% Visual Estimate
G - Good
D - Damaged
SD - Significantly Damaged
CHRY - Chrysotile
ACT - Actinolite
SM - Surfacing Material
MM - Miscellaneous Material
TSI - Thermal System Insulation
8.0 Conclusion & Recommendations
IMMEDIATE: The laboratory results of the potential ACM sampled within the residence indicate that one
or more the drywall texture and joint compound were positive for asbestos at 2% Chrysotile.
ACM was identified within the areas of the residence that were within the scope of the limited inspection
and bulk-sampling performed on March 17, 2012; therefore a licensed asbestos abatement contractor is
required to perform the removal, including formal notification to the Colorado Department of Public Health
and Environment prior to the abatement of the ACM if total quantity exceeds any of the regulatory trigger
levels.
9.0 Asbestos Abatement & Demolition Requirements
If ACM is to be removed or disturbed in a single-family residence, and the total quantity exceeds any of
the regulatory trigger levels of 50 linear ft. on pipes, 32 ft2 on other surfaces, or the volume equivalent of
a 55-gallon drum, a CDPHE-certified General Abatement Contractor (GAC) is required to perform the
work. The regulatory trigger levels within a commercial building are 260 linear ft. on pipes, 160 ftz on
other surfaces, or the volume equivalent of a 55-gallon drum. In addition, formal notification to CDPHE
prior to the abatement of ACM as well as air monitoring, visual inspections, and final air clearances by a
CDPHE-certified Asbestos AMS is required. DSC can provide the client or building owner with a proposal
for project design, abatement oversight and air monitoring upon request.
CDPHE regulations allow for the demolition of a building that contains non-friable asbestos-containing
materials, such as caulking, mastic or resilient floor tiles. However, demolition must be completed
without causing the non-friable ACM to be rendered friable. Burning a building with any ACM is
prohibited. Operations such as sanding, cutting, crushing, grinding, pneumatic jacking, etc. of ACM are
not permitted. Recycling of building materials such as concrete, metal, or wood that are bonded or
contaminated with ACM, e.g. glue, caulking, or mastic is also prohibited. If any of the non-friable asbestos
containing materials are to be recycled and rendered friable after demolition (i.e. crushing mastic-coated
concrete), these materials must be abated of all ACM prior to shipping offsite for recycling.
OSHA regulations regarding occupational exposure during demolition activities is still mandatory. OSHA
29 CFR 1926.1101 requires that workers performing construction-related activities be protected from
asbestos fibers in excess of the permissible exposure limit of 0.1 f/cc of air. Contractors are must comply
with applicable provisions of OSHA 29 CFR 1926.1101 during demolition and renovation activities.
These OSHA provisions include, but are not limited to, PPE and respirators, personnel training, personal-
exposure air monitoring, employee medical surveillance, wet removal methods, signage for regulated
areas, etc.
10.0 Major Asbestos Spill Response
If ACM is significantly damaged and the total quantity exceeds the regulatory trigger levels, the area is
deemed a"Major Asbestos Spill." The area is consequently subject to the requirements in Reg. 8, Section
III.T.1. - MajorAsbestos Spills, as outlined below. Additional asbestos air or dust sampling should also be
conducted within the remaining areas not directly impacted by the Major Asbestos Spill to determine if
asbestos-containing dust/debris has spread to adjacent areas. If asbestos fibers are found within any
other areas or on building contents, they should be included in the scope of professional abatement and
decontamination. The following response actions must be followed per Colorado Reg. 8 when a Major
Asbestos Spill occurs:
• Restrict access to the area and post warning signs to prevent entry to the area by persons other
than those necessary to respond to the incident.
• Shut off or temporarily modify the air handling system to prevent the distribution of asbestos
fibers to other areas.
• Immediately contact the Division by telephone, submit a notification in compliance with
subsection III.E. (Notifications) and, if in an area of public access, apply for a permit in accordance
with subsection III.G. (Permits).
• Be exempted from the requirements to have a certified Supervisor on-site at all times, until such
time as the immediate danger has passed. Any cleanup or asbestos abatement that must occur
after the immediate danger has passed shall be supervised by a person certified by the Division.
• Using certified Supervisors and certified Workers in accordance with section II. (Certification
Requirements) of this Regulation, seal all openings between the contaminated and
uncontaminated areas and establish none-detect air pressure within the contaminated area in
accordance with paragraph III.J. (Air Cleaning and None-detect Pressure Requirements). This is to
be accomplished using polyethylene sheeting to cover areas such as doorways, windows, elevator
openings, corridor entrances, grills, drains, grates, diffusers and skylights.
• HEPA vacuum or steam clean all carpets, drapes, upholstery, and other non-clothing fabrics in the
contaminated area, or discard these materials.
• Launder or discard contaminated clothing in accordance with subsection III.R. (Waste Handling).
• HEPA vacuum or wet clean all surfaces in the contaminated area.
• Discard all materials in accordance with subsection III.R. (Waste Handling).
• Following completion of subparagraph III.T.1.a. through III.T.1.i. above, comply with air
monitoring requirements as described in subsection III.P. (Clearing Abatement Projects); air
samples shall be collected aggressively as described in 40 C.F.R. Part 763, Appendix A to Subpart
E(EPA 1995), except that the air stream of the leaf blower shall not be directed at any friable ACM
that remains in the area and
• Comply with any other measures deemed necessary by the Division to protect public health.
11.0 Disclaimer & Limitations
The activities outlined in this report were conducted in a manner consistent with a level of care and
expertise exercised by members of the environmental consulting and industrial hygiene profession. All
activities were performed in accordance with all applicable federal, state, and local regulations as well as
generally accepted standards and professional practice. No warranty is either expressed or implied. DSC
assumes no responsibility or liability for error in public information utilized, statements from sources
other than DSC, or developments resulting from situations outside the scope of this project.
The details provided within this report outline the inspection activities on the date(s) indicated and
should not be relied upon to represent conditions at a later date, the limited number of bulk-samples
collected, and the laboratory results of those bulk-samples. The laboratory results contained in this
report apply specifically to the materials in which bulk-samples were collected. The results do not
include or apply to any other materials within the structure that were not sampled, but may contain
asbestos; including materials that may be hidden or inaccessible. Additional inspection and bulk-
sampling activities would be required to determine if any other materials contain asbestos.
This report has been prepared on behalf of and exclusively for use by the Client, with specific application
to their project as discussed in the scope of work. The results of any surfacing material indicated in this
report also includes any associated overspray of that material, e.g., under carpet, above suspended
:
ceilings, etc. The information contained in this report is intended as supplementary material for
abatement design and is not to be used as the scope of work for abatement activities, bidding or billing
purposes. Contractors or consultants reviewing this report must draw their own conclusions regarding
further investigation or remediation deemed necessary. DSC can provide a full scope of work for
abatement upon request. DSC does not warrant the work of regulatory agencies, laboratories or other
third parties supplying information which may have been used in the preparation of this report.
G�
APPENDIX A
ASBESTOS FIRM CERTIFICATE
���i sC 3 " t ri�is x. ,�i�. ".� �y�.�.`S s ;. ira� s 3� 3ss� t ., ,�-�,y � r#-''"wr� 3ss a^� 'F
} � 't ��� di .> � xv � ��r+a{���; � yJ�(! . 'eL� � � . � EJ , ( �,
� �.. 'p .. ' .y� ✓ ; �
b y � {
� ,r� �r �'r. � i i h . .,. � f "� r � � .
.
� � � f 4 � �� t' � �t S 7? f't+ �q ,t 'i r t Y�`Y \ I- � � � � � � �i � � i.. �'S .t ' r� i'� � �L �z 1 � I 4s _>'^_. � •
� ._.. ,. . . ..._ .,...., � . . . , ,
� \
�� � . ,. _,. _ . ., _ ... . . . . . �L� ��"•��
� ����
�� �, sTnrre c�F� cc�LO��I�c-> :��' �.
� ��, �
�
�� � a ����
��. �; <�SE3f:5`I'{)ti C'O��E�I,"t iti(: E°IIZiYt 1�, ;
{ ,.. � �
.F � fz
�>� ��� � (.�ul���.id„ 13� �,rt�m�n �.f C'uhl�c [�Ieaith � ?,,x' ��y
� ��" mc I�:nvat,nn:,�7i '� �
�; � s
-' � �lir Feal<utiortC�rn;uol t�i<iainn � ` ��'
� " � �
Y,sy� t � ; � .�. . � A.
i
� ��t�`t ��
��� t` �*' : .�: � �:':5 i:i'ntii�'.`. ?ll:it � � Y� � p��'
�� � �d� �.. � . .1� �
, °`�-�::, DS (_'oiisu(ti�t�;, Inc. , � �
t°��,�
< � > r��
� �i:
�� ,r'�;,` Rc�icir:iliuu tio.:�f'(� - 1a912 �ts1 ��,
s�'- �t' ; i� ,r �t�
� � i ��: nc't tE ��c}ti � qi„ts rc �stt c�rtr �t� r?.`",� !.. C: t. ��:hd !I � 4ir Q il�t� Cut�tral �/� a�,
���o' i+ ttrti.,� u t2c�.ui ui ,u N:� � I�.trt 13 �nd re h[r�h atNl:untcd ��� p ali im :"h�it��.t�3i ulnra« '�
a �� ' a.tivi�i�� .�. ri.��t�cccl u,t�lcr iicEUl.el�,�tt �,+ �. ,Pa[t R� in tilt .lat: c�( tlilor.idh�. '� �` �
r�� `�l'y � ��
nF; ��� . . . ,i t 4=�
y l ��
F� � �
����a Iti�u�d i:a�ui�� z� i112 y� s�
4 4-, w• � t'� r i�
� � f',x�)ttcs, fattu_it�' 311. _!I t + � , �� r . �,;
� •�. .. .. . . Aun.^•��kdaLV.tsF,�tpwiv`�3 �,`�`�
�.�r /` ' , � { ` .�} Y
F
i Y `v: X
� �LC . . . . .'_ . : �. . .�:, � � �
' �.. '� � � 5 ,`'� f ° z. t� �i�i ' i � � q,�J�( � ;�- n y- { '7 � °. � ' t � � � :
� � �il� f 41�r �I � li �� ��+ � �t,�i y. ft ��1 i .' � l �� ^� �1 ti�w i� f 1 � � ! ti� .
t A � / .�� �' �� �:-� �
4
t l�* `4`s�
�w i'�,,�'"c d'n �. "x' ! `.«� b � . .
i �-�... �� g� ^h"•�e5�+� h�?T � t! �� a t�
T»A I [41-ftr{ t y, �4. S. �.+E V
�.ci.z...�2,�.,� �i�., ._..� .`tiY + F�.s:�A.ih.: . � . li. . . ;. � . . .. - _ � �' .. •
10
APPENDIX B
ANALYTI CAL DATA
11
y/ Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/l 16
Homo- Layer �
Physical Description of Sample/Layer geneous Asbestos Detected Asbestos Percentag
��,�� Percentage
White Joint Compound N 1% CHRY 2
White Tape N 2% ND
White Texture w/Tan Paint (top) N 3% ND
White Texture w/Tan Paint (lower) N 3% CHRY 2
Tan/White Drywall N 91 % ND
White Paint N 25% ND
White Texture w/Tan Paint N 25% ND
Tan/White Drywall N 50% ND
y/ Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116
Physical Description of Sample/Layer
Tan/White Drywall
Homo-
Layer
geneous
�Y�� Percentage
N 80%
Asbestos Detected
�
Asbestos Percentag
u v u v u-v�
NVLAP Lab Code 200860-0
at Vail Unit #204
-D�
D�
; was detected; the method detection limit is 1%.
�sbestos was identified in the sample, but the concentration is less than 1%.
inerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sar
nosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the a
ral riebeckite.
and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibE
ve analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is require
nder NESHAP regulations.
ed pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's �
onsibility or liability is assumed for the manner in which the results are used or interpreted.
; to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minirr
and handling charge will be assessed for the return of any samples.
�.rantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to pa:
lysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not
�stos in the specific sample for the reasons listed above.
i
y
06-28-2012 Inspection Request Reporting Page 12
4:26 pm Vail, C� Of
Requested Inspect Date: Friday, June 29 2012
Site Address: 680 L10NSHEA� PL VAIL
ANTLERS AT VAIL UNIT 204
A/P/D Information
Activity: 612-0064 Type: COMBO Sub Type: AMF
Const Type: Occup ancy: Use:
Owner: LANKENAU, JOHN ERIC & NANCY
Contractor: ANTLERS AT VAIL Phone: 970-476-2471
Status: ISSUED
Insp Area:
Description: INTERIOR REMODEL OF CONDO TO INCLUDE BEDROOM WALLS CLOSETS. BATHROOM REMODEL
WINDOW REPLEi4CEME�NT C�VEREDNUNDER BLWAIVKET DR606001�3�APPRIOVALSO BE REPLACED.
Requested In tion s
: 534 PLAN - FINAL C/O
stor: ANTLERS AT VAIL
ments: 476-2471
ssi ed To: BGIBSON
�
'on: Time Exp:
Item: 90 BLDG-Final
Requestor: ANTLERS A IL
Comments: 476-2471
Assigned To: J R
Action:
Inspection Historv
Item: 120 ELEC-Rough
05/17/12 Inspector:
Comment:
Item: 200 MECH-Roug h
05/15/1Z- Inspector:
Comment:
Item: 220 PLMB-Rough/D.W.V.
05/08/1Z Inspector:
Comment:
Item: 230 PLMB-Rough/Water
^05/08/1Z Inspector:
Time Exp:
•" Approved *`
sgremmer
*` Approved *`
sgremmer
** Approved **
sgremmer
*" Approved **
sgremmer
Requested Time: 08:30 AM
Phone: 970-476-2471
Entered By: JMONDRAGON K
Requested Time: 01:00 PM
Phone: 970-476-2471
Entered By: JMONDRAGON K
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Item: 30 BLDG-Framing *` Approved **
05/15/12 Inspector: sgremmer Action: DN DENIED
Comment: Elect. rough to be completed
Seal all penitrations at both east and west wall plumbing�and Elect. pipes
05/17/12 Inspector: sgremmer Action: A� APPROVED
Comment:
Item: 50 BLDG-Insulation *" A� pproved *'
05/24/12 Inspector: JRM
Comment:
Item: 60 BLDG-Sheetrock Nail *" Approved "*
05/24/12 Inspector: JRM
Comment:
Item: 190 ELEC-Final ** Approved '"
06/27/12 Inspector: sgremmer
Comment:
Item: 290 PLMB-Final "" Approved `*
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
REPT131 Run Id: 14593
\�
06-25-2012 inspection Request Reporting Page 9
4:25 qm Vail,s� Citv �f
Requested Inspect Date: Tuesday' June 26 2012
Site Address: 680 LIONSHEAD f�L VAIL
ANTLERS AT VAIL UNIT 204
A/P/D Information
Activity: 612-0064 Type: COMBO Sub Type: AMF
Const Type: Occup ancy: Use:
Owner: LANKENAU, JOHN ERIC & NANCY
Contractor: ANTLERS AT VAIL Phone: 970-476-2471
Status: ISSUED
Insp Area:
Description: INTERIOR REMODEL OF CONDO TO INCLUDE BEDROOM WALLS CLOSETS. BATHROOM REMODEL
WINDOW REPL4CEMENT C�VEREDNUNDER BLWANKET DRB060�01�3°APPR�OVALSO BE REPLACED.
Repuested Inspection(s)
Item: 190 ELEGFinal
Requestor: ANTLERS AT VAIL
Comments: 476-247
Assigned To:
Action: Time Exp:
Item: 2 0 PLMB-Final
Requestor: ANTLERS AT VAIL
Comments: 476-2471
Assigned To: SGR
___ _ _ __ ______ _ Action: _ . _Time Exp:
Item: 390 MECH-Final
Requestor: ANTLERS AT VAIL
Comments: 476-2471
Assigned To: SG
Action: Time Exp:
Inspection Historv
Item: 120 ELEC-Rough "" Approved **
05/17/1Z Inspector: sgremmer
Comment:
Item: 200 MECH-Rou h ** Approved **
05/15/1� Inspector: sgremmer
Comment:
Item: 220 PLMB-Rough/D.W.V. ** Approved **
05/08/1Z Inspector: sgremmer
Comment:
Item: 230 PLMB-Rough/Water "" Approved "*
05/08/1Z Inspector: sgremmer _ Action: AP APPROVED
--- -- Comment:----- ---- - -- _
_ _ _ _ -_ ___ _ __ - --- _ . _
Item: 30 BLDG-Framin4 '* Approved ""`
sgremmer Action: DN DENIED
h to be completed
�itrations at both east and west wall plumbing and Elect. pipes
sgremmer Action: AF� APPROVED
*'' A� pproved ""
JRM Action: AP APPROVED
Requested Time: 11:30 AM
Phone: 970-476-2471
Entered By: JMONDRAGON K
Requested Time: 02:00 PM
Phone: 970-476-2471
Entered By: JMONDRAGON K
Requested Time: 02:30 PM
Phone: 970-476-2471
Entered By: JMONDRAGON K
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Comment: Elect. rou�
Seal all pE
05/17/12 Inspector:
Comment:
Item: 50 BLDG-Insulation
05/24/12 Inspector:
REPT131 Run Id: 14575
� �
y
�
� ia-o�o�
06-28-2012 Inspection Request Reporting Page 12
4:26 nm Vail, CO . Citv �f
Requeated Inspect Date: Friday June 29 2012
Site Address: 680 UbNSHEA� PL VAIL
ANTLERS AT VAIL UNIT 204
A/P!D Information
Activity: 612-0064 Type: COMBO Sub Type: AMF Status: ISSUED
Const Type: Occup ancy • Use: Insp Area:
Owner: LANKENAU, JOHN ERIC 8 NARCY
Contractor: ANTLERS AT VAIL Phone: 970-476-2471
Description: INTERIOR REMODEL OF CONDO TO INCLUDE BEDROOM WALLS CLOSETS. BATHROOM REMODEL
WINDOW REPL4CEMENT C�VEREDN�NDER BLWAIVKET DRB06001�3�APPR�OVALSO BE REPLACED.
534 PLAN - FINAL C/0 Requested Time: 08:30 AM
ANTLERS AT VAIL Phone: 970-476-2471
476-2471
BGIBSON Entered By: JMONDRAGON K
'on: Time Exp:
� . �� �' � �
Item: 9 BLDG-Final Requested Time: 01:00 PM
Requestor. ANTLERS A IL Phone: 970-476-2471
Comments: 476-2471
Assigned To: J R Entered By: JMONDRAGON K
Action: Time Exp:
Inspection Historv
Item: 120 EL��
Item: 200 MEC
e
Item: 220 PLMI
�
Cor
Item: 230 PLMI
'* Approved'"
Inspeetor: sgremmer
�Inspector: sgremmpeoved "`
ID.W.V. " Approved "
Inspector: sgremmer
IWater •" Approved "
Inspector. sgremmer
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Item: 30 BLDG-Framing " Approved "
05N5/12 Inspector: sgremmer Action: DN DENIED
Comment: Eled. rough to be completed
Seal all penitrations at both east and west wall plumbing a�nd Elect. pipes
OS/17/12 Inspector. sgremmer Action: A� APPROVED
Comment:
Item: 50 BLDGlnsulation "A� pproved "'
05l24/12 Inspector: JRM Action: AP APPROVED
Comment:
Item: 60 BLDGSheetrock Nail " Approved "
05l24/12 Inspector. JRM Action: AP APPROVED
Comment:
Item: 190 ELEC-Final "Approved "
06/27/12 Inspector. sgremmer Action: AP APPROVED
Comment:
Item: 290 PLMB-Final '* Approved *'
REPT131 Run Id: 14593
M •
�
rting
Page 12
Requested Inspect Date: Friday February 01, 2013
Site Address: 680 L1bNSHEAD PL VAIL
ANTLERS AT VAIL UNIT 204 �
A/P/D Information � ��
Activity: B12-0064 Type: COMBO Sub Ty pe: AMF Status: ISSUED
Const Type: Occupancy : Use: Insp Area:
Owner: LANKENAU, JOHN ERIC & NAIVCY
Contractor: ANTLERS AT VAIL Phone: 970-476-2471
Description: INTERIOR REMODEL OF CONDO TO INCLUDE BEDROOM WALLS CLOSETS. BATHROOM REMODEL
WINDOW REPLEi4CEMENT CdVERED UNDER BLWi41VKET DRB06001�3�APPRIOVA�SO BE REPLACED.
Reauested Inspection(s)
Item: 90 BLDG-Final
Requestor:
Comments: Follow-u
Assigned To: SGREM E1�
Action: Time Exp:
Comment:
Requested Time: 01:00 PM
Phone:
Entered By: MHAEBERLE K
Insuection Historv
Item: 120 ELEC-Rough " Approved '"
05/17/12 Inspector: sgremmer Action: AP APPROVED
Comment:
Item: 200 MECH-Rou h " Approved "
05/15/1 � Inspector: sgremmer Action: AP APPROVED
Comment:
Item: 220 PLMB-Rou h/D.W.V. " Approved "
05/08/1� Inspector: sgremmer Action: AP APPROVED
Comment:
Item: ± 230 PLMB-Rough/Water "' Approved "
05/08/1 Z Inspector: sgremmer Action: AP APPROVED
Comment:
Item: 30 BLDG-Framing '* Approved "
05/15/12 Inspector: sgremmer Action: DN DENIED
Comment: Elect. rough to be completed
Seal all penitrations at both east and west wall plumbing�and Elect. pipes
05/17/12 Inspector: sgremmer Action: AF� APPROVED
Comment:
Item: 50 BLDG-Insulation ** A� pproved "'
05/24/12 Inspector: JRM Action: AP APPROVED
Comment:
Item: 60 BLDG-Sheetrock Nail *' Approved "
05/24/12 Inspector: JRM Action: AP APPROVED
Comment:
Item: 190 ELEC-Final " Approved '*
06/27/12 Inspector: sgremmer Action: AP APPROVED
Comment:
Item: 290 PLMB-Final " Approved "
06/27/12 Inspector: sgremmer Action: AP APPROVED
Comment:
Item: 390 MECH-Final " Approved "
06/27/12 Inspector: sgremmer Action: AP APPROVED
Comment:
Item: 534 PLAN - FINAL C/O " Ap pro�ved "
07/05/12 Inspector: Warren Action: AP APPROVED
Comment:
Item: 90 BLDG-Final " Approved "
07/02/12 Inspector: sgremmer Action: AP APPROVED
REPT131 Run Id: 15058