Loading...
HomeMy WebLinkAboutB12-0085 NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ��� �. �o�o���:�� Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0085 Project #: PRJ12-0125 Job Address: 181 W MEADOW DR VAIL Applied.....: 04/04/2012 Location......: VAIL VALLEY MEDICAL CENTER Issued. . . : 05/07/2012 Parcel No....: 210107101013 OWNER VAIL CLINIC INC 04/04/2012 IN CARE OF VAIL VALLEY MEDICAL CENTER PO BOX 40000 VAIL CO 81658 CONTRACTOR AMERICAN MECHANICAL SERVICES 04/04/2012 Phone: 877-637-7397 GYPSUM OFC- 770 LINDBERGH DR 3231 S ZUNI ST ENGLEWOOD CO 80110 License: 128-M APPLICANT VAIL CLINIC INC 04/04/2012 IN CARE OF VAIL VALLEY MEDICAL CENTER PO BOX 40000 VAIL CO 81658 Description: REMOVE OLD TSI CHILLER AND INSTALL NEW CARRIER CHILLERS. MODIFY ELECTRICAL AND MECHANICAL AS REQUIRED. CHILLER LOCATED IN BASEMENT MECHANICAL ROOM, CONDENSER LOCATED OUTSIDE BEHIND CONCRETE WALL.THERE IS EXISTING EQUIPMENT IN BOTH AREAS. Occupancy: Type Construction: Valuation: $158,950.00 ...................,�x.............,>...,.......,,�..,.�.,................,,......, FEE SUMMARY .,,...<.�.,,.<,,,,............,..,..,.,....,.�..,.�..............,......,............ Building Permit-----------> $1,324.15 Bldg Plan Check----------> $860.70 Use Tax Fee-----------------------> $2,979.00 Electrical Permit---------> $603.75 Elec Plan Check-----------> $392.44 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $2,860.00 Mech Plan Check---------> $715.00 Additional Fees--------------------> $2,184.85) Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $10.00 TOTAL PERMIT FEES--------------> $7,560.19 Payments-------------------------------> $7,560.19 BALANCE DUE------------------------> $0.00 ....,.>_.>..........................................................>...,�,.......,,.,.,,.,.........,.........>.,....,.,.,_,..�,,,...,�_...,.,,..,....,...................._..,..,,.��.,., DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit_012811 -__. ` � � � ����if��� 1 ... � ....a�ti�w*�.x+.�+aa�.a:..�.�...x��++��++:��+.�:.a..y+a�+�+��...+«:.��>�+t..�...a+�:r>+++�,��+.�:��.:�:�.�++.�.ia,�:�:�wx•..+t;i++t:��+++x�t:�3ai.a:�x�.xxxxt��a:�a�+++��x�i+a�.:�w:�:r+x++�.�.+++.++«�� CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: B12-0085 Address: 181 W MEADOW DR VAIL Owner: VAIL CLINIC INC Location: VAIL VALLEY MEDICAL CENTER ,.,.,,�.,.>..�..{..�...,.,...�,..�...............................�,...,.,,,.,,,>�....,,.,.,.,,,.,,,,.,,...,,.,...��.>....,.,,...,,....,.<..��.«.,.,.,....,.,,>�.,..,...,.��...,,.,.,,� Cond: CON0012524 If any use of Public Right of Way is need during construction, Contractor must apply for a Public Way Permit. canbination permit_012811 � -_: ` � ����� Y�! � ��,������.������x�.�x*,��.��.*,*����>��,#*���»*�<**������*�,*���,.*#**��,.��,****����*�*****.���**��,.,��.,�..�,�+�***����<�*�����***�����****���,��<*�� REQUIRED INSPECTIONS AND STATUSES Permit#: B12-0085 Address: 181 W MEADOW DR VAIL Owner: VAIL CLINIC INC Location: VAIL VALLEY MEDICAL CENTER ����*�****��***#*�**�**�****�*�******�*�**�****���******��****�*����******��*******�*�*******�*******��*��*�*����*********�***��****#**��*****�**�*** Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00310 MECH-Heating Item: 00320 MECH-Exhaust Hoods Item: 00330 MECH-Supply Air Item: 00340 MECH-Misc. Item: 00390 MECH-Final Item: 00190 ELEC-Final Item: 00090 BLDG-Final combination permit_012811 ***********************************************+******************************************** TOWN OF VAIL, COLORf1D0 Statement �*�**************************************�********************************�***************** Statement Number: R120000421 Amount: $6,443.89 05/07/201209:46 AM Payment Method: Check Init: WC Notation: Check 9307068889 Permit No: B12-0085 Type: COMBINATION BLDG PERMIT Parcel No: 2101-071-0101-3 Site Address: 181 W MEADOW DR VAIL Location: VAIL VALLEY MEDICAL CENTER Total Fees: $7,560.19 This Payment: $6,443.89 Total ALL Pmts: $7,560.19 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 202.45 MP 00100003111100 MECHANICAL PERMIT FEES 2,860. 00 PF 00100003112300 PLAN CHECK FEES 392 .44 UT 11000003106000 USE TAX 40 2, 979.00 WC 00100003112800 WILL CALL INSPECTION FEE 10.00 ----------------------------------------------------------------------------- Department of Community Development 75 South Frontage Road TOWN Of VAtL �� va�i, co $�ss� Tel: 970-479-2'!28 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: Project#: �Q�S �d,-� �a ��� (j,.;. �1��.�ta i,., 1.� (Number) (Street) (Suite#) DRB#: - �A- i � Building Permit#: ��o� - ���S Building/Complex Name: �/��t �t�`t�E,�, 1�Ec����( �,1�z. � Contractor Information �a�-rYl Lot#: Block# Subdivision: Business Name:_�t-1m�',t+[an.,/�cc�an,��a,� Sf�=v�:.i `.�.G Work Class: New(�j Addition �j Alteration Business Address: 77� �:Nc�(,E� ��, � City�SUr'Yl State: �'. Zip: �1�,37 TYPeof Building: ., Single-Family�j Duplex�j Multi-Family((�jj Contact Name: t F�� ��o�O�.� Commercial � Other�j Contact Phone: �'�10 � 3l� - O U.�3 �-- Work Typ�: lnterior� E;cterior� Both � Contact E-Mail: �(`�lobE2�: o /3i7�.Ir.F��SA Cr•�h'I I hereby acknowledge that I have read this application,filled out Valuation of in full the information required,completed an accurate plot plan, Work Included Plans Included Work and state that all the information as required is correct. I agree to Electrical �Yes �No Yes 4No �3 .�� comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to Mechanical �Yes �)No �Yes �No �a�l .`°' the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other Plumbing �Yes �jNo �Yes �No ordinances of the Town applicable thereto. i Building �Yes �No QYes �No X Value of all work being performed: $ �5� �'�• G 0 Owner/ er's Representative Signature (Required) (value based on IBC Section 109.3&IRC Section 108.3) Electrical Square Footage Applicant Information Detailed Scope and Location of Work: Applicant Name: �rnc�E c.lcl T� c 1���� i�►� 7u��c11 ApplicantPhone: NEw �,�c,e;;E� C��n�����.:a, ��'`u,� .���,�a� Applicant E-Mail: � � � � � ' A' /�. AlviC /�� /�E��G�itE�. Project Information l / P �_'���IEG �Cr��iE�' i�. %�41,c n�,�F� ��fchA+uG'4� Owner Name: v��w�. �;N�C T,vG „ � p / ' / �YN i C c',,.�'Eivl/�. IOC�1�,c�/ far.�!"SiG/E hf`l i�y^ Parcel#: �Jp/ -071 '0! -OI /� J J � (For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit l u,t�Cr� �va/�* � h�GE i 1 .�XiJ�'fi�/ E�:l.r�+n7Et'� www.eag lecou nty.us/patie) (use additional sheet if necessary) �ti 6 D�� /�Kt'.�1; For Office Use Only: � � �/7 � Fee Paid: Date Received: D U Received From: Cash Check # APR 0;� 2��2 CC: Visa/ MC �ast 4 CC# exp dete: ��;�_,, Auth # '.. _ ����1� �� ����..,..>�;'.U.' � 12-Mar-2012 ��V � ���� l ° ,� ,� ,� l �C� `.� � �� �� SP�' ss" '� CA N �Q 1� C�� r �� � _ _e __ __ ____ _ ._v_ _�___. � ` � �L ` �� l\` r�� __ -.�-, �, :-- `�. ;� .=.�. r _ � � '�. r � — f f �`� �, ' I ` � , // � �'�.:..�'� ti�.,,..�., ::-r . ` �.-..:. .,, _ `^ ✓„`.! ``�_ ,„;.:. w.�` i �-.:�-v I j ' _ :_ � � //�� �: �� 1� •' �,. '��'"`'�`^., ~ — '�' ` �/ r` -���` � y.. �" "": r�/ _ ..y . . tr� lS-6 l \`" � f ..' ,,_ ��, `•`� '�,, i \.v -�� . - �„ '�. /% - �-.:"/r .� �`;:�.. � � �.. �,A � ..r.�'/� ��" . .�: .,,�^--� ....�.' � ,..—�' ��-.. . w � � ��� I ! 4 1 � — # � — - - �_ � � � � -�; �'1 �� ;:� �I f�>� •-; f,,,� , , � �, — — - - - , � ,f� � ,rt� ,� {,' ^ � - _ � f� ���d t - C� . �',�� _. ., F , ,I .:� _ ./�1'�' ^.'{ .�t � l � � . _ . .� � � x._,i r e� fl''� _ ,A;E,f' ' -. I / I` , � '\' � � , � I '� �� ��� (32-(}�-�n.�-, HTP� CONDENSER GOIL PERFORMANG� n�ooEi c z �� � �� -��� ���.� f Same End Connections 1 Custo . �e�_, A c��� Co�l�.:soz .��b: Wf�lC Vaif -WCS099H -2 x 3 �ans �� V�� • INPUT DA Condenser Specificafions aperating Conditions Surface Type: K Air Volume: 84,100 CFNi Finned Height: 90 Inches Entering Air Temp: 95° F. � 300 ,,,�� Finned Len�th: 145.5 Inches Condensing Temp: 125° F. Rows Deep: 4 Entering Gas Temp: 155° F. �in�Per inch: 12 Suction Temp: 40° F. IVumber of Feeds: d4 Refriaerant: R-410A � Fin Thickness: 0.006 Inch Aititud�: 8200 Feet � Fin Material: Aiuminum Subcooler Specifications Number of Face�'ubes: 6 Number Feeds: 12 Number Passes: 2 Dropped Tubes: 0 Same End Connections CALCULATED DATA Condenser Performance Total Heat Rejection: 1,143,045 Btuh � Refrg Pressure Drop: 3.66 Psig Air Pressure Drop: 0.43 Inches Leaving Air Temp: 120.5° F. Face Velocity: 705 FPM Face Area: 90.93 Sq Ft Tubes in Face: 66 Passes: 6 J ��" �' Dropped Tubes: 0 1,��.����3 6"f"�-t,.H � 3d''F 3!� lnternai Coil Volume: 4.95 Cubic Ft. - toz.3 T�5 Subcooler Performance Co���c.-4-;�.s •, Liquid Temp In: 125° F. t-4vf �� �2� ,��� o p �S�� Liquid Temp Out: 114.2° F. ,,y,�t j s L-'��➢e� �..t� Y`$ ��� ,� � Capacity: 54,7'i8 Stuh Liquid Pressure Drop: 0.04 Psig . � � � � Unit Report For 40-ton Project: �Untitled13 02/09/2012 Pre ared B : 08:54AM Unit Information Accessories and Installed Options Tag Name:_____.._..............._......________.._._.......40-ton No Accessories or Installed Options selected Model Number:............__....._______....._.30MPA040 Condenser Model:_......_...........__.......____..09DPM095 Remote Condenser Accessories and Installed Options Compressor Type:...._......._._____......._.._....._ _Scroll Micro Channel(MCHX) Nameplate Voltage:........_______...............__..460-3-60 V-Ph-Hz Single Point Power,Terminal Block Quantity:. ----__.._ ---- ......._._.........__ -_................1 Standard Ambient Manufacturing Source:.............Charlotte,NC USA Standard Interrupt Refrigerant:__ ____.._......... __ ___..._.._........._. R410A Bronze Y Strainer(40 mesh, 3"NPT) Capacity Control Steps:_ _.........-------. --_ ----__...___.3 Minimum Capacity:... -....- ..........--- 33 % Chiller Shipping Weight:.__...._.._................_.___ 1032 Ib Chiller Operating Weight:____......................._____913 Ib Chiller Unit Length:___._____.----.-..---.------------......__55 in Chiller Unit Width: ----_._......__.._...-----_..----..._.._..32 in Chiller Unit Height:_-- _.......-.-------__------ - 63 in Condenser Shipping Weight:___...__............_._._1880 Ib Condenser Operating Weight:_.__._........._..._..1933 Ib Condenser Unit Length:_ ..........._...._._ . _..._151 in Condenser Unit Width: ..._...__.____.88 in Condenser Unit Height:...........__......................_.._.. ..73 in Warranty Information(Note:for US&Canada only) First Year-Parts Only(Standard) Ordering Information Part Number Descri tion Quanti 30MPA04060-00005 Packa ed Chiller 1 Base Unit Micro Channel MCHX Sin le Point Power Terminal Block Standard Ambient Standard Interru t 30MP-900--008 Bronze Y Strainer(40 mesh, 3"NPT) 1 Packaged Chiller Builder NACO 3.39e Page 11 of 19 F' I - ie d Wiring Diagram for 40 ton Project: �Untitled13 02/09/2012 Pre ared B : 08:54AM There is no Certified Drawing available for this tag � � Packaged Chiller Builder NACO 3.39e Page 13 of 19 .�, .. _ ...__._..._.__�._._�_... _ __ . __ _ . __ _ _ . _ _ . _ "�„ .nr Summary Performance Report For 40-ton Project: �Untitled13 02/09/2012 Pre ared B : 08:54AM ,�QUAS' N�P� ���� III , i ��� AquaSnap�" Remote Air Cooled Scroll Chiller �� ',, � �.� � �A� � � , x� :� �'f ' �� ���� T. ':&h Unit Information Tag Name:......_.________._........._.. ___ __40-ton Performance Information Model Number:__._......_._ ________30MPA040 Chiller Cooling Capacity:__._.__......................__.._31.4 Tons Condenser Model:...........__.______09DPM095 Chiller Compressor Power: 36.1 kW Quantity:_.__._......._.._____._._..._..........._...________1 Chiller A-Weighted Sound Pressure:_________.71 dbA Manufacturing Source:__Charlotte,NC USA Chiller A-Weighted Sound Power:..__._._.....___..86 dbA Refrigerant:__........._......._________..._........R410A Condenser Circuit Used: .._____...._........_...Circuit B Chiller Shipping Weight:_.__________ _.._1032 Ib Chiller Operating Weight:..............________973 Ib Combined Performance Information Chiller Unit Length:._.._______.._........._.._...__55 in Total Compressor and Fan Power:........__..........39.2 kW Chiller Unit Width:__.___......._....__.._____...__.. 32 in System Full Load Efficiency:_______________1.250 kW/Ton Chiller Unit Height: 63 in Condenser Shipping Weight:.......................1880 Ib Accessories and Installed Options Condenser Operating Weight: 1933 Ib No Accessories or Installed Options selected Condenser Unit Length: ....................__._._._151 in Condenser Unit Width:________....._.........._._._88 in Remote Condenser Accessories and Installed Options Condenser Unit Height:. ____________ .___.73 in Micro Channel(MCHX) Single Point Power,Terminal Block Evaporator Information Standard Ambient Fluid Type:___.__...._.___.__Propylene Glycol Standard Interrupt Brine Concentration:____._..._..... _...____40.0 % Bronze Y Strainer(40 mesh, 3"NPT) Fouling Factor:.______...__........._...._...__0.00010 (hr-sqft-F)/BTU Leaving Temperature:............._.......________36.0 °F Electrical Infortnation Entering Temperature:..............._...._________46.0 °F Note chiller and condenser require electrical connections Fluid Flow:.__.......... -- ___.........--.._... 81.4 gpm Pressure Drop:___...._...._.....________..............10.6 ft Electrical Electrical Chiller Condenser Remote Condenser Information Unit Volta e: 460-3-60 Altitude:..____________.............._______________8200 ft Connection T e: Sin le Point Sin le Point Number of Fans:......_______._.__......._._..._....._._6 Minimum Volta e: 414 Total Condenser Fan Air Flow:........._._......___0 CFM Maximum Volta e: 506 - Entering Air Temperature:_____.__..........._..95.0 °F MCA am s : 75.075 - independent Refrigerant Circuits:__ __ ___2 MOCP am s : 90 - Refrigerant Piping Equivalent Length:____ _50 ft ICF(amps): 196.2 — Discharge Line Loss:_____....__..........__...___0.1 °F Remote Condenser Performance Information Condenser Total Fan Power.._._..._.____.__3.12 kW A-Weighted Sound Pressure Level:...__..__.67 dbA A-Weighted Sound Power Level:__________99 dbA An uncoated Novation condenser coil was selected for this product. This is based on an installed location with postal code 81657 and a non-corrosive localized environment. Outside the scope of AHRI Standard 550/590-2003. Positive Displacement Units intended for use with glycol or other secondary coolant for freeze protection with a leaving chiller fluid UNIT OPERATING A 8 C D E F NO.OF WEIGHT (Ib) COMPRESSORS JONPA015 626 118�kg1 ���80 25.10 31.19 1152 mnl t63B ninl IB00 mm> 5.5/ 6.1� 18.50 30NPA020 6J5(2BB tgl »�60 25.t0 31.39 ���� ^�^�� ��6/�ml 1/70 mnl 2 11�7 mn1 1610 mml �7g7�� FIEID COXMECTI (U 1/E'N.0 30MP�030 722(321 Yyl >>.00 t6.00 )0.69 S.E7 11.17 17.95 U3d nin! 1660 mml [IBO�ml /l�9 mnl (tbt�ml (156 md 30NP�010 913 111�Yg) �I/S siYnl 165E mm) 1851 Siml 5.99 11.00 11.72 � , ���� JOMP�0�5 11� 1�2�Yg) I7 10 26.00 31.19 I151 m�l It19�ml (I50 en1 11131 11/2 anl 1660 mml 1651 mnl p�f � �OPTIONAL SOUND ENCLOSURE 18.12[17301--y 0/0,015 TON EMTRT i�p�� I�OMLT OPTIONAL SWND ENCLOSURE 32.12 Il16] 5[AOLIING CdIPRE550R (SEE TABLE 10R OT11 I OPiIOMAL SOIIMD--� MAAOUEC DISPLAT i_'-'-__'_'_e__i i__-'-_- -_ _ _-_-_ � . ENCLOSUAE \i-_______-_-_-_- � 1 � . � ' ' NON-fUSE � � � I I I I � DISCOMMECT I i � i (OPTIONAU � � i I ' I I � I . . � I � , 00 0 � � H � � a� a- a� � ONTROL BO% � � ACCESS DOOP � i CLC�RAXCE I I I • • I I I 36'f9111 � � � p � ENSUPE CIEARANCE � � I I I I COXTROI�PAXCLES I I �80 NDL � � � � � i , EMD OF UXIT � � ENCL0.SURE I • I � I I i3.05 I163t1 ' • f '-��-_ _-_'-_S_�__'_'"__'_� i 1/1'FPT 62.50 � �CCESS I � I � i [15881 I �M � � I I W � pT i i i APOR75 �N I COOLER I REIqTE COMDCNSEA ��«p I � � COMNEC710N � � � • � I I ° ° . I � � • , IIATEA COXMECTION i i � • � � F I • COOLEP � � tIN/OU11 I I 7' VICT,1UlIC 1015_0701 I 11R' YICT�UL1C1030-0/5) � I ' � � LIO. LIME � � • I ISM�TIOX YALYE i OUT 1•TS I i • i 111] � I I OUT I I i � ___.� ���_-'__ � • -_ ' _-_-_ _-_- ' _-_� i _ ___-'_._ -0.- _�D�' 1//'SAF � O �� � D E 10. IINE FLARE NfL1EF SOLENOID CONMECTION B i I � I Y�LYE FORII POCIIET 3.85 � [9!1 \ /.00 110t] ppppg� �q�rpp� pp� p�p MOUNTING NOL[S 9/16' MOBILITT AIT `MpUM71MG HOLES 9l1t' ISOlATOA�OPTIOMAL Si.30 (WXCELI OPTIONAL [132D1 t9.17 17�01 STD UMIT SS.00 STD UMIT 32.00 NOTES: n3s�i iei3� 1. Operating weight includes weight of water and refrigerant. orTio���souxo exaosupE s,.00����a� ��� P� � 2.�Denotes center of gravity. 3. Dimensions are shown in inches. Dimensions in [ ] are in millimeters. 4. Allow 36-in. (914 mm) clearance on control panel end, opposite control panel end and above the unit. All clearances must be in accordance with local codes. 5. --- Denotes accessory or factory-installed option. Fig.4-Dimensions-30MPA015-045 Units _..._................_.._._...................._...._.._.__...._ _.__..__........_....._..-- --......._._.- _........_............_......---.. OPERATING N0. OF UNIT WEIGHT (ibi A e C D E F G N � �pNPRES50RS 30MPMU15 680 (30B tgl ��'S7 18.50 21.B0 115�^^'� 5.51 6.// 18.50 5.51 8.11 IB.50 (170�m) l6)0 mml J0.20 II11 mml 116/mm) (I70 mml (1�1 mnl (161 mm) UTO�1 30NPM020 10�13�9 tgl �T67 mm� 2 CONNECTIOX�1/�1 I8.t0 ?5.10 18.61 t6 89 5.87 ti.t? 17.95 1/8'K.0 30MPM030 B62(391 Ygl ��R mml f6/0 mm1 R21 nm) [/t9 mm) (1/9 mni (282 mml U56 mml 30MP�0/0 1099 U99 tgl 16 60 25.�0 I0.96 5.87 11.I2 U72 mn) (638 mml 1786 mJ tM9 mm) (t82 nnl 1i.95 5.99 11.00 fiJ2 30NPt0/5 1190 [510 tg) �d.90 d/.90 30.22 ��56 mm1 115t mn� �t19 mml (150 mm) 3 ppN(p � � I1131 f/80 mml 1632 mm) (768 ml ENTR1 � �.0) OPTIONAL SOUND ENCLOSUAE IB.It 11230] ���z� OPTIOMAI SOUX 0�0.015 i0M [NCLOSIIRE OPTION�I SOUND SCROLIING CONPACSSOR �ONLY EMCLOSIIPC 32.1t f8161 _ _ _ _ _ _ ISEE TABLE f08 OTY) r- �N�ROUEC DISPLAY I . . I I-_-_-_ '_ _ '-'-__ -'_'_'-_-'-__ i i xOM�FUSE I i i DISCONMECi 1 : fOPTI0MAL1 � � - s � � s a s � � . , � I ONiAOL A01 � I � I I � � r' I ACCE53 DOOR I I i CtEAPANCE i � � 36'19fU I ENSUAE CLEAPANCE I VEA LOC�L CODES OPTIOMAL $WXO I I I I CONiROL P�XEL EMU OF UMIt ( i � ENCLOSURE � '� 6d 15 I . . . . . . . . � nseu I ! __'_' _ '_'_ IIP FPi _ � I ACCCSS •I -'-' -_-' - 6t.50 ... PIPIMG APEA ����� ft1XEB SI�E IN i P.T I hCCE55 � pp7 I OUf O PORiS �N � I � I . COM� I COOIEP COMD COOIEA COXD 13.99 U551 0 . o �I COOtEN WATER COXNECTIOM$ • • fINlOUTI C � I • COOICP � 2'VICT�UIIC f015-020� i OMD NATEA COMNECtI0N5 � I � � .I t tl2'VICTAULIC f030-0/51 IIM/OU1I • • 1.5'YttT�Ul1C/015-0207 OUI I 1.75 11/1 I t'VICTAULIC 1030-0/57 IN Wr� M __ _-_O _ _ _-_ _ _T_� _-_ _ _ __r-_-o D __T _____ t//' SAE � x fI�RE NEUEF i CONxECilON B E F08K POCKETS 3 BS I � 1.00 f1021 �� NOBILILT�K/i \ � �SOlAIOR-OP110NAL ��� �a PAn� �D NOUNIING NOlES 9116• [�NEEtt OPiIONAL ��UNTING MOIES 9/16' 52.30 113281 29.13 17/07 STD UNIT 55.00 f13971 STD UMIi R.00 18131 OPTIONAL SOUXU ENCIOSURE 57.00 I1//6] NOTES: ��� P�' � 1. Operating weight includes weight of water and refrigerant. 2. �Denotes center of gravity. 3. Dimensions are shown in inches. Dimensions in [ ] are in millimeters. 4. Allow 36-in. (914 mm) clearance on control panel end, opposite control panel end and above the unit. All clearances must be in accordance with local codes. 5.---Denotes accessory or factory-installed option. Fig.5-Dimensions-30MPW015-045 Units � � Summary Performance Report For 40-ton Project: -Untitled13 02/09/2012 Pre ared B : 08:54AM ' chillers in afree field and AHRI Standard 370 for remote condensers. ' i i Packaged Chiller Builder NACO 3.39e Page 15 of 19 `�,,,,' � Acoustic Summary For 40-ton Project: �Untitled13 02l09/2012 Pre ared B : 08:54AM Unit Parameters Tag Name: _. - - 40-ton �..�. , �,-_ ;�r—_____-+z r-.___—_-►: Model Number:__ . ........ 30MPA040 .� :, < Condenser Model: _........09DPM095 � .... CompressorType: _.....Scroll - ----� _ _ _.... Chiller Nameplate Voltage: __ ___ _460-3-60 V-Ph-Hz , Quantity: _ - _ ....._.......1 � . � ; Manufacturing Source..... ____Charlotte,NC USA _ � s �3 Refrigerant:- _.._............._ _...__.._......R410A �" , =:y; 1 -Height Above Ground 2-Horizontal Distance to Receiver 3-Receiver Height Above Ground Accessories and Installed Options No Accessories or Installed Options selected Remote Condenser Accessories and Installed Options Micro Channel(MCHX) Single Point Power,Terminal Block Standard Ambient Standard Interrupt Bronze Y Strainer(40 mesh, 3"NPT) Acoustic Information(Full Load) Octave Band Center Fre uenc , Hz 31 63 125 250 500 1k 2k 4k 8k Total Sound ressure at s ecified distance in a free field, d6 57 48 53 67 69 65 66 59 54 73 A-Wei hted Sound Pressure Level, dBA 17 22 37 58 66 65 67 60 53 71 Sound Power at Chiller Acoustic Center, dB 71 62 67 81 83 79 80 73 68 87 A-Weighted Sound Power, dBA 31 36 51 72 80 79 81 74 67 86 Remote Condenser Acoustic Information(Full Load) Octave Band Center Fre uenc ,Hz 31 63 125 250 500 1 k 2k 4k 8k Total Sound ressure at s ecified distance in a free field, d6 49 69 66 65 65 62 58 56 52 73 A-Wei hted Sound Pressure Level,dBA 17 22 50 56 62 62 59 57 51 67 Sound Power at Condenser Acoustic Center dB 81 101 98 97 97 94 90 88 85 105 A-Weighted Sound Power, dBA 42 75 82 88 94 94 91 89 84 99 Chiller Condenser 1 -Hei ht Above Ground, Ft 0 0 2-Horizontal Distance to Receiver Ft 3 50 3-Receiver Height Above Ground, Ft 0 0 Notes Estimated Sound Power levels-dB re: 1 picowatt Estimated Sound Pressure levels-dB re: 20 micropascal Estimated sound levels given above are assumed to originate at the acoustic center of the chiller. Sound pressure level data used to develop this program was determined in accordance with AHRI Standard 575 for 30MPA indoor chillers in a free field and ANSI/AHRI Standard 370 for remote condensers. Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical Packaged Chiller Builder NACO 3.39e Page 16 of 19 . � � Acoustic Summary For 40-ton Project: -Untitled13 02/09/2012 Pre ared B : 08:54AM estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Chiller Builder NACO 3.39e Page 17 of 19 . � � Detailed Performance Summary For 40-ton Project: —Untitled13 02/09/2012 Pre ared B : 08:54AM Unit Information Tag Name:...- --_............. ..._- -_.....40-ton Model Number. .....__.........._.._.30MPA040 Condenser Model:._____...._...................___09DPM095 Compressor Type: ---...................- - - - -- -Scroll Nameplate Voltage:.____ _._................. ___460-3-60 V-Ph-Hz Quantity: - ..........._ - ____..._.......- -_1 Manufacturing Source: Charlotte,NC USA Refrigerant:_-......._---- ----_......_.........._- ---- -R410A Capacity Control Steps_.........------------- ----.._.._....3 Minimum Capacity:_.......... -----.----------......_.........33.0 % Chiller Shipping Weight:______......_.........._.........1032 Ib Chiller Operating Weight:_..___.__......_....._............_913 Ib Chiller Unit Length: _...__..........__.............55 in Chiller Unit Width:_-- --._. ._.................--- - - 32 in Chiller Unit Height:......... -_--.--....................--.63 in Condenser Shipping Weight:_____..._.___.__......1880 Ib Condenser Operating Weight:_.................._...._..1933 Ib Condenser Unit Length:......__.....____..______..._.151 in Condenser Unit Width:- _ ._........__...--.. . _. -----88 in Condenser Unit Height:.._______________._ ._... ....73 in Minimum Outdoor Operating Temp: (See Product Data.) Performance Information Cooling Capacity: - -_..._........- ... - 37.4 Tons Total Compressor Power:___......__............_...____36.1 kW Total Fan Motor Power:_____________................. 3.12 kW Total Unit Power(without pump):...__.._..._____39.2 kW System Efficiency(without pump): 9.60 EER Chiller A-Weighted Sound Pressure:.....__._____71 dbA Chiller A-Weighted Sound Power:_____._............_86 dbA Condenser Circuit Used:_______._....._......_Circuit B Evaporator Information Fluid Type: _...... ....... Propylene Glycol Brine Concentration:...__...-- -- _-- ---___.. .40.0 % Fouling Factor:_____._......_............ 0.00010 (hr-sqft-F)/BTU Leaving Temperature:............._-_--._.---.- - - __36.0 °F Entering Temperature:...__..._..._.._..._........_.__.......46.0 °F Fluid Flow:...._ _.............. . -....... - - 81.4 gpm Pressure Drop: __.._............._... 10.6 ft R mote enser Information Altitude:...__ - -_-__ -- - - 8200 ft Number of Fans:... -- -.. _ _........ .-- 6 Total Condenser Fan Air F ._... ...._........_..............0 CFM Entering Air Temper e:._._...._._ ._._ _____95.0 °F Independent Re � erant Circuits:.__..............._. ......2 Refrigerant ' ing Equivalent Length:_____.___ ft Disch Line Loss:---- - .........._..............__ ._.0.1 ° Remote enser Performance InfoRnation Condenser Tota o �_.___ ----... . A-Weighteri-�oun8 ress :_ ________.._67 dbA —,4-11Veighted Sound Power Level:_.___ ___99 dbA Combined PerfoRnance Information Total Compressor and Fan Power:.._..__._........39.2 kW System Full Load Efficiency:___._____________1.250 kWlTon E lectri ca I I nfo rm ati o n Packaged Chiller Builder NACO 3.39e Page 18 of 19 • � � Detailed Performance Summary For 40-ton Project: —Untitledl3 02/09/2012 Pre ared B : 08:54AM Note chiller and condenser require electrical connections Electrical Electrical Chiller Condenser Unit Volta e: 460-3-60 Connection T e: Sin le Point Sin le Point Minimum Volta e: 414 - Maximum Volta e: 506 - MCA am s : 75.075 - MOCP am s : 90 - ICF(amps): 196.2 -- Integrated Pump Information No Pump Selected Accessories and Installed Options No Accessories or Installed Options selected Remote Condenser Accessories and Installed Options Micro Channel(MCHX) Single Point Power,Terminal Block Standard Ambient Standard Interrupt Bronze Y Strainer(40 mesh, 3"NPT) An uncoated Novation condenser coil was selected for this product. This is based on an installed location with postal code 81657 and a non-corrosive localized environment. Outside the scope of AHRI Standard 550/590-2003. Positive Displacement Units intended for use with glycol or other secondary coolant for freeze protection with a leaving chiller fluid temperature above 32°F[0°C]are certified when tested with water at AHRI Standard Rating Conditions. Sound pressure level data used to develop this program was determined in accordance with AHRI Standard 575 for 30MPA indoor chillers in a free field and ANSI/AHRI Standard 370 for remote condensers. Packaged Chiller Builder NACO 3.39e Page 19 of 19 ' � � Unit Report For 45-ton Project: —Untitled13 02/09/2012 Pre ared B : 08:54AM Unit Information Accessories and Installed Options Tag Name:.. __ ___ _____45-ton No Accessories or Installed Options selected Model Number._.____ __ ______ ____30MPA045 Condenser Model:.. ..__........._______ 09DPM095 Remote Condenser Accessories and Installed Options Compressor Type:......_...._..__. __ _ .Scroll Micro Channel(MCHX) Nameplate Voltage:......... ___ __ __ _ 460-3-60 V-Ph-Hz Single Point Power,Terminal Block Quantity: _.. __9 Low Ambient Manufacturing Source:..._. __Charlotte,NC USA Standard Interrupt Refrigerant:. ._ - _.......... _.R410A Capacity Control Steps: __ - --_ _-_ _ . _ 3 Minimum Capacity: ___ __ ° __.....- ... -.. 33 /o Chiller Shipping Weight:______________...._._ 1054 Ib Chiller Operating Weight:..._................_.........._ __934 Ib Chiller Unit Length:...... ._...----- --------------- _ _ 55 in Chiller Unit Width: _.___ 32 in Chiller Unit Height: ___._ _ ___.___ 63 in Condenser Shipping Weight:......._.............. .._..1880 Ib Condenser Operating Weight:._______.....__. 1933 Ib Condenser Unit Length:______.........._....._....._._ 151 in Condenser Unit Width:_ ___. . __ -.__-__.-- . 88 in Condenser Unit Height:______.........................._.__ _73 in Warranty Information(Note:for US&Canada only) First Year-Parts Only(Standard) Ordering Information Part Number Descri tion Quanti 30MPA04560-00005 Packa ed Chiller 1 Base Unit Micro Channel MCHX Sin le Point Power,Terminal Block Low Ambient Standard Interrupt Packaged Chiller Builder NACO 3.39e Page 1 of 19 Certified Drawing for 45-ton Project: -Untitled13 02/09/2012 Pre ared B : 08:54AM OPERATING NO.OF uNlt[o r.o.eo�aae s oocnrwr�s�x�rwv�xn a uxxico coavonenp I1N I T WE IGHT I I b 1 A B C D E F � iho is ouirenm uro��e urn�ss camnaw reer i�a '�"i'iro04casinmeo�n�wss�a W%�.��rs COMPRESSORS i[[xNO�o67[s s�auusc.M� ow.e�n iu�wr e�ws"na�o o�m�o uinour uRnie� 30MDA015 676 ctB1�gl �1.80 15.10 31./9 CARRIFA �zei �oevan�rid����irrc��oris�ir �«<n��c[a rowii�c� 1/52 mml 1638 mm) 1800 mnl 5.51 6.11 1E.50 17,60 15,20 37.79 ����^�"� �Ifi/mml 1/70 mm) 30NPA010 615 1188 lgl I117 mml �610 mml 1797 mml 2 �IELU[ONN([i10N I/1 7/8'X.0 30YP1030 722 1721 Ygl >>�00 26,00 30.69 5.07 11.11 17.95 1132 mml f660 mml 1780 mml 1119 mml 1282 mml 1156 mm) 3�NPA0/0 913 Id1/Igl >>�50 25.90 33.50 11/5 mml (656 mml (851 mml 5 99 11.00 11.72 1.16 IONPA0/5 97/1d7/Ygl I7./0 76.00 33./9 1152 mc) 1219 mm) I/50 mml � � 11171 1//2 m�l 1660 mml (B51 u POA'fR � � OPi10NAL SOUND ENCLOSUAE/8./2 112)O] a�0,0/5 TOM EN7RM /.03 [10t] �ONLi OYiIONAt SOUND fNClOSURE 32.17[8161 SCAOLLING COMPAESSOA ISEE iABI[fOR OiYI � NAAOUE[A]SPtAI ,. .._.__ . _- - _. . OPi]OMAL SWND--� ..-. .... .. .. ..___._. _ _._.'__. . -___ . .._.... __ . _ ._.._.__. ... ENCLOSURf \ a _ �, � - ° NON-FUSE � DIS[ONNECi IOViI0NAl1 e�e � o o� a a em � ONiROL BOk ACCE55 DOOR CLEARANCf 36'191/1 p ENSItAE[LEAAAMCE PEN LOCAL CODFS OP710NA1 CONiROL PANEI SOUNO Q ENO OF UNIi EN[LOSURE • 65.05 116521 . . . . . . .. - __ . . _ .. . _-_____ . .. . O 1//•fPi �� 67 50 ACCC55 � [15881 IN P.i AttESS IN PONiS COOLER R[MOIE CONDEXSER COOI[R '. CONN[CiION • o � . '�AiFR CONNEC7ION5 �O F • � � IIN/ouil o 0 COOLFR 2'VI[i,1ULlC 1015-0701 7 1/7'VICiAUIIC 1030-0/51 � LIO. LINE OUi 1,75 ISOLAIION VAIVE [d/] OUT :. .. .O ._�. . ____...... � 0 . . � . _se•.o-. __ o •�e .a Q • . __- .. . __p..� �. . ... O O I//'SAE a O • O O D E LIO. lIN[ FIAAE REII[F SOlEN07� CONN[C710N e i x I YALVE FORN POCNE75 S.BS \ A OPPOSITE COAfTROL PANEL END MOUN7ING HOICS 9/16' MOAIL981 Ali `MOUNiING NOlFS 9/16' ISOlAiON!OPit70N�L 52 30 �YINCELI OP7IONAL 113P81 79.13 17d0] SiD uNli 55.00 S7D uNli 32.00 NOiES�. f7391> I813] 1.OPIRATING WEIGN7 INCLUD[S WLIGxI 01 WA1EA AND AEFRIG[RAN7. OP7IOXAl SOUND ENCLOSURF 51.00 IId/81 CONTROL PANEL END 2. !9 D[NO7C5 CEN7FA Of GAAVIir. 3 U7NENSIONS IX f )ARE IN MIt�IM(�EAS AND WC1GNiS IN( 1 AAE IN MILOGAAMS 1.ALLOYI 36'191/)CICARANGE ON CONiAOI PANCI ENU,OPPOSIiE CONiROL PANCL EMU AND ABOVC TNC uN1T AND IN ACCOPDANCC WI1N LOCAI COOE. 5. �ENOiES ACCESSOAI OR FACiONY INSiALLEO OPi]ON. UA1[ SUP[IC[O[3 p�y 02/03/10 30MPA O15 045 UNIT ASSY 30MP555556 � 3 Packaged Chiller Builder NACO 3.39e Page 2 of 19 Field Wiring Diagram for 45-ton Project: �Untitled13 02/09/2012 Pre ared B : 08:54AM XOr[5�, CIR IAN ifAMINAI BLO[A POMEN ENiP1 I.fA(lOA1 IIIRING IS IX�CCORDINCE NIIM Ul 1995 SIANUAAOS.fI[LD YDDIlICAIIqIS CONTROL � OC ADDI110X3 MU51 9f 1M COMPLI�XCE Ylix AtL�PVLICABLE C00[5. �. 1.AlL IINIiS OA IqpUL[S x,1VE SINGI[POIXi PAIMARi PO�EP COMNEC1fOM.MAIX P4M[R YU51 B(SUPPII[D fRq1�fl[LD OA fAC10Ai SUPPIIED DIS[OMNECi. J.NIRING fpll MAIX fl[L�SUPVif NUSt B[PAtfD 1%.USF fOPY[R COMDIICIOAS OMLY. �Q'$-0� e ;M�COM^X�6�IP[SI!(A1X6E f0A 1[RNIX.1l 9lOClt IS 11 ANG(AYERIC�X IIIAE 4AGE1 �Z �� 3OMP TYPICAL CONNELTION �6MD �. IX[dI1XG/IA[SIi[FOR NON-fUi[D DISCOMNFCI WIiM MC1 UP 10 J!AYPS IS 11 IO 6 AMG,lOP MC�GREAt[A 1x�N SE�MPS IS!10 1�11G y 1.REf[A 10 f[A11fIEU DIN[NSIONAL DP1wIN65 fqV CCACi LIX,1110NS Ot 1N[NAIX POA[A AND C�NiAOL POwER ENtAAMC[LOC�110X5. � 5.J MP[A 1EANIMAlS 2,IMD 1 IO6fixIA AXO 1[PNIXALS�AXD/IOGEix[P f011 SIMGL[ YM11 pPCRI.110M 2d VOLi 6.I�l uX113 P,11[D!OA xlGx SxORi ClaCUI�IX1EPPUPi CIPA91LIi�MU51 BF 1AOi[CtED FIEL D uSING fY5f5. SuPPLIED iESt Mo: POWE R - i][LUIq[R�IRIXG CIA A Clk A - fAfiORY�IMS��I�[G�AIII�Mb FAN GAN CONTROL CONTROL 09DP035-130 a ��E�o Pa�. :� 7gp lil��� 30MP TYPICAL CONNECTION 4� E%TERNALLY SOURCED POWER uscwafcT�cH c�r , SEE NOTE 5 ^°«��� '�, � � isc�norz ui z�voir z,voir TERMINAL BLOCK FIEL� FIELD SUPPLIED SUPPl1ED POWCfl POWER MOX�fuSEO DISCOMX[Ci POMFR fXiR1 IIN1T 1 �N]T 2 i r � OR OA m m CIA A C1F B �FANA �FAN ZdV 2dV CONMON CONTROL CONiROL �io� � i � a � s s 09DP065-130 ' m o m o m ❑� � , 30HXA TYPICAL CONNECTION �,...�r SEE NOTE 5 CRBII i FAN , � -�- -� il[LO POIYFP SYPPLI �� CIP A FAN �N'ECT/HUNGI CWCIAT PP07FL710N f9i I�BC tSEE MOIf IJI NON-FUSED DISCONNECT Packaged Chiller Builder NACO 3.39e Page 4 of 19 I � . Summary PerFormance Report For 45-ton Project: �Untitled13 02/09/2012 Pre ared B : 08:54AM ��U�11�AP� �,-��,. , > ��� AquaSnap�^ Remote Air Cooled Scroll Chiller � � � �. �u � � �r � � �� � � �.� � � �. ���� Unit Information Tag Name:__._... _____.._...._.._______......45-ton Performance Information Model Number:__..___.._____ ___._.30MPA045 Chiller Cooling Capacity:_______..__....................._35.5 Tons Condenser Model:...___ __.. _... .09DPM095 Chiller Compressor Power:...__.........................._..43.5 kW Quantity: .._.. __ _____....... ____ __._._.___1 Chiller A-Weighted Sound Pressure:_ ____73 dbA Manufacturing Source:...Charlotte,NC USA Chiller A-Weighted Sound Power:........_.________87 dbA Refrigerant:____......... _____ ._.._.._. ___R410A Condenser Circuit Used:_____ ____._......_Circuit A Chiller Shipping Weight:......._._._______..1054 Ib Chiller Operating Weight:___..........._.....__934 Ib Combined Performance Information Chiller Unit Length: ______.____55 in Total Compressor and Fan Power:___.__.....__46.7 kW Chiller Unit Width:...._.....__.....__......_................_32 in System Full Load Efficiency:..._..._.__..... ._...._1.313 kW/Ton Chiller Unit Height: . 63 in Condenser Shipping Weight:...............__._1880 Ib Accessories and Installed Options Condenser Operating Weight:__...........___1933 Ib No Accessories or Installed Options selected Condenser Unit Length:...._______.................151 in , Condenser Unit Width:._.....____ ____.___......88 in Remote Condenser Accessories and Installed Options Condenser Unit Height:.............. . _. ..73 in Micro Channel(MCHX) Single Point Power,Terminal Block Evaporator Information Low Ambient Fluid Type:.____ ..__..._....___Propylene Glycol Standard Interrupt Brine Concentration:.........._..______................40.0 % Fouling Factor:..._ ___.._.._....._....__ __0.00010 (hr-sqft-F)/BTU Electrical Information Leaving Temperature:..______............._____36.0 °F Note chiller and condenser require electrical connections Entering Temperature:...._..______........_.........46.0 °F Fluid Flow:.._.._._ ___....__....._...._____._._.......92.2 gpm Electrical Electrical Pressure Drop:.___ _______...____________.72.6 ft Chiller Condenser Unit Volta e: 460-3-60 460-3-60 ote Condenser Infortnation Connection T e: Sin le Point Sin le Point Altitu : ___ ____ 0 ft - -- -.......-. Minimum Volta e: 414 414 Number o s:___._...._. _______. ..........._ _6 Maximum Volta e: 506 506 Total Condenser Air FI .______...67500 CFM MCA am s : 87.425 20.6 Entering Air Tempera ________......_...95.0 °F MOCP am s : 110 20 Independent Refri ant Cir ' •.___............._2 ICF(amps): 232.8 -- Refrigerant Pi � g Equivalent Leng :. ....50 ft � Dischar ne Loss:-- - ...._..._._. - - --__.. °F R�me ondenser Performance Informa ' Condenser an Power:_. 3.12 kW A-Weighted Sound r evel:.. ___67 dbA A-Weighted d Power Level:_____ __99 dbA An u ated Novation condenser coil was selected for this product. This is based on an installed location with postal code 81657 and a non-corrosive localized environment. Outside the scope of AHRI Standard 550/590-2003. Positive Displacement Units intended for use with glycol or other secondary coolant for freeze protection with a leaving chiller fluid � . , i Summary Performance Report For 45-ton I Project: -Untitled13 02/09/2012 Pre ared B : 08:54AM chillers in afree field and AHRI Standard 370 for remote condensers. Packaged Chiller Builder NACO 3.39e Page 6 of 19 • • Acoustic Summary For 45-ton Project: —Untitled13 02/09/2012 Pre ared B : 08:54AM Unit Parameters Tag Name.... _. __ __.. 45-ton � �� - ----,2)-_...___---:� i Model Number:._ __. ._ _._.. 30MPA045 .��-�'���-�' �4---- �'� � � ' Condenser Model: 09DPM095 �� Compressor Type: _ _ ___Scroll , - --- Chiller Nameplate Voltage _ 460-3-60 V-Ph-Hz , 4 ° Condenser Nameplate Voltage:.. ____ 460-3-60 V-Ph-Hz = � ' Quantity: - . ..- - 1 . r -- -__.. _ . . Manufacturing Source:._______.__.....Charlotte,NC USA � � i 3 Refrigerant:__....... --.........--- __..._.._. R410A ---- ��; 1 -Height Above Ground 2-Horizontal Distance to Receiver 3-Receiver Height Above Ground Accessories and Installed Options No Accessories or Installed Options selected Remote Condenser Accessories and Installed Options Micro Channel(MCHX) Single Point Power, Terminal Block Low Ambient Standard Interrupt Acoustic Information(Full Load) Octave Band Center Frequenc , Hz 31 63 125 250 500 1k 2k 4k 8k Total Sound ressure at s ecified distance in a free field, dB 57 48 53 64 69 68 67 60 54 74 A-Wei hted Sound Pressure Level dBA 17 22 37 56 66 68 68 61 53 73 Sound Power at Chiller Acoustic Center, d6 71 62 67 78 84 82 81 74 68 88 A-Wei hted Sound Power, dBA 31 36 51 70 80 82 82 75 67 87 Remote Condenser Acoustic Information(Full Load) Octave Band Center Frequenc , Hz 31 63 125 250 500 1k 2k 4k 8k Total Sound ressure at s ecified distance in a free field, dB 49 69 66 65 65 62 58 56 52 73 A-Wei hted Sound Pressure Level dBA 17 22 50 56 62 62 59 57 51 67 Sound Power at Condenser Acoustic Center, d6 81 101 98 97 97 94 90 88 85 105 A-Weighted Sound Power, dBA 42 75 82 88 94 94 91 89 84 99 Chiller Condenser 1 -Hei ht Above Ground, Ft 0 0 2-Horizontal Distance to Receiver, Ft 3 50 3-Receiver Hei ht Above Ground, Ft 0 0 Notes Estimated Sound Power levels-dB re: 1 picowatt Estimated Sound Pressure levels-d6 re: 20 micropascal Estimated sound levels given above are assumed to originate at the acoustic center of the chiller. Sound pressure level data used to develop this program was determined in accordance with AHRI Standard 575 for 30MPA indoor chillers in a free field and ANSI/AHRI Standard 370 for remote condensers. Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real worid acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be Packaged Chiller Builder NACO 3.39e Page 7 of 19 � , � • Acoustic Summary For 45-ton Project: �Untitled13 02/09/2012 Pre ared B : 08:54AM appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. i i Packaged Chiller Builder NACO 3.39e Page 8 of 19 • • • Detailed Performance Summary For 45-ton Project: �Untitled13 02/09/2012 Pre ared B : 08:54AM Unit Information Tag Name:.. -- _.... _ __.. 45-ton Model Number: _.............._____30MPA045 Condenser Model:.____._................_._....._.09DPM095 Compressor Type:_......__----------------- ----.........._--Scroll Nameplate Voltage:..._______.......________..460-3-60 V-Ph-Hz Quantity:_...._...-- .............. - -_........._ __...._ 1 Manufacturing Source: Charlotte,NC USA Refrigerant:........... ....__._....--- - -..__.. R410A Capacity Control Steps:............----------...._. - 3 Minimum Capacity: --.._..-----_....----...----- _..33.0 % Chiller Shipping Weight: _1054 Ib Chiller Operating Weight:..._..__......................____934 Ib Chiller Unit Length: ___ ------------------------.....__55 in Chiller Unit Width: -- __.. . -------...__...-- - -32 in Chiller Unit Height:__--- _. -.---------......-------63 in Condenser Shipping Weight:........____........_.......1880 Ib Condenser Operating Weight:................_......_....1933 Ib Condenser Unit Length:___............__.__.._.............. _151 in , Condenser Unit Width:_............. __ ......_...__.. --_88 in ' Condenser Unit Height:.._...._ ___..._._........._._.____.73 in Minimum Outdoor Operating Temp: (See Product Data.) Performance Information I Cooling Capacity: ---......._. - ----........-_-- -----35.5 Tons Total Compressor Power.___....._.._._____.___ ....43.5 kW Total Fan Motor Power:__......._.____..................._ 3.12 kW Total Unit Power(without pump):_._____......__46.7 kW System Efficiency(without pump):_....._.._____9.14 EER Chiller A-Weighted Sound Pressure:_______._....73 dbA Chiller A-Weighted Sound Power:_.............______87 dbA Condenser Circuit Used:____.._....... ____Circuit A Evaporator Information Fluid Type: _ ........_ _-- ..___.....---PropyleneGlycol BrineConcentration:-_-___............. ......__--...... 40.0 % Fouling Factor:_..._._-.---.-_-_.._.....___ _-----.0.00010 (hr-sqft-F)/BTU Leaving Temperature:...______............._..______.....36.0 °F Entering Temperature: ..._....._...._.......____46.0 °F Fluid Flow:..... . -...._- ....__ -- -.... - -_..92.2 gpm Pressure Drop:.... --........ --- - ...._....__._12.6 ft Remote nser Information Altitude:.. __._...__-- -......8200 ft Number of Fans:...._- - _..... - - ---__ Total Condenser Fan Air Flo ..._ ____.__... 7500 CFM Entering Air Temper ..___.... ._.._...._ ___ _95.0 °F Independ ngerant Circuits:.........._____ ___2 � erant Piping Equivalent Length:._...._...._ _ 0 ft Discharge Line Loss:...... 0.2 ° Remote ser Performance for�rativtt Condenser Total r:__........__3.12 kW A-Weig und Pressure.___.. _..__67 dbA ighted Sound Power Level:_____.._.... bA Combined PerFormance Information Total Compressor and Fan Power.______.....46.7 kW System Full Load Efficiency:__________......_1.313 kW/Ton Electrical I nformation Packaged Chiller Builder NACO 3.39e Page 9 of 19 y ' • � e t� Detailed Performance Summary For 45-ton Project: �Untitled13 02/09/2012 Pre ared B : 08:54AM Note chiller and condenser require electrical connections Electrical E�ctrical � Chiller Co enser% Unit Volta e: 460-3-60 460�3-60/ Connection T e: Sin le Point Sin I P nt Minimum Volta e: 414 41 Maximum Volta e: 506 50 MCA am s : 87.425 20 , MOCP am s : 110 I, ICF(amps): 232.8 ' I Integrated Pump Information I No Pump Selected Accessories and Installed Options No Accessories or Installed Options selected Remote Condenser Accessories and Installed Options Micro Channel(MCHX) Single Point Power,Terminal Block Low Ambient Standard Interrupt An uncoated Novation condenser coil was selected for this product. This is based on an installed location with postal code 81657 and a non-corrosive localized environment. Outside the scope of AHRI Standard 550/590-2003. Positive Displacement Units intended for use with glycol or other secondary coolant for freeze protection with a leaving chiller fluid temperature above 32°F[0°C�are certified when tested with water at AHRI Standard Rating Conditions. Sound pressure level data used to develop this program was determined in accordance with AHRI Standard 575 for 30MPA indoor chillers in a free field and ANSI/AHRI Standard 370 for remote condensers. Packaged Chiller Builder NACO 3.39e Page 10 of 19 `� � _ . ` \� � 02-11-2013 Inspection Request Reporting — Page 4 2" lZ 4:08 pm V�, CO - CitTpf � � � `� Requested Inspect Date: Tuesday February 12 2013 Site Address: 181 W IN�ADOW DR�AIL VAIL VALLEY MEDICAL CENTER A/P/D Information Activity: 612-0085 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: VAIL CLINIC INC Contractor: AMERICAN MECHANICAL SERVICES Phone: 877-637-7397 Description: REMOVE OLD TSI CHILLER AND INSTALL NEW CARRIER CHILLERS. MODIFY ELECTRICAL AND MECHANICAL AS REQUIRED. CHILLER LOCATED IN BASEMENT MECHANICAL ROOM,CONDENSER LOCATED OUTSIDE BEHIND CONCRETE WALL. THERE IS EXISTING EQUIPMENT IN BOTH AREAS. Reauested Insaection(s) Item: 90 BLDG-Final Requested Time: 03:00 PM Requestor: AMERICAN�v1ECHANICAL SERVICES Phone: 877-637-7397 -or- 303-806- � 7364 Comments: 3 - 4 Assigned To: PIG N Entered By: JMONDRAGON K Actiorr:� -, Time Exp: 1` Item: 19H ELEC-Final Requested Time: 02:30 PM Requestor: AMERICAN ECHANICAL SERVICES Phone: 877-637-7397 -or- 303-806- Comments: 376-0423 7364 Assigned To: JM A ON Entered By: JMONDRAGON K Action: Time Exp: Item: 390 MECH-Final Requested Time: 02:00 PM Requestor: AMERICAN MECHANICAL SERVICES Phone: 877-637-7397 -or- 303-806- 7364 Comments: 37 -0 Assigned To: J N Entered By: JMONDRAGON K Action: Time Exp: �/ I� U ` � I � Inspection Historv Item: 120 ELEC-Rough Item: 200 MECH-Rough "Approved*' 12/07/12� Inspector: Martin Action: AP APPROVED Comment: Item: 310 MECH-Heating i Item: 320 MECH-Exhaust Hoods Item: 330 MECH-Supply Air Item: 340 MECH-Misc. Item: 390 MECH-Final Item: 190 ELEC-Final Item: 90 BLDG-Final REPT131 Run Id: 14641