HomeMy WebLinkAboutB12-0029 Plans Approved East MechanicalNOM. TONS TOTAL CAP(MBH)SENSIBLE CAP(MBH)COMPR. TYPE SEER REFRIG. TYPE AMB. TEMP MCAFUSEL(IN)H(IN)D(IN CU-1CARRIER 38HDR048LAUNDRY 4TH FLOOR MECH. SPACE 4.047.547.5SCROLL14.0410A8517.92572 dBA454317284LOW AMBIENT OPERATION, WALL MOUNTING KIT 208 / 3 / 60 AIR COOLED CONDENSING UNIT SCHEDULE UNIT TAG MANUFACTURER & MODEL NO.COMPRESSOR DATAELECTRICAL DATA V / PH / Hz OR EQUIVALENT REMARKS OPER. WT. (LBS)DIMENSIONS SERVICELOCATION MAX SOUND LEVEL CAP (BTU/LF)GPM EWT (°F)LWT (°F)WPD (FT)MOUNTING HEIGHT (IN. AFF)HEIGHTWIDTH BBSTERLING - CLCU75SEE PLANSSEE PLANS2 x 2505201.0180160-1 7/89 1/83 3/8 COORDINATE THE ENCLOSURE FOR EACH CONDO TO MATCH THE EXISTING ENCLOSURES THAT ARE REMOVED. COORDINATE ALL COMMON AREA ENCLOSURES WITH THE ARCHITECT.LOCATION ELEMENT SIZE (INxIN)FINS PER FOOT HEATING DATA SERVICE HYDRONIC BASEBOARD HEATER SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.COVER DATA REMARKS CAPACITY (MBH)GPMEWT (°F)LWT (°F)PD (FT)HPL(IN)H(IN)D(IN)CUH-1STERLING STAIR TOWER ASTAIR TOWER A1858.50.51801600.02 1/1535259.592 CUH-2STERLING STAIR TOWER BSTAIR TOWER B1858.50.51801600.02 1/1535259.592 CUH-3STERLING STAIR TOWER CSTAIR TOWER C1858.50.51801600.02 1/1535259.592 CUH-4STERLING STAIR TOWER DSTAIR TOWER D1858.50.51801600.02 1/1535259.592 115 / 1 / 60 ELECTRICAL DATA UNIT TAG MANUFACTURER & MODEL NO.LOCATION HEATING COIL DATA CFM V / PH / Hz SERVICE 115 / 1 / 60 CABINET HEATER SCHEDULE OR EQUIVALENT 115 / 1 / 60 115 / 1 / 60 OPER. WT. (LBS)REMARKS DIMENSIONS TYPEKWV / PH / HzMCAW (IN.)H (IN.)D (IN.)PTAC-1AMANA PTH123E15 ELEVATOR EQUIPMENT ROOM SEE PLANS28212,000ELEC.1.5208 / 1 / 6014421622153 FLUSH MOUNTED ARCHITECTURAL LOUVER, CONFIRM FINISH WITH ARCHITECT ELECTRICAL REMARKS LOCATIONCFM NOMINAL COOLING CAP. (BTU/H)HEATING DATA OR EQUIVALENT PACKAGED TERMINAL A/C UNIT SCHEDULE WEIGHT (LBS)SERVICE DIMENSIONS UNIT TAG MANUFACTURER & MODEL NO.SENSIBLETOTALEDB (°F)EWB (°F)LDB (°F)LWB (°F)EDB (°F)LDB (°F)EWT (°F)LWT (°F)GPMPD (FT)MCAL(IN)H(IN)W(IN)FC-1CARRIER 39S05LAUNDRYLAUNDRY1,9502000.5139.952.580.062.055.651.950.470.0100.2180.0160.02.00.203.9422245447.0 PREMIUM EFFICIENCY MOTOR, 1 INCH CABINET INSULATION, VIBRATION ISOLATORS, FLEXIBLE DUCT CONNECTIONS OPER. WT. (LBS)REMARKS UNIT TAG MANUFACTURER & MODEL NO.SUPPLY FAN HP DIMENSIONS SERVICE CAPACITY (MBH)TOTAL MBH AIR SIDE AIR SIDE WATER SIDE ELECTRICAL DATA FAN COIL UNIT SCHEDULE OR EQUIVALENT V / PH / Hz 208 / 3 / 60 HEATING COIL DATA DX COOLING COIL DATA LOCATION TOTAL CFM O.A. CFMESP (IN)POWER EF-1PANASONIC FV-08VQ5 ELEVATOR EQUIPMENT ROOM ELEVATOR EQUIPMENT ROOM CEILING651,0890.2514.5 W0.410.4 INTEGRAL BACKDRAFT DAMPER, INTERLOCK WITH WALL MOUNTED TIMER SWITCH.EF-2PANASONIC FV-08VQ5MAID CLOSETMAID CLOSETCEILING651,0890.2514.5 W0.410.4INTEGRAL BACKDRAFT DAMPER, INTERLOCK WITH WALL SWITC H EF-3ENERVEX BESB 500 COMMERCIAL DRYERS MECHANICAL ROOFROOF3,6801,7200.503 HP227 MEC 18 EXHAUST CONTROLLER WITH XTP SENSOR AND DUCT PROBE, ABB ACH 350 VARIABLE FREQUENCY DRIVE, INTERLOCK WITH DRYERS TO PREVENT DRYERS STARTING UNLESS THE FAN IS RUNNING.EF-4 PANASONIC FV-11VHL1 BATH EXHAUST CONDO BATHROOMS CEILING961,2600.251450 W<131.5 INTERLOCK EXHAUST FAN WITH MANUAL ON/OFF SWITCH, INTERLOCK HEATER W/ WALL MOUNTED THERMOSTAT.120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 208 / 3 / 60 NOISE LEVEL (SONES)SERVICE TOTAL CFM FAN RPM ESP (IN)OPER. WT. (LBS)TYPE EXHAUST FAN SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.REMARKS ELECTRICAL DATA V / PH / Hz LOCATION OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.USE MOUNTING LOCATION STYLE FRAME TYPE FINISH MAX SOUND LVL (NC)REMARKS APRICE - 22SUPPLYDUCT 3/4" DOUBLE DEFLECTION GRILLE DUCT MOUNT COORD. W/ ARCH 25STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS.BPRICE - SPDSUPPLYCEILING SQUARE PLAQUE DIFFUSER LAY IN COORD. W/ ARCH 25STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS.CPRICE - 530RETURNSIDEWALL 3/4" 45° SINGLE DEFLECTION GRILLE SURFACE MOUNT COORD. W/ ARCH 25STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS.DPRICE - 80RETURNCEILINGEGGCRATELAY IN COORD. W/ ARCH 25STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS.AIR DEVICE SCHEDULE INOUTMINMAXVPHHZ B-1 P-K MACH SERIES C-750 SNOWMELT750.0598.5414373301051451201606"695 UNIT TAG MANUFACTURER & MODEL NO.STACK DIA. (IN)OPER. WT. (LBS) BOILER SCHEDULE RELIEF PRESS (PSI)EWT (°F)LWT (°F)ELECTRICAL DATA SERVICE CAPACITY (MBH) @ 8000' ASL GAS PRESSURE (IN WC)MAX PD (FT)FLOW (GPM)REMARKS OR EQUIVALENT V / PH / HzPOWER P-1 GRUNDFOS UPS 40-40F SNOWMELT BOILERMECHANICAL ROOMINLINE37.06.0115/1/60150 WSPEED 2 P-2 GRUNDFOS UPS 40-160F SNOWMELT MANIFOLDS 1-4MECHANICAL ROOMINLINE52.926.0115/1/60890 WSPEED 3 UNIT TAG MANUFACTURER & MODEL NO.REMARKS PUMP SCHEDULE SERVICELOCATIONTYPEGPM TOTAL HEAD (FT)ELECTRICAL DATA 11WIRSBO hePEXWEST WALKWAY NORTH975125CONCRETE5/8962171.9311.613.2650% PROPYLENE GLYCOL 22WIRSBO hePEXWEST WALKWAY MIDDLE1,070125CONCRETE5/8972041.8212.811.2150% PROPYLENE GLYCOL 33WIRSBO hePEXWEST WALKWAY SOUTH1,540125CONCRETE5/89102051.8318.311.4450% PROPYLENE GLYCOL 44WIRSBO hePEXBREEZEWAY675125CONCRETE5/8951801.618.17.98 54WIRSBO hePEXLOWER LEVEL PATIOS210125CO NCRETE5/8921401.002.12.66 PD (FT)MANIFOLD TAG REMARKS TUBE SPACING (IN)NUMBER LOOPS LOOP LENGTH GPM/ LOOP 3 LOOPS FOR THE BREEZEWAY, 2 LOOPS FOR LOWER LEVEL PATIOS, 2 LOOPS FOR FUTURE. 50% PROPYLENE GLYCOL SNOWMELT SCHEDULE ZONE TAG MANUFACTURER & MODEL NO.SERVICE AREA (SQ FT)BTUH/ SQ FT SURFACE FINISH TUBE DIA (IN)GPM/ ZONE (MBH)EATLATEWTLWTGPMHD (FT)HC-1MCQUAY 5WB0701C HOUSEKEEPING OFFICE HOUSEKEEPING CLOSET DUCT MOUNTED30012" X 12"30010.14.950.070.01801600.50.127 INTERLOCK 2-WAY VALVE WITH 7 DAY PROGRAMMABLE WALL MOUNTED THERMOSTAT.HC-2MCQUAY 5WH1002BDRYER MAKE UPBREAK ROOMDUCT MOUNTED80024" X 12"40020.152.0-20.060.01801402.70.150INTERLOCK 2-WAY VALVE WITH DISCHARGE AIR SENSOR SET AT 70 DEG.HEATING COIL SCHEDULE OR EQUIVALENT SERVICELOCATION ROWS REMARKS UNIT TAG MANUFACTURER & MODEL NO.TYPE AIRFLOW THROUGH COIL (CFM)AIR P.D. (IN. WC)HEATING COIL DATA COIL DIMENSIONS (H X L)OPER. WEIGHT (LBS)FACE VELOCITY (FPM)UNIT TAG MANUFACTURER & MODEL NO.SERVICELOCATIONCFMSIZE (W"xH")FACE VELOCITY (FPM)PRESSURE DROP (IN SP)% FREE AREA FRAME TYPE FINISHREMARKS L-1RUSKIN - ELF6375DX MECHANICAL ROOM MECHANICAL ROOM VAULT 7,53060x369200.153%COORD. W/ ARCH COORD. W/ ARCH.BIRD SCREEN LOUVER SCHEDULE OR EQUIVALENT TOTAL CFM ESP (IN)RPMHPL(IN)H(IN)W(IN)SF-1ENERVEX SFTA 16LAUNDRYLAUNDRYTUBE-AXIAL36800.3017501 19191953 EBC30 MODULATING PRESSURE CONTROLLER, VARIABLE FREQUENCY DRIVE, VIBRATION ISOLATORS, FLEXIBLE DUCT CONNECTORS.SF-2COOK 135SQN-BBOILERS MECHANICAL ROOM INLINE12000.251087 1/48.7221818146 VIBRATION ISOLOATORS, FLEXIBLE DUCT CONNECTORS, INTERLOCK OPERATION WITH BOILERS TO PREVENT THE BOILERS FROM FIRING WHEN THE FAN IS NOT RUNNING.SF-3COOK 120SQN-B RESIDENTIAL DRYERS BREAK ROOMINLINE8000.251087 1/68221818100 VIBRATION ISOLOATORS, FLEXIBLE DUCT CONNECTORS, INTERLOCK OPERATION WITH DRYERS TO PREVENT THE DRYERS FROM RUNNING WHEN THE FAN IS NOT RUNNING.120 / 1 / 60 120 / 1 / 60 SUPPLY FAN SCHEDULE OR EQUIVALENT DIMENSIONS LOCATION V/PH/HZ 208 / 3 / 60 ELECTRICAL DATA NOISE LEVEL (SONES) SERVICE OPER. WT. (LBS)REMARKS UNIT TAG MANUFACTURER &MODEL NO.TYPE SUPPLY FAN L (IN)W (IN)H (IN)W GF-1AXIOM - MF300 SNOWMELT SYSTEM MECHANICAL ROOM 1711.7511.7536.000.750160-120 / 1 / 60 DIMENSIONS GLYCOL FEEDER SCHEDULE UNIT TAG MANUFACTURER & MODEL NO.LOCATION OPER. WEIGHT (LBS)ELECTRICAL DATA FREE FLOW (GPM)SERVICELOCATION OR EQUIVALENT TANK VOLUME (GAL)V / PH /Hz DIA (IN)H (IN)ET-1 AMTROL EXTROL SX-30V SNOWMELT SYSTEM MECHANICAL ROOM 14.011.31524121230130120-LOCATION RELIEF PRESSURE (PSI)WATER TEMP (°F)OPER. WEIGHT (LBS)EXPANSION TANK SCHEDULE OR EQUIVALENT LOCATION TANK VOLUME (GAL)DIMENSIONS ACCEPT VOLUME (GAL)CHARGE PRESSURE (PSI)OPERAT. PRESSURE (PSI)UNIT TAG MANUFACTURER & MODEL NO.SERVICE Received By David Rhoades at 4:37 pm, Mar 28, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) 4/10/12
Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/10/12